• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 336
  • 86
  • 52
  • 37
  • 21
  • 18
  • 14
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • Tagged with
  • 1168
  • 506
  • 236
  • 225
  • 221
  • 181
  • 177
  • 157
  • 152
  • 118
  • 109
  • 101
  • 97
  • 94
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Avaliação do efeito antibacteriano e da citotoxicidade de um adesivo com nanopartículas de prata e sua resistência de união à dentina associado ao uso de nanopartículas de hidroxiapatita / Evaluation of antibacterial effect, cytotoxicity of adhesive modified by silver nanoparticles, and bond strength to dentin when associated to the use of hydroxyapatite nanoparticles

Aguiar, Juliana Dias 31 January 2019 (has links)
O desenvolvimento de adesivos bioativos mostra-se como uma alternativa interessante para agregar benefícios aos novos materiais. O objetivo do estudo foi sintetizar nanopartículas de prata (NAg) e de hidroxiapatita (NHA), avaliar sua influencia no efeito antibacteriano, citotoxicidade de um adesivo com NAg e sua resistência de união à dentina associado ao uso de NHA. As nanopartículas foram caracterizadas por fluorescência de raio x por reflexão total (TRXF), difratometria de raio x (DRX), microscopia eletrônica de transmissão (TEM) e espalhamento de luz visível (DLS). O sistema Scotchbond Multi-Purpose (SBMP) foi modificado com adição de 0,05% e 0,1% de NAg no primer e no bond. Molares humanos foram restaurados com o sistema adesivo modificado após o pre-tratamento da dentina com suspensão aquosa de NHA a 0,5% e 1% para realização do ensaio de resistência de união imediata (24h) e após 1 ano de envelhecimento. A interface adesiva foi caracterizada por Microscopia Confocal Raman (MCR). Para mensurar o efeito antibacteriano (S.mutans) do adesivo com NAg foi realizado o ensaio de difusão em ágar com template e contagem de Unidades Formadoras de Colônias (UFC). A citotoxicidade foi avaliada com uso de células tronco da polpa dentária (DPSCs) em contato com adesivos não polimerizados e polimerizados em diferentes concentrações de meio condicionado (0% 25%, 75% e 100%). Foram produzidas NAg esféricas, com estrutura cúbica de face centrada, e com 16 nm de diâmetro médio. As NHA exibiram estrutura prismática com tamanho médio de 79,4 nm. O adesivo com NAg e o tratamento da dentina com NHA não afetaram a resistência de união imediata ou após 1 ano de envelhecimento, e as interfaces adesivas mostraram-se íntegras. Os adesivos modificados por NAg exibiram citotoxicidade similar ao adesivo controle e maior efeito antibacteriano. Os adesivos com adição de NAg são promissores quanto à obtenção de um material bioativo antimicrobiano que não altera a resistência de união ou a biocompatibilidade. / The development of bioactive adhesives is shown an interesting alternative to add benefits to the new materials. The aim of the study was to synthesize silver nanoparticles (NAg) and hydroxyapatite (NHA) and to evaluate their influence on the bond strength, antimicrobial effect, and biomaterials cytotoxicity. The nanoparticles were characterized by x-ray fluorescence by total reflection (TRXF), x-ray diffractometry (XRD), transmission electron microscopy (TEM) and visible light scattering (DLS). The Scotchbond Multi-Purpose system (SBMP) was modified with 0.05% and 0.1% silver in the primer and bond. Human molars were restored with the modified adhesive after pre-treatment of dentin with 0.5% and 1% NHA for the immediate bond strength test (24h), and after 1 year of aging. The adhesive interface was characterized by Confocal Raman Microscopy (MCR). To measure the antibacterial effect (S.mutans) of the adhesive with NAg, the agar diffusion assay with template was performed and counting of Colony Forming Units (UFC). In order to evaluate the cytotoxicity, dental pulp stem cells (DPSCs) were used in contact with unpolymerized and polymerized adhesives in different concentrations of conditioned medium (0% 25%, 75% and 100%). Spherical NAg, with a cubic face centered structure, and 16 nm in diameter were produced. The NHA exhibited a prismatic structure with approximately 79.4 nm. The adhesive with NAg and the treatment of dentin with NHA did not affect the bond strength immediately or after 1 year of aging, and the adhesive interfaces were shown to be intact. NAg-modified adhesives exhibited cytotoxicity similar to the control adhesive and higher antibacterial effect. The adhesives with NAg addition are promising in obtaining a bioactive antimicrobial material that does not alter the bond strength or the biocompatibility.
202

Caracterização de um aço baixo carbono microligado ao vanádio utilizado na fabricação de componentes mecânicos / Characterization of a low carbon vanadium microalloyed steel used in the manufacture of mechanical components

Moraes Junior, Odilon de 05 April 2019 (has links)
Os aços microligados representam, cada vez mais, uma parcela significativa de produção das usinas siderúrgicas para aplicações nos mais variados segmentos industriais tais como o automotivo, petróleo e gás, construção civil e agronegócio. A característica principal desses aços é a sua elevada resistência mecânica, aliada à boa tenacidade, ductilidade e soldabilidade; o que vem sendo obtido pela utilização de composições químicas específicas com teores baixos de carbono e de microligantes que conferem essas características a esses aços. Os microligantes utilizados são os mais variados, mas principalmente destaca-se a utilização do vanádio, nióbio, titânio, cobre, manganês, cromo, alumínio e nitrogênio. No presente trabalho foram estudadas as propriedades mecânicas de um aço microligado ao vanádio com 0,25%V e um aço AISI 1020. O aço microligado apresentou LRT, LE, alongamento e estricção de, respectivamente, 735,29 MPa, 559,07 MPa, 22,7% e 63,29%. O aço AISI 1020 apresentou, respectivamente, 437,42 MPa, 268,71MPa, 32,92% e 67,15%. O aço microligado apresentou propriedade mecânica superior à do aço AISI 1020 e ductilidade equivalente. Os resultados de impacto Charpy nas temperaturas de 23 °C, -20 °C e -40 °C foram, para o aço microligado, respectivamente de, 33,83 J, 12,41 J, e 6,54 J, e para aço AISI 1020 33,18 J, 5,07 J e 3,04 J, respectivamente. Observa-se tenacidade superior do aço microligado, quando comparado com o aço AISI 1020. O ensaio revelou microestruturas refinadas em ambos os aços, e tamanho de grão de 18μm n° 8 ASTM E 112 e de 25 μm n° 7 para o aço microligado e para o AISI 1020, respectivamente. Os testes eletroquímicos realizados em uma solução aquosa 3,5% em peso de NaCl revelaram que o aço microligado apresentou formação de camada passiva, e mostrou-se menos resistente à corrosão. / Microalloyed steels are representing significant portion and increasingly steelmakers production and they are being applied to several industrial market segments such as automotive, oil and gas, civil construction and agribusiness. Its main characteristics are the superior tensile strength, toughness, ductility and good weldability. These properties are obtained through specific chemical compositions as low carbon and microalloying elements contents. Several microalloying elements can be used but some of them need to be mentioned such as vanadium, niobium, titanium, cooper, manganese, chromium, aluminum and nitrogen. In this work, the mechanical properties of a vanadium microalloyed and AISI 1020 steels were studied and compared. The microalloyed steel presented LRT, LE, elongation and toughness values of, respectively, 735.29 MPa, 559.07 MPa, 22.7% and 63,29%. AISI 1020 presented, respectively, 437.41 MPa, 268.70 MPa, 32.92% and 67.15%. The microalloyed steel presented mechanical properties superior to AISI 1020 and equivalent ductility. The results of the Charpy impact tests at the temperatures of 23 ° C, -20 ° C and -40 ° C were 33.83 J, 12.41 J, 6.54 J for the microalloyed steel, and for AISI 1020 steel the values were 33,18 J, 5.07 J and 3.04 J, respectively. The superior toughness of the microalloyed steel is observed when compared to the AISI 1020 steel. The metallographic examination showed fine grain microstructures ASTM E 112 No.8 and 7.for the microalloyed and for the AISI 1020, respectively. The electrochemical tests carried out in a 3.5 wt% NaCl aqueous solution showed that the microalloyed steel is less resistant to corrosion, and that a passive layer was formed on its surface.
203

\"Sistemas adesivos autocondicionantes aplicados no esmalte: avaliação da resistência de união, morfologia de interface e padrão de condicionamento em função do tratamento e substrato\" / Self etching primers applied in the enamel: adhesive bond strength, interface morphology, etch pattern in relation the treatment and substrate

Lima, Janaina de Oliveira 08 February 2007 (has links)
Este estudo teve como objetivo verificar a possibilidade de utilizar o esmalte bovino, em teste resistência de união, substituindo o esmalte humano, bem como, analisar a resistência de união, morfologia de interface e padrão de condicionamento de sistemas adesivos autocondicionantes aplicados ao esmalte intacto e asperizado. Foram usados 40 dentes humanos e 40 dentes bovinos. Cada dente foi dividido em quatro regiões, de maneira a permitir a obtenção dos corpos-de-prova de todas as condições experimentais. Três sistemas adesivos autocondicionates; Clearfil Protect Bond (Kuraray Medical inc), Adper Prompt L-Pop (3M-ESPE), i Bond (Heraeus-Kulzer) foram testados, sendo utilizado um sistema de condicionamento total, Excite (Ivoclar-Vivadent), como controle positivo. A resina Tetric Ceram foi utilizada para a confecção dos corpos-de-prova, para resistência de união e amostras de microscopia eletrônica de varredura (MEV). As médias de resistência de união foram avaliadas por análise de variância e Tukey. Não houve diferença estatística, na resistência de união, entre os substratos, embora, as médias em esmalte humano tenham sido mais altas. A interação tripla; sistema Adesivo x Tratamento x Esmalte, também não foi significante, no entanto, manteve-se a tendência dos autocondicionantes de passo único apresentar as menores médias de resistência de união, principalmente no esmalte intacto. Houve diferença estatística para o fator sistema adesivo, sendo que o menor resultado foi obtido com o adesivo i Bond, na interação sistema adesivo x tratamento, a menor média também foi obtida pelo adesivo i Bond, quando aplicado ao esmalte intacto. O fator tratamento foi significante, sendo que, na variável de esmalte asperizado constatou-se a maior média de resistência de união, evidenciando que a asperização da superfície de esmalte, quando um sistema adesivo autocondicionante é aplicado no esmalte, constitui um passo operatório essencial. As imagens de MEV evidenciaram maior porosidade no dente bovino, independente do sistema adesivo utilizado e maior descalcificação do esmalte, tanto asperizado, quanto intacto, para os adesivos Excite e Adper Prompt L-Pop. Em relação à interface observou-se, que a camada de adesivo, no esmalte asperizado, tanto humano, quanto bovino, mostrou-se mais espessa, não importando o tipo de sistema adesivo; autocondicionante ou convencional. Os prismas de esmalte, no substrato bovino, mostraram um arranjo diferenciado, do observado no esmalte humano, porém esta diferença não promoveu alteração na resistência de união, visto que, não houve diferença estatística entre os substratos. Assim na impossibilidade de se obter esmalte humano, para testes de microtração, a utilização do esmalte bovino é viável. / The aim of this study was to verify the possibility in use the bovine enamel, as a substitute to human enamel, in the microtensile bond strength test, as well as analyze the bond strength, interface morphology and etch pattern of the self etching primers (SEP) applied in the cut and uncut, bovine and human, enamel. For this 40 human teeth and 40 bovine teeth were used, each tooth was divided in four halves to obtain all experimental conditions in the same tooth. Three SEP; Clearfil Protect Bond (CPB) (Kuraray Medical Inc), Adper Prompt L-Pop (LP) (3M-ESPE), i Bond (IB) (Heraeus-Kulzer) were tested, using a conventional adhesive system, Excite (EX) (Ivoclar Vivadent), as a positive control. A bulk of composite resin, Tetric Ceram (Ivoclar Vivadent), was build up for the specimens of microtensile test and SEM. In all above trials, some specimens were randomly selected and prepared for SEM. The data collected was submitted for statistical analyze ANOVA and Tukey test. It was possible to verify that there were no statistically differences between the substrate and triple interaction Adhesive Systems x Substrate x Treatment, but in the booth conditions, the SEP, i Bond, showed the lowest means, as same as, all means in bovine enamel were lowest than in human enamel. There were statistically differences between the systems adhesives and for treatment, cut and uncut. For adhesive systems the lowest value was observed for i Bond, in booth substrate and treatment. In the treatment conditions the greater means were observed in the cut enamel, showing that the cutting enamel is essential condition, to improve the bond strength of SEP, applied in the enamel. The SEM images, for etch pattern showed that in the bovine enamel the porosity was more thickness, for all adhesives and cut and uncut treatment. It was possible to verify, trough SEM of morphology interface, that the all adhesives in cut enamel, had adhesive layer more thickness, as and exception was the SEP, I Bond, that showed adhesive layers thinner. The bovine enamel showed a different arrangement for prisms that showed in the human enamel. We conclude that when the use of human enamel, in the microtensile test, is unviable, it is possible to use the bovine enamel as a substrate.
204

Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element Analysis

Miyashita, Elcio Ricardo 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
205

Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layer

Lobo, Tamile Rocha da Silva 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
206

Ligaduras ortodônticas elastoméricas estéticas: alteração de cor, ultraestrutura da superfície (MEV) e propriedade elástica após uso de dentifrício clareador (estudo in vivo) / Esthetic orthodontic elastic ligatures: color change, ultra-structural surface (SEM) and elastic property after the use of whitening dentifrice (an in vivo study)

Matos, Leonardo Gontijo 27 July 2017 (has links)
O objetivo desse estudo foi comparar o desempenho de ligaduras ortodônticas estéticas de 4 marcas comerciais, após 30 dias na cavidade bucal, com o uso de dentifrício clareador e convencional para avaliar: alteração de cor por meio da espectrofotometria; a ultraestrutura da superfície por meio da Microscopia Eletrônica de Varredura (MEV); propriedade elástica por meio do teste de tração. Foram avaliadas as ligaduras seguintes marcas comerciais: American Orthodontics, 3M Unitek, Orthotechnology e Morelli Ortodontia. Foram selecionados, após o cálculo amostral, 20 pacientes que atenderam aos critérios de inclusão. Os pacientes receberam, de forma aleatória, com o auxílio do acessório Shooter (TP Orthodontics, La Porte, IN, EUA) ligaduras nos elementos 13, 23, 33 e 43; 32, 31, 41 e 42. No mesmo dia receberam dentifrício clareador Colgate Luminous White (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brasil) que foi usado por 30 dias (grupo experimental). Após esse período as ligaduras foram removidas, armazenadas (em saliva artificial) e, imediatamente submetidas aos testes. Os pacientes receberam, então, dentifrício convencional Colgate Máxima Proteção Anti-cáries (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brasil) (grupo controle). Após 30 dias, foram removidas, armazenadas e submetidas aos ensaios. As ligaduras inseridas nos bráquetes dos caninos foram avaliadas para alteração de cor pelo espectrofotômetro (Vita Easyshade Zahnfabrik, Bad Säckingen, Alemanha). Em seguida, as ligaduras, de cada marca, que apresentaram maior e menor variação de cor com o dentifrício clareador e convencional, bem como ligaduras novas, foram submetidas à avaliação qualitativa com a visualização pelo Microscópio Eletrônico de Varredura (EVO 50, Carl Zeiss, Cambridge, Inglaterra). As ligaduras que estavam inseridas nos bráquetes incisivos inferiores foram submetidas ao teste de tração pela Máquina de Ensaio Mecânico Universal (EMIC DL 2000, São José dos Pinhais, PR, Brasil). Os achados foram submetidos à análise estatística ANOVA e ao teste complementar de Duncan em um nível de significância de 5%. Os resultados mostraram que o dentifrício clareador não conseguiu efetivamente manter a estabilidade de cor das ligaduras ortodônticas estéticas. O valor final para o &Delta;E (variação total de cor) para todas as marcas foi > 3,3 o que indica uma alteração clinicamente perceptível pelo olho humano e que sinaliza a reposição do material por razões estéticas. Em relação à MEV as imagens obtidas foram heterogêneas e não permitiram caracterizar um padrão para um ou outro dentifrício. No que se refere ao teste de tração, houve melhor desempenho para as marcas 3M Unitek e American Orthodontics. O tipo de dentifrício, clareador ou convencional, não alterou a propriedade elástica entre as marcas estudadas. Pode-se concluir, pela presente pesquisa, que o dentifrício clareador não foi capaz de alterar a estabilidade de cor nas 4 marcas avaliadas por um período de 30 dias. A avaliação qualitativa pela MEV não permitiu concluir se a abrasividade do dentifrício clareador trouxe danos ou injurias à superfície das ligaduras. Apesar disso, o seu uso não alterou a propriedade elástica das mesmas. / The objective of this study was to compare the performance of aesthetic orthodontic ligatures/modules of 4 commercial brands, after 30 days in the oral cavity, with the use of conventional and whitening dentifrice to evaluate: color change by spectrophotometry; the ultrastructure of the surface by Scanning Electron Microscopy (SEM); elastic property by the tensile test. The following brands were evaluated: American Orthodontics, 3M Unitek, Orthotechnology and Morelli Orthodontics. Twenty patients who were included in the inclusion criteria were selected after sample calculation. Patients received, at random, with the aid of the Shooter accessory (TP Orthodontics, La Porte, IN, USA) ligatures on elements 13, 23, 33, 43, 32, 31, 41 e 42 and whitening dentifrice Colgate Luminous White (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brazil), which was used for 30 days (test group). After this period, the ligatures were removed, stored (in artificial saliva) and immediately submitted to the tests. Patients were then given conventional toothpaste Colgate Maximum Anti-caries Protection (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brazil). This was the control group. Once again, after 30 days, the modules were removed, stored and submitted to assays. Ligatures inserted into the canine brackets were evaluated by the spectrophotometer (Vita Easyshade Zahnfabrik, Bad Säckingen, Germany) to evaluate the color change. After this step, the ligatures of each brand, which presented greater and lesser color variation, both with the whitening dentifrice as well as the conventional one, and new ligatures, were selected for qualitative evaluation with the visualization by the Scanning Electron Microscope (EVO 50, Carl Zeiss, Cambridge, England). The ligatures that were inserted in the lower incisor brackets were subjected to the tensile test by the Universal Mechanical Testing Machine (EMIC DL 2000, São José dos Pinhais, PR, Brazil). The findings were submitted to ANOVA statistical analysis and Duncan\'s complementary test at a significance level of 5%. The results showed that the whitening dentifrice failed to effectively improve the color stability of aesthetic orthodontic ligatures. The final value for &Delta;E (total color change) for all brands was > 3.3 which indicates a change clinically perceptible by the human eye and signaling the replacement of the material for aesthetic reasons. In relation to the SEM the images obtained were heterogeneous and did not allow to characterize a standard for one or the other dentifrice. Regarding the tensile test, there was better performance for the brands 3M Unitek and American Orthodontics. The type of dentifrice, whitening or conventional did not alter the elastic property between the brands studied. It can be concluded from the present research that the whitening dentifrice was not able to change the color stability in the 4 brands evaluated for a period of 30 days. The qualitative evaluation by SEM did not allow the conclusion that the abrasiveness of the whitening dentifrice caused damage to the surface of the ligatures. Despite this, their use did not alter their elastic property.
207

Adesão à superfície de esmalte clareado: avaliação in vitro por microtração / Adhesion to the bleached enamel surface: in vitro assessment through microtensile

Lago, Andréa Dias Neves 03 June 2009 (has links)
O clareamento e os procedimentos adesivos são soluções muito utilizadas na Odontologia atual. Assim, o objetivo deste trabalho foi avaliar, in vitro, a resistência adesiva ao esmalte clareado através do ensaio mecânico de microtração. Dois sistemas adesivos autocondicionantes (Clearfil SE Bond - Kuraray e Adper Prompt LPop - 3M Espe) e um adesivo convencional (Adper Single Bond 2 - 3M Espe) foram aplicados imediatamente, 7 e 14 dias após o clareamento com peróxido de hidrogênio a 35% (Whiteness HP - FGM) ao esmalte. Foram utilizados 60 dentes bovinos que tiveram a superfície de esmalte planificada e em seguida divididos em 12 grupos (9 experimentais e 3 controles) de acordo com o adesivo empregado e o intervalo entre o clareamento e os procedimentos adesivos. O ensaio de microtração foi realizado 24 h após a confecção das restaurações e a área de fratura foi avaliada através da microscopia eletrônica de varredura. Houve redução significativa da resistência adesiva nos dentes restaurados imediatamente após o clareamento com todos os adesivos utilizados. Após 7 e 14 dias do término do clareamento, os valores de resistência adesiva se igualaram e foram semelhantes aos valores dos grupos controles dos respectivos sistemas adesivos empregados. O adesivo Adper Single Bond 2 apresentou os maiores valores de resistência adesiva e o Adper Prompt L Pop os mais baixos. Houve predominância de fraturas adesivas e mistas em todos os grupos. / Bleaching and adhesive proceedings are solutions much used in current Dentistry. Thus, this work aimed at assessing, in vitro, the adhesive resistance to bleached enamel through the microtensile mechanical trial. Two self-etch adhesive systems (Clearfil SE Bond - Kuraray and Adper Prompt L-Pop - 3M Espe) and a conventional adhesive (Adper Single Bond 2 - 3M Espe) were immediately employed, 7 and 14 days after bleaching with hydrogen peroxide at 35% (Whiteness HP - FGM) in the enamel. 60 bovine teeth were used, which had the enamel surface planned and following randomly divided into 12 groups (9 experimental and 3 controls) according to the employed adhesive and to the interval between the bleaching ending and the adhesive proceedings. The microtensile trial was accomplished 24 hours after the confection of the tooth fillings and the fracture area was assessed through scanning electronic microscopy. There was significant reduction of the adhesive resistance in the filled teeth immediately after bleaching with all employed adhesives. After 7 and 14 days of the bleaching ending, the adhesive resistance values were equated and were similar to the values of the control groups and to the respective adhesive systems employed. The Adper Single Bond 2 adhesive presented the highest adhesive resistance values and the Adper Prompt L-Pop presented the lowest ones. There was predominance of adhesive and mixed factures in all groups.
208

Resistência à tração entre componentes de pilar híbrido Conexão® submetido a teste de fadiga termomecânica / Tension strength between the two pieces of the hybrid abutment Conexão® after thermomechanical fatigue test

Bonachela, Clara Fassoni 21 September 2018 (has links)
Os pilares de próteses sobre implantes são determinantes para o sucesso final da restauração. Dentre os mais variados disponíveis no mercado, os pilares híbridos são uma proposta atual que propõe associar otimização da estética com performance biomecânica de qualidade à longo prazo. Sendo assim, o objetivo desse estudo foi verificar a resistência à tração entre os componentes do pilar híbrido parafusado Precision Link® (Conexão®) após ensaio de fadiga térmica e mecânica, através de uma metodologia inovadora proposta pelos autores. Foram utilizados 33 Conjuntos Precision Link 3,5 NP + Coping de Zircônia Base para Acrescentar 3,5 (Conexão), distribuídos em 3 grupos de 11 espécimes, nomeados de acordo com o número de ciclos mecânicos aos quais foram submetidos durante o teste de fadiga (Grupo Controle [G CONTROLE], Grupo de 240 000 ciclos [G1] e Grupo de 480 000 ciclos [G2]). Após o ensaio de fadiga termomecânica, os pilares foram submetidos a teste de tração, por meio de um dispositivo desenvolvido exclusivamente para esse trabalho, adaptado em uma máquina de ensaios universal. Os dados de resistência a tração foram submetidos à análise estatística através da análise de variância a 1 critério e Teste de Tukey para comparações individuais, mediante à qual foi identificada diferença estatisticamente significativa entre G1 e G CONTROLE e G1 e G2, tendo G1 demonstrado valores de resistência a tração menores que os outros grupos (Valores médios: G CONTROLE= 58,172 N, G1= 46,181 N, G2= 64,725 N). Pode-se concluir que a metodologia proposta para esse estudo, com o desenvolvimento de um dispositivo específico de tração é efetiva para identificar os valores de resistência à tração dos componentes de pilares híbridos parafusados Precision Link® (Conexão®) e a exposição aos ciclos termomecânicos testados no ensaio de fadiga influencia nos valores de tração entre os mesmos, primeiro diminuindo-os e depois aumentando-os de volta possivelmente por conta do fenômeno de degradação em baixa temperatura nos componentes de zircônia. / Implant abutments have a key role in the success of dental reabilitations. Among other options, hybrid abutments are a new option that can associate esthetic achievements with efficient long-term biomechanical performance. The purpose of this study was to verify the tension strenght between the components of the screw-retained hybrid abutment Precision Link® (Conexão®) after thermomechanical fatigue test, using an innovative approach. Thirty-three samples of Precision Link (d)3,5 NP + Zirconia Coping Add Base (d)3,5 (Conexão) were divided in three groups of eleven specimens each. The groups were divided by the number of mechanical cycles (Control Group [CONTROL G], Group of 240 000 cycles [G1] and Group of 480 000 cycles [G2]). After the thermomechanical fatigue test, the abutments were submitted to a tension strenght test in a specific device designed by the authors for this study. The referred device was coupled to an universal testing machine. Statistic analysis (ANOVA-1 e Tukey Test) showed G1 had statistical significative lower values of tension strenght than CONTROL G and also than G2. (Mean values: CONTROL G= 58,172 N, G1= 46,181 N, G2= 64,725 N) In conclusion, the methodology proposed for this study was effective in identifying the tension strenght values between the components of the screw-retained hybrid abutment Precision Link® (Conexão®). Also, the thermomechanical fatigue test influenced in the tension strenght values, first reducing the values of tension strenght, then increasing them back, by the transformation of phase of zirconia exposed to a wet environement.
209

Avaliação da interface de adesão à dentina humana de um sistema restaurador adesivo à base de silorano, em cavidades de Classe I, analisados por teste de microtração e microscopia óptica / Evaluation of the interface of a silorane based restorative system to dentin of Class I cavities by microtensile bond strength test and optical microscopy

Espinoza, Carlos Andrés Villavicencio 24 May 2013 (has links)
Este estudo teve como objetivo a análise da interface de adesão à dentina humana, de um sistema restaurador adesivo à base de silorano. Foram confeccionadas cavidades com 4mm X 3mm X 5mm em 40 molares humanos extraídos divididos em 4 grupos aleatoriamente: Grupos SB e SB-6m: sistema adesivo (Adper&#x2122; Single Bond) + resina composta (Filtek Z250); Grupos P90 e P90-6m: sistema adesivo (P90 System Adhesive) + resina composta (Filtek P90&#x2122;). Em todos os grupos, as restaurações foram inseridas em 4 incrementos oblíquos. Após a restauração, os dentes foram seccionados em fatias de 0,8mm de espessura em uma máquina de cortes com um disco de diamante. Uma fatia de cada dente foi separada aleatoriamente para análise em microscópio óptico para verificação de fendas na interface adesiva. As demais fatias foram seccionadas em palitos (0,8mm X 0,8mm) para os testes de microtração em uma máquina de ensaios universal EMIC. Os e dos grupos SB e P90 permaneceram em água deionizada em estufa a 370C por 24 horas e os grupos SB-6m e P90-6m permaneceram em água deionizada em estufa a 370C por um período de 6 meses. Os resultados de resistência de união foram submetidos à análise de variância a 2 critérios ANOVA e a presença de fendas internas foi analisada pelo testeChi-quadrado. Houve diferença estatisticamente significante na resistência de união entre os materiais (p>0,05) e tempo de armazenagem. Quanto à presença de fendas internas, foi evidenciada sua presença em todos os grupos, sem diferença etatisticamente significante entre eles (p>0,05). Conclui-se que não houve diferença entre os sistemas restauradores á base de Bis-GMA e de silorano os 2 períodos avaliados (24h e 6 meses). / This study aimed to analyse the adhesive interface to human dentin of a silorane based adhesive system. Cavities were fabricated with 4.0 mm X 3mm X 5mm in 40 extracted human molars randomly divided into 4 groups: Groups SB and SB-6m: adhesive system (Adper&#x2122; Single Bond) + composite (Filtek Z250); Groups P90 and P90- 6m: adhesive system (P90 System Adhesive) + composite (Filtek&#x2122; P90). In all groups, the restorations were inserted in 4 oblique increments. After 24 hours, teeth were sectioned buccolingually into 0.8mm slices with diamond saw. One slice of each tooth was randomly separated for microscope analysis. The other slices were sectioned into 0.8mm X0.8mm sticks for microtensile tests in a universal testing machine EMIC. Sticks of groups SB and P90 remained in deionized water at 370C C for 24 hours and sticks of groups SB-6m and P90-6m remained in deionized water at 370C for a period of six months. After storage period . The results of bond strength were analysed by Two-way ANOVA and the presence of internal gaps was analyzed by chi-square test. There was no significant difference in bond strength between materials (p> 0.05) and storage time. Regarding the presence of internal rifts, their presence was evident in all groups, with no statistically significant difference between them (p> .05).
210

"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.

Ramires-Romito, Ana Cláudia Durante 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers’ specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).

Page generated in 0.0565 seconds