• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 96
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 5
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 99
  • 99
  • 48
  • 40
  • 40
  • 28
  • 24
  • 24
  • 23
  • 22
  • 22
  • 22
  • 20
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação cefalométrica das alterações dentoesqueléticas e tegumentares em jovens com má oclusão de classe II tratados com distalizadores Distal Jet / Cephalometric evaluation of dentoskeletal and soft tissue changes in young individuals with class II malocclusion treated with Distal Jet distalizers

Rachelle Simões Reis Lopes 12 March 2007 (has links)
A proposta deste estudo consistiu em avaliar, por meio de telerradiografias em norma lateral, as alterações dentoesqueléticas e tegumentares promovidas pelo aparelho distalizador intrabucal Distal Jet. A amostra foi composta por 44 pacientes, divididos em dois grupos. O grupo 1, experimental, constituí-se de 22 pacientes, 5 do gênero masculino e 17 do feminino, com má oclusão de Classe II, sendo que, 72,72% apresentavam ½ Classe II, 18,18% ¼ de Classe II e 9,09% ¾ de Classe II. A idade inicial variou entre 10,54 anos e 14,77 anos (média de 12,71 anos). Estes pacientes receberam o tratamento com o distalizador intrabucal Distal Jet, por um período médio de 1,20 anos. O grupo 2, controle, composto por 22 pacientes, 13 do gênero masculino e 9 do feminino, com idade ao início da observação variando entre 11,03 e 14,63 anos (média de 12,27 anos), apresentava má oclusão de Classe II não tratada, e foram observados por um tempo médio de 1,18 anos. Realizou-se a compatibilização dos grupos de acordo com a idade, tempo de tratamento/observação, severidade da má oclusão e variáveis cefalométricas iniciais. Utilizou-se o teste t de student, para amostras independentes, a fim de se comparar as idades iniciais e finais, tempo de tratamento/observação, variáveis iniciais cefalométricas e alterações médias reais na comparação intergrupos. A severidade da má oclusão entre os grupos foi analisada pelo teste do Qui-quadrado. Para avaliar as alterações iniciais e finais dentro do grupo experimental, realizou-se o teste t para amostras dependentes. O distalizador Distal Jet não alterou o posicionamento ântero-posterior da maxila e mandíbula, entretanto, provocou um aumento no padrão de crescimento facial decorrente da alteração significante do ângulo do plano mandibular (FMA). Os primeiros molares superiores apresentaram uma distalização significante, porém, não sofreram uma inclinação distal e extrusão estatisticamente significantes. Os segundos molares superiores inclinaram-se distalmente, extruíram e distalizaram significantemente. O efeito recíproco do Distal Jet, sobre a unidade de ancoragem, promoveu uma significante vestibularização e protrusão dos incisivos superiores, bem como uma mesialização dos primeiros pré-molares superiores, repercutindo no aumento do overjet. Não ocorreram alterações significantes na extrusão dos primeiros pré-molares e incisivos superiores, no overbite e no perfil facial. / This study evaluated the dentoskeletal and soft tissue changes promoted by the intraoral distalizer Distal Jet, by analysis of lateral cephalograms. The sample was composed of 44 patients, divided into two groups, as follows. Group 1 (study group) was composed of 22 patients, being 5 males and 17 females, with Class II malocclusion, among which 72,72% exhibited ½ Class II, 18,18% ¼ Class II, and 9,09% ¾ Class II. The initial age ranged from 10,54 years to 14,77 years (mean 12,71 years). These patients were treated with the intraoral distalizer Distal Jet for a mean period of 1,20 years. Group 2 (control group) comprised 22 patients, being 13 males and 9 females, aged 11,03 to 14,63 years (mean 12,27 years) at the onset of follow-up, presenting with untreated Class II malocclusion, who were followed for a mean period of 1,18 years. The groups were rendered compatible as to age, period of treatment/observation, severity of malocclusion and initial cephalometric variables. The Student t test for independent samples was applied to compare the initial and final ages, period of treatment/observation, initial cephalometric variables and actual mean changes in the comparison between groups. The severity of malocclusion between groups was analyzed by the chi-square test. The initial and final changes for the study group were evaluated by the t test for dependent samples. The Distal Jet distalizer did not change the anteroposterior positioning of maxilla and mandible, yet promoted an increase in facial growth pattern due to a significant change in mandibular plane angle (FMA). The maxillary first molars exhibited significant distalization, yet did not present statistically significant distal inclination and extrusion. The maxillary second molars presented significant distal inclination, extrusion and distalization. The reciprocal effect of Distal Jet on the anchorage unit promoted significant buccal tipping and protrusion of maxillary incisors, as well as mesialization of the maxillary first premolars, leading to an increased overjet. There were no significant changes in the extrusion of maxillary first premolars and incisors, overbite and facial profile.
42

Estudo comparativo da degradação de forças geradas por elásticos ortodônticos sintéticos e molas de níquel-titânio /

Araujo, Fabiana Ballete de Cara. January 2006 (has links)
Orientador: Weber José da Silva Ursi / Banca: Robert Chaib Stegun / Banca: Carlos Alberto Adde / Banca: João Batista Macedo Becker / Banca: Lúcia Teramoto / Resumo: Analisaram-se separada e comparativamente três marcas comerciais de elásticos ortodônticos sintéticos e de molas de NiTi (MORELLI, ORMCO e GAC), quanto à degradação da força sofrida por estes materiais em função do tempo, quando submetidos a simulação das condições bucais. Os elásticos e molas foram inicialmente termociclados (temperaturas de 15°C e 45°C), em seguida estirados em 20mm, imersos em saliva artificial a 37°C e desativados em 0,5mm semanais. As leituras da quantidade de força gerada pelas amostras foram realizadas nos momentos: inicial, 1, 24, 48 horas, 7, 14, 21 e 28 dias. Observou-se significativa redução na quantidade de força gerada pelos elásticos na primeira hora de ativação, que variou de 49,5% a 53%, enquanto que para as molas a degradação foi signicativamente menor, com valores entre 4,2% e 18,1%. Ao término de 28 dias de testes, as amostras de elásticos sofreram redução média na quantidade de força gerada entre 82,7% e 91,2% (GAC-82,7%, ORMCO-86,0% e MORELLI- 91,2%) já as amostras de molas apresentaram degradação média de força entre 17,5% e 32,2% (MORELLI-17,5%, ORMCO-27,3% e GAC-32,2%). Concluiu-se que, em geral, os elásticos promoveram maior índice inicial de força que as molas, mas após as primeiras 24 horas de ativação a quantidade de força gerada pelos elásticos era menor que a promovida pelas molas, que assim apresentaram níveis médios de força mais constantes que os elásticos ao longo dos testes. / Abstract: Three commercial marks of synthetic elastics and NiTi coil springs (MORELLI, ORMCO, GAC) were separately and comparably analyzed, according to the force degradation generated by these materials, because of the time, when maintained stretched in artificial salivary, 37°C. The synthetic elastics and NiTi coil springs were thermal- cycled (15°C-45°C) and stretched in 20mm, and this stretch was reduced in 0,5mm weekly. The readings of the amount generated for elastics and coil springs were done in the intervals 0, 1, 24, 48h, 7, 14, 21 and 28 days. Where observed significative reduction on the amount of force generated for the elastics in the first hour of the activation (49,5%- 53%), and 82,7% - 91,2% in 28 days of the tests ( MORELLI - 91,2%, ORMCO - 86,0%, GAC - 82,7%);, while the generated force for NiTi coil springs suffered a reduction of 4,2%- 18,1%, in the first hour of the experimentation and 17,5% - 32,2% in 28 days of the stretch (MORELLI - 17,5%, ORMCO - 27,3%, GAC - 32,2%). We conclude that for most elastics delivered larger initial force that NiTi coil springs, but after 24 hours of activation the NiTi coil springs delivered larger force that the elastics and generated level of the force more constant that elastics. / Doutor
43

Modulação da virulência de biofilmes de Streptococcus mutans por íons metálicos liberados de aparelhos ortodônticos / Alinne Ulbrich Mores Rymovicz ; orientador, Edvaldo Antônio Ribeiro Rosa

Rymovicz, Alinne Ulbrich Mores January 2011 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2011 / Inclui bibliografias / Introdução: Íons metálicos são continuadamente liberados a partir de ligas metálicas de aparelhos ortodônticos fixos. A modulação de virulência de biofilmes de Streptococcus mutans por íons metálicos oriundos de aparelhos ortodônticos ainda é incerta. Est / Introduction: Metal ions are continuously released from orthodontic appliance alloys. However, the effect of these ions on the virulence of Streptococcus mutans biofilms is unknown. In the present study, we evaluated the impact of metal ions commonly shed
44

Análise de elementos finitos da ação do aparelho extrabucal e seus efeitos nos dentes e no ligamento periodontal / Ivan Toshio Maruo ; orientador, Orlando Tanaka

Maruo, Ivan Toshio January 2011 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2011 / Inclui bibliografias / Introdução: Esta pesquisa objetivou desenvolver um modelo preciso, que permita simular a ação do Aparelho Extrabucal (AEB) e, por meio da Análise de Elementos Finitos, avaliar a mecânica do sistema. Métodos: Fatias tomográficas de uma maxila humana com de / Introduction: This study aimed to develop an accurate model, that permits the simulation of the headgear appliance (HG) action and, through the Finite Element Analysis, to assess the system mechanics. Methods: Tomographic slices of a human maxilla with co
45

Modulação da virulência de biofilmes de candida albicans por íons metálicos comumente liberados de aparelhos ortodônticos / Maiara Medeiros Ronsani ; orientador, Edvaldo Antonio Ribeiro Rosa

Ronsani, Maiara Medeiros January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Inclui bibliografias / Introdução: A instalação de aparelhos ortodônticos metálicos consequentemente leva a um aumento na concentração salivar de íons metálicos e de Candida spp. Contudo, nenhuma relação entre ambas, em termos de virulência, foi anteriormente estudada. O obje / Introduction: The installation of metal devices leads to an increase in the salivary concentration of metal ions and in the growth of salivary Candida spp. However, the relationship between released metal ions and Candida virulence has not been previously
46

Resistência adesiva ao cisalhamento de brackets cerâmicos monocristalinos : estudo in vitro / Luís Filipe Siu Lon ; orientador, Olilon Guariza Filho

Lon, Luís Filipe Siu January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. 35-38 / Introdução: A crescente procura por tratamentos ortodônticos pelos adultos em busca de correção da oclusão e estética, tem aumentado a demanda no uso de rackets cerâmicos. O objetivo deste trabalho foi avaliar, in vitro, a Resistência Adesiva (RA) ao cisa / Abstract: The purpose of this study was to evaluate the Shear Bond Strength (SBS) and the adhesive failure mode of Radiance® (American Orthodontics, Sheboygan, Wisc) and Inspire Ice® (ORMCO, Orange, Calif) monocrystalline ceramic brackets and compare them
47

Influência do condensado de fumaça de cigarros na formação de biofilmes de Streptococcus mutan e Candida albicans em materiais ortodônticos = Influence of cigarette smoke condensate on cariogenic and candidal biofilm formation upon orthodontic materials / Fernanda Brasil Baboni ; oreintador, Edvaldo Antonio Ribeiro Rosa ; co-orientadores, Odilon Guariza Filho, Andréa Novais Moreno / Influence of cigarette smoke condensate on cariogenic and candidal biofilm formation upon orthodontic materials

Baboni, Fernanda Brasil January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. 46-50 / Introdução: Analisamos experimentalmente a capacidade de aderência e de formação do biofilme de Streptococcus mutans 6715 e de Candida albicans SC5314 na superfície de materiais ortodônticos na presença do ondensado de fumaça de cigarros (CFC). Métodos: B / Abstract: Introduction: An experimental analysis was made in order to quantify the adherence rates and biofilm formation capacity of Streptococcus mutans 6715 and Candida albicans SC5314 on orthodontic material surfaces in the presence of cigarette smoke
48

Proteção catódica em aparelhos ortodônticos visando diminuir a liberação de níquel

Flach, Miguel Afonso January 2015 (has links)
A ortodontia pressupõe o uso de artefatos. Os bráquetes são ligados por fios ortodônticos, denominado arcos, para que possam ser movimentados juntamente com os dentes por sistemas de molas e ancoragens de vários materiais unidos por diferentes processos. Isto propicia uma pilha galvânica e liberação de níquel pelo aparelho. Atualmente existem materiais livres de níquel, porém os aços inoxidáveis possuem menor custo e maior facilidade de uso. A alergia ao níquel contido no aço inoxidável do aparelho causa desconforto e, em alguns casos, a interrupção do tratamento. Tal alergia provém dos íons de níquel liberados pelo aço inoxidável e transportados pela saliva até os tecidos do paciente. Este trabalho teve por objetivo aplicar a técnica dos anodos de sacrifício utilizada para a proteção catódica de estruturas metálicas expostas a meios salinos. Esta técnica foi aplicada na proteção do aço inoxidável e suas combinações com outros metais usados em tratamentos ortodônticos. Foram efetuadas várias combinações de anodos de sacrifício e eletrólitos em duas etapas de testes, com arranjos compostos por uma banda soldada com solda prata a um meio arco pré-contornado mais cinco bráquetes presos nele por um fio de amarril. Na primeira etapa foram avaliados quatro anodos de sacrifício amarrados aos arranjos e soluções aquosas com três salinidades obtendo-se em torno de cinquenta por cento de redução na liberação de níquel. A segunda etapa foi melhor sucedida e, a quantidade de níquel liberada, ficou abaixo do limite de detecção do equipamento de absorção atômica eletroquímica que foi utilizado neste trabalho. Nessa segunda etapa foram utilizados anodos de zinco e magnésio para a proteção e soro fisiológico com e sem fluoreto de sódio. O contato elétrico dos anodos de sacrifício com o aço inoxidável foi melhorado e, possivelmente, causou a menor liberação de níquel nesta etapa. Isto valida o método de proteção catódica na diminuição da liberação de níquel pelos aparelhos ortodônticos de aço inoxidável. / Orthodontics involves the use of artifacts. The orthodontic brackets are connected by wires, called arches, so that they can be moved together with the teeth by springs and anchoring systems of different materials together by different processes. This possibly creates a galvanic cell, and release of nickel by the device. Currently there are nickel-free materials. However stainless steels have lower value and ease of use. Allergy to nickel contained in the stainless steel unit causes discomfort and in some cases to discontinuation of treatment. This allergy comes from nickel ions released by stainless steel through the patient's saliva. This study aimed to apply the technique of sacrificial anodes used for cathodic protection of steel structures exposed to saline. This technique was applied to the stainless steel protection and their combinations with other metals used in orthodontic treatments. Various combinations of sacrificial anodes and electrolytes were made. Two stages of tests were carried out and arrangements consist of a welded band with silver solder in the middle pre-skirted five brackets bow stuck in it with amarril wire. In the first stage were evaluated four anodes sacrifice tied to the arrangements and aqueous solutions with various salinities yielding around fifty percent reduction in nickel release. The second step was more successful and the amount of nickel released, was below the detection limit of electrochemical atomic absorption device used in this work. In the second stage we used zinc and magnesium anodes for the protection and saline with and without sodium fluoride. The electrical contact of sacrificial anodes with stainless steel has been improved and possibly caused the lower nickel release at this stage. This validates the method of cathodic protection in the reduction of the release of nickel stainless steel orthodontic appliances.
49

ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS / Comparative study of angulation and inclination of different brackets trademarks

Zanesco, Alexandre 27 April 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 / The purpose of this study was to compare the angulations and torques of orthodontic brackets from different trademarks in relation to the Roth s prescription and also in relation with the recommended values from the manufacturer. It was used 150 orthodontic metalic stainless steel brackets, from upper cuspid and incisors in its prescription and evaluated through a vertical Benchtop Measuring Projector in the Metrology laboratory of Dental Morelli Ltda. After collecting the results and the application of statistical test, it was obtained that values of torque found with the Roth´s prescription was similar between the manufacturer and the cuspid angulation has been shown higher values in comparison to that proposed from the author in the manufacturer Morelli, and for the teeth 2.1 and 2.2, the increased angulation was showed on Abzil manufacturer s bracket. On comparative values of torque obtained within all manufacturers, Unitek showed greater reliability in torque values than others. For angulation, the reliability of the same manufacture was not superious when compared to the other manufacturers. It was concluded that the differences on both torque and angulation to the author values and prescription of the manufacturers studies fall within the degree of advocated tolerance by a German association of orthodontic accessories. / O objetivo deste estudo foi comparar as angulações e torques de braquetes de marcas comerciais distintas em relação à prescrição de Roth e também em relação aos valores preconizados pelo fabricante. Foram utilizados 150 braquetes metálicos de aço inoxidável, de caninos e incisivos superiores na respectiva prescrição, avaliadas por meio de um perfilômetro. Após a coleta dos dados e aplicação do tratamento estatístico, os resultados demonstraram que os valores de torque obtidos com a prescrição de Roth foram semelhantes entre os fabricantes. Na angulação, os caninos superiores apresentaram valores acima do proposto pelo autor para o fabricante Morelli, e para os dentes 21 e 22, a angulação foi maior para o fabricante Abzil. Na comparação dos valores de torque obtidos com os valores recomendados pelos fabricantes, a Unitek demonstrou maior fidedignidade no torque comparada às demais marcas. Conclui-se que as diferenças tanto de torque quanto de angulação quando comparados aos valores do autor e à prescrição dos fabricantes, se enquadram dentro de um grau de tolerância preconizada por um órgão regulador de peças ortodônticas alemãs.
50

AVALIAÇÃO DO COMPRIMENTO DA COROA CLÍNICA DOS DENTES ÂNTERO-INFERIORES EM PACIENTES TRATADOS COM APARELHO REGULADOR DE FUNÇÃO FRÄNKEL-2 / Orthodontic Appliances; Gingival Recession; Orthodontics.

Vasconcelos, Artur Cunha 14 April 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:17Z (GMT). No. of bitstreams: 1 ARTUR CUNHA VASCONCELOS.pdf: 1119532 bytes, checksum: ddde74bc354ed002746b09dda82ee5e1 (MD5) Previous issue date: 2011-04-14 / The aim of this study is to examine a possible change in the size of the clinical crown of the lower anterior teeth in 50 individuals with malocclusion, Angle Class II. The sample was divided into two groups: one group treated with 25 subjects (14 male and 11 female) with mean age at T1 (initial time of treatment) of 11 years, and T2 (time post-treatment) for 12 years and 7 months treated with the function regulator appliance Fränkel-2 for 18 months, and a control group of 25 subjects (12 male and 13 female) mean age at T1 for 10 years and 3 months and T2 in 12 years and 1 month. The plaster casts of 100 individuals were analyzed and compared between the beginning and end of treatment using a caliper, using as measure the distance from incisal to the concave portion of the gingival margin of the lower incisors and canines. Data were analyzed using the Student t test and paired t test. Among the six anterior teeth-less, all showed a significant increase in the treated group and only three teeth (33.42 and 43) increased significantly in the control group. In relation to the treatment group and control group at T2, a significant increase in the crown teeth 32, 33 and 43. There was a statistically significant increase in only two teeth (31 and 41) in both sexes. The results showed no statistical significance when compared to changing the size of the crown during the age. It is concluded that measures of clinical crowns of teeth differ between groups, being higher in the treated group. The increase in clinical crown of the teeth, is not related only by the presence of buccal inclination of the same, but may be considered as multifactorial. / O objetivo do estudo consistiu em verificar uma possível alteração no tamanho da coroa clínica dos dentes ântero-inferiores em 50 indivíduos portadores de má Oclusão de Angle Classe II. A amostra foi dividida em 2 grupos: um grupo tratado com 25 indivíduos (14 do sexo masculino e 11 do feminino) com idade média em T1 (tempo inicial do tratamento) de 11 anos (dp = 9 meses), e em T2 (tempo pós-tratamento) de 12 anos e 7 meses (dp = 7 meses), tratados com o aparelho regulador de função Fränkel-2, durante 18 meses; e, um grupo controle com 25 indivíduos (12 do sexo masculino e 13 do feminino) com idade média em T1 de 10 anos e 3 meses (dp = 11 meses) e em T2 de 12 anos e 1 mês (dp = 11 meses). Os 100 modelos em gesso dos indivíduos foram analisados e comparados em relação ao início e ao término do tratamento por meio de um paquímetro digital, utilizando-se como medida a distância da borda incisal até a porção mais côncava da margem gengival dos incisivos e caninos inferiores. Os dados foram analisados por meio do teste t de Student e teste t pareado. Dentre os seis dentes ântero-inferiores, todos apresentaram aumento significante no grupo tratado, e apenas três dentes (33,42 e 43) apresentaram aumento significante no grupo controle. Já em relação ao grupo tratado e o grupo controle em T2, houve um aumento significante da coroa nos dentes 32, 33 e 43. Houve um aumento estatisticamente significante em apenas dois dentes (31 e 41) em ambos os sexos. Os resultados não demonstraram relevância estatística quando comparados com a alteração do tamanho da coroa no decorrer da idade. Conclui-se que as medidas das coroas clínicas dos dentes diferiram entre os grupos, sendo maior no grupo tratado. O aumento da coroa clinica dos dentes, não esta relacionado somente pela presença de inclinação para vestibular dos mesmo, mas pode ser considerado como multifatorial.

Page generated in 0.0655 seconds