• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • 14
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 88
  • 88
  • 76
  • 41
  • 38
  • 33
  • 20
  • 19
  • 18
  • 15
  • 15
  • 14
  • 13
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Resistência de união entre cimentos resinosos e zircônia / Bond strenght between resin cements and zirconia

Valdivia, Juan Rommel Medina 18 August 2011 (has links)
Este estudo avaliou a resistência de união de cimentos resinosos à zircônia tetragonal parcialmente estabilizada com ítrio (NobelProceraTM Zircônia) submetida a tratamentos superficiais mecânicos e químicos. Os cimentos utilizados foram o cimento resinoso auto-condicionante de polimerização química Multilink (Ivoclar Vivadent) associado ao Metal/Zirconia Primer (Ivoclar Vivadent) e o cimento resinoso auto-adesivo de polimerização química e dual RelyX U100 (3M-ESPE) associado ao adesivo Adper Single Bond Plus 2 (3M-ESPE). Utilizando 40 cilindros de zircônia (diâmetro de 3,5 mm) foram realizados 120 ensaios (n=40 para cada cimento). Para cada cimento os cilindros foram divididos em 4 grupos (n=10) em função do tratamento superficial avaliado: 1- sem tratamento; 2- agente de união (primer ou adesivo); 3- jateamento com oxido de alumínio 50µm; 4- associação do jateamento e o agente de união. A aplicação do cimento resinoso foi realizada utilizando uma matriz de teflon com orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Após a aplicação de cada cimento nas 4 condições de superficie, os espécimes foram armazenados em água deionizada a 37ºC durante 24h e submetidos ao teste de resistência ao cisalhamento. Os resultados foram analisados com ANOVA a dois critérios e teste de Tukey (p<0,05). Sem tratamento superficial o RelyX U100 químico (5,52 Mpa) e dual (6,53 Mpa) tiveram melhor comportamento que o cimento Multilink (0,76). A associação do jateamento e o agente de união melhorou os valores de resistência de união para o cimento Multilink (7,68 Mpa) e para o cimento RelyX U100 dual (10,26 Mpa), sendo este último superior a todos os outros grupos. A associação do Adper Single Bond Plus 2 e o RelyX U100 sem jateamento, deve ser evitado. / The aim of this study was to evaluate the shear bond strength of resin cements to the yttria stabilized tetragonal zirconia (NobelProceraTM Zirconia) subjected to mechanical and chemical surface treatments. The cements used were: a self-etching resin cement with chemical polymerization Multilink (Ivoclar - Vivadent) associated to the Metal / Zirconia Primer (Ivoclar - Vivadent) and self-adhesive resin cement with chemical and dual polymerization RelyX U100 (3M-ESPE) associated to the adhesive Single Bond Plus Adper 2 (3M-ESPE). Using 40 cylinders of zirconia (3.5 mm diameter) were performed 120 trials (n = 40 for each cement). For each cement, cylinders were divided into four groups (n = 10) based on the surface treatment rated: 1 - untreated, 2 - bonding agent (primer or adhesive) 3 air abrasion with 50µm aluminum oxide, 4 - combination of air abrasion and bonding agent. The application of resin cement was performed using a teflon matrix with a central hole 3.5 mm in diameter and 3.0 mm deep. After application of each cement in the four surface conditions, the specimens were stored in deionized water at 37 ° C for 24 hours and tested for shear bond strength. Results were analyzed with an ANOVA Two Criteria and Tukey\'s test (p <0.05). Without surface treatment, chemical RelyX U100 (5.52 MPa) and dual (6.53 MPa) had better behavior than Multilink Cement (0.76). The combination of air abrasion and bonding agent improved the bond strength values for Multilink (7.68 MPa) and for RelyX U100 dual (10.26 MPa), this one superior to all other groups. The association of Adper Single Bond 2 and RelyX U100 Plus without air abrasion, should be contraindicated.
22

Avaliação da resistência ao Cisalhamento de braquetes novos recolocados com diferentes resinas ortodônticas / Evaluation of shear bond strength of new metallic brackets rebounded with different orthodontic resins

Jimenez, Emigdio Enrique Orellana 04 December 2007 (has links)
Made available in DSpace on 2017-07-24T19:22:06Z (GMT). No. of bitstreams: 1 Emigdio Enrique Orellana Jimenez.pdf: 1399808 bytes, checksum: 9a5dfb23c60c52032fb9609d09fd87ca (MD5) Previous issue date: 2007-12-04 / The present study evaluated in vitro the shear bond strength of new bonded and rebounded metallic brackets with three orthodontic composites. Ninety extracted first superior premolars were randomly divided in three groups, according to the different tested composite. All bonding procedures followed the manufacturer’s specifications with a 300g standard pressure over the bracket during positioning. Alpha plast (AP), Concise (CO) and Transbond XT (TB) were the evaluated composites. For each group, three shear bond strength examinations were performed in three different times, initial (T0), first rebonding (T1) and second rebonding (T2), with a 24 hour interval between them. The tests were performed with a SHIMADZU AG-I, (10KN) machine with a 0,5 mm/min cross-head speed and the fracture strength was recorded in Megapscal (MPa) considering brackets base area. The mean shear bond strength was evaluated and the adhesive remnant index (ARI) was scored. The results showed that in T0 the groups AP and CO presented similar and higher values than TB, in T1 and T2 the highest shear bond strength values were found in group AP, followed by group CO and TB. Those data were submitted to two-way ANOVA and Tukey´s and Bonferroni´s test (p<0,05) and the ARI results were analyzed by the Kruskal Wallis test followed by the Dunn´s test. It was found a statistical significant difference (p<0,05) in shear bond strength between groups but not between the different bonding and rebonding times. The highest shear bond strength values were observed in the group AP, followed by CO and TB. In relation to ARI, it was noticed a significant statistical difference (p<0,05) between the groups, and the TB presented higher values (p<0,05) than those verified in AP and CO, for T0 and T2. It was concluded that repeated bondings with new brackets presented an adhesive difference in shear bond strength considering the utilized composite, however, at bonding and rebonding with the same composite, there are no significant differences. / Este estudo avaliou in vitro a resistência ao cisalhamento de braquetes metálicos novos colados e recolados com três resinas ortodônticas. Foram utilizados 90 primeiros pré-molares superiores humanos extraídos para a confecção dos corpos de prova, os quais foram divididos aleatoriamente em três grupos;(n = 30) de acordo com a resina utilizada. Todos os procedimentos de colagem seguiram as recomendações do fabricante com uma pressão padronizada em 300g. Foram utilizadas as resinas Alpha Plast (AP), Concise (CO) e Transbond XT (TB). Para cada um dos grupos foram realizados três ensaios de cisalhamento em três tempos, um inicial (T0) e os outros dois T1 e T2, primeira e segunda recolagens, respectivamente, com intervalos de 24 horas. Os testes de cisalhamento foram realizados em uma máquina eletrônica de ensaios eletromecânicos SHIMADZU AG-I, (10KN), com velocidade de pressão de 0,5mm/min e carga de ruptura registrada em Megapascal (MPa). Considerando a área da base do braquete, foram mensuradas as resistências médias ao cisalhamento e o índice de adesivo remanescente (IAR). Os resultados demonstraram que para T0 os grupos AP e CO apresentaram valores próximos e superiores a TB, para T1 e T2 os maiores valores de resistência foram observados para o grupo AP, seguido dos grupos CO e TB. Estes dados foram submetidos à ANOVA 2 critérios e ao teste de Tukey e de Bonferroni (p<0,05) e para o IAR o teste Kruskal Wallis, seguido de teste Dunn. Existe diferença estatística significante (p<0,05) na resistência ao cisalhamento (MPa) entre os grupos mas não entre os tempos de colagem e recolagem de braquetes novos, sendo que os maiores valores de resistência ao cisalhamento foram encontrados no grupo AP, seguido de CO e TB. Em relação ao IAR, existiu diferença estatisticamente significante (p<0,05) entre os grupos, o grupo TB foi estatisticamente superior (p<0,05) aos grupos AP e CO, para o T0 e T2. Concluiu-se que colagens repetidas com braquetes novos apresentam diferença adesiva de resistência ao cisalhamento considerando a resina utilizada, porém na colagem e recolagens com a mesma resina não há diferenças significativas.
23

Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadas

Rastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5) Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets bonded with fluoride-releasing composite resins, and to compare them to a conventional resin. For this study, sixty premolars extracted due to orthodontic reasons were used, which were divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at 37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the specimens were submitted to the shear bond strength test, in occluso-gingival direction, in Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis, Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20 MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the averages of the three groups were significantly different among themselves (p<0.05), with the highest resistance for the Concise Group and the lowest for the Ultrabond Group. However, all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M), Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ± 6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de 16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001). O teste de Tukey evidenciou que as médias dos três grupos foram significativamente diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva adequada para uso clínico.
24

An in-vitro study of the physical properties of core build-up materials

Asia, Winifred January 2017 (has links)
Magister Chirurgiae Dentium - MChD (Prosthodontics) / The aim of this study was to evaluate and compare the physical properties of two core build-up materials (ParaCore and CoreXflow) and compare this to conventional composite material (Filtek Supreme Plus and SDR Flow) used as core build-up material.
25

Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinoso /

Ribeiro, João Gustavo Rabelo. January 2005 (has links)
Orientador: José Cláudio Martins Segalla / Banca: Regina Helena Barbosa Tavares da Silva / Banca: Marcos Ribeiro Moysés / Resumo: O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de "a" e "b". As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) "a" and "b" treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values. / Mestre
26

Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinoso

Ribeiro, João Gustavo Rabelo [UNESP] 03 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-03Bitstream added on 2014-06-13T19:16:51Z : No. of bitstreams: 1 ribeiro_jgr_me_arafo.pdf: 3291389 bytes, checksum: 7433b8057e44c506b548538c7a3e997e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de a e b. As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos... / The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) a and b treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values.
27

Resistência de união de cimentos resinosos, ao cisalhamento, variando o substrato e o material restaurador

Ariki, Eurípedes Kaizo [UNESP] 19 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-19Bitstream added on 2014-06-13T20:58:49Z : No. of bitstreams: 1 ariki_ek_me_sjc.pdf: 497007 bytes, checksum: 903e217ecb5b3b29845a544edd5e4640 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a resistência de união ao cisalhamento de três diferentes tipos de agentes cimentantes: auto-condicionante (Panavia F / P), convencional (RelyX ARC - R) e auto-adesivo (RelyX U100 - U), usando dois tipos de substratos (esmalte / E e dentina / D) e dois tipos de materiais restauradores (cerâmica - C e resina composta laboratorial - R). Foram utilizados cento e vinte incisivos bovinos incluídos em resina acrílica, de modo que uma parte da face vestibular ficasse exposta. Os dentes foram desgastados até se obter uma área lisa e plana, de aproximadamente de 25 mm2, em metade dos espécimes foi exposto esmalte, na outra metade dentina. Uma fita adesiva com um orifício no centro com 3 mm de diâmetro foi colada sobre estas áreas, delimitando a área a ser usada no teste. Foram confeccionados sessenta cilindros de cerâmica a base de dissilicato de lítio (IPS e.max) e sessenta cilindros de resina composta (SR Adoro) com dimensões de 3mm de diâmetro e 3mm de altura. Os cilindros foram cimentados aos substratos com os três tipos de cimento resinoso, formando doze grupos experimentais: G1(PEC); G2(PER); G3(PDC); G4(PDR); G5(REC), G6(RER); G7(RDC); G8(RDR): G9(UEC); G10(UER); G11(UDC) e G12(UDR). Após um período de uma semana, os corpos-de-prova foram levados à máquina de ensaios universais para a realização do teste de cisalhamento com velocidade de 0,5 mm/min. Os resultados (foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey em nível de 5% de significância. Verificou-se que o maior valor médio obtido foi do G5 (17,46 MPa) diferindo significativamente dos demais grupos, exceto do G1 (14,60 MPa). O G12 (1,03 MPa) apresentou o menor valor de resistência, não apresentando semelhança estatística com os outros grupos. A adesão em esmalte... / The aim of the present study was to evaluate the shear bond strength of three types of luting agents: self-etching (Panavia F, P), conventional (Rely X ARC, R) and self-adhesive (Rely X U100, U), using enamel (E) or dentin (D) as substrates and two types of restorative materials (ceramic, C and laboratorial composite, R). One hundred and twenty-five bovine incisors were embedded in acrylic resin leaving their bucal side exposed. The teeth were ground flat until a 5mm2 area was created. Half of the specimens had enamel exposed and the other half had dentin exposed. A piece of tape with a 3 mm hole was used to delimitate the bonding area. Sixty cylinders of ceramic (IPS E.max Press) and sixty of composite (SR Adoro), 3 mm in diameter and 3 mm in height, were confectioned. The cylinders were luted to the substrates, forming twelve groups: G1 (PEC); G2 (PER); G3 (PDC); G4 (PDR); G5 (REC), G6 (RER); G7 (RDC); G8(RDR): G9 (UEC); G10(UER); G11(UDC) and G12(UDR). After one week, the specimens were subjected to a shear test in a universal testing machine at a crosshead speed of 0,5 mm/min. The results were submitted to both the Anova and Tukey tests (p<0.05) for statistical analysis. It was observed that the mean of G5 (17,46 MPa) was significantly different from the other groups means, except for G1 (14,60 MPa). Statistically G12 (1,03) had the lowest bond strength differing from the other groups. Bondings between was ceramic and enamel determined the highest bond strength for all luting agents. Due to the low bond strength and the failures between cement and substrate, using the self-adhesive cement and laboratorial composite to make bonds is not advisable.
28

Avaliação da resistência adesiva e da atividade antimicrobiana de diferentes sistemas de colagem de bráquetes associados à clorexidina e ao flúor

Ribeiro, Jorge Luís de Oliveira January 2006 (has links)
121f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:12:49Z No. of bitstreams: 2 Dissertacao Jorge Ribeiro2.pdf: 5452461 bytes, checksum: 42c5f38b042e314e1265214af3e8f68c (MD5) Dissertacao Jorge Ribeiro1.pdf: 51427 bytes, checksum: 32ae2c485acbca7fce04dfdc7745eaf0 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:02:53Z (GMT) No. of bitstreams: 2 Dissertacao Jorge Ribeiro2.pdf: 5452461 bytes, checksum: 42c5f38b042e314e1265214af3e8f68c (MD5) Dissertacao Jorge Ribeiro1.pdf: 51427 bytes, checksum: 32ae2c485acbca7fce04dfdc7745eaf0 (MD5) / Made available in DSpace on 2013-05-08T12:02:54Z (GMT). No. of bitstreams: 2 Dissertacao Jorge Ribeiro2.pdf: 5452461 bytes, checksum: 42c5f38b042e314e1265214af3e8f68c (MD5) Dissertacao Jorge Ribeiro1.pdf: 51427 bytes, checksum: 32ae2c485acbca7fce04dfdc7745eaf0 (MD5) Previous issue date: 2006 / O objetivo deste estudo in vitro foi avaliar a influência da incorporação de clorexidina e flúor na resistência adesiva e na atividade antimicrobiana de diferentes sistemas de colagem de bráquetes (Sistema Transbond XT / 3M-Unitek e Sistema Enlight / Ormco) cujos respectivos adesivos foram pré misturados ao verniz de flúor (Fluor Protector / Ivoclar- Vivadent) e/ou verniz de clorexidina (Cervitec / Ivoclar-Vivadent). A amostra utilizada foi constituída por pré-molares humanos, extraídos por indicações ortodônticas e divididos em oito grupos experimentais: G1 – Sistema Transbond XT conforme prescrito pelo fabricante; G2 – Sistema Transbond XT associado a verniz de clorexidina; G3 – Sistema Transbond XT associado a verniz de flúor; G4 – Sistema Transbond XT associado, simultaneamente, aos vernizes de clorexidina e flúor; G5 – Sistema Enlight conforme prescrito pelo fabricante; G6 - Sistema Enlight associado a verniz de clorexidina; G7 - Sistema Enlight associado a verniz de flúor; G8 - Sistema Enlight associado, simultaneamente, aos vernizes de clorexidina e flúor. A avaliação da resistência adesiva foi realizada pelo teste de cisalhamento; também foi realizada a observação do Índice de Adesivo Remanescente (IAR) na superfície do esmalte dental, após a descolagem dos bráquetes. Além disso, os corpos-de-prova foram submetidos à ciclagem de pH, visando simular desafio cariogênico e, também foram incluídos em meios de cultura contendo Staphylococcus aureus, a fim de avaliar a possibilidade desses sistemas de colagem, associados a flúor e/ou clorexidina, proporcionarem proteção à desmineralização do esmalte dental e/ou impedirem o crescimento bacteriano, sobretudo nas áreas localizadas ao redor dos bráquetes. A partir dos resultados obtidos pôde-se concluir que a resistência adesiva não foi alterada, de forma estatisticamente significante, nos grupos experimentais que utilizaram o sistema Transbond XT (G2, G3 e G4), bem como, no grupo que utilizou o sistema Enlight associado ao verniz de clorexidina (G6); já nos grupos que utilizaram o sistema Enlight associado ao verniz de flúor isoladamente (G7) e/ou simultaneamente ao verniz de clorexidina (G8), as resistências adesivas foram reduzidas de forma estatisticamente significante, quando comparados ao respectivo grupo controle (G5). A avaliação do Índice de Adesivo Remanescente (IAR) demonstrou predominância do “escore 3” em todos os grupos experimentais que utilizaram o Sistema Transbond XT e do “escore 2” para todos os grupos experimentais que utilizaram o Sistema Enlight e, portanto, fraturas adesivas na interface adesivo-bráquete e fraturas mistas (adesiva e coesiva), respectivamente. Além disso, observando-se a formação de halos de inibição de crescimento bacteriano nos meios de cultura, 24 horas após a inclusão dos corpos-de-prova, constatou-se que os sistemas adesivos acrescidos unicamente por verniz de clorexidina (G2 e G6) foram os únicos a demonstrarem atividade antimicrobiana de forma estatisticamente significante. Nenhum grupo experimental mostrou-se eficaz na prevenção à desmineralização do esmalte dental após a simulação do desafio cariogênico, através da ciclagem de pH. / Salvador
29

Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura

Mazur, Rui Fernando [UNESP] 10 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-10Bitstream added on 2014-06-13T20:41:47Z : No. of bitstreams: 1 mazur_rf_dr_arafo.pdf: 2691655 bytes, checksum: aa6766566238765dc0a1f4d5cb633eda (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... . / The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below).
30

Ação triboquímica do ciclo mastigatório na resistência ao cisalhamento de resinas compostas / Tribocorrosion effects of masticatory cycle on the composite resins shear bond strength

Marta Maria Martins Giamatei Contente 07 October 2013 (has links)
Este trabalho avaliou in vitro a ação de estímulos triboquímicos que simulam o ciclo mastigatório na resistência ao cisalhamento de duas resinas compostas Filtek P90®- 3M ESPE (P) e Z250®-3M ESPE (Z) com e sem presença de contaminação salivar, assim como a liberação de íons e a qualidade e a quantidade do desgaste produzido. A amostra foi composta por 12 grupos experimentais (n=5): P1 e Z1, sem contaminação/contra dente decíduo; P2 e Z2, com contaminação/contra dente decíduo; P3 e Z3, sem contaminação/contra dente permanente; P4 e Z4, com contaminação/contra dente permanente; P5 e Z5 sem contaminação (controle); P6 e Z6 com contaminação (controle). Ensaios de tribocorrosão foram efetuados na configuração pino-placa de deslizamento linear alternativo, na presença da solução de saliva artificial, carga de 3N e frequência de 1Hz, totalizando 900 ciclos de desgaste durante 15 minutos. As pistas de desgaste foram caracterizadas por MEV, EDX e XRD e o volume de desgaste por análise da variação de massa. A MEV demonstrou que os grupos Z apresentaram maior quantidade de desgaste quando comparados aos grupos P e que os antagonistas de dente permanente apresentaram maior quantidade de resíduos do material desgastado que os antagonistas em dentes decíduos. A análise por XRD não apresentou variação na caracterização de nenhuma das amostras quando se comparou os espécimes antes e após a realização dos experimentos. Na análise por EDX observou-se picos correspondentes aos elementos Ítrio e Silício para os antagonistas dos grupos P e de Zircônia para os dos grupos Z. Os dados obtidos pelo ensaio de nanoendentação não apresentaram diferença estatisticamente significante para nenhum dos grupos estudados (ANOVA e Teste de Duncan p&le;0,05). Nenhuma diferença estatisticamente significante foi encontrada pelos corpos de prova em resina composta ou antagonistas em nenhum dos grupos estudados quando da análise da variação de massa. Os valores de resistência ao cisalhamento foram: P1 11,20 (±1,44); P2 9,28 (±1,88); P3 8,94 (±1,03); P4 5,76 (±1,47); P5 17,50 (±3,28); P6 15,31 (±1,19); Z1 12,17 (±1,56); Z2 9,60 (±1,56); Z3 10,79 (±3,33); Z4 9,14 (±2,06); Z5 9,77 (±2,27) e Z6 9,22 (±1,98). Os valores de resistência ao cisalhamento foram menores para os grupos P submetidos à contaminação salivar. Na análise de ICP-MS maior liberação de íons Cálcio foi constatada em todos os grupos. A liberação de íons Fosfato foi observada na solução resultante do ensaio tribológico do corpo de prova em resina composta P90 contra antagonista dente permanente. Conclui-se que não há alterações químicas na superfície das resinas após o ensaio mecânico de desgaste e a resina composta P90 apresentou os menores valores de resistência ao cisalhamento em comparação com a resina Z250. A contaminação salivar interferiu negativamente nos valores de resistência ao cisalhamento quando a resina composta P90 foi avaliada. Dente utilizado como contra corpo não teve sua superfície alterada pela incorporação de resíduos de desgaste da resina composta, mantendo o módulo de elasticidade e a nanodureza, sendo que o desgaste ocorreu de forma mais acentuada nas restaurações de resina composta Z250. A liberação de íons Cálcio foi maior que a de íons Fosfato em todas as situações analisadas e a liberação de íons Fosfato foi maior na situação em que o corpo de prova em resina composta P90 foi submetido ao ensaio tribológico contra antagonista dente permanente. O ciclo mastigatório interferiu na resistência ao cisalhamento da resina composta P90. / This study evaluated in vitro the action of tribochemical stimuli simulating the masticatory cycle on the shear bond strength of two composite resins Filtek P90®- 3M ESPE (P) and Z250®-3M ESPE (Z) - with and without salivary contamination, as well as the release of ions and the quality and amount of composite resin/tooth wear. Twelve experimental groups (n=5) were formed: P1 and Z1, without contamination/against primary tooth; P2 and Z2, with contamination/against primary tooth; P3 and Z3, without contamination/against permanent tooth; P4 and Z4, with contamination/against permanent tooth; P5 and Z5, without contamination (control); P6 and Z6, with contamination (control). Tribocorrosion assays were performed using the pin-on-plate configuration under linear reciprocating sliding, in the presence of an artificial saliva solution and under 3 N load and 1 Hz frequency, totalizing 900 wear cycles during 15 minutes. The wear was characterized by SEM, EDX and XRD analyses and the wear volume was determined by mass variation analysis. The SEM analysis showed that the Z groups presented less wear than the P groups, and that the permanent tooth antagonists presented more worn material residues than the primary tooth antagonists. The XRD analysis did not reveal variation in the characterization of any of the samples, comparing the specimens before and after the experiments. The EDX analysis revealed peaks corresponding to the elements yttrium and silicon for the P groups\' antagonists and zircon for the Z groups\' antagonists. Data from the nanoindentation test did not show statistically significant difference for any of the groups (ANOVA and Duncan test p&le;0.05). For the mass variation analysis, no statistically significant difference was found between the composite resin specimens or antagonists in any of the groups. The shear bond strength results were: P1 11.20 (±1.44); P2 9.28 (±1.88); P3 8.94 (±1.03); P4 5.76 (±1.47); P5 17.50 (±3,28); P6 15,31 (±1.19); Z1 12.17 (±1.56); Z2 9,60 (±1.56); Z3 10.79 (±3.33); Z4 9.14 (±2.06); Z5 9.77 (±2.27) and Z6 9.22 (±1.98). The shear bond strength values were lower in the P groups subjected to salivary contamination. The ICP-MS analysis revealed greater calcium ion release in all groups. Regarding phosphate ion, greater release was observed in the solution resulting from the tribological assay when the P90 composite resin specimens were tested against permanent tooth antagonists. In conclusion, there were no chemical alterations on resin surface after the mechanical wear assay and P90 composite resin presented lower shear bond strength values than Z250 composite resin. Salivary contamination affected negatively in the shear bond strength values when P90 resin composite was evaluated. Teeth used as counterbody did not have their surface altered by the incorporation of composite resin wear residues, maintaining the modulus of elasticity and nano-hardness, and the wear was more accentuated in the Z250 composite resin restorations. There was greater release of calcium ions compared with phosphate ions in all analyzed situations and the release of phosphate ions increased when P90 was subjected to tribological assay against a permanent tooth antagonist. Tribochemical stimuli simulating the masticatory cycle interfered with the shear strength of composite resin P90.

Page generated in 0.056 seconds