• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 1
  • Tagged with
  • 193
  • 193
  • 136
  • 114
  • 87
  • 80
  • 74
  • 71
  • 57
  • 50
  • 50
  • 48
  • 47
  • 45
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etiologia e perfil de resist?ncia de bact?rias isoladas de otite externa em c?es

Carvalho, Leonardo C?sar Andriola 19 May 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-02-15T11:56:11Z No. of bitstreams: 1 LeonardoCesarAndriolaCarvalho_DISSERT.pdf: 1817208 bytes, checksum: 513d53ff5b107ffefc3220ff658f24fa (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-02-16T16:04:39Z (GMT) No. of bitstreams: 1 LeonardoCesarAndriolaCarvalho_DISSERT.pdf: 1817208 bytes, checksum: 513d53ff5b107ffefc3220ff658f24fa (MD5) / Made available in DSpace on 2018-02-16T16:04:39Z (GMT). No. of bitstreams: 1 LeonardoCesarAndriolaCarvalho_DISSERT.pdf: 1817208 bytes, checksum: 513d53ff5b107ffefc3220ff658f24fa (MD5) Previous issue date: 2017-05-19 / A otite externa canina ? uma enfermidade relevante na cl?nica veterin?ria. Considerando a elevada frequ?ncia de atendimentos de c?es com otite externa bacteriana, objetivou-se identificar a frequ?ncia etiol?gica da otopatia e tra?ar o perfil de resist?ncia dos Staphylococcus Meticilina Resistentes (SMR) e enterobact?rias produtoras de Beta-Lactamases de Espectro Estendido (ESBL) em pacientes ambulatoriais e de internamento. As amostras foram submetidas a isolamento prim?rio, testes de susceptibilidade ? antimicrobianos e de resist?ncia bacteriana. Para os Staphylococcus sp. aplicou-se o Teste D (Disk Test) e o teste de Resist?ncia ? Meticilina (Met-25). Nas cepas positivas para o Met-25 foi feita Rea??o em Cadeia da Polimerase (PCR) para detec??o do gene mecA. Para estirpes positivas na PCR foi determinada a Concentra??o Bactericida M?nima (CBM) do gluconato de clorexidina. Os grupos bacterianos isolados das 140 amostras coletadas foram: Staphylococcus sp. (122 ? 49,38%), Pseudomonas sp. (22 ? 8,91%), enterobact?rias (19 ? 7,69%), Enterococcus sp. (17 ? 6,88%) e Acinetobacter sp. (12 ? 4,86%). Foram isoladas 14 cepas de SMR (11,47%) e todas continham o gene mecA. Observou-se que 14 Staphylococcus sp. foram Teste D positivo. Para os Staphylococcus coagulase positiva (SCP) a CBM foi de 500.000?g/mL (0,5%) enquanto que para os Staphylococcus coagulase negativa (SCN) o valor da CBM foi de 62.500?g/mL (0,0625%). Detectou-se 3 cepas de enterobact?rias ESBL. Os antimicrobianos mais efetivos para Staphylococcus sp. foram: Linezolida (100%), Rifampicina (94,26%) e Cloranfenicol (92,62%). Para Pseudomonas sp.: Cefepime (100%), Imipenem (100%) e Meropenem (100%). Para as enterobact?rias: Ertapenem (100%), Imipenem (100%) e Cefotaxima (84,21%). Para Enterococcus sp.: Cloranfenicol (100%), Linezolida (94,12%) e Vancomicina (88,24%). Para Acinetobacter sp.: Imipenem (100%), Meropenem (100%) e Ticarcilina com Clavulanato (91,67%). Apesar do gene mecA e de enterobact?rias produtoras de ESBL terem baixa ocorr?ncia neste estudo, existe a necessidade de um monitoramento constante em cepas isoladas de animais dom?sticos. Cultura bacteriol?gica e os testes de suscetibilidade aos agentes antimicrobianos s?o de grande import?ncia na rotina cl?nica veterin?ria para garantir o sucesso do tratamento de infec??es otol?gicas caninas. / The canine external otitis is a relevant disease regarding veterinary clinic. Considering the high frequency of treatment of dogs with external bacteria otitis, this research aims to identify the etiological frequency of otopathy and trace the resistance profile of the Methicillin Resistant Staphylococcus (MRS) and enterobacteria that produce Extended Spectrum Beta-Lactamase (ESBL) in outpatients and internment patients. The samples were submitted to primary isolation, tests of antimicrobial susceptibility and bacterial resistance. For the Staphylococcus sp. the Disk Test was applied along with the resistance test to Methicillin (Met-25). In the positive strains for Met-25, a Polimerase Chain Reaction (PCR) was applied to detect the mecA gene. For the PCR positive strains, a Minimum Bactericidal Concentration (MBC) of chlorhexidine gluconate was determined. The isolated bacterial groups of the 140 samples collected were: Staphylococcus sp. (122 ? 49.38%), Pseudomonas sp. (22 ? 8.91%), enterobacteria (19 ? 7.69%), Enterococcus sp. (17 ? 6.88%) and Acinetobacter sp. (12 ? 4.86%). 14 MRS strains (11.47%) were observed and all off them had the mecA gene. 14 Staphylococcus sp. were Disk Test positive. Concerning the positive Staphylococcus coagulase, the MBC was 500.00?g/mL (0.5%) whereas for the negative Staphylococcus coagulase the MBC value was 62.500?g/mL (0.0625%). 3 ESBL enterobacteria strains were detected. The more effective antimicrobial for the Staphylococcus sp. were: Linezolid (100%), Rifampicin (94.26%) and Chloramphenicol (92.62%). Regarding the Pseudomonas sp.: Cefepime (100%), Imipenem (100%) and Meropenem (100%). Regarding the enterobacteria: Ertapenem (100%), Imipenem (100%) and Cefotaxime (84.21%). Regarding the Enterococcus sp.: Chloramphenicol (100%), Linezolid (94.12%) and Vancomycin (88.24%). Regarding the Acinetobacter sp.: Imipenem (100%), Meropenem (100%) and Ticarcillin with Clavulanate (91.67%). Although the mecA gene and the enterobacteria that produce ESBL are briefly presented in this research, there is a need for constant monitoring of isolated strains in domestic animals. The bacteriological growth and the susceptibility tests in the antimicrobial agents are of great importance in the veterinary clinic routine in order to insure the success in treating canine otological infections.
2

Parafuso prot?tico de reabilita??es dent?rias sobre implantes :estudo mec?nico e an?lise pelo m?todo de elementos finitos

Barbosa, Gustavo Frainer 17 March 2006 (has links)
Made available in DSpace on 2015-04-14T13:58:37Z (GMT). No. of bitstreams: 1 346986.pdf: 3178845 bytes, checksum: 85423caf5393f07801ed0d94b0ba85c8 (MD5) Previous issue date: 2006-03-17 / O presente trabalho teve como objetivo desenvolver estudos mec?nicos sobre o parafuso prot?tico de reabilita??es dent?rias sobre implantes. Isto porque, este componente restaurador tem apresentado um n?mero expressivo de falhas, afrouxamento e/ou fratura, em especial os parafusos prot?ticos de uma empresa nacional com amplo alcance no mercado, a Conex?o Sistemas de Pr?tese?. Para que fosse atingido um resultado fidedigno e satisfat?rio, o trabalho foi dividido em duas etapas distintas. Numa primeira etapa, ap?s um amplo levantamento de informa??es mec?nicas e biomec?nicas que envolvem o complexo coroa, pilar, cilindro e parafuso prot?ticos, um programa em forma de planilha do Excel foi desenvolvido para que uma an?lise da especifica??o do torque recomendado pelo fabricante pudesse ser efetuada. Al?m disto, pode-se confirmar quais s?o as caracter?sticas mec?nicas necess?rias que devem estar presentes no parafuso prot?tico para que se possa desenvolver um determinado torque. Na segunda etapa proposta neste trabalho, foi utilizado um programa de an?lise por elementos finitos para verificar os locais onde ocorrem concentra??es de tens?o no parafuso prot?tico. Para isto todo o complexo prot?tico implantar foi constru?do e submetido ao teste de for?a, reproduzindo, assim, o mais pr?ximo poss?vel a realidade encontrada in vivo durante a aplica??o de for?as mastigat?rias. Os resultados obtidos na primeira etapa do trabalho demonstraram que o torque recomendado pelo fabricante est? dentro das reais necessidades do conjugado. E que a qualidade deste torque est? relacionada ao processo de fabrica??o do parafuso, como tamb?m, ao seu coeficiente de atrito. Na segunda etapa foi verificado que as ?reas onde ocorre maior concentra??o de tens?o est?o localizadas na uni?o entre a haste e a cabe?a do parafuso. Este ponto favorece o aparecimento de trincas que levar?o a fratura do material. Portanto, as solu??es propostas para o problema, dentro das limita??es deste trabalho, s?o uma adequa??o do processo de fabrica??o, como tamb?m uma pequena mudan?a no design do parafuso prot?tico de reabilita??es dent?rias sobre implantes osseointegrados. Isto feito, se estar? indo ao encontro da busca di?ria dos pacientes e dos profissionais reabilitadores, ou seja, da excel?ncia nos tratamentos propostos e realizados.
3

Efeito da espessura e do material restaurador na resist?ncia ? fratura de facetas oclusais confeccionadas em CAD/CAM

Andrade, Jonas Pereira 19 January 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-26T14:49:22Z No. of bitstreams: 1 DIS_JONAS_PEREIRA_ANDRADE_PARCIAL.pdf: 141765 bytes, checksum: 99338991681873f9d3d7028d9e7cdfa9 (MD5) / Made available in DSpace on 2017-06-26T14:49:22Z (GMT). No. of bitstreams: 1 DIS_JONAS_PEREIRA_ANDRADE_PARCIAL.pdf: 141765 bytes, checksum: 99338991681873f9d3d7028d9e7cdfa9 (MD5) Previous issue date: 2017-01-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The aim of the study was to evaluate, in vitro, the fracture resistance of occlusal veneers, made by CAD/CAM, with Lava Ultimate, e.max CAD and Vita Enamic materials in thicknesses of 0.6 mm and 1.5 mm. Seventy third human sound molars were randomly divided into seven groups (n = 10) according to the variables material and thickness, with the sound teeth as control. The root of the teeth was embedded into a self-cured acrylic resin and the teeth were prepared to simulate advanced erosion of the occlusal surface. The occlusal veneers were made using CAD-CAM technology, being luted to the preparation with adhesive systems and resin cements. After storage in distilled water at 37 ?C for 24 h, the samples were submitted to mechanical cyclic loading (1 million cycles at 100 N load). Subsequently, the sound teeth and the samples with the occlusal veneers were submitted to the fracture resistance test in a universal testing machine with crosshead speed of 1 mm/min. The failures were classified as reparable and irreparable. According to two-way ANOVA, the interaction between material and thickness was significant (p=0.013). The highest fracture resistance was obtained for the e.max CAD in the thickness of 1.5 mm (4995 N), being statistically superior to the other groups (p <0.05). The lowest fracture resistance was obtained for Vita Enamic at 0.6 mm thickness (2973 N), not being significantly different from e.max CAD 0.6 mm (3067 N), Lava Ultimate 0.6 mm (3384 N), Vita Enamic 1.5 mm (3540 N) and Lava Ultimate 1.5 mm (3584 N) (p>0.05). According to one- way ANOVA, the fracture resistance of the sound teeth (3991 N) did not differ significantly from the teeth with occlusal veneers (p> 0.05). The failures were predominantly repairable, except for sound teeth and Lava Ultimate 1.5 mm. The Lava Ultimate, e.max CAD and Vita Enamic occlusal veneers, in the thicknesses of 0.6 mm and 1.5 mm, showed fracture resistance exceeding the maximum masticatory forces. / O objetivo do estudo foi avaliar, in vitro, a resist?ncia ? fratura de facetas oclusais, confeccionadas por CAD/CAM, com os materiais Lava Ultimate, e.max CAD e Vita Enamic nas espessuras de 0,6 mm e 1,5 mm. Setenta terceiros molares humanos h?gidos foram aleatoriamente divididos em sete grupos (n=10) de acordo com as vari?veis material e espessura, tendo os dentes h?gidos como controle. A raiz dos dentes foi inserida em resina acr?lica quimicamente ativada e os dentes receberam um preparo para simular eros?o avan?ada da superf?cie oclusal. As restaura??es oclusais foram confeccionadas por meio da tecnologia CAD-CAM, sendo cimentadas ao preparo com sistemas adesivos e cimentos resinosos. Ap?s armazenagem em ?gua destilada a 37 ?C por 24 h, as amostras foram submetidas ? ciclagem mec?nica (1 milh?o de ciclos com carga de 100 N). Na sequ?ncia, os dentes h?gidos e as amostras com as facetas oclusais foram submetidas ao ensaio de resist?ncia ? fratura em m?quina de ensaio universal com velocidade de 1 mm/min. As falhas foram classificadas em repar?veis e irrepar?veis. De acordo com ANOVA de duas vias, a intera??o entre material e espessura foi significativa (p=0,013). A maior resist?ncia ? fratura foi obtida para o e.max CAD na espessura de 1,5 mm (4995 N), sendo estatisticamente superior aos demais grupos (p<0,05). A menor resist?ncia ? fratura foi obtida para o Vita Enamic na espessura de 0,6 mm (2973 N), n?o diferindo estatisticamente do e.max CAD 0,6 mm (3067 N), Lava Ultimate 0,6 mm (3384 N), Vita Enamic 1,5 mm (3540 N) e Lava Ultimate 1,5 mm (3584 N) (p>0,05). De acordo com ANOVA de uma via, a resist?ncia ? fratura dos dentes h?gidos (3991 N) n?o diferiu estatisticamente dos dentes com facetas oclusais (p>0,05). As falhas foram predominantemente do tipo repar?vel, com exce??o dos dentes h?gidos e Lava Ultimate 1,5 mm. As facetas oclusais em Lava Ultimate, e.max CAD e Vita Enamic, nas espessuras de 0,6 mm e 1,5 mm, demonstraram resist?ncia ? fratura que excede as for?as mastigat?rias m?ximas.
4

Identifica??o de genes diferencialmente expressos em h?bridos de Eucalyptus inoculados com isolados de Ceratocystis fimbriata / Identification of genes differentially expressed in hybrids of Eucalyptus inoculated with Ceratocystis fimbriata isolateds

Marques, Ariadne 08 August 2013 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-01-06T11:29:59Z No. of bitstreams: 2 ariadne_marques.pdf: 1829125 bytes, checksum: 01fca719846b682abc79cca9f78f836a (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-01-06T11:30:33Z (GMT) No. of bitstreams: 2 ariadne_marques.pdf: 1829125 bytes, checksum: 01fca719846b682abc79cca9f78f836a (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-01-06T11:31:10Z (GMT) No. of bitstreams: 2 ariadne_marques.pdf: 1829125 bytes, checksum: 01fca719846b682abc79cca9f78f836a (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-01-06T11:31:10Z (GMT). No. of bitstreams: 2 ariadne_marques.pdf: 1829125 bytes, checksum: 01fca719846b682abc79cca9f78f836a (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2013 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / O Ceratocystis fimbriata Ellis & Halsted ? um fitopat?geno vascular de ampla distribui??o geogr?fica e gama de hospedeiros. A murcha de Ceratocystis em Eucalyptus ? considerada de dif?cil controle devido ao seu car?ter sist?mico e a variabilidade gen?tica dos isolados. O plantio de material resistente ? a principal forma de controle desta doen?a. No entanto, a obten??o de material gen?tico resistente pode demandar longos per?odos em um programa de melhoramento. A identifica??o de gen?tipos resistentes dentre os clones utilizados comercialmente pode ajudar a abreviar o tempo necess?rio ao melhoramento. Assim, objetivou-se avaliar a resist?ncia de clones de eucalipto ? murcha de Ceratocystis, analisar as respostas ecofisiol?gicas desses clones sob infec??o e fornecer suporte ao processo de melhoramento gen?tico para tal caracter?stica. Foram avaliados 27 clones de resist?ncia desconhecida e 2 clones caracterizados como resistente e suscet?vel ? murcha de Ceratocystis, todos inoculados artificialmente com isolados de C. fimbriata. Os 27 clones apresentaram, aos 50 dias ap?s inocula??o, varia??o quanto ? resist?ncia ? doen?a. Os dois clones de resist?ncia conhecida tiveram crescimento, ?ndice de clorofila e efici?ncia qu?ntica do fotossistema II (Fv/Fm) avaliados em quatro diferentes tempos. As vari?veis analisadas apresentaram potencial para uso na avalia??o da resist?ncia/suscetibilidade de gen?tipos de Eucalyptus spp. ? murcha de Ceratocystis. O clone resistente (R) e o suscet?vel (S) foram utilizados para a constru??o de uma biblioteca subtrativa supressiva. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Ci?ncia Florestal, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2013. / ABSTRACT The Ceratocystis fimbriata Ellis & Halsted is a vascular phytopathogen of wide geographic distribution and host range. Ceratocystis wilt in Eucalyptus is considered difficult to control due to its systemic character and the genetic variability of the isolated. Planting resistant material is the main way to control this disease. However, the acquisition of genetic material resistant may require long periods in a breeding program. The identification of resistant genotypes among clones used commercially can help shorten the time needed to improve. The aim was to evaluate the resistance of eucalyptus clones to Ceratocystis wilt, analyze the ecophysiological responses of these clones under infection and provide support to the process of breeding for this trait. We evaluated 27 clones of unknown resistance and 2 clones characterized as resistant and susceptible to Ceratocystis wilt, all artificially inoculated with isolates of C. fimbriata. The 27 clones showed, 50 days after inoculation, variation in disease resistance. The two clones of known resistance grew, chlorophyll content and quantum efficiency of photosystem II (Fv / Fm) evaluated at four different times. The variables analyzed showed potential for use in the evaluation of the resistance/susceptibility of genotypes of Eucalyptus spp. to Ceratocystis wilt. The clone resistant (R) and susceptible (S) were used for the construction of a suppressive subtractive library.
5

Influ?ncia do tratamento superficial e da ciclagem mec?nica na resist?ncia de uni?o ao cisalhamento entre cer?mica feldsp?tica e resina composta fotopolimerizavel

Dondoni, Marilson 16 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:52Z (GMT). No. of bitstreams: 1 430600.pdf: 1425866 bytes, checksum: a6284b0edf71e30994f389b10f22f4b4 (MD5) Previous issue date: 2011-03-16 / A cer?mica ? o material restaurador com melhores propriedades est?ticas utilizado na odontologia. Associada a est?tica, outras in?meras propriedades tornam esse material consagrado na odontologia restauradora. Por?m, a cer?mica possui como limita??o um alto potencial de fratura. A substitui??o total de uma restaura??o fraturada muitas vezes ? invi?vel, principalmente quando a pr?tese est? bem adaptada e a fratura n?o ? extensa. Com isso, pode-se lan?ar m?o de reparar a superf?cie da cer?mica fraturada intra-oralmente com resina composta fotopolimeriz?vel. Este estudo teve o objetivo de avaliar a influ?ncia do tratamento superficial e da cilcagem mec?nica na resist?ncia de uni?o ao cisalhamento entre cer?mica feldsp?tica e resina composta fotopolimeriz?vel. Os tratamentos superficiais utilizados foram: asperiza??o com ponta damantada, condicionamento ?cido, jateamento com ?xido de alum?nio e associa??o de jateamento com condicionamento ?cido. Concluiu-se que para um ?ndice de confian?a de 95%, tanto os tratamentos superficiais utilizados, assim como a ciclagem mec?nica, n?o exerceram influ?ncia na resist?ncia de uni?o entre cer?mica feldsp?tica e resina composta fotopolimeriz?vel.
6

An?lise da resist?ncia ao cisalhamento de reparos em cer?micas ap?s diferentes tratamentos de superf?cie

Bettinelli, Juliana Doncatto 22 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:19Z (GMT). No. of bitstreams: 1 446575.pdf: 1714245 bytes, checksum: 92b3a7a5b5c9c607087a2af823b53843 (MD5) Previous issue date: 2013-01-22 / With growing concern with aesthetics in dentistry, have developed various types of ceramic systems. However, remember that, despite the excellent aesthetic characteristics and biocompatibility of the ceramic material is friable unable to withstand plastic deformation under stress. Repairs composite resin can prevent the replacement of a prosthetic fracture. The aim of this study was to determine the shear strength of ceramic repairs after different treatments. The low level laser has been used in dental treatments aiming at improving the cicatricial repair tissue, however this study evaluated results in irradiation of a low intensity laser surface treatment as used in ceramics. The hydrofluoric acid and blasting with aluminum oxide are commonly used in surface treatments in clinical daily. Forty ceramic discs were divided into four groups and with (n = 10) were prepared with the ceramic Noritake EX-3 (Groups E) and another forty discs, were made with the system Noritake Cerabien (Group C). The ceramic discs were fabricated from a metallic mold polytetrafluoroethylene (PTFE) and included individually at the center of a ring of polyvinyl chloride (PVC), using acrylic resin. The groups were divided according to the group: Group E1 and C1: laser application, Grupo E2 and C2: etching with hydrofluoric acid 10%, Group E3 and C3: blasting with aluminum oxide, Group E4 and C4: roughened with carbide silicon grit # 400 (control). All ceramic discs were standardized with roughened with silicon carbide grit # 400, received application of a layer of union agent for ceramics (Silano, Dentsply, Petr?polis, RJ, Brazil) and a layer of adhesive (Single Bond 2 - Adhesive, 3M ESPE, St. Paul, MN, USA). In the center of the disk ceramic block was manufactured in composite microhybrid (Charisma, Heraeus Kulzer, Hanau, Germany). Each group was maintained at 100% humidity at 37 ? C for one to four weeks in an oven to culture. For tests on shear was used Universal Testing Machine Model DL 2000 (EMIC, S?o Jos? dos Pinhais, PR, Brazil). Data were statistically analyzed with the aid of SPSS 17.0 and analysis of variance with repeated measures followed by the Bonferroni test. The blasting with aluminum oxide showed the highest resistance to shear at the interface between the composite and ceramic EX3, and the same occurred in Cerabien pottery, but pottery EX3 with the storage time of 1 week and ceramic Cerabien with time storage of 4 weeks. The blasting with aluminum oxide surface treatment that was presented better results in both types of ceramics coverage surveyed. The storage time of 4weeks had no significant influence in this study. / Com a crescente preocupa??o na Odontologia com a est?tica, t?m-se desenvolvido v?rios tipos de sistemas cer?micos. Contudo, conv?m lembrar que, apesar das excelentes caracter?sticas est?ticas e de biocompatibilidade, a cer?mica ? um material fri?vel incapaz de suportar deforma??o pl?stica sob tens?o. Reparos em resina composta podem evitar a substitui??o de uma pr?tese com fratura. O objetivo deste trabalho foi verificar a resist?ncia ao cisalhamento de reparos em cer?mica ap?s diferentes tratamentos. O ?cido hidrofluor?drico e o jateamento com ?xido de alum?nio s?o comumente usados nos tratamentos de superf?cie na cl?nica di?ria. O laser de baixa pot?ncia tem sido utilizado em tratamentos odontol?gicos visando melhorar o reparo cicatricial nos tecidos, por?m este estudo avaliou resultados na irradia??o de um laser de baixa intensidade utilizado como tratamento de superf?cie em cer?micas. Quarenta discos de cer?mica, divididos em quatro grupos e com ( n=10) foram confeccionados com a cer?mica Noritake EX-3 (Grupos E) e outros quarenta discos, foram confeccionados com o sistema Noritake Cerabien (Grupos C). Os discos de cer?mica foram confeccionados a partir de uma matriz bipartida de politetrafluoretileno (PTFE) e inclu?dos individualmente no centro de um anel de policloreto de vinila (PVC), utilizando-se resina acr?lica autopolimeriz?vel. Os grupos foram divididos aleatoriamente de acordo com o grupo: Grupo E1 e C1: aplica??o do laser, Grupo E2 e C2: condicionamento com ?cido hidrofluor?drico 10%, Grupo E3 e C3: jateamento com ?xido de alum?nio, Grupo E4 e C4: asperiza??o com carbeto de sil?cio granula??o # 400 (controle). Todos os discos de cer?mica foram padronizados com asperiza??o com carbeto de sil?cio granula??o # 400, receberam aplica??o de uma camada de agente uni?o para cer?mica (Silano, Dentsply, Petr?polis, RJ, Brasil) e uma camada de adesivo (Single Bond 2 Adhesive, 3M ESPE, St. Paul, MN, EUA). No centro do disco de cer?mica, foi confeccionado um bloco em resina composta microh?brida (Charisma, Heraeus kulzer, Hanau, Alemanha). Cada grupo foi mantido a 100% de umidade a 37?C por uma e quatro semanas na estufa para cultura. Para os ensaios de resist?ncia ao cisalhamento foi utilizada a M?quina de Ensaio Universal modelo DL 2000 (EMIC, S?o Jos? dos Pinhais, PR, Brasil). Os dados obtidos foram analisados estatisticamente com auxilio do SPSS 17.0 e an?lise de vari?ncia com medidas repetidas seguida do teste de Bonferroni. O jateamento com ?xido de alum?nio apresentou os maiores valores ? resist?ncia ao cisalhamento na interface entre a resina composta e a cer?mica EX3; e o mesmo ocorreu na cer?mica Cerabien; por?m a cer?mica EX3 com o tempo de armazenagem de 1 semana e a cer?mica Cerabien com o tempo de armazenagem de 4 semanas. O jateamento com ?xido de alum?nio foi o tratamento superficial que apresentou melhores resultados nos dois tipos de cer?micas de cobertura pesquisadas. O tempo de armazenagem de 4 semanas n?o teve influ?ncia significativa neste estudo.
7

Compara??o da resist?ncia de uni?o ? microtra??o de sistemas cer?micos odontol?gicos bilaminares

Fracasso, Lisiane Martins 13 January 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:31Z (GMT). No. of bitstreams: 1 454706.pdf: 713974 bytes, checksum: b4c4d030b32ac428abd2ac68d41fed1c (MD5) Previous issue date: 2014-01-13 / The introduction of ceramics in dentistry occurred since the eighteenth century through the use in complete denture. Bilayered systems composed by metal and ceramic emerged from the 60s and the interest in ceramic systems composed by a ceramic infrastructure that provides resistance associated with an aesthetic cover ceramic becomes evident in the last decades of the past century. Thus, different types of ceramics were inserted in the dental commerce. The aim of this study was to evaluate the microtensile bond strength of three systems of all-ceramics: E- max Press, In-Ceram Zirconia and Mark II with its respectively veneering porcelain. Samples were prepared by using a conformer of ceramic samples and included in the center of a ring of polyvinyl chloride (PVC). Three samples of each system were cut into microbars of a square millimeter in cross section. Five specimens of each sample were randomly selected for the microtensile bon strength test (n = 14). An Universal Testing Machine with 0,5mm/min was used for the microtensile bond strength test. Data were statistically analyzed using the G * Power 3.1.7 software. The distribution of normality was analyzed using the Shapiro-Wilk test (E- max Press, p = 0,96; In-Ceram Zirconia, p = 0,25, Mark II, p = 0,56). There were no homogeneity between samples when was used Levene test (p = 0,01). For this reason, the data were submitted to analysis of variance test followed by multiple comparison Games-Howell test. There was statistically significant difference between groups (p = 0,01), and E-max Press (17,88a ? 5,92 MPa) showed higher resistance to the other groups, followed by Mark II (12,98b ? 4,21 MPa) and In-Ceram Zirconia (9.44c ? 2.25 MPa). Therefore, there is a significant difference between the union of infrastructure and coverage in the different systems, which may influence longevity of these restorations. / A introdu??o das cer?micas na odontologia ocorreu a partir do s?culo XVIII atrav?s da utiliza??o das mesmas em pr?tese total. Sistemas bilaminares compostos por metal e cer?mica surgiram a partir da d?cada de 60 e o interesse por sistemas cer?micos bilaminares compostos por uma cer?mica de infra-estrutura que proporciona resist?ncia associada a uma cer?mica de cobertura que oferece est?tica torna-se evidente nas ?ltimas d?cadas do s?culo passado. Assim, diversos tipos de cer?micas foram introduzidas no mercado odontol?gico. O objetivo deste estudo foi avaliar a resist?ncia ? microtra??o de tr?s sistemas de cer?micas puras: E-max Press, In-Ceram Zirc?nia e Mark II com as respectivas cer?micas de cobertura de cada sistema. As amostras foram confeccionadas atrav?s da utiliza??o de um conformador de amostras de cer?micas e inclu?das no centro de um anel de policloreto de vinila (PVC). Tr?s amostras de cada sistema foram cortadas em palitos de um mil?metro quadrado em sua sec??o transversal. Cinco corpos-de-prova de cada amostra foram selecionados aleatoriamente para o teste de microtra??o (n = 14). Para o ensaio de microtra??o foi utilizada uma M?quina de Ensaio Universal com velocidade de 0,5mm/min. Os dados obtidos foram analisados estatisticamente atrav?s do software G* Power 3.1.7. A distribui??o de normalidade foi verificada com o teste Shapiro-Wilk (E-max Press, p = 0,96; In-Ceram Zirc?nia, p = 0,25; Mark II, p = 0,56). N?o foi verificada homogeneidade entre as amostras atrav?s do teste de Levene (p = 0,01). Portanto, os dados foram submetidos ao teste de An?lise de Vari?ncia seguido de teste de Compara??es M?ltiplas Games-Howell. Foi registrada diferen?a estatisticamente significativa entre os grupos (p = 0,01), sendo que E-max Press (17,88a ? 5,92 MPa) apresentou resist?ncia a microtra??o superior aos demais grupos, seguido de Mark II (12,98b ? 4,21 MPa) e In-Ceram Zirc?nia (9,44c ? 2,25 MPa). Portanto, verifica-se uma diferen?a significativa entre a uni?o das cer?micas de infra-estrutura e cobertura nos diferentes sistemas, o que poder? influenciar na longevidade cl?nica destas restaura??es.
8

Estudo de concretos de diferentes resist?ncias ? compress?o submetidos a altas temperaturas sem e com incorpora??o de fibras de politereftalato de etileno (PET) / Study of different resistance of concrete when applied to high temperatures no and with addition fiber polyethylene terephthalate (PET)

Silva, Janaina Salustio da 22 April 2013 (has links)
Made available in DSpace on 2014-12-17T14:48:14Z (GMT). No. of bitstreams: 1 JanainaSS_DISSERT.pdf: 4645317 bytes, checksum: 1f500f6eaf05e8ac34d38ba500240ab2 (MD5) Previous issue date: 2013-04-22 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The reinforced concrete structures are largely used in buildings worldwide. Upon the occurrence of fire in buildings, there is a consensus among researchers that the concrete has a high resistance to fire, due mainly to its low thermal conductivity. However, this does not mean that this material is not affected by exposure to high temperatures. Reduction of the compressive strength, modulus of elasticity, discoloration and cracking, are some of the effects caused by thermal exposure. In the case of concretes with higher resistance occurs even desplacamentos explosives, exposing the reinforcement to fire and contributing to reducing the support capacity of the structural element. Considering the above, this study aims to examine how the compressive strength and porosity of concrete are affected when subjected to high temperatures. Were evaluated concrete of different resistances, and even was the verified if addition fibers of polyethylene terephthalate (PET) in concrete can be used as an alternative to preventing spalling. The results indicated that explosive spalling affect not only high strength concrete whose values of this study ranged from 70 to 88 MPa, as well as conventional concrete of medium strength (52 MPa) and the temperature range to which the concrete begins to suffer significant changes in their resistance is between 400 ? C and 600 ? C, showing to 600 ? C a porosity up to 188% greater than the room temperature / As estruturas de concreto armado s?o largamente utilizadas nas edifica??es em todo o mundo. Quando da ocorr?ncia de inc?ndio em edifica??es, ? consenso entre os estudiosos, que o concreto apresenta uma elevada resist?ncia ao fogo, devido principalmente a sua baixa condutividade t?rmica. No entanto, isto n?o significa que esse material n?o seja afetado pela exposi??o a elevadas temperaturas. Redu??o de resist?ncia ? compress?o e no m?dulo de elasticidade, altera??o na colora??o e aparecimento de fissuras, s?o alguns dos efeitos causados pela exposi??o t?rmica. No caso de concretos com resist?ncia mais elevada, ocorre ainda desplacamentos explosivos, expondo as armaduras ao fogo, e contribuindo assim para a redu??o da capacidade suporte do elemento estrutural. Diante do exposto, o presente trabalho tem por objetivo analisar como a resist?ncia ? compress?o e a porosidade do concreto s?o afetadas quando submetido a elevadas temperaturas. Foram avaliados concretos de diferentes resist?ncias, e ainda foi verificado se a incorpora??o de fibras de politereftalato de etileno (PET), em matriz de concreto, pode ser usada como alternativa a preven??o do lascamento. Os resultados indicaram que lascamentos explosivos acometem n?o somente os concretos de alta resist?ncia, cujos valores desta pesquisa variaram de 70 a 88 MPa, como tamb?m o concreto convencional de m?dia resist?ncia (52 MPa), e que a faixa de temperatura para o qual o concreto come?a a sofrer altera??es expressivas em sua resist?ncia fica entre 400 ?C e 600 ?C, apresentando aos 600 ?C uma porosidade at? 188% maior que a apresentada a temperatura ambiente
9

Frequ?ncia e significado cl?nico da express?o da glicoprote?na P e da prote?na relacionada a resist?ncia a m?ltiplas drogas na leucemia miel?ide aguda

Cunha, Andr?a Luciana Ara?jo da 30 August 2013 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-01-04T19:56:36Z No. of bitstreams: 1 AndreaLucianaAraujoDaCunha_TESE.pdf: 62271689 bytes, checksum: f3e505d6758068c74606405cf05b2b9c (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-01-05T19:52:34Z (GMT) No. of bitstreams: 1 AndreaLucianaAraujoDaCunha_TESE.pdf: 62271689 bytes, checksum: f3e505d6758068c74606405cf05b2b9c (MD5) / Made available in DSpace on 2016-01-05T19:52:34Z (GMT). No. of bitstreams: 1 AndreaLucianaAraujoDaCunha_TESE.pdf: 62271689 bytes, checksum: f3e505d6758068c74606405cf05b2b9c (MD5) Previous issue date: 2013-08-30 / Despite the advances in the cure rate for acute myeloid leukemia, a considerable number of patients die from their disease due to the occurrence of multidrug resistance (MDR). Overexpression of the transporter proteins P-glycoprotein (Pgp) and multidrug resistance-associated protein (MRP) confer resistance to the treatment these leukemias. OBJECTIVE: To analyze the expression of the Gpp and MRP1 in patients with AML by flow cytometry (FC) and to determine the correlation between expression and demographic and also clinical and laboratorial variables. METHODS: Bone marrow and peripheral blood samples from 346 patients with a diagnosis of AML were assessed for the expression of Pgp and MRP1 by FC. RESULTS: The expression of Pgp and MRP1 was found in 111 (32.1%) and 133 (38.4%) patients, respectively, with greater prevalence in older patients and lower in adolescents, observing also a high incidence in patients with refractory disease, recurrence and secondary in comparison with the cases of de novo AML. Regarding the laboratory findings, we observed a higher correlation statistically significant between the expression of Pgp and MRP1 in AML CD34+ and FAB AML M7, M5A and M2 and lower the M3 subtype, not observed statistically significant correlation between the phenotype MDR and other laboratory data such with hemoglobin, leukocyte count, platelet count, aberrant expression of lymphoid antigens (CD2, CD7 and CD19) and clinical signs related to the disease. CONCLUSIONS: The results showed that the detection of MDR phenotype by flow cytometry can be a molecular marker for prognosis independent patients diagnosed with AML.
10

Influ?ncia da forma??o de pozolanas com adi??o de metacaulim em concreto de alta resist?ncia

Soares, Faisy Paulino Pereira 15 March 2013 (has links)
Made available in DSpace on 2014-12-17T14:58:21Z (GMT). No. of bitstreams: 1 FaisyPPS_DISSERT_Capa_ate _pag30.pdf: 3190627 bytes, checksum: 6b8c39ddf6fc3949b555ea3b2beef8a3 (MD5) Previous issue date: 2013-03-15 / The need to build durable structures and resistant to harsh environments enabled the development of high strength concrete, these activities generate a high cement consumption, which implies factor in CO2 emissions. Often the desired strength is not achieved using only the cement composition. This study aims to evaluate the influence of pozzolans with the addition of metakaolin on the physical mechanics of high strength concrete comparing them with the standard formulation. Assays were performed to characterize the aggregates according to NBR 7211, evaluation of cement and coarse aggregate through the trials of petrography (NBR 15577-3/08) and alkali-aggregate reaction (NBR 15577-05/08). Specimens were fabricated according to NBR 5738-1/04 with additions of 0%, 4%, 6%, 8% and 10% of metakaolin for cement mortars CP V in the formulations. For evaluation of the concrete hardened in fresh state and scattering assays were performed and compressive strength in accordance with the NBR 7223/1992 and NBR 5739-8/94 respectively. The results of the characterization of aggregates showed good characteristics regarding size analysis and petrography, as well as potentially innocuous as the alkali-aggregate reaction. As to the test of resistance to compression, all the formulations with the addition of metakaolin showed higher value at 28 days of disruption compared with the standard formulation. These results present an alternative to reduce CO2 emissions, and improvements in the quality and durability of concrete, because the fine particle size of metakaolin provides an optimal compression of the mass directly influencing the strength and rheology of the dough / A necessidade de construir estruturas dur?veis e resistentes a ambientes agressivos proporcionou o desenvolvimento do concreto de alta resist?ncia, tais atividades geram um alto consumo de cimento, fator que implica na emiss?o CO2. Muitas vezes a resist?ncia desejada n?o ? atingida utilizando apenas o cimento na composi??o. Este trabalho tem como objetivo avaliar a influ?ncia das pozolanas com a adi??o de metacaulim nas caracter?sticas f?sico mec?nicas do concreto de alta resist?ncia comparando-as com a formula??o padr?o. Foram realizados ensaios de caracteriza??o dos agregados de acordo com a norma NBR 7211, avalia??o do cimento e agregado gra?do atrav?s dos ensaios de petrografia (NBR 15577 - 3/08) e rea??o alcali-agregado (NBR 15577-05/08). Foram confeccionados corpos de prova de acordo com a norma NBR 5738-1/04 com adi??es de 0%, 4%, 6%, 8% e 10% de metacaulim em substitui??o ao cimento CP V nas formula??es. Para avalia??o do concreto no estado fresco e endurecido foram realizados ensaios de espalhamento e resist?ncia ? compress?o de acordo com as normas NBR 7223/1992 e NBR 5739-8/94 respectivamente. Os resultados da caracteriza??o dos agregados apresentaram boas caracter?sticas quanto ? an?lise granulom?trica e petrografia, bem como potencialmente in?cuos quanto ? rea??o alcali-agregado. Quanto ao ensaio de resist?ncia ? compress?o, todas as formula??es com adi??o de metacaulim apresentaram valor superior aos 28 dias de ruptura quando comparadas com a formula??o padr?o. Estes resultados apresentam uma alternativa de redu??o da emiss?o de CO2, al?m de melhorias na qualidade e durabilidade do concreto, pois a fina granulometria do metacaulim proporciona uma ?tima compacta??o da massa influenciando diretamente na resist?ncia mec?nica e reologia da massa

Page generated in 0.0398 seconds