• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 2
  • Tagged with
  • 34
  • 24
  • 23
  • 17
  • 13
  • 11
  • 11
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Utilisation de BlobSeer pour le stockage de données dans les clouds : auto-adaptation, intégration, évaluation

Carpen-Amarie, Alexandra 15 December 2011 (has links) (PDF)
L'émergence de l'informatique dans les nuages met en avant de nombreux défis qui pourraient limiter l'adoption du paradigme Cloud. Tandis que la taille des données traitées par les applications Cloud augmente exponentiellement, un défi majeur porte sur la conception de solutions efficaces pour la gestion de données. Cette thèse a pour but de concevoir des mécanismes d'auto-adaptation pour des systèmes de gestion de données, afin qu'ils puissent répondre aux exigences des services de stockage Cloud en termes de passage à l'échelle, disponibilité et sécurité des données. De plus, nous nous proposons de concevoir un service de données qui soit à la fois compatible avec les interfaces Cloud standard dans et capable d'offrir un stockage de données à haut débit. Pour relever ces défis, nous avons proposé des mécanismes génériques pour l'auto-connaissance, l'auto-protection et l'auto-configuration des systèmes de gestion de données. Ensuite, nous les avons validés en les intégrant dans le logiciel BlobSeer, un système de stockage qui optimise les accès hautement concurrents aux données. Finalement, nous avons conçu et implémenté un système de fichiers s'appuyant sur BlobSeer, afin d'optimiser ce dernier pour servir efficacement comme support de stockage pour les services Cloud. Puis, nous l'avons intégré dans un environnement Cloud réel, la plate-forme Nimbus. Les avantages et les désavantages de l'utilisation du stockage dans le Cloud pour des applications réelles sont soulignés lors des évaluations effectuées sur Grid'5000. Elles incluent des applications à accès intensif aux données, comme MapReduce, et des applications fortement couplées, comme les simulations atmosphériques.
22

Utilisation de BlobSeer pour le stockage de données dans les Clouds: auto-adaptation, intégration, évaluation

Carpen-Amarie, Alexandra 15 December 2011 (has links) (PDF)
L'émergence de l'informatique dans les nuages met en avant de nombreux défis qui pourraient limiter l'adoption du paradigme Cloud. Tandis que la taille des données traitées par les applications Cloud augmente exponentiellement, un défi majeur porte sur la conception de solutions efficaces pour le stockage et la gestion de données. Cette thèse a pour but de concevoir des mécanismes d'auto-adaptation pour des systèmes de gestion de données, afin qu'ils puissent répondre aux exigences des services de stockage Cloud en termes de passage à l'échelle, disponibilité, fiabilité et sécurité des données. De plus, nous nous proposons de concevoir un service de données pour le Cloud qui soit à la fois compatible avec les interfaces standard dans le contexte du Cloud et capable d'offrir un stockage de données à haut débit. Pour relever ces défis, nous avons proposé des mécanismes génériques pour l'auto-connaissance, l'auto-protection et l'auto-configuration des systèmes de gestion de données. Ensuite, nous les avons validés en les intégrant dans le logiciel BlobSeer, un système de stockage de données qui optimise les accès hautement concurrents aux données. Finalement, nous avons conçu et implémenté un système de fichiers s'appuyant sur BlobSeer, afin d'optimiser ce dernier pour servir efficacement comme support de stockage pour les services Cloud. Puis, nous l'avons intégré dans un environnement Cloud réel, la plate-forme Nimbus. Les avantages et les désavantages de l'utilisation du stockage dans le Cloud pour des applications réelles sont soulignés lors des évaluations effectuées sur Grid'5000. Elles incluent des applications distribuées à accès intensif aux données, telles que les applications MapReduce, et des applications fortement couplées, telles que les simulations atmosphériques.
23

Gestion autonomique de performance, d'énergie et de qualité de service. Application aux réseaux filaires, réseaux de capteurs et grilles de calcul

Sharrock, Remi 08 December 2010 (has links) (PDF)
La motivation principale de cette thèse est de faire face à l'accroissement de la complexité des systèmes informatiques, qui, dans un futur proche ( de l'ordre de quelques années) risque fort d'être le principal frein à leur évolution et à leur développement. Aujourd'hui la tendance s'inverse et le coût de gestion humaine dépasse le coût des infrastructures matérielles et logicielles. De plus, l'administration manuelle de grands systèmes (applications distribuées, réseaux de capteurs, équipements réseaux) est non seulement lente mais aussi sujette à de nombreuses erreurs humaines. Un des domaines de recherche émergent est celui de l'informatique autonomique qui a pour but de rendre ces systèmes auto-gérés. Nous proposons une approche qui permet de décrire des politiques de gestion autonomiques de haut niveau. Ces politiques permettent au système d'assurer quatre propriétés fondamentales de l'auto-gestion: l'auto-guérison, l'auto-configuration, l'auto-protection et l'auto-optimisation. Nos contributions portent sur la spécification de diagrammes de description de politiques de gestion autonomiques appelés (S)PDD "(Sensor) Policy Description Diagrams". Ces diagrammes sont implémentés dans le gestionnaire autonomique TUNe et l'approche a été validée sur de nombreux systèmes: simulation électromagnétique répartie sur grille de calcul, réseaux de capteurs SunSPOT, répartiteur de calcul DIET. Une deuxième partie présente une modélisation mathématique de l'auto-optimisation pour un " datacenter ". Nous introduisons un problème de minimisation d'un critère intégrant d'une part la consommation électrique des équipements du réseau du " datacenter " et d'autre part la qualité de service des applications déployées sur le " datacenter ". Une heuristique permet de prendre en compte les contraintes dues aux fonctions de routage utilisées.
24

Cilia : un framework pour le développement d'applications de médiation autonomiques

Morand, Denis 05 November 2013 (has links) (PDF)
Cette thèse se situe dans le domaine de l'informatique orientée service. Elle propose un ESB (Enterprise Service Bus) autonomique, c'est-à-dire capable de s'autogérer sur un ensemble d'aspects. Cet ESB, nommé Cilia autonomique, permet de construire des applications de médiation sensibles au contexte. Précisément, la version autonomique de Cilia, que nous proposons, permet l'optimisation de l'utilisation des ressources de la plate-forme d'exécution et l'adaptation dynamique des chaînes de médiation au niveau de la configuration et de la topologie. Notre framework permet également de présenter à tout moment un modèle simplifié des phénomènes liés à l'exécution des chaînes et, ainsi, de faciliter le raisonnement et la prise de décisions d'adaptation. Les travaux de cette thèse ont été validés dans le cadre de l'informatique pervasive. En particulier, Cilia autonomique a été utilisé et instrumenté pour la mise en œuvre d'applications de maintien à domicile et de suivi de la santé des usagers. Les résultats sont disponibles en open source.
25

Plateforme autonomique dirigée par les modèles pour la construction d'interfaces multimodales dans les environnements pervasifs / Model-Driven Autonomic Framework for Building Multimodal Interfaces in Pervasive Environments

Avouac, Pierre-Alain 07 February 2013 (has links)
La construction d’interfaces homme-machine au dessus d’applications complexes soulève aujourd’hui des problèmes importants et requiert des efforts de recherche conséquents et soutenus. Il s’agit en effet d’aborder des technologies de plus en plus diverses et complexes de façon à construire des interfaces modulaires, évolutives et tirant profits des récents progrès dans les domaines de la programmation et des intergiciels. Il s’agit également de permettre à des non informaticiens, spécialistes de l’ergonomie, de définir et de mettre en place des interfaces appropriées. L’approche orientée service (Service-oriented Computing - SOC) constitue une avancée récente en Génie Logiciel. Cette approche promeut la mise en place de solutions modulaires et dynamiques permettant de faire évoluer, possiblement à l’exécution, les interfaces. L’approche orientée service est très prometteuse et de nombreux projets de recherche sont en cours dans les domaines de l’intégration d’entreprise, des équipements mobiles ou encore de l’informatique pervasive. L’approche orientée service demeure néanmoins complexe et demande un haut niveau d’expertise. Elle est difficilement accessible par des informaticiens non formés et totalement hors de portée des ingénieurs d’autres métiers, ergonomes par exemple. L’approche proposée dans cette thèse est de construire un atelier manipulant des services IHM abstraits. Ces services abstraits décrivent leurs fonctionnalités et leurs dépendances à un haut niveau d’abstraction. Ils peuvent ainsi être composés de façon plus aisée par des ingénieurs non experts en SOC. Le rôle de l’atelier est ensuite d’identifier des services concrets, implantant les services abstraits, de les composer en générant le code nécessaire (glue code) et de les déployer sur une plate-forme d’exécution. Un deuxième point concerne la spécialisation de l’atelier. Il est effet important de proposer un langage de composition de services proches des concepts métiers manipulés par les experts, notamment les ergonomes. Un tel langage se base sur les concepts métiers et intègre les contraintes de composition propres au domaine. L’approche actuelle passe par l’utilisation de méta-modèles, exprimant les connaissances métier, pour la spécialisation de l’atelier. / N pervasive environments, with the proliferation of communicating devices in the environments (e.g., remoter controller, gamepad, mobile phone, augmented object), the users will express their needs or desires to an enormous variety of services with a multitude of available interaction modalities, expecting concurrently the environment and its equipment to react accordingly. Addressing the challenge of dynamic management at runtime of multimodal interaction in pervasive environments, our contribution is dedicated to software engineering of dynamic multimodal interfaces by providing: a specification language for multimodal interaction, an autonomic manager and an integration platform. The autonomic manager uses models to generate and maintain a multimodal interaction adapted to the current conditions of the environment. The multimodal interaction data-flow from input devices to a service is then effectively realized by the integration platform. Our conceptual solution is implemented by our DynaMo platform that is fully operational and stable. DynaMo is based on iPOJO, a dynamic service-oriented component framework built on top of OSGi and on Cilia, a component-based mediation framework.
26

Placement autonomique de machines virtuelles sur un système de stockage hybride dans un cloud IaaS / Autonomic virtual machines placement on hybrid storage system in IaaS cloud

Ouarnoughi, Hamza 03 July 2017 (has links)
Les opérateurs de cloud IaaS (Infrastructure as a Service) proposent à leurs clients des ressources virtualisées (CPU, stockage et réseau) sous forme de machines virtuelles (VM). L’explosion du marché du cloud les a contraints à optimiser très finement l’utilisation de leurs centres de données afin de proposer des services attractifs à moindre coût. En plus des investissements liés à l’achat des infrastructures et de leur coût d’utilisation, la consommation énergétique apparaît comme un point de dépense important (2% de la consommation mondiale) et en constante augmentation. Sa maîtrise représente pour ces opérateurs un levier très intéressant à exploiter. D’un point de vue technique, le contrôle de la consommation énergétique s’appuie essentiellement sur les méthodes de consolidation. Or la plupart d'entre elles ne prennent en compte que l’utilisation CPU des machines physiques (PM) pour le placement de VM. En effet, des études récentes ont montré que les systèmes de stockage et les E/S disque constituent une part considérable de la consommation énergétique d’un centre de données (entre 14% et 40%). Dans cette thèse nous introduisons un nouveau modèle autonomique d’optimisation de placement de VM inspiré de MAPE-K (Monitor, Analyze, Plan, Execute, Knowledge), et prenant en compte en plus du CPU, les E/S des VM ainsi que les systèmes de stockage associés. Ainsi, notre première contribution est relative au développement d’un outil de trace des E/S de VM multi-niveaux. Les traces collectées alimentent, dans l’étape Analyze, un modèle de coût étendu dont l’originalité consiste à prendre en compte le profil d’accès des VM, les caractéristiques du système de stockage, ainsi que les contraintes économiques de l’environnement cloud. Nous analysons par ailleurs les caractéristiques des deux principales classes de stockage, pour aboutir à un modèle hybride exploitant au mieux les avantages de chacune. En effet, les disques durs magnétiques (HDD) sont des supports de stockage à la fois énergivores et peu performants comparés aux unités de calcul. Néanmoins, leur prix par gigaoctet et leur longévité peuvent jouer en leur faveur. Contrairement aux HDD, les disques SSD à base de mémoire flash sont plus performants et consomment peu d’énergie. Leur prix élevé par gigaoctet et leur courte durée de vie (comparés aux HDD) représentent leurs contraintes majeures. L’étape Plan a donné lieu, d’une part, à une extension de l'outil de simulation CloudSim pour la prise en compte des E/S des VM, du caractère hybride du système de stockage, ainsi que la mise en oeuvre du modèle de coût proposé dans l'étape Analyze. Nous avons proposé d’autre part, plusieurs heuristiques se basant sur notre modèle de coût et que nous avons intégrées dans CloudSim. Nous montrons finalement que notre approche permet d’améliorer d’un facteur trois le coût de placement de VM obtenu par les approches existantes. / IaaS cloud providers offer virtualized resources (CPU, storage, and network) as Virtual Machines(VM). The growth and highly competitive nature of this economy has compelled them to optimize the use of their data centers, in order to offer attractive services at a lower cost. In addition to investments related to infrastructure purchase and cost of use, energy efficiency is a major point of expenditure (2% of world consumption) and is constantly increasing. Its control represents a vital opportunity. From a technical point of view, the control of energy consumption is mainly based on consolidation approaches. These approaches, which exclusively take into account the CPU use of physical machines (PM) for the VM placement, present however many drawbacks. Indeed, recent studies have shown that storage systems and disk I/O represent a significant part of the data center energy consumption (between 14% and 40%).In this thesis we propose a new autonomic model for VM placement optimization based on MAPEK (Monitor, Analyze, Plan, Execute, Knowledge) whereby in addition to CPU, VM I/O and related storage systems are considered. Our first contribution proposes a multilevel VM I/O tracer which overcomes the limitations of existing I/O monitoring tools. In the Analyze step, the collected I/O traces are introduced in a cost model which takes into account the VM I/O profile, the storage system characteristics, and the cloud environment constraints. We also analyze the complementarity between the two main storage classes, resulting in a hybrid storage model exploiting the advantages of each. Indeed, Hard Disk Drives (HDD) represent energy-intensive and inefficient devices compared to compute units. However, their low cost per gigabyte and their long lifetime may constitute positive arguments. Unlike HDD, flash-based Solid-State Disks (SSD) are more efficient and consume less power, but their high cost per gigabyte and their short lifetime (compared to HDD) represent major constraints. The Plan phase has initially resulted in an extension of CloudSim to take into account VM I/O, the hybrid nature of the storage system, as well as the implementation of the previously proposed cost model. Secondly, we proposed several heuristics based on our cost model, integrated and evaluated using CloudSim. Finally, we showed that our contribution improves existing approaches of VM placement optimization by a factor of three.
27

Towards Autonomic and Cognitive IoT Systems, Application to Patients’ Treatments Management / Vers les systèmes IoT autonomiques et cognitifs, application pour la gestion des traitements des patients

Mezghani, Emna 15 December 2016 (has links)
Dans cette thèse, nous proposons une méthodologie basée sur les modèles pour gérer la complexité de la conception des systèmes autonomiques cognitifs intégrant des objets connectés. Cette méthodologie englobe un ensemble de patrons de conception dont nous avons défini pour modéliser la coordination dynamique des processus autonomiques pour gérer l’évolution des besoins du système, et pour enrichir les systèmes avec des propriétés cognitives qui permettent de comprendre les données et de générer des nouvelles connaissances. De plus, pour gérer les problèmes reliés à la gestion des big data et à la scalabilité du système lors du déploiement des processus, nous proposons une plate-forme sémantique supportant le traitement des grandes quantités de données afin d’intégrer des sources de données distribuées et hétérogènes déployées sur le cloud pour générer des connaissances qui seront exposées en tant que service (KaaS). Comme application de nos contributions, nous proposons un système cognitif prescriptif pour la gestion du plan de traitement du patient. Ainsi, nous élaborons des modèles ontologiques décrivant les capteurs et le contexte du patient, ainsi que la connaissance médicale pour la prise de décision. Le système proposé est évalué de point de vue clinique en collaborant avec des experts médicaux, et de point de vue performance en proposant des différentes configurations dans le KaaS. / In this thesis, we propose a collaborative model driven methodology for designing Autonomic Cognitive IoT systems to deal with IoT design complexity. We defined within this methodology a set of autonomic cognitive design patterns that aim at (1) delineating the dynamic coordination of the autonomic processes to deal with the system's context changeability and requirements evolution at run-time, and (2) adding cognitive abilities to IoT systems to understand big data and generate new insights. To address challenges related to big data and scalability, we propose a generic semantic big data platform that aims at integrating heterogeneous distributed data sources deployed on the cloud and generating knowledge that will be exposed as a service (Knowledge as a Service--KaaS). As an application of the proposed contributions, we instantiated and combined a set of patterns for the development of prescriptive cognitive system for the patient treatment management. Thus, we elaborated two ontological models describing the wearable devices and the patient context as well as the medical knowledge for decision-making. The proposed system is evaluated from the clinical prescriptive through collaborating with medical experts, and from the performance perspective through deploying the system within the KaaS following different configurations
28

Cross-layer self-diagnosis for services over programmable networks / Auto-diagnostic multi-couche pour services sur réseaux programmables

Sánchez Vílchez, José Manuel 07 July 2016 (has links)
Les réseaux actuels servent millions de clients mobiles et ils se caractérisent par équipement hétérogène et protocoles de transport et de gestion hétérogènes, et des outils de gestion verticaux, qui sont très difficiles à intégrer dans leur infrastructure. La gestion de pannes est loin d’être automatisée et intelligent, ou un 40 % des alarmes sont redondantes et seulement un 1 ou 2% des alarmes sont corrélées au plus dans un centre opérationnel. Ça indique qu’il y a un débordement significatif des alarmes vers les adminis-trateurs humains, a comme conséquence un haut OPEX vue la nécessité d’embaucher de personnel expert pour accomplir les tâches de gestion de pannes. Comme conclusion, le niveau actuel d’automatisation dans les tâches de gestion de pannes dans réseaux télécoms n’est pas adéquat du tout pour adresser les réseaux programmables, lesquels promettent la programmation des ressources et la flexibilité afin de réduire le time-to-market des nouveaux services. L’automatisation de la gestion des pannes devient de plus en plus nécessaire avec l’arrivée des réseaux programmables, SDN (Software-Defined Networking), NFV (Network Functions Virtualization) et le Cloud. En effet, ces paradigmes accélèrent la convergence entre les domaines des réseaux et la IT, laquelle accélère de plus en plus la transformation des réseaux télécoms actuels en menant à repenser les opérations de gestion de réseau et des services, en particulier les opérations de gestion de fautes. Cette thèse envisage l’application des principes d’autoréparation en infrastructures basées sur SDN et NFV, en focalisant sur l’autodiagnostic comme facilitateur principal des principes d’autoréparation. Le coeur de cette thèse c’est la conception d’une approche de diagnostic qui soit capable de diagnostiquer de manière continuée les services dynamiques virtualisés et leurs dépendances des ressources virtuels (VNFs et liens virtuels) mais aussi les dépendances de ceux ressources virtuels de la infrastructure physique en-dessous, en prenant en compte la mobilité, la dynamicite, le partage de ressources à l’infrastructure en-dessous / Current networks serve billions of mobile customer devices. They encompass heterogeneous equipment, transport and manage-ment protocols, and vertical management tools, which are very difficult and costly to integrate. Fault management operations are far from being automated and intelligent, where around 40% of alarms are redundant only around 1-2% of alarms are correlated at most in a medium-size operational center. This indicates that there is a significant alarm overflow for human administrators, which inherently derives in high OPEX due to the increasingly need to employ high-skilled people to perform fault management tasks. In conclusion, the current level of automation in fault management tasks in Telcos networks is not at all adequate for programmable networks, which promise a high degree of programmability and flexibility to reduce the time-to-market. Automation on fault management is more necessary with the advent of programmable networks, led by with SDN (Software-Defined Networking), NFV (Network Functions Virtualization) and the Cloud. Indeed, the arise of those paradigms accelerates the convergence between networks and IT realms, which as consequence, is accelerating faster and faster the transformation of cur-rent networks leading to rethink network and service management and operations, in particular fault management operations. This thesis envisages the application of self-healing principles in SDN and NFV combined infrastructures, by focusing on self-diagnosis tasks as main enabler of self-healing. The core of thesis is to devise a self-diagnosis approach able to diagnose at run-time the dynamic virtualized networking services and their dependencies from the virtualized resources (VNFs and virtual links) but also the dependencies of those virtualized resources from the underlying network infrastructure, taking into account the mobility, dynamicity, and sharing of resources in the underlying infrastructure
29

Mind the rhythm : associations between cardiac electrophysiology and cognition in healthy older adults and patients with atrial fibrillation

Vrinceanu, Tudor 08 1900 (has links)
Il existe une association étroite entre la santé cardiovasculaire et la santé cognitive au cours du vieillissement. Bien que la recherche dans le domaine de la santé cardiovasculaire soit vaste, le lien entre l'électrophysiologie cardiaque et la cognition est peu étudié. La présente thèse met en évidence les liens entre l'électrophysiologie cardiaque et la cognition en examinant la régulation autonomique chez les individus sains et des marqueurs de maladie chez les patients souffrant de fibrillation auriculaire (FA ; maladie du rythme cardiaque la plus prévalente). Les résultats présentés dans le chapitre 2 démontrent pour une première fois qu'un marqueur de repolarisation cardiaque, le QTcD, est lié aux performances cognitives (fonctions globales et exécutives) chez des personnes âgées sédentaires en bonne santé. Ces observations étaient plus évidentes chez les personnes présentant des valeurs élevées de QTcD, suggérant que des altérations plus importantes du rythme cardiaque pourraient avoir une association plus forte avec les performances cognitives. Les résultats présentés au chapitre 3 montrent que chez les patients souffrant de FA, une plus grande morbidité (mesurée par le sous-type de FA) serait associée à une performance cognitive plus faible (fonctions globales et exécutives). Cette même étude démontre que le volume de l'oreillette gauche agît comme facteur modérateur de l’association entre le sous-type de FA et la performance cognitive. Ceci suggère que plus l'arythmie est sévère, plus le déficit cognitif observé est important. Le chapitre 4 présente les résultats d'une étude pilote portant sur les changements dans les performances cognitives et l'oxygénation régionale du tissu cérébral chez les patients souffrant de FA qui subissent une cardioversion électrique (une procédure visant à rétablir du rythme sinusal). Les résultats de cette étude pilote montrent qu'un tel devis est effectivement réalisable et pourrait permettre de détecter des changements cognitifs dans cet échantillon. Bien que la modification de l'oxygénation du tissu cérébral en lien avec la cardioversion n’ait pas été démontrée pour le moment, des changements au niveau de la cognition ont été observé, ce qui pourrait être partiellement expliqué par la réduction des symptômes liés à la FA post-cardioversion. Parmi toutes les capacités cognitives, la flexibilité (mesurée par le Trail-Making Test) semble être plus sensible aux détériorations du rythme cardiaque, tant chez les individus sains que chez les patients souffrant de FA, dans toutes les études présentées. Les résultats sont discutés dans le contexte d'un continuum cœur-cerveau dans lequel les détériorations du cœur ou du cerveau peuvent avoir des impacts bidirectionnels et altérer davantage le fonctionnement de cet axe. Les orientations futures porteront sur les avantages potentiels de la prévention cognitive par l'exercice et la stimulation cognitive chez les personnes présentant des détériorations électrophysiologiques cardiaques. / There is a close association between cardiovascular and cognitive health in aging. While the cardiovascular health domain is vast, the link between cardiac electrophysiology and cognition is understudied. The present thesis will bring evidence linking cardiac electrophysiology and cognition by looking at autonomic regulation in healthy older individuals and disease markers in patients with atrial fibrillation (AF; most prevalent disease of heart rhythm). Chapter 2 shows for the first time that a cardiac repolarization marker, QTcD, is linked to cognitive performance (global and executive functions) in healthy sedentary older individuals. This relationship was more evident in individuals with elevated QTcD values suggesting that higher impairments in cardiac rhythm might have stronger association with cognitive performance. Results presented in Chapter 3 show that among patients with AF, higher disease burden (as measured by the subtype of AF) was associated with lower cognitive performance (global and executive functions). The study also found that the left atrial volume was a moderator of this association between AF subtype and cognitive performance. This shows that the more severe the condition is the higher the cognitive deficit observed. Chapter 4 shows the results of a pilot study investigating the changes in cognitive performance and regional cerebral tissue oxygenation in AF patients undergoing electrical cardioversion (a sinus rhythm restoration procedure). The pilot results show that such a study is indeed feasible and could detect cognitive changes in this sample. While the change in cerebral tissue oxygenation is unconclusive at this moment, the recorded change in cognition could partially be explained by the reduction in AF related symptoms. Among all cognitive abilities, switching (as measured with the Trail-Making Test) appears to be more sensitive to deteriorations in heart rhythm both in healthy individuals and patients with AF across all studies presented. The results are discussed in the context of a heart-brain continuum in which deteriorations from either the heart or the brain can have bidirectional impacts and further impair the functioning of this axis. Future directions will address the potential benefit of cognitive prevention through exercise and cognitive stimulation in older individuals with cardiac electrophysiological deteriorations.
30

The role of the insula in heart rate variability

Tran, Thi Phuoc Yen 12 1900 (has links)
Des preuves cumulatives soutiennent le rôle de l'insula dans la régulation autonomique cardiaque et son dysfonctionnement pourrait être impliqué dans la physiopathologie de la mort subite et inexpliquée en épilepsie (MSIE –SUDEP en anglais). La variabilité de la fréquence cardiaque (VFC) est un outil simple et fiable pour évaluer la fonction autonomique; il est également considéré comme un prédicteur potentiel de la tachycardie ventriculaire et de la mort subite chez les patients après un infarctus du myocarde. Au cours des deux dernières décennies, la VFC a suscité beaucoup d'intérêt dans le monde de l'épilepsie. Toutefois, même si plusieurs études ont tenté d'évaluer les changements de VFC dans différentes formes d'épilepsie, les résultats ont été hétérogènes voire paradoxaux de sorte que son utilité en tant que marqueur de la MSIE est loin d’être concluant. Notons que la majorité des études ont porté sur l’épilepsie temporale. Aucune étude n’a étudié les changements de la fonction autonomique cardiaque dans l'épilepsie insulo-operculaire (EIO). Il est encore incertain si une chirurgie d’épilepsie insulaire peut accélérer la dysfonction autonomique inhérente. Dans cette étude, nous visons à étudier les changements de la VFC interictale chez les patients avec EIO. Nous avons en outre évalué l'effet de la chirurgie insulo-operculaire sur ces modifications de la VFC. Quatorze patients avec une EIO et un bon résultat post-chirurgie insulo-operculaire (Engel I-II) ont été recrutés pour cette étude. Quatorze patients appariés pour l'âge et le sexe atteints d'épilepsie du lobe temporal (ELT) et exempts de crise après une lobectomie temporale antérieure et 28 individus en bonne santé appariés selon l'âge et le sexe ont également été identifiés pour les besoins de l’étude. La VFC dans le domaine temporel RMSSD (root mean square of successive RR interval differences, pNN50 (percentage of successive RR intervals that differ by more than 50ms) et le domaine fréquentiel LF (low frequency) et HF (high frequency) ont été étudiés dans les périodes préopératoire et postopératoire (6-204 mois). La VFC avant la chirurgie des patients épileptiques fut calculée à partir des enregistrements EKG obtenus simultanément aux enregistrements vidéo-EEGs effectués dans le cadre de leur évaluation préchirurgicale. La VFC après la chirurgie fut calculée chez tous les patients et les sujets sains à partir d’un EKG de repos d'une durée d’une heure au laboratoire. Le score d’inventaire des risques de MSIE (le score SUDEP-7) a été calculé à partir des données cliniques obtenues dans le dossier médical de chaque patient. Les résultats n'ont montré aucune différence statistiquement significative dans toutes les mesures de VFC entre les groupes de patients avec EIO, de patients avec ELT avant la chirurgie et de sujets sains. Chez les patients avec EIO, le score SUDEP-7 variant de 1 à 6 (moyenne de 2,9; SD :1,2) était positivement corrélé avec le pNN50 (r = 0,671; p = 0,009 et Ln (RMSSD) (r = 0,591; p = 0,026). En postopératoire, les mesures de la VFC n'étaient pas statistiquement différentes des valeurs préopératoires ou de celles des témoins. Nous avons mené une analyse exploratoire dans laquelle nous avons stratifié les patients avec EIO en deux sous-groupes : un premier groupe (1a) dont les valeurs préopératoires de Ln (RMSSD) étaient inférieures à 3,52 (valeur moyenne de notre échantillon sain) et un second groupe (1b) dont les valeurs préopératoires étaient au-dessus. En préopératoire, dans le groupe 1a, toutes les valeurs du domaine temporel et fréquentiel (LnRMSSD, pNN50, LnLF et LnHF) étaient significativement inférieures à celles du groupe témoin (p <0,01), tandis que dans le groupe 1b, seules les valeurs du domaine temporel (LnRMSSD et pNN50) étaient significativement plus élevées que ceux du groupe témoin (p <0,01). Dans les deux groupes, les valeurs de la VFC avaient tendance à se normaliser après l'opération. En revanche, la lobectomie temporale antérieure des patients avec ELT n'a pas modifié les valeurs de HRV. Ces résultats préliminaires suggèrent que dans les EIO réfractaires, la VFC peut être soit diminuée au niveau du tonus sympathique et parasympathique, soit augmentée au niveau du tonus parasympathique. L'augmentation du tonus parasympathique est possiblement inquiétante puisqu’elle était corrélée positivement avec le score SUDEP-7. Une operculo-insulectomie n'a pas affecté négativement la VFC; au contraire, une chirurgie réussie semble entraîner une certaine ‘normalisation’ de l’HRV. Une confirmation avec un échantillon plus grand est nécessaire. / Cumulative evidence supports the role of the insula in cardiac autonomic regulation whose dysfunction may be involved in the pathophysiology of sudden unexpected death in epilepsy (SUDEP). Heart rate variability (HRV) is a simple and reliable tool to assess autonomic function; it is even considered a potential predictor of ventricular tachycardia and sudden death in patients after myocardial infarction. Over the last two decades, heart rate variability (HRV) has also received much interest in epilepsy research. Several studies have tried to assess HRV changes in different epilepsy types but the results have been heterogeneous and sometimes contradictory; its role as a marker of SUDEP remains uncertain. Of note, most studies involved TLE patients and TLE surgeries; none have looked at HRV changes in insulo-opercular epilepsy (IOE) and how insular resection can affect autonomic function. In this study, we aimed to investigate changes in interictal HRV in IOE. We further evaluated the effect of insulo-opercular surgery on these HRV changes. Fourteen IOE patients who had a good outcome (Engel I-II) after an insulo-opercular surgery were enrolled in this study. Fourteen age- and sex-matched patients with temporal lobe epilepsy (TLE) who were seizure-free after temporal lobectomy and 28 age- and sex-matched healthy individuals were also included. HRV measurements including time domain root mean square of successive RR interval differences (RMSSD) and percentage of successive RR intervals that differ by more than 50ms (pNN50) and frequency domain low-frequency (LF) and high-frequency (HF) parameters were carried out in pre- and post-operative periods (6-204 months). Presurgical HRV values for epileptic patients were calculated using EKG obtained simultaneously with video-EEG recordings during the presurgical evaluation. HRV of healthy individuals and post-surgical HRV from all operated epileptic patients were calculated from a 1-hour resting electrocardiogram at the laboratory. We also collected the patients’ presurgical data to calculate the SUDEP-7 risk inventory score. Findings showed no statistically significant differences in all HRV measurements between groups of IOE patients, TLE patients before the surgery, and healthy controls. In IOE patients, the SUDEP-7 score ranged from 1 to 6 (mean 2,9; SD: 1,6) and was positively correlated with pNN50 (r=0,671; p<0,009) and LnRMSSD (r=0,591; p<0,026). Postoperatively, HRV measurements were not statistically different from either preoperative values or those of controls. We conducted exploratory analyses where we stratified IOE patients into those whose preoperative LnRMSSD values were below (Group 1a) versus above (Group 1b) a cut-off threshold of 3,52 (mean value of our healthy sample). Preoperatively, in Group 1a, all time and frequency domain values (LnRMSSD, pNN50, LnLF, and LnHF) were significantly lower than those of controls (p<0,01) while in Group 1b, only time-domain values (LnRMSSD and pNN50) were significantly higher than those of control subjects (p<0,01). In both groups, HRV values tended to normalize postoperatively. In contrast, anterior temporal lobectomy for TLE patients did not alter HRV values. Our preliminary results suggest that in refractory IOE, HRV may be either decreased globally in sympathetic and parasympathetic tones or increased in parasympathetic tone. The increase in parasympathetic tone observed preoperatively may be of clinical concern as it was positively correlated with the SUDEP-7 score. The insulo-opercular resection did not affect the HRV; successful surgery might even have a good impact on HRV changes. Confirmation with a larger sample size is necessary.

Page generated in 0.0923 seconds