• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Análise numérica e experimental dos efeitos da não-uniformidade da espessura em cascas finas cilíndricas rotativas. / Numerical and experimental analysis of the thickness non-uniformity effects in rotating circular cylindrical shells.

Marco Antonio Brujas 17 May 2007 (has links)
Cascas cilíndricas circulares com uma pequena variação de espessura ao longo de seu comprimento, quando submetidas à rotação, apresentam em alguns casos, deslocamentos elásticos de sua superfície externa, tendendo a uma forma de um oval. O objetivo deste trabalho é estabelecer a relação entre a variação de espessura das cascas cilíndricas com a sua deformação devida às forças centrífugas medida durante a rotação utilizando-se dois enfoques, um experimental e outro numérico, no caso o método de elementos finitos (MEF). As cascas cilíndricas estudadas tiveram sua espessura de parede medidas por meio de aparelho de ultra-som, mas por serem fabricadas em ferro fundido cinzento, as suas lamelas de grafita atuam como refletores, o que torna a medição imprecisa. Os resultados da análise numérica encontrados se relacionam bem com os experimentais de maneira qualitativa, mas divergem na forma quantitativa. Modelos de cascas com variação de espessura imposta também foram criados e analisados usando-se o método de elementos finitos de forma a se avaliar o comportamento da casca cilíndrica sob diversas configurações de distribuição da variação da espessura. Sugere-se a pesquisa de novas tecnologias para medições por ultra-som de peças fabricadas de ferro fundido com grafita lamelar. Neste trabalho, a medição da forma oval foi feita utilizando-se sensores de proximidade do tipo \"eddy-current\". / Circular cylindrical shells with small thickness variations along their body, when submitted to rotation, present, in some cases, elastic displacements of their outside surface induced by centrifugal forces leading to final oval like shapes. The main purpose of this study is to establish relationships between thickness variation of the cylindrical shells with their measured deformation during the rotation, due to centrifugal forces, using two approaches, one experimental and the other one numerical, in the latter case the finite element method (FEM). The studied cylindrical shells had their wall thickness measured by means of an ultrasound device. The used material is flake graphite cast iron (gray cast iron). The graphite flakes act as reflectors, what makes such measurements imprecise. The numerical results found are satisfactory in a qualitative way, but they disagree in the quantitative form. Shell models with theoretical imperfections also were created and analyzed using the finite element method in order to evaluate the behavior of the cylindrical shell under several configurations of distribution of the shell thickness variation. Further research is necessary on new technologies to measure the thickness of pieces manufactured of flake graphite cast iron. In this research, the oval shape measurements were done by means of eddy-current proximity sensors.
272

Desenvolvimento de sistema de sensoriamento de posição e atuação para posicionamento dinâmico de modelos reduzidos em tanque de provas. / Development of both sensing and actuation infra-structure for the performance evaluation of Dynamic Positioning Systems for reduced scale model of ships in towing tanks or offshore tanks.

Alessandro de Oliveira Santos 28 March 2005 (has links)
Este trabalho tem como objetivo central o desenvolvimento da infra-estrutura de sensoriamento e atuação para a avaliação de Sistemas de Posicionamento Dinâmico de modelos reduzidos de embarcações em tanques de provas. Ele descreve a concepção, o projeto, a implementação e os testes de um sistema sensor de posição e orientação do modelo, assim como o hardware dos propulsores utilizados como atuadores do modelo. O sistema sensor é baseado na emissão e recepção de sinais acústicos sincronizados de alta freqüência (ultra-som). Utiliza-se o Método Esférico 3-D como algoritmo de triangularização, obtendo-se a estimativa da posição por meio da minimização de uma medida quadrática do erro. Além disso, foi também aplicado o filtro estendido de Kalman como algoritmo de estimação. São apresentadas de forma clara e objetiva as dificuldades encontradas no decorrer do desenvolvimento do trabalho, bem como as soluções adotadas para contorná-las, analisando as influências das condições atmosféricas e do ambiente laboratorial no processo de medição, os resultados obtidos a partir dos ensaios, a robustez e o desempenho do sistema sensor. / The main objective of this work is the development of both sensing and actuation infra-structure for the performance evaluation of Dynamic Positioning Systems for reduced scale model of ships in towing tanks or offshore tanks. It describes the conception, design, implementation and tests of a range and orientation sensor system, as well as the hardware of the propellers used as the model actuators. The sensor system is based on the emission and reception of high frequency synchronized accoustic signals (ultra-sound). A 3-D spherical method based on the minimization of a quadratic measure of the error is used to estimate the position of the ship model. Furthermore the extended Kalman filter is also used. The difficulties found during the development of the project are presented as well as the solutions adopted to circumvent them. The experimental results obtained are discussed. In particular, the influence of both the local atmosphere and the lab environment on the performance of the sensor system are taken into account.
273

Ultra-som pulsado de baixa intensidade na regeneração nervosa periférica de ratos / Effect low-intensity pulsed ultrasound in peripheral nerve regeneration of the rats

Daiana Sganzella 27 August 2007 (has links)
O ultra-som é uma das formas de tratamento terapêutico, não-invasivo, que pode auxiliar na regeneração nervosa periférica. Dentre todas estas técnicas não-invasivas de regeneração nervosa periférica, pouco se sabe sobre a influência do ultra-som na regeneração desse tecido. Para tanto foi realizado um trabalho experimental com o objetivo de avaliar o efeito da terapia do ultra-som pulsado de baixa intensidade após lesão por esmagamento do nervo ciático de rato. Foram utilizados 26 ratos Wistar machos, com massa corporal média de 289,61g divididos em 3 grupos: normal (N), lesado (L) e lesado+ultra-som (L+US). A aplicação do ultra-som pulsado (1 MHz, 40 mW/\'CM POT.2\', 8 minutos de duração) iniciou-se 1 dia pós-lesão e repetido por 4 semanas em dias alternados. A análise funcional do nervo ciático (análise de marcha em pista) foi avaliada semanalmente durante todo o período experimental. Para verificar a eficácia do ultra-som sobre a regeneração nervosa foram analisados índice funcional do ciático, morfologia do nervo ciático e morfologia e morfometria muscular dos músculos tibial anterior (TA) e sóleo (SOL). Concluiu-se que o tratamento com o ultra-som pulsado de baixa intensidade na regeneração nervosa periférica não obteve resultados significativos quando se comparou os grupos lesado e lesado+ultra-som, apenas foi observada uma manutenção da área de secção transversa do grupo lesado+ultra-som do músculo TA quando comparado ao grupo normal, levando a indícios de que o ultra-som estimulou o nervo para tal manutenção. / The ultrasound is one of the forms therapeutic treatment, no-invasive, that it assists in regeneration peripheral nerve. For in such a way an experimental work was carried through with the objective to verify the effect of the therapy of low intensity pulsed ultrasound after crush of sciatic nerve. Amongst all these no-invasive techniques of regeneration peripheral nerve, little known on the influence of the ultrasound in the regeneration of this tissue. Twenty six male Wistar rats weighing 289,61 g on average were used and divided into three groups: normal (N), injury (L) and injury+ultrasound (L+US). The application of the pulsed ultrasound (1 Mhz, 40 mW/\'CM POT.2\' and 8 minutes duration) was started one day after lesion and repeated for 4 week in alternate day. The functional analysis of the sciatic nerve (analysis of the march in track) was evaluated at weekly during all the experimental period. To verify the effectiveness of the ultrasound on nerve regeneration they had been analyzed sciatic functional index, morphology of the sciatic nerve and muscle morphology and morfometry of the muscles tibial anterior (TA) and sóleo (SOL). It was concluded that the treatment with the device of ultrasound of low intensity in regeneration peripheral nerve did not get resulted significant when compared the groups injured and injury+ultrasound, was only observed a maintenance of the cross-sectional area of the group injury+ultrasound of the muscle TA when compared with the normal group, taking the indications of that the ultrasound stimulated the nerve for such maintenance.
274

Avaliação in vitro da remoção da camada residual (smear layer) de canais radiculares achatados instrumentados com quatro diferentes sistemas rotatórios com e sem associação de ultra-som e laser ER:YAG / Evaluation of smear layer removal of flatted canals after rotary instrumentation with four diferent NiTi instruments and association with Laser Er:YAG and ultrasonic

Alexandre Capelli 13 March 2008 (has links)
Estudou-se, por meio da microscopia eletrônica de varredura, a remoção da \"smear layer\" dos canais radiculares preparados com sistemas rotatórios com e sem \"radial land\". Após a preparação, as paredes dos canais radiculares foram submetidas aos tratamentos com ultra-som, aplicação do agente quelante EDTA a 15% e do laser Er:YAG. Noventa e seis incisivos inferiores humanos foram selecionados e divididos aleatoriamente em quatro grupos distintos, preparados com técnica rotatória Free Tip (Pecora et al, 2002) com instrumentos de níquel-titânio, 0,5 mm aquém do ápice anatômico, variando-se apenas o tratamento final das paredes do canal radicular. No grupo 1 utilizou-se o hipoclorito de sódio a 2,5% durante a instrumentação; no grupo 2 realizou-se irrigação com hipoclorito de sódio a 2,5% durante a instrumentação, recebendo posteriormente irradiação com laser Er:YAG (KaVo Key Laser II), com o auxílio de uma fibra óptica 30/28 de 285 &micro;m de diâmetro, gerando uma energia total de 42 J, freqüência de 15 Hz e potencia de 250mJ input (140mJ output). A cinemática utilizada na irradiação foi de movimento helicoidal de tração da fibra óptica, de apical para cervical, durante 10 segundos, sendo repetida quatro vezes; no grupo 3 utilizou-se a solução de hipoclorito de sódio a 2,5% ativada pelo ultra-som (MiniPiezon, EMS, Suíça); no grupo 4 utilizou-se a solução de hipoclorito de sódio a 2,5% e irrigação final com EDTA a 17%. Os espécimes foram preparados para microscopia eletrônica de varredura, e as fotomicrografias obtidas dos terços médio e apical submetidas a avaliação qualitativa por três observadores previamente calibrados, que atribuíam escores as imagens. A análise estatística revelou que a presença ou ausência da superfície radial de apoio (radial land) não interferiu na limpeza das paredes dos canais radiculares. Com relação ao tratamento final, o EDTA a 15% foi capaz de eliminar a \"smear layer\" com maior eficácia, sendo seguido pelo ultra-som e finalmente o laser Er:YAG. Houve diferença estatística significante entre os terços médio e apical dos canais radiculares. / This study evaluated, in vitro, smear layer removal in apical and middle root thirds after instrumentation with four different rotary Ni-Ti instruments and the use of Er:YAG laser, ultrasonic or EDTA. Nineth six mandibular incisors root canals were instrumented with Free Tip Technique, and irrigated with 10 ml of sodium hypochlorite. In Group 1, 24 teeth were instrumented and irrigated only with 10 ml of 2.5 % sodium hypochlorite. Group 24, instrumented as group 1 and irradiated laser Er:YAG in the following parameters: 30/28 fiber optic tip, 42 J, 15Hz and 250mJ input (140mJ output), with the tip activated at the apex and removed to the canal entrance in a helicoidal moviment. Group 3, instrumented as in group 1 and associated with ultrasonic. Group 4, instrumented as in group 1 and associated with with 15% EDTA. Electronic Microscope images were evaluated showed that group 4 had significantly less smear layer (p<0,05) than the group 1 and 2, with group 3 in intermediated position. We conclude that sodium hypochlorite associated with 15% EDTA lead to root canals with less smear layer. The middle third present less smear layer than apical third.
275

Estudo comparativo dos efeitos do ultra-som e do laser de baixa intensidade no reparo ósseo de tíbia de rato / Comparative study of ultra-sound and low intensity laser therapy effects on bone healing in rats tibia

Ana Paula Rebucci Lirani 24 March 2004 (has links)
Vários estudos têm avaliado os efeitos do ultra-som e da radiação laser de baixa intensidade separadamente no reparo ósseo. No entanto, são escassas as comparações entre estas duas modalidades terapêuticas. Este estudo teve por objetivo avaliar e comparar, através de análise histomorfométrica e ensaio mecânico de flexão em três pontos, as conseqüências que estes agentes físicos podem trazer ao reparo do tecido ósseo em osteotomias transversais experimentais em tíbias de ratos. Foram utilizados 48 ratos com fratura cirúrgica unilateral parcial do terço superior de tíbia. Os animais foram divididos em três grupos de 16 animais. Em um grupo, o membro fraturado foi tratado com ultra-som pulsado de baixa intensidade (freqüência de 1,5 MHz, ciclo de trabalho 1:4, intensidade SATA 30 mW/centímetro quadrado) em sessões de 20 minutos, 5 vezes por semana, em 12 dias de tratamento. Em um segundo grupo, o membro fraturado foi tratado com laser As-Ga-Al (112,5 J/centímetro quadrado, 780 nm, 30 mW) em sessões de 2,5 minutos, 5 vezes por semana, em 12 dias de tratamento. O terceiro grupo serviu de controle, sendo submetido à mesma cirurgia na tíbia direita mas não recebeu qualquer tratamento. No ensaio mecânico, a carga no limite máximo suportada pelo grupo tratado com laser foi significantemente maior (p < 0,05) que os grupos tratado com ultra-som e controle. Na análise histomorfométrica, o grupo tratado com laser apresentou significância estatística quanto ao número e superfície de osteoblastos e volume e superfície de osteóide e o grupo ultra-som obteve significância para as superfícies de reabsorção e de osteoclastos. Pode-se concluir que o ultra-som acelerou o reparo ósseo (em relação ao grupo controle) por viabilizar mais rapidamente a fase de reabsorção, enquanto que a terapia laser foi capaz de acelerar ainda mais este processo por já promover predomínio de formação óssea no décimo nono dia pós-cirúrgico no modelo experimental utilizado neste estudo / Many studies have assessed the effects of ultra-sound and low intensity laser therapy separatedly in bone repair. However, the comparison between these two therapeutic modalities is rare. The objective of this study was to verify and compare, through histomorphometrical analysis and a three-point bending test, the consequences of these physical agents on bone healing in animals. 48 male Wistar rats were used with tibial bone partial osteotomy, divided into 3 groups of 16. In one group, rats had their fractured limb treated with GaAIAs laser (780 nm, 30 mW, 112,5 J/square contimeter) in 12 five times-a-week sections. In another group, rats were treated with low intensity pulsed ultra-sound (1,5 MHz, 30 mW/square centimeter) in 12 five times-a-week sections too. In a third group, animals were taken as control, being submitted to the same osteotomy but receiving no treatment. After 19 days the tibias were extracted and half of them were submitted to a three-point bending test and the other half to histomorphometric analysis. During the bending test, the maximum load at failure of the tibia in the laser group was significantly higher (p<0.05). Histomorphometry showed statistical significance in osteoblasts number and surface and osteoid volume and surface for the laser group, and eroded and osteoclasts surfaces for the ultra-sound group. Ultra-sound was able to enhance bone healing (compared to control group) by speeding up the reabsorption phase, while low intensity laser therapy could accelerate this process even more by promoting mostly new bone formation 19 days after osteotomy in this experimental model
276

\"Estudo da influência de instrumentos e técnicas alternativas de preparo cavitário na resistência de união de sistema adesivos à dentina\" / Study of the influence of alternative tools and techniques of cavity preparation on teh bond strength of adhesive system to dentin

Marcio Vivan Cardoso 15 January 2007 (has links)
A atual tendência ao desenvolvimento de uma odontologia minimamente invasiva tem sido responsável pela introdução de instrumentos e técnicas alternativas de preparo cavitário. Porém, tais tecnologias deveriam não somente preencher os requisitos de uma odontologia conservadora, mas também preparar as paredes da cavidade para o tratamento restaurador adesivo subseqüente. Assim, o objetivo deste estudo foi testar a hipótese nula de que: 1) tanto técnicas convencionais quanto técnicas alternativas de preparo cavitário são capazes de produzir um substrato dentinário receptivo à adesão de sistemas autocondicionantes; e 2) A efetividade adesiva de sistemas autocondicionantes não é influenciada pela interposição da camada de esfregaço. Cem molares humanos íntegros foram aleatoriamente divididos em 20 grupos de acordo com o adesivo e a técnica ou instrumento utilizado. Superfícies planas de dentina média oclusal foram preparadas com instrumento rotatório diamantado convencional (IR); fratura; instrumento rotatório CVD (IRCVD); instrumento ultra-sônico CVD (IUCVD); e laser de Er,Cr:YSGG .Um adesivo condicione-e-lave (Optibond FL/OB) e três autocondicionantes (Adper Prompt L-Pop/AP, Clearfil SE Bond/SE e Clearfil S3 Bond/S3) foram empregados. Os espécimes foram construídos com o compósito Z100/3M ESPE. A resist6encia adesiva foi determinada por meio de teste de microtração após 24 h de estocagem em água a 37oC. Amostras adicionais foram processadas para análise em MEV quanto às características morfológicas apresentas após o preparo das superfícies dentinárias em cada caso. O teste de Kruskal-Wallis (p<0,05) determinou que os grupos preparados com IRCVD, IUCVD e laser apresentaram menores valores de resistência adesiva quando comparados aos grupos controle (IR e fratura). Além disso, os adesivos de menor acidez (SE e S3) foram mais eficientes quando aplicados em dentina fraturada. Concluiu-se que o uso de instrumentos e técnicas alternativas de preparo cavitário comprometeu a adesão à dentina e que a camada de esfregaço influencia de forma negativa a adesão de sistemas autocondicionantes suaves. / The current trend toward minimal invasive dentistry has introduced alternative cavity preparation techniques. However, these technologies should not only fulfill the requirements of a conservative philosophy, but also prepare the cavity walls for the subsequent bonding restoration. The purpose of this study was to assess the null hypotheses that: (1) both conventional and alternative cavity preparation techniques are equally receptive to adhesion; and (2) bonding effectiveness of mild adhesives is not influenced by smear layer (SL) interposition. Eighty sound human molars were divided into 20 groups according to adhesive and cavity preparation technique. Flat mid-occlusal dentin surfaces were prepared with regular diamond bur (DB), scalpel blade (SB), CVDentus bur in high speed turbine (CB), CVDentus tip in ultrasound (CT), and Er,Cr:YSGG laser (L). One etch-and-rinse (Optibond FL (OB)) and three self-etch systems (Adper Prompt L-Pop (AP), Clearfil SE Bond (SE) and Clearfil S3 Bond (3S)) were employed. Specimens were built up with Z100/3M ESPE composite. The microtensile bond strength was determined after 24h of storage in water at 37oC. Additional samples were processed for SEM analysis on morphological aspects in each situation. Kruskal-Wallis test (p<0,05) determined that groups prepared with CB, CT and L presented lower ?TBS values than the control groups (DB and SB), and that adhesives with lower acidity (SE and 3S) were more effective when applied on fractured surfaces (SB). It was concluded that the use of alternative techniques for cavity preparation caused damages to dentin surface, compromising the adhesion to this substrate. Moreover, the bonding effectiveness of mild adhesives was improved by SL absence.
277

Estratégias de manejo para aumentar a eficiência reprodutiva de fêmeas equinas da raça Mangalarga Marchador / Strategies for management to increase efficiency of reproductive mares of breed Mangalarga Marchador

TAVEIROS, Adriana Wanderley 28 February 2008 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2016-07-28T11:38:58Z No. of bitstreams: 1 Adriana Wanderley Taveiros.pdf: 657445 bytes, checksum: 7c3d82e0aa3e31bc2f15930aca51db7c (MD5) / Made available in DSpace on 2016-07-28T11:38:58Z (GMT). No. of bitstreams: 1 Adriana Wanderley Taveiros.pdf: 657445 bytes, checksum: 7c3d82e0aa3e31bc2f15930aca51db7c (MD5) Previous issue date: 2008-02-28 / In the experiment 01 the purpose of this work was to optimize the reproductive potential of embryos donors (n = 5) of the Mangalarga Marchador breed submitted to an annual program of embryo production. In Southeast Region, Três Rios – RJ, the embryo recovery was performed between November/2005 and April/2006 and in Northeast Region from May to December/2006. The donors and recipients mares were monitored every other day by rectal and ultrasonographic examinations until they ovulated. On the eight days after ovulation the uteri of the donors were flushed with lactated Ringer’s solution and the embryos were immediately transferred to the recipients mares, which were examined eight days later to confirm the pregnancy. Eighty flushes provided 69 (86.3%) embryos with 37 (53.6%) pregnancies, result that showed the possibility to produce embryo over the whole year. The donors produced, in the Southeast Region, 7.8±1.4 embryos and 4.0±1.0 pregnancies and in Northeast Region, 6.0±2.0 embryos and 3.4±1.1 pregnancies. With this alternative in the program was possible to obtain additionally 6.0 embryos and 3.4 pregnancies. The results allow recommending the use of embryo donors over the whole year because provide higher number of birth, as well as accelerate the genetic breed horse development. In the experiment 02 The purpose of this study was to compare the effectiveness of techniques such as artificial insemination and embryo transfer, with the indices of embryonic death occurred in the conduct of these techniques, during the years of 2003 to 2006. Mares were used racial mangalarga marchador aged ranging between 05 and15 years. The mares were divided into two groups: Artificial Insemination (Group 01) and transfer of embryos (Group 02). Both groups were monitoring the cycle estral on alternate days with the help of ultra-sonography, being inseminated by ovulation from the detection of the beginning. In animals belonging to the group 01 the diagnosis of pregnancy was performed in the 15-day post - ovulation with monitoring in the days 30, 45 and 60 of gestation. In Group 02 on the eighth day post - ovulation was held the harvesting of embryo by open method, using the solution with lactated Ringer, washed positive for embryo were inoculated in receiving in good conditions that have their reproductive cycle estral controlled until ovulation. Only the embryos were inoculated ranked from 01 to 03. In this group the diagnosis of pregnancy was performed in 05 ° day after inovulação in receiving and monitoring was performed on days 15, 30, 45 and 60 of gestation. Between the years of 2003 and 2006 the group 01 received half year around 11.6%, while in group 02 to annual average was around 12%. The results suggest that allows no interference from the implementation of the techniques in rates of embryonic loss. In the experiment 03 This aim of this study was to diagnostic previously the gender of equine fetuses (n = 157) of Mangalarga Marchador by ultra-sound, identifying the final position of the genital tubercle or viewing the anatomical structures of external genitalia. The exams were realized in alternate days, by via transrectal, between 58º and 69º, as well as between 90º and 150º dayof pregnancy. The mares were artificially inseminated on the ovulation day and this day was considered as pregnancy day (Day 0). The pregnancy diagnosis was performed on the 15º day after ovulation. There was not observed difference (P > 0. 05) on the fetal sexing accuracy between male (95.6%) and female fetuse (91.4%). However, was verified that the accuracy of the exam realized takin into consideration the genital tubercle (90.1%) was lower (P < 0. 05) than exam made takin into consideration the genital structures (93.7%). The results allow to conclude that the ultrasound is a suitable method to early diagnostic the fetal sex by identification of final position of genital tubercle, especially by visualization of anatomical structures of external genitalia. / Neste trabalho objetivou-se aumentar a eficiëncia reprodutiva de fëmeas da raça Mangalarga Marchador. No Experimento 01 o objetivou-se otimizar o potencial reprodutivo de doadoras (n = 5) de embrião da raça Mangalarga Marchador submetidas a um programa anual de produção de embrião. Na Região Sudeste, Três Rios – RJ, as colheitas foram realizadas entre novembro de 2005 e abril de 2006 e na Região Nordeste, Limoeiro – PE, de maio a outubro de 2006. As doadoras e receptoras foram monitoradas, em dias alternados, por palpação retal com auxílio de ultra-som até a ovulação. As doadoras foram inseminadas também em dias alternados até a ovulação. No oitavo dia após a ovulação foi realizada a lavagem uterina com a solução Ringer-Lactato e os embriões foram imediatamente transferidos para as receptoras, as quais foram examinadas sete dias após para confirmação da gestação. De 80 lavados efetuados foram recuperados 69 (86,3%) embriões com 37 gestações (53,6%), resultado que evidenciou ser possível manter a produção de embriões na espécie eqüina durante todo o ano. As doadoras na Região Sudeste produziram 7,8±1,4 embriões com 4,0±1,0 gestações e no Nordeste produziram 6,0±2,0 embriões com 3,4±1,1 gestações. Com esta alternativa no programa foi possível obter adicionalmente 6,0 embriões e 3,4 gestações. Os resultados permitem concluir que é recomendável utilizar doadoras de embrião durante todo o ano porque propicia maior número de nascimentos,bem como acelera o melhoramento genético do rebanho.No experiento 02 o objetivo foi monitorar o período crítico da perda embrionária/fetal em programa de inseminação artificial e de transferência de embriões eqüinos da raça Mangalarga Marchador. O experimento foi realizado entre os anos de 2003 e 2006, na Fazenda Pedra Verde localizada no Estado de Pernambuco. Foram utilizadas 340 éguas da raça Mangalarga Marchador durante os quatro anos de experimento. As éguas foram distribuídas no grupo da inseminação artificial e no da transferência de embriões. Todas as fêmeas foram monitoradas, em dias alternados, por palpação retal com auxílio de ultra-som até a ovulação. As fêmeas da inseminação artificial e as doadoras foram inseminadas em dias alternados até a ovulação. No oitavo dia após a ovulação foi realizada a lavagem uterina com a solução Ringer-Lactato nas doadoras e os embriões foram imediatamente transferidos para as receptoras. Os diagnósticos de gestação foram realizados no 15° dia após a ovulação nas fêmeas artificialmente inseminadas e no 7° dia após a transferência do embrião, sendo todas monitoradas nos dias 20, 25, 30 e 45 de gestação para avaliação de possível perda embrionária. Das éguas artificialmente inseminadas obteve-se 879 gestações, sendo que 94 (10,7%) resultaram em perda embrionária/fetal, enquanto no programa de transferência de embrião, das 338 gestações resultantes, 40 (11,7%) resultaram em perda. No programa de transferência as perdas embrionárias foram mais tardias,provavelmente, devido ao retardo na implantação do embrião. Não foi constatada diferença significativa (P > 0,05) entre as perdas embrionárias ocorridas na inseminação artificial ena transferência de embrião. Os resultados permitem concluir que a perda embrionária precoce não está relacionada com a inseminação artificial ou com a transferência de embriões, desde que sejam adotadas práticas de manejo semelhantes para todas as fêmeas.Quanto ao período de gestação em que ocorreu a perda embrionária foi constatada uma queda significativa (P < 0,05) do 31º ao 40º dia de gestação. No experimento 03 objetivou-se diagnosticar precocemente o sexo de fetos eqüinos (n = 157) da raça Mangalarga Marchador por ultra-som, identificando-se a posição final do tubérculo genital ou visualizando-se as estruturas anatômicas da genitália externa. Os exames foram realizados em dias alternados, por via transretal, entre o 58º e o 69º, bem como entre o 90º e o 150º dia de gestação. As éguas foram artificialmente inseminadas no dia da ovulação, o qual foi considerado como o dia 0 da prenhez. O diagnóstico de gestação foi realizado no 15° dia após a ovulação. Não foi observada diferença (P > 0,05) na acurácia da sexagem entre feto macho (95,6%) e fêmea (91,4%). Todavia, foi verificado que a acurácia do exame realizado apenas com base no tubérculo genital (90,1%) é menor (P < 0,05) do que a do exame efetuado considerando as estruturas da genitália externa (93,7%). Os resultados permitem concluir que o ultra-som é um método apropriado para diagnosticar precocemente o sexo fetal através da identificação da posição final do tubérculo genital, especial pela visualização de estruturas natômicas da genitália externa.
278

Estudo comparativo entre extração Soxhlet e ultrasom para determinação de hidrocarbonetos policíclicos aromáticos em sedimentos do estuário do rio Sergipe por cromatografia a gás acoplada a espectrometria de massas / COMPARATIVE STUDY OF EXTRACTION SOXHLET AND ULTRASOUND DETERMINATION FOR OIL POLYCYCLIC AROMATIC SEDIMENTS SERGIPE RIVER ESTUARY BY GAS CHROMATOGRAPHY MASS SPECTROMETRY ATTACHED.

Santos, Antonio Sérgio Oliveira dos 26 August 2011 (has links)
Polycyclic aromatic hydrocarbons (PAHs) are compounds that can be found in environmental compartments such as atmosphere, soil, sediment and water. Throughout bioaccumulation, they can also be incorporated into vegetables and animals tissues. They are mainly originated from anthropogenic sources such as fossil fuels and biomass burnings. Due they potential toxicity, carcinogenicity and mutagenicity, they must be carefully monitored. The main goal of this study is to compare two extraction methods (ultrasound and Soxhlet) and the optimization of a cleanup column and chromatographic conditions (GC-MS) for separation and determination of 16 polycyclic aromatic hydrocarbons (PAHs) established as priorities by the Environmental Protection Agency of the United States. Once optimized, the method was applied to evaluate HPAs in sediment samples collected in the Sergipe river estuarine system. The extracts were analyzed by GCMS, using a DB-5 capillary column, splitless injection and operating in SIM mode, with three ions being monitored for each PAH, one ion principal and two others as confirmation ions. We conducted a validation study of the methods. The analytical curves showed coefficients of determination (R2) above 0.99 for all 16 PAHs. For the ultrasound method, the average recovery obtained in two fortification levels (12.5 ng g-1 and 62.5 ng g-1) showed no significant differences, with a recovering average ranging from 74 to 125.4% and RSD <19.2% for all compounds analyzed, except for pyrene. The limits of detection and quantification by ultrasound ranged from 0.04 to 0.23 ng g-1 and 0.12 to 0.78 ng g-1, respectively, and the limits of detection and quantification by Soxhlet ranged from 0.03 to 0.3 ng g-1 and 0.11 to 1.0 ng g-1, respectively. On the other hand, the Soxhlet extraction did not show good recoveries for low molecular weight PAHs, especially naphthalene, acenaphthylene and acenaphthene, with values ranging from 9.5 to 98.4%. Therefore, the extraction method chosen for the analysis of PAHs in sediment was the ultrasound. It showed good recovery, speed, solvent and adsorbent economy and low extraction time. It also allows simultaneous extraction of several samples. The total concentrations of PAHs in the sediments studied ranged from 6.7 ng g-1 to 377.7 ng g-1 dry weight. The species found in higher concentrations were Benzo[ghi]Perylene (61.9 ng g-1), chrysene (52.7 ng g- 1), fluoranthene (47.9 ng g-1) and pyrene (34.1 ng g-1). The investigation of the PAHs sources suggests pyrogenic origin for most of the compounds. / Os hidrocarbonetos policíclicos aromáticos (HPAs) são compostos que podem ser encontrados em diversos compartimentos ambientais tais como atmosfera, solo, sedimento e água. Por bioacumulação podem também estar incorporados aos organismos vegetais e animais. São originados, principalmente, de fontes e/ou atividades antrópicas, como a queima de combustíveis fósseis e da biomassa. Devido ao seu potencial tóxico, carcinogênico e mutagênico, eles devem ser cuidadosamente monitorados. O presente trabalho tem como objetivo a comparação de dois métodos de extração (ultra-som e Soxhlet), otimização de uma coluna (clean up) e das condições cromatográficas (GC-MS) para a separação e determinação dos 16 hidrocarbonetos policíclicos aromáticos (HPAs), estabelecidos como prioritários pela Agência de Proteção Ambiental dos Estados Unidos, em amostras de sedimentos coletadas no estuário do rio Sergipe. Os extratos foram analisados por GC-MS utilizando coluna capilar DB-5, injeção no modo splitless e operando no modo SIM, selecionando um íon principal e dois de confirmação de cada HPA. Foi realizado um estudo de validação dos métodos. As curvas analíticas apresentaram valores de coeficiente de determinação (R2) acima de 0,99 para os 16 HPAs. Pelo método de ultra-som, os valores médios de recuperação obtidos em dois níveis de fortificação (12,5 ng g-1 e 62,5 ng g-1) não apresentaram diferenças significativas, obtendo recuperação média na faixa de 74 a 125,4% e RSD< 19,2% para os compostos analisados, com exceção do pireno. Os limites de detecção e quantificação por ultra-som variaram de 0,04 a 0,23 ng g-1 e de 0,12 a 0,78 ng g-1, respectivamente, enquanto que por Soxhlet variaram de 0,03 a 0,3 ng g-1 e de 0,11 a 1,0 ng g-1, respectivamente. Por outro lado, a extração por Soxhlet não apresentou boa recuperação para os HPAs de baixa massa molar, principalmente, o naftaleno, acenaftileno e o acenafteno, que variou de 9,5 a 98,4%. Portanto, o procedimento escolhido para análise de HPAs em sedimento foi o ultra-som, pois mostrou boa recuperação, rapidez, economia de solvente e adsorvente, baixo tempo de extração, além de permitir a extração simultânea de todas as amostras. As concentrações de HPAs totais nos sedimentos estudados variaram de 6,7 ng g-1 a 377,7 ng g-1 em peso seco. As espécies encontradas em maior concentração foram Benzo[ghi]Perileno (61,9 ng g-1), Criseno (52,7 ng g-1), Fluoranteno (47,9 ng g-1) e Pireno (34,1 ng g-1). A investigação da fonte dos HPAs sugere origem pirogênica para a maioria dos compostos.
279

Tratamento quimico de colmos de bambu pelo metodo de Boucherie modificado / Bamboo culms chemical treatment by Boucherie modificated method

Espelho, Jean Claudio Chiozzini 23 February 2007 (has links)
Orientador: Antonio Ludovico Beraldo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-09T06:15:33Z (GMT). No. of bitstreams: 1 Espelho_JeanClaudioChiozzini_M.pdf: 5138907 bytes, checksum: 875754541cac182e91f3c878f2be3883 (MD5) Previous issue date: 2007 / Resumo: O bambu é uma matéria-prima com múltiplas aplicações, principalmente no setor da construção. Seu desenvolvimento e seu desempenho mecânico são obtidos após um curto intervalo de tempo, quando comparado com as árvores. O bambu é um material renovável e encontrado em abundância em regiões tropicais e subtropicais, nas quais é considerado um material de baixo custo. No entanto, a maior parte das espécies de bambu é altamente susceptível ao ataque de fungos e insetos. Basicamente, pode-se aumentar a durabilidade dos colmos de bambu de duas maneiras, representadas por procedimentos culturais (naturais) e pelo tratamento dos colmos com produtos químicos. Dentre os diversos métodos que visam aumentar a durabilidade do bambu destaca-se o ¿Método de Boucherie Modificado¿. Neste trabalho testou-se a eficiência da aplicação do Método de Boucherie Modificado, comparando o aumento na durabilidade das amostras tratadas (taliscas de bambu) com amostras não tratadas ou testemunhas. Para tal, foram avaliados os efeitos de algumas variáveis como: posição da amostra no colmo, tipos de preservativo e sua concentração, duração do tratamento e tempo de exposição das taliscas em dois ambientes (protegido e exposto). Foram realizados ensaios não destrutivos - END (visual, pesagem das amostras e de ultra-som) e destrutivo (flexão estática). Também foram efetuadas análises químicas (concentração dos elementos químicos nas soluções e seu teor nas regiões do colmo) e de rastreabilidade dos elementos químicos por microscopia eletrônica de varredura (MEV). Os resultados obtidos permitiram verificar a falta de uniformidade da distribuição dos elementos químicos ao longo dos constituintes anatômicos do bambu, ocorrendo a deposição dos mesmos basicamente nos vasos. Verificou-se, igualmente, a ineficiência do uso de soluções com baixa concentração, principalmente quando foram combinadas com tratamentos de curta duração. Os ensaios de ultra-som e de flexão estática foram suficientemente sensíveis para detectar a melhor combinação do efeito dos parâmetros avaliados / Abstract: Bamboo is a raw material with several possibilities of applications, mainly for building purposes. Its development and its mechanical performance are obtained after a short interval of growing when compared with trees. Bamboo is renewable raw material and it is available in tropical and subtropical regions, where it is considered as a cheap material. Nevertheless, the most of bamboo species is highly decayed by insects and fungi attacks. Basically the bamboo culm protection can be obtained by means of a two treatment types: natural protection and chemical protection. In this last category one of the most employed is the Boucherie Modified Method. In this work it was evaluated the performance of a Boucherie Modified Method, comparing treated bamboo samples (bamboo splits) with no treated samples (control). It was evaluated the effect of the sample position in the culm, chemical solution type and its concentration, treatment elongation and the exposition period in two environment (protected and no protected). Non destructive evaluation - NDE (visual, weight control and ultrasound) and flexure test were applied to the specimens along the time. Also chemical analysis (chemical element concentration in the solution and its amount in the bamboo regions) and the traceability of these chemical elements by means a scanning electronic microscope (SEM) were employed. Results obtained showed a lack of uniformity of the distribution of the chemical elements across the bamboo anatomical constituents, occurring the salt deposition mainly in the vessel with a greater diameter. Smaller concentration solutions, mainly when they were combined with smaller treatment time, were not effective to protect bamboo against decay. Results obtained by ultrasound and flexure test were sensitive enough to detect the best combination of the effect of the parameters evaluated. / Mestrado / Construções Rurais e Ambiencia / Mestre em Engenharia Engenharia Agrícola
280

Sistema multicanal de geração e recepção de ondas ultra-sonicas para transdutor matricial linear / Multichannel system for generation and detection of ultrasonic waves with a linear array transducer

Zanella, Fabio Pieroni 19 July 2006 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T02:41:16Z (GMT). No. of bitstreams: 1 Zanella_FabioPieroni_M.pdf: 8365446 bytes, checksum: c1fa57572fdaf7e48b08a6a5fb58a524 (MD5) Previous issue date: 2006 / Resumo: O ultra-som na medicina tem passado por enorme evolução nas últimas décadas e ocupado posição de destaque cada vez maior como ferramenta para terapia e diagnóstico. Isso é devido principalmente ao fato de que os equipamentos de diagnóstico por ultra-som são de relativo baixo custo, o ultra-som é uma radiação não-ionizante e permite realização de exame por método não-invasivo e as imagens são geradas e visualizadas em tempo real. Na geração de imagens deste tipo, é comum a utilização de transdutores matriciais. Entretanto, o Brasil apresenta defasagem tecnológica com respeito à construção destes transdutores e à eletrônica envolvida em sua operação. O objetivo deste trabalho consistiu no desenvolvimento de circuitos eletrônicos com 12 canais de geração e de recepção de ondas ultra-sônicas para operação com transdutor matricial linear. O sistema é capaz de excitar transdutores piezoelétricos e receber ecos ultra-sônicos na faixa de 0,5 a 30 MHz e tem seus circuitos de recepção protegidos contra a alta tensão dos pulsos gerados para a excitação do transdutor. Os disparos dos elementos do transdutor e o tempo de corte dos sinais nos circuitos de recepção, para evitar receber sinais indesejáveis referentes ao período inicial de oscilação do transdutor, são controlados via circuito com microcontrolador PIC 16F877 que, juntamente com o programa de controle, foram desenvolvidos para conectar o sistema a um microcomputador. Os 12 canais foram caracterizados eletricamente e verificou-se seu funcionamento utilizando um transdutor piezoelétrico linear de 12 elementos com 1 MHz de freqüência central, especialmente desenvolvido para este trabalho. Os resultados mostraram que o sistema funciona adequadamente, gerando imagem de um phantom construído em nosso laboratório / Abstract: Ultrasound in medicine has gone through great evolution in the last few decades and has occupied important position as a tool for therapy and diagnosis. This is due to the ultrasound equipment be of relatively low-cost, ultrasound is a non-ionizing radiation, is a non-invasive imaging method, and the images are created and seen in real time. It is common the use of transducer arrays in order to generate this kind of image. There is a lack of know how in Brazil relative to the construction of these transducers and the involved electronics in their operation. The objective of this work was the development of a multi-purpose 12 channel pulser/receiver electronic circuitry to operate with linear transducer arrays. The system is able to fire ultrasound piezoelectric transducers and to receive ultrasound echo signals in the range 0.5-30 MHz. The system has reception circuits with protection against high voltage pulses. The firing of transducer elements and cutting time of the reception circuits, to avoid unwanted signals of natural initial transducer oscillations, can be controlled via PIC 16F877 hardware and software designed to connect the system to a microcomputer. The electrical characteristics of the 12 channel pulser/receiver and its use in firing a specially constructed 1 MHz 12 element PZT transducer array has been carried out and the images of a specially constructed phantom showed that it can be used in laboratory conditions / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Page generated in 0.029 seconds