• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 14
  • 14
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dessaturação em teste incremental de caminhada / Desaturation in healthy subjects after the shuttle walk test

Seixas, Daniel Machado, 1980- 24 August 2018 (has links)
Orientador: Ilma Aparecida Paschoal / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T07:53:53Z (GMT). No. of bitstreams: 1 Seixas_DanielMachado_M.pdf: 1848962 bytes, checksum: 80ebf21f0114a4503b21846263f7ad6d (MD5) Previous issue date: 2012 / Resumo: O "Shuttle Walking Test" (SWT), padronizado na literatura como um teste de esforço submáximo e utilizado em pacientes com DPOC (Doença Pulmonar Obstrutiva Crônica), foi aplicado em indivíduos saudáveis para verificar se a dessaturação, após a realização deste teste, é um evento provável. Foram selecionados indivíduos saudáveis, praticantes de atividade física pelo menos 2 vezes por semana em academia de ginastica. Os indivíduos que tivessem antecedentes de doenças pulmonares e/ou cardíacas ou qualquer outra condição de saúde que impossibilitassem a realização do teste foram excluídos do estudo. Os valores de fluxo expiratório do primeiro segundo e do sexto segundo (VEF1 e VEF6) foram determinados antes da realização dos testes através de um medidor digital de pico de fluxo (Peck Flow). Outros parâmetros avaliados antes do SWT foram frequência cardíaca basal e saturação de oxigênio inicial. Logo após o final do teste foram verificados os mesmos parâmetros do início do teste. A versão do SWT utilizada neste trabalho foi a modificada, com 12 níveis de intensidade. Oitenta e três indivíduos (55 homens) foram selecionados (apenas um fumante). A idade média foi 35,05 ± 12,53. O índice de massa corporal (IMC) foi de 24,30 ± 3,47. A média de frequência cardíaca de repouso foi de 75,12 ± 12,48. A média da saturação periférica de O2 (SpO2) em repouso foi 97,96% ± 1,02%. A média do VEF1 foi de 3,75 ± 0,81 L; a média de VEF6 foi de 4,45 ± 0,87 L. A média VEF1/VEF6 foi de 0,83 ± 0,08 (sem restrição e / ou obstrução). A média de distância percorrida foi 958,30 ± 146.32m. A média da frequência cardíaca após SWT foi 162,41 ± 18,24. A média da SpO2 final foi 96,27% ± 2,21%. Onze indivíduos apresentaram maiores valores de SpO2 final; 17 indivíduos tiveram quedas na SpO2 final, igual ou superior a 4 pontos. A comparação entre os grupos, com e sem dessaturação, não mostraram diferenças em idade, sexo, VEF1, VEF6, VEF1/VEF6, saturação inicial, distância caminhada, frequência cardíaca e percentual da frequência cardíaca máxima. O IMC foi maior naqueles que dessaturaram (p = 0,01) e SpO2 final foi menor (p <0,0001). Estes resultados permitem concluir que pessoas saudáveis podem dessaturar após SWT e desta forma, a utilização do SWT para predição de doenças respiratórias leves pode não ser adequada. Dessaturação é comum em indivíduos saudáveis após o SWT, como na atividade física intensa, e pode ter efeitos deletérios. / Abstract: Aim. To perform the shuttle walk test in healthy individuals to determine if desaturation at the end of the test is a probable finding. Healthy subjects were enrolled. Antecedents of pulmonary and/or cardiac diseases or any other health condition were exclusion criteria. FEV1 and FEV6 were determined before the SWT (digital peak flow meter). Baseline heart rate and oxygen saturation were determined with a pulse oxymeter. The SWT was the 12-level version. Saturation was measured after the SWT. Results. 83 subjects (55men) were enrolled (one smoker). Mean age was 35.05±12.53. Mean body mass index (BMI) was 24.30±3.47. Mean rest heart rate was 75.12±12.48. Mean rest SpO2 was 97.96%±1.02%. Mean FEV1 was 3.75±0.81 L; mean FEV6 was 4.45±0.87 L. Mean FEV1/FEV6 was 0.83±0.08 (no restriction and/or obstruction). Mean walk distance was 958.30±146.32m. Mean heart after SWT was 162.41±18.24. Mean final SpO2 was 96.27%±2.21%. Eleven subjects had greater values of final SpO2; 17 subjects had falls in final SpO2 ? 4 points. The comparison between the groups with and without desaturation showed no differences in age, sex, FEV1, FEV6, FEV1/FEV6, initial saturation, walk distance, heart rate and percentage of maximum heart rate. BMI was higher in those who desaturate (p=0.01) and final SpO2 was smaller (p<0.0001). Conclusion. Healthy people may desaturate after SWT; its use to predict the presence of subtle respiratory disorders, may be misleading. Desaturation is common in healthy subjects after the SWT as in intense physical activity and may have deleterious effects. / Mestrado / Clinica Medica / Mestre em Clinica Medica
2

Samband mellan gångsträcka, dyspné och desaturation i 6 minuters gångtest hos en grupp individer med pulmonell arteriell hypertension (PAH) - en registerbaserad pilotstudie.

Hedin, Kajsa January 2020 (has links)
Background: Pulmonary arterial hypertension (PAH) is a rare but serious disease with symptoms as dyspnea, fatigue and intolerance to exercise. The treatment is mainly pharmacological with physical exercise as an important complement. The 6 minutes walking test (6MWT) is used today worldwide for assessment and follow-up of the PAH patient. Objective: The aim of this study was to, among a PAH-population in Norrland, examine the 6-minutes walking test variables walking distance, ∆dyspnea and Δsaturation according to change over time and correlation between the variables. A further objectice was to examine any differences between four different PAH risk groups according to ∆dyspné och Δsat. Method:  This study is a retrospective register study based on the Umeå/Sundsvall part of the Swedish patient registry SPAHR. A total of 69 patients were examined at the time of diagnosis and at follow-up after 12 ± 3 months regarding 6MWT. Results: A significantly longer walkning distance was measured at follow-up comepared to baseline (284 m (IQR 187-410) vs 322 m (IQR 240 - 435), p &lt; 0,001). A negative but weak correlation existed  at baseline between walking distance and Δsat (r = -0.23, p= 0.022) and at follow-up (r = -0.27, p= 0.033). No significant difference regarding Δsaturation and Δdyspnea could be seen between the risk groups.  Conclusion: Also this study demonstrates that the walking distance is the measure that is seen to vary over time, while Δsaturation and Δdyspnea have not been shown to do so. The weak correlation that could be detected between walking distance and Δsaturation raises the idea that it may be a factor that strengthens or weakens the result measured in meters and could thus possibly increase the informational value of the 6MWT. However, the results of this study indicate that desaturation and estimated dyspnea are not factors that correlate with the walking distance (and thus the patient's functional working capacity). Other variables such as quality of life and fear of movement may need to be estimated by the patient group to be able to evaluate and plan both pharmacological treatment and physical exercise, and to see if it can predict the outcome of the treatment. This should be studied scientifically.
3

Sambandet mellan undersökningsinstrument för fysisk aktivitet som används för barn med övervikt

Blomqvist, Linnea January 2012 (has links)
Sammanfattning Att undersöka en befolknings fysiska aktivitet ger beskrivande data utav dagsläget samt att resultatet fungerar som mätinstrument för hur en framtida intervention ska utformas. Syftet med denna studie var att se om något samband förelåg mellan tre olika undersökningsinstrument för fysisk aktivitet, som används för med barn med övervikt. Metod: Deltagarna mättes, vägdes, skattade sin fysiska aktivitetsnivå (frågeformulär), testade sin fysiska prestationsförmåga (sex minuters gångtest) och deras fysiska aktivitet mättes (accelerometer). Resultat: Åtta flickor, 7-13 år, med ett Body Mass Index (BMI) på 26 ± 3,7 kg/m2deltog. Majoriteten skattade sig vara fysiskt aktiva 30-60 min/dag under vardag och helg, men som grupp var skattningen signifikant lägre på helgen. Deltagarnas fysiska prestationsförmåga var signifikant lägre än det beräknade normalvärde. Barnen utförde i snitt 67 ±24 min/dag aktivitet under vardagarna och signifikant mindre aktivitet (31 ± 29,7min/dag) på helgerna. Ett signifikant samband förelåg mellan undersökningsinstrumenten för utförd fysisk aktivet under vardagarna och prestationsförmågan, där även en formel för hur sambandet kunde kalkyleras framtogs. Slutsats: Trots litet deltagarantal skulle studiens resultat tyda på att 6MGT kan användas inte bara för att bedöma prestationsförmåga utan även för beräknad utförd fysisk aktivitet under vardagarna. / Abstract Investigation physical activity in a population gives descriptive data and the result serves as a measuring instrument for how future interventions ought to be designed. The purpose of this study was to see whether any associations existed between three examination instruments for physical activity that are used with children with overweight. Method: The participants were measured, weighed, estimated their physical activity (questionnaire), testing their physical performance (six-minute walking test) and their physical activity was measured (accelerometer). Results: Eight girls, aged 7-13, body mass index of 26 ± 3.7, participated. The majority of the children estimated to be physically active for 30-60 min/day, during weekdays and weekends, but seen as a group the estimation was significantly lower on the weekend. Their physical performance showed a significantly lower value than the predicted value. The children performed on average for 67 ± 24 min / day during the week and significantly less (31 ± 29.7 min / day) on weekends. A significant association existed between performed physical activity during weekdays and the performance test. A formula for how this relationship could be calculated was designed. Conclusion: Despite low numbers of participants the result of the study could indicate that 6MWT can be used not only for assessing the performance but also to calculate the executed amount of activity during weekdays.
4

Validação de um protocolo em esteira para pacientes com hipertensão arterial pulmonar / Validation of a walk test protocol for the evaluation of patients with pulmonary arterial hypertension

Camargo, Viviane Moreira de 25 November 2008 (has links)
A hipertensão arterial pulmonar (HAP) é uma doença que acomete o território vascular pulmonar, gerando incapacidade funcional e falência cardíaca progressiva. Diversos marcadores de resposta têm sido desenvolvidos para a avaliação dos pacientes com HAP frente às novas modalidades terapêuticas desenvolvidas nos últimos anos, entre os quais o teste de caminhada de seis minutos é o mais utilizado. Embora seja simples, possui algumas limitações inerentes à técnica padrão, como por exemplo a necessidade de espaço físico adequado para sua realização. O objetivo deste trabalho foi elaborar e validar um protocolo de caminhada na esteira para a avaliação de pacientes com HAP. Os resultados mostraram correlação da distância caminhada em esteira com os dados hemodinâmicos, assim como com a classificação funcional e com a distância caminhada no solo. Além disso, a distância percorrida no teste em esteira apresentou correlação significativa com a sobrevida, confirmando portanto, sua correlação com a gravidade da doença. A inalação de óxido nítrico(NO) durante o teste de caminhada levou a variações compatíveis com as variações hemodinâmicas frente à mesma dose de NO, sugerindo que o protocolo em questão possa refletir intervenções terapêuticas. Conclui-se que o protocolo de caminhada na esteira é um marcador funcional e prognóstico para pacientes com HAP, constituindo-se em um instrumento útil na avaliação de rotina de pacientes com HAP. / Pulmonary arterial hypertension (PAH) is a disease affecting the pulmonary arterial territory leading to progressive functional impairment and heart failure. Many different surrogate markers have been studied to evaluate PAH patients under the different treatment strategies that have been developed during the last decade. Among these markers, the six-minute walk test is the most used one. Although simple, many limitations exist mainly related to the need of appropriate physical area to perform the test properly. The aim of this study was to develop and validate a treadmill six-minute walk test for PAH patients evaluation. The developed protocol well correlated with other markers of disease severity as invasive hemodynamic data, functional class and even the distance walk at the hallway six minute walk test. Furthermore, the treadmill walked distance was associated to survival thus strengthening its ability to reflect disease severity. Nitric oxide (NO) inhalation during the treadmill walk test led to a variation in the walked distance proportional to the hemodynamic changes induced by the same dose of inhaled NO, suggesting that the developed protocol may be able to reflect at least acute therapeutical interventions. We conclude that the treadmill six minute walk test is a useful prognostic and functional marker for the routine evaluation of PAH patients.
5

Associação entre o trabalho de caminhada de seis minutos e a capacidade aeróbia de pico em pacientes com doença pulmonar obstrutiva crônica

Poersch, Karla January 2009 (has links)
O teste de exercício cardiopulmonar incremental (TECP) tem sido utilizado para avaliar o impacto global da doença em pacientes com DPOC. Considerando que as avaliações de exercício em laboratório são demoradas, caras e muitas vezes indisponíveis, o teste de caminhada de seis minutos (TC6min) não exige equipamentos caros e sofisticados, e pode ser facilmente realizado. Embora, a principal medida comumente utilizada no teste de caminhada seja a distância percorrida durante os 6 minutos (D), esta medida não leva em conta as diferenças de peso corpóreo, que podem influenciar o desempenho do exercício. Além disso, estudos anteriores correlacionaram o trabalho realizado durante o TC6min com TECP incremental pedalando, modalidade de exercício comumente associada a fadiga de quadríceps e menor consumo de oxigênio de pico ( O2) do que o TECP caminhando. O principal objetivo desse estudo foi avaliar a correlação entre a distância percorrida no TC6min (D) e o produto distância percorrida - peso corporal (DxP), uma estimativa do trabalho realizado durante o TC6min, com o O2 de pico obtido durante o TECP incremental em esteira ergométrica. Foram estudados trinta pacientes (19 homens), apresentando média (± DP) de idade de 66,3 ± 7,5 anos, com DPOC estável de moderada a grave intensidade (VEF1 médio de 1,1 ± 0,4L e 39 ± 13% predito) que realizaram TECP incremental em esteira ergométrica até o limite máximo de tolerância e o TC6min. Os testes foram realizados com pelo menos 48 horas de intervalo. A correlação de Pearson foi utilizada para avaliar o nível de associação entre o O2 pico, a distância e o trabalho executado durante o TC6min. Os pacientes percorreram 425,1 ± 78,6 m e realizaram um trabalho de 28166,4 ± 8368,4 Kg-m durante o TC6min, enquanto que o O2 de pico atingido foi 965,6 ± 370,1 mL/min (68,7 ± 17,4% do previsto) no TCPE. Ao final do exercício, em ambos os testes, a dispnéia foi a principal queixa e maior percepção de dispnéia e maior frequência cardíaca foi observado ao final do TECP comparativamente ao TC6min. O trabalho da caminhada (DxP) durante o TC6min demonstrou maior correlação com o O2 pico do que a distância (D) isoladamente. O mesmo ocorreu para VEF1, CVF, CI, DLCO, CO2, E e duplo produto (uma estimativa do trabalho do miocárdio), (r = 0,57; r = 0,57; r = 0,73; r = 0,7; r = 0,75; r = 0,65; r = 0,51; r = 0,4 respectivamente, todos com p <0,05). Dessa forma, esse estudo corrobora a melhor associação entre o trabalho estimado a partir da TC6min e o O2 pico atingido durante TECP, neste caso em esteira ergométrica, em comparação à distância isoladamente. / Incremental cardiopulmonary exercise testing (CPET) is increasingly used to evaluate the overall impact of the illness in patients with COPD. Whereas laboratory tests of exercise performance are often time-consuming, costly and frequently unavailable, the six-minute walk test (6MWT) does not require expensive or sophisticated equipments, and can be easily performed. Although, the main outcome measure commonly used in this field test is the distance walked during the predetermined 6 minutes (6MWD), this measure does not account for differences in body weight that are known to influence exercise performance. Furthermore, previous studies correlated the working performed during 6MWT with incremental cycling CPET, an exercise modality more associated with quadriceps fatigability and lower peak oxygen consumption ( O2) than incremental walking tests. The main objective of this study is to evaluate the correlation between 6MWD and its derivative walking distance-body weight product, an estimation of the work performed during 6MWT, with peak O2 obtained during a treadmill incremental CPET. The study enrolled thirty patients (19 males), with a mean (± SD) age of 66.3 ± 7.5 years and a stable moderate-to-severe COPD (ie, mean FEV1 1.1 ± 0.4L and 39 ± 13 % predicted) performed a ramp incremental CPET to the limit of tolerance on a treadmill and 6MWT. Tests were performed at least 48 h apart. Pearson´s correlation was used to assess the level of association between peak O2 and the distance and work executed during 6MWT. The patients walked 425.1 ± 78.6 m and performed a work of 28,166.4 ± 8368.4 (Kg-m) during the 6MWT while achieved a peak O2 of 965.6 ± 370.1 mL/min (68.7 ± 17.4% of predicted) in the treadmill CPET. They mainly stopped exercise due to dyspnea in both tests and reported a greater perception of dyspnea and higher heart rate was observed at the end of the CPET. The work of walking during the 6-MWT (DxW) provided greater and more frequent significant correlation with peak O2 than that observed with 6MWD.This was the case for FEV1, FVC, IC, DLCO, CO2, E, and double product (an estimate of myocardial work) (r=0.57; r=0.57; r=0.73; r=0.7; r=0.75; r=0.65; r=0.51 and r= 0.4, respectively; all p<0.05). This study provides evidence to corroborate the better association between the work estimated from the 6MWT and peak O2 achieved during CPET, in this case with a treadmill, than the 6MWD on isolation.
6

Validação de um protocolo em esteira para pacientes com hipertensão arterial pulmonar / Validation of a walk test protocol for the evaluation of patients with pulmonary arterial hypertension

Viviane Moreira de Camargo 25 November 2008 (has links)
A hipertensão arterial pulmonar (HAP) é uma doença que acomete o território vascular pulmonar, gerando incapacidade funcional e falência cardíaca progressiva. Diversos marcadores de resposta têm sido desenvolvidos para a avaliação dos pacientes com HAP frente às novas modalidades terapêuticas desenvolvidas nos últimos anos, entre os quais o teste de caminhada de seis minutos é o mais utilizado. Embora seja simples, possui algumas limitações inerentes à técnica padrão, como por exemplo a necessidade de espaço físico adequado para sua realização. O objetivo deste trabalho foi elaborar e validar um protocolo de caminhada na esteira para a avaliação de pacientes com HAP. Os resultados mostraram correlação da distância caminhada em esteira com os dados hemodinâmicos, assim como com a classificação funcional e com a distância caminhada no solo. Além disso, a distância percorrida no teste em esteira apresentou correlação significativa com a sobrevida, confirmando portanto, sua correlação com a gravidade da doença. A inalação de óxido nítrico(NO) durante o teste de caminhada levou a variações compatíveis com as variações hemodinâmicas frente à mesma dose de NO, sugerindo que o protocolo em questão possa refletir intervenções terapêuticas. Conclui-se que o protocolo de caminhada na esteira é um marcador funcional e prognóstico para pacientes com HAP, constituindo-se em um instrumento útil na avaliação de rotina de pacientes com HAP. / Pulmonary arterial hypertension (PAH) is a disease affecting the pulmonary arterial territory leading to progressive functional impairment and heart failure. Many different surrogate markers have been studied to evaluate PAH patients under the different treatment strategies that have been developed during the last decade. Among these markers, the six-minute walk test is the most used one. Although simple, many limitations exist mainly related to the need of appropriate physical area to perform the test properly. The aim of this study was to develop and validate a treadmill six-minute walk test for PAH patients evaluation. The developed protocol well correlated with other markers of disease severity as invasive hemodynamic data, functional class and even the distance walk at the hallway six minute walk test. Furthermore, the treadmill walked distance was associated to survival thus strengthening its ability to reflect disease severity. Nitric oxide (NO) inhalation during the treadmill walk test led to a variation in the walked distance proportional to the hemodynamic changes induced by the same dose of inhaled NO, suggesting that the developed protocol may be able to reflect at least acute therapeutical interventions. We conclude that the treadmill six minute walk test is a useful prognostic and functional marker for the routine evaluation of PAH patients.
7

Avalia??o da aptid?o cardiorrespirat?ria pelo Incremental Shuttle Walking Test em crian?as e adolescentes assintom?ticos do sexo masculino

Gomes, Andreza Let?cia 10 November 2017 (has links)
O orientador do trabalho n?o mencionado na lista da folha de aprova??o. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2018-08-06T18:31:52Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) andreza_leticia_gomes.pdf: 1090108 bytes, checksum: 96eed10c887fbcff28a65cbd64874639 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2018-10-05T19:12:17Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) andreza_leticia_gomes.pdf: 1090108 bytes, checksum: 96eed10c887fbcff28a65cbd64874639 (MD5) / Made available in DSpace on 2018-10-05T19:12:17Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) andreza_leticia_gomes.pdf: 1090108 bytes, checksum: 96eed10c887fbcff28a65cbd64874639 (MD5) Previous issue date: 2018 / O Incremental Shuttle Walking Test (ISWT) vem sendo utilizado na avalia??o da aptid?o cardiorrespirat?ria (ACR) de crian?as e adolescentes com diferentes condi??es de sa?de. N?o se sabe se a resposta cardiorrespirat?ria apresentada por adolescentes saud?veis no ISWT ir? se assemelhar aquela induzida pelo teste de esfor?o cardiopulmonar (TECP). Os objetivos deste estudo foram: (1) Avaliar se o ISWT ? um teste m?ximo para adolescentes assintom?ticos do sexo masculino. (2) Propor uma equa??o matem?tica para predizer o pico do consumo de oxig?nio (VO2 pico) e, (3) testar a confiabilidade dessa equa??o para essa popula??o. M?todos: No primeiro est?gio do estudo, 26 participantes realizaram o ISWT e o TECP. No segundo est?gio 50 participantes realizaram o ISWT duas vezes. Em ambos os est?gios foram avaliados VO2 pico, a frequ?ncia card?aca m?xima (FC m?x.) e o pico da raz?o de troca respirat?ria (R pico). No terceiro est?gio foram comparados os valores do VO2 pico preditos pela equa??o criada e obtidos de forma direta no ISWT. Resultados: N?o houve diferen?a significativa no VO2 pico, R pico e FC m?x. obtidos no ISWT e TECP. Os valores encontrados para o VO2 pico (r = 0,44. p = 0,002) e R pico (r = -0,53, p< 0,01) obtidos no ISWT e TECP apresentaram correla??o moderada e significativa, al?m de concord?ncia na an?lise de Bland-Altman. A velocidade da marcha foi a vari?vel que explicou 48% (R2 = 0,48, p = 0,000) da varia??o no VO2 pico no ISWT. Foi criada a equa??o VO2 previsto = 5,490 + (17,093 x Velocidade da Marcha). Os resultados obtidos pela equa??o foram comparados com os valores obtidos pelo analisador de gases e nenhuma diferen?a significativa foi encontrada entre eles. Conclus?es: Em crian?as e adolescentes do sexo masculino o ISWT ? um teste de esfor?o m?ximo com repercuss?es cardiorrespirat?rias similares ao TECP. A equa??o preditiva proposta ? uma estimativa vi?vel para predi??o do VO2 pico para essa popula??o. / Disserta??o (Mestrado Profissional) ? Programa de P?s-Gradua??o em Reabilita??o e Desempenho Funcional, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2017. / The Incremental Shuttle Walking Test (ISWT) has been used to evaluate the Cardiorespiratory Fitness (CRF) of children and adolescents with different pathological conditions. It is unknown whether the cardiorespiratory response presented by asymptomatic adolescents in ISWT will be similar to that induced by CardiopulmonaryExerciseStress Test (CEPT). The aims of this study were: (1) To evaluate whether ISWT is a maximum test for asymptomatic male adolescents. (2) To propose a mathematical equation to predict peak oxygen consumption (VO2 peak) and (3) Totest the reliability of this equation on this population. Methods: In the first stage of the study, 26 participants performed the ISWT and the CEPT. In the second stage 33 participants performed the ISWT twice. In both stages, peak VO2, maximal heart rate (HR max) and peak respiratory rate (peak R) were evaluated. In the third stage, the peak VO2 values predicted by the equation created and obtained directly in the ISWT were compared. Results: There was no significant difference in the peak VO2 (p> 0.05), peak R (p> 0.05) and maximum HR obtained in ISWT and CEPT. The values found for the VO2 peak (r = 0.44, p = 0.002) and peak R (r = -0.53, p <0.01) obtained in the ISWT and CEPT presented a moderate correlation and anagreement in the analysis of Bland-Altman analysis. The gait speed was the variable that explained 48% (R2 = 0.48, p = 0.000) of the variation in the peak VO2. The VO2 peak equation = 5.490 + (17.093 x Gait Speed) was created. The results obtained by the equation were compared with the values obtained by the gas analyzer and no significant differences were found between them (p> 0.05). Conclusion: ISWT produced a cardiorespiratory response comparable to CEPT in asymptomatic male adolescents, and the developed equation presented viability to predict peak VO2 in adolescents.
8

Associação entre o trabalho de caminhada de seis minutos e a capacidade aeróbia de pico em pacientes com doença pulmonar obstrutiva crônica

Poersch, Karla January 2009 (has links)
O teste de exercício cardiopulmonar incremental (TECP) tem sido utilizado para avaliar o impacto global da doença em pacientes com DPOC. Considerando que as avaliações de exercício em laboratório são demoradas, caras e muitas vezes indisponíveis, o teste de caminhada de seis minutos (TC6min) não exige equipamentos caros e sofisticados, e pode ser facilmente realizado. Embora, a principal medida comumente utilizada no teste de caminhada seja a distância percorrida durante os 6 minutos (D), esta medida não leva em conta as diferenças de peso corpóreo, que podem influenciar o desempenho do exercício. Além disso, estudos anteriores correlacionaram o trabalho realizado durante o TC6min com TECP incremental pedalando, modalidade de exercício comumente associada a fadiga de quadríceps e menor consumo de oxigênio de pico ( O2) do que o TECP caminhando. O principal objetivo desse estudo foi avaliar a correlação entre a distância percorrida no TC6min (D) e o produto distância percorrida - peso corporal (DxP), uma estimativa do trabalho realizado durante o TC6min, com o O2 de pico obtido durante o TECP incremental em esteira ergométrica. Foram estudados trinta pacientes (19 homens), apresentando média (± DP) de idade de 66,3 ± 7,5 anos, com DPOC estável de moderada a grave intensidade (VEF1 médio de 1,1 ± 0,4L e 39 ± 13% predito) que realizaram TECP incremental em esteira ergométrica até o limite máximo de tolerância e o TC6min. Os testes foram realizados com pelo menos 48 horas de intervalo. A correlação de Pearson foi utilizada para avaliar o nível de associação entre o O2 pico, a distância e o trabalho executado durante o TC6min. Os pacientes percorreram 425,1 ± 78,6 m e realizaram um trabalho de 28166,4 ± 8368,4 Kg-m durante o TC6min, enquanto que o O2 de pico atingido foi 965,6 ± 370,1 mL/min (68,7 ± 17,4% do previsto) no TCPE. Ao final do exercício, em ambos os testes, a dispnéia foi a principal queixa e maior percepção de dispnéia e maior frequência cardíaca foi observado ao final do TECP comparativamente ao TC6min. O trabalho da caminhada (DxP) durante o TC6min demonstrou maior correlação com o O2 pico do que a distância (D) isoladamente. O mesmo ocorreu para VEF1, CVF, CI, DLCO, CO2, E e duplo produto (uma estimativa do trabalho do miocárdio), (r = 0,57; r = 0,57; r = 0,73; r = 0,7; r = 0,75; r = 0,65; r = 0,51; r = 0,4 respectivamente, todos com p <0,05). Dessa forma, esse estudo corrobora a melhor associação entre o trabalho estimado a partir da TC6min e o O2 pico atingido durante TECP, neste caso em esteira ergométrica, em comparação à distância isoladamente. / Incremental cardiopulmonary exercise testing (CPET) is increasingly used to evaluate the overall impact of the illness in patients with COPD. Whereas laboratory tests of exercise performance are often time-consuming, costly and frequently unavailable, the six-minute walk test (6MWT) does not require expensive or sophisticated equipments, and can be easily performed. Although, the main outcome measure commonly used in this field test is the distance walked during the predetermined 6 minutes (6MWD), this measure does not account for differences in body weight that are known to influence exercise performance. Furthermore, previous studies correlated the working performed during 6MWT with incremental cycling CPET, an exercise modality more associated with quadriceps fatigability and lower peak oxygen consumption ( O2) than incremental walking tests. The main objective of this study is to evaluate the correlation between 6MWD and its derivative walking distance-body weight product, an estimation of the work performed during 6MWT, with peak O2 obtained during a treadmill incremental CPET. The study enrolled thirty patients (19 males), with a mean (± SD) age of 66.3 ± 7.5 years and a stable moderate-to-severe COPD (ie, mean FEV1 1.1 ± 0.4L and 39 ± 13 % predicted) performed a ramp incremental CPET to the limit of tolerance on a treadmill and 6MWT. Tests were performed at least 48 h apart. Pearson´s correlation was used to assess the level of association between peak O2 and the distance and work executed during 6MWT. The patients walked 425.1 ± 78.6 m and performed a work of 28,166.4 ± 8368.4 (Kg-m) during the 6MWT while achieved a peak O2 of 965.6 ± 370.1 mL/min (68.7 ± 17.4% of predicted) in the treadmill CPET. They mainly stopped exercise due to dyspnea in both tests and reported a greater perception of dyspnea and higher heart rate was observed at the end of the CPET. The work of walking during the 6-MWT (DxW) provided greater and more frequent significant correlation with peak O2 than that observed with 6MWD.This was the case for FEV1, FVC, IC, DLCO, CO2, E, and double product (an estimate of myocardial work) (r=0.57; r=0.57; r=0.73; r=0.7; r=0.75; r=0.65; r=0.51 and r= 0.4, respectively; all p<0.05). This study provides evidence to corroborate the better association between the work estimated from the 6MWT and peak O2 achieved during CPET, in this case with a treadmill, than the 6MWD on isolation.
9

Associação entre o trabalho de caminhada de seis minutos e a capacidade aeróbia de pico em pacientes com doença pulmonar obstrutiva crônica

Poersch, Karla January 2009 (has links)
O teste de exercício cardiopulmonar incremental (TECP) tem sido utilizado para avaliar o impacto global da doença em pacientes com DPOC. Considerando que as avaliações de exercício em laboratório são demoradas, caras e muitas vezes indisponíveis, o teste de caminhada de seis minutos (TC6min) não exige equipamentos caros e sofisticados, e pode ser facilmente realizado. Embora, a principal medida comumente utilizada no teste de caminhada seja a distância percorrida durante os 6 minutos (D), esta medida não leva em conta as diferenças de peso corpóreo, que podem influenciar o desempenho do exercício. Além disso, estudos anteriores correlacionaram o trabalho realizado durante o TC6min com TECP incremental pedalando, modalidade de exercício comumente associada a fadiga de quadríceps e menor consumo de oxigênio de pico ( O2) do que o TECP caminhando. O principal objetivo desse estudo foi avaliar a correlação entre a distância percorrida no TC6min (D) e o produto distância percorrida - peso corporal (DxP), uma estimativa do trabalho realizado durante o TC6min, com o O2 de pico obtido durante o TECP incremental em esteira ergométrica. Foram estudados trinta pacientes (19 homens), apresentando média (± DP) de idade de 66,3 ± 7,5 anos, com DPOC estável de moderada a grave intensidade (VEF1 médio de 1,1 ± 0,4L e 39 ± 13% predito) que realizaram TECP incremental em esteira ergométrica até o limite máximo de tolerância e o TC6min. Os testes foram realizados com pelo menos 48 horas de intervalo. A correlação de Pearson foi utilizada para avaliar o nível de associação entre o O2 pico, a distância e o trabalho executado durante o TC6min. Os pacientes percorreram 425,1 ± 78,6 m e realizaram um trabalho de 28166,4 ± 8368,4 Kg-m durante o TC6min, enquanto que o O2 de pico atingido foi 965,6 ± 370,1 mL/min (68,7 ± 17,4% do previsto) no TCPE. Ao final do exercício, em ambos os testes, a dispnéia foi a principal queixa e maior percepção de dispnéia e maior frequência cardíaca foi observado ao final do TECP comparativamente ao TC6min. O trabalho da caminhada (DxP) durante o TC6min demonstrou maior correlação com o O2 pico do que a distância (D) isoladamente. O mesmo ocorreu para VEF1, CVF, CI, DLCO, CO2, E e duplo produto (uma estimativa do trabalho do miocárdio), (r = 0,57; r = 0,57; r = 0,73; r = 0,7; r = 0,75; r = 0,65; r = 0,51; r = 0,4 respectivamente, todos com p <0,05). Dessa forma, esse estudo corrobora a melhor associação entre o trabalho estimado a partir da TC6min e o O2 pico atingido durante TECP, neste caso em esteira ergométrica, em comparação à distância isoladamente. / Incremental cardiopulmonary exercise testing (CPET) is increasingly used to evaluate the overall impact of the illness in patients with COPD. Whereas laboratory tests of exercise performance are often time-consuming, costly and frequently unavailable, the six-minute walk test (6MWT) does not require expensive or sophisticated equipments, and can be easily performed. Although, the main outcome measure commonly used in this field test is the distance walked during the predetermined 6 minutes (6MWD), this measure does not account for differences in body weight that are known to influence exercise performance. Furthermore, previous studies correlated the working performed during 6MWT with incremental cycling CPET, an exercise modality more associated with quadriceps fatigability and lower peak oxygen consumption ( O2) than incremental walking tests. The main objective of this study is to evaluate the correlation between 6MWD and its derivative walking distance-body weight product, an estimation of the work performed during 6MWT, with peak O2 obtained during a treadmill incremental CPET. The study enrolled thirty patients (19 males), with a mean (± SD) age of 66.3 ± 7.5 years and a stable moderate-to-severe COPD (ie, mean FEV1 1.1 ± 0.4L and 39 ± 13 % predicted) performed a ramp incremental CPET to the limit of tolerance on a treadmill and 6MWT. Tests were performed at least 48 h apart. Pearson´s correlation was used to assess the level of association between peak O2 and the distance and work executed during 6MWT. The patients walked 425.1 ± 78.6 m and performed a work of 28,166.4 ± 8368.4 (Kg-m) during the 6MWT while achieved a peak O2 of 965.6 ± 370.1 mL/min (68.7 ± 17.4% of predicted) in the treadmill CPET. They mainly stopped exercise due to dyspnea in both tests and reported a greater perception of dyspnea and higher heart rate was observed at the end of the CPET. The work of walking during the 6-MWT (DxW) provided greater and more frequent significant correlation with peak O2 than that observed with 6MWD.This was the case for FEV1, FVC, IC, DLCO, CO2, E, and double product (an estimate of myocardial work) (r=0.57; r=0.57; r=0.73; r=0.7; r=0.75; r=0.65; r=0.51 and r= 0.4, respectively; all p<0.05). This study provides evidence to corroborate the better association between the work estimated from the 6MWT and peak O2 achieved during CPET, in this case with a treadmill, than the 6MWD on isolation.
10

Impacto da força muscular periférica e respiratória na capacidade de exercício em indivíduos com e sem doença pulmonar obstrutiva crônica

Silva, Andréia Teresinha da January 2012 (has links)
Introdução: A força muscular periférica e respiratória pode estar reduzida em pacientes com doença pulmonar obstrutiva crônica (DPOC). O impacto desta redução sobre a capacidade de realizar atividades e exercícios não é bem conhecida. Objetivos: Comparar a força muscular periférica e respiratória e o desempenho no teste da caminhada de 6 minutos (TC6) e no teste de senta e levanta de 1 minuto (TSL) em indivíduos com e sem DPOC e estudar o impacto da força muscular nos dois testes. Métodos: Foram estudados 21 pacientes com DPOC (13 homens, idade de 63±7 anos, volume expiratório forçado no primeiro segundo - VEF1 – 1,14±0,54, 42±18% do previsto) e 21 indivíduos sem DPOC (13 homens, idade 64±7 anos, VEF1 2,64±0,65, 106±21% do previsto). Todos os indivíduos realizaram espirometria, avaliação da pressão inspiratória máxima (PImáx) e expiratória máxima (PEmáx), teste de uma repetição máxima (1RM) para avaliar força do quadríceps, TC6 e TSL. Resultados: Quando comparados com controles pacientes com DPOC apresentaram valores inferiores de PImáx (77±23 cm H2O vs 102±18 cm H2O, p=0,0001), PEmáx (100±26 cm H2O vs 127±23 cm H2O, p=0,001), força do quadríceps (17±5 Kg vs 23±4 Kg, p=0,0001), distância no TC6 (405±76 m vs 539±48 m, p=0,0001) e repetições no TSL (25±6 vs 35±6, p=0,0001). No grupo de 42 indivíduos a distância percorrida no TC6 se associou com o VEF1 (r=0,80, p=0,0001), com a PImáx (r=0,59, p=0,0001), com a PEmáx (r=0,63, p=0,0001), com a SpO2 basal (r=0,61, p=0,0001) e com a força do quadríceps (r=0,63, p=0,0001). Num modelo multivariado o VEF1, a PImáx e a dispneia basal explicaram 81% da variabilidade da distância percorrida no TC6. Em relação ao TSL as melhores correlações foram observadas com o VEF1 (r=0,55, p=0,0001) e com a força do quadríceps (r=0,50, p=0,0001) e associação mais fraca foi observada com as pressões respiratórias máximas (r=0,34, p=0,02). A distância percorrida no TC6 se associou com o número de repetições no TSL (r=0,61, p=0,0001). Conclusões: Pacientes com DPOC tem redução da força muscular do quadríceps e das pressões respiratórias e um pior desempenho no TC6 e no TSL em relação aos controles. Tanto a força muscular do quadríceps como as pressões respiratórias influenciam o desempenho nos dois testes. Entretanto, o impacto da força do quadríceps sobre a distância percorrida parece depender do VEF1. Observamos uma relação forte entre a distância percorrida e o número de elevações no TST, sugerindo que o TST possa ter um papel na avaliação funcional de pacientes com DPOC. / Introduction: Peripheral and respiratory muscle strength may be reduced in patients with chronic obstructive pulmonary disease (COPD). The impact of this reduction on the ability to perform activities and exercises is not well known. Aims: To compare the peripheral and respiratory muscle strength and the performance in a 6-minute walk test (6MWT) and a sit-to-stand test (STST) in subjects with and without COPD and to study the impact of the muscle strength on both tests. Methods: We studied 21 patients with COPD (13 men, age 63±7 years, forced expiratory volume in one second, FEV1 1.14±0.54, 42 ± 18% predicted ) and 21 subjects without COPD (13 men, age 64±7 years, FEV1 2.64±0.65, 106±21% predicted). All subjects underwent spirometry, maximal inspiratory (MIP) and expiratory pressure (MEP), one-repetition maximum (1RM) to evaluate quadriceps strength, 6MWT and STST. Results: When compared to controls patients with COPD showed lower values of MIP (77±23 cm H2O vs. 102±18 cm H2O, p=0.0001), MEP (100±26 cm H2O vs 127±23 cm H2O, p=0.001), quadriceps strength (17 ± 5 kg vs. 23 ± 4 kg, p=0.0001), distance in 6MWT (405±76 m vs 539±48 m, p = 0.0001) and repetitions in STST (25±6 vs 35±6, p=0.0001). The walked distance was associated with FEV1 (r=0.80, p=0.0001), MIP (r=0.59, p=0.0001), MEP (r=0.63, p=0.0001), baseline SpO2 (r=0.61, p=0.0001) and quadriceps strength (r=0.63, p=0.0001). In a multivariate model FEV1, MIP and baseline dyspnea explained 81% of the walked distance variance in 6MWT. Regarding the TSL, the best correlations were observed with FEV1 (r=0.55, p=0.0001) and quadriceps strength (r=0.495, p = 0.0001) while a weaker association was observed with the maximal respiratory pressures (r=0.34, p=0.02). The distance walked in 6MWT was associated with the number of repetitions in TSL (r=0.61, p=0.0001). Conclusions: Patients with COPD have reduced quadriceps muscle strength and respiratory pressures and a worse performance in the 6MWT and STST in relation to controls. Both the quadriceps muscle strength and respiratory pressure influenced the performance in both tests. However, the impact of quadriceps strength on the walked distance seems to depend on FEV1. We observed a strong relationship between distance and number of elevations in STST, suggesting that STST may have a role in the functional evaluation of patients with COPD.

Page generated in 0.0562 seconds