• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 727
  • 11
  • 11
  • 11
  • 11
  • 7
  • 7
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 747
  • 747
  • 292
  • 250
  • 176
  • 119
  • 109
  • 100
  • 85
  • 68
  • 62
  • 58
  • 54
  • 51
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
471

Endurecimento da superfície do aço ferramenta VC131 utilizando laser a fibra.

Flávia Aline Goia 21 December 2010 (has links)
Os tratamentos de superfície têm apresentado grande importância na melhoria das propriedades dos materiais, visando a economia e viabilização de novos métodos e processos de fabricação. O tratamento de refusão e têmpera a laser promove o rápido aquecimento e resfriamento da camada superficial dos metais, resultando em transformações microestruturais que melhoram as propriedades mecânicas sem provocar distorções ou empenamentos. No presente trabalho foi utilizado um laser a fibra de alta potência para produzir uma camada endurecida num aço ferramenta para trabalho a frio VC131. Os parâmetros de refusão estudados foram a velocidade de varredura, a desfocalização do feixe e a potência do laser. A escolha das melhores condições de tratamento para a superfície completa foi feita a partir de ensaios em ponto e linha, analisando os parâmetros onde foi alcançada maior dureza, com pouco material fundido, e sem defeitos. A variação de temperatura foi acompanhada nos ensaios em linha, mostrando que a peça permanece fria com aumento da temperatura nunca ultrapassando 13C. A partir da variação da temperatura foi feito o cálculo da absortividade sendo aproximadamente 37 % nas condições analisadas. Foram feitas análises microestruturais e por difração de raios-X do aço, verificando-se que a microestrutura resultante da superfície temperada apresenta quantidade significativa de martensita e austenita retida, que confere ao material o aumento da dureza. A zona fundida apresentou dureza entre 400 e 500 HV, enquanto um pico de dureza de até 800 HV foi observado na interface da zona fundida e da zona termicamente afetada. A máxima profundidade de têmpera ficou entre 1 e 2 mm, para os ensaios onde toda a superfície foi tratada. Os ensaios tribológicos indicam que a superfície tratada a laser apresenta uma resistência ao desgaste superior àquela observada nas amostras não-tratadas.
472

Avaliação tribológica da aplicação de lubrificantes sólidos com laser de CO2 em atmosfera ambiente em aço AISI 52100.

Anderson Ferreira da Silva 12 August 2010 (has links)
Neste trabalho, são apresentados os resultados da avaliação tribológica da aplicação de lubrificantes sólidos, no caso grafita, sobre a superfície do aço AISI 52100 via laser de CO2. O trabalho surgiu da busca pela melhoria das propriedades superficiais dos materiais que têm solicitações diferenciadas na superfície. A utilização do laser para tratamentos de superfícies, por exemplo, aplicação de lubrificantes sólidos em atmosfera ambiente, tem possibilitado grandes avanços nesta área. No entanto, determinar quais parâmetros operacionais do laser e a resultante destas influências sobre as propriedades tribológicas dos materiais tem sido uma busca incessante. Os resultados deste trabalho confirmam que existe uma faixa de processamento laser eficaz na redução do atrito e do desgaste. Sendo que as energias necessárias variam de 3 a 11 J/m2. Ainda, verifica-se que as amostras tratadas com laser, apresentam um coeficiente de atrito da ordem de 0,3 enquanto, amostras sem tratamento laser o atrito é da ordem e 0,7. As análises químicas por EDX e EDS demonstram uma difusão atômica de curto alcance nas zonas tratadas com o laser.
473

Soldagem com laser a fibra do aço 300M de alta resistência.

Sheila Medeiros de Carvalho 28 May 2009 (has links)
Os aços com plasticidade induzida por deformação, também conhecidos como aços TRIP, são de grande interesse nas indústrias aeroespacial e automobilística por apresentarem uma elevada tenacidade e resistência especifica (resistência mecânica / densidade), o que possibilita que as estruturas sejam cada vez mais leves. O estudo da soldabilidade desses aços tem sido objeto de especial interesse, visto que, ao ser soldado pelos processos convencionais, observa-se uma perda na resistência mecânica e na ductilidade. Neste trabalho, foram realizadas soldas em chapas de 3 mm de espessura do aço AISI 300M previamente normalizado. O processo de soldagem utilizou um laser a fibra de 2 kW, sem metal de adição. Os parâmetros de soldagem estudados são a velocidade de soldagem e a potência do laser. A condição de soldagem em que se verificou o preenchimento total da espessura da chapa foi com velocidade de 50 mm/s e potência de 1200 W. Visando diminuir as perdas nas propriedades mecânicas do material após a soldagem, foi estudado o efeito do tratamento térmico de revenimento sobre o cordão de solda de duas maneiras. Primeiramente, utilizou-se um laser a fibra como fonte de calor para promover o revenimento do material. Notou-se por meio dos dados obtidos da microestrutura, da microdureza e do modelo de simulação de temperaturas, que o laser não permite o tratamento térmico de revenimento em toda espessura do cordão sem fundi-lo. Na segunda maneira estudada para promover o tratamento térmico de revenimento, foi utilizado de um forno elétrico tipo mufla, no qual os CDPs foram mantidos por 2 horas nas temperaturas de 100, 200, 250, 300, 400, 500 e 650 C. Com os resultados obtidos nesse tratamento, é possível observar que: a microdureza do cordão cai continuamente com o aumento da temperatura; que a fragilidade ao revenimento se dá em temperatura próxima a 300 C; e que, a partir de 500 C, tanto os microconstituintes do metal base, quanto do cordão de solda começam a passar por transformações mais próximas à normalização. Como última análise neste trabalho, foram realizados ensaios mecânicos em tração uniaxial para que fossem comparados as propriedades mecânicas dos corpos-de-prova confeccionados no estado como recebido, soldado e soldado com posterior tratamento térmico de revenimento a 200 e 400 C. Concluiu-se que, no caso dos CDPs soldados e revenidos a 200 e 400 C, o limite de escoamento e a tensão de ruptura são praticamente os mesmos do material ensaiado como recebido e que há um ganho de cerca de quatro vezes na ductilidade quando comparado com o material somente soldado.
474

Caracterização pelo método de rietveld da zircônia tetragonal em sistemas ZrO2-SiO2 obtidos por sol-gel

Hiure Anderson Alves da Silva Queiroz 21 December 2011 (has links)
Materiais a base de zircônia (ZrO2) têm sido empregados como cerâmicas estruturais, revestimento para barreiras térmicas, catalisadores, eletrólitos para células a combustível, dispositivos óticos e eletrônicos, etc. A funcionalidade destes materiais é definida por suas propriedades físico-químicas e mecânicas, muitas das quais podem ser controladas pela microestrutura da fase cristalina, sendo a estabilização da fase tetragonal (ZrO2-t, estável acima de 1170C) desejada em muitas destas finalidades. Neste trabalho, compósitos de ZrO2-SiO2 com diferentes composições foram obtidos pelo método sol-gel catalisado por ácido, utilizando acetato de zircônio e tetraetóxissilano como precursores. Os materiais particulados obtidos foram submetidos a tratamentos térmicos entre 1000 e 1550C, com o objetivo de avaliar a estabilização da fase ZrO2-t. O processo sol-gel foi avaliado por FT-IR, fazendo-se o acompanhamento temporal das reações envolvidas, tendo-se verificado que o acetato de zircônio apresenta baixa velocidade de reação se comparado ao alcóxido de silício, o que pode induzir a formação de um gel difásico e justificar a formação de diferentes fases de sílica e/ou zircônia obtidos nas diferentes composições. A caracterização estrutural foi realizada por DRX, indicando a formação de ZrO2-t em todos os sistemas avaliados após tratamento térmico. O refinamento Rietveld possibilitou a análise da evolução desta fase nos diferentes sistemas, tendo-se verificado que para a amostra contendo 18% de zircônia (18ZrO2-82SiO2) houve a estabilização total da fase ZrO2-t. Com o aumento da quantidade de ZrO2 no sistema, observou-se o aumento no tamanho médio de cristalito e a estabilização parcial da fase tetragonal.
475

Resistência mecânica do aço AMS-6414 (ABNT-4340), após desidrogenação em forno convencional, quando protegido com cromo duro e cádmio LHE (low hydrogen embrittlement).

José Carlos Nogueira 00 December 2003 (has links)
A indústria aeronáutica utiliza dezenas de ligas metálicas na fabricação de aeronaves e seus equipamentos, que necessitam estreitos e restritos padrões de segurança e confiabilidade, onde se incluem os da fragilização pelo hidrogênio. O presente trabalho avalia a resistência mecânica do aço AMS 6414 (ABNT - 4340), largamente utilizado na fabricação de trens de aterrissagem. Os corpos-de-prova são confeccionados segundo as normas ASTM-E-8 e ASTM F-519, sendo 50% com entalhe e 50% seu entalhe.O material é tratado para uma dureza de 50,5 a 53,0 HRC (alta resistência). Após tratamento térmico, é submetido à aplicação de cromo duro convencional e cádmio LHE ("Low Hydrogen Embrittlement"), desidrogenação em forno convencional.São levantadas as curvas de resistência à ruptura do aço, utilizando-se tempos de desidrogenação de 8, 12, 16, 19 e 23 horas, à temperatura de 190 5C (devido ao fato de ser a temperatura mais utilizada para este processo na indústria aeronáutica). Os resultados obtidos apontam para perda de resistência mecânica pela possível fragilização pelo hidrogênio, mas também por fadiga térmica do material em determinados intervalos de tempo e temperatura, para o processo de cromo duro.O processo de cádmio LHE apresenta perda de resistência mecânica somente por fragilização provocada pelo hidrogênio. Analisando-se os resultados deste trabalho com os obtidos da literatura (com dureza mais baixa e em ensaio de fadiga por flexão rotativa), conclui-se que os ciclos de produção podem ser reduzidos, mantendo-se o mesmo grau de confiabilidade praticado atualmente.
476

Relações entre termoterapia, germinação, vigor e sanidade de sementes de tomate / Relationship between thermotherapy, germination, vigor and health of tomato seeds

Braga, Marcia Provinzano 19 August 2009 (has links)
O presente trabalho objetivou estudar a relação da termoterapia com o potencial fisiológico e sanidade de sementes de tomate, imediatamente após o tratamento e durante o armazenamento, identificando combinações eficientes de temperatura e período de exposição através do teste de sanidade e testes de vigor. O trabalho, dividido em dois experimentos diferenciados pelos tratamentos e métodos de secagem, foi realizado nos laboratórios de Análise de Sementes do Departamento de Produção Vegetal e Patologia de Sementes do Departamento de Fitopatologia da USP-ESALQ e no Centro de Pesquisa Mokiti Okada M.O.A. No experimento I, sementes de dois lotes dos cultivares de tomate UC-82 e Rio Grande foram submetidas à termoterapia úmida com diferentes combinações de tempo e temperatura (52, 53, 54, 55 e 60°C/30 e 60 min), além das testemunhas (sementes tratadas com fungicida e não tratadas) e secadas ao ar livre por 72 horas. Após o tratamento as sementes tiveram seus desempenhos e sanidades avaliados em duas épocas, após a secagem e após 90 dias de armazenamento, através dos testes de porcentagem e primeira contagem de germinação, velocidade e porcentagem de emergência de plântulas, lixiviação de potássio, envelhecimento acelerado e sanidade. No experimento II, as sementes dos mesmos lotes foram submetidas à termoterapia nas combinações de tempo e temperatura de 55°C/30 min e 60°C/60 min, além das testemunhas, sementes tratadas com fungicida e não tratadas. Após o tratamento, as sementes foram cobertas com papel toalha e secadas por 12 horas e, em seguida, avaliadas através dos testes de sanidade, porcentagem e primeira contagem de germinação e envelhecimento acelerado. Os resultados permitiram concluir que a termoterapia (água quente a 55°C/30 min) é uma opção consistente para o controle de fungos associados às sementes de tomate, sem prejudicar o potencial fisiológico das sementes, dependendo da qualidade inicial do lote; os tratamentos 52 a 54°C por 30 ou 60 min não causam prejuízo ao potencial fisiológico de sementes de tomate, enquanto o efeito do tratamento a 55°C/60 min está associado à qualidade inicial do lote; o tratamento com água quente a 60°C por 30 ou 60 min não constitui opção para o tratamento de sementes de tomate, pois é eficiente para o controle de fungos, mas é letal às sementes; os tratamentos com água quente variando de 52 a 55°C por 30 ou 60 min não são eficientes em eliminar a bactéria Clavibacter michiganensis subsp. michiganensis e acarretam queda da resistência de sementes de tomate, tornando-as vulneráveis à manifestação dos sintomas de cancro bacteriano na plântula; o período de 90 dias de armazenamento em condições controladas (20°C e umidade relativa do ar de 50%) pode reduzir o potencial fisiológico de sementes de tomate tratadas com água quente, mas há necessidade de estudos adicionais com períodos maiores de armazenamento para obtenção de resultados mais consistentes; a termoterapia com água quente deixa as sementes de tomate vulneráveis à contaminação por fungos saprófitos, havendo necessidade de estudos adicionais para determinação de opções de tratamentos complementares que ofereçam efeito residual para evitar futuras contaminações, no armazenamento ou no substrato. / The research had as objective to investigate the relationship between thermotherapy and physiological potential and health of tomato seeds immediately after the treatment and during the storage period, then to identify efficient combinations between temperature and exposure time, through seed health test and seed vigor tests. The research was carried out at the Seed Analysis Laboratory of the Department of Vegetal Production and Seed Pathology Laboratory of Phytopathology Department of USP-ESALQ and at Mokichi Okada Research Center M.O.A.. and was divided in two experiments with different treatment and drying methods. In experiment I, seeds from two lots of UC-82 and Rio Grande tomato cultivars were submitted to humid thermotherapy with different combinations of time and temperature (52,53,54,55 and 60ºC/30 and 60 min.), besides the control treatment (seeds with fungicide treatment and without treatment) and dried at air during 72 hours. After the treatment, seeds were evaluated on their performances and seed health in two different periods (after drying and after 90 days storage), through percentage and first count of germination tests, speed and percentage of seedling emergence, potassium leachate, accelerated aging and seed health test. In experiment II, seeds from the same lots were submitted to thermotherapy under two combination of time and temperature (55ºC/30min and 60ºC/60min), besides the control treatment (seeds with fungicide treatment and without treatment). After treatment, seeds were covered with paper towel and dried during 12 hours, and then evaluated through seed health test, percentage and first count of germination tests and accelerated aging. The results lead to the conclusion that thermotherapy (hot water at 55ºC/30min) is a consistent option to control tomato seedborne fungi, without damaging the physiological potential of the seeds, depending on the initial quality of the seeds lots. Treatments with hot water at 52 to 54ºC during 30 to 60 min do not cause damage to tomato seeds physiological potential, while 55ºC/60 min treatment results are associated with the initial quality of the lots. The treatment with hot water at 60ºC during 30 or 60 min cannot be considered as an option because is very effective to control fungi, otherwise is lethal to the seeds. The treatments with hot water temperature between 52 and 55ºC during 30 or 60 minutes were not effective to eradicate Clavibacter michiganensis subsp. michiganensis and caused the fall of the tomato seed resistance to diseases, turning the seeds vulnerable to bacterial canker symptoms show up in the seedling. Ninety days storage period under controlled conditions (20ºC and relative humidity of 50%) may reduce physiological potential of the hot water treated seeds, but further investigation is needed with longer periods of storage to obtain more consistent results. Thermotherapy with hot water make the tomato seeds more vulnerable to saprophytic fungi contamination, needing additional studies to define the options of complementary treatments that offer residual effect to avoid future contaminations, during storage and in the substrate.
477

Avaliação da influência de aplicação de vibração mecânica na microestrutura e em características mecânicas de juntas do aço inoxidável martensítico CA6NM soldadas pelo processo FCAW / Evaluation of mechanical vibration application on microstructure and mechanical properties of martensitic stainless steel CA6NM welded by FCAW process

Almeida, Luiz Fernando Cursino Briet de 11 December 2015 (has links)
O aço inoxidável martensítico ASTM A743 CA6NM é utilizado para produzir componentes especiais para turbinas hidráulicas, devido às suas boas propriedades mecânicas combinadas com alta resistência à corrosão e cavitação e uma boa soldabilidade. As turbinas hidráulicas são produzidas por meio de múltiplos passes de solda em peças espessas obtidas por fundição. Durante a operação, estes componentes estão sujeitos à erosão por cavitação e trincas em regiões tensionadas, que são reparados também por meio de soldagem. Após o processo de soldagem, um tratamento térmico pós-soldagem é comumente utilizado para aliviar as tensões residuais. Porém, existem dificuldades significativas para a realização de tratamento térmico nas turbinas hidráulicas, tais como a complexidade da geometria de solda, a possibilidade de distorção no caso de quaisquer cargas mecânicas, dificuldade em aquecer simetricamente, e também o tratamento térmico pode causar degradação das propriedades do material. Assim, existe um grande interesse no desenvolvimento de procedimentos de soldagem que elevem a tenacidade ao impacto e evitem o tratamento térmico pós-soldagem. Neste trabalho, a aplicação de vibrações mecânicas durante e após a soldagem para aliviar tensões residuais foram avaliadas em juntas de aço inoxidável martensítico CA6NM soldadas pelo processo Flux Cored Arc Welding (FCAW). A utilização de vibrações mecânicas para reduzir e redistribuir as tensões residuais das estruturas soldadas através da aplicação de carga vibratória pode gerar muitos benefícios. Testes de impacto Charpy (-20 °C), ensaios de tração e dobramento foram realizados conforme ASME IX, e perfis de microdureza nas diferentes regiões da solda foram conduzidos para a caracterização mecânica das juntas soldadas. A caracterização microestrutural foi realizada utilizando difração de raios X, microscopia óptica e microscopia eletrônica de varredura (MEV). Os resultados de propriedades mecânicas das amostras vibradas atenderam as exigências especificadas por norma, na qual o processo com tratamento térmico é recomendado para a soldagem deste tipo de aço, visando atingir os níveis de tenacidade do material original. Com relação à microestrutura não foram observados alterações significativas para as amostras vibradas em comparação com a condição \"como soldado\", porém para a condição com tratamento térmico pós-soldagem foi observado uma pequena quantidade de austenita retida, que são precipitadas após o tratamento térmico e permanecem finamente distribuídas após o resfriamento e auxiliam no ganho de tenacidade das juntas soldadas. / The martensitic stainless steel ASTM A743 CA6NM is used to produce special parts for hydraulic turbines, due to its good mechanical properties combined with high resistance to corrosion and cavitation and good weldability. These components are produced by multiple weld passes in thick parts obtained by casting. During operation, these components are subject to cavitation erosion and cracks in stressed regions, which are also fixed by welding. After the welding process, a post-weld heat treatment (PWHT) is commonly used to relieve the residual stresses. However, there are significant difficulties to perform heat treatment in hydraulic turbines, such as the complexity of the weld geometry, the possibility of distortion in the case of any mechanical loads, difficulty in heat symmetrically, and also heat treatment may cause degradation of the properties of material. Thus, there is great interest in the development of welding procedures that will increase the toughness and avoid post-weld heat treatment. In this work, the application of mechanical vibrations during and after welding to relieve residual stresses were evaluated in martensitic CA6NM stainless steel joints welded by Flux Cored Arc Welding (FCAW). The use of mechanical vibration to reduce and redistribute the residual stresses of welded structures through the vibration loading application can generate many benefits. Charpy impact test (-20 ° C), tensile and bending tests were performed according to ASME IX, and microhardness profiles in different regions of the weld were conducted to evaluate the mechanical properties of the welded joints. Microstructural characterization was performed using X-ray diffraction, optical microscopy and scanning electron microscopy (SEM). The results of mechanical properties of vibrated samples met the requirements specified by standard, wherein the PWHT is recommended to weld this type of steel, in order to meet original base metal toughness. Regarding the microstructure were not observed significant changes to the vibrated sample compared to the condition as welded, but for the condition with PWHT was observed a small amount of retained austenite, which are precipitated after heat treatment and remain finely distributed after cooling and promote a better toughness of welded joints.
478

BIOCOMPATIBILIDADE DE UMA RESINA ACRÍLICA E REEMBASADORES RÍGIDOS: ANÁLISE HISTOMORFOMÉTRICA EM RATOS

Meister, Lissandra Matos Brol 13 December 2012 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-09-13T19:09:49Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Lissandra Meister.pdf: 2025390 bytes, checksum: 3d7014c9fd4e95c534d20284510966e2 (MD5) / Made available in DSpace on 2018-09-13T19:09:49Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Lissandra Meister.pdf: 2025390 bytes, checksum: 3d7014c9fd4e95c534d20284510966e2 (MD5) Previous issue date: 2012-12-13 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / A ocorrência de reações adversas na mucosa provocadas pelo uso de próteses removíveis é comum. Esse fato tem despertado o interesse por este tópico e muitos estudos tem sido realizados para determinar o comportamento biológico desses materiais objetivando buscar materiais mais biocompatíveis com o meio bucal. Além disso, novas técnicas e tratamentos pós-polimerização de resinas de base e reembasadores são propostos para minimizar a quantidade de produtos liberados e os efeitos que provocam no epitélio bucal. Assim, a proposta do presente estudo foi avaliar a biocompatibilidade de uma resina acrílica e de reembasadores rígidos, em uma análise histomorfométrica em ratos. A hipótese de que um tratamento térmico pós polimerização poderia diminuir a citotoxicidade dessas resinas acrílicas foi avaliada. Para isso, foram utilizados 45 ratos fêmeas adultas (Rattus Norvergicus albinus Wistar), com 60 dias de idade, pesando de 150 g a 250 g, obtidos do Biotério Central da Universidade Estadual de Ponta Grossa. Este estudo foi aprovado e está de acordo com as recomendações do Comitê de Ética em Experimentação Animal (SCEEA-UEPG) e as normas de manipulação de animais do COBEA (Colégio Brasileiro de Experimentação Animal) foram seguidas durante todo o experimento. Placas palatais de resina acrílica termopolimerizável Lucitone 550 foram confeccionadas individualmente, e reembasadas com os reembasadores rígidos Tokuyama Rebase II, New Truliner e Kooliner. Para comparação dos dados, cinco animais que não receberam as placas foram mantidos sob as mesmas condições, durante o experimento (controle). As placas compreendiam a área do palato localizada na região entre os molares, cobrindo as faces oclusal e vestibular dos mesmos e estendendo-se anteriormente até a primeira prega palatina. Metade das placas com reembasadores recebeu tratamento térmico pós-polimerização de imersão em água a 55oC por 10 min e metade das placas confeccionadas apenas com a resina de base receberam o mesmo tratamento térmico, porém pelo tempo de 60 min. As placas foram cimentadas aos molares, com resina fotopolimerizável, permanecendo por 14 dias. Os animais receberam dieta pastosa e água ad libitum. Foi realizada aferição do peso dos animais antes e após o período experimental, em balança de semi precisão. Os animais de todos os grupos foram sacrificados por eutanásia após 14 dias. O palato dos animais foi dissecado, fixado em formol tamponado a 10% durante 48 h e descalcificado em EDTA a 4,17% por aproximadamente quatro meses. As peças assim obtidas foram incluídas em parafina, de forma que a parte posterior do palato ficasse para baixo. As amostras foram cortadas em micrótomo em secções de 5 μm e coradas com hematoxilina e eosina (H&E). Foram realizadas cinco lâminas de cada animal, contendo cinco cortes histológicos. Foram feitas duas imagens, padronizadas da região central dos cortes, em aumento de 200x, para verificar as alterações histológicas. Foram calculadas espessuras de epitélio total, compartimento celular e camada de queratina. A análise estatística aplicada aos dados do peso (g) dos animais nos tempos 0 e 14 dias de utilização das placas foi ANOVA (α = 0,05). Não houve diferença significativa na alteração do peso dos animais. Para comparação dos dados obtidos na análise histológica de todos os grupos analisados foi realizado teste ANOVA de um fator de variação (tipo de placa que o animal recebeu). Em um dos estudos, o grupo sem placa (controle) foi comparado estatisticamente com palatos que receberam placas de resina termopolimerizável submetidas ou não a tratamento térmico. Em outro estudo, o grupo controle foi comparado estatisticamente com palatos que receberam placas reembasadas com os reembasadores submetidos ou não ao tratamento térmico. As médias dos grupos foram comparadas com Pós-teste de Tukey, com α = 0,05. Os resultados da espessura de camada de queratina dos materiais New Truliner, Tokuyama Rebase II e Kooliner sem tratamento térmico adicional foi estatisticamente menor do que a do grupo controle (p<0,0001). Para esse mesmo parâmetro, o tratamento térmico alterou significativamente a média da resina de base Lucitone 550, reduzindo-a. As médias de espessura de tecido conjuntivo das resinas Lucitone 550 e Tokuyama Rebase II sem tratamento térmico adicional foram estatisticamente maiores do que o controle (p<0,01). As mesmas médias de Kooliner, sem tratamento térmico, foram menores do que o controle (p<0,01). O tratamento térmico foi capaz de alterar o comportamento das resinas Lucitone 550, Tokuyama Rebase II e New Truliner, reduzindo significativamente a espessura de tecido conjuntivo dos dois primeiros materiais e aumentando a do último material (p<0,01). As médias de espessura total de epitélio das resinas Kooliner e New Truliner sem tratamento térmico foram significativamente menores do que o controle (p<0,001 e p<0,01, respectivamente). Com relação ao tratamento térmico, esse foi responsável por alterar o comportamento dos materiais Lucitone 550 e Kooliner, aumentando, nos dois casos, a espessura desse tecido (p<0,05 e p<0,001, respectivamente). Com base nos resultados, pôde-se concluir que a utilização de impressões individuais em ratos Wistar, associadas a placas com cobertura oclusal sobre molares e o método de cimentação com resina composta sem o uso de sistema adesivo, proporcionaram boa estabilidade do dispositivo palatino desenvolvido neste estudo e a sua permanência na cavidade bucal dos animais não alterou os hábitos alimentares. Além disso, o tratamento térmico pós-polimerização proposto alterou a biocompatibilidade dos materiais avaliados, dentro das condições experimentais do presente estudo. / The occurrence of adverse reactions in the mucosa caused by the use of removable dentures is very common. This fact raised an interest in this particular matter, and, because of that, a lot of studies have been done in order to determine the biological behavior of these materials, looking for materials that are biocompatible with the oral environment. Besides that, new techniques and treatments after-polymerization of denture base and reline resins are proposed in order to minimize the amount of released products and their effects in oral epithelium. Thus, the purpose of the current study was to test the biocompatibility of an acrylic base and hard chair-side reline resins, with an histopathological analysis in rats. The hypothesis that post-polymerization heat-treatments could reduce the cytotoxicity of these acrylic resins was evaluated. For this purpose, forty five adult female rats (Rattus Norvergicus Albinus Wistar), with 60 days old, weighing 150 g – 250 g, taken from the Biotério Central da Universidade Estadual de Ponta Grossa were used. This study received approval and is in accordance with the Comitê de Ética em Experimentação Animal (SCEEA-UEPG) recommendations, and, the animal manipulation rules of COBEA (Colégio Brasileiro de Experimentação Animal) were followed during the experiment. Palatal plates of heat-polymerized denture base acrylic resin Lucitone 550 (L) were custom-made and relined with Tokuyama Rebase II (TR), New Truliner (NT) or Kooliner (K) hard chair-side reline resins. For data comparison, five animals that did not receive the palates were kept under the same conditions during the experiment (control group). The plates embraced the palate area, in the region between the molars covering the occlusal and vestibular surfaces, being extended up to the first palatal fold. Half of the relined plates received a post-polymerization heat-treatment (immersion in water at 55°C for 10 min) and half of the acrylic resin denture bases received a similar post-polymerization heat-treatment, but for 60 min. The plates were cemented in the molar region with light-cured resin, thus being kept there for 14 days. The animals received a paste diet and water and libitum. Before and after the trial period, the rats were weighed individually on a precision scale. After 14 days, the animals of all groups were sacrificed by euthanasia. The palate of the animals were dissected, fixed in 10% buffered formalin for 48 h and decalcified in 4,17% EDTA for approximately four months. Then, the pieces were processed through a dehydration process to be embedded in paraffin, so that the back part of the palate lied down. The samples were cut with a microtome in sections of 5 μm and then stained with haematoxylin and eosin (H&E). Five histological cuts were done in each animal. Two standardized images from the central region of the cuts were made, referring to the rafe palatine, augmented 200x in order to verify histological changes. These include the thickness calculation of cellular compartment (TCC), total epithelial thickness (TET), and of keratin layer (TKC). Statistical analysis was performed using ANOVA (α = 0.05) test for comparison of weigh (g) of the animals at times 0 and 14 days of device using. There was no significant difference in weight change observed in the animals. For histological data comparisons from all groups it was performed one-way ANOVA (for type of palatal plate used). In one of the studies, the control group (without plates) was statistically compared to acrylic resin denture base plates submitted or not to the post-polymerization heat-treatment. In another study, the control group was statistically compared to palates fitted with relined plates submitted or not to the post-polymerization heat-treatment. Mean values from groups were compared with post-hoc Tukey with α = 0.05. Results from Keratin layer thickness from materials New Truliner, Tokuyama Rebase II and Kooliner without post-polymerization heat-treatment were statistically lower than control group (p<0.0001). For the same parameter, the heat-treatment significantly changed the results from Lucitone 550, reducing it. Means of connective tissue from resins Lucitone 550 and Tokuyama Rebase II whithout treatment were statisticaally higher than the control (p<0.01). The same means from Kooliner, without heat-treatment, were lower than the control (p<0.01). The heat-treatment was able to change the behaviour of resins Lucitone 550, Tokuyama Rebase II and New Truliner, reducing significantly the connective tissue thickness from both the former and augmenting that from the last material (p<0.01). Means of total epithelial thickness from resins Kooliner and New Truliner without heat-treatment were significantly lowers than the control (p<0.001 and p<0.01, respectivelly). As regards to the heat-treatment, it was responsable for change the behavior from materiais Lucitone 550 and Kooliner, augmented, in both cases, the thickness of this tissue (p<0.05 e p<0.001, respectivelly). Based on the results, it was possible to conclude that the use of individual impressions in Wistar rats, associated to plates with occlusal coverage on molars and the cementation with resin method developed in this study did not change their eating habits. Besides that, the post-polymerization heat-treatment proposed changed the biocompatibility of the materials evaluated, under the experimental conditions of this study.
479

Tratamento térmico mínimo do suco de laranja natural: estudo da viabilidade de armazenamento em latas de alumínio. / Fresh single-strength orange juice minimal heat treatment: storage viability in aluminium cans

Shigeoka, Denise Sayuri 24 June 1999 (has links)
No presente projeto, foi estudada a viabilidade do uso da lata de alumínio como embalagem para suco de laranja natural submetido a tratamento térmico mínimo, através de ensaios de vida de prateleira durante um período de 57 dias, com armazenamento em geladeira. O suco foi processado em trocador de calor tipo placas às temperaturas nominais de pasteurização de 80ºC e 85ºC e embalado à temperatura ambiente sob atmosfera de nitrogênio em latas de alumínio revestidas com verniz protetor. As análises foram efetuadas na freqüência de 14 dias (1º, 15º, 29º, 43º e 57º dia após o processamento). As respostas analisadas foram pH, ºBrix, acidez titulável, “ratio"(ºBrix/acidez titulável), sólidos totais, sólidos insolúveis e detecção de íons alumínio e análises microbiológicas (contagem total de bactérias mesofílicas e contagem de leveduras e bolores). As análises de variância dos resultados indicaram que as condições de processo reais estudadas (82,5ºC - 35 s; 82,5ºC - 45 s; 87,5ºC - 35 s e 87,5ºC - 45 s) não influenciaram as características físico-químicas do suco (pH, ºBrix, acidez titulável, “ratio"). Durante o período de armazenamento testado (57 dias), foi verificado que não houve aumento do conteúdo de íons alumínio no suco de laranja e os valores encontrados foram abaixo do limite tolerado de ingestão semanal de alumínio (Provisional Tolerable Weekly Intake – PTWI) estabelecido pela FAO/WHO. Sob o aspecto microbiológico (contagem total de bactérias mesofílicas e contagem de leveduras e bolores), foi verificada a eficiência do processo de pasteurização. Para as condições de processo 82,5ºC – 45 s e 87,5ºC – 45 s, o número de bactérias mesofílicas sobreviventes diminuiu com o tempo de armazenamento. Para as condições 82,5ºC – 35 s e 87,5ºC – 35 s, houve aumento do número de sobreviventes a partir do 23º dia e 33ºdia, respectivamente, em relação ao suco não-processado. As condições de processo empregadas indicaram, no período de armazenamento testado (57 dias), valores de contagem de leveduras e bolores inferiores ao limite máximo tolerado pela Legislação Brasileira para suco “in natura" (104 UFC/mL). / In this research project, minimal heat treatment was studied for fresh single- strength orange juice. The juice was packaged in aluminum cans and stored at refrigerated temperature during 57 days concerning shelf life tests. The juice was processed using a plate heat exchanger at nominal pasteurization temperatures 80ºC and 85ºC and packaged in aluminum varnished cans at ambient temperature, under nitrogen atmosphere. The analyses, conducted each 14 days (1st, 15th, 29th, 43rd and 57th day after the processing day), were: pH, ºBrix, titratable acidity as citric acid, ratio (ºBrix/ titratable acidity), total solids, water-insoluble solids, aluminum ions content and microbiological analyses (total plate count and yeast and mold count). Statistical analyses indicated that the physic-chemical characteristics of orange juice were not influenced by the real process conditions (82.5ºC - 35 s; 82.5ºC - 45 s; 87.5ºC - 35 s and 87.5ºC - 45 s). The orange juice aluminum ions content did not increase during the 57 days storage and all the values were lower than the Provisional Tolerable Weekly Intake (PTWI) established by FAO/WHO. In addition, the pasteurization process showed effective in reducing microbial load. For the temperature-time conditions 82.5ºC - 45 s and 87.5ºC - 45 s, the number of surviving organisms decreased as the storage period increased. However for the temperature-time conditions 82.5ºC - 35 s and 87.5ºC - 35 s, there was an increase of the number of surviving organisms after 23rd day and 33rd day, respectively, compared to raw orange juice. During the 57 days storage, the yeast and mold count were lower than the maximum acceptable limit established by Brazilian Legislation (104 CFU/mL).
480

Efeito do tratamento térmico nas propriedades ópticas de pontos quânticos emitindo na faixa espectral de 1,3 a 1,5 üm

Martins, Marcio Roberto [UNESP] 29 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-29Bitstream added on 2014-06-13T20:21:46Z : No. of bitstreams: 1 martins_mr_dr_bauru.pdf: 576235 bytes, checksum: cae5dc5f897a536d60d112303dafaf34 (MD5) / Secretaria de Educação do Estado de São Paulo / Neste trabalho investigamos pontos quânticos de InAs sobre um substrato de GaAs crescidos pela técnica de epitaxia por feixe molecular (MBE, Molecular Beam Epitaxy). Esses pontos quânticos emitem radiação no intervalo de 1,3 üm a 1,5 üm (0,95 eV a 0,83 eV), que corresponde à janela óptica onde ocorre a mínima atenuação do sinal em redes de transmissão por fibras ópticas. Realizamos dois tipos de estudo em dois conjuntos de amostras. No primeiro caso analisamos a influência de alguns parâmetros de crescimento nas propriedades ópticas desses pontos quânticos. No segundo caso, analisamos a influência de um tratamento térmico nas propriedades ópyicas. Resultados de fotoluminescência (PL - photoluminescence) para o primeiro estudo mostraram uma grande influência da velocidade de crescimento nos espectros de emissão que apresentaram múltiplos picos, muito provavelmente associados com o estado fundamental e seus respectivos estados excitados dos pontos quânticos. Para o segundo estudo os resultados de PL mostraram que a emissão óptica consistia de uma larga banda situada entre 1,3 a 1,5 üm. Entretanto, observou-se que, após tratamento térmico durante 3 horas a uma temperatura de 550 ºC, a intensidade da PL aumentou por um fator 3. Além disso, a larga banda observada tornou-se um conjunto de pelo menos 5 picos discretos. O efeito de tratamentos térmicos em poços quânticos é bem conhecido e foi bem explorado na literatura. Em pontos quânticos, os mesmos efeitos também existem, porém, outros de igual importância tembém se apresentam. Dentre os mais importantes podemos citar a redistribuição dos tamanhos dos pontos quânticos, que podem em alguns casos limites fazer com que o ponto quântico desapareça, e a redistribuição das tensões entre a interface ponto quântico/matriz. Neste trabalho... / This study investigated InAs large quantum dot on GaAs substrate grown by the techique of molecular beam epitaxy (MBE). These quantum dots emit in the spectral range of 1.3 üm and 1.5 üm (0.95 eV to 0.83 eV), which corresponds to the window of minimal signal attenuation on transmission networks by optical fiber. We have performed two kinds of study into two different sets of samples. In the first case, we have analyzed the influence of some growth parameters on the optical properties of these quantum dots. In the second one, we have analyzed the influence of a thermal treatment on the optical properties. Results of photoluminescence (PL) on the first study showed a great influence of growth velocity in the PL spectra line shape. For the second study the results of PL on an as grown sample showed that the emission signal was a large optical band in the wave length range of 1.3 üm and 1.5 üm. However, it was observed that after the thermal treatment of 3 hours at a temperature of 550 ºC, the intensity of these PL emissions increased by a factor 3. Moreover, the observed large band has become a series of at least 5 discrete peaks. The effect of heat treatments in quantum wells is well known and has been well explored in literature. In quantum dot, the same effects are expected; however, other equally important effects are also present. The most important is the size redistribution of the quantum dots, which can in some limit cases, vanish these quantum dot. Our study identified the origin of these multiple peaks, and found emissions of PL at room temperature in the optical window between 1.3 and 1.5 üm.

Page generated in 0.0966 seconds