• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 144
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 149
  • 66
  • 42
  • 36
  • 35
  • 35
  • 31
  • 25
  • 23
  • 21
  • 21
  • 21
  • 21
  • 19
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Rastreamento visual e refrativo em crianças pré-escolares de 4 a 6 anos de idade / Visual acuity and refractive screenings in preschool children between 4-6 years old

Flávio Fernandes Villela 13 December 2016 (has links)
INTRODUÇÃO: O relacionamento com o mundo exterior é feito fundamentalmente através da visão, de modo que qualquer anormalidade na função visual das crianças pré-escolares pode levar à dificuldade no aprendizado e no relacionamento social, assim como queda de rendimento nas atividades físicas e intelectuais. O Sistema Único de Saúde ainda não se estruturou para o atendimento oftalmológico do pré-escolar e os rastreamentos visuais realizados nas escolas são, às vezes, a única chance de detecção dos problemas visuais nesta população. OBJETIVOS: Detectar erros de refração não corrigidos e fatores causadores de ambliopia em uma população de préescolares com 4 - 6 anos de idade, por meio de rastreamento visual (medida da AV com a tabela de Snellen) e refrativo (medida do erro refrativo sem e com cicloplegia com o Spot(TM) Vision Screener). MÉTODOS: 97 crianças préescolares matriculadas em creches municipais e estaduais foram submetidas a rastreamento visual (ponto de corte: AV monocular <= 0,7 e/ou diferença duas linhas de Snellen entre os olhos) e rastreamento refrativo (ponto de corte: hipermetropia >= 3,00 D, miopia >= 0,75 D e astigmatismo >= 0,75 D). Todas as crianças foram submetidas a exame oftalmológico completo e mensuração do erro refrativo com cicloplegia com o refrator automático Topcon KR 8000. RESULTADOS: O método de rastreamento visual com tabela optométrica de Snellen apresentou valores de sensibilidade e especificidade, respectivamente, 58,6% e 64,7%. O método de rastreamento refrativo com Spot(TM) Vision Screener apresentou valores de sensibilidade e especificidade, respectivamente, 92,8% e 35,2% (sem cicloplegia) e 96,4% e 29,4% (com cicloplegia). Os percentuais estimados do não encaminhamento para exame oftalmológico completo das crianças com erros de refração acima do ponto de corte estabelecido foram: 46,4% para o rastreamento visual, 17,9% para o rastreamento refrativo com Spot(TM) sem cicloplegia e de 3,6% com o Spot(TM) com cicloplegia. CONCLUSÃO: Na população avaliada, o método de triagem refrativa pelo Spot(TM) Vision Screener com cicloplegia foi o mais efetivo / BACKGROUND: Contacting the outside world is fundamentally made through vision, so that any abnormalities in visual function of preschool children can lead to difficulty in learning and social networking, as well as income decline in physical and intellectual activities. Brazilian Health System (SUS) has not yet structured to preschool eye care and visual scans performed in schools are sometimes the only chance of detection of visual problems in this population. PURPOSES: Detect uncorrected refractive errors and factors that lead to ambliopia in a population of preschool children 4-6 years of age by visual screening (as visual acuity with the Snellen chart) and refractive (measurement of refractive error, without cicloplegia and under cicloplegia, by photoscreener Spot(TM) Vision Screener). METHODS: 97 preschool children enrolled in state and municipal schools were subjected to visual screening (cut-off: monocular visual acuity <= 0.7 and / or difference of two lines in Snellen chart between both eyes) and refractive screening (cut-off: hyperopia >= 3.00 D, myopia >= 0.75 D and astigmatism >= 0.75 D). All children underwent complete eye examination and measurement of refractive errors under cycloplegia with auto-refractor Topcon KR 8000. RESULTS: Visual screening method using chart Snellen had values of sensitivity and specificity, respectively, 58.6% and 64.7%. Refractive screening method using photoscreener Spot(TM) Vision Screener showed values of sensitivity and specificity, respectively, 92.8% and 35.2% (without cycloplegia), and 96.4% and 29.4% (under cycloplegia). The estimated percentage of non-referral to complete ophthalmologic examination of children with refractive errors above the cut-off point were 46.4% for the visual screening, 17.9% for the refractive screening with Spot(TM) without cycloplegia and 3.6 % with Spot(TM) under cycloplegia. CONCLUSION: In this population, the refractive screening method by Spot(TM) Vision Screener under cycloplegia was the most effective
132

Rastreamento visual e por photoscreener em escolares do primeiro ano do ensino fundamental / Visual acuity screening and photoscreening in school-children at the first grade of elementary school

Daniela Lima de Jesus 29 September 2015 (has links)
INTRODUÇÃO: Aproximadamente 20% das crianças brasileiras em idade escolar apresentam algum problema oftalmológico e cerca de 95% dos distúrbios poderiam ser evitados ou minorados com promoção de saúde e assistência. A triagem visual é realizada por agentes comunitários de saúde, professores e alfabetizadores. Apesar do treinamento que os professores recebem, muitas crianças são dispensadas na triagem realizada nos serviços especializados e ainda existe um alto índice de absenteísmo, evidenciando-se a necessidade de melhorar a gestão dos recursos humanos e financeiros envolvidos no rastreamento visual e refrativo de escolares do ensino fundamental. OBJETIVOS: O estudo buscou comparar o rastreamento visual com corte de acuidade visual monocular, sem correção, <= 0,7, corte <= 0,6, medida de acuidade visual binocular e corte <= 0,7 e rastreamento refrativo com Spot Vision ScreeningTM PediaVision (SPOT). O segundo objetivo deste estudo foi avaliar a performance do SPOT como auto-refrator. MÉTODOS: Durante o Projeto Visão do Futuro, ocorrido em 2012, no HCFMUSP, avaliamos 1554 crianças, que preencheram os critérios de inclusão do estudo e destas, 148 foram submetidas ao photoscreening. RESULTADOS: A adoção de corte <= 0,6 no rastreamento visual monocular reduziria em 29% o número de crianças encaminhadas para avaliação oftalmológica e a triagem binocular com corte <= 0,7 em 41,1%, porém 61 casos de ambliopia deixariam de ser diagnosticados. O SPOT apresentou sensibilidade em detectar erro refracional com necessidade de prescrição de 73,3% e especificidade de 93,18% e, em média, a diferença da refração do Spot com a refração clínica subjetiva foi de + 0,63 DE com -0,33 DC no eixo de 4°, para o olho direito de cada paciente. CONCLUSÕES: As mudanças de corte para 0,6 e binocular 0,7 reduzem consideravelmente o número de avaliações, porém, a última deixa de diagnosticar parcela importante das crianças amblíopes. O SPOT apresentou bons índices de sensibilidade e especificidade no rastreamento refrativo em escolares e os valores de refração obtidos com este equipamento assemelham-se clinicamente aos valores de refração clínica subjetiva / BACKGROUND: Approximately 20% of brazilian children of school age have some eye problem and about 95% of the disorders could be prevented or reduced with health promotion and care. The visual screening is performed by community health agent and teachers. Despite training that teachers receive, many children are over-referred and also there\'s a high index of absence students, highlighting the need to improve the management of human and financial resources involved in visual and refractive screening of elementary school. PURPOSES: The present study aimed to compare visual screening by monocular visual acuity with cut-off of 0,7, 0,6, binocular visual acuity and cut-off 0,7 and photoscreening by Spot Vision ScreeningTM PediaVision (SPOT). The second objective of this study was to evaluate the performance of the Spot as auto-refractor. METHODS: During the Program \"Visão do Futuro\", in 2012, at HCFMUSP, 1554 children that met the inclusion criteria were examined, 148 of these were photoscreened. RESULTS: The adoption of cut-off <= 0.6 in monocular visual screening would reduce by 29% the number of children referred for ophthalmic evaluation and binocular screening with cutting <= 0.7 to 41.1%, however 61 cases of amblyopia would not be diagnosticated. SPOT had a sensitivity to detect refractive error requiring prescription of 73.3% and specificity of 93.18%. The mean difference between refraction obtained by Spot and clinical subjective refraction was of +0.63 SD combined with -0,33 CD in the 4° axis for right eye of each patient. CONCLUSIONS: Reducing cut-off in monocular visual acuity to 0.6 or 0.7 binocular considerably reduce the number of evaluations, however, the last leaves to diagnose significant portion of amblyopic children. The SPOT showed good levels of sensitivity and specificity in refractive screening of school children and refraction values obtained with this equipment are clinically similar to the values of subjective clinical refraction
133

Investigação experimental e modelo teórico para o índice de refração não-linear da linha D2 do césio

Araújo, Michelle Oliveira de 23 July 2013 (has links)
Made available in DSpace on 2015-05-14T12:14:09Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 5247280 bytes, checksum: a825d4cf1e9d423d3daa9794ddd2962e (MD5) Previous issue date: 2013-07-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The response of a material to an incident radiation can be described in terms of the susceptibility of the medium. In an atomic vapor, this susceptibility strongly depends on the frequency of the radiation and can vary over several orders of magnitude near the resonance. When a material is illuminated by light whose electric field is intense, the Kerr effect may become significant, showing a linear variation of the refractive index as a function of the intensity of the laser beam. Several techniques allow the measurement of this nonlinear effect. One of the simplest and most accurate is the z-scan technique. It consists in moving the medium to be probed along the axis of a focused laser beam. The transmittance through an aperture is measured as a function of the cell position and the obtained curve allows one to determine the nonlinear refractive index (n2) of the material. In this work, we investigate the nonlinear refractive index of a vapor of cesium atoms. We used the z-scan technique for various detunings around the Cs D2 transition (wavelength at 852 nm). To monitor the frequency of the laser, we simultaneously used an auxiliary saturated absorption setup and a Fabry-Perot analyzer. Through simple relationships between n2 and the aperture transmittance, we obtained a value for n2 as a function of the laser detuning. A theoretical model was developed to be compared to our experimental results. We used the density matrix formalism to calculate n2, taking into account the velocity distribution of the atoms in the calculation of the matrix elements. We started by treating the atoms as two-level systems, which allows us to test different limits of velocity integration. We then carried out a more realistic model for the D2 line of Cs, considering one fundamental level and three excited levels. We showed that for each hyperfine transition, the third-order fundamental-excited coherence depends on the population of the excited states as well as on the coherence created between the excited levels. To our knowledge, our experimental results are the first measurements of n2 for a cesium vapor, using the z-scan technique. The measured values of n2 are consistent with our theoretical calculations. / A resposta de um meio material à radiação incidente pode ser descrita em termos da susceptibilidade ótica desse meio. Em vapores atômicos, essa susceptibilidade depende fortemente da freqüência da radiação e pode variar, em torno da ressonância, por várias ordens de grandeza. Quando um material é iluminado por um feixe de luz cujo campo elétrico é muito intenso, evidencia-se o efeito Kerr, ou seja, o próprio índice de refração do material varia linearmente com a intensidade do feixe laser. Para medir esse efeito não linear da polarização do material, existem varias técnicas na literatura. Uma das mais simples e precisa é a varredura z (z-scan). O z-scan consiste em deslocar o meio a ser estudado ao longo do eixo de um feixe laser focalizado. Mede-se então a transmitância através de uma abertura, em função da posição da célula. A partir dessa curva de transmitância, é possível determinar o índice de refração não linear do material. Neste trabalho, investigamos a dependência espectral do índice de refração não linear do vapor atômico de césio. Realizamos experimentos com a técnica z-scan para várias dessintonizações na linha D2 (comprimento de onda de 852 nm). O monitoramento da freqüência do laser é feito através de uma montagem auxiliar de absorção saturada e de uma cavidade Fabry-Pérot. Utilizando relações simples entre n2 e a transmitância na abertura, obtivemos um valor de n2 para cada dessintonização. Para interpretar os resultados experimentais, usamos o formalismo de matriz densidade para calcular teoricamente o n2. No cálculo dos elementos da matriz densidade, deve-se levar em consideração a distribuição de velocidades dos átomos. Iniciamos nosso modelo tratando os átomos como sistemas de dois níveis, com o objetivo de compreender os diferentes limites da integração em velocidade. Em seguida passamos para um modelo mais realista para a linha D2 do Cs envolvendo um nível fundamental e três excitados. Mostramos que, para cada transição hiperfina, a coerência fundamental-excitada de terceira ordem depende de efeito de população dos estados excitados e da coerência criada entre eles. Nossos resultados experimentais são, até onde sabemos, as primeiras medidas usando z-scan para a obtenção do indice de refração de vapor de césio. Os valores medidos de n2 são condizentes com os nossos cálculos teóricos.
134

Aplicação de transdutores óticos para a monitoração da qualidade de biocombustíveis / Application of optical transducers for biofuels quality monitoring

Kawano, Marianne Sumie 07 October 2015 (has links)
CAPES; CNPq; Fundação Araucária / No presente trabalho foram estudadas as respostas de sensores óticos baseados em rede de período longo em cascata (CLPG) na avaliação de biocombustíveis (biodiesel de soja e etanol) em diferentes situações de não conformidade, simulando casos de possíveis adulterações ou ainda falhas no processo de fabricação. Para tanto, os dispositivos serviram como transdutores de índice de refração das substâncias analisadas. Em uma das aplicações dos sensores foram avaliadas misturas entre biodiesel de soja e óleo de soja comercial, sendo observado o desempenho do sensor ótico ao longo de toda a faixa de concentração de óleo em biodiesel (0 – 100%) e, as características metrológicas foram calculadas para três faixas de operação do sistema, abrangendo diferentes faixas de concentrações. Para as faixas 1 a 3, a sensibilidade variou de 0,06 – 0,30 nm / % v/v e a resolução de 0,17 a 0,03 % / v/v. Com o intuito de comparar resultados, as mesmas amostras de biodiesel-óleo foram avaliadas com técnicas de ultrassom, obtendo para esse, sensibilidade de 0,70 m/s / % v/v e resolução de 0,4 %. Outra situação estudada foi com relação às misturas entre biodiesel de soja e metanol e a resposta do sensor ótico apresentou resolução de 0,007 – 0,001 % / v/v. Por meio dessas respostas pôde-se desenvolver um método analítico no qual se utiliza o sensor ótico para a determinação de constituintes em misturas ternárias (biodiesel-óleo-metanol), desde que associando à operação do sensor a variação de temperatura das amostras. Em outra parte do trabalho, o sensor ótico também foi empregado na avaliação de etanol. A resposta do sensor para misturas etanol-metanol apresentou resolução de 0,19 % / v/v, enquanto que, a avaliação dessas mesmas substâncias utilizando o ultrassom, apresentou resolução de 0,26 % / v/v. Outra situação analisada com o sensor ótico, para a análise da conformidade do etanol combustível, foram amostras apresentando misturas ternárias (etanol-metanol-água) em que se fez necessária a avaliação dessas misturas por meio de um refratômetro de Abbe e medidas de densidade. Os resultados encontrados apresentaram-se promissores ao relacionar os dados refratométricos em relação às densidades obtidas para cada amostra, uma vez que, apenas um desses parâmetros não seria capaz de identificar a conformidade do produto. Foi possível então determinar, dentre todos os resultados, uma região de conformidade para o etanol combustível. / In the present work were studied the responses of the optical sensors based on cascaded long period gratings (CLPG) to evaluate biofuels (soy biodiesel and ethanol) in different situations of non-compliance, simulating cases of possible tampering or failures in the process of manufacturing. To this end, the devices served as refractive index transducers of the analyzed substances. One of the applications of the sensors were evaluate mixtures of soybean biodiesel and commercial soybean oil, observing the performance of the optical sensor over the whole range of biodiesel oil concentration (0 - 100%) and the metrological characteristics were calculated for three system operating ranges covering different concentration ranges. In lanes 1 through 3, the sensitivity ranged from 0.06 to 0.30 nm /% v / v and the resolution from 0.17 to 0.03% / v / v. In order to compare the results, the same samples of biodiesel oil, were assessed by ultrasound techniques for obtaining this, a sensitivity of 0.70 m / sec / v / v% and resolution of 0.4%. Another situation studied envolved mixtures of soybean biodiesel and methanol and the response of the optical sensor showed resolution from 0.007 to 0.001% / v / v. Through these responses could be developed an analytical method which uses the optical sensor for the determination of constituents of ternary mixtures (biodiesel - soybean oil - methanol) associating to the sensor the right temperature of the samples. Another part of the work, the optical sensor was used in the evaluation of ethanol. The sensor response for ethanol-methanol mixtures showed resolution of 0.19% / v / v, while the evaluation of those substances using ultrasound, showed resolution of 0.26% / v / v. Another situation observed using the optical sensor was the analysis of ethanol fuel with samples having ternary mixtures (ethanol-methanol-water) in which the evaluation of these mixtures by means of a refractometer Abbe and density measurements made necessary. The results presented in these analyses are promising when related the refractometric to densities datas obtained for each sample, since only one of these parameters would not be able to identify the product conformity. It was then possible to determine, among all results, a compliance region for ethanol fuel.
135

Aplicação de transdutores óticos para a monitoração da qualidade de biocombustíveis / Application of optical transducers for biofuels quality monitoring

Kawano, Marianne Sumie 07 October 2015 (has links)
CAPES; CNPq; Fundação Araucária / No presente trabalho foram estudadas as respostas de sensores óticos baseados em rede de período longo em cascata (CLPG) na avaliação de biocombustíveis (biodiesel de soja e etanol) em diferentes situações de não conformidade, simulando casos de possíveis adulterações ou ainda falhas no processo de fabricação. Para tanto, os dispositivos serviram como transdutores de índice de refração das substâncias analisadas. Em uma das aplicações dos sensores foram avaliadas misturas entre biodiesel de soja e óleo de soja comercial, sendo observado o desempenho do sensor ótico ao longo de toda a faixa de concentração de óleo em biodiesel (0 – 100%) e, as características metrológicas foram calculadas para três faixas de operação do sistema, abrangendo diferentes faixas de concentrações. Para as faixas 1 a 3, a sensibilidade variou de 0,06 – 0,30 nm / % v/v e a resolução de 0,17 a 0,03 % / v/v. Com o intuito de comparar resultados, as mesmas amostras de biodiesel-óleo foram avaliadas com técnicas de ultrassom, obtendo para esse, sensibilidade de 0,70 m/s / % v/v e resolução de 0,4 %. Outra situação estudada foi com relação às misturas entre biodiesel de soja e metanol e a resposta do sensor ótico apresentou resolução de 0,007 – 0,001 % / v/v. Por meio dessas respostas pôde-se desenvolver um método analítico no qual se utiliza o sensor ótico para a determinação de constituintes em misturas ternárias (biodiesel-óleo-metanol), desde que associando à operação do sensor a variação de temperatura das amostras. Em outra parte do trabalho, o sensor ótico também foi empregado na avaliação de etanol. A resposta do sensor para misturas etanol-metanol apresentou resolução de 0,19 % / v/v, enquanto que, a avaliação dessas mesmas substâncias utilizando o ultrassom, apresentou resolução de 0,26 % / v/v. Outra situação analisada com o sensor ótico, para a análise da conformidade do etanol combustível, foram amostras apresentando misturas ternárias (etanol-metanol-água) em que se fez necessária a avaliação dessas misturas por meio de um refratômetro de Abbe e medidas de densidade. Os resultados encontrados apresentaram-se promissores ao relacionar os dados refratométricos em relação às densidades obtidas para cada amostra, uma vez que, apenas um desses parâmetros não seria capaz de identificar a conformidade do produto. Foi possível então determinar, dentre todos os resultados, uma região de conformidade para o etanol combustível. / In the present work were studied the responses of the optical sensors based on cascaded long period gratings (CLPG) to evaluate biofuels (soy biodiesel and ethanol) in different situations of non-compliance, simulating cases of possible tampering or failures in the process of manufacturing. To this end, the devices served as refractive index transducers of the analyzed substances. One of the applications of the sensors were evaluate mixtures of soybean biodiesel and commercial soybean oil, observing the performance of the optical sensor over the whole range of biodiesel oil concentration (0 - 100%) and the metrological characteristics were calculated for three system operating ranges covering different concentration ranges. In lanes 1 through 3, the sensitivity ranged from 0.06 to 0.30 nm /% v / v and the resolution from 0.17 to 0.03% / v / v. In order to compare the results, the same samples of biodiesel oil, were assessed by ultrasound techniques for obtaining this, a sensitivity of 0.70 m / sec / v / v% and resolution of 0.4%. Another situation studied envolved mixtures of soybean biodiesel and methanol and the response of the optical sensor showed resolution from 0.007 to 0.001% / v / v. Through these responses could be developed an analytical method which uses the optical sensor for the determination of constituents of ternary mixtures (biodiesel - soybean oil - methanol) associating to the sensor the right temperature of the samples. Another part of the work, the optical sensor was used in the evaluation of ethanol. The sensor response for ethanol-methanol mixtures showed resolution of 0.19% / v / v, while the evaluation of those substances using ultrasound, showed resolution of 0.26% / v / v. Another situation observed using the optical sensor was the analysis of ethanol fuel with samples having ternary mixtures (ethanol-methanol-water) in which the evaluation of these mixtures by means of a refractometer Abbe and density measurements made necessary. The results presented in these analyses are promising when related the refractometric to densities datas obtained for each sample, since only one of these parameters would not be able to identify the product conformity. It was then possible to determine, among all results, a compliance region for ethanol fuel.
136

Estudo da previsão de propriedades do biodiesel utilizando espectros de infravermelho e calibração multivariada / Study of prediction of biodiesel properties using infrared spectra and multivariate calibration

Camilla Lima Cunha 25 February 2014 (has links)
O biodiesel tem sido amplamente utilizado como uma fonte de energia renovável, que contribui para a diminuição de demanda por diesel mineral. Portanto, existem várias propriedades que devem ser monitoradas, a fim de produzir e distribuir biodiesel com a qualidade exigida. Neste trabalho, as propriedades físicas do biodiesel, tais como massa específica, índice de refração e ponto de entupimento de filtro a frio foram medidas e associadas a espectrometria no infravermelho próximo (NIR) e espectrometria no infravermelho médio (Mid-IR) utilizando ferramentas quimiométricas. Os métodos de regressão por mínimos quadrados parciais (PLS), regressão de mínimos quadrados parciais por intervalos (iPLS), e regressão por máquinas de vetor de suporte (SVM) com seleção de variáveis por Algoritmo Genético (GA) foram utilizadas para modelar as propriedades mencionadas. As amostras de biodiesel foram sintetizadas a partir de diferentes fontes, tais como canola, girassol, milho e soja. Amostras adicionais de biodiesel foram adquiridas de um fornecedor da região sul do Brasil. Em primeiro lugar, o pré-processamento de correção de linha de base foi usado para normalizar os dados espectrais de NIR, seguidos de outros tipos de pré-processamentos que foram aplicados, tais como centralização dos dados na média, 1 derivada e variação de padrão normal. O melhor resultado para a previsão do ponto de entupimento de filtro a frio foi utilizando os espectros de Mid-IR e o método de regressão GA-SVM, com alto coeficiente de determinação da previsão, R2Pred=0,96 e baixo valor da Raiz Quadrada do Erro Médio Quadrático da previsão, RMSEP (C)= 0,6. Para o modelo de previsão da massa específica, o melhor resultado foi obtido utilizando os espectros de Mid-IR e regressão por PLS, com R2Pred=0,98 e RMSEP (g/cm3)= 0,0002. Quanto ao modelo de previsão para o índice de refração, o melhor resultado foi obtido utilizando os espectros de Mid-IR e regressão por PLS, com excelente R2Pred=0,98 e RMSEP= 0,0001. Para esses conjuntos de dados, o PLS e o SVM demonstraram sua robustez, apresentando-se como ferramentas úteis para a previsão das propriedades do biodiesel estudadas / Biodiesel has been widely used as a renewable energy source which contributes to the mineral diesel decrease demand. Therefore, there are several properties that must be monitored in order to produce and distribute biodiesel with the required quality. In this work, the biodiesel physical properties such as specific mass, refractive index and cold filter plugging point were measured and associated with near infrared spectroscopy (NIR) and mid-Infrared spectroscopy (mid-IR) spectra using chemometric tools. The Partial Least Squares Regression (PLS), Interval Partial Least Squares Regression (iPLS), and Support Vector Machines Regression (SVM) with variable selection by Genetic Algorithm (GA) methods were used to model the aforementioned properties. The biodiesel samples were synthesized from different sources such as canola, sunflower, corn, and soybean. Additional biodiesel samples were purchased from a Brazil South Region supplier. Firstly, the preprocessing baseline correction was used to normalize the NIR spectral data, following others preprocessing types were applied in such as the mean center, the first derivative and standard normal variate. The best result for predicting the cold filter plugging point was using Mid-IR spectra and GA-SVM regression method, with high coefficient determination of prediction, R2Pred = 0.94 and low value of the Root Mean Square Error of Prediction, RMSEP (C) = 0.7. For the specific mass prediction model, the best result was obtained using the Mid-IR spectrums and PLS regression, with the R2Pred = 0.98 and RMSEP (g/cm3) = 0.0002. As for a prediction model for the refractive index, the best result was obtained using the Mid-IR spectrums and PLS regression, with the R2Pred = 0.98 and RMSEP = 0.0001. For these datasets, the PLS and SVM models demonstrated theirs robustness, presenting themselves as useful tools for the biodiesel properties prediction studied
137

Propriedades ópticas não-lineares de oligômeros de anilina / Nonlinear optical properties of aniline oligomers

Paulo Licênio Franzen 29 October 2002 (has links)
Apresentamos os resultados do estudo das não-linearidades ópticas de origem eletrônica de duas moléculas da classe dos oligômeros de anilina: o dímero e o tetrâmero. Foram medidas quatro concentrações de tetrâmero, puras e também dopadas em 33 e 100%; uma de dímero pura e outra dopada em 100%. As soluções foram preparadas usando dimetil-sulfóxido (DMSO) como solvente e a dopagem foi realizada com ácido clorídrico. As amostras foram caracterizadas por medidas de absorção linear e fluorescência antes das medidas não-lineares. Obtivemos os valores da primeira hiperpolarizabilidade (?) para todas as amostras, o índice de refração não-linear (n2) do tetrâmero dopado e não dopado, e a absorção não-linear em função da intensidade e da concentração do tetrâmero. As medidas foram realizadas através das técnicas de Varredura-Z, absorção não-linear e espalhamento Hiper-Rayleigh. Os resultados foram interpretados em termos da comparação entre diferentes estados de dopagem e da variação da seção de choque do estado fundamental para o primeiro excitado. / We report on the study of electronic optical non linearities in two aniline oligomers: dimer and the tetramer. Four tetramer concentrations were measured, pure and also 33 and 100% doped; one of dimer non doped another 100% doped. The solutions were prepared using dimethyl sulfoxide (DMSO) as solvent and the doping was performed with hydrochloric acid. The samples were characterized by measurements of linear absorption and fluorescence. We obtained the values of the first hyperpolarizability (?) for all samples, the non linear index of refraction (n2) for non doped and doped tetramer, and the non linear absorption in function of intensity and concentration of the tetramer. The measurements were accomplished through the techniques of Z-Scan, non linear absorption and Hyper-Rayleigh Scattering. The results were interpreted in terms of the comparison among different doping states and of the variation of cross-section for the transition from ground to the first excited states.
138

Estudo de propriedades ópticas de moléculas de chalconas

Santos, Francisco de Assis 28 July 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work reports on the optical properties of chalcones molecules in solution, using methanol as solvent. For the characterization of the linear optical properties, were obtained absorbance spectra. While for the characterization of the nonlinear optical properties, it has been used techniques hyper-Rayleigh scattering and Z-scan. Using hyper-Rayleigh scattering technique, were determined the first hyperpolarizabilities of the molecules studied. With the Z-scan technique, we could obtain the two-photon absorption spectra at several wavelengths in the range of 480 to 790 nm. From the two-photon absorption spectra were possible to determine the coefficients of two-photon absorption and their respective cross section. The results help to understand the effects of substituents added to the basic structure of chalcones in both linear optical properties as nonlinear. / Neste trabalho, estudamos as propriedades ópticas de moléculas de chalconas em solução, usando o metanol como solvente. Para a caracterização das propriedades ópticas lineares foram determinados os espectros de absorção. Na caracterização das propriedades ópticas não lineares foram utilizadas as técnicas de espalhamento hiper-Rayleigh e de varredura-Z. Utilizando a técnica de espalhamento hiper-Rayleigh foram determinadas as primeiras hiperpolarizabilidades das moléculas estudadas. Com a técnica de varredura-Z conseguimos obter os espectros de absorção de dois fótons em vários comprimentos de onda no intervalo dos 480 aos 790 nm. A partir dos espectros de absorção de dois fótons foi possível determinar o coeficiente da absorção de dois fótons e sua respectiva seção de choque. Os resultados ajudam a compreender os efeitos de substituintes, adicionados à estrutura básica das chalconas, tanto nas propriedades ópticas lineares quanto não lineares.
139

Propriedades estruturais do material vitreo silica-titania produzido pelo metodo do aerosol em chama / Structural properties of silica-titania vitreous material produced by flame aerosol method

Nunes, Claudia Carvalho 25 February 2008 (has links)
Orientador: Carlos Kenichi Suzuki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-11T16:06:32Z (GMT). No. of bitstreams: 1 Nunes_ClaudiaCarvalho_M.pdf: 7074659 bytes, checksum: 4dec2d1e75a640341af023ba7541f5cb (MD5) Previous issue date: 2008 / Resumo: O sistema binário sílica titânia, SiO2-TiO2,apresenta grande interesse tecnológico devido as suas propriedades: ultra-baixo coeficiente de expansão térmico e alto índice de refração. As propriedades são dependentes da quantidade de dopante presente no material. A SiO2-TiO2 é usada na indústria de componentes fotônicos, tais como, lentes, micro-lentes, espelhos e fibras ópticas especiais. Um importante material óptico para litografia no extremo ultravioleta (EUVL) é caracterizado por concentrações próximas a 8 % em peso de TiO2, com estrutura amorfa e transparente num amplo espectro da região UV, visível e IV. A indústria óptico-eletrônica necessita de fibras ópticas sensoras com alto índice de refração. Este tipo de fibra pode ser obtido através da fabricação de uma fibra de SiO2-TiO2. Amostras com concentrações que variam de 1 a 14 % em peso TiO2 fabricadas pelo método do aerosol em chama foram caracterizadas quanto a suas propriedades estruturais e ópticas. As amostras com concentrações superiores a 7,5 % em peso apresentaram-se translúcidas ou opacas, e com estrutura octaédrica segundo dados de XANES (Absorção de Raios-X próximo à estrutura da borda). A difração de raios-X identificou a fase anatásio da titânia como estrutura octaédrica. Através de tratamentos térmicos a altas temperaturas em chama (> 1500 ºC) obtivemos amostras transparentes no visível, amorfa, contendo 8,2 % em peso. Foi obtido um material com índice de refração de 1,48 para concentração de 10 % em peso de TiO2. Portanto a SiO2-TiO2 é viável para a fabricação de uma fibra com alto índice de refração / Abstract: The binary SiO2-TiO2 system presents a great technological importance due to its special properties: ultra low thermal expansion and high refractive index. The properties depend on the amount of dopant present in material. The SiO2-TiO2 is used for the components of photonic industries, such as lenses, mirrors and special fiber optics. As an important optical material for extreme ultraviolet lithography (EUVL), it is characterized by concentrations of ~ 8 wt. % of TiO2, with amorphous structure and transparent for a large UV, visible and IR spectra. The optoelectronic industries needs optical fiber sensor that presents high refractive index. This kind of fiber can be produce by SiO2-TiO2 fiber production. Samples with concentrations varying in the range 1 to 14 wt. % TiO2 made by flame aerosol technique were characterized in terms of structural and optical properties. As-consolidated samples with concentrations up to 7.5 wt. % TiO2 presented itself translucent or opaque with octahedral structure, according to XANES data (X-ray absorption near-edge structure). The anatase phase of titania was identified by X-ray diffraction patterns. However, by high temperature flame heat treatments (> 1500 ºC), it was possible to obtain transparent SiO2-TiO2 materials in the visible range with concentration up to 8.2 wt. % TiO2. The material presents refractive index 1.48 with concentration about 10 wt. % TiO2. Therefore SiO2-TiO2 is feasible to fibers fabrication with high refractive index / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
140

Desenvolvimento de biosensores de membranas e caracterização da interação entre citocromo c e bicamadas híbridas por ressonância plasmônica de superfície / Development of membrane biosensors and characterization of the interactions between cytochrome c and hybrid bilayer membranes by Surface Plasmon Resonance

Tathyana Cristina Martins Cordeiro Tumolo 19 September 2008 (has links)
O objetivo deste trabalho foi desenvolver biosensores de membranas baseados na técnica de Ressonância Plasmônica de Superfície (SPR) e aplicá-los no estudo da interação do citocromo c (cit c) com modelos de membranas. SPR é uma técnica ótica, que através de medidas de variações de índice de refração (n) próximas a uma interface mensura com alta sensibilidade a adsorção ou ligação de moléculas. Inicialmente desenvolvemos um sistema de gradiente de fluxo acoplado ao SPR, denominado FIG-SPR, e demonstramos a determinação automatizada da variação de n em função da concentração (dn/dC) de diferentes compostos e biopolímeros. O desenvolvimento dos biosensores de membranas iniciou-se com o estudo dos fatores que afetam a formação de uma membrana de bicamada híbrida (HBM). HBMs são compostas de uma monocamada de alcanotiol adsorvida sobre o ouro, e sobre esta uma camada fosfolipídica. A formação da HBM depende da fusão de vesículas em superfícies hidrofóbicas e que não é bem compreendido no nível molecular. Nossos estudos mostraram que na presença de cálcio e espermina a formação da HBM é favorecida, de tal forma que a monocamada de fosfolipídio alcança valores de espessura próximos àqueles previstos, cerca de 20 &#197;\'. Além disso, mostramos que em soluções de baixa força iônica a camada lipídica não é homogênea. Demonstramos também que a presença de cálcio na concentração 150 mM diminui o tempo de formação da monocamada lipídica cerca de 14 vezes quando comparado ao tempo indicado na literatura. A homogeneidade da HBM e a carga superficial da mesma foram verificadas com a adsorção e a dissociação de cit c e de albumina bovina (BSA). Utilizando HBMs de composição lipídica variada demonstramos a adsorção e a dissociação de cit c induzida por cálcio em HBMs mistas, incluindo um modelo mimético da membrana mitocondrial interna (IMM) constituído de fosfatidilcolina, fosfatidiletanolamina e cardiolipina (PC/PE/CL) na proporção (4,5:3,5:2,0). Demonstramos que a adsorção de cit c nativo segue um perfil cooperativo e padrões esperados de variação de afinidade e cooperatividade em pHs 6,8, 7,4 e 8,0. Um modelo matemático foi desenvolvido para tratar as curvas de ligação de cit c, que é uma adaptação do modelo de Hill para adsorção de proteínas em superfícies. Os resultados de SPR juntamente com dados obtidos por Microscopia de Força Atômica (AFM) sugerem que a ligação cooperativa de cit c com HBM ocorre devido à reorganização das moléculas de CL e formação de domínios fosfolipídicos. O tratamento dos resultados cinéticos da dissociação de cit c por cálcio indica a existência de duas constantes de velocidade de dissociação (kd), sendo a primeira constante (kd1) relacionada à perda das interações eletrostáticas entre a proteína e a HBM, e a segunda (kd2) à perda das interações hidrofóbicas. Além disso, a dissociação do cit c do modelo estudado requer uma concentração mínima de cálcio de 30 &#181;M para se tornar significativa. O estudo da interação entre moléculas de cit c foto-oxidadas (citc405) e a HBM de PC/PE/CL sugerem que ela ocorre com menor afinidade, nos três pHs estudados, se comparados aos resultados com cit c nativo. Além disso, nossos resultados sugerem que o citc405 não é facilmente dissociado por cálcio devido à perda da cooperatividade na interação. Possíveis implicações em eventos celulares destas descobertas, como a liberação do cit c da IMM e a iniciação da apoptose, são discutidas / The aim of this work was to develop membrane biosensors based on Surface Plasmon Resonance (SPR) and to apply them to study the interactions between cytochrome c (cyt c) and model membranes. SPR is an optical technique that provides high-sensitivity measurements of refractive index (n), allowing the characterization of the adsorption and desorption of molecules near interfaces. Initially we developed a flow gradient system connected to SPR, which was called FIG-SPR, and demonstrated the automated determination of the concentration gradient of refractive index (dn/dC) of different materials and biopolymers. The development of the membrane biosensors was initiated by studying the factors that affect the formation of a hybrid bilayer membrane (HBM). HBMs are composed of two monolayers: an alcanethiol monolayer adsorbed on gold over which is adsorbed a layer of phospholipids. The formation of an HBM depends on the fusion of phospholipid vesicles on hydrophobic surfaces, a process that is not well understood at the molecular level. Our results showed that in the presence of calcium and spermine the complete formation of an HBM is facilitated, i.e., the phospholipid monolayer reaches the expected thickness of about 20&#197;\'. However, in low ionic strength solutions the lipid layer that is formed is not homogeneous. We have also demonstrated that in the presence of 150 mM of calcium the time necessary for the formation of the lipid monolayer is reduced 14 times when compared to the times suggested in the literature. The homogeneity of the HBM and its superficial charge were verified with the adsorption and desorption of cyt c and bovine serum albumine (BSA). The adsorption and desorption of cyt c in different HBMs were studied including a model of the internal mitochondrial membrane (IMM), which is made of phosphatidylcholine, phosphatidylethanolamine and cardiolipin (PC/PE/CL) in the ratio (4,5: 3,5: 2,0). We demonstrated that the adsorption of native cyt c follows a cooperative profile showing expected changes in affinity and cooperativity in different solution pHs of 6,8, 7,4 and 8,0. A mathematical model, which is an adaptation of the Hill model for adsorption of proteins in surfaces, was developed to treat the binding curves of cyt c. The results of SPR together with those obtained by Atomic Force Microscopy (AFM) suggested that the cooperative binding of cyt c in HBMs occurs due to the reorganization of CL molecules and formation of phospholipid domains. The kinetic results of the dissociation of cyt c induced by calcium indicates the existence of two velocity constants (kd), being the larger (kd1) related to the dissociation of cyt c interacting electrostatically with the HBM, and the smaller (kd2) related to the dissociation of cyt c interacting hydrophobically with the HBM. Moreover, the dissociation of cyt c from the HBM requires a minimum calcium concentration of 30 &#181;M. The study of the interaction between photo-oxidized cyt c molecules (cytc405) and the PC/PE/CL HBM suggests that it occurs with smaller affinity when compared with the results obtained with the native cyt c. Moreover, cytc405 is not easily dissociated by calcium due to the loss of the interaction cooperativity with the HBM. Possible implications of these discoveries in cellular events, such as the release of cyt c from the IMM and the initiation of apoptosis, are discussed

Page generated in 0.0988 seconds