• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Avaliação tridimensional das alterações maxilomandibulares após expansão rápida de maxila assistida cirurgicamente /

Oliveira, Talles Fernando Medeiros de. January 2014 (has links)
Orientador: Ary dos Santos Pinto / Banca: Mario Francisco Real Gabrielli / Banca: Sergei Godeiro Fernandes Fernandes Rabelo Caldas / Resumo: A expansão rápida de maxila assistida cirurgicamente (ERMAC) é um tratamento eficaz nas deficiências transversais maxilares em adultos. Este estudo avaliou a influência de dois desenhos diferentes de osteotomia da parede lateral da maxila sobre as alterações transversais maxilares, de posicionamento mandibular e do relacionamento côndilo-fossa após ERMAC. Trinta pacientes adultos foram divididos em dois grupos de acordo com o desenho da osteotomia lateral. O grupo 1 (n = 16) foi submetido a osteotomia lateral realizada de forma horizontal e o grupo 2 (n = 14) submetido a osteotomia paralela ao plano oclusal com degrau no pilar zigomático. Tomografias computadorizadas de feixe cônico foram realizadas no pré-operatório (T1), após a expansão (T2) e seis meses após a expansão (T3). O desenho da osteotomia lateral não influenciou nas respostas maxilomandibulares após ERMAC. Nos dois grupos ocorreu aumento nas medidas transversais maxilares e rotação horária mandibular acompanhada de um deslocamento lateral imediatamente após a expansão. As alterações maxilares mostraram-se estáveis seis meses após a expansão, exceto a largura do assoalho nasal e inclinação dentária que apresentaram redução em T3. As alterações mandibulares tenderam a retornar aos valores próximos aos iniciais em T3. Não se observou alteração significativa no relacionamento côndilo-fossa em nenhum momento do estudo. O desenho da osteotomia lateral da maxila não influenciou nos resultados da ERMAC que ocorreu por meio de inclinação dos segmentos maxilares. O movimento rotacional e o deslocamento lateral da mandíbula são efeitos transitórios da ERMAC. / Abstract: Surgically assisted rapid maxillary expansion (SARME) is an effective treatment for maxillary transverse deficiency in adult patients. This study assessed the influence of two different osteotomy designs of the maxillary lateral wall on maxillary transverse changes, mandibular positioning and condyle fossa relationship after SARME. Thirty adult patients were divided into two groups according to the lateral osteotomy design: Group 1 (n = 16) underwent lateral osteotomy performed in a horizontal straight fashion and Group 2 (n = 14) underwent lateral osteotomy performed parallel to the occlusal plane with a step at the zygomatic buttress. Cone beam computed tomography scans were obtained before surgery (T1), immediately after expansion (T2) and six months after expansion (T3). The lateral osteotomy design had no bearing on the maxillomandibular changes after SARME. Both groups showed an increase in maxillary transverse measurements and clockwise rotation with lateral displacement of the mandible immediately after expansion. Maxillary changes showed to be stable six months after SARME, except for nasal floor width and tooth tipping which decreased at T3. Mandibular displacements tended to return close to their initial values at T3. No significant changes in condyle fossa relationship were observed at any time points. The design of lateral osteotomy of the maxilla did not affect the outcomes of SARME, which occurred by tipping of maxillary segments. Clockwise rotation and lateral displacement of the mandible are transient effects of SARME. / Mestre
332

Estudo dacriocistográfico e tomográfico da via lacrimal excretora de cães portadores de epífora /

Vieira, Nívea de Mattos Góes. January 2009 (has links)
Orientador: José Joaquim Titton Ranzani / Banca: Cláudia Valéria Seullner Brandão / Banca: Silvana Artioli Schellini / Resumo: O mecanismo de drenagem lacrimal do cão não é totalmente conhecido. Afecções do sistema nasolacrimal no cão podem ser congênitas ou adquiridas, e são causadas pela ausência de patência ou por processos inflamatórios. A propedêutica da via lacrimal excretora é importante para identificar a causa da epífora. Pelo exame de Radiografia (R-X) e da Tomografia Computadorizada (TC), obtêm-se imagens da trajetória, conformação, tortuosidades e anormalidades do ducto lacrimonasal (DLN). O estudo tomográfico permite análise minuciosa, quando comparada à técnica radiográfica contrastada, que sofre interferência de estruturas ósseas regionais. A principal vantagem da TC sobre outros métodos de diagnóstico por imagem consiste em detectar lesões ósseas. O objetivo deste estudo foi correlacionara presença de epífora em cães de diferentes raça, pelagem, sexo, idade, peso, intensidade da mancha lacrimal e as alterações do ducto lacrimonasal vistas ao exame DCG e com TC, ambos com o uso de contraste iodado. Foram utilizados 20 cães, de raças e pelagens variadas, machos e fêmeas, com pesos entre 01 e 20 kg, de 0 a 08 anos de idade, todos apresentando epífora crônica. Foram utilizados, como grupo controle, 15 cães, sem alterações clínicas de drenagem, de raças e pelagens variadas, machos e fêmeas, com pesos entre 01 e 20 kg, de 0 a 08 anos. Esses animais também foram submetidos à radiografia, seguida de tomografia computadorizada, ambas sob técnicas contrastadas. Com os resultados obtidos, concluiu-se que: os cães da raça poodle, de pelagem clara e pequeno porte, jovens e adultos jovens, com epífora moderada foram os mais acometidos pela mancha lacrimal; dilatações também podem ser observadas em alguns cães sem sinal clínico da afecção; comunicação do ducto lacrimonasal com o seio nasal não indica alteração causadora de epífora... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The dog's lachrymal drainage mechanism is not completely known. Nasolachrymal system affections on dogs might be congenital or acquired, and are caused by patency absence or inflammatory processes. Workup of the lacrimal drainage system is important to identify the cause of epiphora. By radiography exams (x-ray) and computed tomography (CT scan) is possible to obtain trajectory, conformation, sinuosities and naso-lachrymal duct anomalies images. The tomographic study allows a careful analysis, when compared to the contrasted radiography technique, which suffers interference from regional bone structures. The CT scan main advantage over other image diagnosis methods consists in detecting bone lesions. This study objective was to correlate epiphora presence in animals of different breed, coating, sex, age, weight intensity of staining and naso-lachrymal ducts alterations in dogs presenting epiphora, views through of DCG examination and CT scan techniques, both using iodized contrast. Twenty dogs were used, different breeds and coatings, male and females, weighing from 1kg to 20kg, ages varying from newborn to 8 years old, all of them presenting epiphora. Were used as a control group, fifteen dogs with no clinical alterations in nasolachrymal duct drainage, from different breeds and coatings, males and females, weighing from 1kg to 20 kg, ages varying from newborn to 8 years old. These animals were also submitted to radiography, followed by a CT scan, both under contrasted techniques. With the obtained results, it was possible to conclude that: the poodles dogs, clear coating and small size, youth and young adults, and with moderate epiphora were the most affected by the tear stains; dilations can be observed in some dogs without clinical signs of disease; nasolacrimal duct communication with the sinus does not indicate change causing epiphora, because it is present in animals... (Complete abstract click electronic access below) / Mestre
333

Correlação entre imagens de tomografia computadorizada e cortes anatômicos do encéfalo de cães /

Páfaro, Vanessa. January 2012 (has links)
Orientador: Júlio Carlos Canola / Banca: Fabrício Singaretti de Oliveira / Banca: Gustavo Garkalns de Souza Oliveira / Banca: Bruno Watanabe Minto / Banca: Márcia Rita Fernandes Machado / Resumo: Visto a crescente importância das afecções neurológicas na clínica médica veterinária e a escassez de informações em relação aos aspectos tomográficos normais da anatomia encefálica, este estudo objetivou estabelecer a descrição anatômica detalhada de imagens tomográficas do encéfalo normal de cães, utilizando como referências imagens anatômicas de cortes transversais corados, com espessuras semelhantes aos planos das imagens da tomografia computadorizada. Para tanto foram realizados exames de tomografia computadorizada com e sem contraste, de cinco fêmeas caninas, sem raça definida, adultas, com peso variando entre 10 a 12 kg, com cortes transversais encefálicos na espessura de cinco milímetros. Uma fêmea canina, após o exame de TC, foi submetida à eutanásia por indicação clínica e uma solução de formaldeído 3,5% foi injetada pelo átrio direito até ocorrer perfusão do encéfalo. O mesmo foi seccionado em planos transversais semelhantes aos da tomografia computadorizada e corados pela técnica de Barnard, Robert e Brown, que cora substância cinzenta em azul, realçando o contraste entre a substância cinzenta e branca. A descrição das estruturas anatômicas visibilizadas servirá como guia aos médicos veterinários, uma vez que permitirá transcrever com precisão mais fidedigna a região encefálica de um cão acometido por uma lesão, outrossim, correlacioná-la com a sintomatologia clínica do paciente em análise / Abstract: Due to the growing importance in neurological disorders in veterinary medicine and the scarcity of information regarding the normal tomography anatomy of the brain, this study aimed to establish a detailed anatomical description of tomography images of normal brain of dogs, using as reference anatomical images of transverse sections stained with thicknesses similar to the plans of the CT images. Therefore, we performed CT scans with and without contrast, five female dogs, mongrel, adult, weighing to 10 to12 kg, with cross-sectional brain injury in the thickness of five millimeters. A 3,5% formaldehyde solution was injected through the right atrium to the perfusion of the brain occurs in a female dog that was euthanatized due to clinical indication. The brain was sectioned in transverse planes similar to those of CT and stained with Barnard, Robert and Brown, which stains gray blue highlighting the contrast between the gray and white matter. The description of the anatomical structures visualized will serve as a guide for veterinarians, as it will enable more reliable transcribe accurately the region of a dog brain affected by injury, moreover, correlate it with clinical symptoms of the patient in analysis / Doutor
334

Influência de diferentes técnicas de instrumentação no travamento e adaptação de cones de guta-percha .O4 analisados por tomografia computadorizada /

Vasconcelos, Rafaela Andrade de. January 2012 (has links)
Orientador: Simone Helena Gonçalves de Oliveira / Banca: Ana Paula Martins Gomes / Banca: Norberti Bernardineli / Resumo: O objetivo deste estudo foi avaliar a influência de diferentes técnicas de instrumentação no travamento e adaptação do cone de guta-percha .04 em canais radiculares. A avaliação foi realizada observando o local onde o cone entrava em contato com o maior número de paredes internas do canal radicular através da tomografia computadorizada de feixe cônico (TCFC). Foram utilizados 105 dentes humanos unirradiculados, divididos em 7 grupos de instrumentação (n=15): híbrida oscilatório + Manual (OM); Manual (M); Protaper Universal (P); híbrida oscilatório + Protaper (OP); Mtwo (MT); híbrida oscilatório + Mtwo (OMT); Reciproc (R). Finalizadas as instrumentações, o travamento do cone .04 foi realizado 1mm aquém do ápice sendo conferido com uma radiografia digital. As imagens tomográficas foram adquiridas através do TCFC ICat e realizadas nos cortes frontal, sagital e transversal através do software Xoran. Os dados foram submetidos à análise estatística de comparação das proporções via teste "Z" da curva normal, teste Exato de Fisher e quando necessário teste Qui-quadrado. Os resultados apresentaram 100% de travamento do cone no terço apical em todas as instrumentações. A adaptação do cone nas quatro paredes do canal apresentou uma variação de 26,67% (OMT e P) a 73,33% (MT) havendo diferença estatística entre esses grupos (pvalor = 0,027 < 0,05). Em todos os tipos de instrumentação as paredes que apresentaram menor contato foram as vestibulares e as linguais. Os valores médios de área sem contato do cone variaram de 0,06mm2 (MT) a 0,41mm2 (OMT). Concluiu-se que as técnicas de instrumentação podem influenciar no travamento do cone quanto ao número de paredes contactadas ao canal, e também, ao valor de área em que o cone não se adapta ao canal, e não influenciam no nível de travamento do cone / Abstract: The aim of this study was to assess the influence of different instrumentation techniques on the adaptation of .04 gutta-percha points into root canals. The assessment was performed at areas of greater contact of gutta-percha to root canal walls, by means of cone-beam computed tomography. One hundred and five uniradicular human teeth were used. Teeth were divided into 7 groups according to instrumentation (n=15) technique: hybrid oscillatory+Manual (OM); Manual (M); Protaper Universal (P); hybrid oscillatory+Protaper (OP); Mtwo (MT); hybrid oscilatory+Mtwo (OMT); Reciproc (R). Gutta-percha point was adapted 1mm from apex and confirmed by digital radiography. Tomographic images were obtained through CFCT Icat (imaging Science International, USA) and analyzed at the frontal, sagittal and transversal planes by means of Xoran software (Xoran Technologies, USA). Data were submitted to statistical Z test for normal distribution, Exact Fisher test, and Chi-square when necessary. Results: One hundred percent of points were adapted at the apical third of the roots for every instrumentation procedures. The adaptation of points at the four canal walls varied from 26.67% (OMT and P) to 73.33% (MT), with statistical differences among the groups (p = 0,027). The buccal and lingual walls presented the lowest contact of point for all instrumentation procedures. The mean average wall areas without contact varied from 0.06mm2 to 0.41mm2(OMT). It was concluded that different instrumentation techniques might influence the adaptation of gutta-percha points in relation to the number of walls contacted, as well as in relation to the wall area not adapted to the guttapercha point, and no influence in adaptation level / Mestre
335

Estudo comparativo do índice cortical medular do tecido ósseo humano por meio dos níveis de cinza de tomografias convencionais e computadorizadas /

Oliveira, Myrna Lícia Gelle de. January 2006 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Claudio Costa / Banca: Edmundo Medici Filho / Resumo: A proposta dessa pesquisa foi estabelecer índices do tecido ósseo humano obtidos a partir da razão entre os valores dos níveis de cinza do tecido ósseo da base pelo tecido ósseo esponjoso da mandíbula, bem como realizar o estudo da maxila por meio do razão entre a cortical óssea da fossa nasal pelo tecido ósseo esponjoso para as mesmas regiões e avaliar sua variação em função da localização anatômica e o tipo de tomógrafo utilizado (OP100-Instrumentarium®, Scanora® e Newtom3G). A amostra foi constituída de 126 cortes tomográficos convencionais e computadorizados de pacientes que foram subdivididos em 63 cortes para a mandíbula e 63 para a maxila. A análise estatística dos dados para verificação do erro do método não foi significante, validando a metodologia proposta e atestando sua reprodutibilidade; o teste de análise de variância ANOVA de 2 fatores verificou que só houve diferenças estatísticamente significantes entre os índices cortical/medular (Ic/m) da mandíbula e maxila, sendo que não houve diferenças sgnificativas dos índices para os tomógrafos. Concluímos que o índice proposto não apresenta variações quanto à natureza do exame radiográfico em que foi mensurada a densidade óssea e que o mesmo varia de acordo com sua ocorrência (mandíbula> Ic/m>maxila). / Abstract: The aim of this research was calculate indices of bone human tissue from the ledger of gray scale values by basis cortical tissue and medular tissue of the mandible, as well as, establish a study of the maxilla from the ledge between cortical tissue of nasal cavity and medular tissue for the same regions, assessment anatomical region and differents tomographs (OP100- Instrumentarium®, Scanora® e Newtom3G). The sample consisted in 126 conventional and computerized tomographics image, 63 of the mandible and 63 of the maxilla. The statistical analysis have not showed significant differences from the method, so it is reproductible for the same examiner; ANOVA(variancy analyses )demonstrated statistically significant differences between the indices of mandible and maxilla,but, have not demonstrated statistically significant differences between the tomographs indices. In conclusion, the proposal indice don’t show variations related with the kind of tomographs what it was measured the osseous density and it changes in agreement with the circumstance of the mandible and maxilla / Mestre
336

Tomografia por biosusceptometria de corrente alternada /

Fonseca Filho, Paulo Roberto da. January 2014 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Oswaldo Baffa Filho / Banca: Roberto Morato Fernandez / Banca: Fernando Gomes Romeiro / Banca: Valmir Fadel / Resumo: A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / Abstract: The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research / Doutor
337

Estudo da precisão da análise de tomografias espirais de mandíbulas humanas secas realizadas pelo tomógrafo X-Mind Tome /

Munhoz, Felipe Camargo. January 2008 (has links)
Orientador: Gilberto Aparecido Coclete / Banca: Alvimar Lima de Castro / Banca: Cleverson Luciano Trento / Resumo: O sucesso dos implantes dentários depende de um cuidadoso planejamento préoperatório. O exame radiográfico é de fundamental importância na avaliação da morfologia, inclinação óssea e localização de estruturas anatômicas críticas durante os procedimentos de implantação, quando é necessário medir a quantidade de osso disponível. A Tomografia convencional é um exame de extrema importância, pois permite a mensuração da altura e espessura do rebordo alveolar, determinantes na escolha do tamanho do implante. Poucos autores estudaram a influência da variação do movimento tomográfico na qualidade da imagem. O objetivo deste trabalho foi elucidar precisamente as áreas avaliadas pelas imagens fornecidas por tomografias realizadas pelo tomógrafo espiral X-MIND TOME, fabricado em 2005 pela SOREDEX, Helsink, Finlândia. Foram utilizadas dez mandíbulas humanas secas, desdentadas na região dos pré-molares e molares. Os implantes foram posicionados bilateralmente em oito mandíbulas e unilateralmente em duas, com a distância de 4 mm um do outro. Em seguida, cada mandíbula foi adaptada ao tomógrafo, onde foi realizada uma radiografia panorâmica prévia, com magnificação de 50%. Sobre esta radiografia foi colocado um template que determina a região a ser avaliada, sendo realizados cortes de 4mm de largura, nos dois lados da mandíbula. Comparou-se então a solicitação ao tomógrafo com os resultados obtidos, quanto à distância e a ordem dos cortes solicitados. Foram realizadas 19 tomografias que foram avaliadas utilizando-se o programa Radioimp RADIO MEMORY - Belo Horizonte - Brasil. Em seguida, os dados foram tabulados, analisados e estudados estatisticamente, com nível de significância 5%. Através do teste de Wilcoxon, não foram evidenciadas diferenças estatisticamente significantes nos dados obtidos pelas tomografias, sendo, portanto, precisas. / Abstract: The success of dental implants depends on a carefull pre-opertative planning. The radiographic exam is of main importance for a correct evaluation of morphology, bone inclination and location of critical anatomical structures during the surgical procedures for dental implants, when it's necessary to measure the amount of available bone. The conventional Tomography is a very important exam, because it allows the measurement of height and thickness of the alveolar bone for the determination of the implant's size. Few authors studied the influence of the tomographic movement variation in the quality of the image. The aim of the present paper is to clarify the precision of the areas evaluated by the images given by the spiral scanning X-MIND TOME, made in 2005 by SOREDEX, Helsink, Finland. There were used 10 dried mandibles, toothless in the region of pre-molars and molars. The implants were placed in both sides in eight mandibles and in one side in two, with the distance of 4mm one from another. After this, each mandible was placed in the scanning, where a previous panoramic radiograph was taken, with magnification of 50%. Upon this radiograph, it was placed a template to determine the region to be evaluated, where there were made cuts of 4mm of width, in both sides of the mandible. The scanning request was then compared to the obtained results. It was made 19 radiographs that were evaluated using the Radioimp program (RADIO MEMORY - Belo Horizonte - Brazil). The data were then analyzed and studied statistically, with significance of 5%. Throught wilcoxon test, there were not noticed statistical differences in the data obtained in the tomographies, that showed to be precise. / Mestre
338

Correlação entre tomografia computadorizada de alta resolução e provas de função pulmonar em lactentes com bronquiolite obliterante pós-infecciosa

Marques, Maurício Barreira January 2006 (has links)
Made available in DSpace on 2013-08-07T19:06:40Z (GMT). No. of bitstreams: 1 000385370-Texto+Completo-0.pdf: 1287077 bytes, checksum: 12a26000be729af4f08639e9d74e11ac (MD5) Previous issue date: 2006 / Purposes: To evaluate the correlation between high-resolution computed tomography (HRCT) findings of brochiolitis obliterans (BO) and pulmonary function testing in infants; predict the function test results from HRCT scores of air-trapping and bronchiectasis; characterize the HRCT alterations of BO. Methods: Twenty HRCT examinations and pulmonary function testing were performed in 18 BO patients. HRCT scores of air-trapping (graded 0-3) and bronchiectasis (graded 0-3) were correlated with FVC, FEF 50%, FEF 75%, FEF 85%, FEF 25-75% and FEV 0,5. Results: There was a good to moderate correlation between air-trapping score and FEF 50% (ρ = -0,50; p = 0,023), FEF 75% (ρ = -0,54; p = 0,014), FEF 85% (ρ = -0,55; p = 0,011), FEF 25-75% (ρ = -0,50; p = 0,026) e VEF 0,5s (ρ = -0,48; p = 0,025). The bronchiectasis score was only correlated with FEF 50% (ρ = -0,50; p = 0,025). Using simple linear regression analysis we could predict the pulmonary function parameters of FEF 50%, FEF 75%, FEF 85% e FEF 25-75%, from air-trapping score. HRCT findings were air-trapping, bronchiectasis, subsegmentar atelectasis, centrilobular nodules, bronchial wall thickening, “tree-in-bud” opacities and segmentar atelectasis. Conclusions: There is a good to moderate correlation between the severity of air trapping at HRCT and pulmonary function in BO infants. The air-trapping score system may be used to predict FEF 50%, FEF 75%, FEF 85% e FEF 25-75%, when pulmonary function testing is not available or cannot be performed. A characteristic pattern of small airways disease was found in our study. / Objetivos: Avaliar a correlação das alterações de bronquiolite obliterante (BO) à tomografia computadorizada de alta resolução (TCAR) e manobras expiratórias forçadas a partir de volumes elevados (MEFVE) em lactentes; predizer os parâmetros de função pulmonar através de escores tomográficos para alçaponamento aéreo expiratório e para bronquiectasias; caracterizar os achados tomográficos presentes nesta população. Métodos: Dezoito pacientes com BO, vinculados à nossa instituição, realizaram um total de 20 exames de TCAR e MEFVE. Estabeleceram-se escores tomográficos para quantificação de alçaponamento aéreo expiratório (0-3) e para bronquiectasias (0-3), correlacionados com os parâmetros de função pulmonar CVF, FEF 50%, FEF 75%, FEF 85%, FEF 25-75% e VEF 0,5s. Resultados: O escore de alçaponamento apresentou correlação inversa, moderada a forte, com os parâmetros FEF 50% (ρ = -0,50; p = 0,023), FEF 75% (ρ = -0,54; p = 0,014), FEF 85% (ρ = -0,55; p = 0,011), FEF 25-75% (ρ = -0,50; p = 0,026) e VEF 0,5s (ρ = -0,48; p = 0,025). O escore de bronquiectasia correlacionou-se apenas com FEF 50% (ρ = -0,50; p = 0,025). Através da regressão linear simples foi possível estabelecer modelos matemáticos para predizer os parâmetros de FEF 50%, FEF 75%, FEF 85% e FEF 25-75%, partindo do escore de alçaponamento aéreo. Os achados tomográficos mais freqüentes foram alçaponamento aéreo, bronquiectasias, atelectasias subsegmentares, nódulos centrolobulares, espessamento de paredes brônquicas, opacidades em “árvore em brotamento” e atelectasias segmentares. Conclusões: Há correlação inversa, forte a moderada, entre o escore de alçaponamento aéreo e os parâmetros de fluxos e volume das MEFVE em lactentes com BO. O escore de alçaponamento pode ser utilizado para estimar os valores dos parâmetros FEF 50%, FEF 75%, FEF 85% e FEF 25-75% da função pulmonar, quando esta não for disponível para avaliação de lactentes. Os achados tomográficos encontrados em nosso estudo revelam padrão típico de doença de pequenas vias aéreas.
339

Análise da exatidão de programas computacionais no planejamento pré-operatório em implantodontia

Britto, Luiz Gustavo Fleck Heck January 2013 (has links)
Made available in DSpace on 2013-12-27T01:01:18Z (GMT). No. of bitstreams: 1 000452968-Texto+Completo-0.pdf: 1779851 bytes, checksum: 6d3d5366238c50a7f73a3e905f25cb70 (MD5) Previous issue date: 2013 / The tomography-based virtual planning systems allow the surgeon to select the best location for the placement of dental implants. Taking the virtual planning from the computer into reality correctly is attached to a great number of factors. The aim of this study was to analyse the precision of linear measurements performed in two different virtual planning softwares, when compared to the linear measurements performed on a real object. Eight human mandible replicas were used in this study. Linear measurements were performed in specific points of this replicas. The same measurements were made using the virtual planning softwares, and then compared to the real object. Statistically significant difference between the groups was found. The Nobelguide software group presented significantly lower values when compared to the real mandibles, while the Dentalslice software group showed significantly higher values, compared to the real measurements. Within the limitations of this in vitro study, the authors conclusion is that further studies are needed to determine the applicability of virtual planning sotwares on the clinical pactice. / Os sistemas de planejamento virtual, baseados em imagens tomográficas, possibilitam ao profissional definir as regiões mais adequadas para a colocação de implantes dentários. Diversos fatores influenciam na transferência do planejamento virtual para o campo cirúrgico. O objetivo desta pesquisa foi avaliar a exatidão de mensurações lineares de dois softwares de planejamento quando comparados a medições lineares realizados em um objeto real. Para isso, utilizaram-se oito réplicas de mandíbulas humanas onde foram realizadas medições em pontos específicos. Estas medições foram realizadas também no âmbito virtual e comparadas com as mensurações realizadas no objeto real. Ao se aplicar o teste estatístico t de Students para comparar as amostras, verificaram-se diferenças estatisticamente significativas. O software Nobelguide® apresentou valores significativamente inferiores aos valores reais enquanto o software Dentalslice® apresentou valores significativamente superiores aos valores encontrados no objeto real. Dentro das limitações deste estudo in vitro, indica-se a necessidade de estudos complementares que verifiquem a aplicabilidade destes softwares de planejamento na prática clínica.
340

Efeitos da expansão rápida da maxila nos tecidos moles

Kochenborger, Claudia January 2014 (has links)
Made available in DSpace on 2014-07-12T02:02:13Z (GMT). No. of bitstreams: 1 000459195-Texto+Completo-0.pdf: 1109615 bytes, checksum: cec9f8817ef7ec230e0ed47f7837f0a9 (MD5) Previous issue date: 2014 / Introduction: To evaluate the effects of rapid maxillary expansion (RME) in the soft tissues of patients with and without cleft lip and palate using cone beam computed tomography (CBCT).Materials and Methods: CBCT were selected from 60 patients with ERM divided into two groups. Group 1: 30 patients without cleft (9 boys and 21 girls; ± 10. 7 years) and Group 2: 30 cases with cleft (18 boys and 12 girls; ± 10. 0 years). CBCT were performed at T1, before the ERM, and T2 after RME. The CBCT images were analyzed in OsiriX MD software (FDA approved, version 1. 4. 2; Pixmeo, Geneva, Switzerland ) according to the following variables: superior nasal width (Mfd - Mfe), nose base width (Cad- Cae), alare width (Ald – Ale), columella width (Nstd- Nste), nose base length (Sn - Prn), right nasal cavity width (Cned- Cnid), left nasal cavity width (Cnee- Cnie), columella length (Sn - Cl), nasolabial angle (ANL).Results: data were evaluated by student's t test and the Mann-Whitney nonparametric test with a significance level of 5%. Significant difference on the soft tissues width of the nose were demostrated for both groups after RME.Conclusion: there was an increase on the soft tissues width of the nose after the RME in both groups and differences were greater in the group without cleft in T2. / Introdução: avaliar os efeitos da expansão rápida da maxila nos tecidos moles de pacientes com e sem fissura lábio-palatina por meio da tomografia computadorizada cone beam (TCCB).Materiais e Métodos: foram selecionados 60 pacientes tratados com a ERM divididos em dois grupos. Grupo 1: 30 pacientes sem fissura (9 meninos e 21 meninas; ±10. 7 anos) e Grupo 2: 30 pacientes com fissura lábio palatal (18 meninos e 12 meninas; ±10. 0 anos). TCCB foram realizadas em T1, antes da ERM e T2, imediatamente após a estabilização do parafuso expansor. As imagens tomográficas foram analisadas no programa OsiriX MD (FDA approved, version 1. 4. 2; Pixmeo, Geneva, Switzerland) de acordo com as seguintes variáveis: largura nasal superior (Mfd- Mfe); largura da base do nariz (Cad- Cae); largura da asa do nariz (Ald- Ale); largura da columela (Nstd- Nste); comprimento da base do nariz (Sn-Prn); largura da cavidade nasal direita (Cned- Cnid); largura da cavidade nasal esquerda (Cnee- Cnie); comprimento da columela (Sn-Cl); ângulo nasolabial (ANL).Resultados: os dados foram avaliados pelo teste t-student e pelo teste não-paramétrico Mann-Whitney com nível de significância de 5%. Ocorreu diferença significativa na largura dos tecidos moles do nariz para ambos os grupos após a ERM.Conclusão: observou-se aumento da largura nos tecidos moles do nariz após a expansão rápida da maxila em ambos os grupos sendo que em T2 as diferenças foram superiores para o grupo sem fissura.

Page generated in 0.4002 seconds