• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 444
  • 9
  • 8
  • Tagged with
  • 470
  • 273
  • 124
  • 79
  • 68
  • 60
  • 56
  • 53
  • 51
  • 49
  • 45
  • 44
  • 42
  • 41
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
461

Estudo da adsorção e dessorção do corante têxtil Crimson HEXL empregando diferentes carvões ativados / Study of adsorption and desorption of Crimson HEXL textile dye using different activated carbons

Monarin, Mauricio Marcelo Sinhorim 17 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:08:00Z (GMT). No. of bitstreams: 1 Mauricio M Sinhorim Monarin.pdf: 2075451 bytes, checksum: 650d176482da90355f19fcef0fa451d4 (MD5) Previous issue date: 2012-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The dyes are present in many plants, producing toxic and carcinogenic effluents that significantly affecting the environment when disposed of untreated. The most commonly used methods for dye removing are biological treatment, coagulation / flocculation / membranes and adsorption processes. The present study aims to evaluate the adsorption of reactive dye textile Crimson HEXL, used in industrial plants (mainly laundries) using two commercial activated carbons: the origin of bovine bones (CAO) and bituminous minerals (CAM). To compare the potential application of these two types of carbons, experiments were performed characterization and adsorption in batch system and in duplicate, consisting of the following steps: i) obtaining from the point of zero charge (pHpzc) for each carbon, ii) evaluate the influence the pH of the dye solution, iii) determine the optimal particle size of the adsorbent, iv) to investigate the influence of the stirring rate in the adsorption process, data acquisition and modeling using kinetic models available in the literature, of obtaining data of equilibrium and modeling at different temperatures using literature modeling, v) desorption of the dye in the best conditions for the particular adsorption system carbon-dye (pH and type of eluent). The experiments showed the best conditions of particle size (approximately 20-30 mesh), shaking (100 rpm) and pH of 2. The kinetic data showed a contact time of 48 hours for the system to reach equilibrium. The kinetic model Pseudo-First-Order, Pseudo-Second-Order and intra-particle diffusion showed good fits of the experimental data with high coefficients of determination and high degree of significance for each parameter in the models studied (p-level < 0,05) for the experimental equilibrium data for systems Crimson HEXL CAO and Crimson HEXL CAM, except for the model of intra-particle diffusion at 100 mg/L of system Crimson HEXL CAO. The simulation using the Langmuir model using as adsorbent CAO represented satisfactorily equilibrium data experimental temperatures of 20, 30, 40 and 50 ° C, unlike the Freundlich model which had adjustment only for the temperature of 20 ° C. To the system Crimson HEXL - CAM did not obtain a proper fit for simulating the experimental data using the equilibrium model isotherm Langmuir and Freundlich. The thermodynamic parameters &#916;Hº, &#916;Gº and &#916;Sº were evaluated and demonstrated that the adsorption of the reactive dye Crimson HEXL in CAO and CAM is an endothermic and spontaneous process. The recovery of activated carbons with reactive dyes had poor results for the recovery of the adsorbent for reuse in adsorption processes. / Os corantes estão presentes em muitas unidades industriais, gerando efluentes que são carcinogênicos e tóxicos afetando significativamente o meio ambiente quando descartados sem tratamento prévio. Os métodos mais empregados para a remoção de corantes são: tratamento biológico, coagulação / floculação / membranas e processos de adsorção. O presente trabalho pretende avaliar a adsorção do corante reativo têxtil Crimson HEXL, utilizado em unidades industriais (lavanderias principalmente) utilizando-se dois carvões comerciais ativados: de origem de ossos bovinos (CAO) e mineral betuminosa (CAM). Para comparar o potencial de aplicação destes dois tipos de carvão, experimentos foram realizados de caracterização e adsorção em sistema batelada e em duplicata, consistindo nas seguintes etapas: i) obtenção do ponto de carga zero (pHpcz) para cada carvão; ii) avaliar influência do pH da solução do corante; iii) determinar o melhor tamanho de partícula do material adsorvente; iv) investigar a influência da velocidade de agitação no processo de adsorção: obtenção de dados cinéticos e modelagem utilizando modelos disponíveis na literatura; obtenção de dados de equilíbrio em diferentes temperaturas e modelagem usando modelos da literatura; v) dessorção do corante nas melhores condições de adsorção determinadas para o sistema carvão-corante (pH e tipo de eluente). Os experimentos realizados indicaram as melhores condições de granulometria (aproximadamente 20-30 mesh), agitação (100 rpm) e pH da solução de 2. Os dados cinéticos apresentaram um tempo de contato de 48 horas para o sistema alcançar o equilíbrio. O modelo cinético de Pseudo-Primeira-Ordem, Pseudo-Segunda-Ordem e Difusão Intra-partícula apresentaram bons ajustes dos dados experimentais com elevados valores dos coeficientes de determinação e elevado grau de significância para cada parâmetro nos modelos estudados (p-level<0,05) para os dados de equilíbrio experimentais para os sistemas Crimson HEXL CAO e Crimson HEXL CAM, exceto para o modelo de Difusão Intra-partícula à 100 mg/L do sistema Crimson HEXL CAO. A simulação realizada utilizando o modelo de Langmuir empregando como adsorvente o CAO representou satisfatoriamente os dados de equilíbrio experimentais para as temperaturas de 20, 30, 40 e 50 ºC, ao contrário do modelo de Freundlich que apresentou ajuste apenas para a temperatura de 20 ºC. Para o sistema Crimson HEXL CAM não se obteve um ajuste adequado para a simulação dos dados experimentais empregando o modelo de isoterma de equilíbrio de Langmuir e Freundlich Os parâmetros termodinâmicos &#916;H0, &#916;G0 e &#916;S0 foram avaliados e mostraram que a adsorção do corante reativo Crimson HEXL em CAO e CAM é um processo endotérmico e espontâneo. A recuperação de carvões ativados com corantes reativos obtiveram resultados pouco satisfatórios para recuperação do adsorvente para reutilização em processos de adsorção.
462

Remoção do corante Azul Reativo 5G utilizando o adsorvente comercial Dowex Optipore SD-2 / Removal of Reactive Blue 5G dye using commercial adsorbent Dowex Optipore SD-2.

Oliveira, Silvia Priscila Dias de 21 February 2013 (has links)
Made available in DSpace on 2017-07-10T18:08:03Z (GMT). No. of bitstreams: 1 Silvia P Dias de Oliveira.pdf: 1230611 bytes, checksum: a3c50b4c24862ccdb82c63279b67c320 (MD5) Previous issue date: 2013-02-21 / Fundação Araucária / In this work, removal of Reactive Blue 5G dye using a commercial Dowex Optipore SD-2 adsorbent was investigated regarding variations on pH (1-12), temperature (20-50oC) and shaking (90-200 rpm) values in order to establish best adsorption conditions. The point of zero charge (pcz) was determined varying solution pH from 2 to 12 and defining the pH range where the adsorbent surface is electrically neutral. Batch kinetic experiments at pH 2 consisting on a mixture of 5 mg adsorbent and 50 mL dye solution (150 mgL-1) were performed considering four temperatures (20, 30, 40 and 50°C), under 120 rpm shaking. Regarding temperature of 30°C and shaking of 120 rpm as suitable to improve the removal of Dowex Optipore SD-2 adsorbent, batch equilibrium adsorption experiments were carried out at pH values ranging from 1 to 12 and considering dye solutions with concentration varying from 5 to 300 mg L-1. From pcz results, pH values between 4 and 10 have evidenced electrically neutral behavior on adsorbent surface. Adsorption kinetic data were interpreted according to film diffusion, superficial adsorption and pores diffusion kinetic models. Six isotherm models such as Langmuir, Freundlich and Temkin were used to describe the equilibrium data, being the Langmuir isotherm fitted better to the data with a maximum adsorption capacity (qmax) of 315 mg L-1. Performing a comparison with other adsorbents, such as orange peel, macrophyte Egeria Densa, eggshell and activated charcoal reported in literature for reactive dye removal, the Dowex Optipore SD-2 adsorbent exhibits greater adsorption capacity than the other ones, being more effective for reactive dye removal, but with a slow kinetic response. / O objetivo principal deste trabalho foi estudar a remoção do corante Azul Reativo 5G utilizando o adsorvente comercial Dowex Optipore SD-2. Foram realizados testes preliminares em sistema fechado e batelada variando o pH de 1 a 12, a temperatura de 20 a 50°C e a velocidade de agitação de 90 a 200 rpm. O ponto de carga zero (pHpcz) do adsorvente foi obtido a partir do método da titulação potenciométrica. O teste cinético foi conduzido em sistema fechado e batelada, misturando 5 mg de adsorvente com 50 mL de solução de corante (150 mg L-1), com pH 2, em quatro temperaturas (20, 30, 40 e 50°C)sob agitação constante de 120 rpm. O teste de equilíbrio foi realizado para pHs entre 1 e 12 e a concentração da solução de corante variando de 5 a 300 mg L-1, neste teste a temperatura e a velocidade de agitação foram fixadas em 30°C e 120 rpm, respectivamente. A partir da análise do pHpcz observou-se que para valores de pH entre 4 e 10 a carga superficial líquida do adsorvente é nula. A cinética de adsorção foi descrita por três modelos matemáticos: difusão no filme, adsorção na superfície e difusão nos poros. Seis modelos de isoterma, dentre eles Langmuir, Freundlich e Temkin foram utilizados para descrever dos dados de equilíbrio, sendo que Langmuir foi o que melhor se ajustou aos dados experimentais de equilíbrio. O adsorvente apresentou uma capacidade máxima de adsorção (qmax) de 315 mg L-1. Comparando com outros adsorventes, tais como bagaço de laranja, Macrófita Egeria Densa, casca de ovo e carvão ativado, encontrados na literatura para a remoção de corantes reativos, o adsorvente Dowex Optipore SD-2 apresenta capacidade máxima de adsorção muito superior aos demais adsorventes, sendo mais efetivo na remoção de corante reativo, no entanto apresenta uma cinética lenta.
463

Aplicação da técnica de eletro-floculação no tratamento de efluentes de curtume / Application of electroflocculation technique for the tannery effluent treatment

Fornari, Marilda Menchon Tavares 12 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1 Marilda M T Fornari.pdf: 813038 bytes, checksum: 1672b5ca9a95a70d2125540cf442fb8a (MD5) Previous issue date: 2008-02-12 / In the present work has been studied the electro-flocculation efficiency on the reduction of organic and inorganic material concentrations such as Chemical Oxygen Demand (COD), turbidity, total solids and metal, mainly chromium, on an untreated tannery effluent using a pair of electrodes. For this purpose, a lab scale Electro-Flocculation (EF) reactor was constructed using an 8-L plastic cylindrical container, containing a valve in its lower part for sludge evacuation and a horizontal support in its upper part for fixing a pair of electrolytic cell in upright position into a 5-L available reactor volume. The electrodes plates, made of iron or aluminum, were connected to terminals of direct current power supply. All the physical-chemistry parameters were measured following the Standard Methods for water analysis, while metal concentrations were determined using the Synchrotron X-Ray Fluorescence technique, available in the Brazilian Synchrotron Light Laboratory. In order to determine optimal operating conditions, the effects of current intensity, electrodes distance, effluent initial pH, and EF time have been experimentally examined, according to a statistic planning and correlation analysis. For each electrode, a total of 11 EF experiments were carried out for maximum and minimum values of EF reactor operating parameters. Applying a 95% confidence level into the correlation analysis between EF parameters, the physical-chemistry parameters and metal concentrations were reduced in all of them when the effluent initial pH was increased, while the EF time and the applied voltage were reduced for small electrodes distances. Moreover, the EF treatment efficiencies tend towards higher values with an increasing on the current intensity. In order to determine the best reactor operating values, other EF experiments were performed varying the effluent initial pH from 6.5 to 9.0 and from 6.0 to 8.5 for iron and aluminum electrodes, respectively, fixing the distance between the electrodes in 4.0 cm, the current intensity in 5.5 A and the EF time in 30 minutes. Nevertheless, these EF experiments have shown that the reduction factor on parameter concentrations due to an increasing of effluent initial pH was not significant compared to prior experiments. Henceforth, the effluent pH value was maintained near to the original one for the next EF treatments, avoiding introducing other substances into the effluent. Keeping effluent pH value in 7.5, other EF experiments were performed changing the EF time from 15 to 120 min., fixing current intensities and electrode distances in 5.5 A and 4.0 cm, respectively. For these reactor conditions, the EF time setting up in 30 min. was enough to get a good efficiency according the reduction factor in the most of parameters examined, without increasing a lot the reactor electrical power, for both kinds of electrodes. The EF reactor purpose and examined has shown a high efficiency on turbidity and chromium concentration reduction factor (98%). Furthermore, this system can be also used to reduce other elementary concentrations such as calcium, potassium and zinc, for both kinds of electrodes (Fe/Al). In comparison with iron electrodes, aluminum one has reported a better reduction factor (80%) on COD values and a good reduction factor (50%) on iron concentration. On the other hand, the EF method for tanneries effluent treatment system was also compared with conventional method using coagulating and flocculating agents, showing a great similarity between them in the reduction factor. In the EF method is not necessary to introduce substances to start the coagulation and flocculation process in effluent treatment. / Este trabalho tem por objetivo o estudo da eficiência da eletro-floculação na redução das concentrações de substâncias orgânicas e inorgânicas expressas através dos parâmetros: Demanda Química de Oxigênio (DQO), turbidez, sólidos totais e metais, principalmente o cromo, em efluente de curtume não tratado, utilizando um par de eletrodos. Para esse propósito foi construído, em escala laboratorial, um reator confeccionado a partir de um recipiente plástico de 8 litros, contendo uma válvula na parte inferior, para a retirada dos sedimentos, e um suporte horizontal na parte superior para a fixação do par de células eletrolíticas, em posição perpendicular dentro do reator com volume útil de 5 litros. As placas de eletrodos, de ferro e alumínio, foram conectadas a uma fonte de alimentação de energia.Todos os parâmetros físico-químicos foram determinados seguindo o Método Padrão para análise de água, enquanto que as concentrações de metal foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF), disponível no Laboratório Nacional de Luz Síncroton. A fim de determinar as condições ótimas de operação, os efeitos da intensidade da corrente, distância entre eletrodos, pH inicial do efluente e tempo de eletrólise foram avaliados experimentalmente, de acordo com um planejamento estatístico e análise de correlação. Para cada eletrodo, foram realizados 11 experimentos de EF com valores máximos e mínimos para os parâmetros de operação do reator. Empregando um nível de 95% de confiança na correlação de análises dos parâmetros a análise de correlação entre os parâmetros de EF, os modelos mostraram tendência de redução nas concentrações dos parâmetros físico-químicos e de metais, quando o pH inicial do efluente foi elevado, enquanto o tempo de EF e a voltagem aplicada apresentaram tendência de redução nos valores para uma menor distância entre os eletrodos.. Além disso, a eficiência do tratamento de EF tende a valores mais elevados com o aumento na intensidade de corrente. A fim de determinar as melhores condições de operação do reator, outros experimentos EF foram feitos variando o pH inicial de 6.5 a 9.0 e de 6.0 a 8.5 para eletrodos de ferro e alumínio, respectivamente, fixando a distância entre os eletrodos em 4.0 cm, a intensidade da corrente em 5.5 A e o tempo de EF em 30 minutos. Entretanto, esses experimentos mostraram que o fator de redução percentual na concentração dos parâmetros, causada pelo aumento no pH inicial do efluente, não foi significativo comparado aos experimentos anteriores. Nos tratamentos posteriores de EF, o pH do efluente foi mantido próximo ao original, evitando a introdução de outras substâncias no efluente. Mantendo o valor do pH do efluente em 7.5, outros experimentos de EF foram realizados variando o tempo de eletrólise de 15 a 120 min., e fixando a intensidade da corrente e distância entre os eletrodos em 5.5 A e 4.0 cm., respectivamente. Nessas condições, o tempo de EF fixado em 30 min. foi suficiente para alcançar uma boa eficiência, de acordo com o fator de redução, para maioria dos parâmetros analisados, sem aumentar muito a potência elétrica do reator, para os dois tipos de eletrodos. Os experimentos realizados com reator de EF mostraram uma alta eficiência na redução da turbidez e concentração de cromo (98%). Ademais, esse sistema também pode ser utilizado na redução de outras concentrações elementares como cálcio, potássio e zinco, para ambos os tipos de eletrodos (Fe/Al). Em comparação com os eletrodos de ferro, o eletrodo de alumínio apresentou um melhor fator de redução nos valores de DQO (80%) e um bom fator de redução de ferro (50%). Por outro lado, o método de EF para o tratamento de sistema de efluentes de curtumes foi também comparado ao método convencional utilizando agentes coagulantes e floculantes, mostrando uma grande semelhança entre eles no fator de redução. No método EF não é necessário introduzir substâncias para iniciar o processo de coagulação e floculação no tratamento de efluente.
464

Avaliação do potencial de utilização da macrófita aquática seca Salvinia sp. no tratamento de efluentes de fecularia / Evaluation of the potential use of dry aquatic macrophyte Salvinia sp. in an industrial cassava wastewater treatment

Limons, Rafaela da Silva 11 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:09Z (GMT). No. of bitstreams: 1 Rafaela da Silva Limons.pdf: 1188810 bytes, checksum: 3222e9bb51995ce2bffdbb6505a56d20 (MD5) Previous issue date: 2008-02-11 / The industries of cassava processing are considered great polluting, therefore they generate highly pollutant a wastewater, the manipueira, with high concentration of organic substance. The method of treatment used in these industries is basically the system of stabilization. However, in function of the raised organic load, normally the effluent end if does not present in adequately favorable conditions for the ousting in hydrias resources, being essential a complementary treatment, so that the wastewater is adjusted to the current law. Thus, this work had for objective to study the removal of organic substance, nutrients and metals weighed, by means of a batelada system, for the dry biomass of the macrófita Salvinia sp. In this direction, with intention to investigate the factors that influence the capacity of removal of these contaminantes and to understand the mechanisms of this process, it was used as technique of factorial planning rotational central delineation composed - DCCR, verifying the influence of three independent 0 variable: pH initial, initial concentration of biomass - C and agitation -. The gotten results had shown that the best operational conditions had in accordance with varied the studied pollutant, thus best pH were: 5,8 for the match - P and zinc - Zn and 8,2 for the chemical demand of oxygen - DQO, nitrogen - N and have covered - Cu; the best concentration of biomass of 0,0013 g/mL for the DQO, the N, P and Zn and 0,0053 g/mL for the Cu and the 30 agitation of rpm for DQO and N and 120 rpm for the P, Zn and Cu. For the Compact disc removal of 100% in practically all was gotten the assays, in virtue of low the initial concentration of this metal. The gotten results had allowed to conclude respectively that in the best operational conditions the dry biomass of the Salvinia sp. influenced positively in process, reaching 97.91% of removal of DQO, 99.96% of P and 99.67% of N, with initial concentration of 20.480, 121,6 and 350 mg/L. Moreover, the results had shown to the promising character of the Salvinia sp. as biossorvente, being capable to adsorver up to 76,70% of íons of Zn, 99.79% of Cu and 100% of íons Compact disc, in industrias liquid residues contend small metal concentration heavy. The assays with the isotherms of adsorção of Zn and Cu had indicated that the capacity of biossorção of copper and 0,50 zinc had been approximately of 0,70 and meq/g in pH 5,0, being that the best adjustment occurred with the Isotherm of Sips. / As indústrias de processamento de mandioca são consideradas grandes poluidoras, pois geram um resíduo líquido altamente poluente, a manipueira, com alta concentração de matéria orgânica. O método de tratamento empregado nestas indústrias é basicamente o sistema de lagoas. Entretanto, em função da elevada carga orgânica, normalmente o efluente final não se apresenta em condições adequadamente favoráveis para o despejo em recursos hídricos, sendo essencial um tratamento complementar, para que o resíduo líquido esteja adequado à legislação vigente. Assim, este trabalho teve por objetivo estudar a remoção de matéria orgânica, nutrientes e metais pesados, por meio de um sistema batelada, pela biomassa seca da macrófita Salvinia sp. Neste sentido, com o intuito de investigar os fatores que influenciam a capacidade de remoção destes contaminantes e para se compreender os mecanismos deste processo, utilizou-se como técnica de planejamento fatorial o delineamento composto central rotacional - DCCR, verificando a influência de três variáveis independentes: pH inicial, concentração inicial de biomassa - C e agitação - A. Os resultados obtidos mostraram que as melhores condições operacionais variaram de acordo com o poluente estudado, assim o melhor pH foi: 5,8 para o fósforo - P e zinco - Zn e 8,2 para a demanda química de oxigênio - DQO, nitrogênio - N e cobre -Cu; a melhor concentração de biomassa de 0,0013 g/mL para a DQO, o N, P e Zn e 0,0053 g/mL para o Cu e a agitação de 30 rpm para a DQO e N e 120 rpm para o P, Zn e Cu. Para o Cd obteve-se remoção de 100% em praticamente todos os ensaios, em virtude da baixa concentração inicial deste metal. Os resultados obtidos permitiram concluir que nas melhores condições operacionais a biomassa seca da Salvinia sp. influenciou positivamente no processo, alcançando 97,91% de remoção de DQO, 99,96% de P e 99,67% de N, com concentração inicial de 20.480, 121,6 e 350 mg/L, respectivamente. Além disso, os resultados mostraram o caráter promissor da Salvinia sp. como biossorvente, sendo capaz de adsorver até 76,70% de íons de Zn, 99,79% de Cu e 100% de íons Cd, em resíduos líquidos industrias contendo pequena concentração de metais pesados. Os ensaios com as isotermas de adsorção de Zn e Cu indicaram que a capacidade de biossorção do cobre e zinco foram aproximadamente de 0,70 e 0,50 meq/g em pH 5,0, sendo que o melhor ajuste ocorreu com a Isoterma de Sips.
465

Estudo da redução de Cr(VI) usando espécies de macrófitas aquáticas vivas pela técnica de fluorescência de raios-X de alta resolução / Hexavalent chromium detoxification by living aquatic macrophites root-based biosorption using high resolution x-ray fluorescence

Martin, Neiva 08 October 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:10Z (GMT). No. of bitstreams: 1 Neiva Martin.pdf: 2565426 bytes, checksum: 9ed40e36b9798ff30f3a52b416d705e9 (MD5) Previous issue date: 2008-10-08 / In this work, the chromium ions bioaccumulation experiment was carried out using three species of aquatic macrophytes: Salvinia auriculata, Pistia stratiotes and Eicchornia crassipes, in order to confirm the hexavalent chromium detoxification during the biosorption process. Previously, a chromium speciation test based on chemical extraction of trivalent chromium from hexavalent chromium-doped hydroponic solutions was also performed at different pH, in order to verify if the nutritive solution pH could be responsible by the natural reduction of oxidation state on chromium before the biosorption process by the plants. No reduction from Cr(VI) to Cr(III) was observed at all solution pH. Based on the peculiar characteristics of High Resolution X-ray Fluorescence technique (HR-XRF), which allows to measure the X-ray Kß spectral line energy with good energy resolution (around 2,0 eV) for the transition metal region, the change on oxidation state of hexavalent chromium was possible to study through the Kß1,3, Kß2,5 and Kß spectral lines, which bring up information on chromium oxidation state and chemical environment. The HR-XRF measurements were performed at the XRD1 vacuum chamber available in the National Laboratory of Synchrotron Light, located near Campinas city. After collection, dry roots and chromium compound standard were prepared in compact disk by pressing. Each sample disk, spherical curved analyzer, and radiation detector were placed in a circle of Rowland within an arrangement of Johann. Another radiation detector was also used to monitoring of monochromatic X-ray beam intensity during the measurements. All the samples were irradiated by a 6.1 keV monochromatic X-ray beam. All the emission spectra were normalized to the monitor counts, and subtracted the organic matrix contribution and chromium absorption edge. Based on the spectral Kß2,5 peak intensity of roots and standard samples, the total chromium uptake concentration in plant was calculated, indicating that there is approximately 1.0 % of chromium per dry biomass after 27 days of experiment. When both Cr-Kß spectra of macrophytes roots with Cr(III) and Cr(VI) treatment were compared, their spectral Kß2,5 peak were identical in energy and width for the three aquatic plants, suggesting that the chromium reduction from hexavalent to trivalent form have occurred in all cases studied. The peak width at half maximum for Kß2,5 in all root samples were slightly larger than the chromium compound samples, which can be explained by the fact that there is the possibility to have different ligands to chromium ions inside the biological structure of roots. Based on these results, the chromium detoxification from hexavalent to trivalent form have actually happened during the biosorption of chromium into the macrophytes roots. Finally, these aquatic macrophytes have a great potential to detoxificate and accumulate of chromium ions that can be very useful to the metal removal from industrial effluents. / Neste trabalho foi feito o experimento de bioacumulação do cromo trivalente e hexavalente por três espécies de macrófitas aquáticas: Salvinia auriculata, Pistia stratiotes e Eicchornia crassipes, visando verificar a ocorrência do processo de redução do Cr(VI) durante a biossorção. Previamente, um teste de especiação de cromo baseado em extração química do cromo trivalente a partir de uma solução hidropônica dopada com cromo hexavalente, foi realizado em diferentes pHs, para verificar se o pH da solução nutritiva pode ser o responsável pela redução natural do estado de oxidação do cromo antes do processo de biossorção pelas plantas. Não foi observada a redução do Cr(VI) para Cr(III) no pH da solução de cultivo. Pelas características da técnica de Fluorescência de Raios-X de Alta Resolução em Energia (HR-XRF), que permite medir a energia das linhas espectrais de raios X Kß com alta resolução em energia (em torno de 2,0 eV) para a região dos metais de transição, foi possível estudar a mudança do estado de oxidação do cromo hexavalente através das linhas espectrais Kß1,3, Kß2,5 e Kß , que traz informação sobre o estado de oxidação do metal e seu ambiente químico. As medidas de HR-XRF foram realizadas na câmara de vácuo XRD1, no Laboratório Nacional de Luz Síncrotron, em Campinas. Após a coleta, discos compactados de raízes secas e padrões de compostos de cromo foram preparados. Cada disco de amostra, o analisador esférico, e o detector de radiação foram acomodados em um círculo de Rowland com arranjo de Johann. Durante as medidas, um detector foi usado para monitorar a intensidade do feixe de raios X monocromáticos incidentes. Todas as amostras foram irradiadas com feixe monocromático de 6,1 keV. Os espectros de emissão foram normalizados pelas contagens do monitor, e subtraída as contribuições da matriz orgânica e da borda de absorção do cromo. Baseado na intensidade da linha espectral K&#946;2,5 das amostras de raízes e padrões, a concentração de cromo total nas plantas foi calculada, indicando que esta é de aproximadamente 1,0% por biomassa seca após 27 dias de experimento. Os espectros de emissão Cr-Kß das raízes das macrófitas tratadas com Cr(III) ou Cr(VI) foram comparados, e as suas linhas espectrais K&#946;2,5 mostraram-se idênticas em energia e largura para as três plantas aquáticas, sugerindo que a redução do cromo, de hexavalente para trivalente, ocorreu em todos os casos estudados. A largura do pico para a linha espectral Kß2,5 em todas as amostras de raízes mostrou-se maior que nas amostras de compostos de cromo, o que pode ser explicado pelo fato de que é possível haver diferentes ligantes para o íon cromo na estrutura orgânica das raízes. Baseado nesses resultados, a redução do Cr(VI) para Cr(III) ocorreu durante o processo de biossorção do cromo pelas raízes das macrófitas aquáticas. Desta forma, verifica-se que estas macrófitas têm um grande potencial para detoxificar e acumular íons cromo, podendo ser utilizada com eficiência na remoção de metais em efluentes industriais.
466

Aplicação dos processos foto-Fenton e eletrofloculação no tratamento de efluente de curtume / Application of the photo-Fenton and electrocoagulation processes at the tannery effluent treatment

Borba, Fernando Henrique 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:12Z (GMT). No. of bitstreams: 1 Fernando Henrique Borba.pdf: 3301834 bytes, checksum: 0c5216d667957cc99d5acd2dd5d59c05 (MD5) Previous issue date: 2010-02-18 / Pollution is a currently environmental problem of world concern. There are many events such as the discharging of untreated effluents in watercourses that cause the eutrophization of water bodies and bad water quality, as well as an inefficiency or lack of a current environmental law. The main goal of this dissertation was the application of solar and artificial-based photo-Fenton processes and aluminum electrodes-based electrocoagulation method in non coupled mode and in an integrated mode for the tannery effluent treatment. These effluent treatments were carried out in lab-scale reactors. In order to evaluate the performance of the reactor experimental conditions of photo-Fenton reactor, a 33 complete experimental design was performed. The lab scale EC reactor was operated at the 4 A electrical current, 4 cm electrode distance and 3 initial pH optimized values, according to the previous results obtained in another work, while the electrolysis time was varied from 5 to 120 min. For EC and photo-Fenton reactors, their performance was evaluated on the removal values of chemical oxygem demand (COD), color, turbidity, total solids (TS), total fixed solids (TFS), total volatile solids (TVS) and metal concentration. Measurements of physico-chemical parameters for untreated and treated effluent samples were performed applying the Standard Method for water analysis, while metal concentrations were determined by the Synchrotron radiation total Reflexion X-ray Fluorescence technique at Brazilian Light Synchrotron Laboratory. By an optimized photon-Fenton process at 0.5 g Fe2+ L-1, 30 g H2O2 L-1, 3 initial pH, and 120 min reaction time, tannery effluent was treated achieving a high performance in pollutant removal as reported by 98.1, 96.4, 98.8, 71.8, 32.1 and 98.5 percent removal for COD, color, turbidity, TS, TFS, and TVS, respectively. As a primer treatment stage, electrocoagulation technique was not achieved a well successful result based on the physico-chemical parameter values reduction as compared with photo-Fenton process. However, an integrated solar irradiation-based photo-Fenton and Al electrodes-based electrocoagulation with 15 min electrolysis time has achieved recommended values by the Brazilian environmental law for Cr concentration (0.24 mg Cr L-1) and DQO (107 mg O2 L-1). Considering both the costs of electrical energy and material and the generated sludge discharging, one m3 of tannery effluent should cost R$ 56.30 for a treatment system based on an integrated and optimized photo Fenton and electrocoagulation processes. Finally, the integrated solar-based photo Fenton and electrocoagulation method is suggested as an efficient one, instead to apply a unique process. / A poluição ambiental é um dos grandes problemas nos países desenvolvidos e em desenvolvimento. Isto é decorrente de uma série de fatores, como o despejo de efluentes não tratados em corpos hídricos e a ineficiência e/ou a falta de legislação ambiental vigente. O objetivo principal deste trabalho é aplicar os processos foto-Fenton com irradiação solar e/ou artificial, a técnica da eletrofloculação e a integração destes processos no tratamento de efluente de curtume. Ambos os processos de tratamento do foto-Fenton e da eletrofloculação foram conduzidos em reatores a escala laboratorial. Para a técnica da eletrofloculação foi utilizado um par de placas de alumínio como eletrodos no reator de eletrofloculação. Para avaliar as melhores condições de processo do sistema foto-Fenton, foi aplicado um planejamento experimental 33 completo. Para a técnica da eletrofloculação manteve-se constante a intensidade de corrente, pH inicial do efluente bruto e distância entre os eletrodos, variando-se o tempo de eletrólise de 5 à 120 min. A eficiência de ambos os processos foram avaliadas com base na redução de Demanda química de oxigênio (DQO), cor, turbidez, sólidos totais (ST), sólidos totais fixos (STF), sólidos totais voláteis (STV). Para a técnica da eletrofloculação e dos processos integrados também foram avaliados a redução da concentração dos metais pesados. Todas as medidas dos parâmetros físico-químicos foram realizadas aplicando os métodos padrões do Standard Methods for the Examination of Water and Wastewater para amostra não tratada e tratada. As concentrações dos metais pesados foram determinadas usando a técnica de fluorescência de raio X por reflexão total, na linha de Luz (D09-XRF) do Laboratório Nacional de Luz Synchrotron. A maior eficiência na redução dos poluentes verificada no processo foto-Fenton foi de 98,1, 96,4, 98,8, 71,8, 32,1 e 98,5 para valores da DQO, cor, turbidez, ST, STF e STV, respectivamente, nas condições operacionais do reator: concentração de ferro de 0,5 gL-1, concentração de peróxido de hidrogênio de 30 gL-1, pH inicial 3 e tempo reacional de 120 min. No entanto a técnica da eletrofloculação não apresentou boa redução nos valores dos parâmetros físico-químicos. Após a aplicação dos processos integrados do foto-Fenton com irradiação solar e da eletrofloculação em tempo de eletrólise de 15 min, foi alcançado valores mínimos de Cr e DQO no efluente tratado, contendo 0,24 mg Cr L-1 e 107 mg O2 L-1 da DQO. O custo do tratamento do efluente e da disposição final do lodo gerado no processo integrado FFs&#8594;EF foi de R$ 56,30 m3 do efluente de curtume tratado. Este processo integrado reduziu as concentrações de cromo, ferro e DQO, a níveis permitidos pelas legislações ambientais. Baseada na redução da matéria orgânica e inorgânica, o método integrado FFs&#8594;EF pode ser recomendado como uma substituição eficiente ao método individual.
467

Utilização da eletrocoagulação no tratamento de efluente da indústria galvânica / Use of electrocoagulation in the treatment of wastewater from galvanizing industry

Theodoro, Paulo Sérgio 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1 Paulo Sergio Theodoro.pdf: 1744465 bytes, checksum: 132da5a46d9247da552f8a27ee087fed (MD5) Previous issue date: 2010-02-18 / The aim of this work is devoted to reduction of the environmental impact of galvanic industry effluents. An electro-coagulation (EC) laboratory scale system using iron plates electrodes was studied for the removal of organic and inorganic pollutants as a by-product from the treatment of galvanic process based-platining industry. An EC reactor consisting of a 1,5 L conical container and a set of seven firmly assembled iron electrode plates, which were parallelly arranged to each other and electrically operated in mono-polar mode, was built. A 1.0 cm gap between the anode and cathode plates using a non-conducting horizontal support was chosen in order to operate the EC reactor in a low electrical current range. A long, electrical rotating cilindrical rotor, with 2,7cm blades at the end of it, made in non-conducting material, was used to turn mechanically the effluent around the rotor axis during the EC treatment. In addition, a 225 cm2 active electrode surface area was kept during the whole EC experiments. In order to obtain optimal values of reaction time, electrical current, rotor angular velocity, and initial effluent pH, a central composite rotatable design (CCRD) was applied. A wide range of reaction time (10-60 min), electrical current (0.3-3.0 A), rotor angular velocity (50-300 rpm), and initial efluent pH (3-10) were used, performing a total of 28 runs with 24+2x4 axial points and 4 central points. Physico-chemical parameters such as chemical oxygen demand (COD), color, turbidity, total solids, and metals (Cr, Ni, Zn, and Cu) were used as response variables. The measurements of physico-chemical parameter and metal concentration values in non- and treated waste waters were carried out by applying the Standard Methodology and the Synchrotron Radiation X-Ray Fluorescence (SR-TXRF) technique, respectively. Using the Statistica software, a 95%-significance level (p<0.05) of the predicted models and interaction effects between reactor operating variables on response variables were evaluated using 3-D response surface curves and analysis of variance. With the factorial design was obtained the following optimum conditions of the reactor, 35 minutes for the time of electrolysis, 170 rpm for agitation, 2.2 A for the electric current and 6.5 for pH. Under these conditions the removal of color and turbidity reached 100%, another considerable value was the removal of around 90% of COD and total solids. Moreover, a removal of around 99% of Zn and Cu was obtained, whereas for Cr and Ni obtained a removal of 100%. Finally, the results of technical and economic analysis showed the cost obtained by the treatment, indicating clearly that the method of electro-coagulation is very promising for industrial application. / O presente trabalho tem como objetivo remover os poluentes de um efluente de galvanização, de modo a reduzir o impacto ambiental dos efluentes da indústria galvânica. Para a remoção dos poluentes, orgânicos e inorgânicos, gerado nos processos de galvanização foi aplicada a eletrocoagulação (EC) em escala de laboratório utilizando eletrodos de ferro. Foi construído um reator de EC, constituído por um recipiente cônico com capacidade de 1,5 L e um eletrodo de ferro montado firmemente com seis placas de ferro, que foram dispostas paralelamente com uma distância de 1(um) centímetro, operado em modo mono-polar. O sistema de agitação mecânico foi construído com duas pás de geometria cilíndrica de 2,7 cm e uma haste de 31,5 cm feito com material não condutor acoplado em um motor elétrico. Durante o experimento da EC foi utilizada uma área efetiva de 225 cm2 do eletrodo. A fim de obter valores ideais do tempo de eletrolise, corrente elétrica, agitação e pH inicial do efluente, foi aplicado o planejamento estatístico composto central (DCCR) com fatorial 24+2X4 pontos axiais + 4 ponto centrais, totalizando 28 ensaios experimentais. Os valores aplicados as variáveis independentes foram de 0,3 a 3 A para a corrente, de 10 a 60 min. para o tempo de eletrolise, de 3 a 10 para o pH inicial e agitação como valores entre 50 e 300 rpm. Foram utilizadas como variáveis resposta os parâmetros físico químico tais como, a demanda química de oxigênio (DQO), cor, turbidez, Sólidos totais e concentração dos metais Cr, Ni, Zn e Cu.Todos os parâmetros físico-químicos foram determinados através o Método Padrão para análise de água, enquanto que as concentrações dos metais foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF). Utilizando o software Statistica, com nível de significância de 95% (p <0,05), os modelos preditos e os efeitos de interação entre as variáveis de operação do reator e as variáveis respostas foram avaliados, utilizando as curvas 3-D de superfície de resposta e a análise de variância. Com o planejamento fatorial foi obtido as seguintes condições ótimas de trabalho do reator, 35 minutos para o tempo de eletrolise, 170 rpm para a agitação, 2,2 A para a corrente elétrica e 6,5 para o pH. Nestas condições a remoção da cor e turbidez alcançaram 100%, outro valor considerável foi a remoção em torno de 90% da DQO e sólidos totais. Além disso, uma remoção em torno de 99% de Zn e Cu também foi obtida, enquanto que para o Cr e Ni obteve-se uma remoção de 100%. Finalmente, os resultados da análise técnico-econômica mostraram o baixo custo obtido pelo tratamento, evidenciando claramente que o método da eletrocoagulação é muito promissor para aplicação industrial.
468

Avaliação da remoção do corante comercial reativo Azul 5G utilizando macrófita Salvínia sp. / Evaluation of the removal of commercial reactive blue 5G dye using macrophyte Salvínia sp.

Cervelin, Patricia Caroline 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:15Z (GMT). No. of bitstreams: 1 Patricia C Cervelin.pdf: 689466 bytes, checksum: b74333db0911dc152167518d0ffcac74 (MD5) Previous issue date: 2010-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Among the main contributors to the contamination of water by industrial waste is the textile industry. The textile sector is a major producer of chemicals, such as colors, and generator large volumes of effluent. The textile dye is a product of high toxicity, and most of them are considered carcinogenic. Thus the removal of dyes in industrial effluents is of great interest, since such contaminants can affect water clarity, the solubility of gases in receiving bodies and change the processes of photosynthesis. In addition there are technologies for the removal of dye of effluent, such as activated charcoal, few studies have examined the ability of dye removal by biological origin, which would decrease the cost of treating this waste. Thus the process of biosorption used in this study was to investigate the application of macrophyte Salvinia sp. in nature and pre-treated in a basic with NaOH, and an acid with H3PO4, as low cost biosorbent for the removal of dye Blue 5G. The effect of pH and temperature was investigated in the biosorption process and proved to be variables that affect the ability to remove the dye solution. The adsorption data were adjusted to balance using the kinetic models of pseudo-first order and pseudo-second order. The models of adsorption isotherms of Langmuir, Freundlich and Sips were used to describe the experimental data of equilibrium of biosorption process. The thermodynamic parameters of biosorption process were obtained. The results showed that the balance of the system was reached in approximately 48 hours of contact, with removal of dye Blue 5G of 98.35% for the Salvinia sp. in nature, at pH 1 and temperature of 60°C and 97.06% for the Salvinia sp. pre-treated with NaOH, 96.42% for the Salvinia sp. pre-treated with H3PO4 at a temperature of 45°C. The model of pseudo-second order showed satisfactory fit with experimental data. Among the models studied, the Langmuir isotherm described excellently the experimental data for the three biomasses studied, with maximum adsorption capacity of 24.26 mg/g at 30°C for biomass pre-treated in basic mean. The study of thermodynamic parameters of biosorption of dye Blue 5G showed that biosorption is endothermic nature and has a great affinity between the biomass and dye. This study found that the biomass of macrophyte Salvinia sp. pré-treated with NaOH has potential application in the removal of reactive dye Blue 5G, as alternative adsorbent and low cost. / Entre os principais contribuintes para a contaminação de águas por resíduos industriais pode-se citar a indústria têxtil. O setor têxtil é conhecido pela elevada utilização de produtos químicos, como os corantes, e gerador de grandes volumes de efluente. O corante têxtil é um produto de alta toxicidade, sendo que em sua maioria são considerados carcinogênicos. Desta forma a remoção de corantes em efluentes industriais é de grande interesse, uma vez que esse contaminante pode afetar a transparência da água, a solubilidade dos gases nos corpos receptores e alterar os processos de fotossíntese. Mesmo com variadas tecnologias para remoção de corante do efluente, como carvão ativado, são raros os estudos que tem analisado a capacidade de remoção de corantes por origem biológica, o que diminuiria os custos de tratamento desse resíduo. Desta forma o processo de biossorção empregado neste trabalho teve por objetivo investigar a aplicação da macrófita Salvínia sp. in natura, e pré-tratada em meio básico com NaOH, e em meio ácido com H3PO4, como biossorvente de baixo custo para a remoção do corante comercial reativo Azul 5G. O efeito do pH e da temperatura foi investigado no processo de biossorção e mostraram ser variáveis que afetam a capacidade de remoção do corante da solução. Os dados de adsorção de equilíbrio foram ajustados empregando os modelos cinéticos de pseudo-primeira ordem e pseudo-segunda ordem. Os modelos de isotermas de adsorção de Langmuir, Freundlich e Sips foram utilizados para descrever os dados experimentais de equilíbrio do processo de biossorção. Os parâmetros termodinâmicos do processo de biossorção foram obtidos. Os resultados demonstraram que o equilíbrio do sistema foi atingido em aproximadamente 48 horas de contato, com remoção de corante Azul 5G de 98,35% para a Salvínia sp. in natura e 97,06% para a Salvinia sp. pré-tratada com NaOH, em pH 1 e temperatura de 60°C, e remoção de 96,42% para a Salvínia sp. pré-tratada com H3PO4 em temperatura de 45°C. O modelo de pseudo-segunda ordem apresentou ajuste satisfatório com os dados experimentais. Entre os modelos estudados, a isoterma de Langmuir e Sips descreveram satisfatoriamente os dados experimentais para as três biomassas estudadas, apresentando capacidade máxima de adsorção de 24,26 mg/g e 24,83 mg/g, para Langmuir e Sips, respectivamente, à temperatura de 30°C para a biomassa pré-tratada em meio básico. O estudo dos parâmetros termodinâmicos de biossorção do corante Azul 5G demonstrou que a biossorção é de natureza endotérmica e demonstra grande afinidade entre a biomassa e o corante. Este estudo verificou que a biomassa da macrófita Salvínia sp. pré-tratada com NaOH apresenta potencial de aplicação na remoção do corante reativo Azul 5G, como adsorvente alternativo e de baixo custo.
469

Tratamento de efluente têxtil utilizando o processo foto-fenton / Treatment of textile effluent using photo-fenton process

Manenti, Diego Ricieri 25 February 2011 (has links)
Made available in DSpace on 2017-07-10T18:08:15Z (GMT). No. of bitstreams: 1 Diego Ricieri Manenti.pdf: 2926963 bytes, checksum: 74aa89bdde44c5ef6942846129864678 (MD5) Previous issue date: 2011-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this work was to study the performance of the photo-Fenton process using both the artificial UV and solar sources on the textile effluent treatments. Preliminary photo-Fenton experiments for mineralization and degradation of organic and inorganic pollutants as well as of synthetic dyes were carried out in order to assess the best experimental conditions by photo-Fenton process. As synthetic textile effluent a mixture of six dyes: Solophenyl orange TGL (C25H33ClN6O6S2), Solophenyl blue 71 (C40H23N7Na4O13S4), Solophenyl scarlet BNLE (C44H32N10Na4O16S4), Solophenyl yellow ARL (C48H26N8Na6O18S6), Solophenyl black FR (C44H32N13Na3O11S3) e Navy Blue 98 (C38H24N5Na3O13S3) that contained 50 mg L-1 concentration was prepared and diluted in distillated water. The photo-Fenton experiments by using a set of high-pressure mercury lamps and solar light as artificial and natural UV irradiation sources were performed in laboratory scale. As reactor operational parameters to be optimized by a 33 full factorial experimental design: hydrogen peroxide and divalent iron ion as well as the initial solution pH were chosen as variables, keeping constant a reaction time of 120 min that was enough to warrant the maximum (chemical oxygen demand) COD and color removal. The efficiency of photo-Fenton process applied in the treatment of synthetic and real effluents, was evaluated based on the parameters: values of COD, color, turbidity, total organic carbon (TOC), absorbance at a wavelength of maximum absorption for the dyes and simple aromatic compounds and conjugated reductions, as well as behavior analysis of the evolution the sulfate, nitrate inorganic, organic nitrogen and ammonia concentrations. Second-degree models for the COD and color removal percents were proposed to model the photo-Fenton experiments data in order to reduce the cost of running such a photo-Fenton experiment as well as to obtain optimum values of the reactor operating parameters. Second-degree models were also validated by ANOVA. Predicted yields showed good validation with experimental yields. The values of the optimized reactor operational parameters were 3.0, 6.0 g L-1, and 0.05 g L-1 for initial pH, hydrogen peroxide and divalent iron concentrations, respectively, for both photo-Fenton processes. Based on this optimized experimental conditions, almost 100% removals of physico-chemical parameter such as COD, color, turbidity and COT for real textile effluents. The aromatics compounds were showed more resistant to reaction, persisting for longer. It can be noticed that the degradtion of the organic and inorganic matters were verified by the nitrification process and, the sulfates formation and reduction. The process presented similar efficiencies with both solar and artificial irradiation, thus suggesting the use of solar photo-Fenton, as it proved to be an efficient alternative besides using a source of clean and renewable energy. / O objetivo deste trabalho é avaliar o desempenho do processo foto-Fenton, utilizando energia solar e artificial como fontes de irradiação UV, no tratamento de efluentes têxteis. Foram realizados experimentos preliminares para avaliar a eficiência do processo foto-Fenton na mineralização e degradação dos poluentes orgânicos e inorgânicos, bem como dos corantes sintéticos. Para tanto, foi preparado o efluente têxtil sintético pela mistura de seis corantes: Laranja TGL (C25H33ClN6O6S2), Azul FGLE (C40H23N7Na4O13S4), Escarlate BNLE (C44H32N10Na4O16S4), Amarelo ARLE (C48H26N8Na6O18S6), Preto FR (C44H32N13Na3O11S3) e Marinho BLE (C38H24N5Na3O13S3), em água destilada, com concentração de 50 mg L-1. Os experimentos foram realizados em reatores de escala laboratorial utilizando fontes de irradiação UV natural e artificial. Os parâmetros operacionais dos reatores: pH inicial e a concentração dos reagentes H2O2 e Fe2+, foram otimizados baseados nos valores da demanda química de oxigênio (DQO) e descoloração, a partir de um planejamento fatorial 33 completo com o tempo de irradiação constante em 120 minutos. A eficiência do processo foto-Fenton, aplicado no tratamento dos efluentes sintético e real, foi avaliada baseada nos parâmetros: redução dos valores da DQO, cor, turbidez, carbono orgânico total (COT), absorvância nos comprimentos de onda de máxima absorção relativos aos corantes e aos compostos aromáticos simples e conjugados, além da análise do comportamento da evolução das concentrações de sulfato, nitrato inorgânico, nitrogênio orgânico e amoniacal. Para auxiliar na obtenção das condições ótimas dos parâmetros operacionais do reator e redução dos custos do processo foto-Fenton, as respostas experimentais para a redução da DQO e da cor foram ajustados por um modelo previsto de segunda ordem, o qual apresentou uma boa modelagem dos dados, validado pela ANOVA. Os valores ótimos operacionais do reator, para ambos os processos foto-Fenton no tratamento do efluente real, foram: pH = 3,0, concentração de H2O2 = 6,0 g L-1 e concentração de Fe2+ = 0,05 g L-1. Nestas condições, foram obtidos valores próximos a 100% de redução dos parâmetros físico-químicos DQO, cor, turbidez e COT. Os compostos aromáticos se mostraram mais resistentes a reação, persistindo por mais tempo. A degradação da matéria orgânica e inorgânica foi verificada analisando a evolução do processo de nitrificação e a formação ou redução de sulfatos. Os processos apresentaram eficiências similares tanto com irradiação solar como artificial, desta forma, sugere-se a utilização do processo foto-Fenton solar, pois mostrou ser uma alternativa eficiente além de utilizar uma fonte de energia limpa e renovável.
470

Estudo prospectivo de eventos tromboembólicos após reoperações de alta complexidade em estimulação cardíaca artificial definitiva / Prospective study of thromboembolic events after high complexity reoperation in permanent artificial cardiac pacing

Caio Marcos de Moraes Albertini 07 December 2017 (has links)
INTRODUÇÃO: Estenose e obstruções venosas são achados frequentes após o implante de cabos-eletrodos transvenosos. Manifestações clínicas dessas lesões venosas, entretanto, são raramente reportadas. Embora exista consenso de que fenômenos tromboembólicos sejam mais comuns após reoperações que envolvam o implante de novos cabos-eletrodos ou procedimentos de extração transvenosa, ainda não existem evidências que comprovem essa observação. OBJETIVOS: Em pacientes submetidos a reoperações para corrigir disfunção em cabos-eletrodos ou para mudar o modo de estimulação, o estudo visou identificar: a) a incidência de tromboembolia pulmonar (TEP) e de trombose venosa profunda (TVP) do membro superior ipsilateral ao procedimento; b) a prevalência de lesões venosas prévias ao procedimento cirúrgico, pelo estudo venográfico, e a ocorrência de modificações desse padrão seis meses após o procedimento; e c) fatores prognósticos para a ocorrência dos eventos clínicos e das alterações venográficas. MÉTODOS: No período de abril de 2013 a julho de 2016 foram estudados 84 pacientes. A avaliação pré-operatória incluiu: ultrassonografia com doppler dos membros superiores, angiotomografia de tórax com protocolo para TEP, venografia por subtração digital e coleta de biomarcadores laboratoriais específicos do sistema de coagulação e hemostasia. Os exames diagnósticos foram repetidos no momento pós-operatório para detectar os desfechos do estudo. Todos os pacientes foram acompanhados por 12 meses. Os desfechos primários foram a ocorrência de TEP ou TVP em até 30 dias após o procedimento. Os desfechos secundários foram as alterações venográficas no sexto mês após a intervenção cirúrgica. Na análise da associação das variáveis demográficas, clínicas, operatórias e laboratoriais com os desfechos do estudo, empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student. Modelos de regressão logística multivariados foram utilizados para identificar fatores prognósticos. RESULTADOS: Entre os 84 pacientes incluídos, houve equilíbrio entre os sexos e a idade média de 59,3 ± 15,2 anos. O principal motivo para realizar o procedimento cirúrgico foi a disfunção de cabos-eletrodos (75%). A remoção de cabos-eletrodos foi efetuada em 52,4% dos casos. A taxa de eventos clínicos e subclínicos pós-operatórios foi de 35,7%, representada por TVP em 24 (28,6%) casos e TEP em seis (7,1%). Alterações no padrão venográfico seis meses após a operação foram identificadas em 34,5% dos pacientes. Os fatores prognósticos independentes para TVP foram: a presença de circulação colateral significativa na venografia pré-operatória ([odds ratio (OR) = 4,7]), (intervalo de confiança de 95% (IC 95%); 1,1 - 19,8; P = 0,037), a extração transvenosa de cabos-eletrodos (OR = 27,4; IC 95%; 5,8 - 128,8; P < 0,0001) e o aumento do fibrinogênio no pós-operatório (OR = 1,02; IC 95%; 1,01 - 1,03; P = 0,018). O histórico de tabagismo foi o único fator prognóstico relacionado com a ocorrência de TEP (OR = 14,6; IC 95%; 2,3 - 91,8; P = 0,004). Somente a extração transvenosa de cabos-eletrodos foi fator prognóstico independente (OR = 5,0; IC 95%; 1,6 - 15,4; P = 0,004) para alterações venográficas pós-operatórias. CONCLUSÃO: Reoperações envolvendo o manuseio de território venoso com cabos-eletrodos previamente implantados apresentam elevados índices de complicações tromboembólicas e de alterações venográficas. Extração transvenosa de cabos-eletrodos apresentou impacto significativo no desenvolvimento de TVP e de alterações venográficas. Esses resultados mostram a necessidade de novos estudos específicos para avaliar o papel de estratégias preventivas para esse subgrupo de pacientes / INTRODUCTION: Venous stenosis or occlusion is a frequent finding in patients with previously-implanted transvenous leads. Clinical manifestations of these venous lesions, however, are rarely reported. Although there is a consensus that thromboembolic events are more frequent after reoperation involving the implantation of new leads or lead removal, there is still no evidence to support this observation. OBJECTIVES: In patients submitted to reoperations due to lead dysfunction or device upgrade, the study aimed to determine: a) the incidence of pulmonary embolism (PE) and upper extremity deep venous thrombosis (UEDVT) ipsilateral to the cardiac device; b) the prevalence of venous lesions determined by preoperative venography, and the occurrence of modifications or progression of these lesions six months after the procedure; and c) prognostic factors for clinical and venographic outcomes. METHODS: From April/2013 to July/2016, 84 patients were studied. The preoperative evaluation included: upper extremity venous ultrasound, computed tomography pulmonary angiography, digital subtraction venography and specific laboratory tests for coagulation and hemostasis. Diagnostic exams were repeated postoperatively to detect the study outcomes. All patients were followed for 12 months. Primary outcomes were occurrence of PE or UEDVT within 30 days after the procedure. Secondary outcomes were venographic changes six months after the surgical intervention. Student\'s t test, Chi-square or Fisher\'s Exact test were used in the univariate analysis of demographic, clinical, operative and laboratory variables. Multivariate logistic regression models were used to identify prognostic factors. RESULTS: Among the 84 patients included, there was a balance between gender and the mean age was 59.3 ± 15.2 years. Lead malfunctioning (75%) was the main surgical procedure indication. Lead removal was performed in 52.4% of the cases. The rate of postoperative clinical and subclinical events was 35.7%, represented by UEDVT in 24 (28.6%) cases and PE in 6 (7.1%). Alterations in the venography findings six months after the surgery were identified in 34.5% of the patients. Independent prognostic factors for UEDVT were: the presence of significant collateral circulation in the preoperative venography ([odds ratio (OR)= 4.7; [95% confidence interval (CI): 1.1 - 19.8; P=0.037), transvenous lead extraction (OR= 27.4; 95% CI 5.8-128.8; P < 0.0001) and fibrinogen variation (OR= 1.02; 95% CI 1.01 - 1.03; P=0.018). Smoking history was the only prognostic factor related to the occurrence of PE (OR= 14.6; 95% CI 2.3 - 91.8; P=0,004). Transvenous lead extraction was the only independent prognostic factor (OR= 5.0; 95% CI 1.6 - 15.4; P=0.004) for postoperative venographic endpoints. CONCLUSION: Reoperations involving previously transvenous implanted leads present high rates of thromboembolic complications and venographic alterations. Transvenous lead extraction had a significant impact on the development of UEDVT and venographic alterations. These results show the need for further studies to evaluate the role of preventive strategies for this subgroup of patients

Page generated in 0.064 seconds