• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 14
  • 9
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 73
  • 73
  • 54
  • 37
  • 34
  • 30
  • 26
  • 21
  • 13
  • 12
  • 11
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Distriktssköterskans preventiva förhållningssätt mot sårinfektion : En kvalitativ intervjustudie / The district nurse’s preventive approach to wound infection : A qualitative interview study

Schagerström, Jonna, Schatz Jacobsson, Susann January 2023 (has links)
Background: The economic, social and clinical negative effects of hard- to- heal wounds continue to increase. Antimicrobial resistance is also increasing and is today a public health problem in the world. Wound infection should primarily be treated with local treatment based on a structured approach. Aim: The purpose of the study was to describe the district nurse's experiences and knowledge of wound treatment for preventive measures and treatment to counteract and eliminate wound infection. Method: A qualitative interview study with an inductive approach and strategic selection. Twelve district nurses from different parts of Sweden participated. Results: By using antimicrobial dressings, antibiotics could be avoided in many cases for treatment of local wound infection. The wound treatment was based on a holistic approach with continuity and a pursuit of cross-professional collaboration. It was expressed that continuous training in wound treatment is required for optimal wound treatment to be carried out. Conclusion: The district nurse has the ultimate responsibility for wound treatment and has extensive knowledge of how to use preventive care against wound infection. This led to a reduction in the use of antibiotics, which is an important step in preventing further development of antimicrobial resistance. However, continued education and research in this area is required. / Bakgrund: De ekonomiska, sociala samt kliniska negativa effekterna av ett svårläkt sår fortsätter att öka och så även antimikrobiell resistens, som idag klassas som ett folkhälsoproblem i världen. Sårinfektion bör i första hand behandlas med lokal behandling utifrån ett strukturerat förhållningssätt. Syfte: Studiens syfte var att beskriva distriktssköterskans erfarenheter och kunskaper kring sårbehandling och preventiva åtgärder för att motverka och häva sårinfektion. Metod: En kvalitativ intervjustudie med induktiv ansats och strategiskt urval. Tolv distriktssköterskor från olika delar av Sverige deltog.  Resultat: Genom användning av antimikrobiella förband kunde antibiotika i många fall undvikas som behandling vid lokal sårinfektion. Sårbehandlingen utgick från ett holistiskt synsätt med kontinuitet och en strävan efter ett tvärprofessionellt samarbete. Det uttrycktes att det krävs fortlöpande utbildning inom området för att optimal sårbehandling ska kunna bedrivas. Konklusion: Distriktssköterskan har det yttersta ansvaret för sårbehandling och har stor kunskap kring hur preventivt arbete mot sårinfektion kunde genomföras. Det medförde att användning av antibiotika minskade vilket är ett viktigt steg i att förhindra fortsatt utveckling av antimikrobiell resistens. Det krävs dock fortsatt utbildning och forskning inom det här området.
42

Auswirkung einer intensivierten Peritoneallavage und resistenzgerechten Antibiotikatherapie auf septische Komplikationen nach Pankreaskopfresektionen

Groß, Tina 17 January 2024 (has links)
Operationen an der Bauchspeicheldrüse stellen anspruchsvolle abdominalchirurgische Eingriffe dar. Trotz rückläufiger Mortalität in den vergangenen Jahrzehnten persistiert die Morbidität weiterhin bei 40-60% selbst an ausgewiesenen High-Volume Zentren (Hartwig et al., 2009). Pankreaskopfresektionen werden zum überwiegenden Anteil aufgrund eines malignen Prozesses im Bereich des Pankreaskopfes durchgeführt. Die komplette Tumorentfernung stellt die einzig kurative Therapieoption für diese Patienten:innen dar (AWMF Leitlinienprogramm Exokrines Pankreaskarzinom, 2021). Postoperative Komplikationen können den Beginn einer adjuvanten Therapie verzögern oder gar unmöglich machen und damit das mediane Überleben negativ beeinflussen. Maßgeblich sind hierfür septische Komplikationen verantwortlich (Vollmer et al., 2012; De Pastena et al., 2017). Eine Bakterobilie, die durch eine präoperative ERCP oder eine tumorbedingte Gallengangsobstruktion induziert werden kann korreliert mit einer erhöhten Rate an postoperativen Komplikationen insbesondere mit einer signifikant erhöhten Rate an Wundinfektionen (Surgical site infection [SSI]) (van der Gaag et al. 2007). In den intraoperativ entnommenen Gallenwegsabstrichen dominieren häufig Enterobacter- und Enterococcus-Spezies, welche in der Regel eine Resistenz gegenüber Cephalosporinen der ersten und zweiten Generation aufweisen (Ohgi et al. 2016, Sugiura et al. 2012). Vorangegangene Studien haben bereits einen positiven Effekt auf die SSI-Rate sowie auf das Auftreten weiterer septischer Komplikationen nach Pankreasresektion durch die Gabe einer an das Keimspektrum der Gallenwege angepassten Antibiotikatherapie nachweisen können (De Pastena et al., 2021). Der Einsatz einer Extensive intraoperative peritoneal lavage (EIPL) in der onkologischen Magenchirurgie führte zu einer signifikanten Reduktion der Mortalität, der Morbidität und der postoperativen Schmerzen. Zudem zeigte sich eine geringere Inzidenz für das Auftreten von septischen Komplikationen und eine höhere 5-Jahres-Überlebensrate (Jing Guo et.al., 2019, Kuramoto et.al., 2009). Vor diesem Hintergrund haben wir in dieser retrospektiven Studie untersucht ob durch den Einsatz einer EIPL und der Gabe einer an das biliäre Keimspektrum angepassten perioperativen Antibiotikaprophylaxe die Rate an septischen Komplikationen nach Pankreaskopfresektionen reduziert werden kann. Zudem sollte untersucht werden inwieweit diese Maßnahmen Einfluss auf die Morbidität und die Mortalität nehmen. Wir führten eine retrospektive Datenanalyse von 163 Patienten:innen durch, die im Zeitraum vom 24.05.2018 bis 20.05.2021 eine Pankreatikoduodenektomie in der Klinik für Viszeral-, Thorax- und Gefäßchirurgie am Universitätsklinikum Carl Gustav Carus in Dresden erhielten. Die Kontrollgruppe wurde durch 100 Patienten:innen gebildet, welche im Zeitraum vom 24.05.2018 bis zum 29.02.2023 operiert wurden. Diese Probanden:innen erhielten eine perioperative Antibiotikaprophylaxe mit einem Cephalosporin der Zweiten Generation (Cefuroxim) in Kombination mit einem Nitroimidazol (Metronidazol). Die Interventionsgruppe wurde durch 63 Probanden:innen gebildet, welche im Zeitraum vom 01.03.2020 bis zum 20.05.2021 operiert wurden. Diese Patienten:innen wurden perioperativ mit Piperazillin/ Tazobactam behandelt. Zudem erfolgte eine EIPL vor dem Verschluss der Abdominalhöhle. 46 Patienten:innen (28,2%) entwickelten postoperativ eine Wundinfektion. Vier fünftel dieser Patienten:innen waren Probanden aus der Kontrollgruppe (37,0%), wohingegen nur neun Patienten:innen (14,3%) aus der Interventionsgruppe eine SSI entwickelten. Sowohl in der univariaten als auch in der multivariaten Analyse bestätigte sich, dass der Einsatz einer an das Keimspektrum des Gallenwegssystem angepassten perioperativen Antibiotikaprophylaxe in Kombination mit einer EIPL ein protektiver Faktor für das Auftreten von SSI darstellt (OR=0,374; 95% KI=0,149-0,935; p=0,035). Ein hohes Patientenalter bestätigte sich als unabhängiger Risikofaktor für das Auftreten von SSIs (OR=2,607; 95% KI=1,107-6,142). Ein arterieller Hypertonus, ein hoher intraoperativer Blutverlust, eine Magenentleerungsstörung und eine Pankreasfistel waren in der univariaten Analyse ebenfalls als Risikofaktoren für das Auftreten von SSIs zu werten. In der multivariaten Analyse zeigten sich für diese Variablen jedoch keine signifikanten Ergebnisse. Weiterhin zeigte sich, dass die präoperative Gabe einer selektiven Darmdekontaminations (SDD)-Lösung zu einer signifikant niedrigeren SSI-Rate führte. Die Durchführung einer EIPL nimmt auf dieses Ergebnis keinen Einfluss. Inwiefern die SDD alleine ohne EIPL effektiv zur Senkung der SSI-Rate beiträgt, kann die vorliegende Studie nicht abschließend klären. Trotz unserer Ergebnisse kann keine generelle Empfehlung zur Gabe von Piperazillin/ Tazobactam gegeben werden. Es fehlen weiterführende randomisierter Studienergebnisse.:Inhalt I Abkürzungsverzeichnis III Abbildungsverzeichnis V Tabellenverzeichnis VI 1 Einleitung 1 1.1 Historische Entwicklung der Pankreaschirurgie 1 1.2 Indikationen für eine Pankreaskopfresektion 2 1.2.1 Exokrines Pankreaskarzinom 2 1.2.2 Chronische Pankreatitis 5 1.2.3 Zystische Pankreasraumforderungen 6 1.2.4 Neuroendokrine Pankreastumore 6 1.2.5 Raumforderungen der Papilla vateri 7 1.2.6 Raumforderungen des Duodenums 7 1.2.7 Distales Gallengangskarzinom 8 1.2.8 Metastasen 8 1.3 OP-Verfahren 8 1.3.1 Pylorus-erhaltende Pankreaskopfresektion 9 1.3.2 Operation nach Whipple-Kausch 11 1.3.3 Mesenteriko-portale Resektion 12 1.3.4 Arterielle Resektion 12 1.4 Perioperative Morbidität und Mortalität 13 1.5 Septische Komplikationen 13 1.6 Perioperatives Management 14 1.7 Zielsetzung 16 2 Material und Methoden 17 2.1 Einschlusskriterien 17 2.2 Ausschlusskriterien 17 2.3 Ethik und Datenmanagement 17 2.4 Datenerhebungen 17 2.4.1 Retrospektive Datenerhebung 17 2.4.2 Prospektive Datenerhebung 18 2.5 Statistische Analyse 22 3 Ergebnisse 23 3.1 Patientencharakteristika 23 3.2 Komorbiditäten 24 3.3 Perioperative Antibiotikaprophylaxe 26 3.4 Perioperative Charakteristika 27 3.5 Morbidität und Mortalität 28 3.6 Univariate Analyse der Risikofaktoren für SSI 31 3.7 Multivariate Analyse der Risikofaktoren für SSI 35 3.8 Einfluss von EIPL und SDD auf SSI 36 4 Diskussion 37 4.1 Patientencharakteristika 37 4.1.1 Geschlecht, Patientenalter und BMI 37 4.1.2 Komorbiditäten 38 4.1.3 Diagnose 39 4.1.4 Präoperative ERCP und neoadjuvante Chemotherapie 40 4.2 Perioperative Charakteristika 41 4.2.1 Operative Details 41 4.2.2 Operationslänge, intraoperativer Blutverlust, Operationserweiterungen 41 4.3 Septische Komplikationen 42 4.3.1 POPF 42 4.3.2 PPH und DGE 43 4.3.3 SSI und weitere septische Komplikationen 44 4.3.4 Reoperation, Krankenhausverweildauer, Mortalität 45 4.4 Weitere Risikofaktoren 46 4.5 Modifizierte Antibiotikaprophylaxe 46 4.6 Effekt der EIPL auf SSI 49 4.7 Auswirkung der SDD auf SSI 49 5 Schlussfolgerung 50 5.1 Limitation 50 5.2 Ausblick 51 6 Zusammenfassung 52 7 Summary 55 8 Literaturverzeichnis 57
43

Revisão sistemática sobre o uso de aventais cirúrgicos, conforme o material de confecção, no controle da contaminação/infecção do sítio cirúrgico / Systematic revision about the use of surgical gowns, according to the confection material, in the control contamination/surgical site infection

Burgatti, Juliane Cristina 27 August 2007 (has links)
O avental cirúrgico, um dos principais componentes de barreira antimicrobiana, é confeccionado com materiais de tecido e não-tecido. A Sociedade Norte-Americana de Enfermeiros do Centro Cirúrgico - AORN e a Norma Européia - EN 13795-3 recomendam que os aventais cirúrgicos devam prover uma barreira apropriada contra microrganismos, sangue e outros fluidos corpóreos (seco ou molhado). Tais recomendações, no entanto, não definem o que consideram como \"barreira apropriada\". O que ainda não foi comprovado, porém, é se o uso de materiais de não-tecido realmente interfere, isoladamente, tanto na contaminação da ferida operatória, quanto na ocorrência de ISC. O presente estudo teve como objetivo verificar se há evidências científicas, pela revisão sistemática de literatura, que fundamentem a prática do uso de aventais em cirurgias, conforme seu material de confecção. Foram considerados para a revisão sistemática apenas estudos básicos de intervenção, que investigaram a contaminação e ou a infecção do sítio cirúrgico com uso de aventais cirúrgicos reutilizáveis e ou de uso-único, utilizando como população pessoas submetidas a cirurgias, em situações reais ou simuladas, em qualquer período, sem limitação de idioma. Para localizar os estudos, utilizou-se a estratégia: P (pacientes) = pacientes cirúrgicos - surgical patients, I (intervenção) = roupa hospitalar ou roupa de proteção – clothing / protective clothing, C (comparação) = uso-único ou reutilizável - single-use or reusable, O (desfecho) = contaminação ou infecção da ferida operatória – surgical wound infection/contamination. A busca dos estudos orientou-se pelas bases de dados eletrônicas: LILACS, CINAHL, EMBASE, COCHRANE, PubMed/MEDLINE, pesquisa manual na revista da Sociedade Brasileira de Enfermeiros de Centro Cirúrgico (SOBECC) e referências dos estudos incluídos. Os dados analisados foram apresentados em três fases: Fase 1: Caracterização do processo de seleção dos estudos; Fase 2: Caracterização dos estudos incluídos; Fase 3: Avaliação da evidência dos estudos incluídos, a partir de duas escalas de qualidade, sendo uma delas a de Jadad e outra a de Controle de Infecção Cirúrgica (EQCIC), adaptada de Nobre e Bernardo. A amostra desta revisão sistemática constituiu-se de 12 estudos, sendo que apenas um deles investigou o avental isoladamente. Os demais investigaram principalmente os campos cirúrgicos juntamente com os aventais. Constata-se, com isso, dificuldade de isolar o objeto de intervenção de outros inúmeros fatores que podem interferir nos desfechos, em estudos desta natureza. Dois estudos (E1, E2) obtiveram forte evidência de recomendação, concluindo pela não diferença de contaminação e infecção do sítio cirúrgico entre aventais e campos de tecido e não-tecido. Devido à ausência de estudos semelhantes não houve a possibilidade de realizar a metanálise. A verificação isolada de aventais cirúrgicos depende de mais pesquisas bem controladas e delineadas. A contribuição desta investigação para a implementação de prática baseada em evidências mostrou-se relevante não somente para responder especificamente à questão da pesquisa, mas também para identificar qualidade, lacunas, falhas e recomendar aspectos a serem considerados nas próximas pesquisas desta natureza / The surgical gown, one of the main components of the antimicrobial barrier, is confectioned with woven and non-woven materials. The American Operating Room Nursing - AORN and The European Norm - EN 13795-3 recommend that the surgical gowns should provide an appropriate barrier against microorganisms, blood and other organic fluids (dry or wet). These recommendations, however, do not define, yet, what to consider an \"appropriate barrier\".. What has not been proved yet is if the use of non-woven materials influence, in an isolated way, both the contamination of an operation wound, and the occurrence of ISC. It was the objective of this present study to investigate if there is scientific evidence, by means of systematic revision, that founded the practice of use of gowns in surgery, according to its material of confections. Only basic studies of intervention that investigated the contamination and or surgical site infection with the use of surgical gowns reusable or single-use were considered in the systematic revision, which used as population people who underwent surgery, in real or simulated situations, in any period, without idiom limitation. To locate the studies, we used the PICO strategy: P (patients): surgical patients, I (intervention) = clothing/protective clothing, C (comparison) = single-use or reusable, O (outcome) = contamination or surgical wound infection. The search of studies was guided by the following electronic data bases: LILACS, PubMed/MEDLINE, EMBASE, COCHRANE, CINAHL, manual research in the magazine of Brazilian Society Operating Room Nursing (SOBECC) and references of included studies. The data analyses were shown in three phases: Phase 1: characterization of process of select studies; Phase 2: characterization of included studies; Phase 3: evaluation of the evidence found in the included studies, using two quality scales, being one this The Jadad and other Surgical Infection Control (EQCIC), adapted from Nobre and Bernardo. The sample of this systematic revision comprises 12 studies, being only one of them analyzed only gowns. The remainder investigated mainly the surgical fields together with the gowns. We can see thereby the difficulty in isolating the object of intervention from other countless factors that can influence outcomes, in studies of this nature. Two studies (E1, E2) found strong evidence of recommendation, concluding that there is no difference in terms of contamination and surgical wound infection between woven and non-woven gowns and drapes. Due to the absence of similar studies it is not possible to do some metanalysis. The isolated verification of surgical gowns needs more well controlled and delineated research. The contribution of this investigation to the implementation of practices based on evidences in showed relevant not only to answer specifically the question of research, but also to identify quality, gaps and flaws and recommend aspects to be considered in future research of this nature
44

Eficácia da esterilização a vapor de instrumental laparoscópico montado versus desmontado: um estudo experimental / Effectiveness of the steam sterilization of assembled versus disassembled laparoscopic instruments: an experimental study

Camargo, Tamara Carolina de 30 March 2007 (has links)
A vídeo-laparoscopia é uma inovação tecnológica que trouxe indiscutíveis vantagens e também novos desafios, incluindo nestes, as diretrizes para o reprocessamento adequado dos instrumentais e seus acessórios. A autoclavação dos instrumentais laparoscópicos desmontados é mais segura, uma vez que a condução térmica é facilitada. No entanto, são artigos complexos, compostos por múltiplas peças e a sua remontagem no momento da cirurgia traz transtornos às equipes cirúrgicas, correndo o risco do não funcionamento ou de danos às peças pela montagem inadequada. Existe um arraigado conceito, entre os profissionais da saúde, que para o sucesso da esterilização ser alcançado, é necessário o contato direto do vapor com todas as superfícies dos materiais submetidos à autoclavação sem considerar também o raciocínio do calor latente. A destruição microbiana por meio da esterilização pelo vapor está essencialmente relacionada ao calor latente, gerado pela condensação deste em contato com a superfície fria do material, promovendo a termocoagulação das proteínas microbianas. É uma prática comum nos hospitais brasileiros a realização da autoclavação de instrumentos previamente montados, apesar de não haver comprovação científica consistente dessa prática. Isto posto, esta investigação teve o objetivo de avaliar a eficácia do processo de esterilização a vapor dos instrumentais laparoscópicos previamente montados, comparando os seus resultados com os desmontados, considerada neste estudo a melhor prática. Tratou-se de uma pesquisa experimental, laboratorial, com abordagem quantitativa. Foram selecionados dois modelos de maior complexidade dentre os instrumentos laparoscópicos para realização do estudo, sendo eles: trocarte com válvula tipo janela rosqueada de 5mm, composto por cinco peças desmontáveis e pinça para dissecção de 5mm, composta por quatro peças desmontáveis. Cada peça dos instrumentais foi considerada como uma unidade amostral na análise microbiológica. Este estudo teve então como Grupo Montado: instrumentais laparoscópicos montados; Grupo Desmontado: instrumentais laparoscópicos desmontados; Grupo Contagem Microbiana: instrumentais laparoscópicos submetidos aos procedimentos de contaminação desafio, encaminhados diretamente para o teste de contagem microbiana. O inóculo para a contaminação desafio constitui-se de suspensão do Geobacillus stearothermophilus, na forma esporulada, acrescido de sangue de carneiro desfibrinado esterilizado. Todos os instrumentais foram contaminados desmontados com o inóculo desafio. Os grupos Montado e Desmontado foram submetidos aos processos de limpeza manual, complementada pela limpeza automatizada em lavadora ultra-sônica com retrofluxo, enxágüe em água corrente e sob pressão. Por fim, foi realizado o enxágüe com água destilada esterilizada e secagem com ar comprimido medicinal. Na seqüência, foi realizado sorteio para composição dos Grupos Montado e Desmontado. Os instrumentais foram embalados individualmente em papel grau cirúrgico e submetidos à esterilização a vapor em autoclave com pré-vácuo. Após a esterilização, os instrumentais foram avaliados quanto à eficácia da esterilização, por meio dos resultados dos testes de cultura microbiológica, utilizando o método de inoculação direta. No Grupo Montado foram recuperados os microrganismos teste em três peças de uma mesma pinça (3/48) e em três peças de um mesmo trocarte (3/60), enquanto que no Grupo Desmontado o microrganismo teste não foi recuperado nas unidades amostrais estudadas. Nas condições desse experimento, os resultados obtidos refutaram a hipótese inicial da pesquisa quanto à segurança da autoclavação das pinças e dos trocartes utilizados em cirurgia laparoscópica previamente montados / The video laparoscopy is a technological innovation that brought unquestionable advantages and, also, new challenges, like: the policies for the adequate reprocessing of the instruments and its permanent accessories. The steam sterilization of disassembled laparoscopic instruments is much safer, once that the thermal conduction is facilitated. However, laparoscopic instruments are quite complex articles; they are composed by many parts and the reassemblage in site at the moment of the surgery brings many inconveniences to the surgical team, like the possibility of the instrument’s malfunctioning or non functioning at all, or even damages to the instruments due to inadequate assembling. There is a strong belief among the Healthcare Professionals about the necessity of the direct contact of the steam with all the surface of the materials submitted to the steam sterilization, which is correct, however it doesn´t consider the latent heat assumption as well. The destruction of the microbiological material throughout the steam sterilization is essentially related to the latent heat, created by the vapor condensation when in contact with the instrument´s cold surface, promoting the thermal-coagulation of microbiological proteins. Many hospitals use the steam sterilization of previously mounted instruments, although there´s not any consistent scientific evidence about the efficiency of this practice. Once stated this point, this investigation´s aim was: evaluate the effectiveness of the steam sterilization process of the previously mounted, permanent laparoscopic instruments. It was an experimental laboratorial research, using a quantitative approach. Two models of permanent laparoscopic instruments of major complexity were chosen for the experiments: a trocar with a 5mm screw window valve, composed by five dismountable parts and a 5mm dissection clamp, composed by four dismountable parts. Each part of the instruments was considered as a sample unit on the microbiological analysis. This study it had the Assembled Group was: mounted laparoscopic instruments; the Disassembled Group was: disassembled laparoscopic instruments; the Microbiological Counting Group was: laparoscopic instruments submitted to the - challenge contamination - procedures, being directed straight to the test of microbiological counting. The inoculants material used for the challenge contamination consisted on the suspension of the Geobacillus stearothermophilus, in its spore form, plus defibrinated and sterilized sheep blood. All the instruments were contaminated, disassembled with the challenge inoculants material. The Assembled and Disassembled groups were submitted to the manual cleaning processes, enhanced by the automatic cleaning in an ultrasonic washer with retro-flux, rinsed in running and under pressure water. At last, a rinsing with distilled water was performed; the drying process was made with medicinal compressed air. Then, a sorting was performed to decide about the composition of the Assembled and Disassembled groups. The instruments were individually packed in surgical paper and submitted to the steam sterilization in a pre-vacuum sterilizer machine. After the sterilization, the instruments were evaluated according to sterilization effectiveness throughout the microbiological culture test´s results, using the straight inoculation method. In the Assembled Group the microorganism´s tests were recovered in three parts of one same clamp (3/48) and in three parts of the same trocar (3/60), in the Disassembled Group the test microorganism wasn´t recovered in any of the sample unities. The results, under the conditions of the experiment, refuted the hypothesis of safety in the usage of the steam sterilization in previously mounted used clamps and trocar in laparoscopy
45

Características e iniciativas institucionais que aprimoram as práticas de uso de antibioticoprofilaxia cirúrgica. / Characteristics and institutional initiatives that improve the surgical antibiotic prophylaxis use

Schmitt, Cristiane 02 April 2015 (has links)
Introdução: Os eventos adversos relacionados à assistência à saúde estão associados ao aumento da morbimortalidade e as IRAS correspondem entre 15% a 25% desses eventos. Há escassez de novos antimicrobianos, aumento de cepas resistentes e alto consumo dessas drogas. A adesão às diretrizes de antibioticoprofilaxia cirúrgica é pouco satisfatória e no Brasil há poucos dados sobre o assunto. Objetivo: reconhecer as características e iniciativas institucionais que aprimoram as práticas de uso de antibioticoprofilaxia em neurocirurgia. Objetivos específicos: identificar a conformidade; verificar a associação da conformidade com características de pacientes, cirurgias, hospitais, SCIH e processos relacionados à prevenção de ISC e uso de antibioticoprofilaxia; reconhecer a percepção de anestesiologistas e neurocirurgiões sobre as diretrizes institucionais. Método: Estudo observacional transversal, com população formada por hospitais, prontuários de pacientes neurocirúrgicos, profissionais dos SCIH, anestesiologistas e neurocirurgiões. A amostra de hospitais, anestesiologistas e neurocirurgiões foi tomada por conveniência e o número de prontuários para cada hospital foi calculado com base em 40% de conformidade geral. Resultados: Entre os nove hospitais avaliados, seis são privados, sete de grande porte e cinco tinham certificação de qualidade em 2010. O tempo médio de existência das CCIH foi de 21,9 anos e o dos SCIH de 19,4 anos. A média de horas semanais de profissionais do SCIH/leito hospitalar e por leito crítico foi 0,7 e 3,8, respectivamente. Oito hospitais divulgavam taxas de ISC, sete estratificada por especialidade cirúrgica. Seis hospitais construíram as diretrizes de antibioticoprofilaxia com anuência dos cirurgiões; em quatro deles as recomendações estavam completamente disseminadas e a taxa de adesão era monitorada e divulgada. As 1.011 neurocirurgias (craniotomias, artrodeses, laminectomias outras cirurgias), foram realizadas predominantemente em pacientes do sexo masculino, sendo a média de idade 49,6 anos. Foram excluídos da análise 38 procedimentos por falta de registro. A conformidade geral foi 10,0%; os maiores índices ocorreram nos hospitais 3 (28,9%), 1 (18,2%) e 8 (16,4%), ficando abaixo de 5% nos demais. No Hospital 9 a conformidade geral foi zero. A via administração estava conforme em 100% das neurocirurgias, dose em 90,6%, indicação em 90,0% e momento de início em 77,1%. Houve menor conformidade quanto à duração (26,1%), em 62,2% dos casos, mais longa que o recomendado. Houve associação estatisticamente significativa entre horas de profissionais do SCIH/leito de UTI (p 0,048), divulgação das diretrizes de uso de antibioticoprofilaxia cirúrgica (p 0,035), monitoramento da adesão (p 0,024), divulgação (p 0,015) dos resultados e a conformidade geral; período do dia em que a cirurgia ocorreu, dose (IC 1,72-6,65) e momento de início (IC 1,12-3,01) e tipo de cirurgia, momento de início (IC 1,24-4,25) e duração (IC 1,09-2,59). Foram entrevistados 43 profissionais de seis hospitais. Mais de 80% conheciam e concordavam as diretrizes institucionais e mais da metade referiu sempre segui-las; 37,0% dos anestesiologistas e 50,0% dos cirurgiões acreditavam que as diretrizes eram quase sempre seguidas por outros profissionais. Um cirurgião referiu nunca seguir e acreditar que outros profissionais nunca seguiam as diretrizes. As principais observações dos entrevistados foram falta de disciplina no centro cirúrgico e não divulgação das diretrizes de uso de antibioticoprofilaxia. Foi sugerido ao SCIH realizar treinamentos, disponibilizar amplamente as diretrizes, monitorar e divulgar a adesão às mesmas. Conclusão: O número de profissionais do SCIH/leito crítico, a divulgação das diretrizes, o monitoramento e a divulgação de resultados estão associados a maior conformidade quanto ao uso antibioticoprofilaxia cirúrgica. As inadequações identificadas parecem ter maior relação com resistência microbiana do que com ISC. Os SCIH tinham estrutura conforme exigido pela legislação, mas apresentavam lacunas quanto ao processo de implantação das diretrizes, monitoramento e divulgação de resultados. É imprescindível maior aproximação dos SCIH, especialmente, com os indivíduos envolvidos no processo cirúrgico, bem como a busca por soluções inovadoras, uma vez que os métodos convencionais de intervenção não estão produzindo os resultados desejados. / Introduction: healthcare-related adverse events are associated with increased morbidity and mortality and the Healthcare-associated Infections (HAI) account for 15% to 25% of these events. There is a shortage of new antimicrobials, increase in resistant strains and high consumption of these drugs. Adherence to surgical antibiotic prophylaxis guidelines is poor and there is little data on the subject in Brazil. Objective: to recognize the characteristics and institutional initiatives to improve antibiotic prophylaxis practices in neurosurgery. Specific objectives: identify adherence; verify the association of adherence with characteristics of patients, surgeries, hospitals, Hospital Infection Control Team (ICT) and processes related to prevention of Surgical Site Infection (SSI) and use of antibiotic prophylaxis; recognize the perception of anesthesiologists and neurosurgeons on institutional guidelines. Method: Cross-sectional observational study, carried out with a population consisting of hospitals, medical records of neurosurgical patients, ICT professionals, anesthesiologists and neurosurgeons. The sample of hospitals, anesthesiologists and neurosurgeons was used for convenience and the number of records for each hospital was calculated based on 40% of overall adherence. Results: Among the nine assessed hospitals, six are private, seven are large and five achieved quality certification in 2010. The mean time of Hospital Infection Control Committee (HICC) was 21.9 years and of ICT was 19.4 years. The mean weekly hours of ICT professionals per hospital bed and per critical bed was 0.7 and 3.8, respectively. Eight hospitals disclosed SSI rates, seven stratified by surgical specialty. Six hospitals created the antibiotic prophylaxis guidelines with the surgeons approval; the recommendations were fully disseminated in four and the rate of adherence was monitored and disclosed. The 1,011 neurosurgeries (craniotomy, arthrodesis, laminectomy and other surgeries), were performed predominantly in male patients with a mean age of 49.6 years. A total of 38 procedures were excluded from the analysis due to lack of records. Overall adherence was 10.0%; the highest rates were observed in Hospitals 3 (28.9%), 1 (18.2%) and 8 (16.4%), being <5% in the others. Overall adherence was zero in Hospital 9. The administration route was appropriate in 100% of the neurosurgeries, dose was appropriate in 90.6%, indication in 90.0% and time of onset in 77.1%. There was a lower adherence regarding duration (26.1%), in 62.2% of cases, longer than recommended. There was a statistically significant association between hours of ICT professional / ICU bed (p = 0.048), dissemination of surgical antibiotic prophylaxis use guidelines (p 0.035), adherence monitoring (p 0.024), disclosing of results (p 0.015) and the period of the day when the surgery occurred (CI = 1.7 to 6.6). A total of 43 professionals from six hospitals were interviewed. More than 80% knew about and agreed with the institutional guidelines and more than 50% reported they always followed them; 37.0% of anesthesiologists and 50.0% of surgeons believed that the guidelines were almost always followed by other professionals. One surgeon reported he never followed and believed that other professionals never followed the guidelines. The main observations of the respondents were lack of discipline in the operating room and lack of dissemination of antibiotic prophylaxis use guidelines. It was suggested to the ICT to carry out training, make the guidelines broadly available, monitor and promote adherence to them. Conclusion: The number of ICT professionals/critical bed, dissemination of guidelines, monitoring and disclosing of results are associated with higher adherence regarding antibiotic prophylaxis use; period of surgery, dose (IC 1,72-6,65) and initial time (IC 1,12-3,01) and surgery type, initial time (IC 1,24-4,25) and duration (IC 1,09-2,59). The identified inadequacies seem more related to microbial resistance than with SSI. The ICT had structure as required by law, but had shortcomings regarding the process of guideline implementation, monitoring and dissemination of results. It is of the utmost importance to promote better approach to ICT, especially with the individuals involved in the surgical process as well as the search for innovative solutions, as the conventional methods of intervention are not yielding the expected results.
46

Incidência e fatores associados à ocorrência de infecção de sítio cirúrgico nas fraturas diafisárias do fêmur e da tíbia tratadas com haste intramedular: estudo prospectivo / Incidence and factors associated with the occurrence of surgical site infection in femoral and tibial diaphyseal fractures treated with intramedullary nailing: prospective study

Oliveira, Priscila Rosalba Domingos de 27 June 2018 (has links)
INTRODUÇÃO: As fraturas diafisárias do fêmur e da tíbia encontram-se em destaque devido a sua elevada incidência e alto impacto econômico e social. A osteossíntese com uso da haste intramedular (HIM) é o procedimento cirúrgico de escolha. A infecção de sítio cirúrgico (ISC) relacionada a HIM é considerada uma complicação grave e de difícil tratamento. OBJETIVOS: 1. Determinar a incidência de ISC após a implantação de HIM para fixação de fraturas diafisárias de fêmur e tíbia. 2. Avaliar os possíveis fatores associados. MÉTODOS: Estudo prospectivo observacional do tipo coorte. Para definição de ISC, foram utilizados os critérios do CDC-NHSN. A incidência de ISC foi calculada como a relação entre o número de pacientes com ISC em relação ao número total de pacientes. Para avaliação dos potenciais fatores associados, foram analisados aqueles relacionados aos pacientes (idade, gênero, índice de massa corpórea, presença de focos ativos de infecção à distância, presença condições imunossupressoras, avaliação de estado físico segundo escore ASA, etilismo, tabagismo, uso de drogas ilícitas, politrauma, etiologia do trauma, tipo de fratura quanto à exposição óssea, classificação da fratura segundo Müller AO, classificação segundo Tcherne para as fraturas fechadas, classificação segundo Gustilo-Anderson para as fraturas expostas, permanência em outro serviço de saúde, uso prévio de fixador externo, antecedente de manipulação cirúrgica na topografia da fratura, uso de hemoderivados); dos fatores relacionados ao ambiente cirúrgico e ao ato operatório (classificação da ferida quanto ao potencial de contaminação, duração da cirurgia, tricotomia, possível contaminação intraoperatória, uso de antimicrobianos relacionados ao procedimento cirúrgico, uso de drenos, ocorrência de hipotermia ou hipóxia no período perioperatório, tipo de HIM utilizada, fresagem, necessidade de necessidade de reparo do revestimento cutâneo associado à topografia da fratura, uso de terapia por pressão negativa) e dos fatores relacionados à microbiota (colonização por S. aureus ou A. baumannii). RESULTADOS: 221 pacientes foram incluídos e completaram o período de 12 meses de seguimento. A incidência de ISC associada à osteossíntese com HIM foi de 11,8%. Na análise inicial por regressão logística não ajustada, os seguintes fatores apresentaram associação com ISC: etiologia do trauma relacionada a acidentes de carro e bicicleta, classificação Müller AO do traço da fratura 2 ou 3, uso prévio de fixador externo, cirurgias com maiores tempos de duração, uso de drenos, uso de terapia por pressão negativa e necessidade de reparo do revestimento cutâneo na topografia da fratura. Na análise ajustada por regressão logística múltipla, contudo, apenas o uso prévio de fixador externo e a necessidade de reparo do revestimento cutâneo mantiveram-se associados à ocorrência de ISC. CONCLUSÕES: A incidência de ISC associada à fixação de fraturas diafisárias de fêmur e tíbia com HIM foi de 11,8%. O uso prévio de fixadores externos e a necessidade de reparo do revestimento cutâneo na topografia da fratura foram fatores associados à ocorrência de infecção / BACKGROUND: Diaphyseal fractures of femur and tibia are prominent due to its high incidence and high economic and social impact. Intramedullary nailing (IN) is the surgical procedure of choice. Surgical site infection (SSI) related to this procedure is considered a difficult to treat complication. OBJECTIVES: Determine the incidence of SSI after IM in femoral and tibial diaphyseal fractures and evaluate possible risk factors. METHODS: Prospective observational cohort study. SSI was defined according to CDC-NHSN criteria. Incidence of SSI was calculated as the ratio between the number of patients with SSI and total number of patients. Analysis of potential risk factors included patients-related factors (age, gender, body mass index, active foci of infection, immunosuppressive conditions, ASA score, alcohol or illicit drug abuse, smoking, polytrauma, etiology of fracture, type of fracture if closed or open, classification of fracture according to Müller AO, Tcherne classification for closed fractures, to Gustilo-Anderson classification for open fractures, previous surgical manipulation, use of blood products); environmental and surgical-related factors (surgical wound classification, duration of surgery, hair removal, intraoperative contamination, antimicrobial use, presence of drains, hypothermia or hypoxia in the perioperative period, type of IN used, reaming, need for muscle or skin flap repair, use of negative pressure therapy) and microbiotarelated factors (S. aureus and A. baumannii colonization). RESULTS: 221 patients were included and completed the 12-month follow-up period. Incidence of SSI was 11.8%. In the initial analysis by unadjusted logistic regression, following factors were associated SSI: trauma etiology related to car and bicycle accidents, Müller AO classification of the fracture morphology groups 2 or 3, previous use of external fixator, surgeries with larger length of time, presence of drains, use of negative pressure therapy and need for muscle or skin flap repair. In the multiple logistic regression-adjusted analysis, previous use of external fixator and need for muscle or skin flap repair remained associated with SSI. CONCLUSIONS: Incidence of SSI associated with IN for femoral and tibial diaphyseal fractures was 11.8%. Previous use of external fixators and need for muscle or skin flap repair were factors associated with occurrence of infection
47

Avaliação da eficácia da esterização de furadeiras elétricas domésticas utilizadas em cirurgias ortopédicas / Evaluation of the efficacy of the sterilization of ordinary electric drills for orthopedic surgeries

Goveia, Vania Regina 20 December 2007 (has links)
Estima-se que há mais de 50 anos, as furadeiras elétricas (FE) têm sido empregadas em cirurgias ortopédicas nos hospitais brasileiros para a perfuração óssea. Trata-se de equipamento elétrico, termossensível, não indicado para uso cirúrgico, não avaliado anteriormente quanto à eficácia da esterilização, suspeitando-se de risco potencial para infecções do sítio cirúrgico ou relacionadas a próteses ortopédicas. Os objetivos desse estudo foram: avaliar a carga microbiana de FE do uso cirúrgico e avaliar a eficácia da esterilização por óxido de etileno (ETO) de FE novas intencionalmente contaminadas. Trata-se de pesquisa experimental, laboratorial, randomizada e aplicada desenvolvida no laboratório de pesquisas experimentais da Escola de Enfermagem da Universidade de São Paulo. O trabalho foi realizado em duas fases. As condições assépticas foram rigorosamente seguidas para o controle das variáveis. Quinze FE analisadas na fase I, tiveram distribuição aleatória e cega, capturadas em um centro cirúrgico de um hospital escola. Foram cultivados: o ar gerado pelo motor e alíquotas de 10 µL do lavado das superfícies interna e externa das FE. Ainda nessa fase foi realizado um controle positivo onde uma FE foi contaminada com Serratia marcescens e um teste do método de filtração por membrana de porosidade de 0,45 µm com uma FE limpa, onde as membranas que filtraram diferentes quantidades do lavado foram cultivadas. Na fase II foram analisadas 22 FE e três perfuradores de osso (PO). Dezesseis FE constituíram o grupo experimental (GE), seis o controle positivo (GCP) e três PO constituíram o controle negativo (GCN). Todos os equipamentos previamente limpos e esterilizados foram submetidos à contaminação com esporos de Bacillus atrophaeus. As FE do GCP foram analisadas após a exposição ao contaminante, furadeiras do GE e perfuradores do GCN foram submetidos à limpeza e esterilização por ETO antes de serem analisados. Foram cultivados: ar gerado pelo motor e membrana filtrante após a filtração do lavado das superfícies interna e externa dos equipamentos. Foram realizadas coloração e microscopia: Gram para culturas positivas; Wirtz-Conklin para culturas positivas com bacilos Gram positivos. Os resultados mostraram que a carga microbiana de FE do uso cirúrgico é baixa e foi detectada em duas ocasiões no cultivo do ar, 1 ufc/FE e em uma ocasião no cultivo de alíquotas do lavado, 9 ufc/FE. O controle positivo realizado com Serratia marcescens comprovou a sensibilidade do método para amostras contendo alta concentração de contaminantes. O método filtração por membrana mostrou-se sensível para detectar baixa contaminação das FE, sendo o eleito para o teste de esterilidade. Os controles positivos apresentaram crescimento do microrganismo contaminante, comprovando a aderência ao material. Os controles negativos não apresentaram crescimento. Das 16 FE do GE, duas apresentaram crescimento sendo cada uma delas de 1ufc do contaminante inicial respectivamente no cultivo do ar e no cultivo da membrana. Foi comprovada a eficiência de 99,99999881% do processo de esterilização por ETO, com a probabilidade de sobrevivência de 1,19 x 10-8. Nas condições do desenvolvimento do experimento, a eficácia da esterilização das FE por ETO foi comprovada / Electric drills have been used to perform orthopedic surgeries in Brazilian hospitals for almost more than 50 years. This electric equipment is heat-sensitive and it is not appropriate to use in surgical procedures. Until now the efficacy of sterilization of this item had been not evaluated as a potential risk for the occurrence of surgical site infection or infection related to orthopedic prosthesis. The objectives of this study were to evaluate the bioburden of the used electric drills and to evaluate the sterility of the new electric drills contaminated artificially. It is an experimental and randomized study performed in the research laboratory of the Nursing School of the São Paulo University. The study was performed in two phases following rigorous aseptic techniques to control the variables. In the first phase fifteen electric drills were taken in the operating room of the university hospital and included in the study using aleatory and blind methods. Cultures were performed from the air produced by the drill engine and the aliquots of 10µL of the rinsed water from the internal and external surface of the electric drill. One electric drill was included as a positive control and was contaminated with Serratia marcescens. A membrane filter with porous of 0,45 µm were cultured after had been exposed to the rinsed water from the internal and external surface of the clean electric drill. In the second phase were analyzed twenty two electric drills and three orthopedic drilling machines. Sixteen electric drills were included in the experimental group, six were the positive control group and three orthopedic drilling machines in the negative control group. All the equipments previously cleaned and sterilized were submitted to the contamination with Bacillus atrophaeus. The electric drills included in the positive control group were analyzed after exposed to the contaminant and the electric drills of the experimental group and orthopedic drills included in the negative control group were submitted to clean and ethylene oxide sterilization before to start the analysis. The air produced by the drill engine and the membrane filter after exposed to the rinsed water of the internal and external surface of the electric drill were cultured. It was performed Gram microscopy and Wirtz-Conklin to Gram positive bacilli. The results showed low bioburden in the electric drills in two episodes. So, 1 cfu/electric drill was found in one episode of the air culture and 9 cfu/electric drill in one episode of culture of the aliquot. The positive control with Serratia marcescens demonstrated the sensibility of the method in samples with high concentration of contaminants. The method of membrane filtration showed sensible to detect low bioburden of the electric drills. So it is elected for the sterility test. The positive controls showed the growth of the contaminant microrganism demonstrating the adherence to the material surface. The negative controls did not show growth. Two of the sixteen electric drills included in the experimental group showed each one growth of 1cfu of the initial contaminant of the air and the membrane cultures respectively. So the efficiency of the sterilization process was 99,99999881% and the probability of find survivor was 1,19 x 10-8. In these conditions the study demonstrates that the efficacy of the ethylene oxide sterilization was proved
48

Revisão sistemática sobre o uso de aventais cirúrgicos, conforme o material de confecção, no controle da contaminação/infecção do sítio cirúrgico / Systematic revision about the use of surgical gowns, according to the confection material, in the control contamination/surgical site infection

Juliane Cristina Burgatti 27 August 2007 (has links)
O avental cirúrgico, um dos principais componentes de barreira antimicrobiana, é confeccionado com materiais de tecido e não-tecido. A Sociedade Norte-Americana de Enfermeiros do Centro Cirúrgico - AORN e a Norma Européia - EN 13795-3 recomendam que os aventais cirúrgicos devam prover uma barreira apropriada contra microrganismos, sangue e outros fluidos corpóreos (seco ou molhado). Tais recomendações, no entanto, não definem o que consideram como \"barreira apropriada\". O que ainda não foi comprovado, porém, é se o uso de materiais de não-tecido realmente interfere, isoladamente, tanto na contaminação da ferida operatória, quanto na ocorrência de ISC. O presente estudo teve como objetivo verificar se há evidências científicas, pela revisão sistemática de literatura, que fundamentem a prática do uso de aventais em cirurgias, conforme seu material de confecção. Foram considerados para a revisão sistemática apenas estudos básicos de intervenção, que investigaram a contaminação e ou a infecção do sítio cirúrgico com uso de aventais cirúrgicos reutilizáveis e ou de uso-único, utilizando como população pessoas submetidas a cirurgias, em situações reais ou simuladas, em qualquer período, sem limitação de idioma. Para localizar os estudos, utilizou-se a estratégia: P (pacientes) = pacientes cirúrgicos - surgical patients, I (intervenção) = roupa hospitalar ou roupa de proteção – clothing / protective clothing, C (comparação) = uso-único ou reutilizável - single-use or reusable, O (desfecho) = contaminação ou infecção da ferida operatória – surgical wound infection/contamination. A busca dos estudos orientou-se pelas bases de dados eletrônicas: LILACS, CINAHL, EMBASE, COCHRANE, PubMed/MEDLINE, pesquisa manual na revista da Sociedade Brasileira de Enfermeiros de Centro Cirúrgico (SOBECC) e referências dos estudos incluídos. Os dados analisados foram apresentados em três fases: Fase 1: Caracterização do processo de seleção dos estudos; Fase 2: Caracterização dos estudos incluídos; Fase 3: Avaliação da evidência dos estudos incluídos, a partir de duas escalas de qualidade, sendo uma delas a de Jadad e outra a de Controle de Infecção Cirúrgica (EQCIC), adaptada de Nobre e Bernardo. A amostra desta revisão sistemática constituiu-se de 12 estudos, sendo que apenas um deles investigou o avental isoladamente. Os demais investigaram principalmente os campos cirúrgicos juntamente com os aventais. Constata-se, com isso, dificuldade de isolar o objeto de intervenção de outros inúmeros fatores que podem interferir nos desfechos, em estudos desta natureza. Dois estudos (E1, E2) obtiveram forte evidência de recomendação, concluindo pela não diferença de contaminação e infecção do sítio cirúrgico entre aventais e campos de tecido e não-tecido. Devido à ausência de estudos semelhantes não houve a possibilidade de realizar a metanálise. A verificação isolada de aventais cirúrgicos depende de mais pesquisas bem controladas e delineadas. A contribuição desta investigação para a implementação de prática baseada em evidências mostrou-se relevante não somente para responder especificamente à questão da pesquisa, mas também para identificar qualidade, lacunas, falhas e recomendar aspectos a serem considerados nas próximas pesquisas desta natureza / The surgical gown, one of the main components of the antimicrobial barrier, is confectioned with woven and non-woven materials. The American Operating Room Nursing - AORN and The European Norm - EN 13795-3 recommend that the surgical gowns should provide an appropriate barrier against microorganisms, blood and other organic fluids (dry or wet). These recommendations, however, do not define, yet, what to consider an \"appropriate barrier\".. What has not been proved yet is if the use of non-woven materials influence, in an isolated way, both the contamination of an operation wound, and the occurrence of ISC. It was the objective of this present study to investigate if there is scientific evidence, by means of systematic revision, that founded the practice of use of gowns in surgery, according to its material of confections. Only basic studies of intervention that investigated the contamination and or surgical site infection with the use of surgical gowns reusable or single-use were considered in the systematic revision, which used as population people who underwent surgery, in real or simulated situations, in any period, without idiom limitation. To locate the studies, we used the PICO strategy: P (patients): surgical patients, I (intervention) = clothing/protective clothing, C (comparison) = single-use or reusable, O (outcome) = contamination or surgical wound infection. The search of studies was guided by the following electronic data bases: LILACS, PubMed/MEDLINE, EMBASE, COCHRANE, CINAHL, manual research in the magazine of Brazilian Society Operating Room Nursing (SOBECC) and references of included studies. The data analyses were shown in three phases: Phase 1: characterization of process of select studies; Phase 2: characterization of included studies; Phase 3: evaluation of the evidence found in the included studies, using two quality scales, being one this The Jadad and other Surgical Infection Control (EQCIC), adapted from Nobre and Bernardo. The sample of this systematic revision comprises 12 studies, being only one of them analyzed only gowns. The remainder investigated mainly the surgical fields together with the gowns. We can see thereby the difficulty in isolating the object of intervention from other countless factors that can influence outcomes, in studies of this nature. Two studies (E1, E2) found strong evidence of recommendation, concluding that there is no difference in terms of contamination and surgical wound infection between woven and non-woven gowns and drapes. Due to the absence of similar studies it is not possible to do some metanalysis. The isolated verification of surgical gowns needs more well controlled and delineated research. The contribution of this investigation to the implementation of practices based on evidences in showed relevant not only to answer specifically the question of research, but also to identify quality, gaps and flaws and recommend aspects to be considered in future research of this nature
49

Incidência e fatores associados à ocorrência de infecção de sítio cirúrgico nas fraturas diafisárias do fêmur e da tíbia tratadas com haste intramedular: estudo prospectivo / Incidence and factors associated with the occurrence of surgical site infection in femoral and tibial diaphyseal fractures treated with intramedullary nailing: prospective study

Priscila Rosalba Domingos de Oliveira 27 June 2018 (has links)
INTRODUÇÃO: As fraturas diafisárias do fêmur e da tíbia encontram-se em destaque devido a sua elevada incidência e alto impacto econômico e social. A osteossíntese com uso da haste intramedular (HIM) é o procedimento cirúrgico de escolha. A infecção de sítio cirúrgico (ISC) relacionada a HIM é considerada uma complicação grave e de difícil tratamento. OBJETIVOS: 1. Determinar a incidência de ISC após a implantação de HIM para fixação de fraturas diafisárias de fêmur e tíbia. 2. Avaliar os possíveis fatores associados. MÉTODOS: Estudo prospectivo observacional do tipo coorte. Para definição de ISC, foram utilizados os critérios do CDC-NHSN. A incidência de ISC foi calculada como a relação entre o número de pacientes com ISC em relação ao número total de pacientes. Para avaliação dos potenciais fatores associados, foram analisados aqueles relacionados aos pacientes (idade, gênero, índice de massa corpórea, presença de focos ativos de infecção à distância, presença condições imunossupressoras, avaliação de estado físico segundo escore ASA, etilismo, tabagismo, uso de drogas ilícitas, politrauma, etiologia do trauma, tipo de fratura quanto à exposição óssea, classificação da fratura segundo Müller AO, classificação segundo Tcherne para as fraturas fechadas, classificação segundo Gustilo-Anderson para as fraturas expostas, permanência em outro serviço de saúde, uso prévio de fixador externo, antecedente de manipulação cirúrgica na topografia da fratura, uso de hemoderivados); dos fatores relacionados ao ambiente cirúrgico e ao ato operatório (classificação da ferida quanto ao potencial de contaminação, duração da cirurgia, tricotomia, possível contaminação intraoperatória, uso de antimicrobianos relacionados ao procedimento cirúrgico, uso de drenos, ocorrência de hipotermia ou hipóxia no período perioperatório, tipo de HIM utilizada, fresagem, necessidade de necessidade de reparo do revestimento cutâneo associado à topografia da fratura, uso de terapia por pressão negativa) e dos fatores relacionados à microbiota (colonização por S. aureus ou A. baumannii). RESULTADOS: 221 pacientes foram incluídos e completaram o período de 12 meses de seguimento. A incidência de ISC associada à osteossíntese com HIM foi de 11,8%. Na análise inicial por regressão logística não ajustada, os seguintes fatores apresentaram associação com ISC: etiologia do trauma relacionada a acidentes de carro e bicicleta, classificação Müller AO do traço da fratura 2 ou 3, uso prévio de fixador externo, cirurgias com maiores tempos de duração, uso de drenos, uso de terapia por pressão negativa e necessidade de reparo do revestimento cutâneo na topografia da fratura. Na análise ajustada por regressão logística múltipla, contudo, apenas o uso prévio de fixador externo e a necessidade de reparo do revestimento cutâneo mantiveram-se associados à ocorrência de ISC. CONCLUSÕES: A incidência de ISC associada à fixação de fraturas diafisárias de fêmur e tíbia com HIM foi de 11,8%. O uso prévio de fixadores externos e a necessidade de reparo do revestimento cutâneo na topografia da fratura foram fatores associados à ocorrência de infecção / BACKGROUND: Diaphyseal fractures of femur and tibia are prominent due to its high incidence and high economic and social impact. Intramedullary nailing (IN) is the surgical procedure of choice. Surgical site infection (SSI) related to this procedure is considered a difficult to treat complication. OBJECTIVES: Determine the incidence of SSI after IM in femoral and tibial diaphyseal fractures and evaluate possible risk factors. METHODS: Prospective observational cohort study. SSI was defined according to CDC-NHSN criteria. Incidence of SSI was calculated as the ratio between the number of patients with SSI and total number of patients. Analysis of potential risk factors included patients-related factors (age, gender, body mass index, active foci of infection, immunosuppressive conditions, ASA score, alcohol or illicit drug abuse, smoking, polytrauma, etiology of fracture, type of fracture if closed or open, classification of fracture according to Müller AO, Tcherne classification for closed fractures, to Gustilo-Anderson classification for open fractures, previous surgical manipulation, use of blood products); environmental and surgical-related factors (surgical wound classification, duration of surgery, hair removal, intraoperative contamination, antimicrobial use, presence of drains, hypothermia or hypoxia in the perioperative period, type of IN used, reaming, need for muscle or skin flap repair, use of negative pressure therapy) and microbiotarelated factors (S. aureus and A. baumannii colonization). RESULTS: 221 patients were included and completed the 12-month follow-up period. Incidence of SSI was 11.8%. In the initial analysis by unadjusted logistic regression, following factors were associated SSI: trauma etiology related to car and bicycle accidents, Müller AO classification of the fracture morphology groups 2 or 3, previous use of external fixator, surgeries with larger length of time, presence of drains, use of negative pressure therapy and need for muscle or skin flap repair. In the multiple logistic regression-adjusted analysis, previous use of external fixator and need for muscle or skin flap repair remained associated with SSI. CONCLUSIONS: Incidence of SSI associated with IN for femoral and tibial diaphyseal fractures was 11.8%. Previous use of external fixators and need for muscle or skin flap repair were factors associated with occurrence of infection
50

Vårdpersonals syn på hygieniska preoperativa förberedelser : En kvalitativ intervjustudie

Arnstigen, Sara, Axelsson, Christer January 2008 (has links)
<p>Abstrakt</p><p>Bakgrund: Länge har man varit medveten om vikten av god hygien och dess inverkan på</p><p>smittspridning. Det mest effektiva sättet att minska postoperativa sårinfektioner (SSI) är att arbeta</p><p>förebyggande och att ha en god hygien. Frekvensen av SSI ökar, och som en del av den förebyggande</p><p>vården ingår den preoperativa förberedelsen. Att inte ha kunskap och stöd till att utföra en sådan</p><p>åtgärd korrekt är en stor brist och kan leda till att patienter drabbas av SSI och därmed ett ökat</p><p>postoperativt lidande.</p><p>Syfte: Studiens syfte var att beskriva vårdpersonalens syn på betydelsen av hygienisk preoperativ</p><p>förberedelse hos ortopedpatienter.</p><p>Metod: Studien genomfördes på ett länssjukhus i mellersta norrland under våren 2008, där alla</p><p>ortopedavdelningar på sjukhuset deltog. En kvalitativ intervjumetod användes med manifest</p><p>innehållsanalys av materialet.</p><p>Resultat: All personal som ingått i studien anser att den hygieniska preoperativa förberedelsen är av</p><p>stor vikt. Trots faktorer som stress, personalbrist och hög arbetsbelastning kände personalen att de</p><p>ville vara noggrann i sitt arbete och göra det bästa för patienten, även genomföra en bra förberedelse</p><p>innan operation. Den största orsaken till att de frångick de skrivna rutinerna var att patienterna hade</p><p>ont, samt vid akuta situationer då det var svårt att planera sitt arbete.</p><p>Diskussion: Trots att personalen visste om förberedelsens betydelse för frekvensen av SSI och att de</p><p>tyckte att riktlinjerna inte förändrats på många år, valde de medvetet att vissa gånger frångå de rutiner</p><p>som finns och de tog inget eget ansvar för att hålla sig uppdaterad kring ny forskning.</p> / <p>Abstract</p><p>Background: Long has one been aware about the importance of good hygiene and its effect on</p><p>infection control. The most effective way to decrease surgical site infections (SSI) is to work</p><p>preventive and to have a good hygiene. The frequency of SSI increases and as a part of the preventive</p><p>care the hygienic preoperative preparation is included. To not have knowledge and aids to carrying out</p><p>such a measure correct is a big deficiency and can lead to patients being hit of SSI and with that</p><p>increased postoperative suffering</p><p>Aim: The study's aim was to describe the care personnel's view on the importance of hygiene</p><p>preoperative preparation at orthopaedic patients.</p><p>Method: The study was implemented on a county hospital in the north central part of Sweden during</p><p>the spring of 2008, where all orthopaedic departments on the hospital participated. A qualitative</p><p>interview method was used with a manifest content analysis of the material.</p><p>Results: All personnel as been included in the study were unanimous that hygienic preoperative</p><p>preparation was of big importance. Despite factors like stress, lack of personnel and high workload,</p><p>they wanted to be accurate in their work and do what’s best for the patient. That also implemented a</p><p>good preparation before operation. The major reason to not follow the guidelines where that the</p><p>patients was in acute pain, and in emergency situations when it were impossible to plan its work.</p><p>Discussion: Despite the knowledge about the importance of preparation for the frequency of SSI and</p><p>they thought that the guideline not been changed on many years, they sometimes deliberately chose</p><p>not to follow the guideline. The nurses took no responsibility in order to keep updated around new</p><p>research.</p>

Page generated in 0.089 seconds