• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 181
  • 125
  • 74
  • 37
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 718
  • 718
  • 280
  • 273
  • 159
  • 141
  • 105
  • 102
  • 75
  • 70
  • 67
  • 63
  • 58
  • 57
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
491

Análise do escoamento de fluidos refrigerantes alternativos ao HCFC22 em tubos capilares adiabáticos. / Analysis of HCFC 22 alternative refrigerant fluids flow through adiabatic capillary tubes.

Fiorelli, Flávio Augusto Sanzovo 15 December 2000 (has links)
Este trabalho apresenta os resultados da pesquisa "Análise do Escoamento de Fluidos Refrigerantes Alternativos ao HCFC 22 em Tubos Capilares Adiabáticos", desenvolvida para obtenção do título de Doutor em Engenharia no Departamento de Engenharia Mecânica da EPUSP. Essa pesquisa foi motivada pelas resoluções do Protocolo de Montreal, que prevêem a eliminação gradativa do HCFC 22 e, conseqüentemente, impõem a necessidade da realização de estudos sobre o comportamento de fluidos alternativos ecologicamente aceitáveis nos sistemas de refrigeração e seus componentes. Até o momento, as pesquisas e as referências bibliográficas indicam a utilização de misturas zeotrópicas e quase-azeotrópicas como a melhor alternativa para substituição do HCFC 22. Desta forma, foi realizado um extenso levantamento experimental do escoamento do R-407C (uma mistura zeotrópica) e do R-410A (uma mistura quase-azeotrópica) através de tubos capilares, em uma unidade laboratorial construída para essa finalidade. Esse levantamento, realizado para condições de entrada subresfriada e saturada, caracterizou a influência destes fluidos refrigerantes e dos diversos parâmetros operacionais e geométricos no comportamento do tubo capilar em sistemas de refrigeração. Foram desenvolvidos dois modelos (fases separadas e homogêneo) para a modelagem matemática do escoamento de fluidos refrigerantes através de tubos capilares, a fim de verificar o efeito do tipo de escoamento adotado nessa modelagem. A validação dos programas de simulação desenvolvidos, tanto para os dados experimentais obtidos no presente trabalho quanto para dados de literatura, mostra que os dois modelos podem ser utilizados para essa modelagem, apresentando desvios semelhantes em relação aos dados experimentais. A fim de aprimorar os modelos, é necessária a realização de estudos mais aprofundados sobre o atraso de vaporização e a ocorrência de blocagem na saída do tubo capilar. Por fim, foi realizado um estudo numérico comparativo do desempenho do HCFC 22 e dos alternativos R-407C e R-410A, que indicou que o primeiro é adequado tanto para o "retrofit" de equipamentos existentes quanto para utilização em novos equipamentos, enquanto que o segundo deve ser utilizado apenas em novos equipamentos. / This work presents the results of the research activities on the "Analysis of HCFC 22 Alternatives Flow Through Adiabatic Capillary Tubes", developed at the Mechanical Engineering Department of Escola Politécnica da Universidade de São Paulo. Such research was motivated by the resolutions of Montreal Protocol, which imposes gradational elimination of several refrigerants, among them HCFC 22. This leads to the necessity of carrying out studies on the behaviour of ecologically acceptable refrigerants in refrigeration systems and components. So far, researches and literature indicate the usage of zeotropic and near azeotropic refrigerant mixtures as the best alternative to HCFC 22. Therefore, it was performed an extensive experimental survey on R-407C (a zeotropic mixture) and R-410A (a near azeotropic mixture) flow through capillary tubes. Such survey, which was carried out for both subcooled and two-phase inlet conditions, characterised the influence of these refrigerants, as well as the several operating and geometric parameters on the behaviour of capillary tubes used in refrigeration systems. In order to analyse the effect of different approaches for two-phase flow, it was developed two models (separated flow model and homogeneous model) for mathematical simulation of refrigerant flow through adiabatic capillary tubes. Models validation using both experimental and literature data shows that the two models are suitable for such simulation, with the same error level in relation to experimental data. It was also noticed that it is necessary to perform more comprehensive studies on the delay of vaporisation and capillary tube outlet shocking flow phenomena. Finally, it was performed a comparative study on the performance of HCFC 22, R-407C and R-410A, which indicates that R-407C is suitable both for retrofitting actual equipment and for new ones, while R-410A is suitable only for new equipment.
492

Análise computacional da automação das temperaturas de água gelada, de água de condensação e ar de insuflação em um edifício comercial. / Computational analysis of automation of temperatures of chilled water, condenser water and supply air in a comercial building.

Diaz Valdivia, Javier 10 December 2018 (has links)
A automação de uma central de água gelada é muito utilizada para reduzir o consumo energético de edificações comerciais ao controlar a operação dos seus componentes e consequentemente das vazões de ar e água em função da carga térmica. Considerando as estratégias de controle atualmente em uso, existe a possibilidade de melhorá-las por meio do controle das variáveis de temperatura do sistema (temperaturas de insuflação do ar, da água gelada e da água de condensação), que na maioria dos casos são mantidas fixas para as condições de dimensionamento do sistema ou alteradas apenas em função das condições externas. Estudos demonstram que o controle adequado de cada uma dessas temperaturas nas condições de operação momentâneas (condições climáticas e carga térmica), seja de forma individualizada ou integradas, pode proporcionar reduções significativas no consumo de energia do sistema de climatização. Dessa forma, o presente estudo avaliou os ganhos de uma automação isolada e integrada dessas três temperaturas em base anual para as condições climáticas brasileiras, implementando a automação em diferentes cidades representativas do zoneamento bioclimático brasileiro via simulação computacional utilizando o software EnergyPlus(TM) para uma edificação comercial típica. Os resultados obtidos para a automação integrada indicam reduções globais de consumo que variam com a condição climática entre 5,03% e 19,68% quando comparado com o controle de temperatura fixa, e quando comparado com um controle que varia apenas em função das condições externas as reduções variam entre 3,22% e 8,21%. Esses resultados demonstram que o controle sugerido é melhor que os modelos adotados como referência de mercado. / Automation of a central chilled-water plant is widely used to reduce the energy consumption of commercial buildings by controlling the operation of its components and consequently the air and water flow rates according to the thermal load. Considering the control strategies currently in use, there is a possibility to improve them by controlling the system temperature variables (air insufflation, cold and condensation water temperatures), which in most cases are fixed in system design conditions or variable only according to the external weather. Studies demonstrate that an adequate control of each of these temperatures under momentary operating conditions (climatic conditions and thermal load), whether in an individualized or integrated way, can provide significant reductions in the energy consumption of the HVAC system. Thus, the present study intends to evaluate the energy consumption gains of an individualized and integrated automation of the three variable temperatures on an annual basis for Brazilian climatic conditions, implementing automation for different cities representing the Brazilian bioclimatic zoning. Such evaluation was made by computer simulation using EnergyPlus(TM) software for a typical commercial building. The results obtained with the integrated automation show savings in global consumption that change with the weather between 5,03% and 19,68% when compared with a fixed control, and when compared with a control that varies according to weather conditions the savings are between 3,22% and 8,21%. These results show that the proposed control is better than both models adopted as market benchmarks.
493

Modelagem de sistema de controle de ar condicionado baseado em redes de Petri. / Air conditioning control systems modelling using Petri nets.

Almeida, Antonio Gabriel Souza 16 October 2008 (has links)
Dentre as tendências de uso racional de recursos, principalmente energia, e da necessidade de assegurar a produtividade e qualidade na execução de atividades produtivas, destaca-se o conceito de edifício inteligente. Este ambiente materializa o conceito de integração dos sistemas prediais potencializando a otimização dos recursos e a eficiência do trabalho humano. Neste contexto, abordagens conceituais baseadas em sistemas a eventos discretos e técnicas derivadas de rede de Petri têm sido introduzidas como uma alternativa eficaz de modelagem e análise das soluções de integração dos sistemas prediais. Um resultado expressivo destas iniciativas são os métodos propostos para a modelagem e análise de estratégias de gerenciamento de sistemas de ar condicionado, utilizando uma abordagem híbrida, onde são considerados os aspectos de sistemas a eventos discretos e as variáveis de dinâmica contínua. Contudo, as abordagens e métodos existentes são limitados a soluções específicas de implementação, como os sistemas de ar condicionado com volume de ar contínuo. Assim, o presente trabalho introduz uma extensão destas abordagens para modelar e analisar soluções de automação predial que incluem sistemas de ar condicionado com volume de ar variável. A eficiência deste método na concepção e validação destas soluções é ilustrada através de um estudo de caso. / Among the trends of rational use of resources, especially energy, and the need to ensure productivity and quality in the implementation of productive activities, there is the concept of intelligent building. This environment materializes the concept of integrating building systems, powering the optimization of resources and the efficiency of human labor. In this context, conceptual approaches that are based on systems of discreet events and techniques, which are derived from the Petri nets, have been introduced as an effective alternative to modeling and analysis of solutions of building systems integration. A significant result of these initiatives are the proposed methods for modeling and the analysis of strategies for air conditioning systems management using a hybrid approach where the aspects of systems of discreet events and the variables of continuing dynamic are considered. However, the existing methods and approaches are limited to their specific implementation solutions, such as air conditioning systems with continuous volume of air. Thus, this work introduces an extension of these approaches to model and analyze the building automation solutions that include air conditioning systems with variable volume of air. The efficiency of this method in the design and validation of these solutions is illustrated through a case study.
494

Avaliação do conforto térmico e do nível de CO2 em edifícios de escritório com climatização artificial na cidade de São Paulo. / Thermal comfort and CO2 level evaluation in air-conditioned office biuldings in São Paulo.

Suzuki, Eliane Hayashi 18 October 2010 (has links)
O conforto térmico e a qualidade do ar interior são fatores importantes a serem considerados tanto na fase de projeto quanto na operação dos edifícios. Este trabalho tem como objetivo avaliar as condições do ambiente térmico durante operação do sistema de condicionamento de ar por meio de medições em campo no período de verão. A pesquisa foi realizada em nove edifícios corporativos com climatização artificial na cidade de São Paulo, que foram selecionados conforme critérios pré-estabelecidos de sistema central com distribuição de ar por dutos. A estratégia de medição e o dimensionamento estatístico do número de amostras por edifício foram determinados de acordo com os resultados das primeiras medições. Coletaram-se os dados dos parâmetros ambientais com instrumentação correspondente em três pavimentos aleatórios de cada edifício. Posteriormente, compararam-se os dados com os níveis estipulados por normas técnicas nacionais e internacionais de conforto térmico e qualidade do ar interior, a fim de verificar a eficiência dos sistemas de distribuição de ar dos edifícios pesquisados no que diz respeito à remoção de poluentes, baseado na medição da concentração de dióxido de carbono, e ao provimento do conforto através da análise de variáveis como temperatura, umidade relativa e velocidade do ar. Os resultados mostraram que a maior parte da amostra se enquadrou nas categorias de ambientes térmicos estabelecidos pelas normas e que existe um potencial de conservação de energia nos edifícios de escritório em São Paulo. / Thermal comfort and indoor air quality are important factors to be considered during building design and operation. This study aims to evaluate thermal environment conditions during air conditioning system operation through field measurements in summer. The survey was conducted in nine office buildings with mechanical cooling in São Paulo. Measurement strategy and statistical determination of the number of samples per building were determined in accordance to the results of initial measurements. Environmental parameters data was collected with corresponding instrumentation in buildings and then compared with the levels required by national and international standards for thermal comfort and indoor air quality in order to verify air distribution efficiency in regard of pollutants removal, based on carbon dioxide concentration, and the provision of comfort through the analysis of variables such as temperature, relative humidity and air velocity. The results showed that most of the sample fitted into the categories of thermal environment established by the standards and that there is potential for saving energy in air-conditioned buildings in Sao Paulo.
495

Estudo da qualidade do ar interior em ambientes educacionais. / Study of indoor air quality in educational environments.

Fakhoury, Nícolas Alexandre 12 May 2017 (has links)
A Qualidade do Ambiente Interior (QAI) é um dos principais fatores que determina a funcionalidade, harmonia, conforto e produtividade em um edifício. A QAI afeta a saúde e o conforto dos ocupantes de um edifício, bem como a habilidade dos mesmos em realizar tarefas, influenciando diretamente na produtividade. Quando a QAI é boa, os ambientes se tornam lugares mais desejáveis para estar, trabalhar e aprender. O ambiente de escolas e universidades pode exercer um impacto significativo na saúde e no aprendizado de crianças e estudantes universitários. A limitação da entrada de poluentes e contaminantes, bem como o fornecimento da quantidade adequada de ar externo filtrado e limpo, melhoram o desempenho acadêmico dos estudantes e não atinge a saúde dos mesmos. Este trabalho apresenta medições de parâmetros físicos e químicos, CO2, PM2,5, PM10, temperatura de bulbo seco e umidade relativa, efetuadas em uma sala de aula do prédio de Engenharia Mecânica da Escola Politécnica da Universidade de São Paulo (EPUSP) os quais os estudantes e professores estavam sujeitos. As medidas foram tomadas no ambiente interno e externo a sala de aula, onde atividades teóricas e práticas eram realizadas. A vazão de ar externo, previamente filtrado, era variada para a redução dos contaminantes gerados internamente. Constatou-se que os particulados PM2,5 e PM10 atingiram concentrações críticas de 6 e 30 vezes maiores do que o limite proposto pelas normas vigentes, respectivamente, bem como a concentração de CO2 que atingiu 3 vezes o limite recomendado. Porém, observou-se que o aumento da vazão de ar externo em aproximadamente 2200 m³/h foi suficiente para a diminuição da concentração de PM10 em 50% nos primeiros 20 minutos. Apesar da diminuição da concentração, a vazão recomendada de ar externo por pessoa não foi suficiente para a concentração de material particulado atingir os limites aceitáveis. Por fim, apresenta-se uma proposta de projeto detalhado de dois sistemas independentes de tratamento de ar que permitirão a realização de experimentos e estudos sobre a QAI, podendo-se variar a vazão de ar externo e a classe de filtragem da recirculação e da tomada de ar externo para dois laboratórios do Departamento de Engenharia Mecânica da EPUSP, que podem dar sequência aos estudos deste trabalho. / The Indoor Environmental Quality (IEQ) is one of the main factors that determines the functionality, harmony, comfort and productivity in a building. The IEQ affects the health and comfort of the occupants of a building, as well as the ability of them to perform tasks, influencing directly in productivity. When IEQ is good, the environments become more desirable places to be in, work and learn. The indoor environment of schools and universities can have a significant impact on the health and learning of children and college students. The limitation of input of pollutants and contaminants, as well as providing the appropriate amount of filtered and clean outside air, improve the academic performance of students and does not affect the health of the same. This paper presents measurements of physical and chemical parameters, CO2, PM2,5, PM10, dry bulb temperature and relative humidity, made in a classroom of the Mechanical Engineering building of the Polytechnic School of the University of São Paulo (EPUSP) which students and teachers were subject. The measurements were taken in the internal and external environment of the classroom, where theoretical and practical activities were conducted. The flow of outside air, previously filtered, was varied for the reduction of contaminants generated internally. It was found that the particulate PM2,5 and PM10 achieved critical concentrations of 6 and 30 times greater than the limit proposed by the current standards, respectively, and that the concentration of CO2 reached 3 times the recommended limit. However, it was observed that increasing outside air flow of approximately 2200 m³/h was enough to decrease the concentration of PM10 in 50% at the first 20 minutes. Despite the decreased concentration, the recommended flow of outside air per person was not enough for the concentration of particulate matter reaches the acceptable limits. Finally, a detailed project proposal is presented of two independent air treatment systems that will allow performing experiments and studies on the IEQ, being able to vary the flow of outside air and, the filters of the recirculation and external air intake for two laboratories of the Department of Mechanical Engineering of EPUSP, that can follow the studies of this work.
496

Room air conditioner preference and country of origin in Hong Kong and Zhu Hai.

January 1995 (has links)
by Chow Kar Tak, Kelly, Chan Wai Shing, Cheung Wai Hung, Daniel. / Includes questionnaire in Chinese. / Thesis (M.B.A.)--Chinese University of Hong Kong, 1995. / Includes bibliographical references (leaves [33]-[35]). / Chapter 1. --- Introduction --- p.1 / Chapter 2. --- The Room Air Conditioners Market in Hong Kong and Zhu Hai --- p.3 / Chapter 3. --- Sample Characteristics --- p.4 / Chapter 4. --- Choice Criteria of Room Air Conditioning Units --- p.7 / Chapter 4.1 --- Country of Brand --- p.12 / Chapter 4.2 --- Country of Production --- p.15 / Chapter 4.3 --- Price --- p.20 / Chapter 4.4 --- Quietness --- p.22 / Chapter 4.5 --- Reliability --- p.23 / Chapter 4.6 --- Additional Features --- p.24 / Chapter 4.7 --- Size --- p.25 / Chapter 5. --- Conclusion --- p.26 / Appendix A -List of Tables / Appendix B -Reference / Appendix C - Survey Questionnaire for Hong Kong / Appendix D - Survey Questionnaire for Zhu Hai
497

Análise computacional da automação das temperaturas de água gelada, de água de condensação e ar de insuflação em um edifício comercial. / Computational analysis of automation of temperatures of chilled water, condenser water and supply air in a comercial building.

Javier Diaz Valdivia 10 December 2018 (has links)
A automação de uma central de água gelada é muito utilizada para reduzir o consumo energético de edificações comerciais ao controlar a operação dos seus componentes e consequentemente das vazões de ar e água em função da carga térmica. Considerando as estratégias de controle atualmente em uso, existe a possibilidade de melhorá-las por meio do controle das variáveis de temperatura do sistema (temperaturas de insuflação do ar, da água gelada e da água de condensação), que na maioria dos casos são mantidas fixas para as condições de dimensionamento do sistema ou alteradas apenas em função das condições externas. Estudos demonstram que o controle adequado de cada uma dessas temperaturas nas condições de operação momentâneas (condições climáticas e carga térmica), seja de forma individualizada ou integradas, pode proporcionar reduções significativas no consumo de energia do sistema de climatização. Dessa forma, o presente estudo avaliou os ganhos de uma automação isolada e integrada dessas três temperaturas em base anual para as condições climáticas brasileiras, implementando a automação em diferentes cidades representativas do zoneamento bioclimático brasileiro via simulação computacional utilizando o software EnergyPlus(TM) para uma edificação comercial típica. Os resultados obtidos para a automação integrada indicam reduções globais de consumo que variam com a condição climática entre 5,03% e 19,68% quando comparado com o controle de temperatura fixa, e quando comparado com um controle que varia apenas em função das condições externas as reduções variam entre 3,22% e 8,21%. Esses resultados demonstram que o controle sugerido é melhor que os modelos adotados como referência de mercado. / Automation of a central chilled-water plant is widely used to reduce the energy consumption of commercial buildings by controlling the operation of its components and consequently the air and water flow rates according to the thermal load. Considering the control strategies currently in use, there is a possibility to improve them by controlling the system temperature variables (air insufflation, cold and condensation water temperatures), which in most cases are fixed in system design conditions or variable only according to the external weather. Studies demonstrate that an adequate control of each of these temperatures under momentary operating conditions (climatic conditions and thermal load), whether in an individualized or integrated way, can provide significant reductions in the energy consumption of the HVAC system. Thus, the present study intends to evaluate the energy consumption gains of an individualized and integrated automation of the three variable temperatures on an annual basis for Brazilian climatic conditions, implementing automation for different cities representing the Brazilian bioclimatic zoning. Such evaluation was made by computer simulation using EnergyPlus(TM) software for a typical commercial building. The results obtained with the integrated automation show savings in global consumption that change with the weather between 5,03% and 19,68% when compared with a fixed control, and when compared with a control that varies according to weather conditions the savings are between 3,22% and 8,21%. These results show that the proposed control is better than both models adopted as market benchmarks.
498

A responsabilidade empresarial prevista no art. 931 do Código Civil de 2002 aplicada à progressiva inclusão de nanotecnologia no setor de ar condicionado automotivo : uma proposta para aplicação do princípio da precaução e gestão do risco inerente ao uso e descarte de materiais nanoestruturados

Cassali, Nina Koja 31 October 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-02-22T14:12:57Z No. of bitstreams: 1 Nina Koja Cassali_.pdf: 3033674 bytes, checksum: fc57aae5e0f87cd498d187aa91053777 (MD5) / Made available in DSpace on 2018-02-22T14:12:57Z (GMT). No. of bitstreams: 1 Nina Koja Cassali_.pdf: 3033674 bytes, checksum: fc57aae5e0f87cd498d187aa91053777 (MD5) Previous issue date: 2017-10-31 / Nenhuma / A presente pesquisa trata da nanotecnologia e suas possíveis implicações no ramo da responsabilidade civil atribuída a empresários e sociedades empresárias pelo Código Civil de 2002, bem como suas resultantes em meio à sociedade. A falta de regulamentação relativa à nanotecnologia e a extensa probabilidade de riscos que representa, somada às diretrizes impostas pelo artigo 931 do CC em vigor, deu azo à proposta de elaboração de um framework baseado nos procedimentos a serem adotados com o fito inicial de dirimir a repercussão nefasta de futura responsabilização, mas acima de tudo, de preservar a saúde humana e ambiental. Para tanto, utilizou-se pesquisa bibliográfica, levantamento de dados e análise de normas internacionais. A pesquisa concluiu acerca do fato de que produtos à base de nanotecnologia fazem parte de uma realidade cada vez mais presente na vida de todos e que está em franca expansão. O desconhecimento acerca da nocividade das nanopartículas engenheiradas já presentes na atmosfera releva-se a razão basilar pela qual todos os estágios da vida útil dos nanomateriais devam ser rigorosamente controlados e analisados, mormente em face de seu potencial tóxico, obstando seus prováveis malefícios tanto quanto possível, para que, sem frustrar o progresso tecnológico, haja a garantia da permanência da vida humana como hoje conhecemos. Sustentado em tais valores, elaborou-se a sugestão de gerenciamento de risco materializado no framework ora proposto. / This research deals with nanotechnology and its possible implications in the field of civil liability attributed to entrepreneurs and business companies by the Civil Code of 2002, as well as its resulting in the society. The lack of regulations related to nanotechnology and the high probability of risks that it represents, together with the guidelines imposed by article 931 of the current CC, gave rise to the proposal of elaboration of a framework based on the procedures to be adopted with the initial intention to resolve the Harmful repercussions of future accountability, but above all, of preserving human and environmental health. For this purpose, bibliographic research, data collection and analysis of international standards were used. The research concluded that nanotechnology-based products are part of a rapidly expanding reality in everyone's life. The lack of knowledge about the harmfulness of the engineered nanoparticles already present in the atmosphere depends on the basic reason why all stages of nanomaterials' life must be rigorously controlled and analyzed, especially in the face of their toxic potential, hindering their probable harms as much as possible , So that, without frustrating technological progress, there is the guarantee of the permanence of human life as we know it today. Based on these values, the risk management suggestion materialized in the proposed framework was elaborated.
499

Avaliação do desempenho de um sistema de refrigeração automotivo com ejetor em ciclo COS

Ferreira, Henrique Schardosin 29 September 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-04-25T13:35:45Z No. of bitstreams: 1 Henrique Schardosin Ferreira_.pdf: 4214270 bytes, checksum: b40eaaf06dd9b49a976b944788dce2f1 (MD5) / Made available in DSpace on 2018-04-25T13:35:45Z (GMT). No. of bitstreams: 1 Henrique Schardosin Ferreira_.pdf: 4214270 bytes, checksum: b40eaaf06dd9b49a976b944788dce2f1 (MD5) Previous issue date: 2017-09-29 / Nenhuma / Nessa dissertação foi apresentado um estudo do uso do ejetor bifásico em um sistema de refrigeração para condicionamento de ar automotivo, para recuperação das perdas de energia durante o processo de expansão. Um modelo numérico foi utilizado para a predição do ganho energético com a aplicação do ejetor com base no ciclo padrão de ejetor proposto por Gay (1931). Posteriormente, foi proposto um modelo numérico para a determinação das dimensões básicas necessárias para a fabricação do ejetor. Uma bancada de simulação construída para o ciclo de refrigeração padrão para condicionamento de ar automotivo foi modificada para a instalação do ejetor e passou a operar de acordo com o ciclo COS de Oshitani et al. (2005). Dos diversos modelos matemáticos existentes na literatura, foi escolhido um modelo de simulação de ciclo de ejetor para operação em regime subcrítico da análise unidimensional proposta por Kornhauser (1990) e para a solução do modelo foram desenvolvidos programas computacionais no software EES - Engineering Equation Solver, no qual as rotinas de cálculos foram construídas para solução numérica iterativa visando à determinação do ponto ótimo de operação do ciclo. Para comprovação do modelo e dos resultados obtidos pelos programas, foi repetida a análise apresentada por Kornhauser (1990) e os resultados comparados com os seus. Os resultados gerados pelos programas mostraram boa aderência aos publicados por autores que estudaram aplicação semelhante, sendo assim considerados confiáveis na aplicação para predição de desempenho de ciclos com ejetor em operação com fluidos em regime subcrítico. A bancada de testes instalada no Laboratório de Estudos Térmicos e Fluido Dinâmicos da Unisinos (LETEF), construída por Souza (2011) e posteriormente utilizada por Noetzold (2016) na simulação do ciclo padrão de refrigeração de um sistema de condicionamento de ar automotivo foi alterada para instalação do ejetor em operação sob configuração do ciclo COS. A adoção do ciclo COS se deu em função da incerteza do retorno de óleo e do controle da separação das fases do refrigerante no acumulador de sucção do ciclo padrão. O sistema foi submetido as condições de operação previstas na norma SAE J2765 OCT2008 (2008) e operou com R-134a. Os resultados foram comparados com os do ciclo padrão de Noetzold (2016) apresentando aumento médio do COP do ciclo de 25% para a faixa de baixa rotação e de 46% para a faixa de alta rotação e comparados também aos resultados de Lawrence (2012). / In this work was presented a study of the use of the ejector in a cooling system for automotive air conditioning, to recover energy losses during the expansion process. A numerical model was used to predict the energetic gain with ejector application based on the ejector standard cycle proposed by Gay (1931). Subsequently, a numerical model was proposed to determine the basic dimensions necessary for the ejector manufacturing. A simulation system for the standard refrigeration cycle for automotive air conditioning was modified for the ejector installation and started to operate according to the COS cycle by Oshitani et al. (2005). From the several mathematical models in the literature, a model of the ejector cycle simulation for subcritical fluids of the one-dimensional analysis proposed by Kornhauser (1990) was chosen, and for the solution of the model computational programs were developed in the EES - Engineering Equation Solver software in which the calculation routines were constructed for iterative numerical solution in order to determine the optimum operating point of the cycle. To prove the model and the results obtained by the programs, the analysis presented by Kornhauser (1990) and the results compared were repeated. The results generated by the programs showed good results, being thus considered reliable in the application to predict performance of ejector cycles in operation with sub-critical fluids. The simulation system installed in the Laboratory of Thermal and Dynamic Fluid Studies of Unisinos (LETEF), built by Souza (2011) and later used by Noetzold (2016) in the simulation of the standard refrigeration cycle of an automotive air conditioning system, was changed for installation of the ejector in operation under COS cycle configuration. The choice of the COS cycle was due to the uncertainty of the oil return to compressor and the control of the separation of the phases of the refrigerant in the suction accumulator of the standard cycle. The system was subjected to the operating conditions set forth in the standard SAE J2765 OCT2008 (2008) and operated with R-134a. The results were compared with those of standard cycle by Noetzold (2016), showing a mean increase of the cycle COP of 25% for the low rotation range and 46% for the high rotation range and also compared to Lawrence (2012).
500

Análise do COP anual de condicionadores de ar tipo Split fixo e inverter nas diferentes zonas bioclimáticas brasileiras

Rech, Letícia Dotta 12 April 2018 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-08-01T14:35:36Z No. of bitstreams: 1 Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) / Made available in DSpace on 2018-08-01T14:35:36Z (GMT). No. of bitstreams: 1 Letícia Dotta Rech_.pdf: 7163933 bytes, checksum: b8456d05a1d302c866b6a463943d0889 (MD5) Previous issue date: 2018-04-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta uma análise da relação entre o desempenho de equipamentos de condicionamento de ar tipo Split, fixo e inverter, para a climatização de uma edificação comercial nas diferentes zonas bioclimáticas brasileiras. As análises foram realizadas por simulação computacional, através do programa EnergyPlus. Foram simulados oito casos seguidos pelo modelo de referência. O modelo de referência adotado foi criado a partir de um levantamento fotográfico de edificações comerciais padrões com mais de quatro pavimentos. A partir deste levantamento, a tipologia que foi adotada representa um edifício de dez pavimentos com perímetro de dimensões de 27 por 7,50 metros e, pé-direito de 2,60 metros. Para analisar o comportamento energético do modelo de referência foram inseridos dados dos componentes construtivos, do padrão de ocupação, das cargas energéticas do sistema de iluminação e dos equipamentos, do condicionamento de ar, com as suas respectivas curvas de desempenho, conforme fornecedor, e de infiltração, conforme norma. Com esses dados inseridos no EnergyPlus, foi possível dimensionar a carga térmica dos equipamentos de ar condicionado e seu desempenho energético, analisados através do COP anual simulado desses equipamentos. Com a simulação foi possível destacar os fatores que influenciam no consumo de energia de um sistema de ar condicionado no que diz respeito às condições climáticas, principalemente o impacto da temperatura externo no desempenho do equipamento. Nos resultados encontrados foi possível identificar que existe uma influência bastante significativa, principalmente quando se comparam regiões de alta temperatura externa e com de baixa temperatura externa e, em um segundo momento, valores altos e baixos de umidade relativa interna do ar ambiente, sendo que, altas umidades favorecem o desempenho do equipamento avaliado. Resultados bastante significativos foram encontrados na substituição de aparelhos Split fixo por aparelhos Split inverter, nos quais se alcançou uma redução de até 44% de economia em regiões específicas do país, seu COP anual simulado apresentou um indicador mais eficiente em todas as horas simuladas. / This work presents an analysis of the relationship between the performance of split, fixed and inverter air conditioning equipment for the air conditioning of a commercial building in the different Brazilian bioclimatic zones. Analyzes were performed by computer simulation using the EnergyPlus program. Eight cases followed by the reference model were simulated. The reference model adopted was created from a photographic survey of standard commercial buildings with more than four floors. From this survey, the typology that was adopted represents a ten-storey building with a perimeter of dimensions of 27 by 7.50 meters and, at the foot of 2.60 meters. In order to analyze the energy performance of the reference model, data were included on the building components, occupancy pattern, energy loads of the lighting system and equipment, air conditioning, with their respective performance curves, as supplier, and infiltration, according to norm. With these data inserted in the EnergyPlus, it was possible to measure the thermal load of the air conditioning equipment and their energy performance, analyzed through the simulated annual COP of this equipment. With the simulation, it was possible to highlight the factors that influence the energy consumption of an air conditioning system with regard to climatic conditions, mainly the impact of external temperature on the performance of the equipment. In the results, it was possible to identify that there is a significant influence, especially when comparing high temperature and external low temperature regions, and in a second moment, high and low values of internal relative humidity of the ambient air, high performance favors the performance of the equipment evaluated. Significant results were found in the replacement of fixed split devices with split inverter devices, in which a reduction of up to 44% of savings was achieved in specific regions of the country, its annual simulated COP showed a more efficient indicator at all simulated hours.

Page generated in 0.1316 seconds