Spelling suggestions: "subject:"air lightness"" "subject:"air brightness""
1 |
Tätskikt i klimatskal : En studie av byggentreprenörers arbetssättNilsson, Tim January 2013 (has links)
As energy prices skyrocket and the environmental issues become more frequently debated, interest in energy-efficient buildings has increased sharply in the past decade. Because of this, the interest to achieve high air tightness in building envelopes have once again awakened, due to a good air tightness contributes to lower energy consumption in several ways and to a healthier indoor environment. As the regulations for energy consumption and controls of achieved air tightness has tightened considerably in recent years, the work regarding sheets for air tightness changed significantly for construction contractors. This thesis includes a study that aims to detect what kind of manuals, recommendations or instructions contractors working according, and how a number of randomly selected construction companies in Halland, Sweden, are dealing with the matter of high air tightness of the building envelopes. The study also includes a knowledge inventory of supervisors, site managers and skilled workers, and what their opinions and attitudes are like towards work regarding the sheets of air tightness. The results have been compared with a similar survey dated to 2004, conducted by the SP Technical Research Institute of Sweden in collaboration with Chalmers University of Technology. The thesis provides a picture of the industry situation, but shouldn’t be seen as a statistical result due to its limited extent.
|
2 |
Achieving building energy performance : requirements and evaluation methods for residential buildings in Sweden, Norway, and FinlandAllard, Ingrid January 2015 (has links)
Building energy performance has always been important in the cold climate of Sweden, Norway and Finland. To meet the goal that all new buildings should be nearly zero-energy buildings by 2020, set in the EU directive 2010/31/EU [1] on the energy performance of buildings (EPBD recast), the building sector in Europe now faces a transition towards buildings with improved energy performance. In such a transition, a discussion is needed about the objective of the improvement – why, or to what end, the building energy performance should be improved. The objective of improving building energy performance is often a political decision, but scientific research can contribute with knowledge on how the objectives can be achieved. This thesis addresses how the indicators used in the requirements used to achieve building energy performance in Sweden, Norway, and Finland, and the methods used to evaluate these requirements, reflect building energy performance. It also addresses difficulties in achieving comparable and verifiable indicators in evaluations of building energy performance. The research objective has two parts: to review, compare, and discuss (i) requirements and (ii) evaluation methods used to achieve energy performance of residential buildings in Sweden, Norway and Finland. The work in this thesis includes reviews of the requirements used in national building codes and passive house criteria to achieve building energy performance, of methods used to evaluate compliance with such requirements, and of methods used specifically to evaluate the indicator Envelope Air Tightness. The results show that different sets of indicators are used to achieve building energy performance in the studied building codes and passive house criteria. The methods used to evaluate compliance with requirements used to achieve building energy performance are also different, but calculation methods are generally more often used than measurement methods. The calculation- and measurement methods used are often simple. A methodology to analyze the deviation between predictions- and measurements of building energy performance (the performance gap) was developed, to investigate the effects of different evaluation methods on different indicators used to achieve building energy performance. The methodology was tested in a case-study. This study indicated that the choice of method affects which parts of the performance gap reflected in the indicators Supplied Energy (see Terminology), Net Energy (see Terminology), and Overall U-value. Among the reviewed methods to evaluate air tightness, the Fan/Blower Door Pressurization is well known and preferred by professionals in the field. The results in this thesis may be useful when choosing indicators and evaluation methods to achieve different objectives of improving building energy performance and in the quest towards comparable and verifiable indicators used to achieve building energy performance. / Increasing Energy Efficiency in Buildings (IEEB) / Sustainable Buildings for the High North (SBHN)
|
3 |
Vliv volby vstupních parametrů zařízení Blowerdoor testu na výslednou hodnotu průvzdušnosti / Influence of choice of input parameters blowerdoor test equipment on the final value of air permeabilityKermes, Adam January 2013 (has links)
The thesis examines the influence of choice of input parameters Blowerdoor test equipment on the final value of air permeability. Measurements have been performed on a set of four experimental buildings and one room.
|
4 |
Lufttäthet och energiförbrukningi nyproducerade villor / Airtightness and energy consumption in newly produced villasSvensson, Jonathan, Lagerqvist, Felicia January 2023 (has links)
Uppvärmning inklusive varmvatten i lokaler står idag för 53 % av Sveriges totalaenergianvändning. För att uppnå en del av de uppsatta energi- och klimatmålen för EU ärenergieffektivt byggande en viktig nyckel. De kraftigt stigande elpriserna de senaste årenär en annan anledning att bygga mer energieffektiva byggnader. Idag dokumenterasenergiförbrukningen i en energideklaration som registreras hos Boverket för att ge entydlig bild av energianvändningen. Med hjälp av en lufttäthetsprovning där byggnadenutsätts för ett över- och undertryck på 50 Pa fås ett mått för hur mycket luft som läckergenom klimatskalet.Målet med arbetet är att undersöka hur energiförbrukningen i energideklarationen kansättas i korrelation till luftläckagevärdet. Med utgångspunkt ur villor producerade avEksjöhus som är lufttäthetsprovade från 2019 till 2023, har detta arbete jämfört statistikför att få fram en korrelationskoefficient. För att få en förståelse för hur Eksjöhus arbetatmed lufttäthet studerades utvecklingen av klimatskalet och luftläckagevärdet från 2012till 2022 via intervju och statistikarbete. För ett urval av lufttäthetsprovade hus byggdamellan 2019 och 2023 begärdes energideklarationer ut. Ett statistikarbete för data urenergideklarationer och luftläckagevärde genomfördes som är underlaget för diskussionoch analys av energideklarationens reliabilitet för att göra en översiktlig tolkning avresultatet tillförlitlighet.I intervjun med Eksjöhus framgår det att den enda förändringen som skett i klimatskaletsedan 2012 är att vägg-bjälklaget placerats en bit längre in för att underlätta att dra förbiplastfolie. Förändringen ger inte en synlig påverkan av det generella luftläckagevärdet.Eksjöhus har arbetat fram ett dokument som skickas med byggsatsen och fungerar som enguide för entreprenörerna för hur tätningar kring stålbalkar, genomföringar ochanslutningar ska göras. Eksjöhus använder sig även av en årlig träff tillsammans med deentreprenörer som bygger de flesta husen för att arbeta med lufttäthet. Vid arbetet medlufttäthet har Eksjöhus procentuellt minskat antalet nybyggda hus där luftläckagevärdetöverstiger de krav/riktlinjer företaget har.För att undersöka om luftläckage visar på ökad uppvärmd energi genomfördes enkorrelationsstudie där två variabler sätts i korrelation till varandra. Studien är tänkt attvisa att om ett hus läcker mycket luft kommer mängden energi som går åt till att värmaupp huset att öka. I jämförelse mellan luftläckage och uppvärmd energi visar inte studiennågot generellt samband.Arbetet tar inte hänsyn till byggnadernas specifika förutsättningar. Det leder till utebliveninformation kring levnadsvanor, antalet brukare och innetemperatur. I övrigt användesenbart energideklarationer från 103 samt 107 byggnader som deklarerats tidigast 1 januari2019. Provtryckningsresultat för att undersöka hur arbetet med lufttäthet för Eksjöhusnyproducerade villor utvecklats begränsas från 2012 till 2022. / This study investigating the correlation between energy consumption in energydeclarations and air leakage values, with a focus on Eksjöhus-produced villas. Tounderstand how Eksjöhus has been working with airtightness during 2012 to 2022 aninterview and an analysis of statistic has been done.The aim of this work is to investigate how the energy consumption documented in energydeclarations can be correlated with the air leakage obtained through an air leakage test.The results suggest that Eksjöhus implemented a solitary modification to the buildingenvelope since 2012, which did not significantly affect the overall air leakage values.During the period there was a proportional decrease in the number of new housesexceeding Eksjöhus requirements/guidelines for air leakage.No general correlation was found between energy consumption and air leakage. Whensorting data for low energy consumption and low air leakage a clearer correlation wasfound. The result also shows an economic advantage of constructing buildings with highairtightness.
|
5 |
MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : <em>Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metod</em>Sörensen, Ida January 2009 (has links)
<p>Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete:</p><p><em>Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt?</em></p><p>Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras.</p><p>Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m<sup>2</sup> till 0,4 l/s·m<sup>2</sup>. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes.</p><p>I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage.</p><p>De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat.</p><p>Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen.</p><p>Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat.</p> / <p>There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report:</p><p><em>Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units?</em></p><p>The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed.</p><p>The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m<sup>2</sup> to 0,4 l/s·m<sup>2</sup>. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study.</p><p>The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability.</p><p>The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results.</p><p>Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed.</p><p>A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.</p>
|
6 |
MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metodSörensen, Ida January 2009 (has links)
Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete: Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt? Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras. Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m2 till 0,4 l/s·m2. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes. I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage. De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat. Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen. Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat. / There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report: Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units? The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed. The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m2 to 0,4 l/s·m2. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study. The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability. The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results. Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed. A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.
|
7 |
Vliv intenzity tlakového namáhání plošných stavebních konstrukcí na hodnoty průvzdušnosti / Air permeability of the building structures according to artificial air pressure on the surfaceDvořák, Jan January 2014 (has links)
This thesis examines the influence of the intensity of pressure strain of structures printed on the value of air permeability. The measurement is carried out using Blower Door Test on six variants using OSB boards as airtightening layers in the building. Part of the research was to verify the suitability of the test chamber and measuring devices for similar purposes and adjustment chamber
|
8 |
Vzduchotěsnost obvodových konstrukcí a kritických detailů / Air tightness of building structures and critical detailsVávra, Petr January 2015 (has links)
In thesis is dealt with problematic of how the value of air permeability may be affected by properties for water vapour diffusion with regard to OSB material There were chosen two main brands of OSB at Czech trade market Two specimens of OSB with different thickness were chosen for each brand. As a first the specimens were tested for air tightness to work out a value of air permeability for each specimen. Afterwords, the testing was conducted for gaining properties of water vapour diffusion on each specimen. As a final assessment was analysed the impact of properties of water vapour diffusion on the air tightness for each specimen. The general meaning of gaining higher air tightness with higher water vapour resistance was proved . It was shown that with raising thickness is usually gotten higher value of water vapour diffusion resistance. However it could not mean getting high air tightness. The crucial parameter is the quality of the material for gaining higher resistance against water vapour diffusion as well as for higher airtightness.
|
9 |
Návrh opatření pro snížení energetické náročnosti prodejny potravin / Proposal of measures for reducing energy demands of food storesJulinová, Patricie January 2016 (has links)
The master thesis deals with measures to reduce energy performance of grocery store building. Model of the grocery store is evaluated according to a recommended energy values specified by Czech standards and according to the real values of the actual consumption. These values are compared. Final building analysis for a proposal measures to reduce energy consumption is based on the invoices of the real consumption and on the experimental assignments. Experimental measurements are the Blower door test of the tightness of the building envelope, the measures with the thermovision camera and the measuring of the illumination intensity. The most efficient proposal is extended to the whole model network of the food shops in the Czech Republic.
|
Page generated in 0.0675 seconds