• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 27
  • 3
  • 2
  • 2
  • Tagged with
  • 118
  • 118
  • 65
  • 65
  • 36
  • 32
  • 22
  • 20
  • 20
  • 19
  • 17
  • 16
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Predição de malignidade de tumores ovarianos utilizando marcadores tumorais, índice de risco e ROMA / Prediction of malignancy of ovarian tumors using tumor markers, risk index and ROMA

Cristina Anton 29 September 2011 (has links)
INTRODUÇÃO: O câncer de ovário é o mais letal de todos os cânceres ginecológicos e requer ser tratado por ginecologistas especializados em centros terciários para se obter melhor prognóstico. Este trabalho tem como objetivo analisar e comparar quatro estratégias diferentes para predizer a benignidade ou malignidade de tumores pélvicos supostamente de origem ovariana utilizando para este fim, marcadores tumorais CA 125 e HE4, índice de risco de malignidade (IRM) e algoritmo ROMA. MÉTODOS: Neste estudo prospectivo foram avaliadas 128 pacientes com diagnóstico de tumores pélvicos supostamente de origem ovariana atendidas na Divisão de Clínica Ginecológica do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo e Instituto do Câncer do Estado de São Paulo entre julho de 2008 e janeiro 2011. Foram calculadas a sensibilidade e a especificidade e construídas curvas ROC para comparar os quatro parâmetros (CA 125, HE4, ROMA e IRM) na eficácia de diferenciar tumores ovarianos. RESULTADOS: A sensibilidade obtida para CA 125, HE4, ROMA e IRM foi de, respectivamente, 70,4%, 79,7%, 74,1% e 63,0%. A especificidade para CA 125, HE4, ROMA e IRM foi de, respectivamente, 74,2%, 66,7%, 75,8% e 92,4%. Não houve diferença na comparação das áreas abaixo da curva ROC entre os quatro parâmetros. CONCLUSÕES: Nenhum dos quatro métodos estudados é o ideal na diferenciação de tumores ovarianos. Entre os quatro parâmetros analisados o HE4 foi o parâmetro com melhor sensibilidade na diferenciação de tumores ovarianos. A acurácia dos quatro métodos é equivalente e podem ser utilizados indistintamente para referenciar pacientes para serviços especializados no tratamento de câncer de ovário / BACKGROUND: Ovarian cancer is the most lethal of all gynecological cancers and requires to be treated by gynecologic oncologists in tertiary centers accustomed to treating this disease to achieve the best prognosis. This study aims to compare four different strategies to predict the benignity or malignancy of pelvic tumors presumably of ovarian origin using, for this purpose, tumor markers CA 125 and HE4, risk malignancy index (RMI) and algorithm ROMA. METHODS: This prospective study evaluated 128 patients supposedly with ovarian tumors treated at the Divisão de Clínica Ginecológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo and at Instituto do Câncer do Estado de São Paulo between July 2008 and January 2011. We calculated sensitivity, specificity and ROC curves to compare the four parameters (CA 125, HE4, ROMA and RMI) ability to differentiate the ovarian tumors. RESULTS: The sensitivity obtained for CA 125, HE4, ROMA and RMI was, respectively, 70.4%, 79.7%, 74.1% and 63.0%. The specificity obtained for CA 125, HE4, ROMA and RMI was, respectively, 74.2%, 66.7%, 75.8% and 92.4%. There was no difference the areas under the ROC curve among the four parameters. CONCLUSIONS: None of the four studied methods is best in the differentiation of ovarian tumors. Among the four parameters analyzed, HE4 was the parameter with highest sensitivity in the differentiation of ovarian tumors. The accuracy of the four methods is equivalent and can be used interchangeably to refer patients for specialized services in the treatment of ovarian cancer
82

"Diagnóstico de rejeição cardíaca celular em pacientes transplantados: utilidade do estudo regional da função cardíaca com Doppler tecidual" / Diagnosis of cellular acute cardiac allograft rejection: usefulness of the regional study of heart function using pulsed Doppler tissue imaging

Resende, Marcos Valério Coimbra de 19 August 2005 (has links)
Para o diagnóstico de rejeição celular foi utilizado o Doppler tecidual para o estudo da movimentação miocárdica de 14 regiões de 54 pacientes transplantados que realizaram 129 biópsias endomiocárdicas do ventrículo direito. Foram comparadas as médias e desvios padrão das velocidades de movimentação entre os pacientes com e sem rejeição celular = 3A.Verificou-se que a velocidade de movimentação diastólica tardia do anel lateral do ventrículo esquerdo quando menor do que 5,6 cm/s, isoladamente, apresentou sensibilidade de 73,8% e na análise multivariada encontrou-se modelo matemático com um conjunto de seis parâmetros, com sensibilidade de 88,2% para o diagnóstico de rejeição celular = 3A / For the diagnosis of cellular acute cardiac allograft rejection pulsed tissue Doppler imaging was used for measuring myocardial wall motion of 14 sites of 54 transplant patients who underwent 129 endomyocardial biopsies.The mean and standard deviation of myocardial velocities among patients displaying or not acute rejection = 3A were compared.It was observed that the analysis of late diastolic mitral annular motion at lateral site on its own showed a sensibility of 73.8% (5.6 cm/s was the best cut off value) and in the multivariate analysis a mathematical model was found with a set of 6 parameters with a sensibility of 88.2% for the diagnosis of cellular rejection = 3A
83

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Vessani, Roberto Murad 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
84

Comparação do comprimento do úmero em fetos portadores de Síndrome de Down com o comprimento do úmero em fetos normais / Comparison of humeral length between fetuses with Down syndrome and normal fetuses

Rimena de Melo Germano da Silva 19 February 2014 (has links)
Objetivo: Comparar o comprimento do úmero em fetos portadores de síndrome de Down (T21) com o comprimento do úmero em fetos normais, utilizando instrumentos de referência da população local. Método: Estudo caso-controle retrospectivo que comparou o comprimento do úmero de fetos normais com os fetos com T21, entre 18 semanas e 23 semanas e 6 dias. Os exames dos fetos com T21 foram realizados entre 1994 e 2012. Os controles normais foram avaliados entre 2007 e 2009. Foram analisadas as médias, medianas e desvios-padrão da idade materna, idade gestacional e medida do úmero. Posteriormente, foi feita análise da correlação entre as medidas dos úmeros e a idade gestacional, sendo seus valores expressos em múltiplos da mediana (MoMs). O comprimento do úmero dos fetos com T21 foram confrontados com os fetos normais utilizando o teste t-Student. A medida do úmero foi avaliada considerando-se os níveis de corte abaixo do percentil 10, 5 e 2,5 a fim de obter as respectivas taxas de sensibilidade. Calculou-se, ainda, a razão de verossimilhança (RV). A seguir, foi utilizado um modelo linear geral tendo a idade materna como covariável para controlar na comparação. Comparou-se, também, a medida do comprimento do úmero dos fetos normais da população local com o comprimento do úmero esperado baseado na curva de Jeanty. Os testes foram realizados com nível de significância de 5%. Resultados: Foram incluídos 58 casos com T21 e 1888 controles normais. A sensibilidade do comprimento do úmero para a detecção da T21 utilizando o nível de corte abaixo do percentil 10 foi de 44,8 % com RV de 4,4, abaixo do percentil 5 foi de 34,4 % com RV de 6,9 e abaixo do percentil 2,5 foi de 31,0 % com RV de 12. O valor médio dos úmeros, em MoMs, de fetos com T21 é estatisticamente inferior ao dos fetos normais (p < 0,001), utilizando o teste t-Student. Quando controlada a idade materna na comparação entre os grupos, a diferença permaneceu estatisticamente significativa (p < 0,001). Fez-se uma análise para comparar o comprimento do úmero nos fetos normais da população local com o comprimento do úmero esperado para a curva de Jeanty, e viu-se que os fetos normais locais têm comprimento do úmero estatisticamente significante menor. Conclusões: Existe diferença estatisticamente significante entre o comprimento do úmero de fetos normais e de fetos com T21 na população local (p < 0,001). A sensibilidade para detecção de T21 foi de 44,8%, 34,4% e 31%, para o úmero abaixo do percentil 10, 5 e 2,5, respectivamente. A curva de Jeanty não tem rendimento adequado para uso como controle do crescimento umeral em fetos normais locais, acarretando com seu uso o inevitável aumento da taxa de falsos positivos de úmeros curtos / Objective: This study aimed to compare the humeral length (HL) in fetuses with Down syndrome (T21) with HL in normal fetuses, by using instruments of reference of the local population. Method: A case-control study was conducted comparing HL in normal fetuses with HL in fetuses with T21, aged between 18 weeks and 23 weeks and 6 days. Fetuses with T21 who were examined between 1994 and 2012 were included. The normal controls were evaluated between 2007 and 2009. The averages, medians, and standard deviations were obtained for maternal age, gestational age, and HL. Afterwards, we analyzed the correlation between the HL and the gestational age, with values expressed as multiples of the median (MoMs). The HLs of fetuses with T21 were compared with the HLs in normal fetuses by using Student\'s t-test. The humeri were evaluated considering the cut-off levels below the 10th, 5th, and 2,5th percentiles to obtain the sensitivity. The likelihood ratios (LR) were also calculated. Next, a general linear model was used with maternal age as a covariate to control for comparison of the groups. Comparison was also made between the HL of fetuses in the local population and the expected HL, based on the Jeanty curve. The tests were performed with a significance level of 5%. Results: The study included 58 cases with T21 and 1888 normal controls. The sensitivity of the HL to detect T21 by using a cut-off level below the 10th percentile was 44.8% with a LR of 4.4; below the 5th percentile, the sensitivity was 34.4% with a LR of 6.9; and below the 2.5th percentile, the sensitivity was 31.0% with a LR of 12. The average value of the humerus, in MoMs, of fetuses with T21 is statistically lower than that of normal fetuses (p < 0.001), as measured by using Student\'s t-test. When maternal age was controlled as a covariant in the comparison between groups, the difference remained statistically significant (p < 0.001). An analysis to compare the HL in normal fetuses of the local population with expected HL based on the Jeanty curve concluded that the HL in normal fetuses of the local population is lower than expected. Conclusions: There is a statistically significant difference between the HL of normal fetuses and HL of fetuses with T21 in the local population (p < 0.001). The sensitivity for detection of T21 was 44.8%, 34.4%, and 31% for the humerus below the 10th, 5th and 2.5th percentile, respectively. The Jeanty curve is not adequate to use as growth control for humeri in local normal fetuses, as its use leads to an increase in false positive rates when measuring the proportion of short humeri
85

Validação de sistema portátil de monitorização respiratória para o diagnóstico de apneia obstrutiva do sono em pacientes com doença arterial coronariana / Validation of portable respiratory monitoring system for the diagnosis of obstructive sleep apnea in patients with coronary artery disease

Naury de Jesus Danzi Soares 22 February 2011 (has links)
Introdução: A apneia obstrutiva do sono (AOS) é caracterizada por episódios repetidos de colapso parcial ou completo das vias aéreas superiores durante o sono, resultando em eventos respiratórios caracterizados por hipopneias ou apneias, respectivamente. Os eventos respiratórios podem resultar em fragmentação do sono, hipoxemia recorrente e geração de pressão intratorácica negativa. Todos esses mecanismos são potencialmente deletérios ao sistema cardiovascular. A AOS é comum entre pacientes com doença cardiovascular, porém ainda é pouco reconhecida. O padrão ouro para o diagnóstico da AOS é a Polissonografia (PSG) completa. O acesso a PSG completa é limitado, contribuindo para o subdiagnóstico da AOS. A poligrafia noturna de variáveis respiratórias (PGR) é um método simplificado, sendo uma alternativa promissora para o diagnóstico da AOS. No entanto, estudos de validação de PGR incluíram somente populações pré-selecionadas ou referidas para laboratórios de sono e excluíram pacientes com comorbidades significativas. Atualmente a Academia Americana de Medicina do sono reconhece o uso da PGR para o diagnóstico da AOS em pacientes com alta probabilidade pré-teste de AOS moderada a grave e em pacientes sem comorbidades significativas. Objetivo: Validar a PGR para o diagnóstico de AOS entre pacientes consecutivos avaliados para cirurgia de revascularização miocárdica, portanto, com Doença Arterial Coronariana (DAC). Avaliar a prevalência da AOS e a utilidade dos sintomas clínicos para o diagnóstico da AOS entre os pacientes com DAC. Métodos: Pacientes com indicação de revascularização do miocárdio foram avaliados através de exames clínicos e laboratoriais de rotina, escala de sonolência diurna (Epworth) e risco clínico de apneia do sono (questionário de Berlin), ecocardiograma, PSG e PGR. A PGR utilizada é classificada como tipo 3, com os seguintes canais: fluxo de ar, esforço respiratório, oximetria de pulso, frequência de pulso, ronco e sensor de posição, (Stardust II ®). Resultados: Foram estudados 70 pacientes consecutivos (76% do sexo masculino); idade (média DP) = 58 ± 7 anos, índice de massa corpórea (IMC) [mediana (25-75%)] = 27,6 (25,8-31,1) kg/m2. Vinte pacientes (29%) apresentaram fração de ejeção do ventrículo esquerdo (FEVE) 45%. A PSG da população revelou índice de apneia e hipopneia (IAH)= 2320 eventos/h. A prevalência de AOS com um IAH 5, 15 e 30 eventos/h foi de 87%, 54% e 27%, respectivamente. A sonolência diurna medida pela escala de Epworth e o risco clínico de AOS verificado pelo questionário de Berlin foram pobres preditores de AOS. A sensibilidade / especificidade da PGR para detectar AOS (IAH 5 eventos/h) e AOS grave (IAH 30 eventos/h) foram 0,92/0,67% e 0,42/0,92%, respectivamente. A média da diferença do IAH entre os dois métodos diagnósticos apresentada no Bland-Altman foi de + 5,3, indicando que os valores do IAH da PGR foram em média inferiores aos da PSG. O desvio padrão da diferença foi de 14,6 eventos/hora, apresentando uma considerável concordância entre o IAH da PSG e da PGR. Conclusão: Este estudo valida o uso da PGR para o diagnóstico da AOS em uma população de pacientes consecutivos, avaliados para revascularização do miocárdio, em quem a doença cardíaca é significativa. A prevalência de AOS entre pacientes com DAC é alta atingindo mais de 50% dessa população. No entanto, os sintomas clínicos, nessa população, não são preditores adequados de AOS. Em função da alta prevalência de AOS e baixa especificidade de sintomas clínicos, nossos dados sugerem que a PGR é um instrumento promissor para a avaliação de pacientes com DAC avaliados para cirurgia de revascularização do micárdio / Introduction: Obstructive sleep apnea (OSA) is characterized by repeated episodes of partial or complete collapse of the upper airway during sleep, resulting in respiratory events characterized by hypopnea or apnea, respectively. Respiratory events may result in sleep fragmentation, hypoxemia and recurrent generation of negative intrathoracic pressure. All these mechanisms are potentially harmful to the cardiovascular system. OSA is common among patients with cardiovascular disease, but is still poorly recognized. The gold standard for diagnosis of OSA is polysomnography (PSG). Access to full PSG is limited, contributing to the under diagnosis of OSA. The polygraph nocturnal of respiratory variables (PGR) is a simplified method, being a promising alternative for the diagnosis of OSA. However, validation studies of PGR only included populations pre-selected or referred to sleep laboratories and excluded patients with significant comorbidities. Currently the American Academy of Sleep Medicine recognizes the use of PGR for the diagnosis of OSA in patients with high pretest probability of moderate to severe OSA and in patients without significant comorbidities. Objective: Validate the PGR for the diagnosis of OSA among consecutive patients evaluated for coronary artery bypass grafting (CABG), therefore with Coronary Artery Disease (CAD). To assess the prevalence of OSA and to evaluate the usefulness of clinical symptoms for diagnosis of OSA among patients with CAD. Methods: Patients with indication of CABG were evaluated by clinical examination and routine laboratory, the scale of daytime sleepiness (Epworth) and clinical risk of sleep apnea (Berlin questionnaire), echocardiogram, PSG and PGR. The PGR use is classified as type 3, with the following channels: airflow, respiratory effort, pulse oximetry, pulse rate, snoring and position sensor, (Stardust II ®). Results: We studied 70 consecutive patients (76% male); age (mean SD) = 58 ± 7 years; body mass index (BMI), [median (25-75%)] = 27,6 (25,8 to 31,1) kg/m2. Twenty patients (29%) had left ventricular ejection fraction (LVEF) 45%. The PSG of population showed apnea-hypopnea index (AHI) = 23 20 events / h. The prevalence of OSA with an AHI 5, 15 and 30 events / h was 87%, 54% and 27%, respectively. Daytime sleepiness measured by Epworth Sleepiness Scale and the clinical risk of OSA verified by the Berlin questionnaire were poor predictors of OSA. The sensitivity and specificity to detect OSA (AHI 5 events / h) and severe OSA (AHI 30 / events) of the PGR were 0,92/0,67% and 0,42/0,92%, respectively. The average difference in AHI between the two diagnostic methods presented in Bland-Altman was + 5,3, indicating that the values of the AHI of the PGR were on average lower than the PSG. The standard deviation of the difference was 14,6 events / hour, presenting a considerable agreement between the AHI of PSG and the PGR. Conclusion: This study validates the use of PGR for the diagnosis of OSA in a population of consecutive patients evaluated for CABG, in whom heart disease is significant. The prevalence of OSA among patients with CAD is high reaching over 50% of this population. However, the clinical symptoms are not adequate predictors of OSA in this population. Due to the high prevalence of OSA and low specificity of clinical symptoms, our data suggest that the PGR is a promising tool for the assessment of CAD patients evaluated for surgery for the CABG
86

Magnetnorezonantna dijagnostika akutnog pankreatitisa / Magnetoresonant diagnosis of pancreatitis acuta

Gvozdenović Katarina 25 October 2017 (has links)
<p>Akutni pankreatitis predstavlja zbirni pojam dinamičkih, lokalnih i sistemskih patofiziolo&scaron;kih procesa nastalih iznenadnim prodorom aktivnih litičkih pankreasnih enzima u žlezdani parenhim. Cilj istraživanja je da se Utvrditi senzitivnost difuzione sekvence magnetne rezonance (DWI) radi utvrđivanja morfolo&scaron;kih promena parenhima kod akutnog pankreatitisa. Poređenje difuzione mape i difuzionog koeficijenta kod pacijenata sa akutnim pankreatitisom i kod pacijenata sa morfolo&scaron;ki urednim parenhimom pankreasa na magnetnoj rezonanci. Utvrditi da li postoje statistički značajne razlike difuzionog koeficijenta kod pacijenata sa akutnim pankreatitisom u odnosu na pol. Utvrditi da li postoje statistički značajne razlike difuzionog koeficijenta kod pacijenata sa akutnim pankreatitisom u odnosu na godine. Odrediti prelomnu tačku difuzionog koeficijenta kod pacijenata sa akutnim pankreatitisom. Studija je bila prospektivnog karaktera i obuhvatilo je 30 ispitanika sa morfolo&scaron;ki urednim parenhimom pankreasa i 30 sa dijagnozom akutnog pankreatitisa unutar 72 sata od početka simptoma. Svi pacijenti su pregledani magnetnom rezonancom u Centru za radiologiju, Kliničkog Centra Vojvodine. Rezultati ukazuju da postoje razlike difuzionog koeficijenta kod pacijenata sa akutnim pankreatitisom i kontrolne grupe. Takođe smo dokazali da difuzioni koeficijent zavisi od pola i starosti i utvrdili smo prelomnu tačku difuzije za rano dijagnostikovanje akutnog pankreatitisa.</p> / <p>Acute pancreatitis is defined as cumulative term of dynamic local and general pathophysiological processes caused by sudden penetration of active lithic pancreatic enzymes in the glandular parenchyma. Goal of this research is to note the changes (sensitivity) in values of diffusion weighted images (DWI) in acute pancreatitis and to determine morphological changes in glandular parenchyma of pancreas. Comparation of DWI between patients with acute pancreatitis and patients with normal pancreatic parenchyma based on magnetic resonance (MRI). We also want to determine whether there were statistically significant differences of DWI in patients with acute pancreatitis in relation to sex and age. One of our goals also was to determine breakpoint of DWI as a sure sign of acute pancreatitis. This was prospective study and included 30 patients with morphologically healthy parenchyma of the pancreas (control group) and 30 with the diagnosis of acute pancreatitis &ndash; in first 72 hours of the onset of symptoms. All patients were examined on MRI in department of Radiology of Clinical Center of Vojvodina. Our results indicate that was a big difference of DWI between patients with acute pancreatitis and control group. We prove that DWI depends on the sex and age. 1,77x10-6mm/s2 was breakpoint which indicates acute pancreatitis.</p>
87

Anisotropia fracionada na substância negra não é um biomarcador diagnóstico para doença de Parkinson / Substantia nigra fractional anisotropy is not a diagnostic biomarker of Parkinson\'s disease

Hirata, Fabiana de Campos Cordeiro 25 October 2018 (has links)
Estudos recentes têm sugerido que as imagens de tensor de difusão podem ser úteis para diagnosticar doença de Parkinson (DP). Nosso objetivo foi estimar a exatidão diagnóstica da anisotropia fracionada da substância negra (FA-SN) para o diagnóstico de DP, em uma amostra mais próxima do cenário clínico, incluindo pacientes com tremor essencial (TE) e voluntários sadios (VS). Para uma compreensão mais profunda de nossos achados, também realizamos uma revisão sistemática da literatura e meta-análise para estimar a mudança média da FA-SN induzida pela DP e a precisão diagnóstica dessa medida. Nossa amostra consistiu de 135 pacientes: 72 pacientes com DP, 21 com TE e 42 VS. Dois exames em RM 3T foram realizados em diferentes locais. Em nossa amostra, não encontramos diferenças significativas entre os grupos e a FA-SN não foi útil para o diagnóstico. O maior componente da variabilidade foi a interação sítio-sujeito. Os resultados desta amostra foram fundidos em uma meta-análise que incluiu 1549 indivíduos compostos de 896 pacientes com DP e 653 VS. Utilizaram-se os modelos bivariados e inversos de variância inversa para resumir as medidas de acurácia diagnóstica e as diferenças de médias, respectivamente. A meta-análise estimou uma pequena diminuição nos valores médios da FA-SN na DP (0,03 menor nos pacientes com DP (IC: 0,01 - 0,06)). Apesar disso, sua capacidade discriminatória para o diagnóstico da DP foi baixa. A sensibilidade e a especificidade combinadas foram, respectivamente, 70% (IC: 65 - 74) e 63% (IC: 57 - 69). Houve alta heterogeneidade entre os resultados dos estudos (I2 = 92%). O estudo de caso-controle e a meta-análise das medidas de anisotropia fracionada na substância negra de pacientes com doença de Parkinson e voluntários sadios demonstram que o seu uso como biomarcador de DP não é confiável / Recent studies have suggested that diffusion tensor images can be useful to diagnose Parkinson\'s disease (PD). Our goal was to estimate the diagnostic accuracy of substantia nigra fractional anisotropy (SN-FA) for PD diagnosis in a sample closer to the clinical setting, including patients with essential tremor (ET) and healthy controls (HC). To a deeper understanding of our findings, we also performed a systematic literature review and meta-analysis to estimate mean change of SN-FA induced by PD, and diagnostic accuracy of this measurement. Our sample consisted of 135 subjects: 72 PD and 21 ET patients and 42 HC. Two 3T MRI scans were performed in different sites. In our sample, we did not find significant mean difference between groups and SN-FA was useless for diagnosis. The largest component of explained variability of SN-FA was site-subject interaction. MRI results of this sample were merged in a meta-analysis that included 1549 subjects composed of 896 PD patients and 653 HC. The normal bivariate and the inverse-variance random-effect models were used to summarize diagnostic accuracy measures and mean differences respectively. Meta-analysis estimated a small decrease in mean SN-FA values in PD (0.03 lower in PD patients (CI: 0.01 - 0.06)). Despite this fact, its discriminatory capability to diagnose PD was low. The pooled sensitivity and specificity was respectively 70% (CI: 65 - 74) and 63% (CI: 57 - 69). There was high heterogeneity between studies results (I2 = 92 %). This case-control study and meta-analysis of substantia nigra fractional anisotropy measurements in Parkinson\'s disease and healthy volunteers demonstrate that their use as a PD biomarker is not reliable
88

Acurácia diagnóstica da ecocardiografia sob estresse associada ao estudo da perfusão miocárdica com contraste na avaliação da isquemia miocárdica: estudo comparativo entre adenosina e dobutamina / Diagnostic accuracy of quantitative real time myocardial contrast echocardiography for the detection of myocardial ischemia. A comparative study between adenosine and dobutamine

Kowatsch, Ingrid 23 August 2005 (has links)
A ecocardiografia com perfusão miocárdica em tempo real (EPMTR) permite a quantificação do fluxo sangüíneo miocárdico e, quando realizada durante o estresse, da reserva de fluxo miocárdico (reserva Axß). Essa técnica tem potencial para ser uma importante ferramenta para o diagnóstico não-invasivo da doença arterial coronariana (DAC). Apesar do conhecimento atual das alterações fisiológicas que ocorrem com o uso de agentes vasodilatadores ou catecolaminas na circulação coronariana, não há dados na literatura comparando diretamente o valor da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de DAC em humanos. Os objetivos deste estudo foram: avaliar, em um mesmo grupo de pacientes, a exeqüibilidade e a acurácia da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de estenose arterial coronariana angiograficamente significativa e determinar o valor adicional da análise quantitativa da perfusão miocárdica sobre o eletrocardiograma de 12 derivações, da motilidade segmentar e da análise qualitativa da perfusão miocárdica obtidas durante o estresse pela dobutamina e pela adenosina. Estudamos 54 pacientes (média etária de 60±9 anos, 33 homens) com suspeita clínica de DAC e indicação de angiografia coronariana. Todos os pacientes foram submetidos à EPMTR sob estresse pela adenosina na dose de 140 g/kg/min por seis minutos e, após um intervalo de três a cinco horas, à EPMTR sob estresse pela dobutamina-atropina. O contraste ecocardiográfico utilizado foi o PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin), administrado por via intravenosa periférica de forma contínua. Para ambas as EPMTR sob estresse pela dobutamina e pela adenosina, foram feitas análises do eletrocardiograma em 12 derivações (ECG), da motilidade segmentar e análise qualitativa e quantitativa da perfusão miocárdica. A quantificação da velocidade do fluxo miocárdico (ß) e do fluxo sangüíneo miocárdico (Axß) foi realizada por meio da utilização do programa computacional QLab 3.0 (Philips Medical Systems, Bothell, WA, USA). Todos os pacientes foram submetidos à angiografia coronariana quantitativa (ACQ) em um intervalo de até 30 dias da EPMTR. Foi considerada DAC a presença de lesão coronariana > 50% do diâmetro luminal. Dos 54 pacientes estudados, 25 (46%) apresentaram lesão coronariana >50% e 29 (54%) não apresentaram lesão coronariana significativa. A exeqüibilidade da quantificação da reserva Axß foi semelhante para a EPMTR sob estresse pela adenosina e pela dobutamina (91% versus 90% dos territórios arteriais; p = ns). A variabilidade da quantificação interobservador para os parâmetros de reserva ß e Axß foi de 6,8% (r = 0,98) e 5,5% (r = 0,97), respectivamente. A variabilidade intra-observador para os mesmos parâmetros foi de 2,1 % (r = 0,99) e 7,4 % (r = 0,95), respectivamente. A análise quantitativa da perfusão miocárdica, obtida pela EPMTR sob estresse pela dobutamina, apresentou sensibilidade de 84%, especificidade de 76% e acurácia de 80% para a detecção de DAC, enquanto que a EPMTR sob estresse pela adenosina apresentou sensibilidade de 88%, especificidade de 72% e acurácia de 80%. O valor incremental das modalidades estudadas para o diagnóstico de DAC foi analisado em modelo que incluiu o ECG, ECG e motilidade segmentar, ECG e motilidade segmentar e perfusão qualitativa e, por último, ECG e motilidade segmentar e perfusão qualitativa e quantitava, tanto para a EPMTR sob estresse pela dobutamina como pela adenosina (2 de 4,9 versus 20,1 versus 23,7 versus 38,4) e (2 de 9,9 versus 20,1 versus 26,7 versus 59,4), respectivamente. Concluímos que a avaliação quantitativa da EPMTR apresenta boa exeqüibilidade. A EPMTR sob estresse pela dobutamina e a pela adenosina apresentam acurácias diagnósticas similares para a detecção de lesão angiograficamente significativa. A análise quantitativa da perfusão miocárdica apresenta valor diagnóstico adicional aos outros parâmetros obtidos durante o estresse pela dobutamina e adenosina. / Real time myocardial contrast echocardiography (RTMCE) has allowed for the quantification of myocardial blood flow reserve (MBFR). This technique is a valuable tool for the noninvasive detection of coronary artery disease (CAD). Both adenosine and dobutamine are currently used stressor agents during RTMCE. Although it has already been shown the effects of these drugs on the coronary physiology, no study has directly compared both agents during RTMCE. The aims of this study were to determine the feasibility and diagnostic accuracy of adenosine versus dobutamine stress RTMCE for the detection of angiographically significant CAD. In addition, we sought to determine the additional value of quantitative RTMCE over the electrocardiogram, wall motion, and qualitative analysis of myocardial perfusion. The study involved 54 patients (60±9 years, 33 men) with suspected CAD. Patients underwent RTMCE at rest and during continuous infusion of 140g/kg/min of adenosine for six minutes, and dobutamine stress. The contrast agent used in the study was PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin) administered in continuous intravenous infusion. Quantification of plateau of acoustic intensity (A) and microbubble velocity () was performed off line using a specific software (QLab 3.0, Philips Medical Systems, Bothell, WA, USA). Myocardial blood flow was determined as Ax. Quantitative coronary angiography was performed in all patients within 30 days of RTMCE, and CAD was defined as >50% luminal diameter coronary stenosis. There were 25 (46%) patients with CAD and 29 (54%) patients without obstructive lesion. The feasibility of quantitative MBFR was the same for adenosine and dobutamine stress RTMCE (91% versus 90% in all arterial territories; p=ns). The intraobserver variabilities for the measurements of ß and Axß reserve were 2.1% (r = 0.99) and 7.4% (r = 0.95), respectively. The interobserver variabilities for the same parameters were 6.8% (r = 0.98) and 5.5% (r = 0.97), respectively. The sensitivity, specificity and diagnostic accuracy of ß reserve obtained during dobutamine stress RTMCE for detecting CAD were 84%, 76%, and 80%, respectively, and during adenosine stress RTMCE they were 88%, 72% and 80%. The incremental value for the diagnosis of CAD was analyzed in a model that included the EKG, EKG and wall motion, EKG and wall motion and qualitative perfusion analysis and finally, EKG and wall motion and qualitative and quantitative perfusion analysis, for dobutamine and adenosine RTMCE (2= 4,9 versus 20,1 versus 23,7 versus s 38,4) and (2= 9,9 versus 20,1 versus 26,7 versus 59,4), respectively. In conclusion, quantitative RTMCE is a feasible technique in patients with suspected CAD. Dobutamine and adenosine stress RTMCE had similar diagnostic accuracy for the detection of angiographically significant lesion. Quantitative analysis of myocardial perfusion had incremental diagnostic value over the other parameters obtained during both dobutamine and adenosine stress RTMCE.
89

Validação de sistema portátil de monitorização respiratória para o diagnóstico de apneia obstrutiva do sono em pacientes com doença arterial coronariana / Validation of portable respiratory monitoring system for the diagnosis of obstructive sleep apnea in patients with coronary artery disease

Soares, Naury de Jesus Danzi 22 February 2011 (has links)
Introdução: A apneia obstrutiva do sono (AOS) é caracterizada por episódios repetidos de colapso parcial ou completo das vias aéreas superiores durante o sono, resultando em eventos respiratórios caracterizados por hipopneias ou apneias, respectivamente. Os eventos respiratórios podem resultar em fragmentação do sono, hipoxemia recorrente e geração de pressão intratorácica negativa. Todos esses mecanismos são potencialmente deletérios ao sistema cardiovascular. A AOS é comum entre pacientes com doença cardiovascular, porém ainda é pouco reconhecida. O padrão ouro para o diagnóstico da AOS é a Polissonografia (PSG) completa. O acesso a PSG completa é limitado, contribuindo para o subdiagnóstico da AOS. A poligrafia noturna de variáveis respiratórias (PGR) é um método simplificado, sendo uma alternativa promissora para o diagnóstico da AOS. No entanto, estudos de validação de PGR incluíram somente populações pré-selecionadas ou referidas para laboratórios de sono e excluíram pacientes com comorbidades significativas. Atualmente a Academia Americana de Medicina do sono reconhece o uso da PGR para o diagnóstico da AOS em pacientes com alta probabilidade pré-teste de AOS moderada a grave e em pacientes sem comorbidades significativas. Objetivo: Validar a PGR para o diagnóstico de AOS entre pacientes consecutivos avaliados para cirurgia de revascularização miocárdica, portanto, com Doença Arterial Coronariana (DAC). Avaliar a prevalência da AOS e a utilidade dos sintomas clínicos para o diagnóstico da AOS entre os pacientes com DAC. Métodos: Pacientes com indicação de revascularização do miocárdio foram avaliados através de exames clínicos e laboratoriais de rotina, escala de sonolência diurna (Epworth) e risco clínico de apneia do sono (questionário de Berlin), ecocardiograma, PSG e PGR. A PGR utilizada é classificada como tipo 3, com os seguintes canais: fluxo de ar, esforço respiratório, oximetria de pulso, frequência de pulso, ronco e sensor de posição, (Stardust II ®). Resultados: Foram estudados 70 pacientes consecutivos (76% do sexo masculino); idade (média DP) = 58 ± 7 anos, índice de massa corpórea (IMC) [mediana (25-75%)] = 27,6 (25,8-31,1) kg/m2. Vinte pacientes (29%) apresentaram fração de ejeção do ventrículo esquerdo (FEVE) 45%. A PSG da população revelou índice de apneia e hipopneia (IAH)= 2320 eventos/h. A prevalência de AOS com um IAH 5, 15 e 30 eventos/h foi de 87%, 54% e 27%, respectivamente. A sonolência diurna medida pela escala de Epworth e o risco clínico de AOS verificado pelo questionário de Berlin foram pobres preditores de AOS. A sensibilidade / especificidade da PGR para detectar AOS (IAH 5 eventos/h) e AOS grave (IAH 30 eventos/h) foram 0,92/0,67% e 0,42/0,92%, respectivamente. A média da diferença do IAH entre os dois métodos diagnósticos apresentada no Bland-Altman foi de + 5,3, indicando que os valores do IAH da PGR foram em média inferiores aos da PSG. O desvio padrão da diferença foi de 14,6 eventos/hora, apresentando uma considerável concordância entre o IAH da PSG e da PGR. Conclusão: Este estudo valida o uso da PGR para o diagnóstico da AOS em uma população de pacientes consecutivos, avaliados para revascularização do miocárdio, em quem a doença cardíaca é significativa. A prevalência de AOS entre pacientes com DAC é alta atingindo mais de 50% dessa população. No entanto, os sintomas clínicos, nessa população, não são preditores adequados de AOS. Em função da alta prevalência de AOS e baixa especificidade de sintomas clínicos, nossos dados sugerem que a PGR é um instrumento promissor para a avaliação de pacientes com DAC avaliados para cirurgia de revascularização do micárdio / Introduction: Obstructive sleep apnea (OSA) is characterized by repeated episodes of partial or complete collapse of the upper airway during sleep, resulting in respiratory events characterized by hypopnea or apnea, respectively. Respiratory events may result in sleep fragmentation, hypoxemia and recurrent generation of negative intrathoracic pressure. All these mechanisms are potentially harmful to the cardiovascular system. OSA is common among patients with cardiovascular disease, but is still poorly recognized. The gold standard for diagnosis of OSA is polysomnography (PSG). Access to full PSG is limited, contributing to the under diagnosis of OSA. The polygraph nocturnal of respiratory variables (PGR) is a simplified method, being a promising alternative for the diagnosis of OSA. However, validation studies of PGR only included populations pre-selected or referred to sleep laboratories and excluded patients with significant comorbidities. Currently the American Academy of Sleep Medicine recognizes the use of PGR for the diagnosis of OSA in patients with high pretest probability of moderate to severe OSA and in patients without significant comorbidities. Objective: Validate the PGR for the diagnosis of OSA among consecutive patients evaluated for coronary artery bypass grafting (CABG), therefore with Coronary Artery Disease (CAD). To assess the prevalence of OSA and to evaluate the usefulness of clinical symptoms for diagnosis of OSA among patients with CAD. Methods: Patients with indication of CABG were evaluated by clinical examination and routine laboratory, the scale of daytime sleepiness (Epworth) and clinical risk of sleep apnea (Berlin questionnaire), echocardiogram, PSG and PGR. The PGR use is classified as type 3, with the following channels: airflow, respiratory effort, pulse oximetry, pulse rate, snoring and position sensor, (Stardust II ®). Results: We studied 70 consecutive patients (76% male); age (mean SD) = 58 ± 7 years; body mass index (BMI), [median (25-75%)] = 27,6 (25,8 to 31,1) kg/m2. Twenty patients (29%) had left ventricular ejection fraction (LVEF) 45%. The PSG of population showed apnea-hypopnea index (AHI) = 23 20 events / h. The prevalence of OSA with an AHI 5, 15 and 30 events / h was 87%, 54% and 27%, respectively. Daytime sleepiness measured by Epworth Sleepiness Scale and the clinical risk of OSA verified by the Berlin questionnaire were poor predictors of OSA. The sensitivity and specificity to detect OSA (AHI 5 events / h) and severe OSA (AHI 30 / events) of the PGR were 0,92/0,67% and 0,42/0,92%, respectively. The average difference in AHI between the two diagnostic methods presented in Bland-Altman was + 5,3, indicating that the values of the AHI of the PGR were on average lower than the PSG. The standard deviation of the difference was 14,6 events / hour, presenting a considerable agreement between the AHI of PSG and the PGR. Conclusion: This study validates the use of PGR for the diagnosis of OSA in a population of consecutive patients evaluated for CABG, in whom heart disease is significant. The prevalence of OSA among patients with CAD is high reaching over 50% of this population. However, the clinical symptoms are not adequate predictors of OSA in this population. Due to the high prevalence of OSA and low specificity of clinical symptoms, our data suggest that the PGR is a promising tool for the assessment of CAD patients evaluated for surgery for the CABG
90

Hapsite (R) gas chromatography - mass spectrometry with solid phase microextraction /

Kan, WaiKwong. January 2005 (has links) (PDF)
Thesis (M.S.)--Uniformed Services University of the Health Sciences, 2005. / Typescript (photocopy).

Page generated in 0.0491 seconds