• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 1
  • Tagged with
  • 57
  • 57
  • 47
  • 38
  • 18
  • 15
  • 11
  • 11
  • 11
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Aplicação da metodologia de análise de perigo e pontos críticos de controle na disposição de efluentes tratados em solos tropicais e seu potencial uso agrícola / Application of risk analysis methodology and critical control points at the disposal of treated effluent in tropical soils and their potential agricultural use.

Santos, Jeferson Gaspar dos 07 June 2016 (has links)
Introdução - A prática de reúso pela aplicação de esgotos tratados na agricultura atualmente é considerada parte integrante dos recursos hídricos por muitas nações. No entanto, oferece riscos à saúde da população pela presença de bactérias, cistos de protozoários, ovos de helmintos e vírus, capazes de sobreviver por longos períodos em ambientes desfavoráveis e apresentarem um curto tempo entre a infecção e o desenvolvimento da doença. Objetivo - Estabelecer medidas preventivas para o lançamento de efluentes nos ecossistemas aquáticos, controle sanitário na redução de patógenos transmitidos por águas contaminadas e a disposição de efluentes tratados em solos tropicais como ferramentas de auxílio do manejo integrado dos recursos hídricos em bacias hidrográficas, por meio do uso de metodologia de gerenciamento de risco com aplicação do Sistema APPCC, em um conjunto de tecnologias na produção de efluente tratado de esgoto de origem doméstica para avaliar o potencial de emprego em solos agrícolas. Métodos - A pesquisa foi desenvolvida na estação de tratamento de esgoto e no campo experimental para pesquisas de utilização de efluente na agricultura no município de Lins. Os indicadores biológicos estudados e os pontos de amostragem foram determinados através da utilização da metodologia de controle de qualidade Análise de Perigos e Pontos Críticos de Controle (APPCC). Foram coletadas amostras do solo irrigado e dos poços de monitoramento do lençol freático. As amostras foram submetidas a análises físico-químicas, microbiológicas e parasitológicas. Aos resultados obtidos foi aplicada a Avaliação Quantitativa do Risco Microbiológico, para a determinação do risco anual de infecção. Resultados - O efluente final apresentou concentrações médias de 8,13x105 NMP/100 mL de coliformes totais e 4,69x105 NMP/100 mL de Escherichia coli, não sendo observados ovos de helmintos. O solo apresentou maior concentração de coliformes totais e E. coli na camada superficial 1,01x106 e 8,70x103, diminuindo ao longo da profundidade. Os ovos de helmintos foram encontrados entre a superfície e os 15 cm de profundidade em concentrações entre 0,07 e 0,87 ovos/g de peso seco. Foi constatada a presença de adenovírus em concentração de 3,56x105 cópias genômicas/g entre os 5 e 10 cm de profundidade em 2015. Nos poços de monitoramento foram constatadas concentrações de coliformes totais variando entre < 1,00 e 1,01x103 NMP/100 mL e E. coli entre <1,00 e 1,00x100 NMP/100 mL. Não foi observada a presença de vírus entéricos. O risco anual de infecção estimado para E. coli no efluente final foi 1,02x10-2 pppa, no solo variou entre 2,68x10-3 e 7,59x10-3 pppa e nos poços de monitoramento variou entre 1,42x10-8e 4,38x10-9 pppa. Para os ovos de helmintos observados no efluente do tratamento primário o risco anual de infecção calculado foi 4,04x10-2 pppa e no solo variou entre 9,57x10-1 e 9,76x10-1 pppa. Conclusões No período da pesquisa, as amostras dos sistemas de tratamento de esgoto e de irrigação demonstraram atender as expectativas de remoção de patógenos condizentes aos seus parâmetros de projeto, havendo restrições para seu lançamento em corpos hídricos e aplicação na agricultura. O solo mostrou capacidade de retenção dos organismos patogênicos nos primeiros 60 cm de profundidade, reduzindo as suas concentrações a níveis inferiores a 1,00 NMP/100 mL nos aquíferos. / Introduction - Currently, the practice of reuse through the application of treated sewage in agriculture considers an integral part of water resources for many nations. However, threatens the health of the population by the presence of bacteria, protozoan cysts, helminth eggs and viruses able to survive for long periods in harsh environments and present a short time between infection and development of disease. Objective - Establish preventive measures for the release of effluents on aquatic ecosystems, sanitary control in the reduction of pathogens transmitted by contaminated water and the disposal of treated effluent in tropical soils as aid tools in integrated management of water resources in river basins. For this purpose it was employed as risk management methodology the Hazard Analysis and Critical Control Points system (HACCP) in a set of technologies in the treated effluent production of domestic sewage to assess the employment potential in agricultural soils. Methods - The study was conducted in the sewage treatment plant and in an adjoining experimental field situated at Lins city. The biological indicators and the sampling points were determined by using the quality control methodology Hazard Analysis and Critical Control Points (HACCP). Samples of irrigated soil and groundwater monitoring wells were collected. The samples were subjected to analysis, physical-chemical, microbiological and parasitological. The results obtained was applied to Quantitative Microbial Risk Assessment (QRMA), for determining the annual risk of infection. Results - The final effluent presented average concentrations of 8.13x105 MPN / 100 mL of total coliforms and 4.69x105 MPN / 100 mL of Escherichia coli, not being observed helminth eggs. The soil showed the highest concentration of total coliforms and E. coli in the surface layer and 1.01x106 8.70x103, decreasing along the depth. Eggs from helminths were found between the surface and 15 cm depth in concentrations from 0.07 to 0.87 eggs / g dry weight. It was found the presence of adenovirus in concentration 3.56x105 genomic copies / g between 5 and 10 cm depth in 2015. In monitoring wells total coliform concentrations were found ranging from <1.00 and 1.01x103 NMP / 100 mL and E. coli between <1.00 and 1.00x100 MPN / 100 mL. It was not observed the presence of enteric viruses. The estimated annual risk of infection to E. coli in the final effluent was 1.02x10-2 pppy, soil ranged from 2.68x10-3 and 7.59x10-3 pppy and monitoring wells ranged from 1.42x10-8 e 4.38x10-9 pppy. For helminth eggs observed in the effluent from the primary treatment, the annual risk of infection was calculated 4.04x10-2 pppy and soil ranged from 9.57x10-1 and 9.76x10-1 pppy. Conclusions - During the survey period, samples of sewage and irrigation treatment systems showed meet the expectation removal of pathogens consistent to its design parameters, with restrictions on its release in water and applied in agriculture bodies. The soil of pathogenic organisms showed retention capacity in the first 60 cm depth by reducing its concentration to levels below 1.00 MPN / 100 mL in aquifers.
42

Pós-tratamento e desinfecção de efluentes de reatores UASB e de lagoas de estabilização visando ao uso agrícola. / Post-treatment and disinfection of effluent from UASB reactors and of stabilization ponds, aiming to use in agricultural soils.

Gilberto Carlos Sundefeld Júnior 25 July 2012 (has links)
Estudaram-se soluções para o pós-tratamento de efluentes de reatores UASB e de lagoas de estabilização visando à utilização em irrigação de culturas agrícolas. Nesta aplicação, normalmente são desejáveis bons níveis de remoção de sólidos em suspensão e graus elevados de desinfecção, além da conservação dos principais nutrientes. No caso do efluente de reatores UASB em escala real, foram construídas unidades em escala piloto envolvendo sedimentação, filtração e radiação UV. No primeiro experimento, o efluente dos reatores UASB passou por filtro de areia pressurizado em alta taxa e por reator UV de fluxo contínuo. Nesta etapa a concentração de sólidos em suspensão (SST) no efluente dos reatores UASB teve média de 233 mg/L, devido a problemas operacionais, sendo que o filtro apresentou eficiência média de 60% de remoção de sólidos em suspensão. Porém, como o filtrado apresentou absorbância ainda elevada, média de 0,476 cm-¹, a desinfecção UV resultou ineficiente e a contagem de coliformes do efluente final incompatível com o uso agronômico pretendido. No segundo experimento, o efluente dos reatores UASB recebeu tratamento complementar passando por decantador de alta taxa e filtração em leito de manta geotêxtil, seguindo finalmente para a desinfecção UV. A concentração de SST no efluente dos reatores UASB, sanados os problemas operacionais da ETE teve valor médio de 82 mg/L. Com essa concentração afluente relativamente baixa, o decantador lamelar demonstrou-se pouco eficiente e apresentou efluente com SST médio de 67 mg/L. No entanto, foi bastante útil para conter picos de concentração de sólidos no efluente dos reatores UASB, protegendo a etapa posterior de filtração. No efluente do filtro de manta geotêxtil, o SST médio foi de apenas 7 mg/L., ABS (254nm) de 0,245 cm-1 e Turbidez de 11 UNT. A desinfecção do efluente por radiação ultravioleta com dose recebida de 2,44 W.h/m³, resultou satisfatória com média geométrica de 1,12x101 NMP/100mL de E coli. No caso do efluente de sistema de lagoas de estabilização em escala real, aplicou-se pós-tratamento em escala piloto composto de filtro de areia pressurizado de alta taxa seguido de desinfecção por hipoclorito de sódio. A concentração de SST no efluente da lagoa facultativa teve média de 117 mg/L, enquanto que a média no efluente do filtro foi de 87 mg/L. Para concentrações de cloro dosado de 2,9; 6,2 e 11,7 mg/L, as médias geométricas das densidades de E coli no efluente final resultaram 1,13x10² NMP/100mL, 1,01x101 NMP/100mL e valor não detectado pelo método, respectivamente. Concluiu-se que é possível aplicar pós-tratamentos relativamente simples aos efluentes de reatores UASB e de lagoas de estabilização, quando se deseja uso agronômico e as principais condições operacionais destas unidades puderam ser avaliadas. / It was studied the application of a simple and economical post-treatment of effluent from wastewater treatment plant for the purpose of use on irrigation of agricultural crops. The research was conducted in two different wastewater treatment plants, (1) WTP UASB reactors with two application of post-treatment: (1.1) Post treatment with a sand bed filter pressurized at high-rate followed by ultraviolet disinfection. In this step, the concentration of suspended solids (TSS) in the effluent from the UASB reactor was 233 mg/L, the filter had efficiencies of 60% removal of suspended solids in the effluent from the UASB reactor, however, was not an appropriate result for effective disinfection of the effluent in the ultraviolet reactor. Absorbance values reached an average of 0.476 cm-¹. (1.2) Post-treatment at a high rate clarifier and on geotextile bed filtration to apply the ultraviolet disinfection. The concentration of TSS in the UASB reactor effluent has an average value of 82 mg/L, the concentration of the same parameter in the effluent from the clarifier was 67 mg/L and effluent of the filter geotextile, 7 mg/L. The system removed 91% of TSS in the effluent of the UASB reactor. In this experiment there was obtained a post-treated effluent with ABS (254nm) of 0.245 cm-1 and a turbidity of 11 NTU. The disinfection of the effluent by ultraviolet radiation with a dose received of 2.44 W.h/m³, obtained satisfactory results with geometric mean of 1.12x101 NMP/100mL E coli. (2) WTP by stabilization ponds with post-treatment in a pressurized sand filter followed by highrate disinfection by sodium hypochlorite solution. A TSS concentration in the effluent from facultative pond had an averaged 117 mg/L, the concentration of the same parameter in the effluent of the filter was 87 mg/L. With application of 2.88 mgCl2/L resulted in 1.13x10² NMP/100mL E coli, for the application of 6.2 and 11.7 mg/L chlorine was obtained 1.01x101 NMP/100mL E coli and ND, respectively.
43

Aplicação da metodologia de análise de perigo e pontos críticos de controle na disposição de efluentes tratados em solos tropicais e seu potencial uso agrícola / Application of risk analysis methodology and critical control points at the disposal of treated effluent in tropical soils and their potential agricultural use.

Jeferson Gaspar dos Santos 07 June 2016 (has links)
Introdução - A prática de reúso pela aplicação de esgotos tratados na agricultura atualmente é considerada parte integrante dos recursos hídricos por muitas nações. No entanto, oferece riscos à saúde da população pela presença de bactérias, cistos de protozoários, ovos de helmintos e vírus, capazes de sobreviver por longos períodos em ambientes desfavoráveis e apresentarem um curto tempo entre a infecção e o desenvolvimento da doença. Objetivo - Estabelecer medidas preventivas para o lançamento de efluentes nos ecossistemas aquáticos, controle sanitário na redução de patógenos transmitidos por águas contaminadas e a disposição de efluentes tratados em solos tropicais como ferramentas de auxílio do manejo integrado dos recursos hídricos em bacias hidrográficas, por meio do uso de metodologia de gerenciamento de risco com aplicação do Sistema APPCC, em um conjunto de tecnologias na produção de efluente tratado de esgoto de origem doméstica para avaliar o potencial de emprego em solos agrícolas. Métodos - A pesquisa foi desenvolvida na estação de tratamento de esgoto e no campo experimental para pesquisas de utilização de efluente na agricultura no município de Lins. Os indicadores biológicos estudados e os pontos de amostragem foram determinados através da utilização da metodologia de controle de qualidade Análise de Perigos e Pontos Críticos de Controle (APPCC). Foram coletadas amostras do solo irrigado e dos poços de monitoramento do lençol freático. As amostras foram submetidas a análises físico-químicas, microbiológicas e parasitológicas. Aos resultados obtidos foi aplicada a Avaliação Quantitativa do Risco Microbiológico, para a determinação do risco anual de infecção. Resultados - O efluente final apresentou concentrações médias de 8,13x105 NMP/100 mL de coliformes totais e 4,69x105 NMP/100 mL de Escherichia coli, não sendo observados ovos de helmintos. O solo apresentou maior concentração de coliformes totais e E. coli na camada superficial 1,01x106 e 8,70x103, diminuindo ao longo da profundidade. Os ovos de helmintos foram encontrados entre a superfície e os 15 cm de profundidade em concentrações entre 0,07 e 0,87 ovos/g de peso seco. Foi constatada a presença de adenovírus em concentração de 3,56x105 cópias genômicas/g entre os 5 e 10 cm de profundidade em 2015. Nos poços de monitoramento foram constatadas concentrações de coliformes totais variando entre < 1,00 e 1,01x103 NMP/100 mL e E. coli entre <1,00 e 1,00x100 NMP/100 mL. Não foi observada a presença de vírus entéricos. O risco anual de infecção estimado para E. coli no efluente final foi 1,02x10-2 pppa, no solo variou entre 2,68x10-3 e 7,59x10-3 pppa e nos poços de monitoramento variou entre 1,42x10-8e 4,38x10-9 pppa. Para os ovos de helmintos observados no efluente do tratamento primário o risco anual de infecção calculado foi 4,04x10-2 pppa e no solo variou entre 9,57x10-1 e 9,76x10-1 pppa. Conclusões No período da pesquisa, as amostras dos sistemas de tratamento de esgoto e de irrigação demonstraram atender as expectativas de remoção de patógenos condizentes aos seus parâmetros de projeto, havendo restrições para seu lançamento em corpos hídricos e aplicação na agricultura. O solo mostrou capacidade de retenção dos organismos patogênicos nos primeiros 60 cm de profundidade, reduzindo as suas concentrações a níveis inferiores a 1,00 NMP/100 mL nos aquíferos. / Introduction - Currently, the practice of reuse through the application of treated sewage in agriculture considers an integral part of water resources for many nations. However, threatens the health of the population by the presence of bacteria, protozoan cysts, helminth eggs and viruses able to survive for long periods in harsh environments and present a short time between infection and development of disease. Objective - Establish preventive measures for the release of effluents on aquatic ecosystems, sanitary control in the reduction of pathogens transmitted by contaminated water and the disposal of treated effluent in tropical soils as aid tools in integrated management of water resources in river basins. For this purpose it was employed as risk management methodology the Hazard Analysis and Critical Control Points system (HACCP) in a set of technologies in the treated effluent production of domestic sewage to assess the employment potential in agricultural soils. Methods - The study was conducted in the sewage treatment plant and in an adjoining experimental field situated at Lins city. The biological indicators and the sampling points were determined by using the quality control methodology Hazard Analysis and Critical Control Points (HACCP). Samples of irrigated soil and groundwater monitoring wells were collected. The samples were subjected to analysis, physical-chemical, microbiological and parasitological. The results obtained was applied to Quantitative Microbial Risk Assessment (QRMA), for determining the annual risk of infection. Results - The final effluent presented average concentrations of 8.13x105 MPN / 100 mL of total coliforms and 4.69x105 MPN / 100 mL of Escherichia coli, not being observed helminth eggs. The soil showed the highest concentration of total coliforms and E. coli in the surface layer and 1.01x106 8.70x103, decreasing along the depth. Eggs from helminths were found between the surface and 15 cm depth in concentrations from 0.07 to 0.87 eggs / g dry weight. It was found the presence of adenovirus in concentration 3.56x105 genomic copies / g between 5 and 10 cm depth in 2015. In monitoring wells total coliform concentrations were found ranging from <1.00 and 1.01x103 NMP / 100 mL and E. coli between <1.00 and 1.00x100 MPN / 100 mL. It was not observed the presence of enteric viruses. The estimated annual risk of infection to E. coli in the final effluent was 1.02x10-2 pppy, soil ranged from 2.68x10-3 and 7.59x10-3 pppy and monitoring wells ranged from 1.42x10-8 e 4.38x10-9 pppy. For helminth eggs observed in the effluent from the primary treatment, the annual risk of infection was calculated 4.04x10-2 pppy and soil ranged from 9.57x10-1 and 9.76x10-1 pppy. Conclusions - During the survey period, samples of sewage and irrigation treatment systems showed meet the expectation removal of pathogens consistent to its design parameters, with restrictions on its release in water and applied in agriculture bodies. The soil of pathogenic organisms showed retention capacity in the first 60 cm depth by reducing its concentration to levels below 1.00 MPN / 100 mL in aquifers.
44

Caracterização dos meios de cultivo de viveiros de carcinicultura e da lagoa de disposição dos efluentes no Rio Grande do Norte: subsídios para proteção dos ecossistemas deste estudo / Characterization of shrimp ponds and effluents sedimentation pond in Rio Grande do Norte: subsidies to the protection of the ecosystems in this study

Paulo Eduardo Vieira Cunha 04 March 2005 (has links)
O cultivo de camarões é uma importante atividade econômica em zonas costeiras de muitos países. No Brasil, a carcinicultura teve início no Rio Grande do Norte em 1973 e, atualmente, consolida-se como principal produto da pauta de exportação desse estado, sucesso devido principalmente ao seu clima semi-árido, à vasta costa litorânea com extensas áreas estuarinas e lagoas costeiras, à topografia e ao solo, todos eles fatores adequados a essa atividade. A carcinicultura exerce importante papel sócio econômico, ético e de cidadania por: criar empregos em diferentes níveis de trabalho; minimizar os índices de pobreza; incentivar a dieta alimentar rica em proteínas além de, drasticamente, reduzir a superexploração de recursos naturais costeiros. O custo deste empreendimento é o árduo contraponto de ordem ambiental - a indiscutível necessidade de proteger os ecossistemas dos quais fazem parte as fazendas de camarão - única forma de essa atividade garantir sua sustentabilidade. Para impedir o desequilíbrio ecológico é preciso haver permanente monitoramento dos ecossistemas, como forma de evitar a desestabilização ambiental - devida ao desordenado uso e ocupação do solo nos ecossistemas - e garantir que as fazendas continuem produtivas. Com o propósito de fornecer subsídios para a sustentabilidade da carcinicultura, neste trabalho foi realizada a caracterização físico-química dos ecossistemas que compõem as fazendas de cultivo - manancial e captação, viveiros e seus efluentes - segundo os parâmetros estabelecidos pela resolução nº 312 do CONAMA, de 10 de outubro de 2002. Especial atenção foi dada à lagoa de decantação, por terem sido constatadas necessidades de adequações para seu correto funcionamento. A hipótese que os efluentes de carcinicultura não tem características que permitam seu descarte em corpos de água por não atenderem aos padrões estabelecidos na legislação brasileira, foi confirmada em função das altas concentrações de DBO. Essa hipótese, testada com o objetivo da concluir da necessidade ou não do uso da bacia de sedimentação para tratamento dos referidos efluentes, indicou ser imprescindível a existência desse sistema para promover a decantação de material sólido e a estabilização da matéria orgânica. / The shrimp culture is an important economic factor in coast areas in a lot of countries. In Brasil, the carcinicultura starts in Rio Grande do Norte in 1973, and actually shrimp is the principal commodity of exportation, specially because of climatic conditions, spread coast area and topography. This activity carries out an important social-economic development, although causes environmental impacts. The environmental monitory is an important tool to maintain the ecological equilibration. This research proposes subsidy the sustentability of carcinicultura by studying the physical-chemical characterization of the culture ecosystems, that composes the farm according to the variables established in the CONAMA resolution nº 312. Special attention was given to the sedimentation pond, because it needs to its best function. It was observed that carcinicultura wastewater can\'t be discarded without treatment, because they don\'t attend what is established in the brazilian legislation, due of BOD concentrations.
45

Estudo da ocorrência do gênero Aeromonas em sistemas de tratamento de esgotos por lagoas de estabilização no Município de Lins - SP / The ocurrence of the genus Aeromonas in wastewater treatment systems by stabilization ponds in the City of Lins, SP.

Solange Martone Rocha 24 September 2004 (has links)
Introdução: Organismos pertencentes ao gênero Aeromonas estão amplamente distribuídos no ambiente aquático sendo atualmente considerados como patógenos emergentes. Estudos demonstraram que, estes podem produzir uma série de fatores de virulência, e ainda um maior número de casos clínicos vêm sendo confirmados e atribuídos às diferentes espécies de Aeromonas. Objetivo: Estudar a ocorrência do gênero Aeromonas em efluentes de um sistema de lagoas de estabilização e discutir o significado da presença destes para a saúde pública. Métodos: A determinação de Aeromonas spp foi realizada pela técnica de tubos múltiplos (NMP/100 mL). Para a verificação da presença e ausência (PA) as colônias foram isoladas em ágar sangue ampicilina, ágar amido ampicilina e ágar MacConkey. As colônias que apresentaram resultados presuntivos para o grupo Aeromonas foram submetidas ao reisolamento em Ágar Amido, e a provas bioquímicas para identificação das espécies. O perfil plasmidial foi realizado de acordo com a metodologia descrita por BIRNBOIN & DOLLY 1979. Resultados: Aeromonas spp foram isoladas em 72,4% e 55,1% das amostras provenientes da entrada e saída da lagoa anaeróbia respectivamente, e em 48,3% da saída da lagoa facultativa variando as contagens entre <3 e 3,0x109 NMP/100mL. Na unidade de desinfecção por cloro entre <3 e 9,0 x 105 NMP/mL Conclusões: Observou-se que embora haja uma tendência de decaimento nas contagens de Aeromonas, não é possível eliminá-las do sistema estudado, mesmo após cloração. Esses organismos podem representar um risco à saúde devido à seleção de cepas resistentes que são lançadas no meio ambiente. / Introduction: Organisms of the genus Aeromonas are widely distributed in the aquatic environment, being now considered emerging organisms. Studies show that these organisms can produce a series of virulence factors, and that a major number of clinic cases have been confirmed and attributed to the different species of Aeromonas. Objective: Study the occurrence of the genus Aeromonas in effluents of a stabilization ponds system and discuss the meaning of the presence of these organisms for public health. Methods: Aeromonas spp determination was carried out by the most probable number technique (NMP/100mL). To verify the presence or absence, the colonies were isolated in ampicilin blood agar, starch agar, and Mc Conkey agar. Colonies showing presumptive results for Aeromonas group were re isolated in starch agar and to biochemical tests to identify the specie. The plasmidial profile was carried out according to the methodology described by BIRNBOIN & DOLLY 1979. Results: Aeromonas spp were isolated in 72,4% and 55.1% of the samples from the afluent and the end of anaerobic lagoons, respectively, in 48.3% of the effluent of the facultative lagoon in counts that varied from <3 and 3.0x109 NMP/100mL. In the disinfection unit counts varied from <3 and 9.0x105 NMP/100mL. Conclusions: It was possible to observe that even though a tendency of decaiment was noted for the counts of Aeromonas, it was not possible to totally eliminate this organisms from the studied system, even after the chlorination. These organisms could pose a health risk due to the selection of resistant strains released in the environment
46

Caracterização dos meios de cultivo de viveiros de carcinicultura e da lagoa de disposição dos efluentes no Rio Grande do Norte: subsídios para proteção dos ecossistemas deste estudo / Characterization of shrimp ponds and effluents sedimentation pond in Rio Grande do Norte: subsidies to the protection of the ecosystems in this study

Cunha, Paulo Eduardo Vieira 04 March 2005 (has links)
O cultivo de camarões é uma importante atividade econômica em zonas costeiras de muitos países. No Brasil, a carcinicultura teve início no Rio Grande do Norte em 1973 e, atualmente, consolida-se como principal produto da pauta de exportação desse estado, sucesso devido principalmente ao seu clima semi-árido, à vasta costa litorânea com extensas áreas estuarinas e lagoas costeiras, à topografia e ao solo, todos eles fatores adequados a essa atividade. A carcinicultura exerce importante papel sócio econômico, ético e de cidadania por: criar empregos em diferentes níveis de trabalho; minimizar os índices de pobreza; incentivar a dieta alimentar rica em proteínas além de, drasticamente, reduzir a superexploração de recursos naturais costeiros. O custo deste empreendimento é o árduo contraponto de ordem ambiental - a indiscutível necessidade de proteger os ecossistemas dos quais fazem parte as fazendas de camarão - única forma de essa atividade garantir sua sustentabilidade. Para impedir o desequilíbrio ecológico é preciso haver permanente monitoramento dos ecossistemas, como forma de evitar a desestabilização ambiental - devida ao desordenado uso e ocupação do solo nos ecossistemas - e garantir que as fazendas continuem produtivas. Com o propósito de fornecer subsídios para a sustentabilidade da carcinicultura, neste trabalho foi realizada a caracterização físico-química dos ecossistemas que compõem as fazendas de cultivo - manancial e captação, viveiros e seus efluentes - segundo os parâmetros estabelecidos pela resolução nº 312 do CONAMA, de 10 de outubro de 2002. Especial atenção foi dada à lagoa de decantação, por terem sido constatadas necessidades de adequações para seu correto funcionamento. A hipótese que os efluentes de carcinicultura não tem características que permitam seu descarte em corpos de água por não atenderem aos padrões estabelecidos na legislação brasileira, foi confirmada em função das altas concentrações de DBO. Essa hipótese, testada com o objetivo da concluir da necessidade ou não do uso da bacia de sedimentação para tratamento dos referidos efluentes, indicou ser imprescindível a existência desse sistema para promover a decantação de material sólido e a estabilização da matéria orgânica. / The shrimp culture is an important economic factor in coast areas in a lot of countries. In Brasil, the carcinicultura starts in Rio Grande do Norte in 1973, and actually shrimp is the principal commodity of exportation, specially because of climatic conditions, spread coast area and topography. This activity carries out an important social-economic development, although causes environmental impacts. The environmental monitory is an important tool to maintain the ecological equilibration. This research proposes subsidy the sustentability of carcinicultura by studying the physical-chemical characterization of the culture ecosystems, that composes the farm according to the variables established in the CONAMA resolution nº 312. Special attention was given to the sedimentation pond, because it needs to its best function. It was observed that carcinicultura wastewater can\'t be discarded without treatment, because they don\'t attend what is established in the brazilian legislation, due of BOD concentrations.
47

Avaliação de desempenho de lagoas de estabilização no tratamento de dejetos de suínos: aspectos microbiológicos / Performance valuation of stabilization ponds for swine wastewater treatment: microbiological aspects

Alves, Renato Vieira 25 March 2004 (has links)
Made available in DSpace on 2015-03-26T13:46:43Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1035711 bytes, checksum: 8bfda17a9052b539367681b5d54200ed (MD5) Previous issue date: 2004-03-25 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The development of the hog production in Brazil evidenced the problem of the treatment and destination of the swine manure, subject that until the 70 s it was not reason concern for. However, besides environmental consequences, the absence or treatment inadequacy can bring damages for the health, human or animal. Two different systems of stabilization ponds for swine wastewater treatment were monitored for, approximately, one year. One of them composed for three anaerobic ponds and one facultative pond (Farm A) and the other for an anaerobic reactor and a series of polishing ponds (Farm B). Pathogenics (Salmonella spp. and porcine parvovirus) and indicators (total coliforms, Escherichia coli, enterococci and Streptococcus spp) microrganisms were researched in the not treated effluent and in the effluent of each unit. Other six farms also had the feces of the herd evaluated, for the same parameters, in three samples of each property. Salmonella spp. was found in 40% of the samples (14/35), and, in the Farm B ponds system, it was identified until the effluent of the second anaerobic pond. 45% (9/20) of the samples were positive for parvovirus. Statistically significant differences were not observed between the coliforms and streptococci concentrations in the samples of not treated effluent, the same was found in the samples of swine feces. In both monitored systems, the removal efficiency was below the expected. For the system of Farm A, the efficiency was close to 99,9% (3log10) with a hidraulic detention time of 52,6 days. For the other system, the efficiency was among 90-99% (1-2 log10) with a hydraulic detention time of 122,5 days. In contrast to the performance of the systems as a whole, the anaerobic ponds revealed good efficiency of bacterial removal. However, in the event of the optional ponds - of polishing - the results indicate that should have better conception of the system so that these indeed accomplish the expected performance in the bacterial removal. Regression studies among the volumetric loading rates of Biochemical Oxygen Demand (BOD), Chemical Oxygen Demands (COD) and volatile solids and the removal efficiency of the four indicative organisms was accomplished, revealing, generally, excellent association among the variables. / O desenvolvimento da suinocultura no país evidenciou o problema do tratamento e da destinação dos dejetos de suínos, questão que até a década de 70 não era motivo de preocupação. Porém, além de conseqüências ambientais, a ausência ou inadequação de tratamento pode trazer prejuízos para a saúde, humana ou animal. Dois diferentes sistemas de lagoas de estabilização para tratamento de dejetos de suínos foram monitorados por, aproximadamente, um ano. Um deles composto por três lagoas anaeróbias e uma facultativa (Granja A) e o outro por um reator anaeróbio e uma série de lagoas de polimento (Granja B). Pesquisaram-se microrganismos patogênicos (Salmonella spp. e parvovírus suíno) e indicadores (coliformes totais, Escherichia coli, enterococos e Streptococcus spp) no dejeto bruto e no efluente da cada unidade de tratamento. Outras seis granjas também tiveram as fezes dos suínos avaliadas para os mesmos parâmetros, em três amostras de cada propriedade. Salmonella spp. foi encontrada em 40% das amostras (14/35), sendo que, no sistema de lagoas da Granja B, foi identificada até o efluente da segunda lagoa anaeróbia. Os resultados para parvovírus foram positivos em 45% das amostras (9/20). Não foram observadas diferenças estatisticamente significativas entre as concentrações de coliformes e estreptococos no dejeto bruto, mesmo resultado encontrado nas amostras de fezes de suínos. Em ambos os sistemas monitorados, a eficiência de remoção dos indicadores esteve abaixo do esperado. Para o sistema da Granja A, a eficiência foi próxima de 99,9% (3log10) com um tempo de detenção hidráulica (TDH) de 52,6 dias. Para o outro sistema, da Granja B, a eficiência foi entre 90-99% (1-2 log10) para TDH de 122,5 dias. Em contraste ao desempenho global dos sistemas, as lagoas anaeróbias, individualmente, revelaram boa eficiência de remoção bacteriana. Já no caso das lagoas facultativas de polimento os resultados indicam que deve haver melhor concepção do sistema para que estas efetivamente cumpram o papel esperado na remoção bacteriana. Estudos de regressão entre as taxas volumétricas de Demanda Bioquímica de Oxigênio (DBO), Demanda Química de Oxigênio (DQO) e Sólidos Voláteis (SV) e a eficiência de remoção dos quatro organismos indicadores foram realizados, revelando, em geral, excelente associação entre as variáveis.
48

Decaimento bacteriano em lagoas de estabiliza??o no Nordeste brasileiro

Torres, Dayana Melo 17 June 2011 (has links)
Made available in DSpace on 2014-12-17T15:03:27Z (GMT). No. of bitstreams: 1 DayanaMT_DISSERT.pdf: 5461193 bytes, checksum: e14ad35e988326c6b2deb98ea1ef274e (MD5) Previous issue date: 2011-06-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay. / Lagoas de estabiliza??o consistem no sistema de tratamento de esgotos mais utilizado no Rio Grande do Norte (RN), Brasil, correspondendo a cerca de 90% de todos os sistemas. As bact?rias fecais s?o removidas principalmente nas lagoas facultativas e de matura??o. Muitos fatores influenciam no decaimento de bact?rias, como: os n?veis de pH e OD, temperatura, intensidade luminosa, TDH e disponibilidade de alimento. A taxa de decaimento bacteriano (Kb) ? calculada a partir de muitas vari?veis, mas o regime hidr?ulico possui significativa influ?ncia na remo??o de microorganismos, sendo o de fluxo disperso o que melhor caracteriza uma lagoa de estabiliza??o. Todavia, alguns autores elaboraram equa??es para o Kb conforme o regime de mistura completa. Essa pesquisa teve como objetivo avaliar o decaimento bacteriano de coliformes termotolerantes e Enterococcus sp. em lagoas de estabiliza??o destinadas ao tratamento de esgotos dom?sticos, em escala real, no RN. Todos os sistemas avaliados possuem tratamento preliminar, uma lagoa facultativa (LF), seguida de duas de matura??o (LM1 e LM2). Os par?metros avaliados foram: temperatura, pH, OD, DBO5, DQO, coliformes termotolerantes, Enterococcus sp., clorofila a, s?lidos em suspens?o totais, fixos e vol?teis. N?o foram identificadas diferen?as significativas entre os valores de pH, OD e temperatura nas lagoas, exceto para os sistemas mais novos, j? que eles possuem baixas vaz?es e cargas hidr?ulicas. A remo??o de mat?ria org?nica nos sistemas de tratamento foi baixa, cerca de 70%, e praticamente todas est?o com sobrecarga org?nica e com problemas operacionais. As remo??es bacterianas tamb?m foram baixas, com m?dia para as LF de 96% para coliformes termotolerantes, e de 98% para Enterococcus sp.; nas LM1 obteve-se remo??o para coliformes termotolerantes de 71%, e para Enterococcus sp. de 81%; e, nas LM2 a efici?ncia foi de 69% para coliformes termotolerantes e de 68% para Enterococcus sp. A equa??o proposta por Von Sperling (1999), segundo o regime de fluxo disperso, foi a que gerou valores de Kb emp?ricos mais aproximados dos valores de Kb calculados a partir de dados reais. Em m?dia, o Kb calculado com base nos dados reais para coliformes termotolerantes nas LF foi de 0,31 d-1, e em ambas as lagoas de matura??o foram de 0,35 d-1. Para Enterococcus sp. a m?dia nas LF foi de 0,40 d-1, nas LM1 foi igual a 0,55 d-1, e nas LM2 de 0,58 d-1. Esses resultados tamb?m demonstraram que os Kb obtidos em sistemas em escala real s?o menores do que os verificados em lagoas em escala piloto. Al?m disso, pode-se afirmar que a equa??o proposta por Marais (1974), segundo o regime de mistura completa, superestima o Kb. Os resultados dos Kb calculados indicaram que os coliformes termotolerantes s?o mais resistentes ?s condi??es adversas presentes em lagoas de estabiliza??o do que os Enterococcus sp., sendo, portanto, um indicador microbiol?gico mais eficiente e seguro. Os fatores de significativa interven??o na taxa de decaimento bacteriano foram as concentra??es de DQO, a carga org?nica e o TDH. As poucas rela??es existentes entre Kb com pH, OD e temperatura n?o foram estatisticamente significativas. Por fim, conclui-se que ? fundamental a opera??o e manuten??o corretas, pois a n?o realiza??o dessas atividades consiste em um dos principais fatores que contribuem para as baixas taxas de decaimento bacteriano.
49

Remo??o de mat?ria org?nica em sistemas de lagoas de estabiliza??o no Nordeste brasileiro

Silva, Od?nia Alves de Lima 24 October 2011 (has links)
Made available in DSpace on 2014-12-17T15:03:28Z (GMT). No. of bitstreams: 1 OdeniaALS_DISSERT.pdf: 3500566 bytes, checksum: bcbbd86a88f2dade1ad704684123cb31 (MD5) Previous issue date: 2011-10-24 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject / Lagoa de estabiliza??o ? a principal tecnologia utilizada para tratamento de esgotos dom?sticos no Nordeste brasileiro, devido ao menor custo de implanta??o, opera??o e manuten??o, quando comparada com outras tecnologias. A maioria dos sistemas de lagoas de estabiliza??o est? em opera??o h? bastante tempo, em m?dia 10 anos de opera??o, recebem altas cargas org?nicas e n?o apresentam boas efici?ncias de remo??o dos principais par?metros a qual foram projetadas. Portanto, faz-se necess?rio um trabalho que quantifique a efici?ncia atual desses sistemas. O presente estudo avaliou a biodegradabilidade da mat?ria org?nica no esgoto bruto, a remo??o da mat?ria org?nica nos reatores e a determina??o da constante cin?tica de remo??o de mat?ria org?nica (k), tanto nos reatores quanto no esgoto bruto, baseadas nas an?lises feitas em laborat?rio e atrav?s dos m?todos matem?ticos propostos pela literatura, em nove sistemas de lagoas de estabiliza??o, no Rio Grande do Norte. Em rela??o ? cin?tica de degrada??o em lagoas de estabiliza??o, observou-se que muitos trabalhos publicados na literatura foram obtidos em sistemas em escala piloto, o que muitas vezes, devido ? a??o de fatores externos, tais como vento e temperatura, esses n?o podem ser considerados como refer?ncia na an?lise da constante cin?tica K, por isso a necessidade de se pesquisar mais em sistemas de escala real. Essa pesquisa teve tr?s fases distintas e simult?neas: monitora??o de rotina, estudo do ciclo di?rio e a determina??o da constante cin?tica de degrada??o da mat?ria org?nica (K). O monitoramento mostrou que as efici?ncias de remo??o de mat?ria org?nica, na maioria dos sistemas, estavam abaixo do sugerido pela literatura, sendo as melhores efici?ncias da ordem de 76% (DBO) e de 72% (DQO) e as piores da ordem de 48% (DBO) e 55% (DQO). O calculo do K no esgoto bruto (Ke) mostrou-se dentro da faixa de varia??o prevista na literatura (0,35 a 0,60 dia-1). J? para os resultados obtidos para K nos reatores (Kr), verificaram-se valores bem abaixo do preconizado pela literatura (0,25 a 0,40 d-1 para mistura completa e 0,13 a 0,17 d-1 para fluxo disperso), em conson?ncia com as sobrecargas org?nicas a que os sistemas est?o sujeitos
50

Emprego de biofiltro de pedra para remo??o de microalgas e s?lidos suspensos de efluentes de lagoas de estabiliza??o

Queiroz, Mois?s Andrade de Farias 28 February 2014 (has links)
Made available in DSpace on 2014-12-17T15:03:33Z (GMT). No. of bitstreams: 1 MoisesAFQ_DISSERT.pdf: 1322817 bytes, checksum: d69733a37de991cb265f0cf0939bee27 (MD5) Previous issue date: 2014-02-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds / A pesquisa avaliou a remo??o das microalgas produzidas em um sistema de lagoas de estabiliza??o utilizando biofiltros como p?s-tratamento, al?m de caracterizar os efluentes de lagoas de estabiliza??o e dos filtros no tocante ?s concentra??es de biomassa algal (clorofila a e s?lidos suspensos), mat?ria org?nica (DBO e DQO), ortofosfato, f?sforo total, pH e oxig?nio dissolvido, e buscou correlacionar os par?metros f?sico-qu?micos com a clorofila a . Foi realizada na ETE Ponta Negra que ? constitu?da por tr?s lagoas de estabiliza??o, sendo uma lagoa facultativa prim?ria e duas de matura??o. Para a remo??o das algas, foram utilizados dois biofiltros submersos: o filtro FLF -alimentado com efluente da lagoa facultativa; e o filtro FLM - alimentado com efluente da segunda lagoa de matura??o. O material de enchimento de ambos os filtros foi predominantemente brita n? 2, apesar de conter por??es de brita n? 1 e n? 3. As condi??es operacionais dos filtros eram p?ssimas, pois estavam h? quase 10 anos sem manuten??o, sem limpeza ou remo??o do lodo desde a ?poca da constru??o, podendo parte do material de enchimento estar colmatado. Apesar das condi??es operacionais prec?rias foram obtidos resultados satisfat?rios, em n?vel de p?s-tratamento. As efici?ncias de remo??o em rela??o ? DBO e DQO foram de 7 e 25% no FLF e 9 e 19% no FLM, respectivamente. Em rela??o aos SST as efici?ncias no FLF e FLM foram de 37 e 20%, respectivamente. Quanto ? remo??o de clorofila a , a efici?ncia no FLF foi de 44% e no FLM foi de 40%. Houve o consumo de 50% do oxig?nio dissolvido, em m?dia, no interior dos filtros. Foram realizados dois perfis nos filtros, e foi poss?vel concluir que as varia??es ao longo do dia n?o foram estatisticamente significativas, e que, independentemente do hor?rio da coleta, teriam a mesma representatividade ao comparar com o hor?rio da coleta da pesquisa (7 horas da manh?) e a m?dia di?ria, embora as varia??es pontuais ao longo do dia tenham se mostrado expressivas. Outra importante observa??o foi que as correla??es entre Clorofila a e SST foram maiores e mais significativas nos efluentes dos filtros do que nos efluentes das lagoas

Page generated in 0.1418 seconds