Spelling suggestions: "subject:"tomografia"" "subject:"lomografia""
321 |
Desenvolvimento de uma metodologia para controle da qualidade de imagens em equipamentos de tomografia computadorizada de feixe cônico odontológicoHoffmann, Elias Cantarelli January 2015 (has links)
Made available in DSpace on 2015-06-23T02:05:43Z (GMT). No. of bitstreams: 1
000470853-Texto+Completo-0.pdf: 2786282 bytes, checksum: 202437712e592d5d1814790a5c93c608 (MD5)
Previous issue date: 2015 / Cone-beam CT (CBCT) systems have been used for diagnostic radiology of head and neck, and dentomaxillofacial surgery applications. Different dental CBCT devices are being developed and released, with a wide variability of exposure parameters and fields of view. Although they have sufficient diagnostic quality, some of the drawbacks of the dental CBCT devices are their inability of discriminating soft tissue because of its low contrast resolution, and the inaccuracy to give information about soft tissue quality. Standard quality control procedures and phantoms for conventional CT are not fully applicable for CBCT devices. Furthermore, there is a lack of quantitative methods for image quality analysis suitable for dental CBCT. The aim of this study was to develop and implement a feasible methodology for image quality analysis for different dental CBCT devices. The methodology was based on conventional CT quality control procedures, and adapted to overcome the limitations of dental CBCT. A prototype phantom was specially designed to allow the acquisition of image quality parameters relevant for dental imaging. CBCT devices were divided into categories for the analysis, related to their Field of View (FOV): Small Field of View (SFOV) and Full Field of View (FFOV).The following image quality parameters were evaluated: filed uniformity, image noise, contrast-to-noise ratio, CT number accuracy, artifacts, spatial resolution and geometric distortion. Applicability of the methodology was assessed using one SFOV and four different FFOV CBCT devices. Large differences in image quality performance were seen between the CBCT devices. Furthermore, a CT number calibration method was developed and tested, which enables CBCT devices for bone density evaluation. Concluding, a new methodology was implemented and proved to be viable for use on different CBCT devices with a variability of fields of view. Based on the evaluations, the prototype phantom will be optimized and validated for quality assurance on CBCT devices. / Sistemas de tomografia computadorizada por feixe cônico ou CBCT têm sido utilizados para radiologia diagnóstica de cabeça e pescoço, e aplicações em cirurgia bucomaxilofacial. Diferentes CBCT odontológicos estão sendo desenvolvidos e disponibilizados, com uma grande variabilidade dos parâmetros de exposição e campos de visão. Embora tenham qualidade diagnóstica suficiente, algumas das desvantagens dos CBCT odontológicos são a sua incapacidade de discriminar tecidos moles devido a limitações na resolução de contraste e a imprecisão para fornecer informações sobre a qualidade dos tecidos. Procedimentos e simuladores de controle de qualidade para a tomografia computadorizada convencional não são plenamente aplicáveis para equipamentos CBCT. Além disso, há uma falta de métodos quantitativos para a análise da qualidade da imagem adequada para CBCT odontológico. O objetivo deste estudo foi desenvolver e implementar uma metodologia viável para análise de qualidade de imagens em diferentes modelos de equipamentos CBCT odontológicos. A metodologia foi baseada em procedimentos de controle de qualidade de tomógrafos convencionais, e adaptada para superar as limitações da CBCT dentária. Um protótipo de simulador foi projetado especialmente para permitir a aquisição de parâmetros de qualidade de imagem relevantes para a imagem dentária. Os equipamentos CBCT foram divididos em categorias para a análise, relacionadas com seu campo de visão (FOV): pequeno campo de visão (SFOV) e amplo campo de visão (FFOV). Os seguintes parâmetros de qualidade de imagem foram avaliados: uniformidade de campo, o ruído da imagem, razão contraste-ruído, acurácia do número CT, artefatos, resolução espacial e distorção geométrica.A aplicabilidade da metodologia foi avaliada usando um CBCT SFOV e quatro FFOV diferentes. Grandes diferenças no desempenho da qualidade de imagem foram observadas entre os equipamentos. Um método de calibração do número CT foi desenvolvido e testado, permitindo que os equipamentos CBCT possam avaliar a densidade óssea. Concluindo, uma nova metodologia foi implementada e mostrou-se viável para utilização em equipamentos CBCT odontológicos com uma variedade de campos de visão. Com base nas avaliações, o simulador protótipo poderá ser otimizado e validado para garantia da qualidade em equipamentos CBCT.
|
322 |
Alteração da posição e remodelação dos côndilos mandibulares após cirurgia ortognática: estudo clínico por meio de tomografia computadorizadaMelo, Marcelo Fernandes Santos January 2014 (has links)
Made available in DSpace on 2015-10-16T02:03:48Z (GMT). No. of bitstreams: 1
000475702-Texto+Completo-0.pdf: 1550621 bytes, checksum: 0c7df03438a51b55173890c20f0cec58 (MD5)
Previous issue date: 2014 / Purpose: The aim of this study was to evaluate three-dimensional displacements and rotational changes of the mandibular condyles in patients with dentofacial deformities underwent bimaxillary orthognathic surgery, through of computerized cone beam tomography (CBCT) and tools and generation and superimposition softwares of virtual 3D models. Materials and methods: The retrospective study used pre CBCT pre- (T0) and postoperative (T1) after 6 months of bimaxillary orthognathic surgery of 20 patients with skeletal malocclusion, equally divided into two groups (10 Class III and 10 Class II of Angle). An automatic superimposition method based on the gray scale of each voxel in the skull base was used to register and render the virtual 3D models of the mandibular condyles. The displacements were visualized and quantified in color-coded maps generated from the calculation of the distances between the closest points of two surfaces (representatives of different times, T0-T1) and by semitransparenct overlays of 3D virtual models pre and post surgical. The changes were quantified on 5 different surfaces of the condyle and were only recorded with values greater than 1. 5 mm. To compare the two measurements (T0-T1), because they are paired data, we used the student t test for differences between the two groups Class II and Class III. The level of significance used was p <0. 05. Demographic data for the two groups showed a normal distribution by the Kolmogorov-Smirnov test, and its variables were compared using the Student t test for paired samples. Results: The Class III group presented greater displacement outward or bone apposition on the posterior surface and greater displacement inward or bone resorption on the upper surface of the condyle. The Class II group presented greater displacement outward or bone apposition on the upper surface and greater displacement inward or bone resorption on the lateral pole of the condyle. For the Class III group, the predominant rotational displacements were medial roll (10%), medial yaw (15%), pitch down (25%). As for the Class II group, were the predominant medial and lateral roll (5%), medial yaw (20%), pitch up (45%).Conclusion: The study confirms that postsurgical adaptations occur after 6 months of bimaxillary orthognathic surgery, and the displacements and rotations condylar larger than 1. 5 mm were observed in both groups. The Class II group showed the greatest change condylar, though neither group showed dysfunctional condylar bone remodeling, keeping the postsurgical adaptation relatively stable. / Objetivo: O objetivo deste estudo foi avaliar tridimensionalmente os deslocamentos e alterações rotacionais dos côndilos mandibulares em pacientes com deformidades dentofaciais submetidos à cirurgia ortognática bimaxilar, através de Tomografia Computadorizada Cone Beam (TCCB) e de ferramentas e softwares de geração e superposição de modelos virtuais 3D. Materiais e métodos: O estudo retrospectivo usou TCCB pré (T0) e pós-operatórias (T1) após 6 meses de cirurgia ortognática bimaxilar de 20 pacientes com maloclusão esquelética, divididos igualmente em dois grupos (10 Classe III e 10 Classe II de Angle). Um método de superposição automático baseado na escala de cinza de cada voxel na base do crânio foi usado para registrar e renderizar os modelos virtuais 3D dos côndilos mandibulares. Os deslocamentos foram visualizados e quantificados em mapas de codificação coloridos gerados a partir do cálculo das distâncias entre os pontos mais próximos de duas superfícies (representantes de tempos distintos - T0 e T1) e por sobreposição por semitransparência dos modelos virtuais 3D pré e pós cirúrgicos. As alterações foram quantificadas em 5 diferentes superfícies do côndilo e só foram registradas com valores maiores do que 1,5 mm. Para a comparação entre as duas medições realizadas (T0-T1), por se tratarem de dados pareados, foi utilizado o teste t student para as diferenças entre os dois grupos Classe II e Classe III. O nível de significância usado foi p> 0,05. Os dados demográficos para os dois grupos mostraram uma distribuição normal, segundo o teste de Kolmogorov-Smirnov, e suas variáveis foram comparadas com o teste t student para amostras pareadas. Resultados: O grupo Classe III apresentou maior deslocamento para fora (outward) ou aposição óssea na superfície posterior e maior deslocamento para dentro (inward) ou reabsorção óssea na superfície superior do côndilo. O grupo Classe II apresentou maior deslocamento para fora (outward) ou aposição óssea na superfície superior e maior deslocamento para dentro (inward) ou reabsorção óssea no pólo lateral. Para o grupo Classe III, os deslocamentos rotacionais predominantes foram o roll medial (10%), yaw medial (15%), pitch para baixo (25%). Já para o grupo Classe II, os predominantes foram o roll medial e lateral (5%), yaw medial (20%), pitch para cima (45%).Conclusão: O estudo comprova que adaptações pós-cirúrgicas ocorrem após 6 meses de cirurgia ortognática bimaxilar, e os deslocamentos e rotações condilares maiores do que 1,5 mm foram observadas nos dois grupos. O grupo Classe II apresentou maior alteração condilar, entretanto nenhum grupo apresentou remodelação óssea condilar disfuncional, mantendo a adaptação pós-cirúrgica relativamente estável.
|
323 |
Solução do problema inverso da tomografia por impedância elétrica utilizando o simulated annealing: uma nova abordagemMartins, Jefferson Santana January 2016 (has links)
Made available in DSpace on 2016-04-28T12:14:29Z (GMT). No. of bitstreams: 1
000478363-Texto+Completo-0.pdf: 599 bytes, checksum: cd92f330653a1fb83002029c6db7d91c (MD5)
Previous issue date: 2016 / Image reconstruction in electrical impedance tomography (EIT) deals with an ill-posed and nonlinear inverse problem. It intends to minimize the difference between simulated (virtual) object data and data from a non simulated (real) object. In this paper, a new approach to the Simulated Annealing method applied to reconstruction of EIT images is described. The main advantage in this approach is that all conductivity parameters are updated simultaneously. Other methods that employ Simulated Annealing to the problem of EIT evaluate each conductivity parameter individually resulting in high computational cost. The algorithm was tested both with computationally generated data and with measurements performed on a physical simulation tank. In both cases, the method was able to make data inversion, determining the position, the dimensions and the conductivity of materials in an opaque object plane. / O problema de reconstrução da tomografia por impedância elétrica (TIE) é um problema de otimização inverso, não linear e mal-condicionado, no qual se objetiva minimizar a diferença entre dados medidos e calculados através de um modelo numérico. No presente trabalho, é descrita uma nova abordagem do método de recozimento simulado aplicado à reconstrução de imagens de TIE. A principal vantagem do algoritmo apresentado é que todos os parâmetros de condutividade do domínio são atualizados conjuntamente. Outros métodos que empregam o recozimento simulado para a solução do problema da TIE avaliam individualmente cada parâmetro de condutividade, tendo, por isso, grande custo computacional. O método proposto foi testado com dados gerados computacionalmente e com medidas realizadas em um tanque de simulação física. Em ambos os casos, ele pôde fazer a inversão dos dados, sendo capaz de determinar a posição, as dimensões e a condutividade de diferentes materiais em um plano transverso de um objeto opaco.
|
324 |
Testes convencionais e empregando Micro-CT na avaliação de propriedades físico-químicas de materiais retrobturadores e cimentos endodônticos /Torres, Fernanda Ferrari Esteves. January 2016 (has links)
Orientador: Mário Tanomaru Filho / Banca: Idomeo Bonetti Filho / Banca: Yara Teresinha Corrêa Silva Sousa / Resumo: Materiais endodônticos devem apresentar propriedades físico-químicas segundo ISO e ADA. Novas metodologias empregando Microtomografia Computadorizada (Micro-CT) podem ser utilizadas. Este estudo foi dividido em quatro capítulos: Capítulo 1: avaliou MTA Angelus (MTA), Biodentine (BIO) e óxido de zinco e eugenol (OZE) utilizando testes convencionais e com Micro-CT. Solubilidade e alteração dimensional basearam-se em Carvalho-Junior et al. (2007). Capacidade de preenchimento e alteração volumétrica foram avaliadas por Micro-CT. Foram realizados os testes ANOVA e Tukey com 5% de significância. BIO e MTA apresentaram maior estabilidade dimensional. OZE e BIO mostraram maior capacidade de preenchimento. Aos 7 dias a solubilidade foi maior para BIO e a alteração volumétrica foi semelhante para os materiais. Aos 30 dias, a solubilidade foi semelhante para os materiais, porém a alteração volumétrica foi maior para BIO que MTA. BIO apresenta capacidade de preenchimento, porém maior alteração volumétrica. Micro-CT pode complementar testes convencionais. Capítulo 2: Nova técnica para avaliação do escoamento foi proposta com Micro-CT. MTA, OZE e BIO foram avaliados segundo ISO 6876/2002 e pela técnica proposta. Placa de vidro com cavidade central e 4 canaletas foi confeccionada. Cada material foi colocado sobre a cavidade central e nova placa de vidro posicionada. O conjunto foi escaneado por meio de Micro-CT. O escoamento foi calculado pela mensuração linear (mm) em cada canaleta. O pre... (Resumo completo, clicar acesso eletrônico abaixo) / Abtract: Endodontic materials have to present physicochemical properties according to ISO and ADA. New methodologies using microcomputed tomography (Micro-CT) can be used. This study was divided into four chapters: Chapter 1: evaluated MTA Angelus (MTA), Biodentine (BIO) and zinc oxide and eugenol (ZOE) using conventional and Micro-CT tests. Solubility and dimensional stability based on Carvalho-Junior et al. (2007). Filling ability and volumetric change were evaluated by Micro-CT. ANOVA and Tukey test with 5% significance were performed. BIO and MTA had greater dimensional stability. ZOE and BIO showed greater filling ability. At 7 days solubility was greater for BIO and volumetric change was similar for materials. At 30 days, the solubility was similar to the materials, but the volumetric change was greater for BIO than MTA. BIO presents filling ability, but higher volumetric change. Micro-CT can complement conventional tests. Chapter 2: New technique to assess the flow was proposed using Micro-CT. MTA, ZOE and BIO were evaluated according to ISO 6876/2002 and the proposal method. A glass device with a central cavity and four grooves was made. Each material was placed over the central cavity and a new glass device was positioned. The set was scanned by Micro-CT. The flow was calculated by linear measurement (mm) on each groove. The central volumetric filling (CVF) in mm³ was calculated in the central cavity and the lateral volumetric filling (LVF) was measured by the average filling in the side grooves up to 2 mm. The results were submitted to ANOVA and Tukey, with 5% level. ZOE was the material with higher flow by ISO methodology. Using Micro-CT, MTA and ZOE showed higher linear flow. CVF was similar to materials. However, LVF was higher to Biodentine than ZOE. It is concluded that MTA and ZOE have better linear... (Complete abstract electronic access below) / Mestre
|
325 |
Mensurações goniométricas, radiográficas e tomográficas dos membros de cachorros-do-mato (Cerdocyon thous, Linnaeus, 1766)Castilho, Maíra Sales January 2016 (has links)
Orientador: Sheila Canevese Rahal / Resumo: O trabalho teve por objetivo avaliar, em cachorros-do-mato, valores goniométricos das articulações dos membros torácicos e pélvicos, com emprego de goniômetro universal de plástico; e valores radiográficos ou tomográficos de ângulos articulares dos membros pélvicos, bem como a proporção do comprimento do ligamento patelar (L) com o comprimento da patela (P). Para tanto, foram utilizados 15 cachorros-do-mato clinicamente saudáveis, com idade acima de 1 ano. A amplitude de movimento das articulações do carpo, cotovelo e ombro para o avaliador 1 foram 138°, 108° e 118°, e das articulações do tarso, joelho e coxofemoral foram 96°, 118° e 84°. Para o Avaliador 2 a amplitude de movimento das articulações do carpo, cotovelo e ombro foram 138°, 110° e 118°, e das articulações do tarso, joelho e coxofemoral foram 94°, 114° e 88°. Não foram detectadas diferenças estatisticamente significantes entre os lados nas mensurações radiográficas. Os valores médios obtidos para os ângulos anatômicos femoral proximal lateral e distal lateral foram 95,43° e 92,75°, e para os ângulos mecânicos femoral proximal lateral e distal lateral foram 93,39° e 96,75°. Os ângulos de inclinação pelos métodos de Tomlinson, Hauptman A e Hauptman B foram 133,80°, 147,32° e 128,63°. Os ângulos de Norberg e de inclinação do platô tibial foram 107,57° e 18,77°. A proporção L:P foi de 1,99 (± 0,13). Escore da subluxação dorsolateral, Ângulo da margem do centro lateral, Ângulo da borda acetabular dorsal, Índice da dist... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate goniometric values of the forelimb and hind limb joints by means of a standard plastic goniometer, radiographic values or computed tomographic values of articular angles of the hind limbs, and ratio of patellar ligament length to patellar length (L:P) in crab-eating foxes. Fifteen clinically healthy crab-eating foxes above 1 year of age were used. The range of motion of the carpus, elbow and shoulder for evaluator 1 were 138°, 108° and 118°, and for the tarsus, stifle and hip were 96°, 118° and 84°. The range of motion of the carpus, elbow and shoulder for evaluator 2 were 138°, 110° and 118°, and for the tarsus, stifle and hip were 94°, 114° and 88°. No statistically significant differences were observed between the sides in the radiographic measurements. The anatomic lateral proximal femoral angle and anatomic lateral distal femoral angle had mean values of 95.43° and 92.75°. The mechanical lateral proximal femoral angle and mechanical lateral distal femoral angle had mean values of 93.39° and 96.75°. The angle of inclination by Tomlinson, Hauptman A and Hauptman B methods were 133.80°, 147.32°, and 128.63°. The Norberg angle and slope angle of the tibial plateau were 107.57° and 18.77°, respectively. The L:P value was 1.99 (± 0.13). The dorsolateral subluxation score, lateral center edge angle, dorsal acetabular rim angle, and center distance index measured on the CT images had mean values of were 60.79°, 98.25°, 13.47°, and 0.16. In c... (Complete abstract click electronic access below) / Mestre
|
326 |
Análise tridimensional das alterações dento-alveolares em molares superiores após o uso do aparelho de Herbst /Kameyama, Daniela Cristina. January 2014 (has links)
Orientador: Dirceu Barnabé Raveli / Banca: Luiz Gonzaga gandini Jr. / Banca: Jorge Abrão / Resumo: Este estudo teve como objetivo avaliar tridimensionalmente a altura e espessura óssea alveolar e alterações dentárias no sentido vertical e transversal na maxila após o uso do aparelho de Herbst. A amostra prospectiva foi composta por 23 indivíduos brasileiros, leucodermas, de ambos os gêneros, com idade média de 15.76 ± 1.75 anos, apresentando a má oclusão de Classe II divisão 1, com deficiência mandibular que foram tratados com o aparelho de Herbst por um período de 8 meses. Para essa avaliação foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) obtidas antes (T1) e depois do tratamento (T2) para análise e medição das alterações estruturais: altura e espessura óssea alveolar na região de molares e, alterações dentárias no sentido vertical de molares e transversal (distância e inclinação intermolar). O erro do método foi avaliado pelo Coeficiente de Correlação Intraclasse (ICC) e o teste t pareado foi usado para comparar as medidas obtidas em T1 e T2 com nível de significância de 5%. Os resultados mostraram que o ICC foi elevado para todas as medições (0,95). Houve aumento da altura (0,37mm) e espessura óssea alveolar apenas na lingual da região dos molares superiores sendo que com os terços médio (0,45mm) e apical (0,58mm) tiveram resultados mais significativos. Quanto à relação dentária teve diminuição significativa da angulação intermolar com média de 4,6° (p<0,05). Concluímos que o tratamento ortodôntico com aparelho de Herbst levou a alterações apenas na lingual da altura e espessura óssea alveolar e na angulação intermolar da arcada superior. / Abstract: This study aimed to evaluate three-dimensionally the height and thickness of alveolar bone and dental changes at vertical and crossectional direction after use of Herbst appliance. The prospective sample was composed of 23 Caucasian Brazilian individuals of both genders, with mean age: 15.76 ± 1.75 years, presenting Class II division 1 malocclusion with mandibular deficiency and treated with Herbst appliance during a period of 8 months. Cone-beam computed tomography images were obtained before (T1) and after treatment (T2) to analyse and measure the structures: height and thickness of alveolar bone at the molar region and dental changes at vertical of the molars and crossectional direction (intermolar distance and inclination). The error of the method evaluated by the Intraclass Correlation Coefficient (ICC) and Paired t-tests were used to compare T1 and T2 with significance level of 5%. The results showed that the ICC was high for all measurements (0.95). There was increase in height (0.37 mm) and alveolar bone thickness only at the lingual region of the upper molars with more significant result at the middle third (0.45 mm) and apical region (0.58 mm). Regarding dental changes, there was a significant decrease at intermolar angulation mean of 4.6° (p<0.05). It was concluded that orthodontic treatment with Herbst appliance led to changes in height and alveolar bone thickness at the lingual and intermolar angulation in the upper arch. / Mestre
|
327 |
Análise da locomoção e estudos por imagens em porcos com sindactilia /Justolin, Pedro Luis Trevizan. January 2015 (has links)
Orientador: Sheila Canevese Rahal / Banca: Maria Jaqueline Mamprim / Banca: Cássio Ricardo Auada Ferrigno / Resumo: O objetivo do presente estudo foi caracterizar, por exames de imagem, uma população de porcos naturalmente portadores de sindactilia, bem como avaliar-lhes os parâmetros cinéticos e têmporo-espaciais. Foram utilizados 10 miniporcos brasileiros (Sus domesticus), não castrados, com idade entre 6 e 8 meses, dos quais se constituíram dois grupos experimentais. O Grupo 1 foi composto de cinco animais clinicamente saudáveis, com massa corpórea entre 10,5 e 18,5 kg, enquanto o Grupo 2, por animais portadores de sindactilia, com massa corpórea entre 7,5 e 18,0 kg. Em ambos os grupos, efetuaram-se exames radiográficos e tomográficos dos membros torácicos e pélvicos, além da análise da locomoção com o emprego de plataforma de pressão. Pelos exames de imagem, os animais do grupo 2 apresentaram os quatro membros comprometidos. Nos membros torácicos, detectaram-se dois animais de membros com sindactilia complexa 1 e oito com sindactilia complexa 2. Nos membros pélvicos, observaram-se quatro indivíduos com sindactilia simples, um com sindactilia complexa 1 e cinco com sindactilia complexa 2. Entre os grupos, não se constatou diferença estatística nos valores cinéticos e têmporo-espaciais, bem como nos índices de simetria. A superfície plantar e a superfície palmar dos porcos clinicamente normais tinham dois picos de pressão, ao passo que os com sindactilia tinham apenas um pico de pressão. Foi possível concluir que, na população avaliada, o tipo de sindactilia mais comum foi a complexa 2 e, a despeito das alterações, a maioria dos dados obtidos com o uso da plataforma de pressão foi similar à dos animais normais / Abstract: Ten Brazilian mini pigs (Sus domesticus), from 6 to 8 months old, were divided into two groups: Group 1 - five healthy animals weighing from 10.5 to 18.5 kg and Group 2 - five animals with syndactyly weighing from 7.5 to 18.0 kg. In both groups radiographic and computed tomography studies were performed in the fore and hind limbs. Moreover, gait analysis was performed by using pressure sensing walkway. Imaging studies showed that the animals had involvement of all limbs. In particular, one limb with complex-1syndactyly and eight limbs with complex-2 syndactyly were detected in the forelimbs. In the hind limbs, four limbs with simple syndactyly, one limb with complex-1 syndactyly and five limbs with complex-2 syndactyly were observed. There were no significant differences of the kinetic and temporospatial values between groups as well as in the symmetry indices. The plantar surface of the feet and palmar surface of the hands of the clinically healthy pigs had two peak pressure plots whereas only one peak pressure plot was observed in pigs with syndactyly. In conclusion, in the evaluated population the most common type of syndactyly was complex-2 and despite of the lesions, most of data obtained using pressure sensing walkway was similar to those of normal pigs / Mestre
|
328 |
Estudo in vitro para avaliação e validação de medidas lineares na tomografia computadorizada 3D cone beam comparadas às medidas do crânio in situ /Matai , Caio Vinicius Bardi. January 2009 (has links)
Orientador: Adriano Marotta Araújo / Banca: Jefferson Luis OshiroTanaka / Banca: Horácio Faig Leite / Resumo: As tomografias computadorizadas (TC) tridimensionais (3D) solucionaram em grande parte as inconveniências da sobreposição de acidentes anatômicos laterais comuns (dependendo da direção de incidência dos raios X) nas radiografias realizadas com o indivíduo em perfil. Também eliminou-se a sobreposição de imagens comuns a métodos radiográficos 2D. O propósito neste trabalho foi comparar a precisão das mensurações 3D na identificação de estruturas craniofaciais e ampliar o conhecimento da classe odontológica sobre o uso da Tomografia computadorizada 3D "cone beam' (TCCB) como ferramenta de auxílio no diagnóstico das estruturas faciais. Foram utilizados cinco crânios secos, pertencentes à Disciplina de Anatomia da Faculdade de Odontologia de São José dos Campos - UNESP. Os crânios foram fixados em relação central dos côndilos com máxima intercuspidação dos dentes. Todos os crânios apresentaram seus pontos cefalométricos demarcados com identificadores metálicos e escaneados no tomógrafo cone beam Newtom, sendo que todas as medidas lineares foram comparadas com as medidas in situ mensuradas com o auxílio do paquímetro digital. Após validação do erro do operador, os dados obtidos foram comparados e submetidos a estatística descritiva e à análise de Wilcoxon. Os resultados mostraram que 40% das medidas tiveram uma diferença menor que 0,16mm, 85% apresentaram acurácia abaixo do valor de 0,58mm e que menos de 3% das medidas tiveram diferença de valores acima de 1mm. O teste de Wilcoxon não encontrou nenhuma diferença estatisticamente significante entre os métodos. Concluímos que a TCCB é um método preciso para obtenção de medidas linear de estruturas do crânio quando comparada as mesmas mensurações realizadas in situ(AU) / Abstract: The three-dimensional (3D) computed tomography (CT) overcame many of the hassles of overlapping anatomical accidents common in lateral radiographs taken with the individual in profile. Also eliminated the overlap of images common to 2D radiographic methods. The purpose of this study was to compare the accuracy of 3D measurements in the identification of craniofacial structures and expanding the knowledge of the class on the use of dental computed tomography 3D cone beam (CBCT) as a tool to aid in the diagnosis of facial structures. The tests were in situ, on a five dry skulls, belonging to the Discipline of Anatomy, São José dos Campos Dental School- UNESP. The skulls were fixed on the central condyle with maximum intercuspation teeth. All of than had their skulls cephalometric points marked with metal identifiers and scanned with Newtom cone beam tomography. Linear measurements were compared with measures in situ measured using the digital caliper. After validation of operator error, the data were compared and subjected to descriptive statistics and analysis of Wilcoxon. The results showed that 40% have had a difference of less than 0.16 mm, 85% were below the accuracy of 0.58 mm and less than 3% of the difference in values were over 1 mm. The test of Wilcoxon found no statistically significant difference between the methods. We conclude that CBCT is a precise method for identifying and measuring the linear skull's structures when compared the same measurements performed with digital caliper in situ(AU) / Mestre
|
329 |
Avaliação das vias aéreas superiores após uso do aparelho Herbst, por meio de sobreposição tridimensional /Palomino-Gómez, Sandra Patricia. January 2015 (has links)
Orientador: Dirceu Barnabé Raveli / Banca: Ary sos Santos Pinto / Banca: Luiz Gonzaga Gandini Junior / Banca: Arnaldo Pinzan / Banca: Carlos Flores-Mir / Resumo: As mudanças nos padrões de respiração nasal afetam profundamente o crescimento craniofacial. Avanços tecnológicos, como a tomografia computadorizada de feixe cônico (TCFC), têm sido utilizados com o propósito de se observar tridimensionalmente a localização de diferentes estruturas do crânio, a face e o espaço aéreo faríngeo. Desta forma, é possível avaliar as alterações do espaço aéreo induzidas pelos aparelhos ortopédicos propulsores mandibulares. O intuito deste estudo foi avaliar as mudanças na faringe superior resultantes do avanço mandibular com aparelho Herbst, mediante análise do método de sobreposição de coordenadas tridimensionais matemáticas. A amostra deste estudo está composta por 24 pacientes, 10 do gênero feminino e 14 do gênero masculino (16,1 anos no início de tratamento), tratados por 8 meses com aparelho Herbst, sendo comparados com o grupo controle composto de 7 pacientes do gênero feminino (13,54 anos ao início do T1). Todos os indivíduos apresentavam má oclusão classe II divisão 1ª e já haviam passado pelo surto de crescimento pubertário (avaliados e pareados com radiografia de mão e punho). Os exames tomográficos foram realizados em dois tempos para cada paciente. A fase inicial foi realizada com a localização e identificação de 79 pontos anatômicos nos eixos: axial, coronal e sagital, sendo que 26 pontos anatômicos (base do crânio, maxila, mandíbula 37 vértebra e hióide) foram adotados para a análise final com auxílio do software AVIZO®. Após o processo de calibração, cada variável foi mensurada três vezes. A análise estatística dos dados foi realizada por meio do Test de Levane e teste T de Student ao nível de significância de 5 %. A confiabilidade das medidas apresentaram boa replicabilidade (ICC ≥ 0,921), com exceção da borda superior de vértebra cervical 3 e dos pontos inferiores da coana... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Changes in nasal breathing pattern affect the craniofacial growth. Technological advances, such as Cone beam computed tomography (CBCT), have been used in order to observe three-dimensionally (3D) the skull, face and pharyngeal airway space. The latter, with possible assessment of airway changes induced by orthopedic activators. The aim of this study was to evaluate the changes of the upper airway space resulted from mandibular advancement with Herbst appliance through superposition method of mathematical 3D coordinates. The sample was composed of 24 patients, 10 females and 14 males (16.1 years at the start of treatment - T1) treated for 8 months with Herbst appliance, and compared with a group control composed of 7 females (13.54 yrs at T1). Individuals of the samples were patients with malocclusion Class II division 1, already been through the pubertal growth spurt. The growth sprunt was assessment with hand/wrist radiographs. For each patient, CBCT scans were performed in two stages. The initial phase was conducted by location and identification of 79 anatomical points in the shaft, axial, coronal and sagittal views. Twenty-six anatomical points (skull base, maxilla, vertebra and Hyoid jaw) were adopted for the final analysis using Avizo analysis software®. After calibration of the examiner, each variable was measured three times. The statistical analysis was performed using Levene Test and t-Test with 39 significance level of 5%. The reliability of the measurements showed good reproducibility (ICC ≥ 0.92), exception were the top edge of cervical vertebra 3 and lower border of the Choanae. The results indicated statistical significance in axis Z for PNS (p = 04) compared to control group and for to tip of the epiglottis (p=0.02) compared with control group. Other structures, which were statistically significant, were the left portion of the greater cornu of hyoid...(Complete abstract electronic access below) / Doutor
|
330 |
Mielografia e tomografia computadorizada de afecções compressivas da medula espinhal em cães /Avante, Michelle Lopes. January 2015 (has links)
Orientador: Júlio Carlos Canola / Banca: Paola Castro Moraes / Banca: Rosana Zanatta / Resumo: Lesões da medula espinhal ocorrem frequentemente em pequenos animais em razão de causas exógenas ou endógenas. A lesão medular é classificada em extradural, intradural-extramedular e intramedular. Este estudo tem como objetivo determinar as lesões que envolvem a medula espinhal e seus diferentes achados e frequências à mielografia. Paralelamente, um outro estudo com seis pacientes com exames inconclusivos à mielografia foram submetidos à tomografia computadorizada contrastada e seus achados foram confrontados com a mielografia. Neste estudo foram reavaliados 154 casos de cães com suspeita clínica neurológica envolvendo a medula espinhal, os quais foram submetidos a exames radiográficos convencionais e à mielografia com composto iodado não iônico no período de 2008 a 2012. Os exames imaginológicos foram desenvolvidos no Setor Diagnóstico por Imagem do Hospital Veterinário "Governador Laudo Natel" da Faculdade de Ciências Agrária e Veterinária de Jaboticabal - Unesp. Entre as diferentes raças de cães, a Teckel foi mais acometida com a apresentação de 58 pacientes (38%). A faixa etária de maior ocorrência foi de cinco a oito anos, totalizando 67 cães (43,5%). A coluna cervical foi o segmento de maior ocorrência das lesões encontradas com 88 lesões (44%). A localização mais frequente das lesões foi extradural, correspondente a 191 lesões do total analisado (95,5%) e nove lesões foram intradurais-extramedulares (4,5%). Das lesões extradurais, 175 (91,6%) foram de origem degenerativa do disco intervertebral, protrusão/extrusão. Com exceção dos 154 casos, no primeiro semestre de 2013, em seis outros pacientes foram realizados, sequencialmente, mielografias e tomografia computadorizada. Nestes casos as lesões foram em região cervical: três casos (50%), dois na região lombar (33%) e um toracolombar (17%). Todas as lesões foram extradurais, três casos de extrusão do disco (50%), dois de... / Abstract: Spinal cord injuries often occur in small animals due to exogenous or endogenous causes. Spinal cord injury is classified into extradural, intradural-extramedullary and intramedullary. This study aims to determine the lesions involving the spinal cord and its findings and different frequencies to myelography. At the same time, another study with six patients with inconclusive examinations to myelography underwent computed tomography contrasting and their findings were compared with myelography. In this study were reassessed 154 cases of dogs with neurological clinical suspicion surrounding the spinal cord, which underwent conventional radiographs and myelography with nonionic iodinated compound in the period 2008 to 2012. The imaging studies were developed in Sector Diagnostic Imaging Veterinary Hospital "Governador Laudo Natel" of the Faculdade de Ciências Agrárias e Veterinárias Jaboticabal - Unesp. Among the different breeds of dogs, the Teckel were the most affected with the presentation of 58 patients (38%). The age group most frequent was 5-8 years, totaling 67 dogs (43.5%). The cervical column was the most frequent segment of the lesions found in 88 lesions (44%). The most common location of lesions was extradural corresponding to lesions of the total analyzed 191 (95.5%) and nine lesions were intradural extramedullary (4.5%). Extradural lesions of 175 (91.6%) were degenerative intervertebral disc protrusion / extrusion. Aside from the 154 cases in the first half of 2013, in six other patients were performed sequentially myelography and computed tomography. In these cases the lesions were in the neck: three cases (50%), two in the lower back (33%) and one thoracolumbar (17%). All lesions were extradural three cases of disc extrusion (50%), two protrusion (33.3%) and one for cancer/osteomyelitis (16.7%). The myelography permits, in most cases lead to a definitive diagnosis in patients with spinal cord compression injury. Computed ... / Mestre
|
Page generated in 0.0541 seconds