• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Avaliação da inclinação axial dos dentes posteriores e sua respectiva morfologia alveolar nos diferentes padrões faciais: uma visão por meio da tomografia computadorizada de feixe cônico / Evaluation of the axial inclination of posterior teeth and their respective alveolar morphology in different facial patterns: a vision by cone beam computed tomography

Marcos Cezar Ferreira 26 August 2014 (has links)
O objetivo deste estudo foi comparar, por meio de tomografia computadorizada de feixe cônico, a inclinação axial dos dentes posteriores e a morfologia óssea alveolar mandibular entre indivíduos com diferentes padrões faciais. Para isso, foram utilizadas 58 tomografias de indivíduos maiores de 14 anos de idade não tratados ortodonticamente. Os indivíduos foram divididos em 3 grupos de acordo com o padrão facial avaliado pelo índice VERT de Ricketts: Grupo 1: composto por 18 indivíduos com padrão braquifacial, com idade média de 21,58 anos (d.p.=7,43); Grupo 2: composto por 23 indivíduos com padrão mesofacial, com idade média de 19,14 anos (d.p.=5,19); e Grupo 3: composto por 17 indivíduos com padrão dolicofacial, com idade média de 19,09 anos (d.p.=6,89). Foi realizada uma avaliação quantitativa das tábuas ósseas vestibular e lingual dos dentes pósteroinferiores, em tomografias de feixe cônico. As medidas utilizadas foram: altura do osso mandibular vestibular e lingual, largura mandibular cervical e média, inclinação mandibular, inclinação da face vestibular, largura do molar, angulação do molar e ângulo dente/osso. A comparação intergrupos foi realizada com a utilização do teste ANOVA a um critério de seleção e teste de Tukey quando necessário. Para verificar se existe correlação entre o padrão facial e as variáveis estudadas foi utilizado o teste de correlação de Pearson. Os resultados demonstraram que os indivíduos braquifaciais apresentaram uma menor inclinação mandibular quando comparados aos indivíduos mesofaciais e dolicofaciais. Houve diferença significante da altura mandibular vestibular entre os três grupos avaliados, sendo que esta foi menor no grupo braquifacial, intermediária no grupo mesofacial e maior no grupo dolicofacial. A altura mandibular lingual foi menor no grupo braquifacial em comparação aos grupos mesofacial e dolicofacial. A largura mandibular média foi maior nos indivíduos braquifaciais em relação aos mesofaciais. / The aim of this study was to compare, with cone beam computed tomography, the axial inclination of posterior teeth and mandibular alveolar bone morphology among individuals with different facial patterns. For this, 58 CT scans of untreated individuals orthodontically aged more than 14 years were used. The subjects were divided into 3 groups according to the facial pattern evaluated by the VERT index by Ricketts: Group 1 comprised 18 individuals with brachyfacial pattern, with a mean age of 21.58 years (s.d.=7.43); Group 2 comprised 23 individuals with mesofacial pattern, with a mean age of 19.14 years (s.d.=5.19); and Group 3 comprised 17 individuals with dolichofacial pattern, with a mean age of 19.09 years (s.d.=6.89). A quantitative assessment of the buccal and lingual bone plates of the mandibular posterior teeth were made in cone beam CT scans. The variables measured were: buccal and lingual mandibular height, cervical and middle mandibular width, mandibular inclination, inclination of the buccal surface, molar width, molar angle and tooth/bone angle. The intergroup comparison was performed by one-way ANOVA and Tukey test when necessary. To check whether there is a correlation between facial pattern and the variables studied, the Pearson correlation test was used. The results showed that the brachyfacial subjects had a smaller mandibular angle when compared to mesofacial and dolichofacial individuals. There was significant difference in the buccal mandibular height between the three groups, and this was smaller in the brachyfacial group, intermediate in the mesofacial group and larger in the dolichofacial group. Lingual mandibular height was smaller in brachyfacial group when compared to mesofacial and dolichofacial groups. The mean mandibular width was greater in brachyfacial than in mesofacial subjects.
222

Acur?cia em cirurgia ortogn?tica bimaxilar : avalia??o bidimensional e tridimensional

Scolari, Neimar 27 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2017-02-06T12:47:09Z No. of bitstreams: 1 DIS_NEIMAR_SCOLARI_COMPLETO.pdf: 1049949 bytes, checksum: 34c4eb21fb744a249998c3c238ee02e1 (MD5) / Made available in DSpace on 2017-02-06T12:47:09Z (GMT). No. of bitstreams: 1 DIS_NEIMAR_SCOLARI_COMPLETO.pdf: 1049949 bytes, checksum: 34c4eb21fb744a249998c3c238ee02e1 (MD5) Previous issue date: 2015-03-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Objective: to evaluate the accuracy and precision of manual assessment method of results achieved from lateral cephalograms of 20 skeletal class II and III subjects who have undergone bimaxillary orthognathic surgery, comparing it to the three-dimensional evaluation performed from Cone-Beam Computed Tomography (CBCT) in the pre and postoperative period (6 months) in surgeries started by the maxilla. Materials and Methods: the surgeries were performed at Hospital S?o Lucas. Manual and three-dimensional tracings were made, respectively, in lateral cephalograms and CBCT with Dolphin Imaging Software by 2 independent evaluators, one of them was blinded to the proposed surgical movements for each patient. A custom cephalometric analysis was developed and applied to both forms of assessment (manual and three-dimensional). In the tracings, 9 pre and postoperative measures were evaluated. Four were vertical in relation to the PHF and were used to measure the maxillomandibular vertical changes, and five were in relation to the horizontal line N-perp, representing the anteroposterior maxillomandibular changes. Intraexaminer and interexaminer reliabilities were evaluated. The accuracy was measured by the RMSE. Precision was calculated from the comparison of standard deviations. Results: The three-dimensional assessment method showed better accuracy and precision when compared to the manual method. The mean scores of the differences between planned movements and performed movements in each method were lowerin three-dimensional assessment method group for five of the six variables (P <0.05). Conclusions: the planned movements are identified in the postoperative period. The three-dimensional assessment method is more precise and more accurate to evaluate and quantify these movements. Conclusions: the planned movements are identified in the postoperative period. The three-dimensional assessment method is more need and more accurate to evaluate and quantify These movements. It is Suggested que studies Evaluating results through manual assessment method overestimate the results. Perhaps the best way to Achieve this is through the three-dimensional assessment method. The knowledge and experience of the surgeon responsible for processing is fundamental in the treatment to be reproduced in patients in the trans-surgical, what was actually planned. / Objetivo: avaliar a acur?cia e a precis?o do m?todo de avalia??o manual dos resultados, realizado a partir de radiografias teleperfil em 20 pacientes padr?o facial classe II e III submetidos ? Cirurgia Ortogn?tica Bimaxilar, comparando-o com a avalia??o tridimensional realizada a partir de Tomografias Computadorizadas de face do tipo Cone-Beam (TCCB) nos per?odos pr? e p?s-operat?rio (6 meses), em cirurgias iniciadas pela maxila. Materiais e M?todos: As cirurgias foram realizadas no Hospital S?o Lucas da PUCRS. Tra?ados manuais e tridimensionais foram feitos, respectivamente, em telerradiografias de perfil e em Tomografias computadorizada cone-beam com o Dolphin Imaging Software, por 2 avaliadores independentes, sendo um deles cegado em rela??o aos movimentos cir?rgicos propostos para cada paciente. Foi desenvolvida uma an?lise cefalom?trica customizada e aplicada ?s duas formas de avalia??o (manual e tridimensional). Sobre os tra?ados, foram avaliadas 9 medidas pr? e p?s-operat?rias. Dessas medidas, quatro foram verticais em rela??o ao Plano horizontal de Frankfurt e serviram para mensura??o das mudan?as maxilomandibulares no sentido vertical, e cinco foram horizontais em rela??o ? Linha N-perp, representando as mudan?as maxilomandibulares no sentido ?ntero-posterior. Para avaliar a confiabilidade intra e inter-examinador metade dos tra?ados foi refeito ap?s 30 dias. A acur?cia foi medida atrav?s da raiz do erro quadr?tico da m?dia (RMSE). A precis?o foi calculada a partir da compara??o dos desvios-padr?o. Resultados: o m?todo tridimensional de avalia??o apresentou melhor acur?cia e precis?o quando comparado ao m?todo manual. As m?dias dos escores das diferen?as entre os movimentos planejados e os movimentos executados em cada um dos m?todos de avalia??o foram menores no grupo do m?todo de avalia??o tridimensional para todas as cinco vari?veis analisadas (P<0,05). Conclus?es: os movimentos previstos s?o identificados no per?odo p?s-operat?rio. O m?todo tridimensional ? mais preciso e mais acurado para avaliar e quantificar esses movimentos. O conhecimento e a experi?ncia do cirurgi?o respons?vel pelo tratamento representa parte fundamental no tratamento para que seja reproduzido no paciente no trans-cir?rgico, aquilo que realmente foi planejado.
223

Sinal do halo em tomografia computadorizada de t?rax : valor diagn?stico em pacientes imunocompetentes e imunocomprometidos

Alves, Giordano Rafael Tronco 13 August 2018 (has links)
Submitted by PPG Medicina e Ci?ncias da Sa?de (medicina-pg@pucrs.br) on 2018-09-03T12:29:41Z No. of bitstreams: 1 GIORDANO_RAFAEL_TRONCO_ALVES.pdf: 4296387 bytes, checksum: 0ebd26ada0ccec344a04ffbbd329dfae (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-09-03T14:24:25Z (GMT) No. of bitstreams: 1 GIORDANO_RAFAEL_TRONCO_ALVES.pdf: 4296387 bytes, checksum: 0ebd26ada0ccec344a04ffbbd329dfae (MD5) / Made available in DSpace on 2018-09-03T14:30:50Z (GMT). No. of bitstreams: 1 GIORDANO_RAFAEL_TRONCO_ALVES.pdf: 4296387 bytes, checksum: 0ebd26ada0ccec344a04ffbbd329dfae (MD5) Previous issue date: 2018-08-13 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction: The halo sign consists of an area of ground-glass opacity surrounding pulmonary lesions on chest computed tomography (CT) scans. Different diseases have already been described as causing this finding, though a larger and more objective analysis of this sign has not been conducted yet. Materials and methods: The authors compared CT images of immunocompetent and immunosuppressed patients in terms of halo sign features and seek to identify those of greatest diagnostic value. An observational study of exams performed between January of 2011 and May of 2015 was carried out. After initial database search with keywords, two thoracic radiologists reviewed the scans in order to determine the number of lesions, as well as their distribution, size, and contour, together with halo thickness and any other associated findings. The study obtained approval by the institutional ethics committee. The chi-squared test, Student t test and Mann-Whitney U test were adopted according to sample characteristics, with a bilateral level of significance of 0.05. Results: A total of 85 patients (46 male, 54%) were evaluated, with 53 (62%) immunocompetent and 32 (38%) immunosuppressed. The main diagnosis among immunocompetents was lung cancer (n=32, 64%), whereas aspergillosis was the main condition in immunosuppressed patients (n=25, 78%). Multiple and randomly distributed lesions were more frequent in the immunosuppressed group (p<0.001), with halo thickness also greater in this group (p<0.05). Conclusions: We concluded that the causes of the halo sign differ significantly according to immune status, and that halo thickness, the number and the distribution of lesions are the data with greatest diagnostic value. / Introdu??o: O sinal do halo consiste em uma ?rea de opacidade em vidro-fosco ao redor de les?es pulmonares em imagens de tomografia computadorizada (TC) de t?rax. Diferentes doen?as j? foram descritas como causadoras deste achado, por?m uma an?lise maior e mais objetiva deste sinal ainda n?o foi conduzida. Materiais e m?todos: Os autores compararam imagens tomogr?ficas de pacientes imunocompetentes e imunocomprometidos quanto a caracter?sticas do sinal do halo, a fim de identificar as de maior valor diagn?stico. Realizou-se um estudo observacional de exames realizados entre janeiro de 2011 e maio de 2015. Ap?s busca inicial em banco de dados com palavras-chave, dois radiologistas tor?cicos analisaram os exames para determinar o n?mero de les?es e sua distribui??o, tamanho e contorno, bem como a espessura do halo e outros achados associados. O estudo obteve aprova??o do comit? de ?tica institucional. Os testes de Qui-quadrado, t de Student e U de Mann-Whitney foram adotados de acordo com caracter?sticas amostrais, com um n?vel de signific?ncia de 0,05 bilateral. Resultados: Um total de 85 pacientes (46 homens, 54%), foram avaliados, sendo 53 (62%) imunocompetentes e 32 (38%) imunocomprometidos. O principal diagn?stico entre os imunocompetentes foi o de neoplasia pulmonar (n=32, 64%), enquanto a aspergilose foi a principal condi??o entre imunocomprometidos (n=25, 78%). Les?es m?ltiplas e de distribui??o rand?mica foram mais frequentes no grupo imunocomprometido (p<0,001), sendo a espessura do halo tamb?m maior neste grupo (p<0,05). Conclus?es: Conclui-se que as causas de sinal do halo diferem significativamente de acordo com o estado imunol?gico, sendo a espessura do halo, o n?mero e a distribui??o das les?es os dados de maior valor diagn?stico.
224

Desenvolvimento de um software para avaliação de qualidade de imagens tomográficas usando o Phantom Catphan500® / Development of a Software for Image Quality Assessment in Computed Tomography using the Catphan500® Phantom

Daniel Vicente Vieira 07 October 2016 (has links)
Desde a invenção da tomografia computadorizada (CT) nos anos 70, toda década trouxe novas tecnologias para esta modalidade. Com estes avanços, também surgiu a necessidade de novas e melhores técnicas de avaliação de desempenho e segurança dos equipamentos de CT. Hoje, o controle de qualidade de equipamentos de CT é, em grande parte, feito manualmente. Portanto, é lento e, em parte, subjetivo. Neste trabalho, um software foi escrito em MatLab® para processar imagens do phantom de CT Catphan500®, aperfeiçoando a rotina do programa de controle de qualidade de CT. Com pouca interferência do usuário, o software mede a espessura de corte, incremento entre cortes e tamanho de pixel, avalia a linearidade do número CT, estima a Função Transferência de Modulação (MTF), o ruído e o Espectro de Potência do Ruído (NPS). Para a validação do software, conjuntos de imagens do phantom foram obtidas em 10 equipamentos de CT diferentes, com 27 protocolos diferentes. Cada conjunto foi analisado pelo software, e os resultados obtidos foram comparados aos resultados previamente obtidos pela rotina normal do programa controle de qualidade. Para essa comparação, dois testes de hipótese foram empregados: o teste t de Student (para os valores de espessura de corte, incremento entre cortes, tamanho de pixel e os coeficientes da avaliação de linearidade do número CT, adotando um valor-p de 0,01) e o teste F de Fisher (para o ruído, valor-p de 0,05). As funções MTF e NPS atualmente não são medidas na rotina do controle de qualidade, portanto não há resultado prévio para fazer esta comparação. Ao invés disso, o NPS foi ajustado em função da MTF (através da relação teórica que há entre os dois) e a qualidade do ajuste foi avaliada pelo teste de qui-quadrado. Dos 101 valores de t e 25 valores de F calculados, 2 e 1 respectivamente estavam fora do intervalo de aceitação. Este resultado está de acordo com os valores-p escolhidos e, portanto, os resultados obtidos pelo software estão de acordo com os resultados da rotina de controle de qualidade convencional. Os ajustes de NPS e MTF obtiveram incertezas grandes nos parâmetros de ajuste (incertezas da mesma ordem de grandeza dos próprios parâmetros). Porém, a avaliação do qui-quadrado reduzido indica que os ajustes foram aceitáveis (com exceção de um, que mostrou uma anomalia no NPS medido e foi desconsiderado). Portanto, o NPS e MTF obtidos estão de acordo com a expectativa teórica. / Since the introduction of the CT scanner as a diagnostic imaging modality, the scientific community has seen new and more complex CT technologies. These improvements brought the need for new and improved techniques to evaluate the safety and performance of these scanners. Nowadays, the interpretation of images generated during the implementation of CT quality control procedures are done visually in much of the cases. Therefore, it is slow and partially subjective. In this work, a software was written in MatLab to process images of the Catphan500 CT phantom, in order to improve the CT quality control workflow and its accuracy. The software evaluate the slice thickness, slice increment, and pixel size, calculates the CT number linearity, and assesses the Modulation Transfer Function (MTF), the noise and the Noise Power Spectrum (NPS). Image sets of the phantom were obtained from 10 different scanners using 27 different protocols in order to validate the software. Comparative results correlating the software output and corresponding data previously obtained by the current quality control program routine were used to conduct this validation. For this comparison, two statistical tests were employed: the Students t-test (for slice thickness, slice increment, pixel size, and the coefficients of the CT number linearity evaluation, with a chosen p-value of 0.01) and the Fisher F-test (for the noise, with chosen p-value of 0.05).The functions MTF and NPS are not currently measured by the quality control routine, so there was no previous result for comparison. Instead, the NPS was fitted as a function of the MTF (using the theoretical relationship between both functions) and the quality of the fit was evaluated using the reduced chi-square. From 101 t values and 25 F values calculated, 2 and 1 were outside the acceptance interval, respectively. This result agrees with the chosen p-values, and therefore the software results are in good agreement with the traditional quality control routine results. The fits of NPS and MTF presented large uncertainties in the fitting parameters (uncertainties of the same order of magnitude as the parameters themselves). However, the reduced chi-square evaluation indicates a good fit (with the exception of one fit, which showed an anomaly on the measured NPS and was unconsidered). Therefore, the obtained MTF and NPS were in agreement with the theoretical expectations.
225

Efeitos da sitagliptina no tecido ósseo em ratos diabéticos e não diabéticos /

Bautista, Cristhian Reynaldo Gomez. January 2018 (has links)
Orientador: Ana Lia Anbinder / Banca: Luana Marotta Reis de Vasconcellos / Banca: Denise Pontes Raldi / Resumo: A diabetes mellitus, doença caracterizada pelo aumento da glicemia no sangue, é um dos mais importantes problemas de saúde pública do mundo, com incidência crescente, sobretudo em países em desenvolvimento. Novas terapias medicamentosas para controlar os níveis de glicose no sangue têm sido desenvolvidas, entre elas, os inibidores da enzima dipeptidil peptidase-4 (DPP-4) como a sitagliptina. Pesquisas atuais mostram que este medicamento, além do controle da glicemia, contribui na estimulação da formação e inibição da reabsorção óssea e possui ação anti-inflamatória. O objetivo deste trabalho foi avaliar os efeitos da sitagliptina no tecido ósseo em ratos diabéticos e não diabéticos. Foram utilizados 38 ratos machos, divididos em 4 grupos: Grupo diabético tratado com sitagliptina (GDS- 10 mg/Kg/dia); Grupo diabético (GD); Grupo normoglicêmico tratado sitagliptina (GNS-10 mg/Kg/dia); Grupo normoglicêmico (GN). Para indução da diabetes os animais receberam solução 10% de frutose na água de beber por 14 dias, após o quê receberam 40 mg/Kg de estreptozotocina via intraperitoneal. Quatro semanas depois, avaliou-se a glicemia e iniciou-se o tratamento com sitagliptina nos grupos GDS e GNS, que continuou por mais 4 semanas, quando ocorreu a eutanásia. A glicemia e a resistência à insulina (HOMA-IR) foram avaliadas também no dia da eutanásia. As tíbias foram removidas e avaliadas a porcentagem de volume ósseo (BV/TV), espessura trabecular (Tb.Th), número de trabéculas (Tb.N) e a separ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Diabetes mellitus, a disease characterized by increased blood glucose levels, is one of the most important public health problems in the world, with a growing incidence, especially in developing countries. New drug therapies to control blood glucose levels have been developed, including dipeptidyl peptidase-4 (DPP-4) inhibitors such as sitagliptin. Current research shows that this drug, in addition to glycemic control, contributes to stimulate the formation and inhibition of bone resorption and has an anti-inflammatory action. The aim of this study was to evaluate the effects of sitagliptin on bone tissue in diabetic and non-diabetic rats. Thirty-eight male rats were divided into four groups: Diabetic group treated with sitagliptin (GDS-10 mg / kg / day); Diabetic group (GD); normoglycemic group treated with sitagliptin (GNS-10 mg / kg / day); normoglycemic group (GN). For induction of diabetes the animals received 10% solution of fructose in the drinking water for 14 days, after which they received 40 mg / kg streptozotocin intraperitoneally. Four weeks later, glycemia was evaluated and sitagliptin treatment was started in the GDS and GNS groups, which continued for another 4 weeks, when euthanasia occurred. Blood glucose and insulin resistance (HOMA-IR) were also evaluated on the day of sacrifice. Bone volume (BV/TV), trabecular thickness (Tb.Th), number of trabeculae (Tb.N) and trabeculae separation (Tb.Sp) of the tibial metaphysis were evaluated by computerized microtomog... (Complete abstract click electronic access below) / Mestre
226

Proposta de um sistema de banco de dados para tomografia por ressonância magnética nuclear / Proposal of a database system for magnetic resonance imaging

Freire, Henrique Jota de Paula 05 December 1997 (has links)
Este trabalho é uma proposta e uma implementação de um sistema de banco de dados para ser utilizado no armazenamento e gerenciamento dos dados resultantes da operação de tomógrafos de ressonância magnética nuclear. O objetivo é obter tecnologia na área de sistemas de arquivamento e comunicação de imagens médicas. O trabalho insere-se em um esforço maior do grupo de ressonância do IFSC/USP-São Carlos na pesquisa e desenvolvimento de tecnologias na área de imagens por ressônancia magnética. A motivação para a utilização de sistemas digitais de bancos de dados para o armazenamento e gerenciamento de imagens médicas é o crescente aumento do volume gerado deste tipo de imagem nas instalações médicas. Quando comparado com o sistema de armazenamento tradicional, baseado em filmes, os sistemas digitais prometem ser mais seguros, eficientes e eficazes, além de proporcionar novas possibilidades na área de diagnóstico médico. Os principais resultados do trabalho são um modelo de dados conceitual elaborado com o modelo Entidade-relacionamento Estendido; um modelo de implementação relacional; e um sistema de banco de dados desenvolvido para uma plataforma computacional baseada em microcomputador e sistema operacional da família Windows. A metodologia utilizada no desenvolvimento do trabalho é baseada em conceitos básicos da disciplina de engenharia de programação. O sistema de banco de dados foi desenvolvido utilizando um sistema de gerenciamento de banco de dados comercial, o Microsoft Acess Versão 2.0. O trabalho também apresenta o padrão industrial DICOM 3,0 e destaca as partes que são específicas para a modalidade de imagens médicas por ressonância magnética e que foram implementadas neste trabalho. / This work is a proposal and an implementation of a database system for archiving and management of data related to the operation of magnetic resonance imaging systems. The objective is to acquire technology in the area of medical image archiving and communication systems. This work is part of a broader effort of the IFSC/USP-São Carlos magnetic resonance group in the research and development of technologies in the area of magnetic resonance imaging. The reason for using digital database systems to archive and manage medical images is the growing volume of this kind of images in medical institutions. When compared to the traditional film based archiving systems, digital systems claim to be more secure, efficient and effective, besides giving place to new possibilities in medical diagnoses. The main results of this work are: a conceptual data model built with the Enhanced Entity-relationship model; a relational implementation model; and a database system to run in a PC-Windows computational platform and operational system. The methodology used throughout the development of this work is based on some basic concepts of the software engineering discipline. The database system was developed using a commercial database management system, the Microsoft® Access® Version 2.0. This work also presents the industrial standard DICOM 3.0 and highlights those parts that are specific for the magnetic resonance imaging modality and were implemented in this work.
227

Complementação tomográfica da classificação de Schatzker para as fraturas do planalto tibial / Tomographic complementation of the schatzker classification for tibial plateau fractures

Castiglia, Marcello Teixeira 28 July 2017 (has links)
As fraturas do planalto tibial são lesões com um espectro muito variado de manifestação clínica. Diversos sistemas de classificação foram desenvolvidos para facilitar a compreensão e a tomada de decisões no tratamento dessas lesões. O presente estudo teve como objetivo primário avaliar o impacto da tomografia computadorizada na concordância inter e intraobservador da classificação de Schatzker. Além disso, procurou-se avaliar o impacto da tomografia computadorizada na tomada de decisões a respeito da via de acesso cirúrgico ao planalto tibial, utilizando para esta análise a classificação de Schatzker modificada por Kfuri. Um banco de dados com imagens de 70 pacientes, incluindo radiografias, tomografia computadorizada e reconstruções tridimensionais computadorizadas foi oferecido a um grupo de 10 observadores para análise. Como resultados, observou-se que a classificação de Schatzker apresentou coeficiente de concordância moderado, quando baseado no uso de radiografias (k=0,58), e substancial quando esta análise foi complementada por tomografia (k=0,62/0,64). A nova classificação de Schatzker modificada por Kfuri obteve nível moderado de concordância interobservador (k=0,53) e substancial intraobservador (k=0,63). A tomografia computadorizada, elemento básico da nova classificação, influenciou decisivamente os cirurgiões a mudarem a opção pela via de acesso cirúrgico, especialmente em fraturas com orientação no plano coronal. Como conclusão, verificou-se que a classificação de Schatzker modificada por Kfuri demonstrou substancial índice de concordância intraobservador e moderado índice de concordância intraobservador, e devem ser úteis para a prática clínica. / Tibial plateau fractures are lesions with a varied spectrum of clinical presentation. Several classification systems have been developed to facilitate the understanding and decision making in the treatment of these injuries. The present study aimed to evaluate the impact of computerized tomography on the inter and intraobserver correlation of the Schatzker classification. In addition, we sought to evaluate the impact of the computed tomography in the decision making regarding the surgical approaches to the tibial plateau, using the Schatzker classification modified by Kfuri for this analysis. A database of 70 patient images, including radiographs, computerized tomography, and computerized three-dimensional reconstructions were offered to a group of 10 observers for analysis. As a result we observed that the Schatzker classification presents a moderate agreement when based on radiographs (k=0,58) and substantial when this analysis is complemented by tomography (k=0,62/0,64). The new Schatzker classification modified by Kfuri has a moderate level of interobserver agreement (k=0,53) and substantial intraobserver agreement (k=0,63). Computerized tomography, a basic element of the new classification, decisively influenced surgeons to change the option for surgical access, especially in fractures with orientation in the coronal plane. In conclusion, the Schatzker classification modified by Kfuri have a substantial intraobserver and moderate interobserver correlation, and should be useful for clinical practice.
228

Quantificação automática da gordura epicárdica em imagens de tomografia computorizada

Figueiredo, Bruno Manuel Ferreira de January 2009 (has links)
Tese de Mestrado. Engenharia Biomédica. Faculdade de Engenharia. Universidade do Porto, Centro Hospitalar de Vila Nova de Gaia. 2009
229

Medical x-ray images of the human thorax : segmentation, decomposition and reconstruction

Vinhais, Carlos Alberto Afonso January 2007 (has links)
Tese de doutoramento. Engenharia Electrotécnica e de Computadores. Faculdade de Engenharia. Universidade do Porto. 2007
230

Análise comparativa entre arranjos de tomografia elétrica e sua aplicação na pesquisa de ocorrência de cobre disseminado /

Paes, Renata Augusta Sampaio. January 2019 (has links)
Orientador: Cesar Augusto Moreira / Resumo: A área de estudo está localizada próxima a Caçapava do Sul no estado do Rio Grande do Sul, ocorrência conhecida como Colônia Santa Barbara. A ocorrência está situada na Bacia do Camaquã, alocada estruturalmente em um bloco alto, na interseção de duas falhas com direções NE-SW e NW-SE, com litologias aflorantes pertencentes ao Complexo Metamórfico Bossoroca e Formação Hilário do Grupo Bom Jardim. Descrita entre 1960 e 1970, a pesquisa foi suspensa após análise geoquímica apontar teores de cobre insatisfatórios, não ultrapassando a 1%, sem interesse econômico. Atualmente com uso de aparelhos multi-cabos de aquisição automática é possível a realização de ensaios geoelétricos de diferentes arranjos em menor tempo e maior praticidade, o que impulsionou o desenvolvimento deste trabalho. Essa dissertação apresenta a análise comparativa dos dados de tomografia elétrica em arranjo Schlumberger, Wenner e Dipolo-Dipolo, para averiguar o resultado que descreva a morfologia mais realista esperada do jazimento, baseado no modelo magmático hidrotermal com forte controle estrutural. A análise comparativa entre os arranjos de tomografia elétrica proposta neste trabalho revelou a conformação de um corpo cônico de alta cargabilidade (2,7 mV/V) que engloba o núcleo vertical de alta resistividade (438 Ω.m), além de uma zona anelar de alta cargabilidade possivelmente correlacionada ao sistema de falhas que estruturam o alto estrutural (tufo vulcânico). A estrutura cônica observada é compatível com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study area is located near to Caçapava do Sul, at Rio Grande do Sul State, an occurrence known as Colônia Santa Barbara. The occurrence is in the Camaquã Sedimentary Basin, structurally allocated in a high block, at the two faults intersection with NE-SW and NW-SE directions, with outcropping lithologies belonging to Bossoroca Metamorphic Complex, and Hilario Formation. Described between 1960 and 1970, the research was suspended after geochemical analysis pointed to unsatisfactory copper levels, not exceeded 1%, without economic interest. Nowadays, with the use of automatic and multicable devices, like Terrameter Ls, it is possible to perform different arrangements geometric tests in a shorter time and greater practicality, fact that support this work development. This dissertation presents the electrical tomography arrays comparative analysis to Schlumberger, Wenner, and Dipolo-Diplo, to verify the result that describes the most realistic expected deposit morphology, based in a hydrothermal magmatic metallogenetic deposit with high structural control. The comparative analysis revealed a conical body with high chargeability conformation (2,7 mV/V) that encompasses the high resistivity vertical core (438 Ω/m ), as well as an annular portion with high chargeability possibly correlated to the fault zone that structures the central and high block (volcanic tuff). The conical structure observed is compatible with the dike, vertical and cylindrical morphology described for hydr... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0597 seconds