• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 283
  • 3
  • 2
  • Tagged with
  • 301
  • 114
  • 55
  • 51
  • 43
  • 42
  • 41
  • 36
  • 36
  • 36
  • 35
  • 35
  • 33
  • 32
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Avaliação do leito arterial distal em revascularização de membros inferiores: estudo comparativo entre ecografia-doppler, arteriografia e medidas diretas de fluxo no intra-operatório / Color-flow duplex hemodynamic assessment of runoff in ischemic lower limb revascularization: a comparative study among preoperative duplex scanning, arteriography and intraoperative direct out flow measurements

Rossi, Fabio Henrique 22 September 2006 (has links)
A cirurgia de restauração circulatória arterial no paciente portador de isquemia crítica de membros inferiores apresenta indicações clínicas e técnica operatória já bastante estudadas e definidas. Ainda hoje, no entanto, um considerável número de enxertos evolui para oclusão. Entre as causas relacionadas à falência precoce, podemos destacar a resistência do leito distal receptor do enxerto. Interessou-nos estudar a existência de correlação hemodinâmica entre a Ecografia-Doppler, a Arteriografia pré-operatória, e medidas diretas intra-operatórias de resistência do leito arterial receptor do enxerto. Foram estudadas 68 operações de revascularização de membros inferiores portadores de isquemia crítica. A Ecografia-Doppler foi considerada tecnicamente satisfatória em 93,2%. Foi verificada a presença de correlação hemodinâmica positiva entre os métodos descritos acima (Teste de Pearson), particularmente para as artérias distais. Concluímos que a Ecografia-Doppler, além de definir as características anatômicas da artéria a ser revascularizada, pode auxiliar no estudo hemodinâmico do leito arterial receptor do enxerto e dessa forma auxiliar na definição do prognóstico do enxerto e no estabelecimento da melhor estratégia terapêutica a ser tomada ainda no período pré-operatório / The clinical indications and the surgical technique regarding arterial revascularization in patients with critical lower limb ischemia have been thoroughly studied and well determined in the literature. However, a considerable number of grafts evolutes to occlusion even nowadays. Among the factors known to contribute to early graft failure the resistance of the outflow arterial bed stands out. The purpose of this study is to verify Duplex Scanning hemodynamic correlation power with preoperative arteriography and direct intraoperative resistance measurements. Sixty-eight (68) lower limb revascularizations were studied. Preoperative Duplex Scanning was considered satisfactory in 93,2% of the cases. A positive hemodynamic correlation among the methods described above (Pearson\'s correlation test), particularly for distal arteries, has been verified. We conclude that preoperative Duplex Scanning, apart from defining the anatomic characteristics of the artery to be revascularized, can be helpful in the hemodynamic study of the arterial bed receiving the graft, making it easier to establish the graft prognosis and define the best therapeutic strategy to be adopted in the preoperative period.
212

Previsão de vazões afluentes a usinas hidrelétricas aplicada à programação da operação do sistema elétrico brasileiro / Streamflow forecasting applied to the operation planning of the Brazilian electric power system

Lima, Diana Ruth Mejia de 17 September 2018 (has links)
Este trabalho aborda o problema de modelagem de séries de vazões afluentes aos aproveitamentos hidrelétricos. A previsão de vazão natural fluvial é realizada semanalmente para 158 usinas hidrelétricas do Sistema Interligado Nacional (SIN), pois trata-se de insumo fundamental para o planejamento e operação do sistema elétrico brasileiro. Diversos modelos são utilizados na determinação destas previsões, entre os quais podem ser citados os modelos físicos, os estatísticos e aqueles que aplicam sistemas inteligentes. Apesar de contínuos aprimoramentos terem sido incorporados ao processo de previsão de vazão, existem alguns aproveitamentos hidrelétricos para os quais os resultados de estimação têm apresentado grandes desvios. Neste contexto, com a motivação de se obter uma resposta acurada, investigam-se os sistemas fuzzy como modelos concorrentes aplicados à previsão de vazões semanais. O objetivo do trabalho é reduzir os erros de estimação para uma usina piloto, incorporando à previsão de vazão os dados de precipitação. Para a construção da série histórica de precipitação média da bacia hidrográfica, fez-se uma exaustiva pesquisa por estações pluviométricas, seguida por tratamento de dados de medição e método de interpolação. Ao final do trabalho, é apresentada uma análise comparativa entre os resultados obtidos com o Modelo Autorregressivo Periódico (PAR) e o sistema de inferência fuzzy. Com base no desempenho observado, superior ao modelo autorregressivo, comprova-se a adequação do modelo proposto para a modelagem do processo hidrológico. / This work addresses the modelling problem of hydropower plants reservoir streamflow series. The natural streamflow forecasting for 157 hydroelectric power plants of the National Interconnected System - NIS is updated on a weekly basis, which is an essential input for the planning and operation of the Brazilian Electric Power System. Several models are used to determine this prediction, such as physicals, statisticals and the ones that use intelligent systems. Despite the improvements to natural streamflow forecasting, substantial deviation has been found for the expected results of some hydropower plants. Highlighted the importance of this variable, fuzzy systems applied to weekly streamflows forecasts will be investigated as alternative models, in order to obtain better results. The purpose of this work is to reduce the estimation errors for a pilot hydropower plant, incorporating precipitation data into the forecast. Therefore, an exhaustive research to acquire data from hydrometeorological stations was conducted. After being treated, a variable selection method was applied to the data, defining the most relevant input variables for the prediction model. At the end, a comparative analysis shows that the fuzzy model presents a better performance than the periodic autoregressive model used by ONS to plan the operation of the electric power system.
213

Resposta dinâmica dos reatores UASB (Upflow Anaerobic Sludge Blanket) submetidos a cargas orgânicas e hidráulicas cíclicas: modelação matemática simplificada / Dynamic behavior of the UASB (Upflow Anaerobic Sludge Blanket) reactors submitted to organic and hydraulic cyclical loads: mathematical modeling simplified

Carvalho, Karina Querne de 10 June 2002 (has links)
Em países com condições ambientais, sócio-culturais e econômicas favoráveis à aplicação de processos anaeróbios para tratamento de esgotos sanitários, o reator UASB (Upflow Anaerobic Sludge Blanket) possui muitas vantagens, dentre os reatores anaeróbios, por permitir instalação, operação e manutenção a baixos custos, apresentar baixa geração de lodo, ser capaz de suportar sobrecargas hidráulicas e orgânicas e possuir eficiência de remoção de demanda química de oxigênio entre 70% e 80%. Contudo poucos estudos são reportados na literatura quando o reator é submetido a variações cíclicas diárias, de cargas orgânicas e hidráulicas, em períodos curtos de duração - iguais ou menores que 24 h. Para compreender os prováveis amortecimentos e atrasos nas respostas de reatores UASB quando submetidos a essas variações, desenvolveu-se um modelo matemático simplificado baseado no regime de escoamento contínuo de um tanque de mistura completa, no modelo cinético tipo Monod para remoção de DQO (Demanda Química de Oxigênio) e equacionamentos empíricos reportados na literatura. Esse modelo indicou que, mesmo apresentando baixa eficiência na remoção de demanda química de oxigênio, o reator possui capacidade de amortecer as variações impostas de vazão e respondeu com grande sensibilidade à variação de velocidade específica máxima de degradação de substrato, indicando que esse parâmetro cinético deve ser o parâmetro de calibração do modelo matemático. / In countries with favorable environmental, social, cultural and economical conditions, the use of anaerobic processes in treatment of domestic sewage. The UASB reactor (Upflow Anaerobic Sludge Blanket) has many advantages, among the anaerobic reactors, allows the installation, operation and maintenance with low costs; presents low sludge generation; is capable to support organic and hydraulic overloads and has COD removal efficiencies between 70% and 80%. However few studies are reported in the literature about reactors submitted to cyclical daily variations of organic and hydraulic loads in short periods of time - equal to or shorter than 24 hours. Aiming to understand the probable dampening and the delays in the response of the UASB reactors when submitted to these variations, it was developed a simplified mathematical model based on the continuous flow pattern of a completed stirred tank and in the Monod kinetic model for COD (Chemical Oxygen Demand) removal and empirical kinetic equations reported in the literature. The model indicated that, even when presenting low efficiency in the removal of COD, the reactor has a capacity to dampen the forced flow variations, and responded with great sensivity to the variation of qmáx., indicating that this kinetic parameter may be the calibration parameter of the mathematical model.
214

Resposta dinâmica de reator UASB em escala piloto submetido a cargas orgânicas e hidráulicas cíclicas: modelos matemáticos e resultados experimentais / Dynamic response of a UASB reactor submitted to organic and hydraulic cyclical loads: mathematical models and experimental results

Carvalho, Karina Querne de 14 December 2006 (has links)
Poucos estudos são reportados na literatura sobre o comportamento dinâmico do reator UASB submetido a variações cíclicas diárias, de cargas orgânicas e hidráulicas, em períodos curtos de duração - iguais ou menores que 24h, com os quais verifica-se queda na eficiência do reator, causada pela provável flotação dos grânulos, problemas com geração de odor e alta concentração de sólidos suspensos no efluente. Para melhor compreender a resposta dinâmica desses reatores submetidos a essas variações, foi desenvolvido o modelo MMS baseado no modelo hidrodinâmico de mistura completa em reatores em série, modelo cinético de primeira ordem para consumo de substrato e para crescimento da biomassa e equacionamentos empíricos reportados na literatura. Esse modelo indicou a capacidade do reator de amortecer as variações impostas e a influência da cinética na eficiência de remoção da matéria orgânica. Para calibrar e validar o MMS, foi avaliado o desempenho de um reator UASB (160 L) no tratamento de esgoto sanitário municipal da cidade de São Carlos. Durante o período de operação, o reator foi submetido a variações senoidais cíclicas, de cargas orgânica e hidráulica, em valores inferiores e superiores a 40% e 60% da vazão afluente de 16,0 L/h. A produção média de gás metano e a eficiência média de remoção de DQO alcançadas pelo reator foram de aproximadamente: 1,83 L/h e 61% para vazão afluente de 16 L/h, TDH de 10 h e velocidade ascensional de 0,23 m/h; 2,24 L/h e 48% para variação cíclica de 40% e 2,97 L/h e 40% para variação cíclica de 60%. O MMS indicou faixa de valores para a DQO efluente com diferença em relação aos resultados observados experimentalmente - de 37% para vazão afluente constante de 16 L/h e 59% e 56% para variações senoidais cíclicas de 40% e 60% da vazão afluente, respectivamente – devido à limitação do modelo em considerar o arraste de sólidos no efluente que ocorreu ao longo de toda a operação do reator e mais acentuadamente quando foram aplicadas variações da vazão afluente. O modelo ADM1 proposto por Batstone et al.(2002a,b)apresentou menor similaridade com os resultados observados experimentalmente por não contemplar a variação horária e diária de alguns parâmetros de entrada, mas apenas a média aritmética dos valores. / There are no extensive reports on the dynamic behaviour of UASB reactor submitted to cyclical daily variations of organic and hydraulic loads of short periods of time - equal to or shorter than 24 hours - that can damage the reactor efficiency due to probable granule flotation, odor generation and high concentration of suspended solids in the effluent. Aiming to understand the dynamic response of these reactors when submitted to these variations, it was developed the MMS model based on the N-continuous flow stirred tank reactors (CSTR) in series model, first order kinetics model for substrate consumption and biomass growth and empirical equations reported in the literature. The model indicated the reactor capacity on dampening the imposed flow rate variations and the influence of the kinetics in the organic matter removal efficiency. It was evaluated the response of a UASB in bench scale (160 L) treating sanitary sewage of São Carlos city in order to calibrate and validate the MMS. During the operation, the reactor was submitted to cyclical sinusoidal variations of organic and hydraulic loads in lesser and higher values of 40% and 60% of the influent flow rate of 16 L/h. The reactor achieved mean methane production and mean COD removal efficiency of: 1,83 L/h and 61% to influent flow rate of 16 L/h, HRT of 10 h and upflow velocity of 0,23 m/h; 2,24 L/h and 48% to sinusoidal variation of 40%; 2,97 L/h and 40% to sinusoidal variation of 60%. The MMS model results indicated a range of effluent COD values with a difference of 37% to influent flow rate of 16 L/h, 59% and 56% to sinusoidal variations of 40% and 60%, respectively, in comparison with the experimental observed data. This probably occurred due to the model limitation in considering and predicting the solids washout in the effluent that was verified during all the operation, and also more significant when the sinusoidal variations were applied. The ADM1 reported by Batstone et al. (2002a,b) presented lesser similarity with the experimental observed results due to the fact that it does not consider hourly and daily variations of some input parameters, but only the arithmetical mean of the values.
215

Estimativa de cheias aplicando a técnica de hidrograma unitário com diferentes abordagens de discretização espacial em uma sub-bacia do arroio Pelotas / Flood estimation applying the unit hydrograph technique based on different spatial discretization approaches in a subwatershed of the Pelotas river

Steinmetz, Alice Alonzo, Steinmetz, Alice Alonzo 06 March 2017 (has links)
Submitted by Aline Batista (alinehb.ufpel@gmail.com) on 2017-08-16T14:08:03Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Alice_Alonzo_Steinmetz_Estimativa_de_cheias_aplicando_a_técnica_de_hidrograma_unitário_com_diferentes_abordagens_de_discretização_espacial.pdf: 7122282 bytes, checksum: aef191b90c4f1b064f63c6126e7c0c2f (MD5) / Made available in DSpace on 2017-08-16T14:08:03Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Alice_Alonzo_Steinmetz_Estimativa_de_cheias_aplicando_a_técnica_de_hidrograma_unitário_com_diferentes_abordagens_de_discretização_espacial.pdf: 7122282 bytes, checksum: aef191b90c4f1b064f63c6126e7c0c2f (MD5) Previous issue date: 2017-03-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / A indispensabilidade de preservação dos recursos hídricos estimula os pesquisadores a procurarem uma melhor compreensão quantitativa do ciclo hidrológico. A escassez de monitoramento hidrológico, confrontada com as grandes dimensões das bacias hidrográficas do Brasil, inviabilizam a mensuração da vazão em bacias de pequeno porte, bem como a análise de seu comportamento ao longo de um curso d’água. No tocante à gestão de cheias em bacias hidrográficas, as séries históricas de vazão são fundamentais para entender a resposta da bacia hidrográfica à ocorrência de eventos de chuvas intensas. A necessidade de dados hidrológicos repercute no desenvolvimento de modelos capazes de estimar hidrogramas de escoamento superficial direto (ESD), elemento de maior relevância para a análise de vazões resultantes de eventos extremos de precipitação. Dentre as técnicas de modelagem do ESD, destacam-se a teoria do Hidrograma Unitário (HU) e do Hidrograma Unitário Instantâneo (HUI). O objetivo principal deste trabalho foi avaliar a aplicabilidade e limitações de modelos de HU sintéticos tradicionalmente empregados na engenharia hidrológica (Triangular-HUT e Adimensional-HUA), além de modelos de HUI conceituais (Nash-HUIN e Clark-HUIC) e de suas versões geomorfológicas (Nash-HUIGN e Clark-HUIGC). Todos os procedimentos relacionados aos modelos de HU e HUI foram conduzidos considerando dois cenários de estudo: modelagem concentrada (cenário 1) e modelagem distribuída (cenário 2). A área de estudo foi a bacia hidrográfica do arroio Cadeia que é uma importante sub-bacia da bacia hidrográfica do arroio Pelotas (BHAP), situada no sul do estado do Rio Grande do Sul. As informações primordiais para a aplicação de tais modelos foram as variáveis topográficas extraídas do modelo digital de elevação e dados temporais de chuva e vazão monitorados na bacia, fazendo uso da rede de monitoramento hidrológico existente na BHAP. Dez eventos chuva-vazão foram analisados e o método do Número da Curva possibilitou estimar a distribuição temporal de precipitações efetivas para ambos os cenários. O processamento computacional constituiu-se da aplicação do software HEC-HMS e da linguagem de programação R para a análise dos modelos de HU e HUI supracitados. Para a calibração dos parâmetros dos modelos, empregou-se o algoritmo Nelder Mead. As principais constatações deste trabalho foram: i) os modelos HUIC e HUIN foram os que tiveram melhor acurácia para estimativa de vazões de pico e dos hidrogramas; ii) as formulações geomorfológicas não são universais e necessitam ser utilizadas com cautela; iii) os modelos ajustados apresentaram desempenho ligeiramente superior quando discretizado por sub-bacia; iv) os modelos que utilizam parâmetros geomorfológicos possuíram melhor desempenho quando aplicada a modelagem concentrada; v) o algoritmo Nelder Mead pode ter aplicação limitada; vi) outros algoritmos devem ser investigados em estudos futuros no intuito de buscar soluções mais adequadas; vii) no cenário 2 foi possível discretizar os parâmetros e relacionar com a realidade hidrológica da bacia em estudo. / The indispensability of preserving water resources encourages researchers to seek a better quantitative understanding of the hydrological cycle. The scarcity of hydrological monitoring in conjunction with the large dimensions of Brazilian watersheds makes it unfeasible to measure stream flow and to analyze its behavior along a watercourse in small-sized watersheds. With regard to flood management in watersheds, historical stream flow series are fundamental to understand the watershed response to the occurrence of heavy rainfall events. The need for hydrological data stimulates the development of models capable of estimating direct surface runoff (DSR) hydrographs, which is the most relevant component when analyzing stream flows originated from extreme rainfall events. Among the techniques available for DSR modeling, the theory of Unit Hydrograph (UH) and Instantaneous Unit Hydrograph (IUH) should be highlighted. The main objective of this study was to evaluate the applicability and limitations of synthetic UH models traditionally used in hydrological engineering (Triangular-TUH and Dimensionless-DUH), conceptual IUH models (Nash-NIUH and Clark-CIUH) and their geomorphological versions (Nash-GNIUH and Clark-GCIUH). All the procedures involving UH and IUH models were carried out taking into account two study scenarios: lumped modeling (scenario 1) and distributed modeling (scenario 2). The study area was the Cadeia river watershed, which is an important subwatershed of the Pelotas river watershed (PRW), located in the south of Rio Grande do Sul State. The main information for the application of such models were topographical variables extracted from digital elevation model and temporal series related to rainfall and stream flow monitored in the watershed, making use of the existing hydrological monitoring network in the PRW. Ten rainfall-runoff events were evaluated and the Curve Number method was used to estimate the temporal distribution of effective rainfalls for both scenarios. The computational processing consisted of the application of both HEC-HMS software and R programming language for analysis of the aforementioned UH and IUH models. Nelder Mead algorithm was employed for calibration of the models’ parameters. The main findings of this study were: i) CIUH and NIUH were the models that had the best accuracy for estimation of peak stream flows and hydrographs; ii) the geomorphological formulations are not universal and need to be used carefully; iii) the adjusted models resulted in slightly superior performance when discretized by sub-basin; iv) the models dependent on geomorphological parameters had better performance when lumped modeling was applied; v) the Nelder Mead algorithm may have limited application; vi) other algorithms should be investigated in future studies in order to seek more adequate solutions; vii) in scenario 2, it was possible to discretize the parameters and relate them to the hydrological reality of the watershed under analysis.
216

Avaliação de Correlações e Equações de Estado para Determinação de Fatores de Compressibilidade de Gás Natural / Compressibility factors for natural gases by correlations and equations of state

Edilso Macedo Lopes Borges 29 December 2009 (has links)
O fator de compressibilidade (Z) de gás natural é utilizado em vários cálculos na engenharia de petróleo (avaliação de formações, perda de carga em tubulações, gradiente de pressão em poços de gás, cálculos de balanço de massa, medição de gás, compressão e processamento de gás). As fontes mais comuns de valores de Z são medições experimentais, caras e demoradas. Essa propriedade também é estimada por correlações empíricas, modelos baseados no princípio dos estados correspondentes ou equações de estado (EOS). Foram avaliadas as capacidades das EOS de Soave-Redlich-Kwong (SRK), Peng-Robinson (PR), Patel-Teja (PT), Patel-Teja-Valderrama (PTV), Schmidt-Wenzel (SW), Lawal-Lake-Silberberg (LLS) e AGA-8 para previsão desta propriedade em aproximadamente 2200 pontos de dados experimentais. Estes pontos foram divididos em quatro grupos: Grupo 1 (Presença de frações C7+, Grupo 2 (temperaturas inferiores a 258,15 K), Grupo 3 (pressões superiores a 10000 kPa) e Grupo 4 (pressões inferiores a 10000 kPa). Os cálculos utilizando as equações de estado sob diferentes esquemas de previsão de coeficientes binários de interação foram cuidadosamente investigados. Os resultados sugerem que a EOS AGA-8 apresenta os menores erros para pressões de até 70000 kPa. Entretanto, observou-se uma tendência de aumento nos desvios médios absolutos em função das concentrações de CO2 e H2S. As EOS PTV e a EOS SW são capazes de predizer o fator de compressibilidade (Z) com desvios médios absolutos entre os valores calculados e experimentais com precisão satisfatória para a maioria das aplicações, para uma variada faixa de temperatura e pressão. Este estudo também apresenta uma avaliação de 224 métodos de cálculo de Z onde foram utilizadas 8 correlações combinadas com 4 regras de mistura para estimativa de temperaturas e pressões pseudorreduzidas das amostras, junto com 7 métodos de caracterização das propriedades críticas da fração C7+, quando presente na composição do gás. Em função dos resultados são sugeridas, para diferentes tipos de sistemas, as melhores combinações de correlações com regras de mistura capazes de predizer fatores de compressibilidade (Z) com os menores erros absolutos médios relativos / The compressibility factor (Z-factor) of natural gases is necessary in many petroleum engineering calculations (evaluation of formation, pressure drop through a pipe, pressure gradient in gas wells, material balance calculations, gas metering, gas compression and processing). The most common sources of Z-factor values are experimental measurements, which are expensive and time consuming. This property is also estimated from empirical correlations, corresponding state models or equations of state (EOS) when experimental data is unavailable. Capabilities of Soave-Redlich-Kwong (SRK), Peng-Robinson (PR), Patel-Teja (PT), Patel-Teja-Valderrama (PTV), Schmidt-Wenzel (SW), Lawal-Lake-Silberberg (LLS) and AGA-8 to predict this property of 2200 data points under various schemes of binary interaction numbers are thoroughly investigated. This database was split on four groups: Group 1 (presence of hydrocarbon plus fraction - C7+), Group 2 (temperatures lower than 258.15 K), Group 3 (pressures higher than 10000 kPa) e Group 4 (pressures lower than 10000 kPa). The best results were obtained from EOS AGA-8 for pressures up to 70000 kPa. However, an increasing trend in average absolute deviations was observed as a function of CO2 e H2S concentrations. EOS PTV and EOS SW are capable to predict the compressibility factor (Z) with average absolute deviation between calculated and experimental values with satisfactory accuracy for most applications for a wide range of temperature and pressure. This study also presents an evaluation of 224 possible methods of calculating the gas compressibility factor, based on 8 correlations and corresponding state models, combined with 4 mixing rule that predict the pseudo-reduced pressure and temperatures of the mixture, that were combined with 7 methods of characterizing the plus fraction critical properties when present in the gas composition. Results suggest for different systems conditions, the best correlation and mixing rule combination capable of predicting Z-factor with the least average absolute relative error
217

Simulaçõeses numéricas de efeitos de acidentes de linha causados por curvas à montante de medidores de vazão por ultrassom de um canal por tempo de trânsito para gás de flare / Numerical simulations of installation effects caused by upstream elbows on single-path transit-time ultrasonic flare flow meters

Martins, Ramon Silva 23 May 2012 (has links)
Made available in DSpace on 2016-12-23T14:08:08Z (GMT). No. of bitstreams: 1 Martins RS Part 1.pdf: 212782 bytes, checksum: 40ca14a4b97179f5b3af71f964306b97 (MD5) Previous issue date: 2012-05-23 / Oil and gas industry requires accurate flow measurements since they are stated by law. Nevertheless, curves and other obstacles are commonly found in such industry field, which may affect the quality of flow measurement due to flow disturbances, such as swirl and velocity profile asymmetries. Single-path ultrasonic flow meters are often used in flare gas installations, despite being sensitive to such disturbances. The present work use commercial CFD codes to obtain disturbed flow fields downstream from single and double elbow pipe installations, aiming to investigate both magnitude and behaviour of such effects on ultrasonic flow measurement. Numerical integration is applied for several acoustic path arrangements, simulating single-path ultrasonic flow meters in different situations in order to evaluate its correction factor deviation under disturbed conditions. Reynolds numbers from 1X10 4 to 2 X10 6 are considered. Transducers mounting angles from 0° to 180° are tested and axial positions up to 80D downstream from the curve are evaluated. Results indicate that single-path ultrasonic flow meters are sensitive to installation effects. Correction factor deviations usually showed to be significantly higher than 2% for axial positions shorter than 20D, as recommended by several manufacturers or regulations. Nevertheless, deviations may reach 0.01% in some specific configurations, which suggests that ultrasonic flow measurement might be improved by rearranging flow meter device in favourable angular position and mainly by implementation of specific functions for correction factors under disturbed conditions / A indústria de petróleo e gás requer medições de vazão de baixa incerteza, uma vez que são estabelecidas por lei. Contudo, curvas e outros obstáculos são comumente encontrados nesse cenário e podem afetar a qualidade da medição de vazão em função de perturbações no escoamento, tais como swirl e assimetrias no perfil de velocidades. Medidores de vazão por ultrassom de um canal são frequentemente utilizados em instalações de gás de queimadores, apesar de serem sensíveis a tais perturbações. O presente trabalho usa códigos comerciais de CFD para obter o escoamento à jusante de instalações com uma curva e duas curvas, visando a investigar a magnitude e o comportamento de tais efeitos na medição de vazão. Integração numérica é utilizada para diversos arranjos de caminho acústico, simulando medidores de vazão por ultrassom de um canal em várias condições para avaliar o desvio do fator de correção em escoamentos perturbados. Números de Reynolds de 1×10 4 a 2×10 6 são considerados. Ângulos de montagem dos transdutores de 0° a 180° são testados e posições axiais até 80D à jusante do obstáculo são avaliadas. Os resultados indicam que medidores de vazão por ultrassom são sensíveis aos efeitos de acidente de linha. O desvio do fator de correção mostra-se, em geral, consideravelmente maior que 2% em distâncias menores que 20D, conforme recomendado por alguns fabricantes e por leis. Não obstante, tais desvios podem atingir 0,01% em algumas configurações específicas, o que sugere que a medição de vazão por ultrassom pode ser melhorada pelo rearranjo do aparato em posição angular favorável e, principalmente, pela implementação de funções específicas para fatores de correção em condições perturbadas
218

Análise experimental sobre a utilização de sensores infravermelhos em provadores de vazão de fluidos claros

Barone, Marcelo Aiolfi 29 October 2012 (has links)
Made available in DSpace on 2016-12-23T14:08:10Z (GMT). No. of bitstreams: 1 Marcelo Aiolfi Barone - cap 00 - 01 - 02 - 03 - 04.pdf: 1483841 bytes, checksum: f4e05e25d485e179dfceea82acfc06b7 (MD5) Previous issue date: 2012-10-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho utiliza um protótipo de escala laboratorial do medidor primário pipe prover de modo a avaliar a sua conformidade com os requisitos estabelecidos por normas técnicas e examinar a incerteza da medição da vazão realizados, além de verificar a reprodutibilidade das medições, testes com esferas de diferentes diâmetros, a influência de parâmetros operacionais tais como a variação da pressão de operação e comparação com o teste gravimétrico. O protótipo é feito de tubos plástico com dimensões definidas estatisticamente. Dentro do tubo, uma esfera de elastômero interferente é impulsionada por um escoamento fornecido por uma bomba centrífuga. O sistema de detecção usa sensores de luz infravermelha capaz de detectar a passagem das esferas sem causar interferência ou bloqueio na tubulação. O sistema de aquisição de dados é automático e registra o tempo de trânsito da esfera através de cada pulso de sinal detectado bem como os pulsos gerados por um medidor calibrado tipo turbina, como comparação da avaliação das incertezas de processo utilizando o desempenho da técnica dos sensores infravermelhos / The work uses a laboratory scaled prototype of primary pipe prover flowmeter in order to assess conformity with the requirements established by technical standards and examine the uncertainties of flow measurement performed, besides to check the reproducibility of measurements, tests with spheres of different diameters, the influence of operating parameters such as operating pressure variation and comparison with gravimetric test. The prototype is plastic tubing and considering statically defined dimensions. Inside tubing, an interfering elastomer sphere is driven by flow provided by a centrifugal pump. The detection system uses infrared light sensors able to detect the spheres passage causing pipeline interference or blockage. The acquisition data system is automatic and records the sphere transit time through each pulse signal detected as well as the pulses generated by a calibrated turbine meter, as comparison of the evaluation of process uncertainties using the technique performance with infrared sensors
219

Variabilidade espaço-temporal da precipitação e vazão e suas consequências para a gestão dos recursos hídricos regionais / Spatial-temporal variability of precipitation and flow and its consequences for the management of regional water resources

Silva, Danilo José Brandão Vitor [UNESP] 19 January 2017 (has links)
Submitted by Danilo José Brandao Vitor Silva null (danilojbrandao@yahoo.com.br) on 2017-02-03T15:40:19Z No. of bitstreams: 1 TESE DANILO BRANDÃO.pdf: 1732370 bytes, checksum: 2cb226321b60bf10a72d6f5d86091dfb (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-02-07T11:31:33Z (GMT) No. of bitstreams: 1 silva_djbv_dr_guara.pdf: 1732370 bytes, checksum: 2cb226321b60bf10a72d6f5d86091dfb (MD5) / Made available in DSpace on 2017-02-07T11:31:33Z (GMT). No. of bitstreams: 1 silva_djbv_dr_guara.pdf: 1732370 bytes, checksum: 2cb226321b60bf10a72d6f5d86091dfb (MD5) Previous issue date: 2017-01-19 / Este trabalho analisou os parâmetros hidroclimatológicos, buscando encontrar o padrão de precipitação em uma abordagem espaço-temporal para a porção paulista da bacia do rio Paraíba do Sul, empregando o interpolador geoestatístico krigagem. Além disso, verificou a existência de tendência de precipitação e de vazão em séries históricas nesta mesma bacia, utilizando o teste estatístico de Mann-Kendall. Com relação a espacialização da precipitação, foi constatada uma significativa variação espacial para os períodos analisados (verão, outono, inverno e primavera). No verão, período de recarga dos reservatórios, foram registrados os menores índices de precipitação na área de contribuição das sub-bacias que abastecem os reservatórios do Paraibuna e do Jaguari, implicando em uma possível redução na vazão afluente. Não se constatou tendência de precipitação estatisticamente significativa em escala de tempo interanual para os postos pluviométricos, entretanto, foi identificada tendência de diminuição para o outono. Para os postos fluviométricos das sub-bacias do rio Paraibuna, do rio Paraitinga e do rio Jaguari-Buquira, em um período interanual, houve tendência de aumento de vazão para séries históricas de 1930 a 1970 e de diminuição para séries de 1930 a 2015. As estações de medição de vazão utilizadas foram aquelas localizadas a montante dos reservatórios, não estando submetidas assim ao efeito de regularização de vazão. A tendência de diminuição de vazão encontrada para a região pode levar a uma alteração na disponibilidade hídrica e a um possível impacto no abastecimento e na geração de energia. / This research analyzed the hydroclimatological parameters, seeking to find the precipitation pattern in a space-time approach for the São Paulo portion of the Paraíba do Sul river basin, using the geostatistical interpolator kriging. In addition, it verified the existence of precipitation and streamflow trends in historical series for the same basin, using the statistical test of Mann-Kendall. Regarding the precipitation pattern, a significant spatial variability was observed for the periods analyzed (summer, autumn, winter and spring). In the summer, reservoir recharge period, the lowest precipitation rates were recorded in the sub-basin contribution area that supply the Paraibuna and Jaguari reservoirs, implying a possible reduction in the inflow. There was no statistically significant precipitation trend in the interannual time scale for the pluviometric stations, however, a decrease trend was identified for the autumn. For fluviometric stations in the sub-basins of the Paraibuna, Paraitinga and Jaguari-Buquira rivers, in the interannual time scale, there was a trend towards an increase in streamflow for historical series from 1930 to 1970 and decrease for series from 1930 to 2015. The streamflow stations used were those located upstream of the reservoirs and were not subject to the effect of flow regulation. The downward trend in streamflow found in the region can lead to a change in water availability and a possible impact on the supply and energy generation.
220

Amortecimento superficial nos sistemas de micro-drenagem em regiões de baixa declividade. / Peak flow reduction for micro-drainagem systems applied to flat areas.

Atila Csobi 20 April 2011 (has links)
O presente trabalho desenvolve uma proposta para a avaliação da redução da vazão de pico do hidrograma do método racional, no contexto de bacias hidrográficas topograficamente planas. Entendem-se como planas aquelas localidades, cujas declividades médias características e/ou projetadas são inferiores a 0,5%. Pretende-se também neste trabalho apresentar metodologias e práticas de projeto de drenagem usualmente adotadas em regiões de características topográficas semelhantes. No desenvolvimento do estudo, foram discutidas as bases teóricas do Método Racional e outros métodos de avaliação hidrológica que procuram levar em conta o amortecimento da vazão durante o seu escoamento sobre o leito das vias. Apresentam-se também as bases científicas para a criação de um modelo hidrodinâmico a ser usado no estudo para a determinação do fator de redução da vazão de pico do hidrograma racional. A capacidade de escoamento em vias urbanas é então discutida, de forma a se justificar as relações criadas como conclusão do trabalho. O resultado final apresentado é o estabelecimento de uma relação entre a variação do pico da vazão do Método Racional, com a capacidade de armazenamento ou amortecimento de cheias existente nessas vias. Relações estas que, para fins práticos, significam tanto o incremento positivo no período de retorno do projeto, quanto a redução da vazão para efeito de dimensionamento de galerias. Tais resultados são demonstrados de forma prática por meio do estudo de caso no município de Praia Grande, o litoral sul paulista. / This work presents a proposal for estimating the reduction of the Peak Flow Rate determined by the Rational Method, considering flat basins as a main characteristic. It is considered flat, all of those basins in which the average slope on the streets are smaller than 0,5 %. It is also intentions of this work discuss methods and practices adopted to flat areas as urban drainage solutions and best management practices. Within this work, we also present all the theoretical basis of the Rational Method, among others, that try to fuse the street storm water storage capacity whit the conveyance capacity of a usual street. It is also presented theoretical basis of hydrodynamic models to be used as the main tool to determine de peak flow reduction factor of the Rational Method Hydrogram. Conveyance capacity of a usual street is discussed, street storm water conveyance capacity is also discussed in order to justify the relations proposed as a conclusion of this work. As a result of this work it is established a relationship between the Peak flow rate determined by the Rational Method and the street storm water storage capacity. In addition, this peak reduction can be used as a positive increment on the Recurrence Interval or as flow rate reduction when designing the sewerage system, which means implementation costs reduction. An application to the city of Praia Grande, located the Sao Paulo State, is presented and used as a case of study.

Page generated in 0.0631 seconds