• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 57
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 65
  • 41
  • 22
  • 16
  • 11
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Influ?ncia da altera??o do plano oclusal: magnitude do movimento e tipo de osteoss?ntese na resist?ncia mec?nica da fixa??o na osteotomia sagital do ramo mandibular: estudo in vitro

Santos, Victor Diniz Borborema dos 19 July 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-10-05T00:11:27Z No. of bitstreams: 1 VictorDinizBorboremaDosSantos_DISSERT.pdf: 2006909 bytes, checksum: bac53377cdf34bb2c1b4d10fc273d846 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-10-16T21:50:04Z (GMT) No. of bitstreams: 1 VictorDinizBorboremaDosSantos_DISSERT.pdf: 2006909 bytes, checksum: bac53377cdf34bb2c1b4d10fc273d846 (MD5) / Made available in DSpace on 2017-10-16T21:50:04Z (GMT). No. of bitstreams: 1 VictorDinizBorboremaDosSantos_DISSERT.pdf: 2006909 bytes, checksum: bac53377cdf34bb2c1b4d10fc273d846 (MD5) Previous issue date: 2017-07-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / O objetivo deste trabalho foi avaliar, atrav?s de um ensaio biomec?nico a resist?ncia da fixa??o na osteotomia sagital do ramo mandibular (OSRM) em dois tipos de avan?os (6 e 12 mm), associados ou n?o a rota??o do plano oclusal, utilizando placas e parafusos do sistema 2.0 mm. Foram utilizadas hemimand?bulas de poliuretano, com OSRM padronizadas, divididos em 7 grupos: Avan?o linear de 6 mm / 1 placa e 4 parafusos (G1); avan?o linear de 12 mm/1 placa e 4 parafusos (G2); avan?o linear de 12 mm /2 placas e 8 parafusos (G3); avan?o de 12 mm, associado a rota??o hor?ria do plano oclusal / 1 placa e 4 parafusos (G4); avan?o de 12 mm, associado a rota??o hor?rio do plano oclusal/2 placas e 8 parafusos (G5); avan?o de 12 mm, associado ao giro anti-hor?rio do plano oclusal / 1 placa e 4 parafusos (G6); - avan?o de 12 mm, associado ao giro anti-hor?rio do plano oclusal/2 placas e 8 parafusos (G7). As hemimand?bulas foram submetidas a uma carga compressiva vertical na regi?o de primeiro molar e a for?a aplicada, em Newtons, foi registrada nos deslocamentos de 1mm, 5 mm e 10 mm, bem como tamb?m a for?a m?xima. Utilizando um intervalo de confian?a de 95%, as medianas de for?a foram obtidas e os grupos foram comparados entre si. Os testes estat?sticos utilizados foram o Kruskal-Wallis* para a an?lise de todos os grupos e o de Mann-Whitney** para o comparativo de dois grupos separadamente. Os resultados mostraram que, segundo o teste de Kruskall-Wallis houve diferen?as entre os grupos. Ficou demonstrado que o aumento da magnitude do avan?o mandibular diminuiu a resist?ncia da osteoss?ntese na OSRM quando se utilizou um ?nico dispositivo de fixa??o. A inser??o de uma placa adicional em grandes avan?os (G3, G5 e G7), aumentou significativamente a resist?ncia do m?todo de osteoss?ntese de uma maneira geral, quando comparada aos demais grupos. Em grandes avan?os com modifica??o do plano oclusal fixados com uma ?nica placa (G4 e G6), houve um aumento significativo da resist?ncia da fixa??o apenas no movimento de rota??o hor?ria. A rota??o anti-hor?ria do plano oclusal foi significativamente mais resistente que a hor?ria, quando se utilizou 2 placas na estabiliza??o da OSRM. / The aim of this study was to evaluate the resistance of fixation in the sagittal osteotomy of the mandibular ramus (OSRM) when performing great advances (12 mm), as well as the influence of the movement associated with the anticlockwise/clockwise rotation of the occlusal plane , Using plates and screws of the 2.0 mm system. Two types of advances were used (6 and 12 mm) using polyurethane hemimandibulars, with standardized OSRM, divided into 7 groups: G1 - linear advance of 6 mm / 1 plate and 4 screws; G2 - linear advance of 12 mm / 1 plate and 4 screws; G3 - linear advance of 12 mm / 2 plates and 8 screws; G4 - 12 mm advance, associated with clockwise rotation of the occlusal plane (15 ?) / 1 plate and 4 screws; G5 - 12 mm advance, associated with clockwise rotation of the occlusal plane (15 ?) / 2 plates and 8 screws; G6 - 12 mm advance, associated with anticlockwise rotation of the occlusal plane (15 ?) / 1 plate and 4 screws; G7 - 12 mm advance, associated with the counterclockwise rotation of the plane (15 ?) / 2 plates and 8 screws. The hemimandibules were submitted to a vertical compressive load in the first molar region and the applied force in Newtons was recorded in the displacements of 1mm, 5mm and 10mm, as well as the maximum force applied between 1 and 10mm. Using a 95% confidence interval, the means of strength were obtained and the groups were compared to each other. The statistical tests used were Kruskal-Wallis for the analysis of all groups and the Mann-Whitney test for comparison of two groups separately. The results showed that, according to the Kruskall-Wallis test, there were differences between groups. When only 1 plate was used for the fixation of the hemimandibula, at the 12 mm advance, the clockwise rotation was more resistant than in the linear movement, at the displacements of 1, 5 and 10 mm (p <0.05 **), Not resulting in statistical difference only in the maximum displacement (p = 0.112 **). In a large advance (12mm) there was a significant loss of resistance in the FIR, being necessary to compensate this situation with use of more fixation and the clockwise/counterclockwise rotation in these cases also added resistance in the OSRM, only in cases where a single plate is used. The counter-clockwise turn proved to be less sturdy than the clockwise rotation when fixed with one plate and more resistant when fixed with 2 plates. Both situations presented statistical significance with p <0.05. In view of these findings, it was concluded that regardless of movement, the fixation with 2 plates considerably increases the resistance to applied force.
62

Estudo comparativo entre duas técnicas para montagem do modelo de gesso de arcadas superiores em articulador semi-ajustável / A comparative study between two techniques to mount the maxillary cast in semi-adjustable articulator

Rogério Ribas da Costa 20 November 2001 (has links)
Este estudo avaliou a habilidade de duas técnicas, uma convencional e uma de transferência direta do molde, para a montagem do modelo de gesso maxilar no articulador. Um único paciente do sexo feminino, 39 anos, portador de arcada superior de Classe I de Kennedy (desdentado posterior bilateral) foi usado para esta investigação. Foram obtidos 20 modelos de gesso em cada técnica, totalizando 40 montagens nos articuladores. Com o modelo maxilar montado, cada articulador foi fotografado do mesmo lado direito da radiografia em norma lateral da paciente, obtida com o arco facial montado em sua face. As medidas analisadas nos traçados realizados sobre as fotografias e na radiografia, foram obtidas calculando-se o ângulo entre a interseção do plano oclusal da maxila e o plano de referência horizontal (plano de Frankfurt), representado pelo arco facial na radiografia da paciente, comparando-o com o ângulo entre o plano oclusal do modelo de gesso e o ramo superior do articulador em ambas as técnicas, por meio do software UTHSCSA Image Tool. O dados foram submetidos à análise estatística. Os resultados deste estudo demonstraram uma capacidade maior de reprodução daquele ângulo quando uma técnica de transferência direta do molde é usada. Da mesma maneira, foi verificado uma distorção significante na reprodutibilidade dos modelos montados pela técnica convencional. / This study assessed the ability of two techniques to mount the maxillary cast in the articulator, a conventional technique and one of direct transfer of the maxillary arch impression from the patient\'s mouth to the articulator. A single female subject, 39 years old, with a partially edentulous arch, Kennedy´s Class I, was used in this investigation. It was obtained 20 casts in each technique, totaling 40 cast mountings in the articulators. With the maxillary cast mounted, each articulator was photographed in the same right side of the lateral skull cephalometric radiograph of the patient with the face-bow mounted in her face. The measures obtained by the photographic and cephalometric tracings were evaluated by calculating the angle made by the intersection of the maxillary occlusal plane with craniofacial horizontal reference plane (Frankfort´s plane) on the patient´s cephalogram and comparing it with the angle between the occlusal plane of the cast with the upper member of the articulators in both techniques using the UTHSCSA Image Tool computerized program. The measuring data was submitted to the statistical analysis. The results of this study demonstrated a better capacity of reproduction of that angle when a direct transfer technique is used. In the same way, it was found a significant low level of reproducibility in mounting the maxillary cast when a conventional technique is used.
63

Avaliação in vitro da transmissão de carga oclusal em próteses sobre implantes em função da inclinação de implantes através de análise fotoelástica / In vitro evaluation of occlusal load transmission in prosthetic implant according to the inclination of implants by photoelastic analysis

Edson Koji Takeshita 01 September 2011 (has links)
A técnica All-on-Four foi idealizada visando diminuir a extensão do cantilever nas reabilitações de pacientes edêntulos com próteses implantossuportadas. Contudo, ainda persistem questionamentos relacionados ao comportamento biomecânico dos implantes e da própria técnica All-on-Four, posto que, questões como a perda óssea peri-implantar e falência de componentes da prótese ainda não estão claramente elucidadas. O objetivo da pesquisa foi avaliar a dissipação de tensões em próteses implantossuportadas dos tipos Branemark e All-on-Four, sob carga oclusal estática, e o papel do lado de balanceio e do comportamento do complexo implantes/próteses. Foram confeccionadas seis réplicas de mandíbula humana em resina fotoelástica, divididas em dois grupos:um com quatro implantes dispostos axialmente e paralelas entre si no espaço interforaminal (mandíbulas Branemark), e outro com quatro implantes inseridos de acordo com a técnica All-on-Four. Confeccionou-se uma prótese total implantossuportada, de maneira que se adaptasse em todas as seis mandíbulas. O experimento foi conduzido com o auxílio de um dispositivo giratório de carga, que permitiu a visualização das mandíbulas por todos os ângulos, sem alteração da carga aplicada. Após a fixação padronizada do corpo de prova no dispositivo, a prótese foi parafusada sobre os implantes da mandíbula. Os carregamentos de carga foram feitos em três pontos: no cantilever da prótese, no primeiro pré-molar e na incisal dos incisivos centrais inferiores. Para cada ponto de aplicação das cargas, fotografaram-se as mandíbulas nos lados de trabalho, de balanceio e na linha mediana, vestibular e na linha mediana também por lingual. Pelos resultados observados, quando as cargas foram aplicadas em regiões mais anteriores da prótese, as tensões nos implantes distais inclinados atenuaramse e as outras regiões da mandíbula apresentaram tensões menores e melhor distribuídas. As franjas também mostraram que a angulação dos implantes distais promoveu mudanças no eixo de rotação do conjunto implantes/prótese. Assim como verificou-se que o implante mais distal do lado de balanceio mostrou atuação conjunta com o implante distal do lado de trabalho nas mandíbulas com implantes axiais e, o mais distal do lado de balanceio nas mandíbulas com implantes inseridos segundo a técnica All-on-Four, mostrou tensão nos ápices, denotando função de estaca. Pela metodologia empregada foi possível concluir que, uma prótese total implantossuportada, segundo a técnica All-on-Four, apresentou melhor melhor dissipação das cargas oclusais e o lado de balanceio teve papel fundamental no auxílio à dissipação de cargas oclusais. / The All-on-Four technique was conceived in order to decrease the length of the cantilever in the rehabilitation of edentulous patients with implant-supported prosthesis. However, still persist questions related to the biomechanical behavior of implants and the proper technique All-on-Four, since issues such as peri-implant bone loss and failure of the prosthetic components are not yet clearly elucidated. The purpose of the study was to evaluate the dissipation of tensions in the Branemark implant-supported prosthesis and All-on-Four, under static occlusal load, and the role of the balancing side and the complex behavior of implants / prostheses. Six replicas of the human mandible were made in photoelastic resin, divided into two groups: one with four implants placed axially and parallel to each other in interforaminal space (Branemark jaws), and another four implants inserted according to the All-on-Four technique. It was made an implant-supported denture, so that would fit in all six jaws. The experiment was conducted with the aid of a rotating load device, which permitted visualization of the jaws from all angles, without changing the applied load. After the standardized setting of specimen in the device, the prosthesis was screwed onto the implants in the jaw. The cargo shipments were made on three points: the cantilever prosthesis, in the first premolar and the lower central incisor incisal. For each point of application of loads, photograph was taken from the work sides of the jaws, balancing and the midline, bucal view and the midline lingual also. By the observed results, when loads were applied to more anterior regions of the prosthesis, the stresses in the distal inclined implants attenuated and other regions of the mandible showed lower stresses and better distributed. The fringes also showed that the angulation of the distal implants promoted changes in the axis of rotation of the implant / prosthesis. As it was found that the most distal implantat on the balancing side showed joint action with the distal implant of the working side in the jaw with axial implants, and the most distal implant on the balancing side of jaw with implants inserted according to All-on Four technique, the tension showed apices, denoting stake function. For the methodology it was concluded that an implant-supported denture, according to the All-on-Four technique, had a better dissipation of occlusal loads and balancing side was fundamental hole in helping to dissipate occlusal loads.
64

"Estudo das formas e dimensões transversais dos arcos ortodônticos determinados por meio de três categorias diferentes de pontos de referência" / Study of the shapes and transversal dimensions of orthodontic arches as determined by three different categories of reference points

Lylian Kazumi Kanashiro 11 August 2006 (has links)
Verificando a importância da morfologia dos arcos dentários no tratamento ortodôntico, a proposta deste estudo foi avaliar e comparar as formas e dimensões de arcos de 30 indivíduos com oclusão normal e 30 com má-oclusão de Classe IIdivisão 1ª, geradas a partir de três categorias de pontos de referência. Foram demarcados nos modelos de estudo: os pontos médios das faces vestibulares dos dentes (1ª categoria de pontos); pontos no rebordo alveolar, perpendiculares aos anteriores e sobre a junção muco-gengival (2ª categoria de pontos); e pontos mesiais e distais das superfícies oclusais dos dentes. Todos os pontos foram digitalizados e convertidos automaticamente para o sistema de coordenadas x, y e z pela máquina de medidas tridimensional da Mitutoyo (modelo Crysta-Apex/C). Um software, especialmente desenvolvido para este trabalho, criou um conjunto de pontos de referência virtuais (3ª categoria de pontos) a partir dos pontos mesiais e distais das superfícies oclusais previamente demarcados nos modelos, que representou o fundo dos canais de encaixe de braquetes. Além disso, gerou curvaturas por meio de equações matemáticas (parábola, elipse, catenária e função beta) que se ajustaram, pelo método dos mínimos quadrados, às 3 diferentes categorias de pontos de referência, e mediu as dimensões transversais dentárias e dos rebordos alveolares. A seleção da equação matemática que melhor descreveu cada categoria de pontos de referência foi realizada por meio de avaliação do menor valor do erro médio. A curvatura do rebordo selecionada foi deslocada sobre o eixo y até tangenciar o ponto médio virtual do incisivo central mais anterior, simulando a inserção de um arco ortodôntico, e foram medidas as distâncias entre esta curvatura e os pontos médios virtuais dos outros dentes. Todos os dados foram organizados em tabelas de acordo com a categoria dos pontos de referência, os arcos (superior ou inferior) e o tipo de oclusão. Verificou-se que todas as dimensões transversais dentárias e dos rebordos superiores, e posteriores inferiores são estatisticamente maiores nos indivíduos com oclusão normal do que nos indivíduos com má-oclusão de Classe II; e que as distâncias transversais dos rebordos alveolares são estatisticamente maiores do que as dentárias. Quanto às formas dos arcos, a catenária, seguida da elipse, foram as que melhor descreveram as suas curvaturas, independentemente da categoria de pontos e do tipo de oclusão. As outras formas, como a parábola e a gerada pela função beta, foram observadas com baixo percentual de ocorrência. As formas dos arcos não caracterizaram diferencialmente os tipos de oclusão e as 3 categorias de pontos de referência estudadas. Praticamente todos os pontos médios virtuais apresentaram-se internamente posicionados em relação à curvatura do rebordo alveolar quando esta foi deslocada até o ponto médio virtual do incisivo central mais vestibularizado, sendo encontrados valores estatisticamente maiores no arco superior dos indivíduos com má-oclusão de Classe II-divisão 1ª. Este dado revela maior tendência a vestibularização dos dentes superiores nestes indivíduos, quando o rebordo alveolar é utilizado como guia para a construção do arco ortodôntico, embora as diferenças entre os grupos não nos pareçam clinicamente importantes. / Given the importance of dental arch morphology in orthodontic treatment, we have evaluated and compared, based on three categories of reference points, the shapes and dimensions of the arches of 30 subjects with normal occlusion and 30 subjects with Class II, division 1 malocclusions. .The points marked on the study casts were: the middle points of the buccal surfaces of teeth (first category of points); points on the alveolar ridge, perpendicular to those of the first category and on the mucogingival junction (second category of points); and mesial and distal points of the occlusal surfaces of the teeth. All points were digitized and automatically converted to the x, y and z system of coordinates by a three-dimensional measurement machine (Mitutoyo - Crysta-Apex/C model). A computer software program especially developed for our study created a set of virtual reference points (third category of points) based on the distal and mesial points on the occlusal surfaces previously marked on the casts, which represented the most inner point of the bracket slot. In addition, the software generated curvatures using mathematical equations that were adjusted to the three categories of reference points by the method of minimum squares, and measured the transversal dimensions of teeth and alveolar ridges. Selection of the mathematical equation that best described each category of reference points was performed by evaluating the smallest value for the mean error. The selected ridge curvature was shifted on the y-axis until it became tangential to the virtual middle point of the most anterior central incisor, simulating the insertion of an orthodontic arch, and the distances between this curvature and the virtual middle point on the other teeth were measured. All data were tabulated according to reference point category, arch (upper or lower), and type of occlusion. We observed that all transversal dimensions of teeth, upper ridges and lower posterior ridges were statistically greater in subjects with normal occlusion than in subjects with Class II malocclusions; and that the transversal distances of the alveolar ridges were statistically greater than those of the teeth. As to arch shape, the catenary, followed by the ellipse, were the shapes that best described the arch curvatures, regardless of reference point category and occlusion type. The other shapes, such as the parabola and the shape generated by the Beta function, were observed at lower frequencies. The arch shapes did not differentially characterize the several types of occlusion or the 3 reference point categories studied. Practically all virtual middle points were located internally to the curvature of the alveolar ridge when this curvature was shifted up to the virtual middle point of the most buccaly projected central incisor, and the subjects with Class II division 1 malocclusion were found to have statistically greater values for the upper arch. This observation reveals a greater trend for buccally projected upper teeth in these subjects when the alveolar ridge is used as a guide to construct the orthodontic arch, although the differences observed between the groups do not seem to be clinically important.
65

An?lise comparativa na influ?ncia da t?cnica de moldagem funcional em arcos parcialmente ed?ntulos sobre os pontos de contato oclusais, a integridade da fibromucosa e a extens?o da base da pr?tese

Dias, K?ssia de Carvalho 06 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:46Z (GMT). No. of bitstreams: 1 KassiaCD_DISSERT.pdf: 3074934 bytes, checksum: e11accf83a218e88932f4699f7d8e3bd (MD5) Previous issue date: 2012-12-06 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / There is a lack of clinical studies evaluating techniques of functional impression for partially edentulous arches. The aim of this double-blind non-randomized controlled clinical trial was to compare the efficacy of altered cast impression (ACI) and direct functional impression (DFI) techniques. The efficacy was evaluated regarding the number of occlusal units on denture teeth, mucosa integrity at 24-hour follow-up and denture base extension. The sample included 51 patients (female and male) with mean age of 58.96 years treated at Dental Department of UFRN. The patients, exhibiting edentulous maxilla and mandibular Kennedy class I, were divided into two groups (group ACI, n=29; group DFI, n=22). Clinical evaluation was based on the number of occlusal units on natural and/or artificial teeth, mucosa integrity at 24-hour follow-up, and denture base extension. Statistical analysis was conducted using the software SPSS 17.0? (SPSS Inc., Chicago, Illinois). Student T-test was used to reveal association between number of occlusal units and impression technique while chi-square test showed association between mucosa integrity and impression technique. Fischer s exact test was applied for association between denture base extension and impression technique at 95% level of significance. No significant difference was observed between the groups regarding number of occlusal units, mucosa integrity and denture base extension. The altered cast technique did not provide significant improvement in comparison to the direct technique when the number of occlusal units, mucosa integrity and denture base extension / A literatura cient?fica ? carente de estudos cl?nicos que avaliem a efici?ncia de t?cnicas de moldagem funcional para arcos parcialmente desdentados. Objetivou-se realizar um ensaio cl?nico controlado, n?o randomizado e duplo-cego, para comparar a efici?ncia da t?cnica de moldagem funcional do modelo alterado (TMMA) com a t?cnica de moldagem funcional direta (TMD), em rela??o ao n?mero de pontos de contato oclusais por unidade oclusal na instala??o de novas pr?teses, a integridade da fibromucosa na sess?o de controle de 24 horas e a extens?o da base de pr?tese. A amostra foi constitu?da por 51 pacientes, com m?dia de idade de 58,96 anos, portadores de arco maxilar totalmente desdentado e Classe I de Kennedy mandibular, de ambos os sexos, reabilitados nas cl?nicas do Departamento de Odontologia da Universidade Federal do Rio Grande do Norte. Os pacientes foram divididos em dois grupos: grupo TMMA (n=29) e Grupo TMD (n=22). As seguintes vari?veis foram utilizadas para as medidas cl?nicas: n?mero de pontos de contato oclusais por unidade oclusal, a integridade da fibromucosa no retorno programado de 24 horas e a extens?o da base da pr?tese. Para an?lise estat?stica, utilizou-se o programa SPSS 17.0? (SPSS Inc., Chicago, Illinois) e aplicou-se o teste t de Student para verificar a associa??o do n?mero de pontos de contato oclusais por unidade oclusal em dentes naturais e artificiais e a t?cnica de moldagem. Para verificar a associa??o entre a integridade da fibromucosa e a t?cnica, foi utilizado o teste quiquadrado. O teste exato de Fisher foi usado para verificar a associa??o entre a extens?o da base da pr?tese e a t?cnica, com confian?a estat?stica de 95%. N?o existiu diferen?a estatisticamente significativa entre os dois grupos quanto ? t?cnica de moldagem em rela??o ao n?mero de pontos de contato oclusais, ? integridade da fibromucosa e ? extens?o da base da pr?tese. A t?cnica de moldagem funcional do modelo alterado n?o oferece vantagens significativas, quando comparada ? t?cnica direta, em rela??o ? quantidade de n?mero de pontos de contato oclusais por unidade oclusal, ? integridade da fibromucosa e ? extens?o da base da pr?tese

Page generated in 0.0384 seconds