• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 356
  • 5
  • 1
  • Tagged with
  • 362
  • 351
  • 199
  • 195
  • 138
  • 123
  • 120
  • 94
  • 90
  • 67
  • 54
  • 52
  • 51
  • 48
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Medidas de concentração de radônio proveniente de argamassas de cimento portland, gesso e fosfogesso / Measurements of radon concentration from portland cement, gypsum and phosphogypsum mortars

Narloch, Danielle Cristine 14 September 2015 (has links)
CAPES / O cimento Portland é bastante empregado na construção civil e apresenta em sua composição o gesso natural. Para minimizar custos é possível substituir parte do gesso desta composição pelo fosfogesso. O fosfogesso é um resíduo gerado a partir da produção dos fertilizantes e é constituído, essencialmente, por cálcio dihidratado e algumas impurezas, como fluoretos, metais em geral e radionuclídeos. Atualmente, toneladas de fosfogesso são armazenadas à céu aberto próximo das indústrias de fertilizantes, causando a contaminação do meio ambiente. O elemento 226Ra, presente nesses materiais, ao passar pela série de decaimento radioativo, transforma-se em gás 222Rn. Esse gás, ao ser inalado pode decair dentro dos pulmões e neste caso, os seus produtos depositam-se nas paredes pulmonares ocasionando exposição à radiação, podendo ser um potencial causador de câncer pulmonar. Dessa forma, o objetivo desta pesquisa foi medir os níveis de concentração de 222Rn em corpos de prova de argamassa de cimento Portland, de gesso e de fosfogesso provenientes do Estado do Paraná, além de caracterizar o material e estimar a concentração de radônio em um ambiente de convívio humano hipotético construído com paredes destes materiais. Para as medidas de atividade do 222Rn foi utilizado o monitor AlphaGUARD (Saphymo GmbH). A análise qualitativa e quantitativa foi realizada por meio da espectrometria gama e da EDXRF com tubos de alvos de Au e Ag (AMPTEK), e com alvo de Mo (ARTAX) e os ensaios mecânicos com equipamento de raios X (Gilardoni) e com a prensa mecânica (EMIC). Os valores médios da atividade do radônio no ar obtidos pelo estudo dos materiais armazenados no recipiente foram de 854 ± 23 Bq/m3, 60,0 ± 7,2 Bq/m3 e 52,9 ± 5,4 Bq/m3 para argamassas de cimento Portland, de gesso e de fosfogesso, respectivamente. Estes resultados extrapolados para o ambiente hipotético de 36 m3 com paredes revestidas com os materiais foram de 3366 ± 91 Bq/m3, 237 ± 28 Bq/m3 e 208 ± 21 Bq/m3 para argamassas de cimento Portland, gesso e fosfogesso. Considerando o limite de 300 Bq/m3 estabelecido pela ICRP, observa-se que, para o revestimento de cimento Portland a exposição não é segura e requer alguns procedimentos de mitigação específicos. A partir da espectrometria gama foi calculado o valor do rádio equivalente (Raeq) para as argamassas de cimento Portland, gesso e fosfogesso que resultou em 78,2 ± 0,9 Bq/kg; 58,2 ± 0,9 Bq/kg e 68,2 ± 0,9 Bq/kg, respectivamente. Os valores do Raeq das amostras encontram-se inferiores ao limite máximo de 370 Bq/kg. Em relação a análise qualitativa e quantitativa das amostras por EDXRF, os resultados permitiram identificar e quantificar os elementos que compõe as amostras como o Ca, S, Fe, entre outros. / Portland cement being very common construction material has in its composition the natural gypsum. To decrease the costs of manufacturing, the cement industry is substituting the gypsum in its composition by small quantities of phosphogypsum, which is the residue generated by the production of fertilizers and consists essentially of calcium dihydrate and some impurities, such as fluoride, metals in general, and radionuclides. Currently, tons of phosphogypsum are stored in the open air near the fertilizer industries, causing contamination of the environment. The 226 Ra present in these materials, when undergoes radioactive decay, produces the 222Rn gas. This radioactive gas, when inhaled together with its decay products deposited in the lungs, produces the exposure to radiation and can be a potential cause of lung cancer. Thus, the objective of this study was to measure the concentration levels of 222Rn from cylindrical samples of Portland cement, gypsum and phosphogypsum mortar from the state of Paraná, as well as characterizer the material and estimate the radon concentration in an environment of hypothetical dwelling with walls covered by such materials. Experimental setup of 222Rn activity measurements was based on AlphaGUARD detector (Saphymo GmbH). The qualitative and quantitative analysis was performed by gamma spectrometry and EDXRF with Au and Ag targets tubes (AMPTEK), and Mo target (ARTAX) and mechanical testing with x- ray equipment (Gilardoni) and the mechanical press (EMIC). Obtained average values of radon activity from studied materials in the air of containers were of 854 ± 23 Bq/m3, 60,0 ± 7,2 Bq/m3 e 52,9 ± 5,4 Bq/m3 for Portland cement, gypsum and phosphogypsum mortar, respectively. These results extrapolated into the volume of hypothetical dwelling of 36 m3 with the walls covered by such materials were of 3366 ± 91 Bq/m3, 237 ± 28 Bq/m3 e 208 ± 21 Bq/m3for Portland cement, gypsum and phosphogypsum mortar, respectively. Considering the limit of 300 Bq/m3 established by the ICRP, it could be concluded that the use of Portland cement plaster in dwellings is not secure and requires some specific mitigation procedure. Using the results of gamma spectrometry there were calculated the values of radium equivalent activity concentrations (Raeq) for Portland cement, gypsum and phosphogypsum mortar, which were obtained equal to 78,2 ± 0,9 Bq/kg; 58,2 ± 0,9 Bq/kg e 68,2 ± 0,9 Bq/kg, respectively. All values of radium equivalent activity concentrations for studied samples are below the maximum level of 370 Bq/kg. The qualitative and quantitative analysis of EDXRF spectra obtained with studied mortar samples allowed to evaluate quantitate and the elements that constitute the material such as Ca, S, Fe, and others.
332

Uso da análise de discriminante linear em conjunto com a transformada wavelet discreta no reconhecimento de espículas / The linear discriminant analysis usage combined with the discrete wavelet transform in spike detection

Pacola, Edras Reily 18 December 2015 (has links)
CAPES / Pesquisadores têm concentrado esforços, nos últimos 20 anos, aplicando a transformada wavelet no processamento, filtragem, reconhecimento de padrões e na classificação de sinais biomédicos, especificamente em sinais de eletroencefalografia (EEG) contendo eventos característicos da epilepsia, as espículas. Várias famílias de wavelets-mães foram utilizadas, mas sem um consenso sobre qual wavelet-mãe é a mais adequada para essa finalidade. Os sinais utilizados apresentam uma gama muito grande de eventos e não possuem características padronizadas. A literatura relata sinais de EEG amostrados entre 100 a 600 Hz, com espículas variando de 20 a 200 ms. Nesse estudo foram utilizadas 98 wavelets. Os sinais de EEG foram amostrados de 200 a 1 kHz. Um neurologista marcou um conjunto de 494 espículas e um conjunto de 1500 eventos não-espícula. Esse estudo inicia avaliando a quantidade de decomposições wavelets necessárias para a detecção de espículas, seguido pela análise detalhada do uso combinado de wavelets-mães de uma mesma família e entre famílias. Na sequência é analisada a influência de descritores e o uso combinado na detecção de espículas. A análise dos resultados desses estudos indica que é mais adequado utilizar um conjunto de wavelets-mães, com vários níveis de decomposição e com vários descritores, ao invés de utilizar uma única wavelet-mãe ou um descritor específico para a detecção de espículas. A seleção desse conjunto de wavelets, de níveis de decomposição e de descritores permite obter níveis de detecção elevados conforme a carga computacional que se deseje ou a plataforma computacional disponível para a implementação. Como resultado, esse estudo atingiu níveis de desempenho entre 0,9936 a 0,9999, dependendo da carga computacional. Outras contribuições desse estudo referem-se à análise dos métodos de extensão de borda na detecção de espículas; e a análise da taxa de amostragem de sinais de EEG no desempenho do classificador de espículas, ambos com resultados significativos. São também apresentadas como contribuições: uma nova arquitetura de detecção de espículas, fazendo uso da análise de discriminante linear; e a apresentação de um novo descritor, energia centrada, baseado na resposta dos coeficientes das sub-bandas de decomposição da transformada wavelet, capaz de melhorar a discriminação de eventos espícula e não-espícula. / Researchers have concentrated efforts in the past 20 years, by applying the wavelet transform in processing, filtering, pattern recognition and classification of biomedical signals, in particular signals of electroencephalogram (EEG) containing events characteristic of epilepsy, the spike. Several families of mother-wavelets were used, but there are no consensus about which mother-wavelet is the most adequate for this purpose. The signals used have a wide range of events. The literature reports EEG signals sampled from 100 to 600 Hz with spikes ranging from 20 to 200 ms. In this study we used 98 wavelets. The EEG signals were sampled from 200 Hz up to 1 kHz. A neurologist has scored a set of 494 spikes and a set 1500 non-spike events. This study starts evaluating the amount of wavelet decompositions required for the detection of spikes, followed by detailed analysis of the combined use of mother-wavelets of the same family and among families. Following is analyzed the influence of descriptors and the combined use of them in spike detection. The results of these studies indicate that it is more appropriate to use a set of mother-wavelets, with many levels of decomposition and with various descriptors, instead of using a single mother-wavelet or a specific descriptor for the detection of spikes. The selection of this set of wavelets, decomposition level and descriptors allows to obtain high levels of detection according to the computational load desired or computing platform available for implementation. This study reached performance levels between 0.9936 to 0.9999, depending on the computational load. Other contributions of this study refer to the analysis of the border extension methods for spike detection; and the influences of the EEG signal sampling rate in the classifier performance, each one with significant results. Also shown are: a new spike detection architecture by making use of linear discriminant analysis; and the presentation of a new descriptor, the centred energy, based on the response of the coefficients of decomposition levels of the wavelet transform, able to improve the discrimination of spike and non-spike events.
333

Desenvolvimento de um sistema para medir potência ativa em equipamentos eletrocirúrgicos em tempo real / System development for active power calculation in electrosurgical units

Dums, José Flávio 23 November 2017 (has links)
FUMDES/UNIEDU; FITEJ; / Este trabalho apresenta a concepção de estruturas eletrônicas que podem ser utilizadas para a leitura de tensão e de corrente em conversores estáticos de energia, chaveados ou não, que trabalham em frequências superiores a 100 kHz, em especial as frequências eletrocirúrgicas (300 kHz..5 MHz). Além das estruturas de leitura, também a potência instantânea e a potência ativa são determinadas de forma analógica, possibilitando o futuro desenvolvimento de um sistema de controle da potência ativa de saída de um equipamento eletrocirúrgico. O objetivo é apresentar uma estrutura cuja reatância seja desprezível na faixa de frequências considerada, ou cujo efeito possa ser compensado, possibilitando a criação de circuitos amostradores de sinais complexos, de alta frequência, com um baixo custo de implementação, e usar estas amostras para determinar a potência ativa entregue. Um breve estudo das características reais dos resistores axiais de sinal (resistores com corpo cilíndrico, revestido por um filme de carbono ou filme metálico e com fixação por terminais através de furos na placa de circuito impresso, do inglês Pin Through Hole - PTH), de superfície (Surface Mounted Device - SMD) e resistores de potência de fio também é apresentado. Em seguida, dois modelos simplificados, porém realísticos, são apresentados, sendo um para resistências inferiores a 100 Ohms (Ω) e outro para resistências superiores a 100 Ω. Na sequência, um sistema analógico que realiza a amostragem dos sinais de tensão e de corrente de saída é proposto, bem como um sistema que determina a potência ativa em tempo real. Cada sistema é desenvolvido e testado individualmente, sendo que os resultados validados de um estágio são utilizados para aferir a eficácia do estágio subsequente. Ao final, o conjunto é testado, por meio de uma sequência de ensaios, cujos resultados são analisados e as considerações acerca do sistema como um todo são apresentadas, enfatizando que o erro máximo no cálculo da potência ativa ficou abaixo de 20%, como exige a norma NBR IEC 60601-2-2, assim como o baixo custo de implementação foi alcançado. Por fim, estes resultados mostram uma maneira viável de implementar um sistema de medição de potência ativa para saídas de equipamentos eletrocirúrgicos. / This work presents the design of electronic structures that can be used for voltage and current probing in static power converters, switched or not, which work at frequencies above 100 kHz, in particular electrosurgical frequencies (300 kHz..5 MHz). In addition, also the instantaneous power and the active power are determined analogically, allowing the development of a control system that stabilizes active output power of an electrosurgical unit. The purpose of this work is to find a structure with neglectable reactance in the frequency band considered, or compensate them, creating low cost sampler circuits for complex high frequency signals. A brief study of Pin Through Holes (PTH) signal resistors, Surface Mounted Devices (SMD) signal resistor, and power wire resistors above 100 Ω characteristics is presented. Two realistic simplified models are proposed. One for signal resistances lower than 100 Ω and power wire resistors lower than 100 Ω. Another one for signal resistance greater than 100 Ω. Further, an analog system for reading the output voltage and current are proposed as well as one for real time active power determination. Each system is individually designed and tested. Validated results of one stage are used to assess the effectiveness of the subsequent stage. In the end, the full circuit is tested, and the results are analyzed demonstrating that a lower than 20% error is achieved as well as the low implementation cost. Finally, these results show a way to implement an active power measurement system for electrosurgical units that is unprecedented up to now.
334

Avaliação da interação de feixes monoenergéticos e polienergéticos por meio de simulações em GEANT4 em fantomas diversos / Evaluation of the interaction of monoenergy and polyenergytic beams by means of GEANT4 simulations in miscellaneous phanton

Yagui, Akemi 06 July 2017 (has links)
A terapia com prótons está presente em 16 países e até 2015 tratou mais de 130 mil pacientes. No entanto, no Brasil essa terapia ainda não está presente por diversos motivos, sendo o principal o alto custo. Antes de realizar tratamentos, é necessário fazer alguns testes para verificação da entrega de energia dos feixes de prótons. Como as medidas de microdosimetria são muito caras, a principal alternativa é a realização de simulações em programas computacionais, como o GEANT4 e SRIM. O GEANT4 é um programa que permite simular geometrias complexas, enquanto que o SRIM realiza simulações mais simples e ambas trabalham com o método de Monte Carlo. Neste trabalho foram utilizadas estas duas ferramentas para realizar simulações de feixes de prótons em fantomas com três diferentes composições (água, água e tecido ósseo, tecido ósseo e cerebral). Para realizar a análise da entrega de energia dos feixes de prótons ao longo destes fantomas, tornou-se necessário criar um programa denominada “Programa de Processamento de Dados em Próton Terapia Simulada”, que proporcionou criar matrizes, além dos cálculos dos picos de Bragg para avaliação da interação. Além disso, foi analisada a homogeneidade da interação de um feixe de prótons em um detector, em que foi verificado que as simulações em GEANT4 são homogêneas, não tendo uma tendência do feixe em se localizar em uma determinada região, assim como as energias depositadas são iguais nas regiões do fantoma. Também foram avaliados os valores do alcance de profundidade dos picos de Bragg em fantomas cilíndricos com três diferentes densidades: 1,03 g/cm³, 1,53 g/cm³ e 2,03 g/cm³, sendo a primeira, a densidade fornecida pelo GEANT4 para tecido cerebral. Foi verificado que as distâncias do alcance de profundidade dos picos de Bragg são iguais nestas três diferentes densidades. / Proton therapy is present in 16 countries and by 2015 has treated more than 130,000 Patients. However, in Brazil this therapy is not yet present for several reasons, Being the main the high cost. Before performing treatments, it is necessary to do some tests to verify the energy delivery of the proton bundles. As the Microdosimetry are very expensive, the main alternative is to carry out simulations in Programs such as GEANT4 and SRIM. GEANT4 is a program that Allows you to simulate complex geometries, while SRIM performs more complex simulations. Simple and both work with the Monte Carlo method. On this work were used these twain tools to perform a proton beam simulation in phantom with three different compositions (water, bones and water, brain and bones). To perform the energy delivery analysis of the proton beams along these phantoms, has become necessary create a program denominated “Data Processing Program Proton Therapy Simulated”, which allowed to create matrices, beyond the calculations of the Bragg peaks for interaction evaluation. Besides that, it was analyzing the homogeneity of the integration of a proton beam into a detector, in which it was verified that the simulations on GEANT4 are homogeneous, not having a tendency of the beam in locating in a certain region, just as the energies deposited are equal. The value of the depth range of the Bragg peaks were also evaluated in cylindrical phantoms with three different densities: 1,03 g/cm³, 1,53g/cm³ and 2,03 g/cm³, the first being the density provided by GEANT4 for brain tissue. It has been found that the depth range distances of the Bragg peaks are the same at these three different densities.
335

Proposta e avaliação de indicadores de desempenho para gestão estratégica de unidades laboratoriais de instituição superior de ensino e pesquisa que impactam sobre a saúde humana / Proposal and evaluation of performance indicators for strategic management of the laboratory units in the higher research and teaching institution that impacts on human health

Conti, Denise De 16 March 2017 (has links)
A gestão de laboratório tornou-se essencial em razão da preocupação com a saúde e com o meio ambiente. Conhecer todos os processos e atividades desenvolvidas nessas unidades e adotar bons indicadores para avaliar o desempenho, facilitam o controle interno do laboratório. O uso combinado dos indicadores com as ferramentas de gestão como Gestão da Qualidade Total, Redesenho de Processos, Normas ISO, Pensamento Lean e Gestão do Erro, poderão propiciar uma melhora significativa na eficiência. Esse trabalho de Engenharia Biomédica, com linha de pesquisa em Engenharia Clínica e Gestão, tem como objetivo selecionar e avaliar indicadores que facilitem o controle interno de laboratórios e provoquem seu uso pelos tomadores de decisão e todos da Engenharia Clínica. O controle interno permite detectar desvios e realizar correções no desempenho das rotinas, prestando assim um serviço com confiabilidade nos resultados das pesquisas e laudo de testes e exames. A metodologia constou em selecionar um conjunto de indicadores a partir das rotinas utilizadas em laboratório clínico, por dispor de maior experiência e publicações na área de gestão. Este conjunto de indicadores foi aplicado em dois perfis de laboratórios: em um estrato, laboratórios que influenciam diretamente a saúde e em outro estrato, laboratórios que, o resultado de suas pesquisas possa alterar o meio ambiente e, dessa forma, impactar indiretamente a saúde humana. Sustentado em trabalhos da literatura especializada de autores conceituados, selecionou-se 30 indicadores contemplando uma Avaliação Prévia e as categorias de Indicadores de Liderança, de Responsabilidade Pública, de Planejamento Estratégico, de Operacionalização Estratégica e dos Grupos de Usuários. Os indicadores buscaram explorar a rotina das atividades e o envolvimento dos participantes e usuários na gestão de laboratórios universitários de Odontologia, Nutrição e Farmacologia (laboratórios com influência direta sobre a saúde) e laboratórios universitários de Veterinária, Agronomia e Zootecnia (laboratórios com influência indireta sobre a saúde). Para cada Indicador foram delineadas três opções de respostas que permitisse analisar a existência da prática, da rotina, sua intensidade e a visão do participante quanto à administração da unidade laboratorial. Os resultados foram analisados comparativa e proporcionalmente em três abordagens. Na primeira análise, cada opção de resposta de cada indicador foi comparada entre todos os laboratórios. Na segunda análise, cada opção de resposta de cada indicador foi comparada entre os dois estratos. E na terceira análise, foi comparado o percentual de cada opção entre todas as respostas. Estabelecido o limite de tolerância, pode-se identificar: os indicadores que atendem a expectativa, a qual estrato pertence e em que proporção. Da mesma forma pode-se identificar os indicadores com maior comprometimento na gestão e de quantos participantes espera-se o não atendimento do indicador. Com a metodologia proposta foi possível visualizar a realidade da unidade laboratorial, verificar a flexibilidade em estabelecer o limite de aceitação por prioridades e perceber que com o uso das ferramentas de gestão é possível, com pequenas intervenções, esperar grandes resultados. / Laboratory management has become essential due to health and enviroment concerns. Knowing all the processes and activities developed at the units and adopting good indicators to evaluate the performance, facilitates the internal control of the laboratories. The use of the indicators combined with management tools such as Total Quality Management, Process Redesign, ISO Standards, Lean Thinking and Error Management may provide a significant improvement at the efficiency. This Biomedical Engineering work, with Clinical Engineering and Management lines of research, aims at selecting and evaluating indicators that facilitate the internal control of the laboratories and induces its use by the decision makers and everyone in the Clinical Engineering. The internal control allows the detection of misapplications and corrections in the routine performance, thus providing a reliable work in the research results, tests and exams reports. The methodology consisted in selecting a set of indicators from the routines used in clinical laboratories because there is greater experience and publications at the management area. This set of indicators was applied to two laboratory profiles: laboratories that influence health directly and laboratories whose results of researches could affect the enviroment and, this way, impact indirectly on human heatlh. Sustained by works of the specialized literature by credible authors, 30 indicators were selected contemplating a Previous Evaluation and the categories of Leading Indicators, Public Responsability, Strategic Planning, Strategic Operationalization and User Group. The indicators tried to explore the activities routine and the involvement of the participants and users in the management of the Odontology, Nutrition and Pharmacology university laboratories (with a direct influence over health) and Veterinary, Agronomy and Zootechny university laboratories (with an indirect influence over health). To each indicator it was outlined three options of answers that allowed the analyses of the existence of the routine practice, its intensity and the participants’ vision concerning the management of the laboratory unit. The results were analyzed comparatively and proportionally into three approaches. In the first analysis, each answer option of each indicator was compared among all laboratories. In the second analysis, each answer option of each indicator was compared between the two strata. In the third analysis it was compared the percentage of each strata between all the answers. Being established the tolerance limit, it can be identified: the indicators that meet the expectations, to which strata it belongs and in what proportion. The indicator with major commitment in management and from how many participants no care of the indicator is expected can also be identified. With the proposed methodology it was possible to visualize the reality of the laboratory unit, verify the flexibility of establishing the limit of priorities acceptance and realize that with the use of the management tools it is possible to expect great results with small interventions.
336

Avaliação tecnológica e clínica de protetores nasais empregados na ventilação não invasiva de recém-nascidos / Clinical and technological assessment of nasal protectors employed in non-invasive ventilation of newborns

Camillo, Débora de Fátima 26 August 2016 (has links)
A lesão nasal decorrente do uso da ventilação não invasiva (VNI) é um evento adverso cada vez mais comum nas unidades de terapia intensiva neonatais (UTIN) e apresenta consequências a curto e longo prazo. Esta lesão pode resultar em sequelas tanto de ordem estética quanto funcional, limitar o uso da VNI em RN que necessita desse suporte ventilatório, causar desconforto e septicemia; podendo aumentar, desta forma, o tempo de internamento na UTIN. Esta pesquisa tem por objetivo avaliar tecnológica e clinicamente os protetores nasais empregados na VNI de RN internados na UTIN. A metodologia consistiu primeiramente em levantar as possíveis causas da lesão nasal e avaliar os fatores de risco associados ao seu desenvolvimento. Em seguida, foi realizado um ensaio clínico randomizado para comparar os efeitos de três tipos de proteção nasal e das prongas novas e esterilizadas sobre a gravidade da lesão nasal. E por fim, foi realizada a caracterização térmica e estrutural dos protetores nasais após serem envelhecidas com temperatura e umidade no interior da incubadora neonatal. As principais causas da lesão foram relacionadas às características do material, a problemas no equipamento, a fatores assistenciais, neonatais e profissionais. Neste estudo, foram constatados como fatores de risco: a idade gestacional, a massa ao nascer, o tempo total de permanência na VNI, a reutilização deste suporte, o tempo da primeira utilização e da reutilização da VNI, bem como o tempo de internação na UTIN. Não foram observadas diferenças significativas na gravidade da lesão quando comparadas as três proteções estudadas, nem quando utilizadas prongas novas e esterilizadas. Quanto à análise dos materiais, foi constatado que a exposição à temperatura e à umidade alterou a percentagem de cristalinidade e a rugosidade das proteções nasais estudadas. / The nasal injury resulting from the use of non-invasive ventilation (NIV) is an adverse event increasingly common in the newborn intensive care unit (NICU) and shows the short and long term consequences. This lesion can result both aesthetic and functional sequelae, limit the use of NIV in newborns who need this ventilatory support, cause discomfort and septicemia, may thereby increase the length of stay in NICU. This research aims to evaluate technological and clinically nasal protectors used with NIV of newborns admitted to the NICU. The methodology consisted primarily in raising the possible causes of nasal injury and assess the risk factors associated with its development. Then, it was conducted a randomized clinical trial to compare the effects of three kind of nasal protector and new and sterilized prongs on the severity of nasal lesions. And finally, it was performed the thermal and structural characterization of nasal protection after being aged with temperature and humidity inside the neonatal incubator. The main causes of injury were related to characteristics of the material, equipment problems, assistive, neonatal and professional factors. In this study, it was found as risk factors: gestational age, weight at birth, the total time stay in the NIV, the reuse of this support, the time of first use and reuse of NIV and the length of stay in the NICU. They were not observed significant differences in lesion severity when compared the three protectors studied, nor when used new and sterilized prongs. The materials analysis indicated that exposure to temperature and humidity changed the percentage of crystallinity and the roughness of the nasal protections studied.
337

Galvanic vestibular stimulator for fMRI research / Estimulador galvânico vestibular para experimentos de fMRI

Rülander, Britta Angela 02 March 2016 (has links)
CAPES / This master thesis presents the further development of a galvanic vestibular stimulator for use in fMRI examinations developed in a previous thesis (MANCZAK, 2012). This thesis amends the GVS by circuits to measure feedback values and implements the stimulation circuit with digital components, such as a microcontroller and flyback integrated circuits. The microcontroller is used in order to control the current source and process the measured values. The communication between the PC, which allows user interaction through a graphical user interface, and the microcontroller is implemented through optical communication, which is defined by a communication protocol specification. The digital circuitry is designed to be placed within the MRI room, meeting the requirements imposed by strong magnetic fields and radio frequency pulses. The underlying hypothesis of the thesis is that the device can be placed within the MRI room without having a negative impact on the MRI image quality. Laboratory tests without the MRI confirmed the correct design of the galvanic vestibular stimulator.
338

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.
339

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.
340

Aplicação da baropodometria no desenvolvimento de um protocolo de avaliação motora em crianças nascidas pré-termo após a aquisição da marcha / Baropodometry application in developing a motor evaluation protocol in preterm infants born after the acquisition of march

Coldebella, Cristiane 31 August 2016 (has links)
O nascimento prematuro contribui significativamente para o aumento de morbidades associadas ao desenvolvimento motor, tornando fundamental o acompanhamento contínuo destas crianças. Desta forma, a avaliação baropodométrica, por consistir em um método quantitativo de controle postural pode trazer vantagens para o diagnóstico e acompanhamento do desenvolvimento motor de crianças. Este estudo teve por objetivo desenvolver um protocolo de avaliação motora através dos dados e índices baropodométricos em crianças nascidas pré-termo. Foi realizado um estudo descritivo, onde foram avaliadas 103 crianças entre 24 e 59 meses. Destas, 40 nascidas pré-termo e 63 crianças nascidas a termo. Durante a seleção da amostra, foi preenchida uma ficha de avaliação correspondente ao pré-termo grupo e um questionário com relatos dos pais no grupo a termo. Após, foram aferidos massa corporal e estatura, seguida da aplicação da Escala de Desenvolvimento Motor. Por fim, a baropodometria foi realizada na forma estática, em três repetições, os quais consistiram de 5 segundos de adaptação da criança dobre a placa e 30 segundos onde foram aferidos dados de análise estática: pressão plantar e área do centro de oscilação corporal. Após, as pressões plantares foram transformadas em índices, o índice ânteroposterior foi definido pelas pressões plantares anterior e posterior: IAP= 1-2*│0,6-P│; e o índice látero-lateral, por sua vez, foi definido pelas pressões plantares laterais direita e esquerda: ILL= 1-│LD-LE│. Após a avaliação os dados foram submetidos ao teste de normalidade das distribuições de Shapiro-Wilk, após verificada a distribuição não-normal, foi aplicado o teste de Mann-Whitney para verificar diferença entre os grupos, a associação entre os valores obtidos pelo baropodômetro, Escala do Desenvolvimento Motor, e as principais características e intercorrências do grupo pré-termo foi verificada através da correlação de Spearman. Foi observada diferença significativa nos valores de ILL (p=0,000) entre crianças nascidas a termo e crianças nascidas pré-termo, e que esta diferença possui correlação moderada com a idade gestacional (ρ=0,304), em relação ao centro de oscilação de pressão, crianças nascidas a termo apresentaram menor oscilação quando comparado a idade cronológica (ρ=-0,354), sendo que esta relação foi contrária em crianças nascidas pré-termo (ρ=0,336). Quando analisado somente o grupo pré-termo, foi verificado que o ILL apresentou correlação moderada e inversa com o tempo de internação (ρ=-0,353) e com o tempo de ventilação mecânica (ρ=-0,317) e a aérea do centro de oscilação de pressão apresentou correlação moderada e direta com o tempo de ventilação não invasiva (ρ=0,341). A massa ao nascer apresentou correlação moderada com o ILL (ρ=0,359) e também com a idade motora (ρ=0,323) e o quociente motor (ρ=0,341) e correlação forte com a IG (ρ=0,898) em contrapartida o peso atual apresentou correlação moderada com o quociente motor (ρ=0,310), e a IG (ρ=0,381) e correlação forte com a idade motora (ρ=0,555) e a idade cronológica (ρ=0,613). Houve diferença significativa em relação a idade de aquisição da marcha das crianças que precisaram de acompanhamento fisioterapêutico das que não precisaram (p=0,013). Um índice ILL menor em prematuros, pode estar relacionado ao tempo de internação e ventilação mecânica, além da massa ao nascer, já a maior aérea do centro de oscilação de pressão possui correlação com o tempo de ventilação não invasiva. Também pode-se perceber que a massa atual e a idade cronológica influenciaram mais no desenvolvimento motor que a massa ao nascer e a idade gestacional em crianças prematuras. / Preterm birth contributes significantly to the increase of morbidities associated with motor development, making essential the continuous monitoring of these children. Thus, baropodometry analysis by consisting of a quantitative method for postural control can be advantageous for the diagnosis and monitoring of engine development of children. This study aimed to develop a motor evaluation protocol through the data and baropodometric indexes in preterm infants. It was a descriptive study, which were evaluated 103 children between 24 and 59 months. Of these, 40 preterm and 63 term infants. During the sample selection was completed an evaluation form with data from medical records corresponding to the pre-term group and a questionnaire to parents on group term. After, body mass and height were measured, then the implementation of the Motor Development Scale. Finally, baropodometry was held in static form, with three replicates, which consisted of 5 seconds of child adjustment bend the plate and 30 seconds which were measured static analysis data: plantar pressure and pressure swing center area. After, the plantar pressures were transformed into indexes, the anteroposterior index was defined by the anterior and posterior plantar pressures: API = 1-2 * │0,6-P│; and side side index, in turn, defined by the right and left side planter pressure: SSI = 1- │RS-LS│. After evaluating, the data were submitted to normality test of Shapiro-Wilk distributions, being checked the non-normal distribution, the Mann-Whitney test was used to verify differences between groups, the association between the values obtained by baropodometry analysis, Motor Development Scale, and the main characteristics and complications of preterm group was verified by Spearman correlation. Significant difference in the values of SSI (p = 0.000) among term infants and infants born preterm were observed, and this difference has moderate correlation with gestational age (ρ = 0.304) compared to the pressure oscillation center , full-term babies showed less fluctuation compared to chronological age (ρ = -0.354), and this relationship was contrary in preterm children (ρ = 0.336).When only analyzed the preterm group, it was found that the SSI had moderate and inverse correlation with the length of stay (ρ = -0.353) and the duration of mechanical ventilation (ρ = -0.317) and the air oscillation center pressure showed moderate and direct correlation with noninvasive ventilation time (ρ = 0.341).The mass at birth showed moderate correlation with SSI (ρ = 0.359) and also with the motor age (ρ = 0.323) and the ratio engine (ρ = 0.341) and strong correlation with gestational age (ρ = 0.898) in contrast current weight showed moderate correlation with the motor quotient (ρ = 0.310) and gestational age(ρ = 0.381) and strong correlation with the motor age (ρ = 0.555) and chronological age (ρ = 0.613). There was significant difference in the age of acquisition of march of the children who needed physical therapy monitoring of those who did not needed (p = 0.013). A smaller SSI index in premature infants, may be related to hospitalization time and mechanical ventilation, in addition to mass at birth, already the largest air pressure oscillation center has correlation with noninvasive ventilation time.It may also be seen that the current mass and chronological age influenced more motor development than the mass at birth and gestational age in preterm children.

Page generated in 0.0591 seconds