• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 297
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 311
  • 158
  • 66
  • 41
  • 33
  • 28
  • 28
  • 25
  • 23
  • 23
  • 23
  • 21
  • 20
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Estudo da eficiência energética de um condicionador de ar por compressão de vapor integrado a um sistema de resfriamento evaporativo direto por aspersão

Gilberto Elias da Silva 17 March 2012 (has links)
Este trabalho apresenta o resultado do estudo realizado sobre o ganho energético do emprego integrado do sistema de resfriamento evaporativo direto por aspersão com o sistema de compressão de vapor, em uma unidade condensadora de condensação a ar, com trocador de calor do tipo aletado. O sistema de compressão de vapor atualmente é o mais utilizado para condicionamento do ar em aplicações de conforto e processos, suas unidades condensadoras podem ser tanto de condensação a ar quanto de condensação a água. Estes sistemas apesar de sua consagrada aplicação são grandes vilões de consumo de energia. Uma alternativa econômica para minimizar este impacto é o emprego do resfriamento evaporativo como pré-resfriador do ar no sistema convencional. Este fluxo de ar resfriado é utilizado na entrada da unidade condensadora do ciclo de compressão de vapor com o objetivo de reduzir o trabalho realizado pelo compressor, através da redução da temperatura de condensação do ciclo frigorífico aumentando o Coeficiente de Performance Operacional (COP). No entanto sua aplicação efetiva em unidades condensadoras a ar com trocador do tipo aletado ainda geram muitas dúvidas, quanto sua efetividade e implicações. Tendo em vista este problema foi promovida a integração destes sistemas, analisado sua efetividade. Foram utilizados bicos (aspersores, pulverizadores ou micropulverizadores) que borrifam a água na forma de gotículas ou névoas, acionados por bomba de média pressão. Por meio dos resultados obtidos, pode-se concluir que há uma melhora significativa de desempenho e eficiência do sistema de refrigeração, que utilize um sistema evaporativo direto por aspersão de forma conjugada. / This paper presents the results of the study on the energy gain of the integrated employment of the system of direct evaporative cooling spray system with vapor compression in a condensing unit condensing the air heat exchanger of the finned type. The vapor compression system is currently the most widely used for air conditioning applications and processes of comfort, its condenser units can be either air condensation and condensation water. These systems in spite of its application are allocated villains large power consumption. An economical alternative to minimize this impact is the use of evaporative cooling as a pre-cooler air in the conventional system. This flow of cooling air is utilized at the entrance of the condensing unit of the vapor compression cycle in order to reduce the work of the compressor by reducing the temperature of condensation of the refrigeration cycle by increasing the coefficient operational performance (COP). However their effective implementation in the air condensing units with finned heat exchanger of the type still generate many questions, and their effectiveness and implications. In view of this problem has been promoted the integration of these systems, analyzed its effectiveness. Were used nozzles (nozzles, spray nozzles or microwave) to spray water in the form of droplets or mist, actuated by pressure medium pump. Through the results obtained, it can be concluded that there is a significant improvement in performance and efficiency of the refrigeration system which uses a system of direct evaporative spray conjugated.
182

Resfriamento evaporativo e condicionamento de ar convencional: estudo experimental comparativo / Evaporative cooling and conventional air conditioning: a comparative experimental study

Érico Masiero 08 November 2006 (has links)
Este trabalho visa comparar experimentalmente a técnica de resfriamento evaporativo e o condicionamento de ar convencional em relação ao índice de umidificação, à redução da temperatura interna do ar e ao consumo energético. O experimento foi realizado em três células de teste submetidas às mesmas condições climáticas, semelhantes em relação às suas características construtivas e ao volume de ar interno. Cada equipamento foi instalado em uma célula, sendo que a célula restante não contou com qualquer sistema de resfriamento, cumprindo, assim, o papel de padrão de referência do comportamento higrotérmico. A técnica de resfriamento evaporativo consiste em um dispositivo eletromecânico de ventilação forçada que insufla o ar para dentro do ambiente, fazendo-o passar por um filtro de celulose umedecido com água corrente. A ventilação forçada espalha gotículas de água no ambiente interno e o contato da água com o ar quente e seco acelera a sua evaporação. Dessa forma, o ar cede calor sensível e as gotículas de água evaporam. Como conseqüência, a temperatura diminui e a umidade do ar aumenta no interior do ambiente. O condicionador de ar convencional, constituído por evaporador, compressor e condensador, refrigera o ar por meio da compressão e da expansão do gás freon. Os dados do interior de cada célula foram automaticamente coletados por meio do Datalogger Campbell Scientific Inc CR10X. As temperaturas de bulbo seco e úmido foram regitradas com sensores termopares tipo T (Cobre-Constantan). A técnica de resfriamento evaporativo atingiu índices adequados de conforto ambiental em períodos de climas quente e seco, demonstrando, assim, ser eficaz em promover a diminuição da temperatura e a umidificação de ambientes internos. Este trabalho sugere, portanto, que a técnica de resfriamento evaporativo pode ser uma alternativa para melhorar as condições térmicas dos espaços de permanência humana com consumo de energia inferior ao do condicionador de ar convencional. / This experimental research aims to compare the evaporative cooling with the conventional air conditioning in terms of levels of humidity, reduction in indoor air temperature, and energy consume. The experiment was conducted in three purpose-built test cells, similar in structure, which were exposed to the same climatic conditions and showed the same indoor air volume rates. Each equipment was installed in one of the test cells, and the remaining cell had no cooling appliances, thus being used as reference standard. The evaporative cooling technique consists of an electrical-mechanical system of forced ventilation which introduces outdoor air into the indoor environment, across a humidifier pad made of cellulose. The forced ventilation spread small drops of water into the indoor environment and the water’s contact with the dry-warm air accelerates the evaporation process. Thus, the air loses sensible heat and the water evaporates. As a result, the air temperature decreases, and the relative humidity increases inside the environment. The conventional air conditioning system, comprises of an evaporator, a compressor and a condenser, cools the air by compressing and expanding Freon gas. The data from each cell was automatically collected by using a Datalogger CR10X. Both dry and wet bulb temperature was measured by using thermocouples type T (Copper-Constantan). The evaporative cooling technique was shown to provide higher levels of human comfort during warm-dry climate, thereby demonstrating that it can be effective in humidifying and constantly replenishing indoor air. This work therefore suggests that the evaporative cooling can be an alternative for improving the conditions of purpose-built environments with lower levels of energy consume when compared with the conventional air-conditioning systems.
183

Termorregulação em cavalos submetidos a diferentes métodos de resfriamento pós-exercício / Thermoregulation in horses undergoing three different post exercise cooling methods

Mariano Etchichury 12 December 2008 (has links)
O presente trabalho teve como objetivo comparar dois métodos alternativos de resfriamento pós-exercício em eqüinos, consistentes no uso de água a temperatura ambiente e de gelo nas extremidades, com o método de hiperresfriamento, usado habitualmente nos cavalos de esporte. A necessidade de métodos de resfriamento mais efetivos se baseia no grande quantidade de cavalos eliminados em provas de resistência no país, relacionada à temperaturas ambiente e umidade relativa elevadas. Para comparações foram usados nove cavalos de lida, três machos castrados e seis fêmeas, mestiços, de 8±2,5 anos e peso médio de 462±33 kg, em dois experimentos, um no mês de maio e outro em julho, de 4 dias de duração cada um, com delineamento em cross-over. Os cavalos foram exercitados com protocolo pré-estabelecido em picadeiro durante 30 minutos, e os tratamentos foram aplicados em Câmara Bioclimática. As variáveis estudadas foram: freqüência cardíaca (FC), freqüência respiratória, temperatura retal (TR), taxa de sudação (SUD), temperatura superficial do pescoço (TSP), temperatura superficial do tórax (TST), temperatura superficial da garupa (TSG), temperatura auricular (TAu) e temperatura da base da cauda (TBC). Foram mensurados valores basais pré-exercício, imediatamente pós-exercício sem tratamento, 5, 10, 15 e 20 minutos após o exercício com tratamento, e 5 e 10 minutos pós-tratamento. Os dados foram analisados por regressão linear, e as médias comparadas tempo a tempo pelo teste T de Student. Houve diferença significativa (p<0,05) entre tratamentos nas variáveis TSP, TST, TSG nos dois experimentos, e na TAu no experimento de maio, mas esta diferença foi somente durante o resfriamento, no final do teste ao minuto 30, 10 minutos após serem interrompidos os tratamentos, não houve diferença em nenhuma variável em nenhum dos dois experimentos. Os dois métodos de resfriamento alternativos aqui propostos não apresentaram diferença alguma com o hiper-resfriamento no minuto 30 do teste. / This study was aimed to compare two alternative cooling methods in horses with hyper cooling method, used usually spot horses. Alternatives method consists in tepid water bath of the entire body, and the use of ice in the limbs. The need of alternatives methods of cooling post exercising horses is based in the huge amount of competitors eliminated from endurance rides in Brazil, related to high humidity and hot environments. Nine Standarbred horses were used, three gelding and six mares, aging 8±2,5 years and weighing 462±33 kg, in two experimental sets, performed in May and in July, during four days each, in a cross over experimental design. Horses were exercised in a planned schedule for 30 minutes, after this were placed in a climatic chamber, were treatments were applied. Heart rate, respiratory rate, rectal temperature, sweating, neck skin temperature, thorax skin temperature, croup skin temperature, auricular temperature and tail skin temperature were measured for comparison. Time used in measurements were pre-exercise, immediately post exercise without cooling, 5, 10, 15 and 20 minutes post exercise with cooling, and 5-10 minutes post cooling. Data was processed using linear regression test, and means at each time were compared using T test. Significant difference (p<0,05) was detected in neck skin temperature, thorax skin temperature and croup skin temperature in both experimental sets, and in auricular temperature in May set, although this difference appeared only during cooling treatments. At the end of the test, in minute 30, no difference among treatments were detected in any measurement at any experimental set. Both alternative cooling methods here proposed made no difference in post exercise body cooling terms, when compared with hyper-cooling method, at minute 30 of the test.
184

Análise de trocadores de calor compactos para desumidificação de ar. / Analysis of compact heat exchanger for air dehumidification.

Paul Fernando Cuadros Gutierrez 01 June 2006 (has links)
O objetivo deste trabalho é realizar uma análise paramétrica do processo de desumidificação de ar comprimido em trocadores de calor compactos com superfícies intensificadoras do tipo aletas deslocadas. A umidade contida no ar comprimido precisa ser retirada do sistema para evitar a formação de condensado nas linhas de distribuição, nos atuadores ou nos dispositivos finais. Utiliza-se o processo de desumidificação por resfriamento onde a temperatura do ar é diminuída até alcançar o ponto de orvalho, resultando em formação de condensado. O desumidificador é constituído por dois trocadores de calor (recuperador e evaporador), sendo cada um deles dividido em duas regiões. Realizou-se a modelagem do processo de transferência de calor para cada um dos trocadores. Utilizou-se o método do potencial de entalpias para determinar os coeficientes globais de transferência de calor de cada trocador. Para a realização da simulação numérica, foi implementado um programa utilizando como ferramenta computacional o programa “Engineering Equation Solver” (EES). O estudo foi feito variando-se os parâmetros geométricos do trocador de calor e verificando sua influência nos coeficientes de transferência de calor, nos calores trocados e nas condições de saída do ar. Primeiramente, cada parâmetro foi analisado individualmente e depois com algumas combinações. Concluiu-se que as dimensões das aletas no recuperador e os comprimentos do recuperador e do evaporador são os parâmetros que mais influenciam nas propriedades do ar comprimido na saída do desumidificador. / The objective of this work is to conduct a parametric analysis of the dehumidification process of compressed air in compact heat exchangers with Offset Strip Fins. The humidity carried by the compressed air should be removed from the system to prevent the condensation in the distribution lines and in the actuators or the final devices. The dehumidification process by cooling occurs when the temperature of the air is diminished until reaching the dew point, resulting in condensation of water vapor. The dehumidifier is constituted by two heat exchangers (recuperator and evaporator), each one of them being divided in two regions. A modeling of the heat and mass transfer process for each heat exchangers, was performed. The enthalpy driving potential method was used to determine the overall heat transfer coefficients of each heat exchanger. The numerical simulation was implemented by using the computational software "Engineering Equation Solver"(EES). The study was made varying the geometric parameters of the heat exchanger and verifying its influences on the heat transfer coefficients, the heat transfer and pressure drop, and the air exit conditions. First, each parameter was analyzed individually and then with some combinations. Its was concluded that the fins dimensions in both regions of the lengths of the recuperator and the evaporator are the parameters that have larger influence on the exit compressed air properties.
185

Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água. / Presentation and comparison of a model based in high mass transfer and supersaturation in a cooling water tower.

Mariana Fernandes 20 December 2011 (has links)
Torres de resfriamento são equipamentos muito utilizados na indústria e que muitas vezes operam sob condições adversas, particularmente, temperatura de água acima dos 50°C na entrada da torre. Nesta condição, tem-se alta taxa de evaporação e eventualmente condição de alto transporte de massa, normalmente não considerado no equacionamento de torres de resfriamento. Apresenta-se assim uma análise comparativa de diferentes métodos de cálculo de torres de resfriamento: Merkel, Poppe e o modelo proposto. No modelo proposto neste estudo, consideram-se os balanços diferenciais de massa e energia e os mecanismos de transporte simultâneo de calor e massa, na condição de alto transporte de massa e de supersaturação do ar, caso o vapor de água condense na forma de névoa. Para os casos em que há saturação do ar, os balanços diferenciais de massa e energia passam a contemplar este fenômeno a partir do momento em que ocorre a saturação. O modelo matemático desenvolvido consiste de equações diferenciais ordinárias e equações auxiliares, e foi implementado em uma interface Matlab. Os principais parâmetros investigados foram: as vazões de água e ar, a temperatura de bulbo úmido do ar, a temperatura da água na entrada da coluna e a altura da torre. A partir das simulações matemáticas, foram obtidos resultados de temperaturas do ar, da água e da umidade do ar ao longo da coluna, para os diferentes métodos. / Cooling towers are equipment widely used in industrial plants, where these operate under severe conditions such as cooling water inlet temperatures above 50oC. Under this condition, there are high evaporation of water and high mass transfer, generally not considered in performance analysis of a cooling tower. This work presents and analyzes the differences between the proposed model and the Merkel and Poppe approaches. The proposed model in this work is based on differential equations for energy and mass balances and on the mechanisms of combined heat and mass transfers, at high mass transfer condition and considering the supersaturated air from the height of the tower that the excess of water vapor condenses as a mist. At the point that the air became supersaturated, the differential equations for energy and mass balances start to consider the supersaturation phenomena. The mathematical model developed in this work is composed by ordinary differential equations and auxiliary equations which were solved at Matlab. The parameters investigated were water and air mass flow rates, air wet bulb temperature, water inlet temperature and tower height. The results of air and water temperatures, humidity air across the tower height are presented for each method analyzed.
186

Qualidade fisiológica de sementes de Brachiaria spp submetidas a condições de armazenamento / Physiological quality of Brachiaria spp. Seeds under storage Conditions

Tonini, Michelle 30 January 2014 (has links)
Made available in DSpace on 2017-07-10T19:23:42Z (GMT). No. of bitstreams: 1 Michelle Tonini.pdf: 883368 bytes, checksum: 34a5d42229bfd1219232464ee0b21f2b (MD5) Previous issue date: 2014-01-30 / Brachiaria spp. seeds are important to the business sector in Brazil, since these forages are largely used, mainly on cattle feeding. It has been a period the sector has grown significantly, commanding the largest domestic and international trading areas. Thus, an increasing demand has been required concerning the supply of seeds with good quality. In order to keep seeds vigor and germination, it is essential a logistic process that involves up from yield until storage. In this context, this work aimed at studying the packaging influence during Brachiaria brizantha e Brachiaria humidicola spp. seeds storage under different temperatures. So, three kinds of packaging (paper, plastic and woven polypropylene) and two temperature conditions (25 °C and cooling) were applied, while seeds were stored for 210 days. The evaluations were monthly obtained for the following parameters: quality of thousand seeds mass, moisture content, germination in sand, dry weight in seedling, viability by tetrazolium test and germination percentage. In order to evaluate the existence of dormancy in seed samples, scarification was carried out with concentrated sulfuric acid to compare data. The results showed that the packaging did not affect seed physiological quality. However, it is necessary to evaluate the initial dormancy before opting for waterproof packaging, because the scarification process may be delayed. The cooling influenced the seeds of Brachiaria Brizantha, Marandu cultivar. It was put forward the development of secondary dormancy, so periods relatively longer for germination were needed. Scarification was effective on breaking dormancy of Brachiaria Brizantha seeds, whose cultivar is Xaraés as well as Brachiaria humidicola, however, when it was applied to seeds with a high germination index, scarification with sulfuric acid has become harmful / Sementes do gênero Brachiaria são importantes para o setor econômico no Brasil, visto a larga escala de utilização dessas forrageiras, principalmente na base de alimentação do rebanho bovino. Nos últimos anos, o setor tem crescido significativamente e comanda o maior mercado interno e externo, além de exigir cada vez mais a oferta de sementes de boa qualidade. Para a manutenção do vigor e da germinação das sementes, é necessária uma logística que envolve desde o processo de produção até o armazenamento. Neste contexto, o objetivo deste trabalho foi avaliar a influência de embalagens no armazenamento de sementes de Brachiaria brizantha e Brachiaria humidícola, sob condições de temperaturas diferenciadas. Para isso, foram utilizados três tipos de embalagens (papel, plástico e polipropileno trançado) e duas condições de temperatura (25 ºC e resfriamento), armazenados por 210 dias. As avaliações foram mensais para os parâmetros de: qualidade de massa de mil sementes, grau de umidade, emergência em areia, massa seca de plântulas, viabilidade pelo teste de tetrazólio e porcentagem de germinação. Para avaliar a existência de dormência nas amostras de sementes, foi empregada a escarificação com ácido sulfúrico concentrado, para comparação de dados. Os resultados mostraram que as embalagens não influenciaram a qualidade fisiológica das sementes. Entretanto, é necessário avaliar a dormência inicial antes de optar por embalagem impermeável, pois o processo de superação de dormência pode ser retardado. O resfriamento influenciou as sementes de Brachiaria brizantha cultivar Marandu. Promoveu-se o desenvolvimento de dormência secundária e foram necessários períodos relativamente maiores para germinação. A escarificação foi eficiente na superação de dormência das sementes de Brachiaria brizantha cultivar Xaraés e Brachiaria humidícola, porém, quando aplicada em sementes com elevado índice de germinação, a escarificação com ácido sulfúrico tornou-se prejudicial
187

Evolução estrutural e térmica de um batólito sin-cinemático no orógenos Neoproterozóico Araçuaí (leste do Brasil) / Structural and thermal evolution of a synkinematic batholith from the Neoproterozoic Araçuaí hot orogen (eastern Brazil)

Mathieu Mondou 20 October 2010 (has links)
A faixa Araçuaí, de idade neoproterozóica, caracteriza-se por apresentar em seu domínio alóctone, uma grande quantidade de intrusões magmáticas, uma crosta parcialmente fundida e rochas de facies granulítica, características de uma geoterma elevada, configurando trata-se de um orógeno quente. A suíte tonalítica Galiléia, alojada em metassedimentos, deformada no estado magmático, representa um grande batólito que influenciou de maneira significativa o comportamento mecânico desta crosta mediana. A Anisotropia de Suscetibilidade Magnética (ASM) medida nesse batólito e usada para um estudo de petrotrama, combinado com uma investigação detalhada sobre a mineralogia magnética, permitiu caracterizar o comportamento paramagnético da Suíte Galiléia e, adicionalmente, trazer informações sobre uma deformacão complexa em 3D. As estruturas observadas se desenvolveram em um magma viscoso resultado de uma combinação da tectônica tangencial induzidas por compressão e forças gravitacionais devido ao peso da crosta sobrejacente. A cinemática do batólito é compatível com aquela descrita para as rochas dúcteis da faixa. Datações U/PB em zircões e monazitas e 40Ar/39Ar em anfibólios, moscovitas e biotitas permitiram definir a evolução termal do batólito Galiléia e de seus metassedimentos hospedeiros e trazer informações sobre o período deformacional. O batólito Galiléia colocouse durante um importante evento magmático, termal e tectônico a ~ 580 Ma. A temperatura permaneceu alta durante os primeiros ~ 50Ma da evolução termal, promovendo uma deformação quase constante do batólito no estado magmático durante várias dezenas de milhões de anos. Tais condições de alta temperatura e cinemática deformacional, estável durante períodos prolongados de tempo, são característicos de orógenos quentes. A taxa de resfriamento vagarosa de ~ 10°C/Ma sugere que após ~500Ma a taxa de exumação foi muito lenta, provavelmente ocasionada apenas pela erosão. / The allochtonous domain of the Neoproterozoic Araçuaí belt involves large amounts of magma, widespread partial melting, granulitic facies and high geotherm, characterising this belt as a hot orogen. The Galiléia tonalitic suite, emplaced within host metasediments and deformed at magmatic state, represents a huge batholith that strongly influenced the mechanical behaviour of this middle crust. The anisotropy of magnetic susceptibility (AMS) measured through this batholith and used as a petrofabric proxy, combined to a detailed magnetic mineralogy investigation, permitted to characterize the paramagnetic behaviour of the Galiléia suite and therefore to highlight a complex 3D strain deformation. The observed structures developed within the viscous magma resulted from a combination of tangential tectonics induced by the compression, and gravitational forces arising from the load of the overlying crust. The kinematics of the batholith is compatible with that already described for ductile rocks of hot orogens. U/Pb dating on zircons and monazites together with 40Ar/39Ar dating on amphiboles, muscovites and biotites permitted to define the thermal evolution of the Galiléia batholith and its host metasediments and constrain the timing of the deformation. The Galiléia batholith emplaced during an important magmatic, tectonic and thermal event at ~580 Ma. Temperature remained high during the first ~50 Ma of the thermal evolution, promoting a seemingly constant deformation of the batholith at magmatic state during several tens of millions years. Such high temperature conditions and stable deformation kinematics during protracted periods of time are supposed to be characteristic of hot orogen. The slow cooling rate of ~10°C/Ma evidenced after ~500 Ma probably indicate a very slow exhumation probably only conducted by erosion.
188

Estudo do efeito da adição de diésteres em fluidos industriais de origem vegetal e suas propriedades / Effect of diesters additions on the properties of industrial fluids vegetable oil based

Adriana Marques 29 March 2012 (has links)
Os óleos vegetais vêm sendo estudados como substitutos aos minerais em várias aplicações industriais, em particular no resfriamento de aços, no processo de tratamento térmico de têmpera. Este trabalho trata do estudo das características de viscosidade e propriedades de resfriamento de óleos vegetais e de formulações feitas a partir desses óleos com diésteres: Bis (2-etilhexil) adipato DOA, Bis (2-etilhexil) sebacato DOS e Diiso Tridecil adipato DITA, nas proporções de 2,5% e 5,0% (m/m). Realizou-se também nos óleos vegetais, sem aditivos, uma avaliação prévia da estabilidade oxidativa feita por RMN, baseando-se nas proporções de ácidos graxos saturados e insaturados presentes na cadeia. Avaliações foram também feitas para formulações com óleo de soja após o processo de envelhecimento acelerado. Os resultados indicaram como sendo o óleo de coco, o de maior estabilidade oxidativa. Os óleos de amendoim e soja apresentaram menores variações de viscosidade com a temperatura, caracterizados pelos menores valores do coeficiente de Walther (B). Das formulações estudadas, no estado não oxidado, a adição de 2,5% de DOS ao óleo de soja foi a que proporcionou maiores taxas máximas e camada de vapor menos estável. Após a oxidação de 48 horas, a composição de óleo de soja adicionado a 5,0% de DOA foi a que sofreu menores alterações comparadas do estado não oxidado. / Vegetable oils have been studied in the replacement of mineral oils in many industrial applications particularly on the quenching steel in the heat treatment process. This work presents studies conducted to vegetable oils in terms of viscosity characteristics and cooling behavior. Such studies incorporate also formulations on vegetable oil based by diesters additions [Bis (2-etylhexyl) Adipate - DOA, Bis (2-etylhexyl) Sebacate DOS, Diiso Trydecil Adipate DITA] in the proportions of 2.5 and 5.0 % (m/m). Oxidation stability was evaluated by NMR performed in the vegetable oil without diesters additions. This evaluation was based in the satured and insatured compounds presented in the vegetable oil chain. Similar evaluations were also performed for formulations based on the soybean oil, before and after the accelerated oxidation tests. Results indicated coconut oil as the most stable in terms of oxidation. Peanut oil and soybean oil shown minor alterations on the viscosity values when the raise of temperature, since they presented lower Walther coefficient (B). Comparing the formulations soybean oil based in the not oxidized condition, the addition of 2,5% DOS was that shown greater maximum cooling rates (CRmax) and less stable vapour phase. After accelerated oxidation tests (48 hours), formulation with 5% DOA (soybean oil based) was that presented minor variations in terms of cooling parameters compared with not oxidized condition.
189

Resfriamento de ambientes utilizando sistema regenerativo com leito de pedras

Cavalcanti, Eduardo J. Cidade 02 August 2018 (has links)
Orientador : Caio Glauco Sanchez / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-02T07:50:13Z (GMT). No. of bitstreams: 1 Cavalcanti_EduardoJ.Cidade_D.pdf: 5685689 bytes, checksum: 8ec4e75f6488bbefb53d768d505269cb (MD5) Previous issue date: 2001 / Resumo: Foi avaliado um sistema de refrigeração não-convecional de maneira a se verificar sua real possibilidade como um sistema alternativo aos sistemas de resfriamento convencionais de ambientes como o aparelho unitário de ar-condicionado. Sistemas de refrigeração não-convecionais são alternativas para refrigerar ambientes, principalmente durante o verão, de forma mais econômica. O sistema regenerativo de leito de pedras úmido é uma unidade de alta eficiência de troca térmica, onde o ar ambiente transfere calor escoando através do leito de pedras. Esse sistema é utilizado em escolas do sul da Austrália devido a seu desempenho tanto no verão (resfriando), quanto no inverno (aquecendo) com baixo custo operacional (apenas o consumo de ventilador) e com ar sempre renovado. Sua desvantagem é o aumento excessivo da umidade do ar, o que pode se tornar uma vantagem em regiões secas. O trabalho foi composto de duas partes. A primeira foi o desenvolvimento de um modelo teórico para simulação do sistema e verificação do seu desempenho e estimativa da influência dos parâmetros: fração de vazio do regenerador, ciclos de operação, temperatura da água de alimentação do resfriador evaporativo, calor específico do material utilizado como regenerador térmico. A segunda parte foi a determinação experimental do desempenho de um protótipo construído na Faculdade de Engenharia Mecânica da UNICAMP através da determinação experimental da efetividade do regenerador e do resfriador evaporativo (componentes dos sistema estudado). A simulação do modelo teórico foi importante para otimizar o projeto térmico do sistema e verificar o seu desempenho de acordo com os parâmetros analisados. Foi realizada análise da sensibilidade dos parâmetros citados e foi observada uma forte influência da fração de vazio do regenerador, ciclos de operação e do calor específico do material utilizado como regenerador térmico no sistema. A temperatura da água de alimentação do resfriador evaporativo possui uma influência desprezível no sistema. Os dados do modelo e as medidas experimentais foram comparados e foi observado uma melhor precisão para ciclos pequenos, principalmente para ciclos de 5 minutos, do que para ciclos maiores / Abstract: A passive cooling system was evaluated in order to verify, its real possibility as an alternative system to the conventional cooling systems like single air conditioning unit. Passive cooling system can be an alternative for building cooling system, mainly during the summer, m a more econOIIDC way. The wet rock bed regenerative system presents a high heat exchanger effectiveness, due to the heat transfer between atmospheric air and water flowing in matrix of rock bed. That system is commonlY applyed in schools of the south Australia due to its good performance in the summer (cooling), as in the winter (heating) with low operational cost Gust the fan consumption) and with air always renewed. 1ts disadvantage is the excessive increase of the air humidity, otherwise this fact becomes an advantage for dry environrnents. The work was composed by two parts. The first one was the development of a theoretical model for the system simulation to verify its performance and the influence of the parameters: void fraction of regenarator, period of time, water temperature, specific heat of the regenerator material. The second part was the experimental determination of the performace of a prototype system built in the college of Mechanical Engineering at UNlCAMP through experimental determination of regenerator and evaporative cooler effectiveness (components ofthe studied system). The theoretical model simulation was important for thermal design optimization and verification of the system performance according to analyzed parameters. Sensibility analysis was made for the cited parameters and was observed a high influence of void fTaction of regenarator, period of time and specific heat of the regenerator material on the system. The feeding water temperature of evaporative cooler has a negligible influence on the system. The data of the mode! and the experimental measures were compared and was observed a better accuracy for small period main1y for period of 5 minutes as larger period / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica
190

Estudos espectroscópicos em átomos e moléculas : cálculos de forças de osciladores e tempos de vida para íons de Si, medidas de momento de recuo de íons em átomos de Cs resfriados a laser e medidas de multicoincidência em moléculas de N2 e O2

Coutinho, Lucia Helena 25 September 2003 (has links)
Orientador: Arnaldo Naves de Brito / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T17:45:05Z (GMT). No. of bitstreams: 1 Coutinho_LuciaHelena_D.pdf: 12958301 bytes, checksum: d03d95db8e1450f541121cc8a86cdd39 (MD5) Previous issue date: 2003 / Resumo: Este trabalho apresenta estudos em física atômica e molecular, tanto teóricos quanto experimentais. Foram realizados cálculos de forças de osciladores ponderadas para os seguintes íons de silício: Si I, Si XI, Si XII e Si XIII. Estes cálculos são realizados em uma aproximação relativística multiconfiguracional Hartree-Fock. Os parâmetros eletrostáticos foram otimizados por um procedimento de mínimos quadrados, para um melhor ajuste com dados experimentais de níveis energéticos e comprimentos de onda de transições. Um outro trabalho na área de física atômica foi a construção de um novo espectrômetro de massa por tempo de vôo para medidas de momento de recuo de íons em átomos resfriados com laser, após fotoionização por radiação síncrotron. Este é um trabalho pioneiro que abre uma nova linha de pesquisa. Com este equipamento foram realizadas medidas de momento de recuo em íons Cs + , e foi possível também a obtenção do parâmetro de assimetria b para as energias estudadas, entre 13 e 40 eV. Os estudos em física molecular compreenderam medidas de multicoincidência elétron-íon (PEPICO ¿ PhotoElectron-PhotoIon COincidence) e elétron-íon-íon (PEPIPICO ¿ PhotoElectron-PhotoIon-PhotoIon COincidence) em N2 e O2 próximas aos limiares de ionização N 1s e O 1s, respectivamente. Espectros de produção total de íons também foram obtidos para estas moléculas. Foram realizadas também medidas de coincidência elétron-íon (PEPICO) para alguns aminoácidos em sua forma gasosa pela primeira vez / Abstract: This thesis comprises atomic and molecular physics studies, both theoretical and experimental. Weighted oscillator strengths and lifetimes were calculated for the following silicon ions: Si I, Si XI, Si XII and Si XIII. The calculations were carried out in a multiconfiguration Hartree-Fock relativistic aproach. The eletrostatic parameters were optimized by a least-squares procedure in order to improve the adjustment to experimental energy levels and transitions wavelengths. Another work in the atomic physics area was the construction of a new time-of-flight spectrometer to measure ion recoil momentum in laser-cooled atoms, after photoionization by synchrotron radiation. This is a pioneering work that opens up a new research area. With this equipment ion recoil momentum were measured for the Cs + ion, and it was possible to determine the b assymetry parameter in the energy range studied, 13 to 40 eV. The molecular physics studies comprised multicoincidence measurements (PEPICO and PEPIPICO) in N2 and O2 near the ionization thresholds N 1s and O 1s, respectively. Total Ion Yield (TIY) spectra were also obtained for these molecules. Coincidence spectra (PEPICO) for some aminoacids in their gas phase were also taken for the first time / Doutorado / Física / Doutor em Ciências

Page generated in 0.0526 seconds