• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 96
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 5
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 99
  • 99
  • 48
  • 40
  • 40
  • 28
  • 24
  • 24
  • 23
  • 22
  • 22
  • 22
  • 20
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise de elementos finitos da distalização do primeiro molar superior com barra transpalatina ancorada em microparafusos ortodônticos

Dobranszki, Adriano 14 November 2014 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-01-29T14:43:44Z No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2015-02-10T18:12:36Z (GMT) No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / Made available in DSpace on 2015-02-10T18:12:36Z (GMT). No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / O objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, a distribuição de tensões em um primeiro molar superior, após aplicação de força de distalização em uma barra transpalatina (BTP) presa ao molar e ancorada em microparafusos ortodônticos (MPO) instalados em diferentes locais do palato e sugerir a indicação clínica para cada tipo de ativação. Tendo como fonte um banco de dados de tomografias volumétricas, medidas foram feitas e submetidas a análise estatística para criação de um modelo virtual válido de uma maxila humana de um indivíduo portador de relação maxilomandibular de Classe II esquelética típico. Este modelo foi utilizado como base para uma análise combinatória de 3 locais de instalação do MPO (2, 5 e 8 mm) e 3 pontos de ativação na BTP: próximo ao tubo lingual, na metade do comprimento do braço da barra e próximo ao ômega central, resultando em 9 modelos analisados com o programa ANSYS, cada um com aproximadamente 500.000 elementos tetraédricos. Imediatamente após aplicação de carga de 1,5 N na BTP, os valores do deslocamento inicial da trifurcação do molar e da rotação da coroa foram tabulados. Os resultados sugeriram que mudanças na posição de instalação do MPO e do ponto de ativação na BTP produziram diferentes efeitos na movimentação do primeiro molar superior, no sentido A-P, vertical e na rotação (angulação). Com os dados do modelo preliminar, concluiu-se que a maior concentração de tensões na BTP foi localizada na dobra próxima à entrada do tubo lingual, indicando o ponto de maior propensão à falha; no MPO, foi localizada na região do pescoço próximo à transição do perfil transmucoso para as espiras, região em contato com a borda externa do osso cortical palatino, indicando o ponto de maior propensão à falha; no osso cortical palatino, foi localizada na borda externa, mesial ao microparafuso, indicando o ponto em que provavelmente ocorreria maior demanda biológica inflamatória. No modelo definitivo, a ativação “2 mm apical”, próxima ao ômega central da BTP, foi a única que resultou em efeito extrusivo, com deslocamento mesial da coroa e distal das raízes e furca, ativação sugerida para distalização com aumento da dimensão vertical, por extrusão do molar. A ativação “2 mm cervical”, próxima ao tubo lingual do molar, resultou em um efeito leve de intrusão, distalização e acentuado giro distal da coroa, ativação sugerida para distalização quando o molar encontra-se mésioangulado. A ativação “5 mm média”, na metade do comprimento do braço da BTP, resultou em giro distal da coroa e leve movimento intrusivo, ativação sugerida quando o molar encontra-se com leve mesioangulação e ligeiramente extruído, ou quando se deseja distalizar fechando levemente a mordida anterior. A ativação “8 mm médio” produziu pouco efeito de distalização e pouco giro distal da coroa, sugerida quando se deseja pouca distalização com intrusão quase pura do molar, com angulação distal da coroa. A ativação “8 mm apical” produziu muito pouca distalização e acentuada intrusão e angulação distal da coroa, sugerida quando se deseja intruir o molar. ________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate by finite element analysis the stress distribution in a maxillary first molar after application of a distalization force on a transpalatal arch (TPA) attached to the molar and anchored on orthodontic microscrews (OMS) in different locations of the palate and suggest the clinical indication for each type of activation. Having as source a database of volumetric scans, measurements were made and subjected to statistical analysis to create a valid virtual model of a typical skeletal Class II maxillo-mandibular relationship individual. This virtual maxillary model was used as the basis for a combinatorial analysis of 3 OMS installation positions (2, 5 and 8 mm) and 3 TPA activation positions (near the lingual tube, in the half length of the bar arm and near the central omega, resulting in 9 models analyzed using ANSYS program, each with approximately 500.000 tetrahedral elements. Immediately after application of load of 1.5 N in the BTP, the values of the initial displacement of the trifurcation and of the rotation of the molar crown were tabulated. The results suggested that changes in the position of installation and OMS activation point of the TPA produced different effects on the movement of the upper first molar in the A-P and vertical directions and rotation (angle). With the data of the preliminary study it was concluded that the highest stress concentration on the TPA was located at the bend next to the entrance of the lingual tube, indicating the point of higher propensity to failure; on the OMS, it was located at the neck, near to the transition from the transmucosal profile for the thread, site in contact with the external edge of the palatal cortical bone, indicating the point of higher propensity to failure; on the palatal cortical bone, it was located at the external edge, mesial to the OMS, indicating the point where most likely would occur a higher inflammatory biological demand. In the definitive model, the "2 mm apical" activation, next to the central omega of the TPA, was the only activation that resulted in extrusive effect, with mesial displacement of the crown and distal displacement of the roots and of the furcation, suggested activation for distalization with increase of the vertical dimension, by molar extrusion. The "2 mm cervical" activation, next to the molar lingual tube, resulted in a light intrusive effect, distalization and marked crown distal rotation, activation suggested for distalization when the molar is angle to the mesial. The "5 mm activation", at the half of the TPA arm´s lenght, resulted in distal rotation of the crown and light intrusive movement, activation suggested when the molar is slightly angled to the mesial and slightly extruded, or when it is desired to distalize and close the anterior bite slightly. The "8 mm medium" activation produced little effect to the distalization and a slightly distal rotation of the crown, suggested when a slight distalization it is desirable, with almost pure intrusion of the molar with distal angulation of the crown. The "8 mm apical" activation produced very little effect on the distalization and a marked intrusion with distal angulation of the crown, suggested when it is desired to intrude the molar.
72

Avaliação in vitro da força de atrito entre braquetes e fios ortodonticos na distalização do canino superior pela Tecnica de Força Direcional Seqüencial de Tweed-Merrifield / Evaluation of frictional forces in vitro between brackets and orthodontic wires in upper cusp distalization according to the Tweed-Merrifield Sequential Directional Force Technique

Kuramae, Mayury 21 June 2006 (has links)
Orientador: Maria Beatriz Borges de Araujo Magnani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T01:50:59Z (GMT). No. of bitstreams: 1 Kuramae_Mayury_D.pdf: 15126221 bytes, checksum: 69a444f9af9fdfb714e7271ab940c8fb (MD5) Previous issue date: 2006 / Resumo: O objetivo desse estudo foi avaliar in vitro a força de atrito gerada na mecânica de distalização do canino superior pelo uso do gancho ¿J¿ na Técnica da Força Direcional Seqüencial de Tweed-Merrifield, de acordo com as variáveis: tipo e marcas dos braquetes; espessura e marcas dos fios; técnica de amarração e análise das superfícies dos fios e braquetes em microscopia eletrônica de varredura, microscopia de força atômica, além de rugosímetro. Foram utilizados 192 braquetes Edgewise de aço inoxidável de dois tipos e duas marcas comerciais e duas marcas de fios ortodônticos (Morelli, Sorocaba, São Paulo, Brasil e GAC, Central Islip, Nova Iorque, EUA) de aço inoxidável em quatro espessuras, amarrados por ligadura metálica e elastomérica em meio seco e à temperatura ambiente. Foi utilizada uma placa de acrílico retangular simulando um segmento de aparelho fixo composto por quatro braquetes duplos. Cada fio a ser testado teve suas extremidades dobradas justas aos braquetes terminais para que não deslizasse na canaleta e foi amarrado aos braquetes com ligadura de aço inoxidável. A placa de acrílico juntamente com o segmento do fio montado foi fixada no mordente da base da máquina de ensaio universal Instron 4411 (Instron Ltd., High Wycombe, Bucks, Reino Unido) de maneira a ficar posicionada em 45° em relação ao solo, o que foi realizado com o auxílio do esquadro, simulando a angulação do aparelho extrabucal gancho ¿J¿ com o plano oclusal, durante a mecânica de distalização do canino superior. O braquete foi puxado a velocidade de 0,5mm/minuto através do segmento do fio por uma distância de 5mm. Os testes foram repetidos três vezes, trocando-se a combinação braquete/fio a ser testada para cada três grupos. Os valores médios foram obtidos e a força de atrito foi calculada. Após o recorte das canaletas dos braquetes e limpeza dos fios e braquetes, esses foram analisados em microscopia eletrônica de varredura e de força atômica. Além disso, sobre a superfície dos fios foi efetuada a leitura da rugosidade de superfície em micrometros. Os dados foram submetidos à Análise de Variância e ao teste de Tukey (5%). Concluiu-se que: os braquetes duplos proporcionaram maior atrito do que os braquetes simples; os braquetes e fios da marca Morelli proporcionaram maior atrito do que os da GAC; quanto maior a espessura dos fios, maior foi o atrito; a técnica de amarração que gerou maior atrito foi com ligadura elástica quando comparada à ligadura de aço inoxidável; a rugosidade do fio diminuiu com o uso em alguns casos e os fios da marca GAC apresentaram qualitativamente lisura de superfície superior ao da marca Morelli / Abstract: This study aimed to evaluate in vitro frictional forces that result from upper cusp distalization due to using the J-Hook, according to the Tweed-Merrifield Sequential Directional Force technique; variables were: bracket type and manufacturer, wire diameter and manufacturer, ligation method and microscopic surface analysis of brackets and wires. One hundred and ninety-two stainless steel Edgewise brackets, of two different types and manufacturers were used, ligated to orthodontic wires of four diameters and two manufacturers (Morelli, Sorocaba, São Paulo, Brazil and GAC, Central Islip, New York, USA) by means of metallic and elastomeric ligatures, at extraoral environment and ambient temperature. A rectangular acrylic plate was manufactured, imitating a fixed appliance section of four double brackets. The ends of each wire were tightly bended to the terminal brackets, in order to eliminate sliding, and were fixed to the brackets by stainless steel ligatures. Each sample, comprising the acrylic plate, as well as the bracket and wire section, was fixed unto a Instron 4411 testing machine (Instron Ltd., High Wycombe, Bucks, United Kingdom), so that each of them was at a 45º inclination, relative to the horizontal plane, thus imitating the extraoral position of the J-hook, relative to the occlusal plane, during upper cusp distalization. The bracket was pulled for 5mm sliding at a speed of 0.5mm/minute. Tests were performed other three times, each for a different bracket/wire combination, over the three groups. The mean values were obtained and frictional forces were calculated. After cutting bracket slots and cleaning wires and brackets, these were analyzed by scanning electron and atomic force microscopy. Also, surface rugosity, in micrometers, was evaluated. Data underwent Variance analysis and Tukey test (5%). Final observations were: twin brackets provide greater frictional forces; brackets and wires manufactured by Morelli showed greater frictional forces than those by GAC; the larger the wire diameter, the greater the frictional forces; elastomeric ligatures resulted in greater friction than stainless steel ligatures; usage made the wires less roughness just in some cases, and GAC manufactured wires presented greater surface smoothness than those by Morelli / Doutorado / Ortodontia / Doutor em Radiologia Odontológica
73

A representação social de escolares adolescentes sobre a má oclusão e tratamento ortodôntico

Almeida, Anderson Barbosa de 14 September 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-10T17:56:14Z No. of bitstreams: 1 andersonbarbosadealmeida.pdf: 2734838 bytes, checksum: 6d8c0a9abe0557f813da617bb73fc5b4 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor corrigir data do documento: Data do documento: 14-Set-2018 on 2018-01-23T12:13:40Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:16:54Z No. of bitstreams: 1 andersonbarbosadealmeida.pdf: 2734838 bytes, checksum: 6d8c0a9abe0557f813da617bb73fc5b4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-23T13:20:39Z (GMT) No. of bitstreams: 1 andersonbarbosadealmeida.pdf: 2734838 bytes, checksum: 6d8c0a9abe0557f813da617bb73fc5b4 (MD5) / Made available in DSpace on 2018-01-23T13:20:39Z (GMT). No. of bitstreams: 1 andersonbarbosadealmeida.pdf: 2734838 bytes, checksum: 6d8c0a9abe0557f813da617bb73fc5b4 (MD5) Previous issue date: 2017-09-14 / O tratamento ortodôntico tem um impacto significativo na qualidade de vida e na auto-estima dos adolescentes, com implicações sociais, emocionais e comportamentais. Sua percepção é determinada por diversos aspectos subjetivos que não são totalmente compreendidos. A pesquisa qualitativa busca interpretar os significados psicológicos e socioculturais dos indivíduos acerca dos múltiplos fenômenos pertinentes ao campo dos problemas da saúde-doença. Assim, o objetivo desta pesquisa foi: identificar, através de uma revisão da literatura, artigos que utilizaram a metodologia qualitativa, identificando os principais aspectos do seu conteudo; e conhecer e analisar as representações sociais de escolares adolescentes sobre a má oclusão e o tratamento ortodôntico. Uma pesquisa qualitativa foi realizada através da análise de conteúdo de dados coletados de 142 adolescentes, de 12 a 15 anos de idade, 23 do gênero masculino e 48 do feminino, estudantes de 8 escolas, sendo 4 públicas e 4 particulares. Os métodos de pesquisa utilizados foram a TALP (Técnica de Associação de Palavras) seguido de oito grupos focais com 71 desses alunos. As palavras mais recorrentes na Técnica de Associação de Palavras demonstraram um impacto estético positivo do aparelho ortodôntico, tanto para a auto-avaliação dos adolescentes como para a avaliação de amigos. Vários temas foram identificados na análise qualitativa, sendo o benefício estético do tratamento ortodôntico e o impacto estético do aparelho, os pontos positivos mais relevantes. O aspecto negativo mais citado no estudo foi a dor associada ao tratamento, seguida pelos desconfortos e traumas causados pelo aparelho fixo. O tratamento ortodôntico tem um impacto estético positivo para adolescentes brasileiros com melhora da auto-imagem. Os aparelhos ortodônticos fixos demonstraram ter um impacto positivo imediato na aparência e são um fator importante nas relações comportamentais entre os adolescentes brasileiros, particularmente, devido à sua associação com o status social. A compreensão dos aspectos sociocomportamentais envolvidos no tratamento ortodôntico é fundamental para a relação clínica entre paciente e profissional. / Orthodontic treatment has a significant impact on the quality of life and self-esteem of adolescents, with emotional and behavioral implications. The objective of this research was to know the perception of Brazilian adolescents about the treatment and the orthodontic appliance. A qualitative research was carried out through content analysis of data collected from 142 adolescents, using the Word-Association Technique (WAT), followed by eight focal groups with 71 of these students. The most recurrent words on the WAT demonstrated a positive aesthetic impact of the orthodontic appliance, both for the self-assessment of the adolescents and the evaluation of friends. Several themes were identified in the qualitative analysis, being the aesthetic benefit of orthodontic treatment and the aesthetic impact of the appliance the most relevant positive points. The most cited negative aspect in the study was the pain associated with the treatment, followed by the discomforts and traumas caused by the fixed appliance. Orthodontic treatment has a positive aesthetic impact for Brazilian adolescents with an improvement of their self-image. Fixed orthodontic appliances have an immediate positive impact on appearance and are an important factor in behavioral relationships among Brazilian adolescents, particularly, due to their association with social status. The understanding of the socio-behavioral aspects involved in orthodontic treatment is of fundamental importance for the clinical relationship between patient and professional.
74

Compósitos cerâmicos alumina-zircônia para aplicação em bráquetes estéticos de ortodontia / Ceramic composites alumina-zirconia for application in orthodontic aesthetic brackets

Almeida, Fabiano Costa, 1969- 27 August 2018 (has links)
Orientador: Cecília Amélia de Carvalho Zaváglia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-27T01:43:48Z (GMT). No. of bitstreams: 1 Almeida_FabianoCosta_D.pdf: 3772112 bytes, checksum: cb918f5ac800f74bbb146bf9c3e50a84 (MD5) Previous issue date: 2015 / Resumo: Os bráquetes são suportes utilizados pelos ortodontistas para controlar o posicionamento dos dentes nos tratamentos ortodônticos. Por eles, mais precisamente por seus slots, passam os fios ortodônticos e ambos são responsáveis pela biomecânica dos movimentos. O bráquete pode ser confeccionado por diversos materiais, sendo o mais comum o metal pela praticidade, preço e resistência. Recentemente, com a maior demanda por aparelhos estéticos, devido ao aumento de adultos utilizando estes dispositivos, aumentou o uso de bráquetes estéticos, feitos geralmente de polímeros ou cerâmicas. As maiores dificuldades encontradas estão relacionadas a estética, resistência, capacidade de coloração por alimentos e maior atrito com o fio. O propósito deste estudo foi a obtenção de compósitos cerâmicos de alumina e zircônia (ZTA) a partir de pós finamente cominuídos em diferentes proporções 70/30, 80/20 e 90/10 provenientes de materiais cerâmicos de alumina e zircônia separadamente. Os compósitos cerâmicos (ZTA) foram submetidos a processos de análises do tamanho de partículas, moagens, prensagens, conformações de corpos de provas (c.p.), difração de raio X, ensaios de compressão diametral, análises das propriedades mecânicas, avaliações das microestruturas e análises de propagação de trincas. Os resultados demonstraram tamanhos de partículas de 0,3µ, os valores da compressão diamentral de 296,64 MPa, 262,60 MPa, 220,30 MPa, os valores de microdureza de 13,12 GPa, 13,42 GPa, 13,81 GPa, os valores de tenacidade à fratura de 8,91 MPa m½, 9,37 Mpa m½, 9,65 Mpa m½, os tamanhos de grãos em torno de 0,6µ e uma redução significativa nas propagações das trincas em relação à alumina. Estes compósitos cerâmicos de alumina e zirconia (ZTA) demonstraram resultados superiores em seus valores de tenacidade à fratura de aproximadamente 68% em relação a alumina, atualmente utlizados em bráquetes comerciais. Ocorreu uma redução do tamanho de grãos e modificações no comportamento de propagação das trincas resultando na diminuição da ocorrência de trincas. A conclusão, diante dos resultados apresentados nas análises, foi que os materiais compósitos cerâmicos de alumina e zircônia (ZTA), nos quesitos avaliados, foram adequados para serem aplicados em bráquetes estéticos de Ortodontia, porém novos trabalhos foram sugeridos para avaliação desses materiais em relação ao desgaste, a fricção e a coloração. Palavras-chave Aparelhos ortodonticos estéticos, bráquetes cerâmicos, compósitos cerâmicos, compósitos ZTA / Abstract: The brackets are used by orthodontists to control the tooth positions on orthodontic treatments. Inside the brackets, in the slots, are the orthodontic wire and both are responsible for the biomechanical movement. The brackets can be made of different materials and the most common is the metallic by practically, price and resitance. Recently, with the greatest demand of aesthetic devices, because a adult demand, increased use of aesthetic brackets made of polymers and ceramics. The greatest aesthetic difficulties are the resitence, staining for food and the wire friction. This work aims to contribute to the development of new aesthetic orthodontic brackets. Thereby was proposed in this study the obtainment of ceramic composites alumina and zirconia (ZTA) powder finely comminuted in different proportions 70/30, 80/20 and 90/10 from alumina and zirconia separately. These ceramic composites alumina and zirconia (ZTA) were submitted to particle analysis, milling process, pressing, specimens conformations, X ray diffraction, diametral compression, mechanical properties analysis, evaluation of microstructured and crack propagation analysis. The results showed particle size 0,3µ, the diametral compression values of 296,64 MPa, 262,60 MPa, 220,30 Mpa, the hardness values of 13,12 GPa, 13,42 GPa, 13,81 GPa, the fracture toughtness values of 8,91 MPa m½, 9,37 Mpa m½, 9,65 Mpa m½, the grain size of 0,6µ and a significant reduction in crack propagation compared to alumina. These ceramic composites alumina and zirconia (ZTA) demonstrated superior results in their fracture toughness values of approximately 68% compared to alumina, currently used in commercial brackets. There was a reduction in grain size and changes in the behavior of propagation of cracks resulting in a decrease of occurance of cracks. The conclusion on the results presented was that ceramic composites alumina and zirconia (ZTA), on the variables evaluated, were suitable for application in Orthodontic aesthetic brackets however new studies have been suggested for the evaluation of these materials in relation to wear, friction and staining. Key Words Aesthetic orthodontic devices, ceramic brackets, ceramic composites, ZTA composites / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
75

Camuflagem ortodôntica da má oclusão de classe III - resultados e estabilidade / Class III malocclusion camouflage treatment: results and stability

Karine Vaz Laskos Sakoda 15 May 2018 (has links)
O objetivo desse trabalho foi avaliar os efeitos da camuflagem ortodôntica da má oclusão de Classe III em adultos por meio de uma revisão sistemática da literatura, bem como comparar a estabilidade do tratamento da má oclusão de Classe III na dentadura permanente entre as prescrições Biofuncional de Classe III e Roth. A revisão sistemática incluiu estudos que avaliaram indivíduos adultos com má oclusão de Classe III submetidos à camuflagem ortodôntica. A partir da busca eletrônica realizada em diferentes bases de dados, sem limitações quanto ao ano ou idioma das publicações, 9 estudos retrospectivos foram selecionados. Desses, 8 apresentaram risco de viés elevado, de acordo com uma versão modificada da checklist de Downs & Black. Diferentes métodos para correção da má oclusão de Classe III foram descritos e incluíram extrações de pré-molares superiores e inferiores, extrações de incisivos inferiores, utilização de elásticos intermaxilares de Classe III e distalização do arco inferior. As extrações dentárias realizadas no arco inferior resultaram em inclinação lingual e retrusão dos incisivos inferiores e inclinação vestibular e protrusão dos incisivos superiores. A utilização de elásticos intermaxilares de Classe III promoveu vestibularização dos incisivos superiores, extrusão dos molares superiores, inclinação distal dos molares inferiores, extrusão dos incisivos inferiores e rotação horária da mandíbula. A distalização do arco inferior resultou em inclinação distal dos molares inferiores, retração e lingualização dos incisivos inferiores e rotação anti-horária da mandíbula. A estabilidade da camuflagem ortodôntica da má oclusão de Classe III na dentadura permanente foi comparada entre as prescrições Biofuncional de Classe III e Roth. A amostra foi dividida em dois grupos, conforme a prescrição utilizada. O grupo Biofuncional foi composto por 11 indivíduos tratados com a prescrição Biofuncional de Classe III. O grupo Roth incluiu 18 indivíduos tratados com a prescrição Roth. Telerradiografias em norma lateral foram obtidas previamente ao tratamento ortodôntico (T1), após o tratamento (T2) e após um período de acompanhamento (5,23 anos, em média) (T3). Comparações cefalométricas entre os grupos foram realizadas em T1, T2, T3 e nos intervalos T2-T1 e T3-T2. Comparações intragrupos foram realizadas nas três fases avaliadas (P<0,05). Os efeitos do tratamento foram diferentes entre os grupos, com inclinação vestibular e protrusão dos incisivos superiores e inclinação lingual dos incisivos inferiores no grupo Roth. O resultado obtido se manteve estável em ambos os grupos, porém, a variável 1.NA apresentou maior alteração do grupo Roth no período pós-tratamento. Conclui-se que as alterações promovidas pela camuflagem ortodôntica da má oclusão de Classe III na dentadura permanente são influenciadas pelo método empregado na correção da má oclusão e são predominantemente dentoalveolares. Diferentes modalidades de tratamento apresentaram resultados estáveis após um período de acompanhamento e incluem camuflagem ortodôntica da má oclusão de Classe III com extração de um incisivo inferior, gancho J de tração alta, utilização da técnica do arco multiloop (MEAW) associada ou não a mini-implantes, além do tratamento com as prescrições Biofuncional de Classe III e Roth associadas a elásticos intermaxilares de Classe III. / The aim of this study was to the effects of the camouflage treatment of Class III malocclusion in adults through a systematic review of the literature and to compare the stability of Class III malocclusion camouflage treatment in the permanent dentition between Biofunctional and Roth prescriptions. The systematic review included studies that evaluated nongrowing individuals with class III malocclusion, undergoing orthodontic camouflage treatment. From the electronic search in different databases, with no limitations regarding publication year or language, 9 retrospective studies were selected. Of these, 8 presented high risk of bias, according to a modified version of the Downs & Black checklist. Different methods for Class III malocclusion correction were described and included upper and lower premolars extractions, lower incisor extraction, Class III intermaxillary elastics and distalization of the mandibular dentition. Extractions in the lower arch resulted in lingual tipping and retrusion of lower incisors, and buccal tipping and protrusion of upper incisors. The use of Class III intermaxillary elastics promoted proclination of upper incisors, extrusion of upper molars, distal tipping of lower molars, extrusion of lower incisors, and clockwise rotation of the mandible. Distalization of the mandibular dentition resulted in distal tipping of lower molars, retroinclination and retraction of lower incisors, and counterclockwise rotation of the mandible. It can be concluded that treatment changes are influenced by the method employed to camouflage the Class III malocclusion in adults and are mainly dentoalveolar. Stability of Class III malocclusion camouflage treatment in the permanent dentition was compared between Biofunctional and Roth prescriptions. The sample was divided in two groups, according to the prescription used. Biofunctional group consisted of 11 subjects treated with the Biofunctional prescription (average age of 16.57 years). Roth group included 18 subjects treated with the Roth prescription (average age of 16.25 years). Cephalometric radiographs were taken before orthodontic treatment (T1), after treatment (T2) and after a follow-up period (5.23 ±3.45 years) (T3). Cephalometric comparisons between groups were performed at T1, T2, T3 and at the T2-T1 and T3-T2 intervals. Intragroup comparisons were performed for the three evaluated periods (P<0.05). Treatment effects were different between the groups, with proclination and protrusion of maxillary incisors, and retroinclination of mandibular incisors in the Roth group. The obtained results were stable in both groups; however, variable 1.NA presented higher change in the Roth group in the follow-up period. It can be concluded that treatment changes are influenced by the method employed to camouflage the Class III malocclusion in the permanent dentition and are mainly dentoalveolar. Different treatment modalities presented stable results after a follow-up period and included orthodontic camouflage of Class III malocclusion with extraction of a lower incisor, high pull J-hook headgear, multiloop edgewise archwire technique (MEAW) associated or not with mini- implants and, also, treatment with Biofunctional and Roth prescriptions associated with Class III intermaxillary elastics.
76

Estudo comparativo dos efeitos dentoesqueléticos do tratamento da má oclusão de Classe II com o distalizador Jones jig e com extrações dos primeiros pré-molares superiores / Comparative study of dentoskeletal effects of Class II malocclusion tratament with Jones jig appliance and with extraction of first maxillary premolars

Daniela Cubas Pupulim 19 February 2013 (has links)
O objetivo deste estudo foi comparar as alterações cefalométricas de pacientes com má oclusão de Classe II divisão 1 tratados com o distalizador Jones jig e com extrações dos primeiros pré-molares superiores. A amostra foi constituída por 88 telerradiografias em norma lateral de 44 pacientes, os quais foram divididos em 2 grupos. O grupo Jones jig consistiu de 21 pacientes tratados com o aparelho Jones jig, com idade média inicial de 12,88 ± 1,23 anos e final de 17,18 ± 1,37 anos, e tempo médio de tratamento de 4,29 anos. O grupo extrações dos primeiros prémolares superiores foi composto por 23 pacientes, tratados com extrações dos primeiros pré-molares superiores, com idade média inicial de 13,59 ± 1,91 anos e final de 16,39 ± 1,97 anos, e tempo médio de tratamento de 2,8 anos. As comparações intergrupos foram realizadas por meio do teste t independente e Mann-Whitney. A correção da Classe II no grupo extrações dos primeiros prémolares superiores apresentou maiores alterações esqueléticas com redução do SNA, ANB e NAP. Houve um aumento da altura facial ântero-inferior, suave protrusão e extrusão dos incisivos superiores no grupo Jones jig. Os primeiros molares superiores mostraram significante inclinação mesial e mesialização em ambos os grupos, e o trespasse horizontal foi mais eficientemente corrigido no grupo extrações dos primeiros pré-molares superiores. Por outro lado, os primeiros molares inferiores apresentaram uma extrusão significantemente maior no grupo Jones jig. / The aim of this study was to compare the cephalometric changes of Class II division 1 malocclusion patients treated with Jones jig appliance and with 2 maxillary first premolar extractions. The sample consisted of 88 lateral cephalograms of 44 patients, divided into 2 groups. Jones jig group consisted of 21 patients treated with the Jones jig appliance, with mean initial age 12,88 ± 1,23 years and final mean age 17,18 ± 1,37 years, and a mean treatment time of 4,29 years. Maxillary first premolar extractions group comprised 23 patients treated with maxillary first premolar extractions, with initial mean age 13,59 ± 1,91 years and final mean age 16,39 ± 1,97 years, and a mean treatment time of 2,8 years. Intergroup treatment changes were compared with independent t and Mann-Whitney tests. Class II correction in maxillary first premolar extractions group had greater skeletal effect with reduction of SNA, ANB and NAP. There was an increase of anterior face height, mild protrusion and extrusion of the maxillary incisors in Jones jig group. The maxillary first molars showed greater mesial tipping and mesialization in both of groups and overjet was more efficiently corrected in maxillary first premolar extractions group. On the order hand, the mandibular first molars showed extrusion in the Jones jig group.
77

"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT technique

Moresca, Ricardo Cesar 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I – 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II – 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III – 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV – 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I – 14 subjects in which active lacebacks were used in the upper arch; group II – 9 subjects in which passive lacebacks were used in the upper arch; group III – 19 subjects in which active lacebacks were used in the lower arch; group IV – 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.
78

Estabilidade da correção da Classe II, 1ª divisão com o aparelho Bionator de Balters associado ao aparelho fixo / Stability of the correction of the Class II, division 1 malocclusion with the Balters Bionator associated to fixed appliances

Francisconi, Manoela Fávaro 25 February 2011 (has links)
Recursos ortopédicos e ortodônticos, utilizados de forma associada, têm se mostrado uma opção terapêutica eficiente no tratamento da má oclusão de Classe II, 1ª divisão desde que o paciente ainda apresente um potencial de crescimento favorável. Entretanto, as alterações nas relações esqueléticas, dentárias e tegumentares só podem ser consideradas satisfatórias caso permaneçam estáveis. Assim, este trabalho teve o propósito de avaliar cefalometricamente e por meio de modelos de estudo, a estabilidade das alterações decorrentes do tratamento com o aparelho Bionator de Balters, seguido do aparelho fixo, após um período médio de 10 anos. O grupo experimental compreendeu 23 pacientes que foram avaliados em três fases: inicial (T1), final (T2) e longo tempo pós-tratamento (T3). Foram avaliadas as telerradiografias em norma lateral (inicial, final e longo tempo pós-tratamento), totalizando 69 telerradiografias, e foram mensurados 69 modelos de estudo, avaliados nas fases previamente descritas, através do índice PAR. Também calculou-se a diferença entre o PAR inicial e o PAR final, a % de melhora obtida com esta terapia e a % de recidiva, ambas através do índice PAR. As variáveis analisadas foram comparadas por meio da análise de variância (ANOVA) para medidas repetidas e o teste de comparações múltiplas de Tukey. A terapia estudada não propiciou alterações no desenvolvimento maxilar. Observou-se um aumento na protrusão mandibular, bem como um maior incremento no comprimento efetivo da mandíbula. A relação maxilomandibular foi corrigida, notou-se uma melhora na convexidade facial, com a diminuição do ângulo ANB. Alterações significantes no padrão de crescimento craniofacial não foram observadas. Verificou-se, através da variável FMA e no período de longo tempo pós-tratamento, uma rotação do plano mandibular no sentido anti-horário. O posicionamento vertical da maxila (SN.PP) também não se alterou. Os incisivos superiores sofreram lingualização e retrusão. Os primeiros molares superiores mostraram um pequeno aumento no sentido vertical semelhante ao fisiológico, que ocorre pelo processo de flutuação normal. Em contrapartida, os incisivos inferiores sofreram vestibularização e protrusão. Os primeiros molares inferiores, por sua vez, apresentaram um deslocamento no sentido vertical (extrusão) e horizontal (mesialização), contribuindo, assim, para a correção da má-oclusão de Cl II. O tratamento também foi efetivo em corrigir os respasses, horizontal e vertical, bem como a relação molar. O ângulo nasolabial não foi afetado pelo tratamento, mostrando que os aparelhos ortopédicos não afetam substancialmente esta variável. Além disso, é de suma importância, ressaltarmos que, as alterações obtidas, com o tratamento realizado, permaneceram estáveis no período de longo tempo pós-tratamento; demostrando, dessa maneira, a efetividade da terapia selecionada. Finalmente, na análise dos modelos de estudo, os valores do índice PAR sofreram uma redução estatisticamente significante e permaneceram estáveis no período de longo tempo pós-tratamento. A porcentagem de melhora obtida com esta terapia foi de 81,78% e a de recidiva foi de 4,90%. Esses dados refletem que o Bionator de Balters, associado ao aparelho fixo, é uma efetiva alternativa para o tratamento da má-oclusão de Cl II, 1ª divisão. / Orthopedic and orthodontic approaches, used in an associated way, are being considered an efficient therapeutic option for the treatment of the Class II, division 1 malocclusion when the patient still presents a favorable growth potential. However, changes in skeletal, dental and soft tissue relationships only can be considered satisfactory if they remain stable. This study aimed to evaluate, cephalometrically and in dental casts, the stability of the changes resulting from the treatment with the Balters Bionator followed by the fixed appliances, after a mean period of 10 years. The experimental group comprised 23 patients who were evaluated in three stages: initial (T1), final (T2) and long-term posttreatment (T3). A total of 69 lateral cephalograms (initial, final and long-term posttreatment) were evaluated and also 69 dental casts were measured, in the stages previously described, using the PAR index. Furthermore, the difference between initial PAR and final PAR, the percentage of obtained improvement with the therapy and the percentage of relapse were calculated, using the PAR index. Evaluated variables were compared by the analysis of variance (ANOVA) for repeated measures and Tukey test. The studied therapy did not provide changes in maxillary development. An increase in mandibular protrusion, as well as a greater increase in effective length of the mandible, was observed. The maxillomandibular relationship was corrected, and an improvement in the facial convexity was observed, with a decrease of the ANB angle. Significant changes in craniofacial growth were not observed. The analysis of the FMA variable and of the long-term posttreatment revealed a rotation of the mandibular plane in a counterclockwise direction. The vertical positioning of the maxilla (SN.PP) also did not change. The maxillary incisors presented a palatal inclination and retrusion. The maxillary first molars showed a small increase in the vertical direction, similar to the physiological one, which occurred by the normal fluctuation process. In contrast, the mandibular incisors presented a buccal inclination and protrusion. The mandibular first molars showed a displacement in the vertical (extrusion) and horizontal (mesial) direction, which contributed to the correction of the Class II malocclusion. The treatment was also effective in correcting the overbite and overjet, and the molar relationship. The nasolabial angle was not affected by treatment, showing that orthopedic appliances did not significantly affect this variable. Finally, the analysis of the dental casts showed that the values of the PAR index presented a statistically significant reduction and remained stable at the long-term posttreatment. The percentage of improvement obtained with this therapy was of 81.78% and the percentage of relapse was of 4.90%. These data denote that Balters Bionator associated to the fixed appliances is an effective alternative for the treatment of the Class II, division 1 malocclusion.
79

Avaliação cefalométrica comparativa dos efeitos do aparelho de protração mandibular em adultos e adolescentes / Mandibular protraction appliance (MPA) effects in adolescents and adults: a cephalometric comparison

Furquim, Bruno D'Aurea 09 February 2009 (has links)
Este estudo retrospectivo teve como objetivo comparar os efeitos esqueléticos, dentários e tegumentares do tratamento com Aparelho de Protração Mandibular (APM) em conjunto com o aparelho fixo em pacientes adolescentes e adultos com má oclusão de Classe II. A amostra foi composta por telerradiografias pré e póstratamento de 23 adolescentes (idade inicial média de 11,75 anos) e de 16 adultos (idade inicial média de 22,41 anos). Testes t (P < 0,05) foram empregados para comparação dos grupos. Os adultos apresentaram menor quantidade de alterações esqueléticas. Com relação às alterações dentárias, os adultos apresentaram menor inclinação lingual dos incisivos superiores; menor extrusão dos incisivos inferiores; menor extrusão dos molares superiores e inferiores; menor mesialização dos molares inferiores; e menor retrusão do lábio superior em comparação aos adolescentes. / The aim of this retrospective study was to compare the skeletal, dental, and soft tissue effects of the Mandibular Protraction Appliance (MPA) treatment in adolescent and adult Class II malocclusion patients. The sample comprised pretreatment and posttreatment cephalograms of 23 adolescents (mean pretreatment age 11.75 years) and 16 adults (mean pretreatment age 22.41 years). The groups were compared with t tests, at P < 0.05. The amount of skeletal changes was smaller in the adult group. Adults showed smaller maxillary incisors lingual tipping, mandibular incisor and molar and maxillary molar extrusion and mandibular molar mesialization. Additionally, adults also showed greater upper lip retrusion as compared to adolescents.
80

Avaliação da contaminação microbiana de aparelhos ortodônticos removíveis, com e sem utilização de agente antimicrobiano, pela técnica Checkerboard DNA-DNA Hybridization - Estudo Clínico Randomizado / Detection of microbial contamination of removable orthodontic appliances with or without use of antimicrobial agent, by the Checkerboard DNA-DNA Hybridization, A randomized clinical study

Perdiza, Marcela 14 October 2009 (has links)
O objetivo do presente estudo clínico randomizado foi avaliar in vivo, por meio da técnica de biologia molecular Checkerboard DNA-DNA Hybridization: 1) A contaminação de aparelhos ortodônticos removíveis por 40 espécies bacterianas; 2) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sobre microrganismos cariogênicos; e 3) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sobre microrganismos periodontopatogênicos dos complexos laranja e vermelho. Participaram do estudo 20 pacientes de 7 a 11 anos de idade, em tratamento com aparelhos ortodônticos removíveis. O estudo constou de 2 etapas, com intervalo de 15 dias entre cada uma, de forma que todos os pacientes participassem tanto do grupo controle, quanto do grupo experimental. Em cada etapa os pacientes receberam um novo aparelho (totalizando 2 aparelhos por indivíduo) e um frasco plástico contendo a solução a ser borrifada sobre os aparelhos, porém os indivíduos não sabiam qual solução estavam utilizando. Os aparelhos foram utilizados em período integral, inclusive à noite, sendo removidos apenas durante as refeições Os pacientes do Grupo Controle foram orientados a usar solução placebo, sob a forma de spray, 2 vezes por semana, por 7 dias. Os pacientes do Grupo Experimental foram orientados a usar solução à base de gluconato de clorexidina a 0,12% (Periogard®) sob a forma de spray, da mesma forma que o grupo Controle. Decorridos 7 dias, os aparelhos de cada etapa foram removidos e processados para detecção de 40 espécies bacterianas, incluindo microrganismos cariogênicos e periodontopatogênicos, pela técnica Checkerboard DNA-DNA Hybridization. Os resultados obtidos foram analisados por meio do teste não-paramétrico de Wilcoxon, utilizando o software SAS (Statistical Analysis System). O nível de significância adotado foi de 5%. De acordo com os resultados obtidos observou-se que os aparelhos ortodônticos removíveis dos pacientes do grupo controle estavam densamente contaminados pelos microrganismos avaliados. A maioria das sondas utilizadas estava presente nas amostras desse grupo, sendo que S. sanguinis, S. oralis, S. gordonii e E. corrodens ocorreram em 100% dos aparelhos. Dentre os microrganismos cariogênicos, S. mutans e S. sobrinus foram encontrados em maiores quantidades que L. acidophilus e L. casei. As bactérias periodontopatogênicas pertencentes ao complexo vermelho foram evidenciadas em maiores quantidades que as pertencentes ao complexo laranja. Dentre os demais complexos não associados com patologias específicas, o complexo roxo apresentou-se em maiores quantidades, estando presente em 34% das amostras. Após o uso de spray com gluconato de clorexidina a 0,12%, observou-se uma diminuição significante dos microrganismos cariogênicos (S.mutans e S. sobrinus e L. acidophilus) nos aparelhos ortodônticos removíveis (p<0,05). Observou-se também uma diminuição significante de todos os microrganismos periodontopatogênicos dos complexos laranja e vermelho (p<0,05), em relação ao grupo controle, com exceção apenas do T. socranskii. Conclui-se que os aparelhos ortodônticos removíveis encontraram-se multicolonizados por diversas espécies bacterianas e que a clorexidina, utilizada duas vezes por semana sob a forma de spray, foi eficaz na redução dos níveis de microrganismos cariogênicos e periodontopatogênicos dos complexos laranja e vermelho, nesses aparelhos. / Using the Checkerboard DNA-DNA Hybridization biomolecular technique, this randomized clinical study evaluated: 1) the contamination of removable orthodontic appliances by 40 bacterial species; 2) the efficacy of 0.12% chlorhexidine gluconate (Periogard®) spray against cariogenic microorganisms;and 3) the efficacy of 0.12% chlorhexidine gluconate spray against periodontopathogenic microorganisms of the orange and red complexes. Twenty 7-11-year-old patients under treatment with removable orthodontic appliances were enrolled. The study had two phases, with a 15-day interval between them, in such a way that patients participated both in the control and in the experimental group. In each phase, the patients received a new appliance (total of 2 appliances per patient) and a bottle containing a solution to be sprayed onto the appliances, but they were blinded to whether it was a placebo solution or an antimicrobial agent. The patients were instructed to wear the appliances full-time, even at night, removing only at meals. The patients in the control and experimental groups were instructed to spray the placebo or the 0.12% chlorhexidine gluconate-based solution (Periogard®), respectively, onto the appliances twice a week during 7 days. After this period, the appliances of each phase were collected and processed for detection of 40 bacterial species, including cariogenic and periodontopathogenic microorganisms by the Checkerboard DNA-DNA Hybridization technique. Data were analyzed statistically by the non-parametric Wilcoxon test using the SAS software (Statistical Analysis System) at 5% significance level. The results showed that the removable orthodontic appliances of the patients in the control group were heavily contaminated by the target microorganisms. Most bacterial probes used were present in the control samples, S. sanguinis, S. oralis, S. gordonii and E. corrodens being detected in 100% of the appliances. Among the cariogenic microorganisms, S. mutans and S. sobrinus were found in larger numbers than L. acidophilus and L. casei. The number of red complex periodontopathogenic bacteria was larger than that of orange complex periodontopathogenic bacteria. Among the other bacterial complexes not associated with specific pathologies, purple complex bactéria were present in larger numbers, being detected in 34% of the samples. After use of the 0.12% chlorhexidine gluconate spray, the number of the cariogenic microorganisms (S.mutans, S. sobrinus and L. acidophilus) decreased significantly in the removable orthodontic appliances (p<0,05). There was also a significant decrease in the numbers of all periodontopathogenic microorganisms of the orange and red complexes (p<0,05), compared to the control group, except for T. socranskii. In conclusion, the removable orthodontic appliances were multicolonized by several bacterial species, and the use of chlorhexidine spray twice a week was effective in reducing the levels of cariogenic and periodontopathogenic microorganisms of the orange and red complexes.

Page generated in 0.104 seconds