• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 27
  • 3
  • 2
  • 2
  • Tagged with
  • 118
  • 118
  • 65
  • 65
  • 36
  • 32
  • 22
  • 20
  • 20
  • 19
  • 17
  • 16
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Quantification of respiratory motion in PET/CT and its significance in radiation therapy

Chakraborty, Chandrani. January 2008 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 113-115.
62

Monte Carlo simulations using MCNPX of proton and anti-proton beam profiles for radiation therapy

Handley, Stephen Michael. January 2010 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 90-92.
63

Contribuição para o diagnóstico da doença de Chagas crônica na prática clínica / Contribution to the diagnosis of chronic Chagas disease in clinical practice

Pedro Emmanuel Alvarenga Americano do Brasil 13 December 2010 (has links)
Em diferentes diretrizes para doença de Chagas crônica há diferentes algoritmos de execução de testes sorológicos. No entanto, há poucas referências quanto aos pacientes que devem ser submetidos à investigação sorológica, além dos indícios de que os testes ELISA possuem limitações e que o uso da PCR é controverso. Este trabalho contém resultados de dois estudos; o primeiro teve como objetivo rever a literatura sobre diagnóstico de doença de Chagas crônica e sumarizar a performance dos testes ELISA e PCR, e o segundo desenvolver um modelo de predição clínica para doença de Chagas crônica. O primeiro estudo foi uma revisão sistemática. Resumos relevantes foram procurados em bases remotas (MEDLINE, LILACS, EMBASE, SCOPUS, ISIWeb) e em bibliografia de textos completos. As investigações originais foram consideradas elegíveis para este trabalho quando estimassem sensibilidade e especificidade, ou confiabilidade (ou permitissem sua estimação) de testes ELISA ou PCR para o diagnóstico de doença de Chagas crônica. A heterogeneidade mostrou-se elevada em cada teste (ELISA e PCR) e o efeito de ponto de corte foi detectado em subgrupos. A sensibilidade e a especificidade sumárias do teste ELISA foram 97,7% [96,7%-98,5%] e 96,3% [94,6%-97,6%] respectivamente. O teste ELISA com antígenos recombinantes apresentou medidas sumárias de sensibilidade e especificidade de 99,3% [97,9%-99,9%] e 97,5% [88,5%-99,5%], respectivamente. A heterogeneidade da PCR não foi explicada, porém foi detectado um efeito de ponto de corte. A sensibilidade sumária da PCR foi de 50% a 90%, e sua especificidade sumária foi de aproximadamente 100%. Há testes comerciais cujos relatórios técnicos não são acessíveis e por isso não foram incluídos nesta revisão. O segundo trabalho foi um estudo transversal com pacientes recrutados sequencialmente por estarem sob suspeita de serem portadores de doença de Chagas. Neste estudo foram incluídos 352 pacientes e a prevalência da doença de Chagas foi de 20,74%. Os preditores que compuseram o modelo final foram: referenciamento por banco de sangue, número de irmãos com doença de Chagas, presença de BRD 3 grau ao ECG, presença de EV isolada ao ECG, relato de ter residido em área rural no passado, presença de BDAS ao ECG, radiografia com sinal de cardiomegalia, ausência de hipertensão arterial, número de parentes com AVE, relato de ter habitado em vivenda de estuque/taipa no passado. Esse modelo apresentou uma área sob a curva ROC de 0,90. Um nomograma foi elaborado para estimativa individual de probabilidades de ser portador de doença de Chagas crônica.
64

Sensibilidade e especificidade do Sistema Manchester de Classificação de Risco na priorização de pacientes com infarto agudo do miocárdio que apresentam dor torácica / Sensitivity and specificity of Manchester Triage System in the prioritization of patients with acute myocardial infarction who present chest pain.

Fernanda Ayache Nishi 09 June 2017 (has links)
Introdução: O Sistema Manchester de Classificação de Risco tem como objetivo definir a prioridade clínica para atendimento médico de pacientes nos serviços de emergência. A avaliação de pacientes com suspeita de infarto agudo do miocárdio com sintomas típicos como a dor torácica realizada por meio do Sistema Manchester exige adequada sensibilidade e especificidade do sistema ao determinar a prioridade para atendimento médico. Objetivos: Os objetivos deste estudo foram integrar as melhores evidências disponíveis quanto a sensibilidade e especificidade do Sistema Manchester na classificação de pacientes com relação ao diagnóstico de síndrome coronariana aguda; estimar a sensibilidade e especificidade do Sistema Manchester na classificação de pacientes com dor torácica para a adequada priorização no que se refere ao diagnóstico de infarto agudo do miocárdio num hospital geral de ensino na cidade de São Paulo; e verificar associação entre o desempenho do Sistema Manchester na avaliação desses pacientes e variáveis selecionadas. Método: Este estudo foi desenvolvido em duas etapas, sendo a primeira uma revisão sistemática da literatura realizada segundo metodologia de revisões de acurácia de testes diagnósticos do Joanna Briggs Institute. Na segunda etapa do estudo foram estimadas a sensibilidade e a especificidade do Sistema Manchester na avaliação de pacientes com infarto agudo do miocárdio por meio de um estudo metodológico, transversal e retrospectivo. A sensibilidade e a especificidade do Sistema Manchester foram estimadas por meio da verificação da classificação estabelecida para pacientes com dor torácica que receberam ou não o diagnóstico médico de infarto agudo do miocárdio após a classificação. Resultados: Foram incluídos na revisão sistemática seis estudos com total de 54.176 participantes, todos de qualidade metodológica moderada, que apontaram valores de sensibilidade entre 70% e 80%. Dois estudos que apresentaram os dados necessários para o cálculo de especificidade, tiveram valores calculados de 59% e 97%. A amostra do estudo primário incluiu 10.087 episódios de classificação, sendo 52,3% de pacientes do sexo feminino com média de idade de 43,6 anos (DP=17,6). Do total de episódios, 139 tinham diagnóstico de infarto. A sensibilidade do Sistema Manchester foi de 44,6% e a especificidade foi de 91,3%. Houve associação estatisticamente significativa entre o desempenho do Sistema Manchester e a idade dos pacientes (p<0,001), com maior frequência de classificação incorreta nas faixas etárias mais altas. Não houve associação entre o sexo dos pacientes e o desempenho do Sistema Manchester. Conclusão: a recomendação para uso do Sistema Manchester na avaliação de pacientes no serviço de urgência em relação ao diagnóstico de síndrome coronariana aguda foi de grau B segundo graus de recomendação estabelecidos pelo Joanna Briggs Institute, o que remete a uma recomendação \"fraca\" para uma determinada estratégia de gestão da saúde. Essa conclusão decorre sobretudo da heterogeneidade dos critérios de inclusão e portanto das amostras dos estudos incluídos. Os resultados do estudo evidenciam a necessidade de se discutir formas de melhorar a sensibilidade desse sistema para a adequada priorização de pacientes com dor torácica. / Introduction: The Manchester Triage System aims to define the clinical priority of patients for medical care in the emergency department. The evaluation of patients with suspected acute myocardial infarction presenting typical symptoms such as chest pain using the Manchester Triage System requires proper sensitivity and specificity of the system in order to determine medical care priority. Objectives: The objectives of this study were: to integrate the best available evidence regarding the sensitivity and specificity of the Manchester Triage System in the evaluation of patients with the diagnose of acute coronary syndrome; to estimate the sensitivity and specificity of the Manchester Triage System in the classification of patients with chest pain to adequate prioritization in relation to the diagnose of acute myocardial infarction in a general teaching hospital in the city of São Paulo; to verify the association between the performance of the Manchester Triage System in the evaluation of these patients and selected variables. Methods: This study was developed in two stages, the first one consisted in a systematic review performed according to the methodology of diagnostic test accuracy systematic reviews from Joanna Briggs Institute. In the second stage of the study the sensitivity and specificity of the Manchester Triage System in the evaluation of patients with acute myocardial infarction were estimated though a methodological retrospective cross-sectional study. The sensitivity and specificity of the Manchester Triage System were estimated by verifying the classification of patients with chest pain who received or not the medical diagnosis of acute myocardial infarction. Results: The systematic review included six studies with a total of 54,176 participants, all of the studies with moderate methodological quality. The studies pointed sensitivity values from 70% to 80%. The specificity values calculated from two studies containing the necessary data were 59% and 97%. The sample of the performed primary study included 10,087 episodes of classification, 52.3% of the patients were females with average age of 43.58 years (SD=17.6). Of the total episodes, 139 had the diagnosis of infarction. The sensitivity of the Manchester Triage System was 44.6% and the specificity was 91.3%. There was statistically significant association between the performance of the Manchester Triage System and the age of the patients (p<0.001), with a higher frequency of incorrect classification in the older age groups. There was no observed association between the sex of the patients and the performance of the Manchester Triage System. Conclusion: Recommendation for the utilization of the Manchester Triage System in the evaluation of patients in emergency services to correct prioritization related to the diagnose of acute coronary syndrome was graded B according to the Joanna Briggs Institute grades of recommendation, which refers to a weak recommendation to a certain strategy for healthcare management. This finding is due to the heterogeneity of the inclusion criteria and therefore the samples of the included studies. The results of this study highlight the necessity of discussion about ways to improve the sensitivity of this system, for the adequate prioritization of patients with chest pain.
65

Contribuição para o diagnóstico da doença de Chagas crônica na prática clínica / Contribution to the diagnosis of chronic Chagas disease in clinical practice

Pedro Emmanuel Alvarenga Americano do Brasil 13 December 2010 (has links)
Em diferentes diretrizes para doença de Chagas crônica há diferentes algoritmos de execução de testes sorológicos. No entanto, há poucas referências quanto aos pacientes que devem ser submetidos à investigação sorológica, além dos indícios de que os testes ELISA possuem limitações e que o uso da PCR é controverso. Este trabalho contém resultados de dois estudos; o primeiro teve como objetivo rever a literatura sobre diagnóstico de doença de Chagas crônica e sumarizar a performance dos testes ELISA e PCR, e o segundo desenvolver um modelo de predição clínica para doença de Chagas crônica. O primeiro estudo foi uma revisão sistemática. Resumos relevantes foram procurados em bases remotas (MEDLINE, LILACS, EMBASE, SCOPUS, ISIWeb) e em bibliografia de textos completos. As investigações originais foram consideradas elegíveis para este trabalho quando estimassem sensibilidade e especificidade, ou confiabilidade (ou permitissem sua estimação) de testes ELISA ou PCR para o diagnóstico de doença de Chagas crônica. A heterogeneidade mostrou-se elevada em cada teste (ELISA e PCR) e o efeito de ponto de corte foi detectado em subgrupos. A sensibilidade e a especificidade sumárias do teste ELISA foram 97,7% [96,7%-98,5%] e 96,3% [94,6%-97,6%] respectivamente. O teste ELISA com antígenos recombinantes apresentou medidas sumárias de sensibilidade e especificidade de 99,3% [97,9%-99,9%] e 97,5% [88,5%-99,5%], respectivamente. A heterogeneidade da PCR não foi explicada, porém foi detectado um efeito de ponto de corte. A sensibilidade sumária da PCR foi de 50% a 90%, e sua especificidade sumária foi de aproximadamente 100%. Há testes comerciais cujos relatórios técnicos não são acessíveis e por isso não foram incluídos nesta revisão. O segundo trabalho foi um estudo transversal com pacientes recrutados sequencialmente por estarem sob suspeita de serem portadores de doença de Chagas. Neste estudo foram incluídos 352 pacientes e a prevalência da doença de Chagas foi de 20,74%. Os preditores que compuseram o modelo final foram: referenciamento por banco de sangue, número de irmãos com doença de Chagas, presença de BRD 3 grau ao ECG, presença de EV isolada ao ECG, relato de ter residido em área rural no passado, presença de BDAS ao ECG, radiografia com sinal de cardiomegalia, ausência de hipertensão arterial, número de parentes com AVE, relato de ter habitado em vivenda de estuque/taipa no passado. Esse modelo apresentou uma área sob a curva ROC de 0,90. Um nomograma foi elaborado para estimativa individual de probabilidades de ser portador de doença de Chagas crônica.
66

Comparação entre testes químico (o-toluidina) e imunoquímico de pesquisa de sangue oculto nas fezes e correlação com os achados colonoscópicos / Comparison between chemical (toluidine) and immunochemical faecal occult blood tests and correlation with the colonoscopic findings

Luana Vilarinho Borges 24 April 2013 (has links)
Introdução: O sangramento colorretal é considerado um sinal de alarme e não deve ser ignorado. A perda de sangue pode não ser identificada pelo paciente, o que caracteriza a presença de sangue oculto. Este diagnóstico pode ser confirmado por testes de Pesquisa de Sangue Oculto nas Fezes (PSOF), através de métodos químicos ou imunoquímicos de identificação da hemoglobina. O resultado positivo de um teste de PSOF requer investigação complementar com colonoscopia, exame invasivo, de alto custo e que exige preparo intestinal. Justifica-se, portanto, a aplicação de um teste diagnóstico mais sensível e específico. No presente estudo, foram avaliados quatro diferentes testes de PSOF em 176 pacientes submetidos à colonoscopia e seus resultados foram comparados. Objetivos: 1) avaliar o grau de concordância entre os testes de PSOF e a colonoscopia. 2) avaliar a sensibilidade, a especificidade e os valores de predição dos testes químico e imunoquímico de PSOF, em pacientes submetidos à colonoscopia. Métodos: Pacientes com indicação de realizar colonoscopia foram submetidos também à PSOF pelo método químico (o-toluidina) e pelo método imunoquímico, empregando três kits comerciais disponíveis no mercado. Os pacientes foram avaliados quanto à indicação do exame colonoscópico, resultado da colonoscopia e uso de alimentos e medicamentos que pudessem interferir no resultado dos testes fecais. Fundamentado nos achados endoscópicos, a colonoscopia foi categorizada em positiva ou negativa, de acordo com a possível fonte de sangramento colorretal. O grau de concordância entre os testes de PSOF foi avaliado pelo índice Kappa. Resultados: Dos 176 pacientes, houve predomínio do sexo feminino (64,8%), com média de idade de 55,5 anos. As indicações clínicas mais frequentes para realização de colonoscopia foram alteração do hábito intestinal, doença inflamatória intestinal, dor abdominal e anemia. Os principais achados foram pólipos < 1 cm, doença diverticular não complicada do cólon e exame normal. Quarenta e quatro (25%) colonoscopias foram categorizadas como positivas quanto à fonte de sangramento colorretal. Observou-se concordância (p<0,05) entre todos os testes avaliados e a colonoscopia. O teste da o-toluidina apresentou concordância pobre (Kappa 0,03), enquanto os demais testes apresentaram concordância moderada (Kappa entre 0,43-0,48). O teste da o-toluidina revelou menor sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo em comparação aos testes imunoquímicos. Conclusões: Os testes imunoquímicos apresentaram melhores índices de concordância com a colonoscopia, quando comparados ao teste da o-toluidina. Os testes imunoquímicos revelaram maior sensibilidade, especificidade e valores de predição na detecção de sangramento colorretal / Introduction: Colorectal bleeding is considered an alarm sign and should not be ignored. Blood loss can not be identified by the patient, which characterizes the presence of occult blood. This diagnosis can be confirmed by Faecal Occult Blood Testing (FOBT), through chemical or immunochemical methods. The positive outcome of a test requires complementary research FOBT with colonoscopy, an examination of invasive, costly and requires bowel preparation. It is justifiable, therefore, the application of diagnostic tests with better sensitivity and specificity. In the present study, we evaluated four different tests of PSOF in 176 patients undergoing colonoscopy and their results were compared. Objectives: 1) evaluate the degree of concordance between the PSOF tests and colonoscopy 2) assess the sensitivity, the specificity and the prediction values of the chemical and immunochemical FOBTs, in patients undergoing colonoscopy. Methods: Patients with indication of perform colonoscopy were subjected also to FOBT by the chemical method (toluidine test) and by the immunochemical method employing three commercial kits available in the market. Patients were evaluated regarding the indication of the colonoscopic examination, colonoscopy result, and use of foods and drugs that could interfere in the results of the faecal tests. Based on the endoscopic findings, the colonoscopy was rated as positive or negative, according to the possible colorectal bleeding source. The degree of accordance between FOBTs was evaluated by the Kappa index. Results: Among the 176 patients, there was a predominance of female gender (64.8%) with an average age of 55.5 years old. The most frequent clinical indication for colonoscopy were bowel habit changes, inflammatory bowel disease, abdominal pain and anemia. The main findings of colonoscopy were polyps <1 cm, uncomplicated colonic diverticular disease and normal exam. Forty-four (25%) colonoscopies were categorized as positive as to the possible source of colorectal bleeding. There was agreement (p<0.05) between all tests evaluated and the colonoscopy. The toluidine test presented poor accordance (Kappa 0.03), while the others showed moderate concordance (Kappa 0.43-0.48). The toluidine test showed less sensitivity, specificity, positive predictive value and negative predictive value compared to immunochemical tests. Conclusions: Immunochemical tests showed the best indexes of agreement with colonoscopy, when compared to the toluidine test. The immunochemical tests have shown greater sensitivity, specificity and predictive values in detecting colorectal bleeding
67

Sensibilidade e especificidade do auto-exame da mama em relaÃÃo ao seu exame clÃnico numa populaÃÃo de funcionÃrias de um hospital universitÃrio / Sensitivity and especificidade of the auto-examination of the breast in relation to its clinical examination in a population of employees of a university hospital

Francisco Alberto RÃgio de Oliveira 22 December 2004 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Objetivos: comparar os achados do auto-exame das mamas com o seu exame clÃnico no rastreamento de anormalidades mamÃrias. Verificar a freqÃÃncia dos conhecimentos e prÃticas relacionadas com o auto-exame das mamas. Estimar a sensibilidade e especificidade do auto-exame das mamas em relaÃÃo ao seu exame clÃnico. Averiguar se a sensibilidade à influenciada pelas variÃveis antropomÃtricas e sociodemogrÃficas ou pelos conhecimentos e prÃticas do auto-exame. Metodologia: estudo transversal de validaÃÃo de teste diagnÃstico, envolvendo 505 funcionÃrias de um hospital universitÃrio. Foi aplicado um questionÃrio sobre conhecimentos e prÃticas relacionadas com o auto-exame das mamas e ministrada instruÃÃo sobre o auto-exame a todas as participantes que posteriormente realizaram o auto-exame e foram submetidas a exame clÃnico por Ãnico examinador. Os intervalos de confianÃa de 95% foram calculados pelo mÃtodo de aproximaÃÃo pela distribuiÃÃo normal. ProporÃÃes foram comparadas por meio do teste do qui-quadrado e foram consideradas significativamente diferentes (teste bicaudado) quando a probabilidade de estas serem semelhantes foi menor ou igual a 0,05. Resultados: 94,06% tinham recebido informaÃÃo sobre o auto-exame, 29,90% pelo mÃdico. 32,28% realizavam o auto-exame mensalmente, 55,95% apÃs a menstruaÃÃo e o procedimento mais realizado era a palpaÃÃo durante o banho. A sensibilidade para qualquer achado foi de 37,21 % com IC 95% de 32,77%-41,82%. A sensibilidade, excluindo-se a assimetria, foi de 44,85% com IC 95% de 39,59-50,26%. A sensibilidade exclusiva para nÃdulo e espessamento (massa) foi de 52,07% com IC 95% de 43, 17%-60,87%. A especificidade para qualquer achado foi de 71,64% com IC 95% de 60,00%Â81,44%. A especificidade, excluindo-se a assimetria, foi de 80,57% com IC 95% de 74,20%-85,93%. A especificidade exclusiva para massa foi de 90,10% com IC 95% de 86,81 %-92,79%. A sensibilidade nÃo mostrou diferenÃa estatisticamente significativa quando estratificada por mama, conhecimentos e prÃticas relacionadas ao exame feito pela prÃpria e variÃveis antropomÃtricas e sociodemogrÃficas. ConclusÃo: o auto-exame à bastante conhecido por essa populaÃÃo, apresenta em relaÃÃo ao exame clÃnico uma baixa sensibilidade e especificidade, que se eleva quando analisadas exclusivamente as massas, aproximando-se da sensibilidade e especificidade da mamografia em mulheres abaixo dos 40 anos de idade
68

Respondent driven sampling (RDS) aplicado à populaÃÃo de homens que fazem sexo com homens no Brasil / Respondent driven sampling (RDS) applied to the population of men who have sex with men in Brazil

Rosa Maria Salani Mota 02 April 2012 (has links)
Os estimadores para parÃmetros populacionais em amostras coletadas pelo mÃtodo de amostragem Respondent Driven Sampling (RDS) sÃo sensÃveis à presenÃa de observaÃÃes ignoradas e tendem a subestimar os parÃmetros populacionais. A ausÃncia de um quadro de amostragem bem definido para a coleta de amostras em populaÃÃes consideradas escondidas e/ou de acesso difÃcil fez com que o RDS se tornasse uma importante ferramenta de vigilÃncia comportamental e biolÃgica nessas populaÃÃes com maior risco para o HIV, em especial no Brasil. Considerado um mÃtodo de amostragem em cadeia de referÃncia, o RDS utiliza informaÃÃes sobre as conexÃes das redes sociais para obter estimadores contingentes assintoticamente imparciais das caracterÃsticas populacionais e a precisÃo desses estimadores. Estudo multicÃntrico de corte transversal para vigilÃncia epidemiolÃgica e comportamental em populaÃÃes de HSH com 18 anos ou mais foi realizado em dez cidades brasileiras (Manaus, Recife, Salvador, Campo Grande, BrasÃlia, Curitiba, ItajaÃ, Santos, Belo Horizonte e Rio de Janeiro) no ano de 2009 e, coleta, em cada municÃpio, uma amostra pelo RDS. Neste estudo, foi oferecido o teste rÃpido para diagnÃstico da infecÃÃo por HIV Ãqueles que aceitam participar de um prÃ-aconselhamento. Todos os participantes foram inquiridos sobre a realizaÃÃo de testes anti-HIV anteriores ao da pesquisa e sobre qual o diagnÃstico obtido. Com a simulaÃÃo de uma variÃvel dicotÃmica (exemplo: sorologia para HIV positiva ou negativa) sem observaÃÃes ignoradas na rede de recrutamento do Rio de Janeiro e posteriores exclusÃes de 18 recrutados, encontra-se que, a amostra com ignorados à avaliada com base em um nÃmero de observaÃÃes significativamente menor que o da amostra original e o parÃmetro em questÃo (prevalÃncia do HIV) à subestimado. Ainda, com a imputaÃÃo Ãnica das sorologias ignoradas, no contexto descritivo, observam-se, nas amostras com imputaÃÃo, marcadores biolÃgicos que indicam valores mais acurados. No estudo multicÃntrico, para o grupo de participantes que autorrelatou sorologia positiva ou negativa para o HIV e realizou teste rÃpido na pesquisa, observa-se para os autorrelatos elevada concordÃncia (0,88) e sensibilidade de 100% com o padrÃo-ouro teste rÃpido para diagnÃstico do HIV. Finalmente, estimando a prevalÃncia para o HIV nas amostras observadas por municÃpio e geral, e, com a proposta da imputaÃÃo pelo autorrelato do HIV positivo e posterior atribuiÃÃo de sorologia HIV +/- mediante trÃs propostas de imputaÃÃes: todos sÃo negativos, proximidade dos participantes na rede de recrutamento e pela regressÃo logÃstica. Encontra-se nas amostras coletadas a estimativa geral da prevalÃncia do HIV igual a 11,1% sendo, por municÃpio, a menor prevalÃncia em Santos (2,6%) e a maior no Rio de Janeiro (17,6%). Com as imputaÃÃes as prevalÃncias tendem a aumentar e as maiores estimativas sÃo encontradas com a imputaÃÃo por meio da regressÃo logÃstica em sete de nove municÃpios avaliados por essa metodologia. A estimativa geral do HIV pela regressÃo logÃstica à 14,2% sendo, por municÃpio, a menor prevalÃncia no Recife (5,2%) e a maior em BrasÃlia (23,7%). A imputaÃÃo da sorologia de infecÃÃo por HIV pela regressÃo logÃstica ocorre por municÃpio e por intermÃdio de um modelo com acurÃcia mÃnima igual a 70%. / The estimators for population parameters in samples collected by sampling Respondent Driven Sampling (RDS) are sensitive to the presence of observations ignored and tends to underestimate the population parameters. The absence of a clearly defined sampling frame for the collection of samples from populations considered hidden and/or difficult access made the RDS became an important tool for biological and behavioral surveillance in these populations at higher risk for HIV, especially Brazil. Considered a method of sampling in the reference chain, RDS uses information about the connections of social networks for specific asymptotically unbiased estimators of population characteristics and accuracy of these estimators. Multicenter cross-sectional epidemiological and behavioral surveillance for MSM populations in 18 years or more was conducted in 10 cities (Manaus, Recife, Salvador, Campo Grande, Brasilia, Curitiba, ItajaÃ, Santos, Belo Horizonte and Rio de Janeiro) in 2009 and collected in each municipality, a sample through RDS. This study offered the rapid test for diagnosis of HIV infection to those who agreed to participate in a pre-counseling. All participants were asked about testing for HIV prior to the research and about which the diagnosis obtained. By simulating a dichotomous variable (eg, HIV serology positive or negative) without comment ignored in recruiting network in Rio de Janeiro and later recruited 18 deletions, that is, the unknown sample is evaluated from a number of observations significantly smaller than the original sample and the parameter in question (HIV prevalence) is underestimated. Still, with the allocation of single serology ignored in the descriptive context, it is observed in samples with attribution, biological markers indicating that more accurate values. Multicentre study for the group of participants who self-reported positive or negative serology for HIV rapid test and performed the research notes to self-reports, high correlation (0.88) and 100% sensitivity with gold standard rapid test for HIV diagnosis. Finally, estimating the prevalence of HIV in the samples observed by county and general, and the proposed allocation of the self-reported HIV positive and HIV serology subsequent assignment of + / - through three proposed charges: are all negative, proximity of the participants in the network recruitment and by logistic regression. It is found in samples collected from the estimated overall HIV prevalence was equal to 11.1%, by municipality, the lower prevalence in Santos (2.6%) and highest in Rio de Janeiro (17.6%).With the charges tend to increase the prevalence and the highest estimates are found with the imputation logistic regression in 7 of 9 municipalities assessed by this methodology. The estimated overall HIV logistic regression is 14.2% and, by municipality, the lower prevalence in Recife (5.2%) and highest in Brasilia (23.7%). The allocation of serology for HIV by the Logistic Regression occurs by municipality and by a model with a minimum accuracy of 70%.
69

Acurária do estudo dos jatos ureterais à ultra-sonografia do Doppler Colorido no diagnóstico das hidronefroses / Diagnostic accuracy of color Doppler sonographic study of the ureteric jets in evaluation of hydronephrosis

José de Bessa Junior 10 August 2007 (has links)
Introdução e Objetivo: Hidronefrose e Obstrução são condições associadas, entretanto dilatações da via excretora podem ocorrer na ausência de obstruções clinicamente importantes. Ultra-sonografia convencional e Renograma com Diuréticos são os métodos diagnósticos complementares mais utilizados na avaliação das hidronefroses na infância. Recentes trabalhos têm demonstrado a possibilidade de observarmos os jatos ureterais com o Estudo Ultra-sonográfico com Doppler Colorido e sugerido a sua aplicação no diagnóstico diferencial das hidronefroses. O objetivo do presente trabalho foi avaliar a aplicabilidade do estudo dos jatos ureterais como método diagnóstico na identificação das hidronefroses obstrutivas e não obstrutivas na população pediátrica. Métodos: Foram estudadas 48 crianças (35 meninos e 13 meninas) com idade que variou de um mês a 14 anos (mediana de 4 anos), que se apresentaram com Hidronefroses Unilaterais, Graus III e IV, e com suspeita de obstrução da junção pieloureteral. Todos os sujeitos foram submetidos ao Estudo dos jatos ureterais e ao Renograma com Diuréticos num período de duas semanas. As unidades hidronefróticas foram consideradas obstruídas quando a Função Renal Diferencial era menor do que 40%, ou em indivíduos mais velhos que apresentavam dor lombar intermitente. Os jatos ureterais de cada meato foram contados por um período de 5 minutos e considerados separadamente. Freqüência Relativa dos Jatos (FRJ) foi definida como o numero de jatos ureterais no lado afetado dividido pela soma dos jatos ureterais observados bilateralmente. Resultados: Vinte e duas (45,8%) unidades hidronefróticas foram consideradas obstruídas.A média da FRJ diferiu significativamente entre as hidronefroses obstrutivas (0,09 ± 0,15) e não obstrutivas (0,41 ± 0,11). (p<0.001). Análise da Curva ROC revelou que FRJ < 0,25 é o melhor valor que distingue as hidronefroses obstrutivas e não obstrutivas e o faz corretamente em 91,2 % dos casos, com uma Sensibilidade de 86,4% (IC95%=78,6-98,2%) e Especificidade de of 96.15% (IC95%=87.8-99%). O Índice de Probabilidade Positivo foi de 22,45 e a Razão de Chances Diagnóstica de 158,3. A área sob a curva ROC foi de 0,91 (IC95%=0,86-0,98) indicando a excelente acurácia do método. Conclusões: FRJ < 25 % mostrou ser um bom indicador de obstrução nas hidronefroses unilaterais da infância. O estudo dos jatos ureterais a Ultrasonografia com Doppler Colorido é método simples, não invasivo e pode ser utilizado na abordagem inicial e no seguimento, na diferenciação das hidronefroses obstrutivas e não obstrutivas na população pediátrica / Introduction and Objective: Hydronephrosis (HN) and obstruction are closely associated, but upper urinary tract dilatation can occur without significant obstruction. Despite some pitfalls, conventional ultrasonography and diuretic renography (DR) are the main modalities in the evaluation of HN in children. Recent reports have demonstrated the usefulness of Color Doppler Ultrasonography (CDUS) as a reliable method to identify the ureteric jets (UJ) in the bladder. The aim of this study was to evaluate CDUS evaluation of the UJ in the bladder as a diagnostic tool to distinguish obstructive from non-obstructive dilatations of the upper tract in pediatric population. Methods: We evaluated 48 patients (35 boys and 13 girls), aged 1 month to 14 years (median = 4 ys.), who presented with unilateral grade III and IV hydronephrosis suspicious of pyeloureteral junction obstruction. All patients underwent DR and evaluation of UJ by transverse CDSG of the bladder within a maximum of 2 weeks. Obstruction was considered in the DR when the hydronephrotic unit showed Differential Renal Function of less than 40%, or when symptomatic intermittent renal colic was present in older children. The number of UJ was counted over a 5 min period and its frequency was calculated for each ureteral orifice. Relative Jet Frequency (RJF) was defined as the UJ frequency of hydronephrotic side divided by total UJ frequency. Receiver-Operating Characteristic (ROC) plots were constructed to determine the best cuttoff for RJF, in order to identify renal units with obstructive hydronephrosis. Results:Twenty-two(45.8%) hydronephrotic units were considered obstructed. The mean RJF differed significantly between obstructive (0.09 ± 0,15) and non-obstructive hydronephrosis (0.41± 0.11)(p<0.001). ROC analysis revealed that RJF< 0.25 was the best threshold and it correctly discriminates obstruction in 91.2% of the childrens with a sensitivity of 86.4% (95%CI=78.6-98.2%) and specificity of 96.15% (95%CI=87,8-99%). The Positive Likelihood Ratio was 22.45 and Diagnostic Odds Ratio was 158.3.The area under the ROC curve was 0.91 (95%CI=0.86-0.98), indicating excellent discrimination power. Conclusions: In this study RJF < 25% was found to be a good indicator of obstruction in children with unilateral hydronephrosis. CDUS evaluation of UJ is an easy and non-invasive method that can be used as an initial diagnostic tool and in follow-up cases, to differentiate obstructed from non-obstructed hydronephrosis in the pediatric population
70

Colangiopancreatografia retrógrada endoscópica versus ultrassom endoscópico no diagnóstico histológico da estenose biliar maligna: revisão sistemática e metanálise / ERCP versus EUS for tissue diagnosis of malignant biliary stricture: systematic review and meta-analysis

Diogo Turiani Hourneaux de Moura 07 March 2016 (has links)
Introdução: O diagnóstico histológico das estenoses biliares é fundamental na definição da terapêutica a ser empregada, devido à heterogeneidade dos resultados dos estudos comparando o uso do escovado citológico e da biópsia transpapilar na colangiopancreatografia retrógada endoscópica (CPRE) com a punção aspirativa ecoguiada com agulha fina (ECO-PAAF) no diagnóstico histológico da estenose biliar maligna, e o fato de não existirem revisões sistemáticas e metanálises comparando esses métodos, este estudo propõe comparar esses dois métodos no diagnóstico histológico da estenose biliar maligna, através de revisão sistemática e metanálise da literatura. Métodos: Utilizando as bases de dados eletrônicas Medline, Embase, Cochrane, LILACS, CINAHL, e Scopus foram pesquisados estudos datados anteriormente a novembro de 2014. De um total de 1009 estudos publicados, foram selecionados três estudos prospectivos comparando ECO-PAAF e CPRE no diagnóstico histológico da estenose biliar maligna e cinco estudos transversais comparando ECO-PAAF com o mesmo padrão-ouro dos outros três estudos comparativos. Todos os pacientes foram submetidos ao mesmo padrão-ouro. Foram calculadas as variáveis do estudo (prevalência, sensibilidade, especificidade, valores preditivos positivos e negativos e acurácia) e realizada a metanálise utilizando os softwares Rev Man 5 e Meta-DiSc 1.4. Resultados: Um total de 294 pacientes foi incluído na análise. A probabilidade pré-teste para estenose biliar maligna foi de 76,66%. As sensibilidades médias da CPRE e da ECO-PAAF para o diagnóstico histológico da estenose biliar maligna foram de 49% e 76,5%, respectivamente; especificidades foram de 96,33% e 100%, respectivamente. As probabilidades pós-teste também foram determinadas: valores preditivos positivos de 98,33% e 100%, respectivamente, e valores preditivos negativos de 34% e 58,87%. As acurácias foram 60,66% e 82,25%, respectivamente. Conclusão: A ECO-PAAF é superior a CPRE com escovado citológico e/ou biópsia transpapilar no diagnóstico histológico da estenose biliar maligna. No entanto, um teste de ECO-PAAF ou CPRE com amostra histológica negativa não pode excluir a estenose biliar maligna, pois ambos os testes apresentam baixo valor preditivo negativo / Background and Aims: Due the heterogeneity of the results of studies comparing the use of ERCP-based brush cytology and forceps biopsy and EUS-guided fine-needle aspiration for the diagnosis of malignant biliary stricture, and the fact that there are no systematic reviews and meta-analysis comparing these methods, in this review, we will compare ERCP against EUS-FNA for tissue diagnosis of malignant biliary stricture. Design: A systematic review of comparative studies (prospective or retrospective) was conducted analyzing EUS and ERCP for tissue diagnosis of malignant biliary stricture. Methods: The databases Medline, EMBASE, Cochrane, LILACS, CINAHL, and Scopus were searched for studies dated previous to November 2014. We identified three prospective studies comparing EUS-FNA and ERCP for the diagnosis of malignant biliary stricture and five cross sectional studies comparing EUS-FNA with the same gold standard of the other three studies. All patients were submitted to the same gold standard method. We calculated study variables (prevalence, sensitivity, specificity, positive and negative predictive values, and accuracy) and performed a meta-analysis using the Rev Man 5 and Meta-DiSc 1.4 softwares. Results: A total of 294 patients were included in the analysis. The pretest probability for malignant biliary stricture was 76.66%. The mean sensitivities of ERCP and EUS-FNA for tissue diagnosis of malignant biliary stricture were 49% and 76.5%, respectively; specificities were 96.33% and 100%, respectively. The post-test probabilities, positive predictive value (98.33% and 100%, respectively) and negative predictive value (34% and 58.87%, respectively) were determined. The accuracies were 60.66% and 82.25%, respectively. Conclusion: EUS- FNA is superior to ERCP with brush cytology and forceps biopsy for diagnosing malignant biliary strictures. However, a negative EUS-FNA or ERCP test may not exclude malignant biliary stricture because both have low negative post-test probabilities

Page generated in 0.0383 seconds