71

Ventilação não invasiva pós extubação na prática clínica de um hospital terciário: um estudo de coorte / Noninvasive ventilation in postextubation outside clinical trials: cohort study

Maise Cala Figueirôa 08 July 2011 (has links)
INTRODUÇÃO: A insuficiência respiratória pós-extubação é um evento comum após a descontinuação da ventilação mecânica, sendo a reintubação necessária em cerca de 10% (4-24%) dos casos. A ventilação não invasiva (VNI) tem sido considerada como uma terapia promissora para evitar a reintubação, sendo aplicada como um adjunto para extubação precoce, de forma preventiva ou em pacientes que desenvolveram insuficiência respiratória pós extubação. OBJETIVO: Comparar as características clínicas e os desfechos da população de estudo, de acordo com as três formas de aplicação da VNI no período pós extubação. MÉTODOS: Estudo observacional prospectivo em 11 Unidades de Terapia Intensiva por um período de nove meses, onde todos os pacientes adultos submetidos à VNI dentro de 48h após a extubação foram avaliados. RESULTADOS: Um total de 174 pacientes foi incluído no estudo. A média(DP) de idade foi de 56 (18) anos e 55% eram do sexo masculino. A média (DP) do SAPS II foi de 42(14). As formas de aplicação da VNI foram: Insuficiência respiratória pós-extubação (G-IRpA) (26%), como adjunto no desmame precoce (G-PRECOCE) (10%) e como VNI preventiva (G-PREVENT) (64%). O tempo mediano de tempo de ventilação mecânica foi similar nos três grupos (66h), o tempo mediano entre a extubação e o inicio da VNI foi de 0h (0-16h), e o tempo mediano entre a extubação e a reintubação foi de 2 dias (0,7-4d). Apenas 3% dos pacientes tinham DPOC. A taxa de sucesso da VNI foi de 67% no G-IRpA, 70% no G-PRECOCE e 64% no G-PREVENT, com taxa de reintubação de 34%. A taxa de mortalidade na UTI foi de 27%. Pacientes com hipercapnia tiveram uma taxa de sucesso maior (81%), já os pacientes que necessitaram de aspiração de secreção e que passaram mais tempo na VNI foram mais susceptíveis a serem reintubados. CONCLUSÃO: A VNI pode reduzir as taxas de reintubação em pacientes que apresentaram insuficiência respiratória pós extubação, apresentar um sucesso moderado em pacientes heterogêneos que a utilizaram no desmame precoce e quando utilizada em uma população não seleta de forma preventiva, não reduz, significativamente, as taxas de mortalidade e de reintubação / BACKGROUND: Respiratory failure after extubation is a common event and reintubation occurs in 10% (4-24%) of patients. Studies suggests that noninvasive ventilation (NIV) may be successfully used to avoid reintubation, being applied as an adjunct to an early extubation, to prevent postextubation respiratory failure or in patients who developed postextubation respiratory failure. OBJECTIVE: Observe the outcomes from daily routine standard use of NIV in postextubation in its three different forms of application. METHODS: A prospective observational study in 11 Intensive Care Units (ICU), was conducted over a 9 months period, it was evaluated all adult patients submitted to NIV within 48hs after extubation. RESULTS: A total of 174 patients were included in this study. The mean (SD) age was 56 (18) years, and 55% were male. The mean (SD) SAPS II was 42 (14). NIV forms of application were: (G-IRpA) posextubation respiratory failure (26%), (G-PRECOCE) as an adjunct to an early extubation (10%) and (G-PREVENT) NIV preventive (64%). The median time of mechanical ventilation was similar in the 3 groups (66 h), the median time between extubation and beginning of NIV was 0h (0-16h), and the median time between extubation and need of reintubation was 2 days (0,7-4d). There were only 2,8% COPD patients. NIV success rate was 67% in G1, 70% in G2 and 64% in G3, with reintubation rate of 34%. Mortality rate in ICU was 27%. Patients with hypercapnia had a higher success rate (80,6%), yet patients that needed secretion aspiration and that spent more time in NIV were more susceptible to be reintubated. CONCLUSION: NIV may reduce the reintubation rate in patients with respiratory failure after extubation, present a moderate success in heterogeneous patients who used in early weaning and when used in a non selected population in a preventive way does not reduce mortality and reintubation rates
72

Efeitos da lesão pulmonar induzida pela ventilação mecânica sobre o epitélio das vias aéreas de condução e sua influência no aparelho mucociliar: modelo experimental em coelhos / Effects of ventilator-induced lung injury on airway-ciliated epithelia and the influence on mucociliary transport system

Vivien Schmeling Piccin 30 March 2010 (has links)
A ventilação mecânica (VM) pode ser causa de lesão pulmonar sendo este fato reconhecido na literatura como Lesão Pulmonar Induzida pela Ventilação Mecânica (LPIV), onde alterações tanto fisiológicas quanto morfológicas são evidenciadas no pulmão. O objetivo desse trabalho foi avaliar a repercussão das forças envolvidas na ventilação mecânica através de diferentes mecanismos de LPIV sobre o sistema mucociliar pela análise funcional e histopatológica desse aparelho. Em um estudo controlado e randomizado vinte e sete coelhos machos da raça Nova Zelândia foram separados em quatro grupos. Nos primeiros trinta minutos foram submetidos à VM com volume corrente de 8 ml/kg peso, fluxo de 3 L/minuto, e pressão positiva expiratória final (PEEP) de 5 cm H2O e FIO2 de 0,4, sendo que o grupo Sham (n=6) foi ventilado por apenas 10 minutos. Os grupos Baixo Volume/BV (n=6; Vt 8, Ppico 17, Pmédia 9, PEEP 5, Fluxo 3), Alto Volume/AV (n=7; Vt 16, Ppico 27, Pmédia 12, PEEP 5, Fluxo 5) e Alta Pressão/AP (n=8; Vt 8, Ppico 30, Pmédia 20, PEEP 12, Fluxo 9) foram ventilados por mais 3 horas. A mecânica do sistema respiratório foi registrada pelo sistema Labview®. Foram acompanhados os valores de gasometria e sinais vitais. Amostras de tecido pulmonar foram coradas com H&E para análise de infiltrado inflamatório. Analisou-se a frequência de batimento ciliar (FBC), transporte mucociliar na traqueia (TMCT), transportabilidade em palato de rã (MCT) e ângulo de contato (AC). Amostras de pulmão e traquéia foram coradas pela técnica PAS/AB para avaliação do muco. Observamos diminuição da complacência do sistema respiratório (p<0,05) no grupo AP em comparação com os demais grupos ventilados. Os grupos BV, AV e AP apresentaram um aumento de células polimorfonucleares por área de parênquima pulmonar (p<0,001) em comparação com o grupo Sham. Não foram observadas diferenças quanto ao TMCT e AC nos grupos ventilados. A transportabilidade em palato diminuiu no grupo BV (p=0,007) ao final do protocolo de ventilação (1,42 com variações de 2,11-0,99 para 0,95 com variações de 1,15-0,92). A FBC diminuiu (p=0,047) no grupo AP quando comparamos os valores iniciais (13,51 variação de 14,49-11,62) e finais ao protocolo de VM (11,69 variação de 14,18-10,12). Respostas fisiológicas e microscopia eletrônica (ME) da traquéia corroboram a disfunção da FBC no grupo AP. Na traquéia os grupos ventilados apresentaram uma diminuição da quantidade de muco total (BV 2.018, AV 3.219 e AP 2.883) e de muco ácido (BV 672, AV 240 e AP 480) por m2 de tecido pulmonar por campo estudado (p<0.05) quando comparados com o grupo Sham (4.660 m2 de muco total e 1.873 m2 de muco ácido). Em bronquíolos distais a quantidade de muco total diminuiu nos grupos BV e AP (p<0.05) quando comparados aos grupos Sham e AV. O mesmo fenômeno foi observado com relação ao muco neutro. Concluímos que as forças geradas pela ventilação mecânica têm impacto direto sobre o aparelho mucociliar, alterando suas propriedades funcionais e sua morfologia. Aparentemente a VM acarreta desequilíbrio na produção de muco, sendo essa alteração mais visível quando utilizado um alto volume corrente e uma maior pressão média pulmonar (associada a um fluxo de ar aumentado). O aumento da pressão média com alto fluxo dos gases ventilados também ocasiona maior sofrimento celular do aparelho mucociliar, disfunção da frequência de batimento ciliar e provável perda ciliar. Tais alterações se devem provavelmente ao efeito das forças físicas geradas pela VM associadas a prováveis oscilações na resposta inflamatória e no fluxo sanguíneo local. / Mechanical ventilation (MV) can result in a medical complication named Ventilator-Induced Lung Injury (VILI), where physiologic and morphologic alterations in the lungs have been reported. In this study, we have hypothesized that MV-induced injury can have a major impact on the mucociliary system. In a randomized controlled trial twenty-seven male New Zealand rabbits were separated into four groups. During the first thirty minutes all rabbits were subjected to MV with tidal volume of 8 ml/kg of body weight, 3 L/minute of flow, positive end expiratory pressure (PEEP) of 5 cm H2O and FIO2 of 0.4. After that the study animals were divided into 4 groups: Sham (n=6) was ventilated for ten minutes, Lower Volume/LV (n=6; Vt 8, P peak 17, P mean 9, PEEP 5, Flow 3), High Volume/HV (n=7; Vt 16, P peak 27, P mean 12, PEEP 5, Flow 5) and High Pressure/HP (n=8; Vt 8, P peak 30, P mean 20, PEEP 12, Flow 9) and ventilated for 3 hours more. Respiratory system mechanics was recorded using Labview®. Blood gasometry and vital signals were monitored. Lung tissue sections were stained by H&E to analyze inflammation. We also studied the ciliary beating frequency (CBF), tracheal mucociliary transport (TMCT) in situ and in vitro, mucus contact angle (CA) and respiratory mucus viscosity. To quantify mucosubstances, tracheal samples were stained with PAS/AB. As a result we have that the respiratory system compliance decreased (p<0.05) in the HP group compared to other ventilated groups. All ventilated groups showed an increase in polymorphonuclear cells quantity per area of lung parenchyma (p<0.001) compared to the Sham group. There were no differences in TMCT and CA among ventilated groups, when initial and final measurements were compared. MCT significantly decreased in the LV group (p=0.007) after the protocol (1.42 range of 2.11-0.99 to 0.95 range of 1.15-0.92). The CBF significantly decreased (p=0.047) in the HP group when the initial (13.51 range of 14.49-11.62) and final (11.69 range of 14.18-10.12) measurements were compared. Physiological data and tracheal electronic microscopy confirm the CBF dysfunction observed in the AP group. In the trachea all ventilated groups showed a significant decrease in total mucus (LV 2,018, HV 3,219 and HP 2,883) and acid mucus (LV 672, HV 240 and HP 480) per um2 of lung tissue (p<0.05) compared to the sham group (4,660 um2 of total mucus and 1,873 um2 of acid mucus). In distal bronchioles there was a significant decrease in total mucus in the LV and HP group (p<0.05) compared to Sham and HV groups. The same phenomenon was observed regarding neutral mucus. We concluded that mechanical forces involved in MV affect mucociliary function. Mechanical ventilation probably leads to the dysfunction on the mucus production. This phenomenon is better perceived when higher volume and higher mean pressure (associated with inspired gases high flow) are used. An increase of the mean pressure combined with inspired gases high flow also leads to mucociliary cells suffering, to ciliary beat frequency dysfunction and probably cilia loss. These alterations probably occur due to the effect of the physical forces generated by the mechanical ventilation in association with the oscillation of the inflammatory response and local blood flow.
73

Duração da ventilação mecânica em pediatria: impacto da introdução de avaliações diárias e teste de respiração espontânea / The impact of daily evaluation and spontaneous breathing test on the duration of pediatric mechanical ventilation: A randomized controlled trial

Flavia Andrea Krepel Foronda 25 April 2013 (has links)
Introdução: Ventilação mecânica (VM) é frequente em crianças com insuficiência respiratória aguda e está associada a complicações, sendo, portanto, necessários esforços para encurtar a sua duração. Objetivos: Verificar se a realização de avaliações diárias e testes de respiração espontânea (TRE), poderiam encurtar a duração da VM em crianças, quando comparado ao desmame habitualmente realizado em pediatria. Objetivos secundários incluíram a avaliação da taxa de falha de extubação e a necessidade de ventilação não invasiva (VNI). Desenho: Estudo prospectivo, randomizado, controlado. Ambiente: Duas unidades de cuidados intensivos pediátricos, em Hospitais Universitários no Brasil. Pacientes: Crianças entre 28 dias e 15 anos de idade que estavam recebendo VM por pelo menos 24 horas no período de julho 2007 a julho 2009. Intervenções: Os pacientes foram aleatoriamente designados para um dos dois protocolos de desmame. No grupo de teste, as crianças foram submetidas a avaliações diárias para verificar prontidão para desmame, depois foi realizado TRE com pressão de suporte de 10 cm H2O e PEEP de 5 cm H2O por um período de 2 horas. O TRE foi repetido no dia seguinte nas crianças que não passaram no primeiro teste. No grupo controle, o desmame foi realizado por critérios clínicos e laboratoriais como de rotina nas unidades. Resultados: 294 crianças elegíveis foram randomizadas, sendo 155 para o grupo de teste e 139 para o grupo controle. O tempo de VM foi menor no grupo de teste onde a duração mediana foi de 3,5 dias (95% intervalo de confiança [IC]: 3,0-4,0) em comparação com o grupo controle onde a mediana do tempo de VM foi de 4,7 dias (95% IC: 4,1-5,3) (p = 0,013). Esta redução significativa na duração da VM não foi associada a um aumento das taxas de falha de extubação ou VNI e representa uma redução de 30% no risco de permanecer em VM (Risco Relativo: 0,70). Conclusões: A avaliação diária para verificar a prontidão para o desmame combinada ao TRE reduziu a duração de VM em crianças, sem aumentar a taxa de falha de extubação ou a necessidade de VNI / Introduction: Mechanical ventilation (MV) is common in children with acute respiratory failure and is associated with several complications requiring efforts to shorten its duration. Objectives: To assess whether the combination of daily evaluation and use of a spontaneous breathing test (SBT) could shorten the duration of mechanical ventilation as compared with weaning based on our standard of care. Secondary outcome measures included extubation failure rate and the need for noninvasive ventilation (NIV).Design: A prospective, randomized, controlled trial. Setting: Two pediatric intensive care units at university hospitals in Brazil. Patients: The trial involved children between 28 days and 15 years of age who were receiving MV for at least 24 hours. Interventions: Patients were randomly assigned to one of two weaning protocols. In the test group, the children underwent a daily evaluation to check readiness for weaning and then submitted to an SBT with 10 cm H2O pressure support and a PEEP of 5 cm H2O for 2 hours. The SBT was repeated the next day for children who failed it. In the control group, weaning was performed according to standard care procedures. Measurements and main results: A total of 294 eligible children were randomized, with 155 to the test group and 139 to the control group. The time to extubation was shorter in the test group, where the median MV duration was 3.5 days (95% confidence interval [CI], 3.0 to 4.0) as compared to 4.7 days (95% CI, 4.1 to 5.3) in the control group (p=0.0127). This significant reduction in the MV duration for the intervention group was not associated with increased rates of extubation failure or NIV. It represents a 30% reduction in the risk of remaining on MV (hazard ratio: 0.70). Conclusions: A daily evaluation to check readiness for weaning combined with a SBT reduced the MV duration for children on MV for more than 24 hours, without increasing the extubation failure rate or the need for NIV
74

Avaliação da força muscular inspiratória (Pi Max), da atividade do centro respiratório (P 0.1) e da relação da atividade do centro respiratório/força muscular inspiratória (P 0.1 / Pi Max) sobre o desmame da ventilação mecânica / Evaluation of maximal inspiratory pressure (Pi Max), Airway Occlusion Tracheal Pressure (P 01) and its ratio in weaning outcome of mechanical ventilation

Sérgio Nogueira Nemer 07 May 2007 (has links)
Introdução: a hipótese deste estudo é de que a Pressão inspiratória máxima, Pressão de oclusão traqueal e sua razão podem predizer a evolução do desmame da ventilação mecânica em uma população mista de Terapia Intensiva. Métodos: A Pi Max , P 0.1 e a razão P 0.1 / Pi Max foram mensuradas em setenta pacientes consecutivos , intubados ou traqueostomizados, e ventilados mecanicamente, que preencheram os critérios para desmame da ventilação mecânica. Após a mensuração da Pi Max, P 0.1 e ainda da freqüência respiratória e volume corrente em litros com o cálculo da relação FR/VC e do produto P 0.1 x FR/VC, os pacientes foram submetidos a um teste de respiração espontânea. Os pacientes que toleraram o teste de respiração espontânea e não precisaram retornar para a ventilação mecânica no período de 24 horas foram considerados desmamados. A sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo, diagnóstico de acurácia e a área sob a curva ROC (receiver operating characteristic curve) foram calculadas. Resultados: Os valores médios da P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram de 2,49±1,2, -34,6±13, 0,07±0,01, 75,4±33 e 184,6±123 respectivamente para os pacientes desmamados e 4,36± 2,0, -32,1±11,0 , 0,15± 0,09, 148,4± 42 e 652,9± 358 para os não desmamados da ventilação mecânica. Todos os índices distinguiram entre os pacientes desmamados e não desmamados, à exceção da Pi Max. A sensibilidade para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi de 78,85, 65,38, 80,77, 82,69, 88,46 respectivamente. A especificidade para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi de 72,2, 38,8, 72,2, 83,3, 72,2 respectivamente. Os valores preditivos positivos para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente 89,1, 75,5, 89,3, 93,4 e 90,2. Os valores preditivos negativos para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente de 54,1, 28,0, 56,5, 62,5 e 68,4. O diagnóstico de acurácia para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi respectivamente de 77,1, 58,5, 78,5, 82,8 e 84,2. As áreas abaixo da curva ROC para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente 0,76± 0,06, 0,52±0,08 , 0,78±0,06, 0,90±0,04 e 0,84±0,05. A comparação da áreas abaixo da curva ROC mostrou que os melhores índices foram a relação FR/VC, o produto P 0.1 x FR/VC e a relação P 0.1 / Pi Max não havendo diferença estatística entre eles. A pior área abaixo da curva ROC foi do índice Pi Max. Os índices de desmame da ventilação mecânica P 0.1, Pi Max e P 0.1/ Pi Max não foram diferentes estatisticamente entre os pacientes intubados e traqueostomizados. Conclusão: os melhores índices foram a relação FR/VC, o produto P 0.1 x FR/VC e a relação P 0.1 / Pi Max não havendo diferença estatística entre eles. / Introduction: We hypothesized that maximal inspiratory pressure (Pi Max), airway tracheal occlusion pressure (P 0.1) and its ratio (P 0.1/Pi Max) can be used to predict weaning outcome in a mixed ICU mechanically ventilated patients. Methods: Pi Max, P 0.1 and P 0.1 / Pi Max ratio were measured in seventy consecutive intubated or tracheostomized, mechanically ventilated patients, who fulfilled weaning criteria. After these measurements of Pi Max, P0.1, respiratory rate and expiratory tidal volume (L) with the calculation of f / Vt ratio and the product P0.1x f / Vt , the patients were submitted to a spontaneous breathing trial (SBT) . Those who were able to sustain the SBT and had no need to return to mechanical ventilation in the following 24 hours were considered weaned. The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and Receiver- operating-characteristics (ROC) curves for this population were calculated. Results: The mean value of P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC were 2,49 ±1,2, -34,6± 13, 0,07± 0,01, 75,4±33 and 184,6±123 respectively for the weaned patients and 4,36± 2,0, -32,1±11,0 , 0,15± 0,09, 148,4± 42 e 652,9± 358 for the not weaned patients. All the indexes distinguished between the weaned and not weaned patient, except for the Pi Max. The sensitivity for the P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 78,85, 65,38, 80,77, 82,69, 88,46. The specificity for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were 72,2, 38,8, 72,2, 83,3, 72,2 respectively. The positive predictive value for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 89,1, 75,5, 89,3, 93,4 e 90,2. The negative predictive value for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 54,1, 28,0, 56,5, 62,5 e 68,4. The diagnostic accuracy for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 77,1, 58,5, 78,5, 82,8 e 84,2. The area under the ROC curves for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 0,76± 0,06, 0,52±0,08 , 0,78±0,06, 0,90±0,04 e 0,84±0,05. The comparison among the areas under the ROC curves showed that the best weaning indexes were f / Vt ratio, the product P 0.1 x f / Vt and the P0.1/ Pi Max ratio with no statistic differences among them. The Pi Max presented the smaller area under the ROC curve. The weaning indexes P 0.1, Pi Max e P 0.1/ Pi Max were not statistically different between intubated or tracheostomized patients. Conclusion: The best weaning indexes were f/Vt ratio , the product P 0.1 x f/Vt and the P 0.1 / Pi Max ratio with no statistically difference among them.
75

Análise dos critérios para ajuste do suporte ventilatório da ventilação mecânica / Analysis of criteria for ventilatory support adjustment of mechanical ventilation

Renata Pletsch Assunção 22 November 2016 (has links)
Introdução: A assistência ventilatória adequada é imprescindível para o tratamento do paciente ventilado artificialmente. A busca por parâmetros para realizar o ajuste ótimo e que tenham aplicação fácil a beira leito como, por exemplo, métodos não-invasivos, são desejáveis. Objetivo: analisar a acurácia diagnóstica das variáveis do padrão respiratório, da P0.1 esofágica e traqueal, para o ajuste da assistência ventilatória em pressão de suporte. Métodos: Vinte e sete pacientes internados em unidade de terapia intensiva foram consecutivamente incluídos no estudo. Todos pacientes estavam no modo de pressão de suporte, que foi aumentada para 20 cmH2O e diminui em passos de 3 cmH2O, até 2 cmH2O ou antes se o paciente apresentasse sinais de desconforto respiratório. Os pacientes foram monitorizados com cateteres para medidas de pressão esofágica e gástrica, com uma peça proximal ao tubo para mensurar a pressão traqueal a partir da oclusão da via aérea e com um pneumotacógrafo para medidas de fluxo. Durante todos níveis de suporte, foram gravados os dados dos cateteres esofágicos, gástricos, da traquéia, dados hemodinâmicos e do padrão respiratório. O ajuste da assistência ventilatória foi classificado como adequado, insuficiente e excessivo de acordo com critérios pré-estabelecidos. Resultados: Foram analisados 210 períodos com diferentes pressões de suporte e em 49% destes períodos a assistência foi excessiva, enquanto em 3,8% a assistência foi insuficiente. No início do estudo, enquanto os pacientes ainda estavam com a assistência ventilatória ajustada pela equipe assistente, 48,2% apresentavam assistência ventilatória excessiva. Pela pequena incidência de períodos com assistência ventilatória insuficiente, não foi avaliado a acurácia das variáveis para diagnóstico de assistência insuficiente. Para diagnosticar assistência ventilatória excessiva, a variável do padrão respiratório que se mostrou mais acurada foi a frequência respiratória, com sensibilidade de 90% e especificidade de 88% quando a frequência respiratória foi menor que 17 incursões por minuto. Outras variáveis do padrão respiratório não mostraram elevada acurácia. Também para o diagnóstico de assistência excessiva, foi elevada a acurácia da P0.1 esofágica (sensibilidade de 81% e especificidade de 70% quando P0.1 <= 1,9) e da P0.1 traqueal (sensibilidade de 81% e especificidade de 70% quando P0.1 <= 2,1). Conclusão: A ocorrência de assistência ventilatória excessiva foi significativamente maior que a assistência ventilatória insuficiente. A frequência respiratória menor que 17 foi a variável do padrão respiratório com maior acurácia para diagnosticar assistência ventilatória excessiva. As P0.1 esofágica e traqueal também tiveram acurácia elevas, mas menores que a frequência respiratória . / Introdution: The adequate assistance is essential for the treatment of mechanically ventilated patient. The search of parameters to achieve the optimal adjustment and with easy application to bedside, for example, non-invasive methods. Objective: Analyze the diagnostic accuracy of the breathing pattern variables, esophageal and tracheal P0.1 for adjustment of mechanical ventilation in pressure support ventilation. Methods: Twenty-seven patients in intensive care unit were consecutively included in the study. All patients were in the pressure support mode, which was raised to 20 cmH2O and decreased in steps of 3 cmH2O up to 2 cmH2O or earlier if the patient had signs of respiratory distress. Patients were monitored with catheters for esophageal and gastric pressure measurements, with the T-piece was used close to the tube to measure tracheal pressure during an airway occlusion and a pneumotachograph for flow measurements. Data was recorded for all support levels to esophageal, gastric, and tracheal pressures, also hemodynamic data and ventilatory pattern. The adjustment of mechanical ventilation was classified as adequate assistance, overassistance and underassistance according to pre-established criteria. Results: Two hundred and ten periods were analyzed with different pressures of support and 49% of these periods were overassistance, while 3,8% these periods were underassistance. At baseline, while patients were still ventilatory assistance set by assistance staff, 48,2% had overassistance. Due to the low incidence of periods with underassistance, the variables accurancy has not been evaluated. The variable breathing pattern that was more accurate diagnosing overassistance was the respiratory rate (90% sensitivity and specificity of 88 % when the respiratory rate was less than 17 breaths per minute). Other variables of the breathing pattern did not show high accuracy although esophageal P0.1 (sensitivity 81 % and specificity of 70 % when P0.1 <= 1,9) and tracheal P0.1 (sensitivity 81 % and specificity of 70 % when P0.1 <= 2,1) were high accuracy diagnosing overassistance. Conclusion: The occurrence of overassistance was significantly higher than underassistance. The respiratory rate below 17 was the variable breathing pattern more accurate to predict overassistance. The esophageal and tracheal P0.1 also had high accuracy but lower than the respiratory rate
76

Avaliação comportamental de crianças com Síndrome do Respirador Bucal / Behavioral evaluation of children with Mouth Breathing Syndrome

CASTELO BRANCO, Marília Fontes de 03 May 2012 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-05-07T12:19:37Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoComportamentalCriancas.pdf: 1187375 bytes, checksum: 4da6f01e5f8770fb043c13db6d911e18 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-09-12T13:57:23Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoComportamentalCriancas.pdf: 1187375 bytes, checksum: 4da6f01e5f8770fb043c13db6d911e18 (MD5) / Made available in DSpace on 2014-09-12T13:57:23Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoComportamentalCriancas.pdf: 1187375 bytes, checksum: 4da6f01e5f8770fb043c13db6d911e18 (MD5) Previous issue date: 2012 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / A Síndrome do Respirador Bucal (SRB) ocasiona características físicas e comportamentais que interferem na qualidade de vida da criança. O Transtorno do Déficit de Atenção e Hiperatividade (TDAH) pode estar relacionado à respiração bucal no indivíduo, bem como a presença de Distúrbios Respiratórios do Sono (DRS). Por outro lado, estudos indicam que a adenotonsilectomia reduz a ocorrência de comportamentos sugestivos de TDAH em portadores de SRB, bem como produz melhora significativa nos DRS. Pretendeu-se caracterizar a condição sociodemográfica e de risco e analisar padrões comportamentais indicadores de TDAH e os hábitos de sono de crianças com diagnóstico de Síndrome do Respirador Bucal, observados antes e após a realização de cirurgia de adenoidectomia, tonsilectomia ou adenotonsilectomia. Participaram 44 crianças, de ambos os gêneros, entre dois e 12 anos de idade, atendidas pelo Serviço de Otorrinolaringologia de um hospital universitário, assim como seus cuidadores e professores. A coleta de dados foi realizada mediante aplicação de: (1) Roteiros de entrevistas denominados Informações sobre a família e a criança e História desenvolvimental e médica, aplicados com os cuidadores; (2) Lista de Verificação Comportamental para Crianças – versão para pais (CBCL) e dos critérios para diagnóstico de TDAH do DSM-IV; (2) Lista de Verificação Comportamental para Crianças – versão para professores (TRF); (3) Inventário dos hábitos de sono para crianças pré-escolares e Questionário sobre o comportamento do sono, para escolares; (4) Avaliação comportamental pós-cirúrgica, utilizando-se o CBCL e os Inventários do sono, após dois meses da cirurgia; e (5) Entrevista devolutiva. Os respiradores bucais em sua maioria: (a) eram crianças em período escolar; (b) entre sete e nove anos de idade; (c) do gênero feminino; (d) seu principal cuidador tinha o Ensino Médio Completo; (e) renda familiar mensal entre um e dois salários mínimos; (f) constituição familiar original; e, (g) encontravam-se em risco psicossocial moderado. Observou-se que a maioria das crianças deste estudo teve uma gestação dentro de padrões considerados como normais e seu nascimento se deu de forma adequada; no entanto, uma parcela de respiradores bucais desta amostra ficou cianótica durante ou imediatamente após o parto e apresentou problemas respiratórios nos primeiros meses de vida. A respeito do temperamento do bebê no primeiro ano de vida, grande parte teve dificuldade para dormir, em ser mantido ocupado e foi superativo. A maioria dos marcos desenvolvimentais ocorreu em um período considerado dentro dos padrões típicos do desenvolvimento infantil. Os problemas de saúde mais frequentes foram problemas de apetite e problemas de sono. Tanto as crianças pré-escolares quanto as escolares apresentaram melhoras nos comportamentos característicos do TDAH após a cirurgia, de acordo com dados do CBCL (p=0,723). A maioria dos itens do Inventário dos hábitos de sono para crianças pré-escolares teve redução na frequência dos hábitos inadequados e aumento dos adequados. No Questionário sobre o comportamento do sono, uma minoria apresentou problemas de sono na avaliação pós-cirúrgica e a maior parte dos problemas de sono sofreu redução de frequência. As maiores reduções ocorreram em movimenta-se muito enquanto dorme e ronca enquanto dorme (p=0,000). Sugere-se a avaliação multidisciplinar preventiva da respiração bucal e a incorporação de um grupo controle em estudos futuros, composto por indivíduos respiradores nasais. / The Mouth Breathing Syndrome (MBS) causes physical and behavioral characteristics that interfere on the child’s quality of life. The Attention Deficit Hyperactivity Disorder (ADHD) may be related to mouth breathing in the individual, as well as to the presence of Sleep Disordered Breathing (SDB). Moreover, studies indicate that adenotonsillectomy reduces the occurrence of behavior indicative of ADHD in patients with MBS, and produces significant improvement in SDB. Objectives: (a) characterize the sociodemographic condition and risk indicators of children diagnosed with MBS; (b) analyze behavioral patterns associated with ADHD and sleep habits of children diagnosed with MBS, observed before and after adenoidectomy, tonsillectomy or adenotonsillectomy. The participants were 44 children, of both genders, between two and 12 years of age, seen in the Otorhinolaryngology Department of a university hospital. The sample was also composed by these children’s caregivers and teachers. Data collection was accomplished through: (1) Application of the Child and Family Information Form and the Developmental and Medical History Form with caregivers, followed by the Child Behavior Checklist - Caregiver Version (CBCL) and the criteria for ADHD diagnosis from DSM-IV; (2) Application of the Teacher’s Report Form (TRF); (3) Application of the Sleep Habits Inventory for Preschool Children and Sleep Behavior Questionnaire, for schoolchildren; (4) Post-surgery Behavioral Evaluation, using the CBCL and the sleep inventories, two months after surgery; and (5) Follow-up interview. Mostly, the mouth breathers: a) were school children; b) were 7-9 years old; c) were female; d) their primary caregiver had completed High School; e) his/her family income was around one and two minimum wages; f) had an original family constitution; g) were at a moderate psychosocial risk. It was observed that most participants in this study went through a normal pregnancy, with no events that could cause harm, and their delivery was also performed appropriately, however, part of the mouth breathers in this sample was cyanotic during or immediately after delivery and presented respiratory problems during the first months. Regarding the baby's temper in the first year of life, most of them were hyperactive and had difficulty falling asleep and being kept busy. The majority of the mouth breathers’ developmental milestones in this study happened in a period within the typical patterns of child development. The most frequent health problems were: appetite problems; and sleep problems. A decrease in frequency of ADHD-related behaviors was observed after surgery in both preschoolers and school children, according to data from CBCL (p = 0.723). And most items in the Sleep Habits Inventory for Preschool Children had a reduction in the frequency of inappropriate habits and an increase in the frequency of appropriate behaviors. In the Sleep Behavior Questionnaire, applied to school children, it was seen that few had sleep problems in the post-surgery evaluation and most sleep problems were reduced in frequency. The greatest reductions occurred in moves a lot while sleeping and snores in his/her sleep (p = 1.000). The preventive multidisciplinary assessment of mouth breathing is suggested as well as the incorporation of a control group, composed by nasal breathers, in future studies.
77

Avaliação do consumo de oxigênio e do gasto energético durante o teste de respiração espontânea / Evaluation of oxygen consumption and resting energy expenditure during spontaneous breathing test

Alessandra Fabiane Lago 08 December 2014 (has links)
Introdução: O desmame ventilatório é definido como o processo de liberação do suporte ventilatório e como avaliação dessa fase é conduzido o Teste de Respiração Espontânea (TRE). Um dos mais utilizados modos de TRE é a Pressão Positiva Contínua em Vias Aéreas (CPAP), a qual se aplica uma pressão positiva contínua tanto na inspiração quanto na expiração. Contudo, junto com os modos ventilatórios pode ser utilizado a Compensação Automática do Tubo (ATC) cujo objetivo é compensar a resistência imposta pelo tubo endotraqueal. Objetivos: O principal objetivo deste estudo foi comparar o Consumo de Oxigênio (VO2) a o Gasto Energético (GE) pela calorimetria indireta (CI) durante o TRE em CPAP com e sem a ATC. Métodos: O estudo foi randomizado, controlado tipo cross-over com quarenta pacientes em nove leitos de um Centro de Terapia Intensiva de um hospital terciário universitário (Hospital das Clínicas de Ribeirão Preto Universidade de São Paulo, Brasil). Os participantes foram alocados aleatoriamente no grupo 1, no qual era iniciado o TRE em CPAP em uso da ATC e posteriormente em CPAP sem o uso da ATC, ou no grupo 2, no qual era iniciado o TRE em CPAP sem a ATC e em seguida CPAP com a utilização da ATC. Resultados: Cinco pacientes foram excluídos depois da randomização por falha durante o TRE. Dos trinta e cinco restantes a maioria foi do sexo masculino (51%). A média de idade foi de 61,4 ± 16,1 anos. A diferença de VO2 entre os TREs com ATC e sem ATC foi de -1,6 mL.Kg-1.min-1; p=0,23 e intervalo de confiança de 95%: (-4,36; 1,07). Em relação ao GE a diferença foi de -5,4 kcal/d-1; p=0,5 e intervalo de confiança de 95%: (-21,67; 10,79) durante a comparação dos TREs em CPAP com e sem ATC. Conclusão: Não foram observadas diferenças quando se comparou os valores relacionados ao VO2 e GE durante o TRE com e sem ATC. / Introduction: Weaning from mechanical ventilation is defined as the process of release of ventilatory support and how the evaluation of this phase is conducted in the spontaneous breathing test (SBT). One of the most used modes of SBT is the Continuous Positive Airway Pressure (CPAP)which applies a continuous positive pressure in both inspiration and expiration. However, together with the mechanical ventilation modes it can be used the Automatic Tube Compensation (ATC) which compensates the resistance imposed by the endotracheal tube. Objectives: The main goal of this study was to compare the Oxygen Consumption (VO2) and Resting Energy Expenditure (REE) by indirect calorimetry (IC) during the SBT in CPAP with and without ATC. Methods: The study was a prospective randomized, controlled crossover trial, that enrolled 40 patients, in a 9-bed Intensive Care Unit of a tertiary University Hospital. (Clinics Hospital of Ribeirão Preto Medical School, University of São Paulo, Brazil). Participants were randomly allocated in Group 1, in which it was started the SBT in CPAP with ATC and later on CPAP without ATC, or in Group 2, which was started the SBT on CPAP without ATC and then CPAP with ATC.Results: Five patients were excluded after randomization for failure of the SBT. The thirty-five remaining patients were most male (51%). The mean age of the sample was 61.4 ± 16.1 years. The difference of VO2 between the SBT with ATC and no ATC obtained a value of -1.6 mL.Kg-1.min-1; p = 0.23 and 95% confidence interval: (-4.36; 1.07). To analyze the difference of REE between the SBT with ATC and no ATC, it was obtained an estimated value of -5.4 kcal/d-1, p = 0.5 and 95% and confidence interval (-21.67; 10.79). Conclusions: There were no differences in the comparison of VO2 and REE during the SBT with and without ATC.
78

Comparação de dois metodos de mensuração da pressão inspiratoria maxima em pacientes com e sem alterações do nivel de consciencia / Comparison of two methods of measurement of maximal inspiratory pressure in patients with and without alterations of the level of conscience

Monteiro, Ludmila Soccio 11 October 2006 (has links)
Orientadores: Sebastião Araujo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T00:31:25Z (GMT). No. of bitstreams: 1 Monteiro_LudmilaSoccio_M.pdf: 1802463 bytes, checksum: 2ba5bfd3d0b955709113de784abbcd7c (MD5) Previous issue date: 2006 / Resumo: Antecedentes. A aferição da pressão inspiratória máxima (PImax) é um método efetivo para avaliação da força muscular inspiratória, usada também como método diagnóstico e como índice preditivo de desmame da ventilação mecânica. Porém, não existe consenso na literatura sobre o tempo de oclusão de vias aéreas necessário para se obter uma PImax verdadeira durante o desmame da ventilação mecânica. Objetivos. Comparar dois métodos de mensuração da PImax e avaliar se o nível de consciência interfere nos valores obtidos. Métodos. Vinte e oito pacientes de ambos os sexos, hemodinamicamente estáveis, sem sedação, com suporte ventilatório mecânico por tempo = 48 horas, com parâmetros mínimos de desmame da ventilação, foram divididos em dois grupos: pacientes com pontuação na escala de coma de Glasgow (ECGL) = 15 e ECGL < 15. A aferição foi dividida em duas fases e, em cada fase, foram realizadas três mensurações com um intervalo de um minuto entre elas, obtendo-se assim a média entre as três: a via aérea foi ocluída com uma válvula unidirecional por 20 segundos (PImaxT20), ou, por um tempo máximo de um minuto, se um platô de pressão inspiratória não fosse observado durante três inspirações consecutivas (PImaxTid). Após um descanso de 15 minutos, foram realizadas novamente as mensurações na ordem previamente estabelecida (aleatória). Resultados. A média das medidas da PImaxTid (55,8 ± 25,0 cmH2O), no grupo total (n = 28), foi maior que a média das medidas da PImaxT20 (43,1 ± 15,5 cmH2O), com p = 0,002, e o tempo médio para a obtenção da PImaxTid foi de 30,2 ± 11 segundos. Quando divididos em dois grupos, ECGL = 15 (n = 14) e ECGL < 15 (n = 14), esse tempo médio foi de 23,8 ± 7,7 e 36,7 ± 10,0 segundos, respectivamente (p = 0,0019). Conclusões. A PImaxTid, neste grupo heterogêneo de pacientes em desmame da ventilação mecânica, mostrou valores superiores àqueles da PImaxT20, especialmente naqueles com algum grau de comprometimento do estado de consciência (ECGL < 15), sugerindo que necessitem de um tempo maior de oclusão da válvula unidirecional para se atingir a PImax real. Assim, o método comumente utilizado de 20s parece ser insuficiente para se mensurar a verdadeira PImax em pacientes com ECGL < 15. Novos estudos são necessários, agora num grupo mais homogêneo de pacientes (exemplo: com comprometimento neurológico estrutural), para determinar se realmente há necessidade de um tempo de oclusão maior que 20 segundos, ou se os valores obtidos no presente estudo simplesmente representam uma supervalorização desta PImax / Abstract: Background. Maximum inspiratory pressure (PImax) is an effective parameter for the evaluation of inspiratory muscular force and an useful predictive index during weaning from mechanical ventilation (MV). However, there is no consensus in the literature concerning the time of airway occlusion necessary to get a true PImax during weaning from MV. Objectives. To compare two methods of PImax measurement and to evaluate the influence of patients¿ level of conscience (LOC) on their values. Methods. Twenty eight patients of both sexes, hemodynamically stable, without sedation, with MV support for a time = 48 hours and in a weaning process, were divided into two groups: patients with Glasgow coma scale score (GCS) = 15 and GCS < 15. PImax measurement was done in two phases and, in each phase, three measures, with an interval of one minute between them, had been carried through, getting thus the average between the three ones: the airway was occluded with an unidirectional valve for 20 seconds (PImaxT20), or, for a maximum time of one minute, if a plateau of inspiratory pressure was not observed during three consecutive inspirations (PImaxTid). After a rest of 15 minutes, PImax measurement had been carried through again in an order previously randomized. Results. The average of measures of the PImaxTid (55.8 ± 25.0 cmH2O), in the total group (n = 28), was greater that the average of the measures of the PImaxT20 (43.1 ± 15.5 cmH2O), with p = 0.002, and the average time for the attainment of the PImaxTid was of 30.2 ± 11 seconds. When divided in two groups, GCS = 15 (n = 14) and GCS < 15 (n = 14), the average times were of 23.8 ± 7.7 and 36.7 ± 10.0 seconds, respectively (p = 0.0019). Conclusions. PImaxTid, in this heterogeneous group of patients in MV weaning, has shown greater values than those of PImaxT20 especially in those with some degree of the state of LOC alteration (GCS < 15), suggesting that the formers need a longer time of airway occlusion with the unidirectional valve to reach the real PImax. Thus, the method commonly used of 20 seconds seems to be insufficient to measure the true PImax in patients with GCS <15. Further studies, now in a more homogeneous group of neurological patients (example: with structural neurological injury), are needed to verify if these patient are really dependent of a longer airway occlusion time to reach their real PImax, or if the values that have been found in the present study simply represent an overestimation of this variable / Mestrado / Pesquisa Experimental / Doutor em Cirurgia
79

Metodología para evaluar el nivel de protección respiratoria de mascarillas y respiradores ante partículas similares a las que transmiten el SARS-CoV-2 / Methodology for evaluating the level of respiratory protection of masks and respirators against particles similar to those that transmit SARS-COV-2

Chavez-Ruiz, Manuel, Rueda-Torres, Lenin, Ruffner-Camargo, Betsabé, Bellido-Achahui, Cristofer 05 October 2021 (has links)
Objetivo: Desarrollar una metodología para evaluar el nivel de protección respiratoria de respiradores, mascarillas quirúrgicas y mascarillas comunitarias que usa la población peruana, usando partículas de un tamaño similar a las que contienen al virus activo del SARS-CoV-2. Materiales y métodos: Se ha determinado una relación lineal directa entre el logaritmo de la concentración de partículas suspendidas en aire y el tiempo transcurrido; por lo cual es posible comparar la cantidad de partículas internas y externas a la mascarilla o respirador en un mismo periodo y conocer el porcentaje de protección respiratoria de cada muestra evaluada. Resultados: Se ha logrado implementar una metodología para evaluar el nivel de protección respiratoria ante aerosoles menores a 5,0 μm. Asimismo, el empleo de accesorios como ligas o ajustadores detrás de cabeza y nuca, y el uso de clips nasales robustos, incrementan significativamente el nivel de protección respiratoria ante partículas con alta probabilidad de contener al SARS-CoV-2. Conclusiones: Se observa una concordancia entre los valores de protección respiratoria obtenidos y los esperados, considerando el nivel de filtración del material empleado de cada mascarilla quirúrgica o respirador, y su nivel de ajuste. Se observó un incremento significativo en los niveles de protección respiratoria. / Objective: To develop a methodology for evaluating the level of respiratory protection provided by res- pirators, surgical masks and community face masks used by the Peruvian population; protection was evaluated against particles of a size similar to those containing active SARS-CoV-2 virus. Materials and methods: A direct linear relationship has been determined between the logarithm of the concentration of airborne particles and the elapsed time; thus, it is possible to compare the quantity of particles inside and outside of the mask or respirator in the same time period, as well as to obtain the percentage of re- spiratory protection for each evaluated sample. Results: A methodology was established to evaluate the level of respiratory protection against aerosols smaller than 5.0 μm. Also, the use of accessories such as garters or adjusters behind the head and neck, and the use of strong nasal clips, significantly increased the level of respiratory protection against particles with a high probability of containing SARS-CoV-2. Conclusions: We found concordance between the obtained respiratory protection values and those ex- pected, considering the filtration level of the material used for each surgical mask or resp s well as the tightness. A significant increase in the levels of respiratory protection was observed.
80

Redução automática versus manual da pressão de suporte no desmame de pacientes em pós-operatório: estudo controlado e randomizado / Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomized controlled trial

Taniguchi, Corinne 29 September 2008 (has links)
INTRODUÇÃO: A redução automática da pressão de suporte (PS) baseada na freqüência respiratória, ou MRV (mandatory rate ventilation) é um modo ventilatório disponível no ventilador Taema-Horus. A hipótese do estudo é que o MRV utilizado no desmame é tão efetivo quanto o desmame manual em pacientes em pós-operatório na unidade de terapia intensiva (UTI). MÉTODOS: Ao chegar à UTI, após a cirurgia, os pacientes eram randomizados em dois grupos: desmame manual ou automático. O desmame manual consistiu na redução manual da PS a cada 30 minutos mantendo a relação freqüência respiratória sobre volume corrente menor do que 80, até a PS de 5-7 cmH2O. O desmame automático baseou-se na freqüência respiratória alvo de 15 respirações por minuto (o ventilador diminui automaticamente, a PS em 1 cmH2O a cada 4 ciclos respiratórios, se o paciente mantiver a freqüência respiratória abaixo deste valor). O objetivo primário do estudo foi comparar a duração do processo de desmame. Secundariamente verificamos o nível de PS, freqüência respiratória, volume corrente, índice de freqüência respiratória sobre volume corrente, pressão positiva expiratória final, fração inspirada de oxigênio e saturação de oxigênio requeridos durante o processo de desmame. Verificamos também necessidade de reintubação e necessidade de ventilação não invasiva nas primeiras 48 horas após a extubação. RESULTADOS: Não houve diferença estatística significativa entre os 53 pacientes selecionados em cada grupo quanto ao sexo (p=0541), idade (p=0,585) e tipo de cirurgia (p=0,172). Dezenove pacientes foram excluídos durante o protocolo (quatro no grupo manual e quinze no grupo automático, p<0,05). Nove pacientes do grupo automático foram excluídos do protocolo por não se adaptarem ao modo de desmame automático. Oitenta e sete pacientes concluíram o estudo, quarenta e nove pacientes foram desmamados manualmente e trinta e oito automaticamente. A duração do processo de desmame foi de 205,41±181,27 minutos (de 30 a 840 minutos) no grupo manual, e 157,33±129,98 minutos (de 30 a 545 minutos) no grupo automático. Não houve diferença estatística significante quanto ao tempo de desmame entre os dois grupos. O nível de PS foi maior (p<0,001) e freqüência respiratória foi menor (p=0,0098) no modo MRV comparado ao modo manual, durante o processo de desmame. Não houve necessidade de reintubação em nenhum dos grupos. Houve necessidade de ventilação não invasiva em dois pacientes do grupo manual (p=0,505), ambos sofreram cirurgia cardíaca. CONCLUSÃO: A redução automática da PS foi efetiva e pode ser utilizada no desmame de pacientes no pós-operatório na unidade de terapia intensiva, se o paciente se adaptar ao algoritmo do MRV / Introduction: Automatic pressure support reduction based on a target respiratory frequency or MRV is available in the TAEMA-HORUS ventilator for the weaning process in the ICU setting. We hypothesized that MRV is as effective as manual weaning in post-operative ICU patients. Methods: There were 106 patients selected, in the post-operative period in a prospective, randomized, controlled protocol. When the patients arrived in the ICU after surgery, they were randomly assigned to traditional weaning, consisted of the manual reduction of pressure support every thirty minutes, keeping the RR/TV(L) < 80 till 5-7 cmH20 of PSV. Alternatively, they were assigned to automatic weaning, referring to MRV set with a respiratory frequency target of 15 breaths per minute (the ventilator automatically decreased the PSV level by 1 cmH20 every 4 respiratory cycles, if the patients RR was less than 15 per minute). The primary endpoint of the study was the duration of the weaning process. Secondary endpoints were levels of pressure support, respiratory rate, tidal volume (mL), RR/VT (L), PEEP levels FiO2 and SpO2 required during the weaning process, the need for reintubation and the need for non-invasive ventilation in the 48 hours after extubation. Results: There were no statistically significant differences between the 53 patients selected for each group regarding gender (p=0.541), age (p=0.585) and type of surgery (p=0.172). Nineteen patients were excluded during the trial (4 in the PSV group and 15 in the MRV group, p<0.05). Eighty-seven patients concluded the study, forty-nine patients were weaned manually and thirtyeight automatically. The weaning duration process was 205.41 ± 181.27 minutes (30 to 840 minutes) for the manual group and 157. 33± 129.98 minutes (30 to 545 minutes) for MRV group (p=0.167). PSV levels were significantly higher and RR was lower in MRV compared to that of the PSV manual reduction (p<0.05). Reintubation was not required in either group. NIV was necessary for two patients, in the manual group after cardiac surgery (p=0.505). Conclusion: The automatic reduction of pressure support was effective and can be useful for weaning patients in the post-operative period in the ICU, if the patient is receptive to the MRV algorithm