• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 1
  • Tagged with
  • 193
  • 193
  • 136
  • 114
  • 87
  • 80
  • 74
  • 71
  • 57
  • 50
  • 50
  • 48
  • 47
  • 45
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avalia??o in vitro da resist?ncia de uni?o ao cisalhamento na colagem de br?quetes por duas fontes de luz

Mezzomo, Claudia Santos 18 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:42Z (GMT). No. of bitstreams: 1 386791.pdf: 7078042 bytes, checksum: 4c1fadb128575046216a3274f924db24 (MD5) Previous issue date: 2007-01-18 / O objetivo do presente estudo foi comparar, in vitro, a resist?ncia de uni?o ao cisalhamento de br?quetes colados quando expostos ? luz LED e ? luz hal?gena (QTH) mediante diferentes tempos de exposi??o. Para isso 126 dentes pr?-molares foram divididos em seis grupos de acordo com a fonte de luz e o tempo de exposi??o utilizado. Para o conjunto LED, foram usados os tempos de 5, 10 e 15s e para o conjunto QTH, 10, 20, e 30s. Os aparelhos fotopolimerizadoes LED (Ortholux LED Curing Light, 3M-Unitek EUA) e QTH (XL 3000, 3M Unitek EUA) tiveram suas intensidades avaliadas inicialmente e, a cada 10 colagens, por radi?metros espec?ficos para cada natureza de luz, obtendo valores m?dios de 581mW/cm? e 420mW/cm?, respectivamente. Ap?s 24h de estocagem em ?gua destilada a 37?C, os corpos - de - prova foram levados ? m?quina de ensaio mec?nico (Emic DL 2000?) e submetidos ? tens?o de cisalhamento, no sentido c?rvico-oclusal, ? velocidade de 1mm/min. De acordo com os testes estat?sticos ANOVA e Tukey, houve diferen?a significativa entre os grupos estudados (p< 0,01). Os grupos fotoativados por LED 5s (17,20MPa) e 10s (20,54MPa) n?o diferiram entre si, mostrando diferen?a estatisticamente significativa quando comparados ao grupo LED 15s (25,24MPa). Quanto ? fonte luminosa QTH, o grupo de 10s (16,97MPa) diferiu dos 20s (23,61MPa) e 30s (21,33MPa), enquanto esses n?o diferiram entre 8 si. A maior m?dia de resist?ncia de uni?o foi observada no grupo LED 15s, embora este grupo n?o tenha se diferenciado estatisticamente dos grupos QTH 20s e 30s. Verificou-se que at? mesmo os grupos que tiveram as menores m?dias de resist?ncia de uni?o, QTH 10s e LED 5s, respectivamente, apresentaram valores compat?veis com o uso cl?nico. Segundo o teste Kruskal-Wallis, houve diferen?a significativa na distribui??o dos resultados do IAR entre os grupos (p< 0,01). O grupo LED 15s demonstrou padr?o de fratura predominantemente ?ndice 0, sendo observado fratura de esmalte em dois corpos - de - prova. Apesar dos grupos LED 5s e QTH 10s apresentarem maior predom?nio de escores 1 e 2, respectivamente, foram nesses que se observou a maior freq??ncia de escores 3, QTH 10s (10,5%) e LED 5s (9,5%). Comportamento oposto foi observado nos grupos LED 10s e 15s, onde n?o foi registrado freq??ncia de ?ndice 3 (0%). Os achados do presente estudo sugerem que a tecnologia LED (Free Light Ortholux, 3M Unitek) pode ser utilizada, na colagem de br?quetes, com tempos de cura menores em rela??o ? luz hal?gena para a resina Transbond XT, sendo que, o tempo m?nimo de 5s com LED apresentou valor de resist?ncia de uni?o clinicamente aceit?vel.
52

Transtorno de d?ficit de aten??o/hiperatividade em crian?as e adolescentes com epilepsias de dif?cil controle : influ?ncia do tratamento com Metilfenidato sobre a qualidade de vida

Radziuk, Ana Lucia Germano da Silva 30 September 2010 (has links)
Made available in DSpace on 2015-04-14T13:35:37Z (GMT). No. of bitstreams: 1 445040.pdf: 2039522 bytes, checksum: 2f433c611b99e5b28cbd56ef7aed5bb1 (MD5) Previous issue date: 2010-09-30 / Rationale: Comorbidity between difficult-to-treat epilepsies and ADHD is high, but because of concerns with the use of stimulants in this population, there is no data on the possible impact of such treatment.Objective: We studied the effect of methylphenidate in the quality of life of children and adolescents with DSM-IV criteria for ADHD and difficult-to-treat epilepsies.Methods: Open label, non-controlled trial, with intention-to-treat analysis following 30 patients for 6 months. Subjects received methylphenidate following 3 months of baseline, during which antiepileptic drugs (AEDs) were adjusted and epilepsy, ADHD and quality of life variables were assessed. Multivariate regression analysis identified the main variables correlated with outcome.Results: Only one patient withdrew because of seizure worsening. Following methylphenidate introduction, reaching doses of 0.40 - 0.50 mg/kg/day, a marked improvement in quality of life scores and a significant reduction in seizure frequency and severity were observed. Female sex, reduction of core ADHD symptom burden and tolerability to adequate doses of methylphenidate correlated with quality of life scores.Conclusion: These preliminary data suggest that methylphenidate treatment is safe and effective to patients with ADHD and difficult-to-treat epilepsies and has a positive impact on quality of life scores / Fundamentos - A associa??o entre epilepsia e TDAH ? altamente prevalente comprometendo a Qualidade de Vida de crian?as e adolescentes com crises epil?pticas. Metilfenidato Ritalina(R) - ? o medicamento de uso consagrado para o Transtorno de D?ficit de Aten??o/Hiperatividade com 80% de efic?cia em crian?as com TDAH com ou sem epilepsia. Questiona-se a possibilidade do MFD diminuir o limiar convulsivo dos pacientes epil?pticos.Objetivos - Avaliar a influ?ncia do uso de Metilfenidato sobre a Qualidade de Vida e o perfil das crises epil?pticas em crian?as e adolescentes com epilepsias de dif?cil controle.Pacientes e M?todos - Foi realizado um ensaio cl?nico aberto, n?o randomizado, com 30 crian?as e adolescentes do Ambulat?rio de Neuro-Epilepsias Graves apresentando crises de dif?cil controle e TDAH. Foram avaliadas quanto ? Qualidade de Vida, sintomas de TDAH e perfil das crises antes e ap?s o uso de MFD. Houve um ajuste/troca de FAE somente no tempo -3 (baseline). Metilfenidato foi iniciado ap?s estes 3 meses (T 0) sem outras modifica??es nos FAE com avalia??es 1 m?s e 3 meses ap?s. Foram avaliados tamb?m eventos adversos ao uso do MFD.Resultados - Ocorreu melhora da QV em todos os momentos avaliados: T -3 (baseline) a T0, T0 a T+1 e T+1 a T+3. A melhora ocorrida entre T-3 e T0, momento em que foi realizado o ajuste de FAE, n?o foi estatisticamente significativa. Nos tempos subseq?entes, com o uso de MFD, as varia??es de QV ocorridas apresentaram signific?ncia estat?stica. Ocorreu melhora da qualidade de vida com signific?ncia estat?stica em indiv?duos do sexo feminino, os que apresentaram in?cio mais tardio da doen?a e naqueles em houve maior diminui??o dos escores de d?ficit de aten??o. Os pacientes com crises generalizadas apresentaram piores ?ndices de QV. N?o houve associa??o estatisticamente significativa entre a varia??o da QV com a freq??ncia e/ou gravidade das crises, idade, dura??o da doen?a, QI, ocorr?ncia de eventos adversos.Conclus?es - Houve melhora da QV de pacientes epil?pticos de dif?cil controle tratados com MFD sem que houvesse piora na freq??ncia ou gravidade das crises. Condizente com a literatura tamb?m n?o verificamos a presen?a de efeitos colaterais de gravidade significativa ao MFD. Estes dados preliminares sugerem a possibilidade da utiliza??o deste f?rmaco no tratamento de crian?as e adolescentes com crises epil?pticas de dif?cil controle com a conseq?ente melhora de QV destes pacientes.
53

Estudo experimental para avalia??o da resist?ncia ? compress?o entre dois modelos de fixa??o da osteotomia em L do f?mur proximal

Urnauer, Luciano 22 July 2013 (has links)
Made available in DSpace on 2015-04-14T13:35:50Z (GMT). No. of bitstreams: 1 452619.pdf: 1154303 bytes, checksum: 1c5fd674a322085ab06b90525da4401a (MD5) Previous issue date: 2013-07-22 / Introduction: Coxa brevis is a deformity of the proximal femur caused by a decrease or absence of growth of the physis of the proximal femur, usually caused by avascular necrosis present condition in conditions such as developmental dysplasia of the hip, proximal femoral epiphysiolysis, septic arthritis or disease Legg-Calv?-Perthes disease. Several surgeries have been proposed to lower the greater trochanter and femoral neck lengthening reestablishing the anatomy. Objective: To compare the mechanical tests by polyurethane in bone models the compressive strength of two different assemblies of plates for fixing osteotomy "L" of the proximal femur. Material and Methods: We used anatomical models of the proximal femur polyurethane which underwent an osteotomy longitudinal and divided into two groups with one group fixed with 4.5 DCP plate 10 holes with four screws proximal and three distal screws and fixed with a group 4.5 DCP plate 6 holes with two proximal and two distal screws. The anatomical models were tested for flexo in mechanical universal testing machine and was evaluated relative stiffness and linear movement. Results: By comparing the two groups in flexo tests, the average value of the relative stiffness in group 1 set with the long plate was 386.17 x10-3 N / m. In the group with the smaller plate fixed average value of the relative stiffness was 261,89 x10-3 N / m. The average linear displacement observed for an applied force of 1000 N in group 1 was 2.53 x10-3. In group 2, the mean value of linear displacement was 3.49 x 10-3m. Conclusion: Based on the parameters measured in the tests flexo, stability obtained by fixing the first group with a plate of ten holes was significantly higher than that obtained by fixing the second group with six holes of the plate. / Introdu??o: Coxa brevis ? uma deformidade do f?mur proximal causada pela diminui??o ou aus?ncia de crescimento da fise da extremidade proximal do f?mur, geralmente causada por necrose avascular condi??o presente nas patologias como displasia do desenvolvimento do quadril, epifisi?lise femoral proximal, artrite s?ptica ou doen?a de Legg-Calv?-Perthes. Diversas cirurgias tem sido propostas para rebaixar o grande troc?nter ou alongar o colo femoral reestabelecendo a anatomia. Objetivo: comparar atrav?s de testes mec?nicos em modelos ?sseos de poliuretano a resist?ncia ? compress?o entre duas montagens diferentes de placas para fixa??o osteotomia em L do f?mur proximal. Material e M?todos: Foram utilizados modelos anat?micos de f?mur proximal em poliuretano no qual foi realizado uma osteotomia longitudinal e divididos em dois grupos sendo um grupo fixado com placa 4,5 DCP 10 furos com quatro parafusos proximais e tr?s parafusos distais e um grupo fixado com placa 4,5 DCP 6 furos com dois parafusos proximais e dois distais. O modelos anat?micos foram submetidos a teste de flexocompress?o em m?quina universal de ensaios mec?nicos e foi avaliado a rigidez relativa e o deslocamento linear. Resultados: Ao comparar os dois grupos nos ensaios de flexocompress?o, o valor m?dio da rigidez relativa no grupo 1 fixado com a placa longa foi de 386,17 x10-3 N/m. No grupo fixado com a placa menor o valor m?dio da rigidez relativa foi de 261,89 x10-3 N/m. O valor m?dio do deslocamento linear, observado para uma for?a aplicada de 1000 N, no grupo 1 foi de 2,53 x10-3. No grupo 2 o valor m?dio do deslocamento linear foi de 3,49 x10-3m. Conclus?o: Com base nos par?metros analisados nos ensaios de flexocompress?o, a estabilidade obtida pela fixa??o do grupo 1 com placa de dez furos foi significativamente maior que a obtida pela fixa??o no grupo 2 com a placa de seis furos.
54

Avalia??o da resist?ncia de uni?o de adesivos universais ? dentina

Costa, Daniele Morosini 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-06-30T17:18:27Z No. of bitstreams: 1 DIS_DANIELE_MOROSINI_COSTA_PARCIAL.pdf: 515880 bytes, checksum: 055ee81e963cb874c2263912d41a40f6 (MD5) / Made available in DSpace on 2016-06-30T17:18:27Z (GMT). No. of bitstreams: 1 DIS_DANIELE_MOROSINI_COSTA_PARCIAL.pdf: 515880 bytes, checksum: 055ee81e963cb874c2263912d41a40f6 (MD5) Previous issue date: 2016-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The aim of this study was to evaluate, in vitro, the tensile bond strength to dentin of the adhesive systems Single Bond Universal (3M), All-Bond Universal (Bisco) and One Coat 7 (Colt?ne), in the self-etch mode, taking Clearfil SE Bond as control. The middle portion of 120 bovine teeth were included in a selfcured acrylic resin and abraded in a mechanic lathe with water refrigeration in order to obtain a plane surface in dentin. The adhesives systems were applied on the dentin in accordance with the instructions of the manufacturers, followed by the application of composite resin Z250 (3M). Thirty specimens were obtained for each adhesive system. After immersion in distilled water at 37 oC for 24 hours, half of the specimens were submitted to cyclic loading using 500,000 cycles. For all specimens, the tensile bond strength was determinated in a universal testing machine (EMIC DL-2000) at a cross-head speed of 0.5 mm/minute. The results were analyzed by two-way ANOVA and Tukey?s test (? = 5%). The interaction between the factors adhesive system and cyclic loading was significant (p<0.05). The means followed by the same letter represent no statistical difference for the tensile bond strength (MPa) after 24 h: One Coat 7 = 7.86A (?2.90), Single Bond Universal = 6.78AB (?2.03), All-Bond Universal = 5.61BC (?2.32), Clearfil SE Bond = 3.53C (?1.89). After cyclic loading, the adhesive systems Clearfil SE Bond, Single Bond Universal and All-Bond Universal maintained the bond strength values comparable to 24 h period. There was a significant decrease only for One Coat 7. The adhesive system Single Bond Universal, All-Bond Universal and One Coat 7, in the self-etch mode, had bond strength to dentin comparable to Clearfil SE Bond. Only the adhesive system One Coat 7 decreased the bond strength to dentin after cyclic loading. / O objetivo deste trabalho foi avaliar, in vitro, a resist?ncia de uni?o ? tra??o sobre a dentina dos sistemas adesivos universais Single Bond Universal (3M), All-Bond Universal (Bisco) e One Coat 7 (Colt?ne), na vers?o autocondicionante, tendo o Clearfil SE Bond como controle. O ter?o m?dio da coroa de 120 dentes incisivos bovinos foi inclu?do em resina acr?lica autopolimeriz?vel e desgastado em um torno mec?nico sob refrigera??o ? ?gua para obter uma superf?cie plana em dentina. Os sistemas adesivos foram aplicados sobre a dentina de acordo com as instru??es dos fabricantes, seguido da aplica??o de resina composta Z250 (3M). Trinta corpos de prova foram confeccionados para cada sistema adesivo. Ap?s armazenagem em ?gua destilada a 37? C por 24 h, metade dos corpos de prova de cada grupo foi submetida ? 500.000 ciclos de ciclagem mec?nica. Todos os corpos de prova foram submetidos ao teste de resist?ncia de uni?o ? tra??o na m?quina de ensaio universal EMIC DL-2000 com velocidade de 0,5 mm/minuto. Os resultados foram analisados pela ANOVA de duas vias e o teste de Tukey (? =5%). Houve intera??o entre os fatores sistema adesivo e ciclagem mec?nica (p<0,05). As m?dias seguidas de mesma letra n?o diferem estatisticamente para a resist?ncia de uni?o (MPa) medida ap?s 24 h: One Coat 7 = 7,86? (?2,90), Single Bond Universal = 6,78AB (?2,03), All-Bond Universal = 5,61BC (?2,32), Clearfil SE Bond = 3,53C (?1,89). Ap?s ciclagem mec?nica, os sistemas adesivos Clearfil SE Bond, Single Bond Universal e All-Bond Universal mantiveram os valores de resist?ncia de uni?o compar?veis ao per?odo de 24 h, havendo redu??o significativa para o One Coat 7. Os sistemas adesivos Single Bond Universal, All-Bond Universal e One Coat 7, na vers?o autocondicionante, tiveram resist?ncia de uni?o ? dentina compar?vel ao sistema adesivo Clearfil SE Bond. Apenas o sistema adesivo One Coat 7 apresentou redu??o na resist?ncia de uni?o ? dentina ap?s ciclagem mec?nica.
55

Efeito da usinagem e de procedimentos p?s-usinagem na superf?cie de materiais odontol?gicos para CAD/CAM

Nunes, Laura Smidt 08 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-07-14T16:57:14Z No. of bitstreams: 1 DIS_LAURA_SMIDT_NUNES_PARCIAL.pdf: 228259 bytes, checksum: 74df0dbd4064a00e8b0071f07e6d7ecf (MD5) / Made available in DSpace on 2016-07-14T16:57:14Z (GMT). No. of bitstreams: 1 DIS_LAURA_SMIDT_NUNES_PARCIAL.pdf: 228259 bytes, checksum: 74df0dbd4064a00e8b0071f07e6d7ecf (MD5) Previous issue date: 2016-03-08 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The aim of the study was to evaluate the surface roughness and analyze the surface topography of five different ceramics, a resin composite and two polymers for CAD/CAM after milling and post milling procedures. Blocks of Mark II, IPS Empress CAD, IPS e.max CAD, Enamic, Lava Ultimate, Suprinity, CAD-Temp and CAD-Waxx were milled in CEREC MCXL system. The surface roughness (Ra; ?m) was measured before and after millig procedures, polishing and glaze (when indicated) followed by analysis by SEM and AFM. The results were subjected to statistical tests (one-way ANOVA for repeated measures and Tukey HSD and one-way ANOVA also with Post-Hoc Tukey, respectively) with a significance level of 5% (?=0.05). The milling step significantly increased surface roughness in all tested materials (p<0.05). Mechanical polishing was able to reduce the roughness generated by grinding, requiring the glazing step only in partially crystallized ceramic (IPS e.max CAD and Suprinity). In other materials (Mark II, IPS Empress CAD, Lava Ultimate, Enamic, CAD- Temp and CAD-Waxx) mechanical polishing was enough to achieve similar surface roughness values of the smoothness of the blocks directly from manufacturers. The study suggests that the glaze step can be suppressed in materials completely crystallized and/or polymerized by the manufacturer, these having no statistically significant difference when it's just done mechanical polishing. / O objetivo do estudo foi avaliar a rugosidade superficial e analisar a topografia de superf?cie de cinco diferentes cer?micas, um comp?sito resinoso e dois acr?licos para CAD/CAM ap?s usinagem e procedimentos p?s-usinagem. Blocos de Mark II, IPS Empress CAD, IPS e.max CAD, Enamic, Lava Ultimate, Suprinity, CAD-Temp e CAD- Waxx foram usinados no sistema CEREC MCXL. A rugosidade superficial (Ra; ?m) foi aferida antes e ap?s os procedimentos de usinagem, polimento e glaze (quando indicado) seguidos de an?lises em MEV e MFA. Os resultados foram submetidos a testes estat?sticos (teste one-way ANOVA para medidas repetidas e Tukey HSD e ANOVA one-way tamb?m com Post-Hoc Tukey, respectivamente) com n?vel de signific?ncia de 5% (?=0,05). A etapa de fresagem aumentou significativamente a rugosidade superficial em todos os materiais testados (p<0,05). O polimento foi capaz de reduzir a rugosidade gerada pela usinagem, sendo necess?ria a etapa de glazeamento apenas para cer?micas parcialmente cristalizadas (IPS e.max CAD e Suprinity). Nos demais materiais (Mark II, IPS Empress CAD, Lava Ultimate, Enamic, CAD-Temp e CAD-Waxx) o polimento mec?nico foi suficiente para atingir valores de rugosidade superficial similares a lisura dos blocos provenientes diretamente dos fabricantes. O estudo sugere que a etapa de glaze pode ser suprimida nos materiais j? provenientes do fabricante completamente cristalizados e/ou polimerizados, nestes n?o possuindo diferen?a estatisticamente significativa quando apenas ? realizado polimento mec?nico.
56

Influ?ncia do tempo de condicionamento e concentra??o do ?cido fluor?drico na resist?ncia de uni?o de um sistema adesivo ? superf?cie de cer?micas para CAD/CAM

Costa, Helo?sa 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-08-01T16:58:26Z No. of bitstreams: 1 DIS_HELOISA_COSTA_PARCIAL.pdf: 121948 bytes, checksum: b60caab299692040c6bbd09f4274ab38 (MD5) / Made available in DSpace on 2016-08-01T16:58:26Z (GMT). No. of bitstreams: 1 DIS_HELOISA_COSTA_PARCIAL.pdf: 121948 bytes, checksum: b60caab299692040c6bbd09f4274ab38 (MD5) Previous issue date: 2016-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Aims: to evaluate the microtensile bond strength of an adhesive (Signum Ceramic Bond (Heraeus / Kulzer) made for repairing fractured CAD/CAM ceramics after different surface treatments. Materials and Methods: Three different types of ceramic blocks for CAD / CAM were used: Mark II, Empress CAD and e.max CAD. The ceramics were divided into four subgroups according to the following surface treatment: G1: roughening with specific drill (ASP, Signum) + adhesive system; G2: hydrofluoric acid (HF) 5% + Signum, G3: ASP + 5% + AF Signum, G4: ASP + AF 10% + Signum. After the adhesive system application, a 6.0 mm resin composite block (Charisma) was made for the microtensile test. After 15 days of storage in distilled water, the blocks were cut and selected 20 sticks with cross sectional area of 1.0 mm2. The specimens were submitted to microtensile in a universal testing machine. Results: The use of ASP + AF 10% promoted the highest bond strength values in the ceramic Mark II (23.08 MPa) and Empress CAD (29.36 MPa). In e.max CAD, the use of ASP + AF 5% led to the highest values of bond strength (25.19 MPa). Based on these results we conclude that the adhesion of the adhesive system Signum for ceramics repairing depends on surface treatment being the association abrasion + hydrofluoric acid the most suitable. / Objetivos: Esse estudo teve por objetivo avaliar, in vitro, a influ?ncia do tratamento de superf?cie de cer?micas para CAD/CAM na resist?ncia de uni?o do adesivo Signum Ceramic Bond (Heraeus/Kulzer) utilizado para reparo de cer?micas fraturadas. Materiais e M?todos: tr?s diferentes tipos de blocos de cer?mica para CAD/CAM foram utilizados: Mark II, Empress CAD e e.Max CAD. As cer?micas foram divididas em 4 subgrupos de acordo com o tratamento de superf?cie empregado: G1: asperiza??o com broca espec?fica (ASP, Signum) + sistema adesivo; G2: ?cido fluor?drico (AF) 5% + Signum, G3: ASP + AF 5% + Signum, G4: ASP + AF 10% + Signum. Ap?s a aplica??o do sistema adesivo, um bloco de resina composta (Charisma) foi confeccionado para o ensaio de microtra??o. Ap?s 15 dias de armazenamento em ?gua destilada, os blocos foram seccionados e selecionados 20 palitos com ?rea adesiva de aproximadamente 1,0 mm2. Os corpos de prova foram submetidos ao ensaio de microtra??o em uma m?quina de ensaios universal. Resultados: O uso da ASP + AF 10% promoveu os maiores valores de resist?ncia adesiva nas cer?micas Mark II (23,08 MPa) e Empress CAD (29,36 MPa). No e.max CAD, o uso da ASP + AF 5% propiciou os maiores valores de resist?ncia adesiva (25,19 MPa). Com base nos resultados encontrados ? poss?vel concluir que a ades?o do sistema adesivo Signum para reparo de cer?micas para CAD/CAM depende do tratamento de superf?cie empregado sendo que a associa??o abras?o + ?cido fluor?drico ? a mais indicada.
57

Influ?ncia do c?lcio na corros?o do a?o SAE 1045 temperado e revenido em solu??es ricas em CO2 em alta press?o e alta temperatura / The influence of calcium on the corrosion of SAE 1045 steel tempered and quenched in CO2-rich solutions at high pressure and high temperature

Oliveira, Loani Bassani de 30 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-08-03T18:24:29Z No. of bitstreams: 1 DIS_LOANI_BASSANI_DE_OLIVEIRA_COMPLETO.pdf: 4322519 bytes, checksum: e01558dfcb88bb2ce1765983c4cd249e (MD5) / Made available in DSpace on 2016-08-03T18:24:29Z (GMT). No. of bitstreams: 1 DIS_LOANI_BASSANI_DE_OLIVEIRA_COMPLETO.pdf: 4322519 bytes, checksum: e01558dfcb88bb2ce1765983c4cd249e (MD5) Previous issue date: 2016-03-30 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The present study analyzes the influence of the presence of Ca2+, by the addition of CaCO3 in water saturated with CO2, on the corrosion of SAE 1045 steel tempered and quenched under conditions of 80? C, 15 MPa and 168 hours (7 days) andon the properties of the corrosion scales formed on the steel surface. The corrosion rates of the steel were determined by weight loss tests according to ASTM G1-03 (2010). The techniques of electron scanning microscopy by field emission (FEG/MEV), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and potentiodynamic polarization were used to obtain information about the properties of corrosion scales. Uniform corrosion was observed and the results indicated that by adding calcium carbonate, with concentrations of 10 ppm, 100 ppm, 1000 ppm and 10000 ppm of Ca2+ in solution, the corrosion rates by weight loss and the thicknesses of the corrosion product films decreased. However, the addition of calcium carbonate decreased the corrosion rate for all concentrations, probably due to its property of increasing the pH of the solution. The highest corrosion rate determined by weight loss was observed when corrosion was induced without the presence of calcium carbonate and with concentration of 100 ppm of Ca2+. The corrosion rate did not changed linearly with Ca+ concentrations, the highest corrosion rate was observed for 100 ppm of Ca2+. The EDS analyzes provide information that a mixed carbonate is formed in presence of Ca+2 in solution, probably FexCa1-xCO3, with increasing of Ca incorporation in the crystalline lattice of FeCO3, with increasing of calcium content and a respective reduction of Fe amounts. The XRD analyzes also indicated that the corrosion product films formed in the presence of calcium are composed by FeCO3 enriched with Ca besides oxides and iron hydroxides as goethite - FeO(OH) and Fe3O4 - magnetite. Based on the electrochemical tests, the film that had the more negative potential (Ecorr) and higher corrosion current density (icorr) was the one formed in the presence of 100 ppm Ca2+, and this film showed electrochemical properties very similar to the bare steel. / O presente trabalho analisa a influ?ncia da presen?a de Ca2+, por meio da adi??o de CaCO3 em ?gua saturada com CO2, na corros?o do a?o SAE 1045, temperado e revenido, sob condi??es de 80 ?C, 15 MPa e 168 horas (7 dias) e nas propriedades dos filmes de produtos de corros?o formados na superf?cie do a?o. As taxas de corros?o do a?o foram determinadas por testes de perda de massa segundo ASTM G1-03 (2010). As t?cnicas de microscopia eletr?nica de varredura por emiss?o de campo (FEG/MEV), espectroscopia de energia dispersiva (EDS), difra??o de raios X (DRX) e polariza??o potenciodin?mica foram utilizadas para obter informa??es sobre as propriedades dos filmes de produtos de corros?o. Observou-se corros?o uniforme e os resultados mostraram que ao adicionar carbonato de c?lcio, com concentra??es de 10 ppm, 100 ppm, 1000 ppm e 10000 ppm de Ca2+ na solu??o, as taxas de corros?o por perda de massa e as espessuras dos filmes de produtos de corros?o diminuiram. A adi??o de carbonato de c?lcio reduziu as taxas de corros?o para todas as concentra??es de Ca2+, provavelmente, devido sua propriedade de aumentar o pH da solu??o. A taxa de corros?o n?o variou linearmente com a concentra??o de Ca2+ em solu??o, sendo que a maior taxa de corros?o foi observada para a concentra??o de 100 ppm de Ca2+.As an?lises de EDS indicaram a forma??o de carbonato misto, provavelmente FexCa1-xCO3, com o aumento da incorpara??o de Ca na rede cristalina do FeCO3, visto que com o aumento da adi??o de carbonato de c?lcio observou-se um aumento no teor de Ca e uma respectiva redu??o nos teores de Fe. As an?lises de DRX indicaram que os filmes de produtos de corros?o formados em presen?a de c?lcio s?o compostos de FeCO3 enriquecido com Ca, de ?xidos e hidr?xidos de ferro como goetita - FeO(OH) e Fe3O4 - magnetita. De acordo com os ensaios eletroqu?micos, o filme que apresentou o potencial de corros?o menos nobre (Ecorr) e maior densidade de corrente de corros?o (icorr) foi o formado na presen?a de 100 ppm Ca2+, sendo que este filme apresentou propriedades eletroqu?micas muito similares ao do a?o refer?ncia (sem produto de corros?o na superf?cie).
58

Resist?ncia de uni?o ao cisalhamento entre tubos ortod?nticos e miniplacas de ancoragem esquel?tica colados com diferentes materiais

Meirelles, Lucas da Silva 27 January 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-09-26T11:23:37Z No. of bitstreams: 1 DIS_LUCAS_DA_SILVA_MEIRELLES_PARCIAL.pdf: 243991 bytes, checksum: d72682f62c8b046220c35b86e91ffff1 (MD5) / Made available in DSpace on 2016-09-26T11:23:38Z (GMT). No. of bitstreams: 1 DIS_LUCAS_DA_SILVA_MEIRELLES_PARCIAL.pdf: 243991 bytes, checksum: d72682f62c8b046220c35b86e91ffff1 (MD5) Previous issue date: 2016-01-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Most anchorage miniplates that are currently used do not present orthodontic devices. Thus, orthodontists resort to creativity and utilize adaptations such as buttons, brackets or tubes bonded directly to miniplates, which makes them more versatile in terms of dental movement possibilities. The goal of this paper was to determine, in Megapascals (MPa), the strength that can be attributed to the bond between an anchorage miniplate and an orthodontic accessory united by different materials. The bond between the accessory and the miniplates was divided into two groups: Group 1 resin (Transbond XT?, 3M ESPE), 20 specimens; Group 2 Cyanoacrylate (Scoth Bond?, 3M ESPE), 20 specimens. The shearing strength test (Rcp) was performed on a universal testing machine EMIC DL-2000. The result was 2.28 ? 0.44 MPa for Group 1 and 4.90 ? 0.76 MPa for Group 2. Sample normality was verified through the Kolmogorov-Smirnov test. The comparison between the means for the variable response was carried out using the Student T test. There was a significant statistical difference between the groups; however, both materials showed higher strength than that needed for dental movement. / A maioria das miniplacas de ancoragem utilizadas atualmente, n?o apresentam dispositivos ortod?nticos. Dessa forma, ortodontistas lan?am m?o da criatividade e utilizam adapta??es como a colagem de bot?es, br?quetes ou tubos diretamente nas miniplacas, tornando-as mais vers?teis em termos de possibilidades de movimenta??es dent?rias. O objetivo do trabalho foi determinar, em Mega Pascal (MPa), a for?a que pode ser atribu?da a essa uni?o entre a miniplaca de ancoragem e o acess?rio ortod?ntico unidos por diferentes materiais. A uni?o do acess?rio ?s miniplacas, foi dividida em dois grupos: Grupo 1 resina (Transbond XT?, 3M ESPE ), 20 corpo de prova; Grupo 2 Cianoacrilato ( Scoth Bond?, 3M ESPE), 20 corpos de prova. O teste de resist?ncia ao cisalhamento (Rcp) foi realizado na m?quina de ensaio universal EMIC DL-2000. O resultado obtido foi de 2,28 ? 0,44 MP para o Grupo 1 e 4,90 ? 0,76 MPa para o Grupo 2. A normalidade da amostra foi verificada atrav?s do teste Kolmogorov-Smirnov. A compara??o entre as m?dias da vari?vel-resposta foi realizada atrav?s do Teste T de Student. Houve diferen?a estat?stica significante entre os grupos, por?m ambos materiais apresentaram for?a superior a necess?ria para movimenta??o dent?ria.
59

Avalia??o da sensibilidade ? insulina em equinos de uso militar. / Evaluation of insulin sensitivity in horses feeding diet with high level of soluble carbohydrates.

T?rner, Silvia Paranhos 03 March 2009 (has links)
Made available in DSpace on 2016-04-28T14:59:49Z (GMT). No. of bitstreams: 1 SilVia Paranhos Turner.pdf: 1472322 bytes, checksum: 4103df96d4e3b8e5e15b1066a63561ea (MD5) Previous issue date: 2009-03-03 / The study was carried out to evaluate insulin sensitivity in orses fed diets with high level of soluble carbohydrates. The study was undertaken at the 2nd Cavalary and Guard Regiment Andrade Neves Regiment, situated in Rio de Janeiro, in the year of 2007. Blood samples were taken monthly from fasting horses, and body condition scores (BCS) evaluated during nine consecutive months, from February to October, 2007. Blood was sampled into heparinized and fluorized vacutainer tubes and centrifuged, plasma separated, refrigerated and transported to the EQUILAB Laboratory at the Federal Rural University of Rio de Janeiro, where plasma was stores at -20oC. Plasma was analyzed for glucose spectrophotometrically, and insulin by radioimmunoassay. Basal proxies were calculated for the assessment of insulin sensitivity (RSQUI) and pancreatic beta cell response (MIRG). Feed and hay samples were taken monthly and analyzed for nutrient contend. A glycemic index test was undertaken in a selected group of six horses from the sampled group. No significant relation was found between colic incidence and sex, plasma glucose, insulin, MIRG and RSQUI. Animals that had colic had a trend (P = 0.072) to have a higher BCS, compared to animals without colic during the analyzed period. Horses that had colic had lower body weights than horses without colic (P < 0.05), suggesting that these animals also had lower lean mass, and perhaps more fat. Insulin sensitivity (RSQUI) was higher in the months of higher physical activity. Results of the current study indicate that physical activity is the best prevention for insulin resistance, and, at the same time helps to reduce body fat, and indirectly prevent the occurrence of colic. / Este trabalho teve como objetivo avaliar a sensibilidade ? insulina em eq?inos alimentados com dieta com n?veis elevados de carboidratos sol?veis escolhidos por conveni?ncia. O estudo foi realizado no 2o Regimento de Cavalaria e Guarda - Regimento Andrade Neves, na cidade do Rio de Janeiro, durante os anos de 2007 e 2008. Durante nove meses consecutivos, de Fevereiro a Outubro de 2007, os eq?inos eram submetidos ? coleta sangu?nea em jejum e avaliado o escore e peso corporal. O sangue foi coletado em tubos de vacutainer heparinizados e fluoretados e as amostras foram centrifugadas, amostradas e transportadas refrigeradas at? o laborat?rio EQUILAB na Universidade Federal Rural do Rio de Janeiro, onde eram armazenadas em freezer a 20 0C. O plasma foi submetido a determina??o de glicose por espectofotometria e a insulina por radioimunoensaio. Os proxies basais foram calculados na avalia??o da sensibilidade insul?nica e a resposta secret?ria insul?nica. As amostras de feno e ra??o comercial foram coletadas mensalmente para an?lise bromatol?gica. Ao t?rmino do ensaio, o ?ndice glic?mico do concentrado comercial foi avaliado em seis eq?inos do grupo experimental. N?o houve correla??o entre a incid?ncia de c?lica com idade, sexo, concentra??o plasm?tica de glicose e insulina, MIRG e RISQI e resist?ncia ? insulina. Os animais com c?lica apresentaram tend?ncia (P = 0,072) a ter um maior escore corporal comparado aos animais sem c?lica durante o per?odo avaliado. Os eq?inos com c?lica apresentavam menor peso do que animais sem c?lica (P < 0,05) os eq?inos com peso menor maior correla??o com a incid?ncia de c?lica, logo sugere que estes animais t?m maior quantidade de massa de gordura. A sensibilidade a insulina foi maior nos meses de maior atividade f?sica. Os resultados deste estudo indicam que a atividade f?sica ? a preven??o mais efetiva da resist?ncia a insulina e, ao mesmo tempo, auxilia na redu??o da gordura corporal e indiretamente pode prevenir a incid?ncia de c?licas.
60

Avalia??o do perfil de atividade da azitromicina frente a isolados bacterianos provenientes de processos infecciosos em animais de companhia. / Bacterial susceptibility pattern assessment of azithromycin in different sites of infection in pet animals

Pereira, Ingrid Annes 28 February 2007 (has links)
Made available in DSpace on 2016-04-28T20:15:24Z (GMT). No. of bitstreams: 1 2007- Ingrid Annes Pereira.pdf: 915318 bytes, checksum: 2dd2600d64dd3aa95cfa91ab1bd4177c (MD5) Previous issue date: 2007-02-28 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Antimicrobial resistance is a complex question that concerns a variety of bacterial species and resistance mechanisms, which in part can be transmitted from pet animals to the owners by theirs strict contact. The prescription of antimicrobial agents in the veterinary practices, without previous identification of the etiologic agent and its antimicrobial susceptibility pattern associated with the large use of antimicrobials applied in human medicine represent a potential source for the spread of resistant strains in animal reservoir. Azithromycin widely used in human medicine, presents bacteriostatic activity against several infectious agents, and recently it was released in Brazilian veterinary practices as an alternative for the treatment of urinary, respiratory, oral and skin infections. This work evaluated the activity pattern of azithromycin to different bacterial infections from pet animals, by the identification of the etiologic agent and its antimicrobial susceptibility pattern, and also determinate MIC values and evaluate cross-resistance to oxacilin and azithromycin in Staphylococcus spp., as a proposal to construct the real frame of azithromycin resistance in our region so as its use represent a reliable alternative in veterinary medicine. The samples were collected from different sites of infection in dogs and cats, like otitis externa, pyoderma, infections from the urinary, reproductive and respiratory tract, oral and conjuntival mucosas. The most prevalent bacterial agents were coagulase-positive Staphylococcus spp., followed by Entorabacteiaceae, coagulase-negative Staphylococcus spp., and Pseudomonas spp.. The isolates were most sensible to ampicilin+sulbactam, gentamicin, fluoroquinolones and some cephalosporins. The bacterial isolates showed an expressive azithromycin resistance, with exception of the isolates from urinary tract infection. Different tests were used to access the activity pattern of azithromycin, such as Disc Diffusion and Broth Microdiluition that detected 48,6% and 55% of resistants Staphylococcus spp., and 55,3% e 72,7% of resistants Gram-negative rods. Staphylococcus aureus MIC50 were 4,0 &#956;g/mL, S. intermedius 1,0 &#956;g/mL, coagulasenegative Staphylococcus &#8805;512 &#956;g/mL and Gram-negative rods were 256 &#956;g/mL. In nine (15%) isolates of oxacilin-resistant and mecA-positive Staphylococcus spp. were also possible detect azithromycin resistance. For this reasons, the laboratories investigations are necessary for the identification of the etiologic agents of bacterial infections and to determine its susceptibility to antimicrobials, for the best choice of treatment, and to impair the emergence of resistant bacteria that can be transmitted between animals and human, like what happens in oxacilin-resistant Staphylococcus spp.. The emergence of azithromycin resistance leads to the necessity of reliable data on the concern of the activity pattern of this antimicrobial and its contribution for the veterinary medicine practices without producing impact in development and spread of resistant strains. / A resist?ncia antimicrobiana ? um problema complexo, que envolve in?meras esp?cies bacterianas e diferentes mecanismos, podendo ter sua transmiss?o facilitada pelo estreito conv?vio entre animais de companhia e seus propriet?rios. A pr?tica de prescrever antibioticoterapia sem pr?via identifica??o do agente etiol?gico e do seu perfil de suscetibilidade associada ao amplo uso de antimicrobianos aplicados ? medicina humana representam potenciais fatores para a dissemina??o de cepas resistentes em reservat?rios animais. A azitromicina, j? amplamente utilizada no tratamento de infec??es em humanos, apresenta atividade bacteriost?tica contra uma gama de agentes infecciosos e est? dispon?vel atualmente para a cl?nica veterin?ria brasileira como alternativa de tratamento em processos infecciosos dos sistemas genito-urin?rio, respirat?rio, oral e pele. Dessa forma, o presente estudo avaliou o espectro de atividade da azitromicina, em diversos processos infecciosos bacterianos de animais de companhia, estabelecendo o pat?geno prevalente, seu perfil de suscetibilidade aos f?rmacos de elei??o, al?m de determinar a CIM da azitromicina e avaliar a poss?vel resist?ncia cruzada em Staphylococcus spp. oxacilina e azitromicina-resistentes, de forma a obter dados significativos para a constru??o do quadro real de resist?ncia ? azitromicina em nossa regi?o, para que seu uso represente uma alternativa terap?utica confi?vel em Medicina Veterin?ria. As amostras estudadas foram coletadas de diferentes processos infecciosos de c?es e gatos, tais como, otites externas, piodermas, infec??es do trato genito-urin?rio, respirat?rio, cavidade oral e da mucosa conjuntival. Os agentes bacterianos mais prevalentes foram Staphylococcus spp. coagulasepositivos, seguidos pelas enterobact?rias, Staphylococcus spp. coagulase-negativos e Pseudomas spp. De modo geral, os isolados foram mais sens?veis a ampicilina+sulbactam, gentamicina, fluoroquinolonas e algumas cefalosporinas. A azitromicina apresentou percentuais de resist?ncia significativos, com exce??o dos isolados de infec??es do trato urin?rio. Diferentes testes foram utilizados para avalia??o do perfil de atividade da azitromicina dentre estes, a Difus?o em Disco e a Microdilui??o em Caldo, detectaram resist?ncia em 48,6% e 55% dos isolados de Staphylococcus spp., respectivamente e 55,3% e 72,7% dos bastonetes Gram-negativos. A CIM50 para S. aureus foi 4,0 &#956;g/mL, para S. intermedius 1,0 &#956;g/mL, Staphylococcus spp. coagulase-negativos &#8805;512 &#956;g/mL e bastonetes Gram-negativos 256 &#956;g/mL. Em nove isolados (15%) de Staphylococcus spp. resistentes ? oxacilina e mecA positivos foi poss?vel tamb?m detectar resist?ncia ? azitromicina. Logo, a investiga??o laboratorial de doen?as bacterianas ? necess?ria para identificar o agente etiol?gico e determinar a suscetibilidade aos antimicrobianos a fim de selecionar o f?rmaco ideal e limitar o desenvolvimento de resist?ncia, uma vez que bact?rias resistentes podem ser transmitidas entre animais e desses para o homem, como j? observado em isolados de Staphylococcus spp. resistentes ? oxacilina. O desenvolvimento de resist?ncia a azitromicina aponta para a necessidade de estudos que forne?am dados confi?veis a respeito do perfil de atividade desse f?rmaco de forma a contribuir na terap?utica veterin?ria sem causar impacto no desenvolvimento e dissemina??o de cepas resistentes.

Page generated in 0.4761 seconds