• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 1
  • Tagged with
  • 67
  • 61
  • 27
  • 20
  • 15
  • 15
  • 12
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Evolução dos perfis elétricos e mecânicos da motilidade colônica em modelo animal de doença inflamatória intestinal

Calabresi, Marcos Felipe de Freitas. January 2017 (has links)
Orientador: José Ricardo de Arruda Miranda / Resumo: Inflammatory bowel disease (IBD) is an idiopathic gastrintestinal tract disease that affects a large part of the world population and has its symptoms related to changes in colon motility. However, the evolution of these changes is not completely understood, and may be related to symptoms that appear in stages when the disease is apparently controlled. The objective of this work was to perform a long-term evaluation of the mechanical and electrical aspects of colonic contractility during the model of inflammation induced by trinitrobenzene sulfonic acid (TNBS) in rats. This work applied an efficient and low invasive methodology associating mechanical, electrical, chemical and histological information. The contractility and inflammatory parameters were acquired in the same animal at six different times: before induction of TNBS (control) and at 2, 5, 8, 11 and 14 days thereafter. The mechanical activities were acquired by Alternating Current Biosusceptometry (ACB) and subdivided in Rhythmic Propagation Ripples (RPR) and Rhythmic Propulsive Motor Complex (RPMC). We recorded the electrical activity by electromyography (EMG) and evaluated the inflammation processes determining the myeloperoxidase activity (MPO) in the feces. Additionally, we compared the thickness of colon layers throughout the inflammation by histopathological analyzes. Our results showed transient changes in MPO activity levels and frequency of RPMC contraction, while RPR and electrical activity underwent perma... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
52

Estudo da inje??o de ?gua e CO2 em reservat?rio carbon?tico de ?leo leve

Diniz, Anthony Andrey Ramalho 10 August 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-05-03T23:46:47Z No. of bitstreams: 1 AnthonyAndreyRamalhoDiniz_TESE.pdf: 15099373 bytes, checksum: 616c247460cf0f6003f86c2374d07108 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-05-05T23:03:00Z (GMT) No. of bitstreams: 1 AnthonyAndreyRamalhoDiniz_TESE.pdf: 15099373 bytes, checksum: 616c247460cf0f6003f86c2374d07108 (MD5) / Made available in DSpace on 2016-05-05T23:03:00Z (GMT). No. of bitstreams: 1 AnthonyAndreyRamalhoDiniz_TESE.pdf: 15099373 bytes, checksum: 616c247460cf0f6003f86c2374d07108 (MD5) Previous issue date: 2015-08-10 / Em 2006, a Petrobras anunciou a descoberta do campo de Tupi, na Bacia de Santos, que concentra uma grande quantidade de petr?leo abaixo da camada de sal, conhecida como camada pr?-sal. Essa descoberta possui grandes volumes de ?leo leve (28? a 30? API), com alto conte?do de g?s, pr?xima aos centros consumidores mais importantes do Sudeste do Brasil e tendo os testes de forma??o dos primeiros po?os apresentado altas vaz?es, sem indica??o de barreiras. Apesar dessa descoberta ser muito importante, a Petrobras e seus parceiros reconhecem que ela representa um cen?rio desafiador, por estar localizada em torno de 300km da costa, em condi??es adversas para sua produ??o. Examinando poss?veis m?todos de recupera??o avan?ada aplic?veis ?quelas condi??es, considerou-se que a presen?a de di?xido de carbono (CO2) poderia ser vantajosa, se combinada com a ?gua do mar, no processo de inje??o alternada de ?gua e g?s (WAG), que passou a ser visto como uma boa op??o. Nesse contexto, esta pesquisa teve como objetivo a realiza??o da avalia??o de v?rias t?cnicas de inje??o de CO2 e ?gua, em reservat?rios com caracter?sticas do pr?-sal brasileiro. Para tanto, foi modelado um ?leo leve, semelhante aos ?leos encontrados na camada do pr?-sal, e um reservat?rio homog?neo, semissint?tico, tamb?m de caracter?sticas semelhantes aos reservat?rios carbon?ticos daquela regi?o, produzindo atrav?s de uma malha five-spot, em um tempo de projeto de 12 anos. Inicialmente, foram realizados testes injetando apenas ?gua e depois CO2. Com base nesses testes, foram avaliadas quatro varia??es do WAG, sendo as duas primeiras com inje??o alternada dos fluidos e as demais com inje??o cont?nua. Ao final, verificou-se que a inje??o alternada de ?gua e g?s, iniciada com ?gua, ? a op??o com maior recupera??o de ?leo, que alcan?ou 91,34% no melhor caso. Quando iniciado com inje??o de g?s, o mesmo processo se torna mais r?pido para intervalos mais curtos, mas n?o resulta na mesma efici?ncia. Por fim, os processos com inje??o cont?nua apresentam resultados mais r?pidos que a inje??o individual dos fluidos, mas o resultado final do CO2 ? superior.
53

Aplicação da técnica de eletrofloculação utilizando corrente alternada de frequência variável no tratamento de água de produção da indústria do petróleo / Variable frequency AC current aplied to the treatment of produced waters from the oil industry

Alexandre Andrade Cerqueira 07 January 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O principal objetivo da tese está relacionado ao tratamento de águas oleosas através da eletrofloculação utilizando corrente alternada de frequência variável, o qual procurou explorar as potencialidades desta técnica. Com a crescente demanda por petróleo e seus derivados, é cada vez maior a produção dessas águas residuárias que, antes de serem descartadas, precisam ser submetidas a tratamento que satisfaçam aos requisitos legais. O trabalho apresentado descreve o levantamento bibliográfico e os resultados dos ensaios realizados, empregando o tratamento de eletrofloculação com a finalidade de remover as substâncias consideradas poluentes presentes nestes efluentes. O processo de eletrofloculação foi testado tanto para o tratamento em corrente continua quanto em corrente alternada de frequência variável em efluentes sintéticos e reais de alta salinidade, contendo teores elevados de óleos e graxas, turbidez e cor. Eficiências de redução de 99% para óleos e graxas, cor e turbidez foram obtidos utilizando eletrodos de alumínio. O processo de eletrofloculação demonstrou-se bastante vantajoso em função da alta condutividade que permite o tratamento com menor consumo energético. A tecnologia de eletrofloculação com corrente alternada quando comparada com a tecnologia de corrente contínua se mostrou muito eficiente em relação a economia no desgaste de massa de eletrodos, o que, dependendo do tempo de aplicação da corrente elétrica nas mesmas condições de estudo, houve redução de mais da metade do consumo. / The main aim of the present work was to study the treatment of oil wastewaters using electroflocculation with AC and variable frequency and to explore the potentiality of the process. With the increasing demand for oil and its derivatives the production of oil wastewaters also increases. Before its final disposal, these undesirable wastewaters must undergo treatment to adjust its quality to legal requirements. The present work presents an extensive literature survey and the experimental results obtained can be deemed as excelent, as reduction efficiencies of about 99% of the main quality parameters, namely, oils and greases, turbidity and colour, were obtained. The process was carried out using both direct and variable frequency alternate currents in high salinity samples of both real and synthetic wastewater. containing high levels of oil and grease, turbidity and color. Reduction efficiencies of 99% for oils and greases, color and turbidity were obtained using aluminum electrodes. The process electroflocculation seem to be quite advantageous due to the the fact that high conductivity values result in considerably low energy consumption. Electroflocculation processes using AC , as compared with similar processes, proved to very efficient, mainly because of its potential economy in mass of electrodes, which, depending on the time of application of electric current in the same conditions of study, a reduction of more half the consumption was obtained.
54

Propriedade Alternada do Operador de Dirichlet-Neumann

Silva, José Eduardo Jesus da 22 July 2010 (has links)
Made available in DSpace on 2015-05-15T11:46:24Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 947145 bytes, checksum: 7294f81daf663930a60afca1aecbee7b (MD5) Previous issue date: 2010-07-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work we talk about properties of the Dirichlet-to-Neumann map for the conductivity equation in a smooth manifold with boundary of R2. We use several times the Maximum Principle to conclude a Alternating Property of the Dirichlet-to- Neumann map. Using this property, we and that the Kernel satises a given set of inequalities. Finally, we note that these inequalities imply the Alternating Property of the Kernel of the Dirichlet-to-Neumann map. / Neste trabalho dissertamos sobre Propriedades do Funcional de Dirichlet-Neumann para uma equação de condutividade numa variedade diferenciavel bidimensional com bordo. Utilizamos varias vezes o Principio do Maximo para concluir que esse Funcional tem uma Propriedade Alternada. A partir dessa propriedade, verificamos que o Nucleo do Funcional satisfaz um conjunto especifico de desigualdades. Porém, verificamos que essas desigualdades implicam na Propriedade Alternada do Nucleo do Funcional.
55

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
56

Efeito hipoalgésico da corrente alternada de média frequência em quilohertz (Aussie) em indivíduos saudáveis: ensaio clínico randomizado

Agripino, Mayara Ellen de Jesus 03 March 2017 (has links)
Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE / Studies report that alternating current is more effective in promoting analgesia than low frequency pulsed currents. However, the hypoalgesic potential and the clinical use of the medium frequency alternating current in kHz (Aussie) are based on hypothetical mechanisms of action. The present study aimed to investigate the hypoalgesic potential of the Aussie Current (AC) in healthy individuals. Eighty-one healthy subjects underwent electrostimulation by using kilohertz-frequency alternating current for 20 minutes and were randomized into three distinct groups (1 kHz, 4 kHz or placebo). Pressure pain threshold (PPT, algometry), conditioned pain modulation (CPM, ischemic pain in the contralateral upper limb and algometry), temporal summation (TS, algometry) were measured before and after intervention, the level of anxiety (STAI-T and STAI-E), in turn, was measured only at the pre-intervention. At the end of the protocol, subjects were questioned regarding the treatment they received and the comfort during the stimulation (numerical scale) and, similarly, investigators were questioned about their expectation related to subject’s allocation groups. These responses were recorded and used to test the adequacy of the masking procedure regarding the subject and the investigator. The level of anxiety evaluated did not a statistically significant difference between the groups, who received the active AC (1 kHz / 4kHz) or placebo, (p> 0.05). Regarding PPT, there was no statistically significant difference in the active AC 1 kHz, active 4 kHz and placebo groups at any of the moments evaluated. The active group AC 4 kHz presented a statistically significant reduction in the amplification of pain intensity, verified by the reduction of perceived pain intensity, in the tenth (p = 0.02), twentieth (p = 0.01) and thirtieth second (p = 0.001) in the TS test. The active group AC 1 kHz, in turn, presented significant reduction of pain intensity only at the end of the measurement (thirty-second, p = 0.01). In the evaluation of the CPM, there was no significant difference of the PPT, during induction of ischemia, in the AC active groups 4 kHz and active AC 1 kHz, before and after intervention (p> 0.05). However, in the placebo group there was a significant reduction in PPT, only during induced ischemia, both before and after intervention (p = 0.01). Thus, our study provides evidence that kilohertz-frequency AC current, especially when used with an equivalent 4 kHz frequency, presents hypoalgesic effect, having having possible inhibitory action in the Central Nervous System (CNS). / Estudos relatam que a corrente alternada é mais eficaz em promover analgesia que as correntes pulsadas de baixa frequência. Porém, o potencial hipoalgésico e a utilização clínica da corrente alternada de média frequência em kHz (Aussie) são baseados em mecanismos de ação hipotéticos. O presente estudo teve, como objetivo, investigar o potencial hipoalgésico da corrente Aussie (CA) em indivíduos saudáveis. Oitenta e um sujeitos saudáveis foram submetidos à eletroestimulação com corrente alternada de média frequência em quilohertz durante 20 minutos, sendo randomizados em três grupos distintos (1 kHz, 4 kHz ou placebo). Limiar de dor por pressão (LDP, algometria), modulação condicionada da dor (MCD, dor isquêmica no membro superior contralateral e algometria), somação temporal (ST, algometria) foram mensurados antes e após intervenção, o nível de ansiedade (IDATE-T e IDATE-E), por sua vez, foi mensurado apenas no momento pré-intervenção. Ao final do protocolo, os sujeitos foram questionados com relação ao tratamento que receberam e o conforto durante a estimulação (escala numérica) e, similarmente, os avaliadores sobre sua expectativa relacionada ao grupo de alocação dos sujeitos. Estas respostas foram registradas e usadas para testar a adequação do procedimento de mascaramento referente ao sujeito e ao investigador. O nível ansiedade, avaliado no momento pré-intervenção, não diferiu entre os grupos que receberam a CA ativa (1 kHz/ 4 kHz) ou placebo, sendo p>0,05. Em relação ao LDP, não houve diferença estatisticamente significativa nos grupos de intervenção CA ativa 1kHz, ativa 4 kHz e placebo em nenhum dos momentos avaliados. O grupo ativo CA 4 kHz apresentou redução estatisticamente significativa da amplificação da intensidade da dor, verificada pela redução da intensidade de dor percebida, no décimo (p=0,02), vigésimo (p=0,01) e trigésimo segundos (p=0,001), no teste de ST. O grupo ativo CA 1 kHz, por sua vez, apresentou redução significativa da intensidade de dor apenas no final da mensuração (trigésimo segundo; p=0,01). Na avaliação da MCD, não houve diferença significativa do LDP, durante a indução de isquemia, nos grupos CA ativo 4 kHz e CA ativo 1 kHz, no momento antes e após intervenção (p>0,05). No entanto, no grupo placebo, houve redução significativa do LDP, apenas durante a isquemia induzida, comparando pré e pós-intervenção (p=0,01). Dessa forma, o nosso estudo, fornecem evidências de que a corrente aussie, principalmente, quando utilizada com frequência equivalente 4 kHz, apresenta resultados hipoalgésicos, tendo possível ação inibitória no sistema nervoso central (SNC).
57

Modelagem computacional do aquecimento de um motor de indução monofasico aplicado em maquinas de lavar roupas durante a etapa de agitação / Computer based model for the heating of a single phase induction motor applied on washing machine during agitation task

Giesbrecht, Mateus, 1984- 11 September 2007 (has links)
Orientador: Gilmar Barreto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-09T16:50:00Z (GMT). No. of bitstreams: 1 Giesbrecht_Mateus_M.pdf: 3904732 bytes, checksum: 55e43903b08b7c8d770f9120fb071c40 (MD5) Previous issue date: 2007 / Resumo: A motivação para este estudo é criar um modelo computacional capaz de prever se o regime de trabalho a que um motor monofásico de indução é submetido implica ou não em um aquecimento que comprometa os materiais isolantes do mesmo. A solução apresentada busca encontrar uma equação a diferenças em que a saída do sistema (temperatura do motor no instante k+1) é calculada como uma combinação linear das entradas (temperatura do motor, valor RMS da corrente e temperatura ambiente no instante k). Para conhecer os coeficientes desta combinação linear, foram realizados alguns ensaios e, a partir de seus resultados, foi aplicado o método dos mínimos quadrados para a obtenção do modelo computacional que representa o sistema. Os resultados computacionais obtidos com o modelo proposto refletem com exatidão o comportamento do sistema real. O modelo desenvolvido também é útil para outras aplicações em que se utilize um motor de indução monofásico em regime intermitente periódico com partida / Abstract: This study motivation was finding a computer-based model that was able to foresee if the duty cycle applied in a single-phase induction motor implies or not in an overheating that can compromise the motor insulation. The solution presented here is based on finding a difference equation in which the system output (motor temperature at time k+1) is calculated as a linear combination of the input (motor temperature, RMS current and ambient temperature at time k). The Mean Square Method was applied to find the coefficients of this linear combination, resulting in the final computational model that represents the system. The computational results found with the proposed model reflect exactly the real system behaviour. This model is also useful to other applications in which a single-phase induction motor during intermittent periodic duty with starting is used. / Mestrado / Automação / Mestre em Engenharia Elétrica
58

ESTUDO EXPLORATÃRIO DA SOLDAGEM MIG/MAG COM DUPLO ARAME EMPREGANDO CORRENTE ALTERNADA / Exploratory Study of tandem GMA welding applying alternating current

Edson Frota Pessoa 25 June 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho teve como objetivo o estudo exploratÃrio do processo MIG/MAG-DA-PI utilizando corrente alternada. Os ensaios foram executados em simples deposiÃÃo na posiÃÃo plana em chapas de aÃo baixo carbono com espessura de 3 mm utilizando arame eletrodo de 1,2 mm de diÃmetro. Foram realizados estudos sobre o nÃvel de corrente, tipo de onda aplicado em corrente alternada (CA-CP e CA-CC), a porcentagem de corrente alternada com o eletrodo na polaridade negativa (% CAEN), o sentido de deslocamento do eletrodo em relaÃÃo ao tipo de onda. Foi realizado tambÃm um estudo comparativo entre as soldagens realizadas em corrente alternada com corrente pulsada e sobre a disposiÃÃo dos eletrodos em relaÃÃo à direÃÃo de soldagem (âtandemâ e lado a lado). Foram avaliados os efeitos destes estudos nas caracterÃsticas geomÃtricas (penetraÃÃo, reforÃo e largura), na diluiÃÃo, na taxa de fusÃo do arame eletrodo, no aspecto superficial do cordÃo de solda e na microestrutura resultante na regiÃo de grÃos grossos da zona afetada pelo calor. Foi constatado que o aumento no nÃvel de corrente promove o aumento nas caracterÃsticas geomÃtricas, da diluiÃÃo e da taxa de fusÃo. A aplicaÃÃo de corrente alternada na soldagem MIG/MAG-DA-PI promoveu o aumento da taxa de fusÃo do arame, do reforÃo com a diminuiÃÃo da diluiÃÃo e da largura do cordÃo de solda. O aumento da % CAEN resultou no aumento do reforÃo, da taxa de fusÃo do arame, reduÃÃo da largura, da diluiÃÃo da solda e no refino da microestrutura. A aplicaÃÃo de corrente alternada no eletrodo anterior promoveu a reduÃÃo da diluiÃÃo com o aumento do reforÃo. Em comparaÃÃo com o uso da corrente pulsada, aplicaÃÃo de corrente alternada no processo MIG/MAG-DA-PI, para um mesmo nÃvel de corrente eficaz, resultou no aumento do reforÃo, da taxa de fusÃo do arame com a diminuiÃÃo da largura e da diluiÃÃo da solda. / The use of alternating current (or variable polarity) on the tandem GMAW process was investigated experimentally. Bead-on-plate test, in flat position, were carried out using a 1.2 mm diameter on mild steel sheet (3mm-thick). The level of welding current, waveform type applied in alternating current tandem GMAW: alternating-continuous current (AC-CC) and alternating-pulsed current (AC-PC), the percentage of alternating current in the negative polarity (% DCEN), the displacement direction of electrode applied related to waveform type. It was also carried out a comparative study between variable polarity and pulsed current in tandem GMAW and, a comparative study about the arrangement of electrodes in respect to the welding direction (tandem and side-by-side). The effects on welding geometric characteristics (penetration, reinforcement and width), weld dilution, electrode fusion rate and microstructure on coarsened grain heat affected zone (CG-HAZ) were evaluated. The experiments revealed that as current level increase, the geometrics characteristics, dilution and electrode fusion rate increased accordingly. The application of variable polarity in tandem GMAW process resulted in an increase on electrode fusion rate, reinforcement and, reduction of dilution and width of weld bead. Increasing % DCEN resulted in increase reinforcement and electrode fusion rate, reduction of dilution and width and, a refinement of microstructure. By applying variable polarity waveform on the trailing electrode, dilution is reduced and reinforcement is increased. Comparing welds made with pulsed current, the use of variable polarity in tandem GMAW process resulted in increase of reinforcement, electrode fusion rate and, reduction of width and dilution.
59

Transmissão de energia elétrica em meia-onda e em corrente contínua - análise técnico-econômica. / Half wave-length power transmission and HVDC power transmission - a technical and eponomical analysis.

Santos, Milana Lima dos 19 March 2012 (has links)
Ao buscar alternativas para interligação entre importantes centros de geração de energia elétrica localizados no Norte do Brasil e centros consumidores no Nordeste e Sudeste, o setor elétrico brasileiro se depara com o desafio de transpor distâncias superiores a 2000 km. A alternativa em corrente contínua já é bastante utilizada, com desempenho satisfatório. Já a transmissão em meia-onda, ainda não utilizada comercialmente em país algum do mundo, é uma alternativa sugerida por alguns artigos como adequada a esse propósito. Este trabalho se propõe a apresentar uma metodologia de comparação econômica entre alternativas de transmissão e aplicá-la à comparação entre a meia-onda e a corrente contínua, utilizando um cenário muito próximo ao brasileiro. Para possibilitar esta comparação, são apresentados detalhes do funcionamento da linha de meia-onda, já que pouco foi publicado sobre o assunto. São mencionados alguns aspectos adversos de seu comportamento transitório e também são descritas etapas de definição de alternativas de transmissão a serem avaliadas. / In order to connect important power generation plants located in Northern region to the major load centers in the Northeast and Southeast parts of the country, the Brazilian electric sector should deal with the challenge of planning transmission systems to cover distances of more than 2000 km. The HVDC transmission alternative, which has shown satisfactory response and performance to also carry bulk power over long distances, is already used in many countries. Still, the half-wavelength power transmission line (HWLL), not yet commercially used in any country, is an alternative suggested by some papers as suitable for this purpose. Thus, the objective of this work is to present a methodology for the economic comparison amongst the transmission alternatives present today, to thereafter apply it to the HWLL and HVDC transmission technologies. To do so, a closest scenario to that of the Brazilian case will be used. In order to perform this comparison, some details of the HWLL operation are explored, since little was published on this subject. Also, some adverse aspects of the HWLL transient behavior as well as the steps for defining the transmission alternatives to be evaluated are presented.
60

Planejamento de sistemas de transmissão em área com fonte de geração intermitente, apoiado no uso de tecnologias avançadas. / Planning of transmission systems in an area with an intermittent generation source, based on the use of advanced technologies.

Silveira, Patrícia Oliveira da 02 May 2017 (has links)
O Brasil é um país de dimensões continentais, onde existe uma considerável distância entre a geração e os principais centros de consumo. Dessa forma, o estudo e desenvolvimento de novas tecnologias de transmissão a longas distâncias é de fundamental importância para o desenvolvimento do país. A solução mais utilizada atualmente é a transmissão em corrente alternada. Entretanto a transmissão em corrente continua também é uma solução viável para longas distâncias. O sistema brasileiro é composto principalmente por linhas 500 kV em corrente alternada (também há 230; 345; 440 e 750 kV), bem como em corrente continua (em ±600 e ±800 kV). O presente estudo apresenta uma solução de transmissão em corrente alternada por linhas de 1000 kV, que se mostrou mais econômico na transmissão de potências superiores a 3.500 MW e distâncias de 1400km. Nos próximos anos, a geração de energia elétrica no Brasil será expandida de forma significativa, ocorrerá um aumento principalmente na geração de energia eólica e solar, localizadas em sua maioria na região Nordeste do país. Esse aumento na geração exigirá a transmissão de grandes blocos de energia elétrica por distâncias significativas, devido à falta de proximidade entre a geração e os principais centros consumidores, que estão localizados no Sudeste. Neste estudo, serão mostradas as etapas de definição de condutor economicamente mais adequado e projeto da geometria da torre. Com base nos dados obtidos, será feita a avaliação do desempenho da linha 1000 kV, durante a operação normal de fluxo de carga, curtos-circuitos e estabilidade. / Brazil, a country of continental proportions, have significant distance between the power generation centers and the main consumer centers. In such way, the study and development of new transmission technologies over long distances is of fundamental importance for the development of the country. Nowadays, the most commonly used solution is alternating current transmission. However, direct current transmission is also a viable solution for long distances. The Brazilian system mainly consists of 500 kV alternating current lines (along with 230, 345, 440 and 750 kV) and direct current lines (± 600 and ± 800 kV). This study provides a solution for transmission in alternating current by lines of 1000 kV, which proved to be more economical in power transmission over 3,500 MW and distances beyond 1400km. In the coming years, the electric power generation in Brazil will expand significantly; a boost will take place mainly in wind and solar power generation, located mostly in the Northeast of the country. This generation expansion will require transmission of large blocks of electric power over considerable distances, due to the lack of proximity between generation sites and main consumer centers located in the Southeast. This study will show the setting stages of the most economically applicable conductor and tower geometry design. Based on the data obtained, the performance of the 1000 kV line will be evaluated during the regular load flow operation, short circuits and stability.

Page generated in 0.2354 seconds