351

Biopsy needles localization and tracking methods in 3d medical ultrasound with ROI-RANSAC-KALMAN / Méthodes de localisation et de suivi d’aiguille de biopsie en échographie 3D avec ROI-RANSAC-Kalman

Zhao, Yue 05 February 2014 (has links)
Dans les examens médicaux et les actes de thérapie, les techniques minimalement invasives sont de plus en plus utilisées. Des instruments comme des aiguilles de biopsie, ou des électrodes sont utilisés pour extraire des échantillons de cellules ou pour effectuer des traitements. Afin de réduire les traumatismes et de faciliter le suivi visuelle de ces interventions, des systèmes d’assistance par imagerie médicale, comme par exemple, par l’échographie 2D, sont utilisés dans la procédure chirurgicale. Nous proposons d’utiliser l’échographie 3D pour faciliter la visualisation de l’aiguille, mais en raison de l’aspect bruité de l’image ultrasonore (US) et la grande quantité de données d’un volume 3D, il est difficile de trouver l’aiguille de biopsie avec précision et de suivre sa position en temps réel. Afin de résoudre les deux principaux problèmes ci-dessus, nous avons proposé une méthode basée sur un algorithme RANSAC et un filtre de Kalman. De même l’étude est limitée à une région d’intérêt (ROI) pour obtenir une localisation robuste et le suivi de la position de l’aiguille de biopsie en temps réel. La méthode ROI-RK se compose de deux étapes: l’étape d’initialisation et l’étape de suivi. Dans la première étape, une stratégie d’initialisation d’une ROI en utilisant le filtrage de ligne à base de matrice de Hesse est mise en œuvre. Cette étape permet de réduire efficacement le bruit de granularité du volume US, et de renforcer les structures linéaires telles que des aiguilles de biopsie. Dans la deuxième étape, après l’initialisation de la ROI, un cycle de suivi commence. L’algorithme RK localise et suit l’aiguille de biopsie dans une situation dynamique. L’algorithme RANSAC est utilisé pour estimer la position des micro-outils et le filtrage de Kalman permet de mettre à jour la région d’intérêt et de corriger la localisation de l’aiguille. Une stratégie d’estimation de mouvement est également appliquée pour estimer la vitesse d’insertion de l’aiguille de biopsie. Des volumes 3D US avec un fond inhomogène ont été simulés pour vérifier les performances de la méthode ROI-RK. La méthode a été testée dans des conditions variables, telles que l’orientation d’insertion de l’aiguille par rapport à l’axe de la sonde et le niveau de contraste (CR). La précision de la localisation est de moins de 1 mm, quelle que soit la direction d’insertion de l’aiguille. Ce n’est que lorsque le CR est très faible que la méthode proposée peut échouer dans le suivi d’une structure incomplète de l’aiguille. Une autre méthode, utilisant l’algorithme RANSAC avec apprentissage automatique a été proposée. Cette méthode vise à classer les voxels en se basant non seulement sur l’intensité, mais aussi sur les caractéristiques de la structure de l’aiguille de biopsie. Les résultats des simulations montrent que l’algorithme RANSAC avec apprentissage automatique peut séparer les voxels de l’aiguille et les voxels de tissu de fond avec un CR faible. / In medical examinations and surgeries, minimally invasive technologies are getting used more and more often. Some specially designed surgical instruments, like biopsy needles, or electrodes are operated by radiologists or robotic systems and inserted in human’s body for extracting cell samples or delivering radiation therapy. To reduce the risk of tissue injury and facilitate the visual tracking, some medical vision assistance systems, as for example, ultrasound (US) systems can be used during the surgical procedure. We have proposed to use the 3D US to facilitate the visualization of the biopsy needle, however, due to the strong speckle noise of US images and the large calculation load involved as soon as 3D data are involved, it is a challenge to locate the biopsy needle accurately and to track its position in real time in 3D US. In order to solve the two main problems above, we propose a method based on the RANSAC algorithm and Kalman filter. In this method, a region of interest (ROI) has been limited to robustly localize and track the position of the biopsy needle in real time. The ROI-RK method consists of two steps: the initialization step and the tracking step. In the first step, a ROI initialization strategy using Hessian based line filter measurement is implemented. This step can efficiently reduce the speckle noise of the ultrasound volume, and enhance line-like structures as biopsy needles. In the second step, after the ROI is initialized, a tracking loop begins. The RK algorithm can robustly localize and track the biopsy needles in a dynamic situation. The RANSAC algorithm is used to estimate the position of the micro-tools and the Kalman filter helps to update the ROI and auto-correct the needle localization result. Because the ROI-RK method is involved in a dynamic situation, a motion estimation strategy is also implemented to estimate the insertion speed of the biopsy needle. 3D US volumes with inhomogeneous background have been simulated to evaluate the performance of the ROI-RK method. The method has been tested under different conditions, such as insertion orientations angles, and contrast ratio (CR). The localization accuracy is within 1 mm no matter what the insertion direction is. Only when the CR is very low, the proposed method could fail to track because of an incomplete ultrasound imaging of the needle. Another methodology, i.e. RANSAC with machine learning (ML) algorithm has been presented. This method aims at classifying the voxels not only depending on their intensities, but also using some structure features of the biopsy needle. The simulation results show that the RANSAC with ML algorithm can separate the needle voxels and background tissue voxels with low CR.
352

Metody potlačení strukturního šumu typu spekle / Speckle noise suppression methods in ultrasound images

Teplý, Lukáš Unknown Date (has links)
Ultrasound investigation is one of meaningful imaging at present. Advantages of ultrasound are, that it hasn´t side effects as a rtg radiation and it is noninvasive. Ultrasound diagnostic is exploited in all branch of medicine (urology, cardiology, orthopeadist, gynecology etc.) to display organs, tissues and cavities of the human body. We use display in 2D, 3D and most modern display in 4D. We can encounter with many kinds of artifact. Artifacts are described more closely at 3rd chapter. Speckle noise deteriorates informative yiled of ultrasound picture. We try to remove speckle noise by simpler methods or more complex methods of filtration. These methods are described at 5th chapter. Programme for speckle filtering from pictures is part of this master´s thesis.
353

Fonction auriculaire gauche dans la maladie de Fabry par analyse échocardiographique de la déformation myocardique

Pichette, Maxime 04 1900 (has links)
Contexte: La maladie de Fabry (MF) se caractérise par l'accumulation de sphingolipides dans de multiples organes dont l'oreillette gauche (OG). La littérature existante ne permet pas d'établir si les fonctions réservoir, conduit et pompe de l'OG étudiées par échocardiographie de suivi des marqueurs acoustiques (speckle-tracking echocardiography, STE) sont affectées dans la MF et si la thérapie de remplacement enzymatique (TRE) permet d'améliorer la fonction de l'OG. Méthodes: Dans cette étude de cohorte rétrospective, la déformation, le taux de déformation et les volumes phasiques de l'OG ont été étudiés chez 50 patients atteints de la MF et comparés à 50 contrôles sains. Résultats: Les trois fonctions phasiques de l'OG étaient altérées. La déformation positive maximale (fonction réservoir) était de 38,9 ± 14,9 % vs. 46,5 ± 10,9 % (p=0,004) et la déformation télédiastolique (fonction pompe) était de 12,6 ± 5,9 % vs. 15,6 ± 5,3 % (p=0,010). Chez 15 patients ayant débuté la TRE pendant l'étude, la majorité des paramètres de fonction de l'OG se sont améliorés après un suivi d'un an (déformation positive maximale de 32,0 ± 13,5 % à 38,0 ± 13,5 %; p=0,006) alors qu'il y a eu une tendance vers une détérioration des paramètres chez 15 patients n'ayant jamais reçu de traitement (déformation positive maximale de 47,3 ± 10,8 % à 41,3 ± 9,3 %; p=0,058). Neuf patients atteints de la MF (21%) ont développé une fibrillation auriculaire ou un accident vasculaire cérébral pendant un suivi de quatre ans. La déformation positive maximale et la déformation protodiastolique étaient plus fortement associés aux événements cliniques que les paramètres cliniques et les paramètres échocardiographiques standards. Conclusions: Les fonctions réservoir, conduit et pompe de l'OG par STE étaient affectées dans la MF. La TRE a permis d'améliorer la fonction de l'OG. Les paramètres de déformation de l'OG étaient associés à la survenue de fibrillation auriculaire et d'accidents vasculaires cérébraux. / Background: Fabry disease (FD) is characterized by the accumulation of sphingolipids in multiple organs including the left atrium (LA). It is uncertain if the LA reservoir, conduit and contractile functions evaluated by speckle-tracking echocardiography are affected in Fabry cardiomyopathy and whether enzyme replacement therapy can improve LA function. Methods: In this retrospective cohort study, LA strain, strain rates and phasic LA volumes were studied in 50 FD patients and compared to 50 healthy controls. Results: All three LA phasic functions were altered. The peak positive strain (reservoir function) was 38.9 ± 14.9 % vs. 46.5 ± 10.9 % (p=0.004) and the late diastolic strain (contractile function) was 12.6 ± 5.9 % vs. 15.6 ± 5.3 % (p=0.010). In 15 patients who started enzyme replacement therapy during the study, most of the LA parameters improved at one-year follow-up (peak positive strain from 32.0 ± 13.5 % to 38.0 ± 13.5 %; p=0.006) whereas there was a trend towards deterioration in 15 patients who never received treatment (peak positive strain from 47.3 ± 10.8 % to 41.3 ± 9.3 %; p=0.058). Nine FD patients (21%) experienced new-onset atrial fibrillation or stroke during four-year follow-up. By univariate analysis, peak positive strain and early diastolic strain demonstrated significant associations with clinical events, surpassing conventional echocardiographic parameters and clinical characteristics. Conclusions: Left atrial reservoir, conduit and contractile functions by speckle-tracking echocardiography were all affected in FD. Enzyme replacement therapy improved LA function. Left atrial strain parameters were associated with atrial fibrillation and stroke.
354

Zpracování obrazů ultrazvukového zobrazovacího systému GE VingMed System FiVe / Image processing of data from the ultrasound system GE VingMed System Five

Pokorný, Pavel January 2013 (has links)
The master thesis is focused on the principle of ultrasonographs and their modes, and ways of denoising data obtained by ultrasonographs. This project will also concentrate on removing the speckle noise, because the speckle noise has the largest share of the noise in the measured data in ultrasonographs. The other main objective was to describe advanced methods of filtration, especially the modifications of the median filter, such as the modified hybrid median filter and modification of the anisotropic diffusion, namely generalizing Perona-Malik anisotropic diffusion using restricted dissimilarity functions. These two filters were tested on images with artificial noise and on data captured using the ultrasound system GE VingMed System FiVe. Also, the program for filtering and display filtered ultrasound data captured by GE VingMed System FiVe is described.
355

Mechanics of Cross-Laminated Timber

Buck, Dietrich January 2018 (has links)
Increasing awareness of sustainable building materials has led to interest in enhancing the structural performance of engineered wood products. Wood is a sustainable, renewable material, and the increasing use of wood in construction contributes to its sustainability. Multi-layer wooden panels are one type of engineered wood product used in construction. There are various techniques to assemble multi-layer wooden panels into prefabricated, load-bearing construction elements. Assembly techniques considered in the earliest stages of this research work were laminating, nailing, stapling, screwing, stress laminating, doweling, dovetailing, and wood welding. Cross-laminated timber (CLT) was found to offer some advantages over these other techniques. It is cost-effective, not patented, offers freedom of choice regarding the visibility of surfaces, provides the possibility of using different timber quality in the same panel at different points of its thickness, and is the most well-established assembly technique currently used in the industrial market. Building upon that foundational work, the operational capabilities of CLT were further evaluated by creating panels with different layer orientations. The mechanical properties of CLT panels constructed with layers angled in an alternative configuration produced on a modified industrial CLT production line were evaluated. Timber lamellae were adhesively bonded in a single-step press procedure to form CLT panels. Transverse layers were laid at a 45° angle instead of the conventional 90° angle with respect to the longitudinal layers’ 0° angle. Tests were carried out on 40 five-layered CLT panels, each with either a ±45° or a 90° configuration. Half of these panels were evaluated under bending: out-of-plane loading was applied in the principal orientation of the panels via four-point bending. The other twenty were evaluated under compression: an in-plane uniaxial compressive loading was applied in the principal orientation of the panels. Quasi-static loading conditions were used for both in- and out-of-plane testing to determine the extent to which the load-bearing capacity of such panels could be enhanced under the current load case. Modified CLT showed higher stiffness, strength, and fifth-percentile characteristics, values that indicate the load-bearing capacity of these panels as a construction material. Failure modes under in- and out-of-plane loading for each panel type were also assessed. Data from out-of-plane loading were further analysed. A non-contact full-field measurement and analysis technique based on digital image correlation (DIC) was utilised for analysis at global and local scales. DIC evaluation of 100 CLT layers showed that a considerable part of the stiffness of conventional CLT is reduced by the shear resistance of its transverse layers. The presence of heterogeneous features, such as knots, has the desirable effect of reducing the propagation of shear fraction along the layers. These results call into question the current grading criteria in the CLT standard. It is suggested that the lower timber grading limit be adjusted for increased value-yield. The overall experimental results suggest the use of CLT panels with a ±45°-layered configuration for construction. They also motivate the use of alternatively angled layered panels for more construction design freedom, especially in areas that demand shear resistance. In addition, the design possibility that such 45°-configured CLT can carry a given load while using less material than conventional CLT suggests the potential to use such panels in a wider range of structural applications. The results of test production revealed that 45°-configured CLT can be industrially produced without using more material than is required for construction of conventional 90°-configured panels. Based on these results, CLT should be further explored as a suitable product for use in more wooden-panel construction. / <p>External cooperation: Martinson Group AB and Research Institutes of Sweden (RISE)</p>
356

SHEAR RHEOMETRY PROTOCOLS TO ADVANCE THE DEVELOPMENT OF MICROSTRUCTURED FLUIDS

Eduard Andres Caicedo Casso (6620462) 15 May 2019 (has links)
<p></p><p>This doctoral dissertation takes the reader through a journey where applied shear rheology and flow-velocimetry are used to understand the mesoscopic factors that control the flow behavior of three microstructured fluids. Three individual protocols that measure relative physical and mechanical properties of the flow are developed. Each protocol aims to advance the particular transformation of novel soft materials into a commercial product converging in the demonstration of the real the chemical, physical and thermodynamical factors that could potentially drive their successful transformation. </p> <p> </p> <p>First, this dissertation introduces the use of rotational and oscillatory shear rheometry to quantify the solvent evaporation effect on the flow behavior of polymer solutions used to fabricate isoporous asymmetric membranes. Three different A-B-C triblock copolymer were evaluated: polyisoprene-<i>b</i>-polystyrene-<i>b</i>-poly(4-vinylpyridine) (ISV); polyisoprene-<i>b</i>-polystyrene-<i>b</i>-poly(<i>N</i>,<i>N</i>-dimethylacrylamide) (ISD); and polyisoprene-<i>b</i>-polystyrene-<i>b</i>-poly(<i>tert</i>-butyl methacrylate) (ISB). The resulting evaporation-induced microstructure showed a solution viscosity and film viscoelasticity strongly dependent on the chemical structure of the triblock copolymer molecules. </p> <p> </p> <p>Furthermore, basic shear rheometry, flow birefringence, and advanced flow-velocimetry are used to deconvolute the flow-microstructure relationships of concentrated surfactant solutions. Sodium laureth sulfate in water (SLE<sub>1</sub>S) was used to replicate spherical, worm-like, and hexagonally packed micelles and lamellar structures. Interesting findings demonstrated that regular features of flow curves, such as power-law shear thinning behavior, resulted from a wide variety of experimental artifacts that appeared when measuring microstructured fluids with shear rheometry.</p> <p> </p> <p>Finally, the successful integration of shear rheometry to calculate essential parameters to be used in a cost-effective visualization technique (still in development) used to calculate the dissolution time of polymers is addressed. The use of oscillatory rheometry successfully quantify the viscoelastic response of polyvinyl alcohol (PVA) solutions and identify formulations changes such as additive addition. The flow behavior of PVA solutions was correlated to dissolution behavior proving that the developed protocol has a high potential as a first screening tool.</p><br><p></p>
357

Microscopies de fluorescence et de diffraction super-résolues par éclairement multiple

Girard, Jules 02 December 2012 (has links) (PDF)
Ce travail de thèse concerne l'amélioration du pouvoir de résolution de la microscopie optique en champ lointain. Nous avons étudié et développé des techniques permettant de dépasser la limite fondamentale de résolution établie par Abbe en 1873. Toutes tirent profit de la relation liant le champ électromagnétique émis ou diffracté par un objet à l'éclairement employé pour l'observer. En enregistrant plusieurs images du même objet sous différents éclairements, puis en utilisant un algorithme d'inversion approprié, il est possible d'avoir accès à certaines fréquences spatiales de l'objet qui sont habituellement filtrées par le microscope. Ce concept est d'abord appliqué à une technique de microscopie cohérente ne nécessitant pas le marquage de l'échantillon : la microscopie tomographique de diffraction. Cette méthode permet de reconstruire numériquement des cartes quantitatives de la permittivité diélectrique de l'objet avec une résolution significativement meilleure que celle d'un microscope large-champ classique à partir de plusieurs hologrammes de l'échantillon obtenus sous diverses incidences. Nous montrons théoriquement et expérimentalement que, loin d'être un désavantage, le phénomène de diffusion multiple permet, s'il est correctement pris en compte, d'atteindre des résolutions encore plus spectaculaires. Nous étudions ensuite, avec des outils conceptuellement proches, la microscopie de fluorescence par éclairement structuré. Nous avons proposé deux approches différentes pour améliorer cette technique de microscopie. La première tire profit du développement d'un algorithme d'inversion capable de retrouver la densité de fluorescence de l'objet sans connaitre les éclairements utilisés a priori. Grâce à cet algorithme, nous pouvons remplacer le motif d'illumination habituellement périodique et contrôlé de la microscopie à éclairement structuré classique par des speckles aléatoires obtenus en bougeant un diffuseur à travers un faisceau laser. Des résultats expérimentaux très encourageants montrent l'efficacité de cette approche dont la mise en œuvre expérimentale est remarquablement simple. La seconde consiste à remplacer la lamelle de verre sur laquelle est déposé l'échantillon par une lamelle périodiquement nanostructurée. Celle-ci crée à sa surface une grille de lumière de période bien inférieure à la limite imposée par la diffraction, et qui peut être utilisée pour sonder les fréquences spatiales les plus élevées de l'échantillon. Nous détaillons la conception, la fabrication et la caractérisation expérimentale de ce substrat nanostructuré.
358

Spektroskopie und Polarimetrie kleinskaliger magnetischer Strukturen der Sonnenoberfläche mit Methoden der Bildrekonstruktion / Spectroscopy and polarimetry of small-scale magnetic structures on the solar surface with image restoration techniques

Koschinsky, Markus 03 May 2001 (has links)
No description available.