• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Projeto e avaliação de um canal de medição de bioimpedâncias

Porto, Rodrigo Wolff January 2009 (has links)
Esta dissertação trata do projeto e avaliação de um canal de medição de bioimpedâncias multifrequencial cujo objetivo é a medida em módulo e fase de impedâncias até 1 k com desempenho reportado nas freqüências 100 kHz, 300 kHz e 1 MHz. Um modelo teórico foi desenvolvido para cada etapa do canal de medição incluindo as não idealidades dos componentes utilizados na implementação prática. A análise da sensibilidade à variação de parâmetros e da propagação de incertezas nas etapas do sistema foi realizada juntamente com a avaliação experimental da exatidão e precisão do protótipo desenvolvido. O circuito proposto apresenta incerteza experimental 0,008% nas medidas de amplitude e 0,05% nas medidas de fase. / This dissertation deals with the project and evaluation of a multifrequency bioimpedance measurement channel whose objective is to obtain the measure in module and phase of load impedances up to 1 k with performance reported in 100 kHz, 300 kHz and 1 MHz. A theoretical model was developed for each stage of the measurement channel having included non-idealities of the components used in the practical implementation. The sensitivity analysis with respect to parameter variation and uncertainty analysis in the stages of the system was carried through together with the experimental evaluation of the accuracy and precision of the developed prototype. The considered circuit presents experimental uncertainty of 0.008% in the measures of amplitude and 0.05% in the measures of phase.
252

Desenvolvimento de um novo método para avaliação da qualidade da imagem em tomografia computadorizada de feixe cônico

Oliveira, Marcos Vinícius Linhares de January 2016 (has links)
Submitted by Kleber Ferreira (kcf@ufba.br) on 2017-03-09T22:08:37Z No. of bitstreams: 1 MARCUS VINÍCIUS LINHARES DE OLIVEIRA.pdf: 4896468 bytes, checksum: 2d25d39f03d0b3127ffecebbf3142711 (MD5) / Made available in DSpace on 2017-03-09T22:08:37Z (GMT). No. of bitstreams: 1 MARCUS VINÍCIUS LINHARES DE OLIVEIRA.pdf: 4896468 bytes, checksum: 2d25d39f03d0b3127ffecebbf3142711 (MD5) / Os exames de tomografia computadorizada por feixe de cone (CBCT) têm crescido em grande escala nos últimos anos. O estabelecimento de testes de garantia de qualidade é importante para garantir a manutenção da informação de diagnóstico utilizando protocolos otimizados. O uso de fantomas é essencial para fazer medições de parâmetros de qualidade de imagem. Além disso, sugere-se uma avaliação automática da imagem para evitar discordâncias inter e intraobservador. O objetivo deste trabalho foi desenvolver um novo método para avaliação dos parâmetros indicadores da qualidade da imagem de tomografia computadorizada de feixe cônico (TCFC) dental. Materiais e Métodos: Um fantoma composto por uma estrutura cilíndrica de polimetilmetacrilato (PMMA), contendo grupos de materiais de diferentes densidades que representam atenuação de várias estruturas anatômicas foi modificado e implementado para obtenção das imagens. As imagens do fantoma foram obtidas com diferentes protocolos de exposição em três unidades de TCFC: NewTom™ 5G (QR srl, Verona, Italy), Cranex® 3D (Soredex Oy, Tuusula, Finland) e Scanora 3D (Soredex Oy, Tuusula, Finland). Uma macro, designada CBCT_QA, foi desenvolvida, usando-se o software livre ImageJ (National Institutes of Health, USA), para avaliar automaticamente os parâmetros indicadores da qualidade de imagem de forma objetiva. Um sistema de gerenciamento foi desenvolvido para acompanhamento das avaliações. Resultados: A combinação do fantoma e da macro (CBCT_QA) permitiu a avaliação de oito parâmetros da qualidade de imagem: uniformidade, razão sinal-ruído (RSR), ruído, razão contraste-ruído (RCR), resolução espacial, índice de artefato, acurácia geométrica e baixo contraste. Os valores dos indicadores da qualidade da imagem variaram de acordo com a unidade de TCFC. O fantoma pode ser aplicado para avaliação da qualidade da imagem em equipamentos com FOV pequeno, médio e grande. O CBCT_QA permite que os resultados obtidos sejam exportados para uma planilha do Microsoft Excel, impresso em .pdf ou armazenados para acompanhamento ao longo do tempo. No relatório final, os valores do produto dose área (DAP) também são apresentados. Conclusão: A metodologia desenvolvida neste estudo demonstrou ser de rápida aplicação, de baixo custo e um método reprodutível para avaliação de parâmetros de qualidade de imagem em TCFC. / Cone beam computed tomography (CBCT) examinations have grown on a large scale in the past years. The establishment of quality assurance testing is important to ensure diagnostic information maintenance using optimized protocols. The use of phantoms is essential to make measurements of image quality parameters. Furthermore, an automatic image evaluation is suggested in order to avoid inter- and intra-observer disagreement. The aim of this study was to develop a system (phantomsoftware) to evaluate the image quality in dental and maxillo-facial cone beam computed tomography (CBCT). Materials and Methods: A polymethylmethacrylate (PMMA) phantom with cylindrical structure, containing groups of different densities materials, representing attenuation of various anatomical structures was modified and implemented for image acquisition. The phantom´s images were obtained according different exposure protocols in three units of CBCT: NewTom 5G™ (QR srl, Verona, Italy), 3D Cranex® (Soredex Oy, Tuusula, Finland) and 3D Scanora (Soredex Oy, Tuusula, Finland ). A macro, called CBCT_QA, in order to evaluate the image quality parameters automatically and objectively, was developed using a free software, ImageJ (National Institutes of Health, USA). A management system was developed to record the evaluation´s results. Results: Phantom and macro (CBCT_QA) allowed the evaluation of eight image quality parameters: uniformity, signal to noise ratio (SNR), noise, contrast-to-noise ratio (CNR) spatial resolution, artifact index, geometric accuracy and low contrast. The values of image quality indicators ranged according to CBCT units. Phantom allowed the evaluation of image quality in devices with small, medium and large FOV. The results obtained can be exported to a spreadsheet from Microsoft Excel, printed in .pdf or stored for tracking over time. Also, in the final report, the values from dose area product (DAP) are presented. Conclusion: The new method developed in this study presented fast application, low cost and a reproducible method for evaluating image quality parameters in CBCT.
253

Acurácia da imagem de diferentes tomográfos de feixe cônico na avaliação da cobertura óssea em dentes anteriores

Dantas, Luciana Loyola January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-03-13T13:00:53Z No. of bitstreams: 1 Dissertação_Final.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-03-23T13:22:47Z (GMT) No. of bitstreams: 1 Dissertação_Final.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / Made available in DSpace on 2017-03-23T13:22:47Z (GMT). No. of bitstreams: 1 Dissertação_Final.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / CNPQ / O presente estudo teve como objetivo determinar a acurácia diagnóstica da imagem obtida a partir de diferentes tomógrafos de feixe cônico na avaliação da presença ou ausência de cobertura óssea em dentes anteriores. Foram adquiridas imagens de TCFC da região de maxila e mandíbula de um crânio seco em seis diferentes tomógrafos: Accuitomo (J. Morita, Kyoto, Japão); CS 9000 3D (Carestream Dental, Trophy, Marne La Vallée, França); CS 9300 (Carestream Dental, Trophy, Marne La Vallée, França); Eagle 3D (Dabi Atlante, Oklahoma, EUA); i-CAT Classic (Imaging Sciences International, Hatfield, Pensilvânia, EUA) e Orthophos XG 3D (Sirona Dental System, Charlote, EUA). Dois radiologistas avaliaram as imagens e um ortodontista avaliou o crânio seco. Os resultados demonstraram alta acurácia diagnóstica na avaliação da cobertura óssea nos tomógrafos estudados, com uma superioridade do CS 9300, que além de alta acurácia, apresentou alta sensibilidade e especificidade com um menor tempo de escaneamento e menor exposição do paciente à radiação ionizante. / This study was carried out to determine the diagnostic accuracy of image obtained from different cone beam tomography in the evaluation of the presence or absence of bone coverage in anterior teeth. CBCT images were acquired from the maxillary and jaw region of a dry skull in six different devices - Accuitomo (J. Morita, Kyoto, Japan); CS 9000 3D (Carestream Dental, Trophy, Marne La Vallee, France); CS 9300 (Carestream Dental, Trophy, Marne La Vallee, France); Eagle 3D (Dabi Atlante, Oklahoma, USA); i-CAT Classic (Imaging Sciences International, Hatfield, Pensilvânia, EUA) and Orthophos XG 3D (Sirona Dental System, Charlotte, USA). Two radiologists evaluated the images and an orthodontist evaluated the dry skull. The results showed high diagnostic accuracy in the evaluation of bone coverage in CBCT scanners, with a superiority of the CS 9300, which in addition to high accuracy, showed high sensitivity and specificity with less time scanning and less patient exposure to ionizing radiation.
254

Acurácia da imagem tomográfica de feixe cônico na avaliação da ausência de cobertura óssea em dentes anteriores

Ferreira, Paula Paes January 2014 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-03-23T13:03:50Z No. of bitstreams: 1 pdf final.pdf: 3790512 bytes, checksum: 9e36ae4b4df28d2680d296d98fff6de4 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-03-23T13:07:45Z (GMT) No. of bitstreams: 1 pdf final.pdf: 3790512 bytes, checksum: 9e36ae4b4df28d2680d296d98fff6de4 (MD5) / Made available in DSpace on 2017-03-23T13:07:45Z (GMT). No. of bitstreams: 1 pdf final.pdf: 3790512 bytes, checksum: 9e36ae4b4df28d2680d296d98fff6de4 (MD5) / FAPESB / O diagnóstico da ausência de cobertura óssea (CO) na região vestibular dos dentes anteriores é fundamental para o planejamento e tratamento em diversas áreas da Odontologia. Porém, a avaliação de diminutos defeitos ósseos representa um desafio à ciência, que através de inúmeros exames por imagem busca à acurada avaliação frente a estas situações. Com o advento e consolidação da Tomografia Computadorizada de Feixe Cônico (TCFC) como excelente método para quantificar osso com a possibilidade de doses de radiação reduzidas, este trabalho tem como objetivo avaliar o diagnóstico da ausência de CO, em dentes anteriores, através de imagens por TCFC. Para tanto, cinco crânios secos foram selecionados e os defeitos ósseos identificados através da análise visual direta dos dentes anteriores. TCFC parciais da maxila e da mandíbula de cada crânio foram realizadas e as imagens analisadas por dois examinadores, que identificaram a presença ou não de cobertura óssea em cada região. Nas reconstruções axiais, 93,65% das ausências de cobertura óssea foram diagnosticadas pelo avaliador A e 92,06% pelo avaliador B, já nas imagens sagitais, 65,01% desses defeitos foram visualizados pelo avaliador A e 82,54% pelo avaliador B, sendo que ao juntar o diagnóstico das duas reconstruções, 95,24% de todos os defeitos ósseos presentes nos crânios foram diagnosticados corretamente por ambos avaliadores. Sendo assim, a TCFC apresentou uma acurácia de 98,33% e 88,33%, uma sensibilidade de 100% e 95,65% e uma especificidade de 97,3% e 83,78% para os avaliadores A e B respectivamente, demonstrando ser um exame excelente e, portanto, válido para o diagnóstico da ausência de CO na cortical vestibular dos dentes anteriores. / The diagnosis of the absence of buccal bone coverage on anterior teeth is important for the planning and treatment in many areas of Dentistry. However, evaluation of small bone defects represents a challenge to science, which through many images, search an accuracy evaluation for these situations. With the advent and consolidation of the Cone Beam Computed Tomography (CBCT) as an excellent method to evaluate the bone quantity, with low radiation dose, this study aims to evaluate the diagnosis of absence of bone coverage in anterior teeth through CBCT images. Five dry skulls were clinically evaluated to detect bone defects in the anterior teeth. CBCT images of the maxilla and mandible were assessed by two observers, which identified the presence or absence of bone coverage in each region. The axial reconstruction showed 93.65% of regions with a lack of bone coverage by the observer A and 92.06% by the observer B, while on the sagittal reconstructions 65.01% of these defects were detect by the observer A, and 82.54% by the observer B. When analyzed both reconstructions, 95.24% of bone defects were diagnosed by both observers. Thus, the CBCT showed for A and B observers an accuracy of 98.33% and 88.33%, sensitivity of 100% and 95.65% and specificity of 97.3% and 83.78%, respectively, proving to be an excellent imaging modality for the diagnosis of absence of buccal bone coverage in anterior teeth.
255

Avaliação dimensional e do coeficiente de atenuação de tumores odontogênicos benignos por tomografia computadorizada.

Queiroz, Isaac Vieira January 2015 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-04-03T15:13:30Z No. of bitstreams: 1 Tese - Isaac.pdf: 1751790 bytes, checksum: 99280033f14e1c1228ca4a4450ada90f (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-06-29T14:30:51Z (GMT) No. of bitstreams: 1 Tese - Isaac.pdf: 1751790 bytes, checksum: 99280033f14e1c1228ca4a4450ada90f (MD5) / Made available in DSpace on 2017-06-29T14:30:51Z (GMT). No. of bitstreams: 1 Tese - Isaac.pdf: 1751790 bytes, checksum: 99280033f14e1c1228ca4a4450ada90f (MD5) / CAPES / O estudo visou a avaliar as características dimensionais e do coeficiente de atenuação (CoA) em Ameloblastomas, Tumor Odontogênico Ceratocístico (TOC) e Mixoma Odontogênico (MO). Foram selecionadas regiões de interesse (ROI) de imagens axiais por Tomografia computadorizada (TC) de feixe em leque de indivíduos portadores de Ameloblastomas, TOC e MO; representando a maior área de cada corte sem incluir tecido ósseo e/ou dentário. Avaliou-se o CoA (UHROI), a heterogeneidade (HTGROI) e a presença de áreas de alta densidade (AAD) intralesionais; além das medidas lineares no sentido mésio-distal, vestíbulo-lingual e súpero-inferior. As aferições foram realizadas por profissional previamente calibrado em ambiente de luz controlada, em monitor de alta resolução utilizando o software Osirix. A amostra foi composta por 43 lesões, sendo 60,5% do gênero feminino, 95,3% acometeram a mandíbula e 72,1% na região posterior. A média do CoA, em ordem decrescente em cada grupo de lesão foi: o MO (41,14UH+/-13,67UH), Ameloblastoma (36,52UH +/- 12,32UH) e TOC (31,03UH+/-7,64UH). Os valores referentes à HTGROI dos tumores são representados na seguinte ordem: TOC (110,87+/-71,27), AM (99,98+/-60,78), MO (84,86+/-30,23) e AU (82,42+/-40,08). Com relação às AAD também foi o MO que apresentou a maior prevalência 1,5% dos cortes, seguido pelo AM (1%), TOC (0,7%) e o AU não apresentou nenhuma. Com base nos resultados encontrados pode-se concluir que o MO foi o tumor que apresentou a maior densidade e maior prevalência de áreas de alta densidade. As regiões inferiores dos tumores concentraram os maiores valores de CoA e as regiões superiores mostraram-se as mais heterogêneas. O TOC foi a lesão mais heterogênea. / This study aimed to evaluate the dimensional characteristics and the Coefficient of Attenuation (CoA) in Ameloblastomas, Keratocystic Odontogenic Tumors (KOT) and Odontogenic Myxoma (OM). Regions of interest (ROI) were selected from axial images by Computed Tomography (CT) in a range of individuals with ameloblastomas, KOT and OM; it represents the largest area of each slice not including bone and/or dental tissues. It was evaluated the CoA (UHROI), heterogeneity (HTGROI) and the presence of intra-lesional high-density areas (HDA); additionally, we performed linear measurements in mesiodistal, buccolingual and superoinferior directions. The measurements were performed by professional previously calibrated under a light-controlled room, making use of a high-resolution display and OsiriX software. The sample consisted of 43 lesions, 60.5% female, 95.3% occurred in the mandible and 72.1% in the posterior region. The average CoA in descending order in each lesion group was: OM (41.14UH +/- 13.67UH), Ameloblastoma (36.52UH +/- 12.32UH) and KOT (31.03UH +/- 7.64UH). The amounts related to HTGROI tumors are represented in the following order: KOT (110.87 +/- 71.27), AM (99.98 +/- 60.78), OM (84.86 +/- 30.23) and UA (82.42 +/- 40.08). Regarding the HDA, OM also presented the highest prevalence in 1.5% of the cuts, followed by AM (1%), KOT (0.7%) and the AU did not present HDA. Based on these results, it was concluded that OM was the tumor presenting the highest density and a higher prevalence of HDA. The lower regions of tumors concentrated the highest CoA and the upper regions were the most heterogeneous ones. KOT was the most heterogeneous lesion.
256

Avaliação do coeficiente de atenuação e volume de lesões uniloculares benignas dos maxilares por tomografia computadorizada multislice.

Carneiro Junior, Braulio January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-04-04T13:34:45Z No. of bitstreams: 1 TESE COMPLETA.pdf: 6740473 bytes, checksum: e46e487e77f50e424239dfad9be11c29 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-06T13:01:04Z (GMT) No. of bitstreams: 1 TESE COMPLETA.pdf: 6740473 bytes, checksum: e46e487e77f50e424239dfad9be11c29 (MD5) / Made available in DSpace on 2017-07-06T13:01:04Z (GMT). No. of bitstreams: 1 TESE COMPLETA.pdf: 6740473 bytes, checksum: e46e487e77f50e424239dfad9be11c29 (MD5) / As lesões benignas presentes nos maxilares apresentam-se muito semelhantes nos exames de imagem bidimensionais, limitado assim, em muitos casos, o diagnóstico clínico - radiográfico. A tomografia computadorizada multislice pode apresentar-se como uma ferramenta útil no diagnóstico e avaliação destas lesões, uma vez que permite a avaliação e obtenção do coeficiente de atenuação, que representa a densidade dos tecidos. O presente estudo avaliou o padrão dos coeficientes de atenuação e volume de lesões uniloculares, através de medidas de imagens por tomografia computadorizada. Foram avaliadas 61 imagens de lesões diagnosticadas histopatologicamente e agrupadas em: Cisto Ósseo Traumático (n= 4), Cisto Odontogênico Glandular (n= 2), Cisto Radicular (n= 16), Cisto Dentígero (n=15), Tumor Odontogênico Queratocístico (n=15) e Ameloblastoma (n=9). Os Ameloblastomas foram divididos nos subtipos: Ameloblastoma Sólido (n=5) e Ameloblastoma Unicístico (n= 4) . Os coeficientes de atenuação e as medidas volumétricas das lesões foram obtidas através da utilização do programa Osirix, a partir da delimitação da lesão pela demarcação da região de interesse em cortes axiais. Para análise estatística foram usados testes não paramétricos Kruskal-Wallis, Dun e Mann-Whitney. Foram calculadas as médias e medianas do coeficiente de atenuação e volume da lesão. As médias e medianas do coeficiente de atenuação foram respectivamente: 34,75 ±10,51 e 35,94 para o Cisto Ósseo Traumático, 33,26 ± 2,29 e 33,26 para o Cisto Odontogênico Glandular, 44,47 ± 12,96 e 40,79 para o Cisto Radicular, 38,21±17,59 e 35,49 para o Cisto Dentígero, 36,73 ± 12,49 e 33,16 paro o Tumor Odontogênico Queratocístico e 37,83 ± 12,72 e 34,98 para o Ameloblastoma. Entre os subtipos do Ameloblastoma a diferença entre os coeficientes de atenuação foi significante sendo 33,09 ±8,25 e 32,76 no Ameloblastoma Unicístico e para o Ameloblastoma Sólido = 41,62 ±15,23 e 40,72. Os Cisto Radicular e o Ameloblastoma Sólido foram as lesões que apresentaram maior densidade, sendo também o Ameloblastoma Sólido a lesão que apresentou maior heterogeneidade. Em relação as medidas volumétricas a diferença entre a maxila e mandíbula foi estatisticamente significante (p=0,01) demonstrando maior volume das lesões na maxila. As lesões que apresentavam maiores volumes foram o Cisto Odontogênico Glandular e Ameloblastoma. Não foram observados resultados de significância estatística na relação do volume com idade e gênero. No caso dos Cistos Dentígeros e Ameloblastomas pode-se observar que nas lesões com maior volume os valores de Unidades Hounsfield foram menores. Contudo, não se observou diferenças significativas entre os valores do coeficiente de atenuação e volume entre as lesões estudadas. / Benign lesions of the jaws produce very similar two-dimensional images, a fact limiting in many cases the clinical and radiographic diagnosis. Multislice computed tomography is a useful tool for the diagnosis and evaluation of these lesions since it permits to obtain an attenuation coefficient that represents the density of tissues. This study evaluated the attenuation coefficients and volume of unilocular lesions measured on computed tomography images. Sixty-one images of the following histopathologically diagnosed lesions were analyzed: traumatic bone cyst (n=4), glandular odontogenic cyst (n=2), radicular cyst (n=16), dentigerous cyst (n=15), keratocystic odontogenic tumor (n=15), and ameloblastoma (n=9). The ameloblastomas were divided into subtypes: solid (n=5) and unicystic ameloblastoma (n=4). The attenuation coefficients and volume measurements of the lesions were obtained with the Osirix program by delimiting the region of interest in axial sections. The nonparametric Kruskal-Wallis, Dunn and Mann-Whitney tests were used for statistical analysis. Means and medians of the attenuation coefficients and lesion volume were calculated. The mean and median attenuation coefficients were, respectively, 34.75 ± 10.51 and 35.94 for traumatic bone cysts, 33.26 ± 2.29 and 33.26 for glandular odontogenic cysts, 44.47 ± 12.96 and 40.79 for radicular cysts, 38.21±17.59 and 35.49 for dentigerous cysts, 36.73 ± 12.49 and 33.16 for keratocystic odontogenic tumors, and 37.83 ± 12.72 and 34.98 for ameloblastomas. The difference in the attenuation coefficient between ameloblastoma subtypes was significant (unicystic: 33.09 ± 8.25 and 32.76; solid: 41.62 ± 15.23 and 40.72). Radicular cysts and solid ameloblastomas exhibited the highest density and the latter were also more heterogenous. The difference in the volume measurements between the maxilla and mandible was statistically significant (p=0.01), with more voluminous lesions occurring in the maxilla. Glandular odontogenic cysts and ameloblastomas exhibited the highest volumes. No significant differences in volume were observed according to age or gender. In the case of dentigerous cysts and ameloblastomas, more voluminous lesions had less Hounsfield units. However, no significant differences were observed between the values of attenuation coefficient and volume between the studied lesions.
257

Avaliação da acurácia de reconstruções panorâmicas geradas a partir de tomografia computadorizada: Estudo experimental in vitro com mandíbulas secas humanas.

Bomfim, Rodrigo Tavares January 2012 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-04-04T14:44:28Z No. of bitstreams: 1 Tese_ODONTO_Rodrigo Tavares Bomfim.pdf: 1531026 bytes, checksum: 350215cb102c45044fa277e6d178354a (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-06T13:14:54Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Rodrigo Tavares Bomfim.pdf: 1531026 bytes, checksum: 350215cb102c45044fa277e6d178354a (MD5) / Made available in DSpace on 2017-07-06T13:14:54Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Rodrigo Tavares Bomfim.pdf: 1531026 bytes, checksum: 350215cb102c45044fa277e6d178354a (MD5) / Os exames de tomografia computadorizada (TC) permitem a observação do segmento anatômico de interesse sob diferentes reconstruções, contribuindo para o diagnóstico e planejamento terapêutico. Na odontologia a reconstrução panorâmica dos maxilares é comumente utilizada, por permitir uma visualização longitudinal das arcadas dentárias, já que esta imagem se aproxima daquela da radiografia panorâmica, bastante familiar ao cirurgiãodentista. Para estas reconstruções, diversas empresas têm lançado no mercado diferentes softwares, que passaram a ser avidamente consumidos pelos profissionais. Tais softwares, no entanto, carecem de estudos científicos que comprovem a fidelidade das imagens geradas. O objetivo deste trabalho é avaliar a acurácia de reconstruções panorâmicas de mandíbulas secas humanas, produzidas pelos softwares DentalSlice® (BioParts – Prototipagem Biomédica, Brasília – DF, Brasil) e Osirix® (Pixmeo SARL, Genebra, Suíça). Para isto, foram confeccionados defeitos ósseos padronizados na região anterior e posterior de dez mandíbulas secas, que em seguida foram submetidas a exames de TC médica e de TC de feixe cônico. Os arquivos dos exames com voxels de diferentes espessuras, salvos no formato DICOM (Digital Imaging and Communications in Medicine) em mídia eletrônica, foram processados nos referidos programas, para obtenção das reconstruções panorâmicas das mandíbulas. Foram realizadas, então, medidas lineares verticais e horizontais nos defeitos ósseos das mandíbulas secas com um paquímetro digital, e correspondentemente nas reconstruções panorâmicas virtuais das mandíbulas, utilizando-se as réguas eletrônicas de cada software. As medidas foram realizadas por dois examinadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Conclui-se que as distâncias do software Osirix® apresentaram menor erro, em comparação com o DentalSlice®; que as medidas das distâncias na região posterior da mandíbula apresentam menor erro que as da região parassinfisária e que as distâncias verticais foram igualmente acuradas.
258

Fidelidade de modelos virtuais tridimensionais: avaliação por meio de engenharia reversa.

Queiroz, Christiano Sampaio January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2018-02-05T14:49:03Z No. of bitstreams: 1 Tese_ODONTO_ Christiano Sampaio Queiroz.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2018-02-16T16:40:14Z (GMT) No. of bitstreams: 1 Tese_ODONTO_ Christiano Sampaio Queiroz.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / Made available in DSpace on 2018-02-16T16:40:14Z (GMT). No. of bitstreams: 1 Tese_ODONTO_ Christiano Sampaio Queiroz.pdf: 1716780 bytes, checksum: c45cd043e723d001e983684db94f9adb (MD5) / A engenharia reversa refere-se a tecnologias capazes de capturar modelos físicos e representá-los com a linguagem da computação como modelos virtuais. Estes modelos virtuais podem ser utilizados com finalidades das mais diversas, sendo, na área da saúde, importantes no diagnóstico e planejamento cirúrgico. Para isto, quanto mais fiéis ao modelo físico, maior a segurança nestes procedimentos. O presente trabalho comparou o volume de modelos tridimensionais gerados por diferentes formas de engenharia reversa: escaneamento tridimensional superficial, tomografia computadorizada helicoidal com uma fileira de detectores, com multidetectores de 4 canais, com multidetectores de 128 canais e tomografia computadorizada de feixe cônico. Foram utilizadas oito mandíbulas secas humanas, as quais foram submetidas aos referidos exames de aquisição de imagem. Os arquivos dos exames feitos pelos tomógrafos foram salvos no formato DICOM em mídia eletrônica e processados no programa 3D Doctor® (Able Corporation, Massachusetts, EUA) para a obtenção das reconstruções virtuais tridimensionais, nas quais foram utilizadas, ainda, duas formas diferentes de segmentação: all boundary e outline only. Todos os modelos foram salvos no formato standard triangle language (STL) e comparados volumetricamente entre si. Concluiu-se que as diferentes formas de engenharia reversa geraram modelos virtuais tridimensionais cujos volumes não apresentaram diferença estatisticamente significante, independente da técnica de segmentação utilizada. Quanto ao uso de diferentes técnicas de segmentação em imagens obtidas por um mesmo tomógrafo houve estatisticamente significante no volume dos modelos virtuais tridimensionais gerados.
259

Avaliação de caninos superiores não-irrompidos por meio de tomografia computadorizada de feixe cônico

Santos, Ludmilla Mota da Silva 30 November 2011 (has links)
Submitted by Barroso Patrícia (barroso.p2010@gmail.com) on 2013-04-04T19:29:11Z No. of bitstreams: 1 Ludmilla-Pronto.pdf: 908861 bytes, checksum: 05871384ea1af73b3b9f3d1959b2b8ad (MD5) / Made available in DSpace on 2013-04-04T19:29:11Z (GMT). No. of bitstreams: 1 Ludmilla-Pronto.pdf: 908861 bytes, checksum: 05871384ea1af73b3b9f3d1959b2b8ad (MD5) Previous issue date: 2012 / Os caninos superiores são o segundo grupo de dentes que mais sofrem impactação. A etiologia da sua ocorrência é multifatorial e continua incerta. Os exames de imagem (planas e volumétricas) são utilizados para o diagnóstico da localização dos caninos impactados, assim como para o planejamento do tratamento. Este trabalho tem o objetivo de determinar as características dos caninos não-irrompidos e suas relações com estruturas adjacentes, por meio de imagens de tomografia computadorizada de feixe cônico. Foram avaliadas as imagens de tomografia computadorizada de 65 pacientes, totalizando 79 caninos nãoirrompidos, oriundas do banco de imagens do laboratório de tomografia computadorizada de feixe cônico (LAB TCFC 3D) da Faculdade de Odontologia, da Universidade Federal da Bahia. Os parâmetros avaliados foram: distribuição por sexo; ocorrência unilateral ou bilateral; localização em relação ao dente incisivo lateral adjacente; relação com raízes dos dentes adjacentes (presença ou ausência de reabsorção radicular) e grau da raiz quando presente (leve, moderada ou severa); anatomia radicular; espessura do espaço do folículo pericoronário e possíveis condições locais associadas. A maioria dos pacientes era do sexo feminino (70,8%). Houve uma predileção da impactação dos caninos por palatino (67,1%). Os caninos não-irrompidos provocaram reabsorção das raízes dos dentes adjacentes em 69,6% dos casos. A reabsorção radicular foi mais frequente quando os caninos estavam impactados por vestibular ou por palatino, do que quando impactados no centro do rebordo alveolar. A tomografia computadorizada de feixe cônico demonstrou ser uma ferramenta de imagem adequada para a avaliação dos caninos superiores não-irrompidos. / Universidade Federal da Bahia, Instituto de Ciências da Saúde
260

Indicadores antropométricos associados à hipertrigliceridemia na predição da gordura visceral

Oliveira, Carolina Cunha de 21 May 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-05-09T17:16:47Z No. of bitstreams: 1 Mestrado_Nut_Carolina Oliveira.pdf: 865567 bytes, checksum: 26e1702d75ab35e96dc9cbaa3de4ca5c (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-05-21T03:25:18Z (GMT) No. of bitstreams: 1 Mestrado_Nut_Carolina Oliveira.pdf: 865567 bytes, checksum: 26e1702d75ab35e96dc9cbaa3de4ca5c (MD5) / Made available in DSpace on 2013-05-21T03:25:18Z (GMT). No. of bitstreams: 1 Mestrado_Nut_Carolina Oliveira.pdf: 865567 bytes, checksum: 26e1702d75ab35e96dc9cbaa3de4ca5c (MD5) / O acúmulo de gordura na região abdominal, especialmente a gordura visceral, está fortemente associado a alterações cardiometabólicas, sendo importante estimar o depósito de gordura visceral para prevenir o desenvolvimento de doenças. Métodos alternativos, como a associação de indicadores antropométricos e hipertrigliceridemia são apontados como capazes de melhor estimar o acúmulo de gordura visceral pela sua relação com esse tecido. Objetivo: Avaliar o desempenho de indicadores antropométricos na predição de gordura visceral quando associados à hipertrigliceridemia em homens e mulheres. Método: Estudo transversal, composto por 192 indivíduos, estratificados por idade, sexo e massa corporal. Foram realizadas tomografia computadorizada, avaliações antropométrica (Circunferência da Cintura – CC, Diâmetro Abdominal Sagital – DAS e Razão Cintura-Quadril – RCQ) e bioquímica (colesterol total e frações, triglicerídeos – TG, ácido úrico). Foi realizada análise descritiva, correlação de Pearson e Regressão Linear Múltipla. Resultados: Os indicadores antropométricos apresentaram alta correlação com a área de tecido adiposo visceral (TAV) (p=0,000). Independente do nível sérico de TG, indivíduos com indicadores antropométricos elevados apresentaram excesso de área de TAV (p<0,05). Para cada aumento de um centímetro na medida do DAS, há um aumento médio de 12,46cm² de área de TAV. Conclusão: A presença do TG mostrou não melhorar o desempenho dos indicadores antropométricos. O DAS e CC foram os indicadores que melhor explicaram a variabilidade na área TAV, possibilitando identificar indivíduos de risco para desenvolvimento de doenças cardiovasculares. / Salvador

Page generated in 0.0555 seconds