• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Influência do acabamento e polimento de resina composta na resistência adesiva à dentina e no ângulo cavo-superficial em esmalte / The influence of finishing and polishing procedures on dentin bond strength of resin composite and at the interface enamel/restoration

Regalado, Diego Ferreira 17 August 2007 (has links)
O objetivo desse trabalho foi verificar a influência do procedimento de acabamento e polimento das restaurações de resina composta na resistência adesiva à dentina, através de testes de microtração, assim como, analisar em microscopia eletrônica de varredura a interface dente/restauração no nível do ângulo cavo-superficial. Terceiros molares humanos extraídos e hígidos foram utilizados nesse estudo, após aprovação pelo Comitê de Ética em Pesquisa da FOB-USP. Os dentes foram restaurados com sistema adesivo Solobond M (VOCO) e resina composta Grandio (VOCO) e distribuídos nos seguintes grupos: G1 (controle) - sem acabamento e polimento, G2 - acabamento e polimento imediato, G3 - sem acabamento e polimento e armazenado por sete dias e G4 - acabamento e polimento após sete diasem estufa a 37ºC. Palitos com dimensões de 1mm x 1mm foram obtidos e submetidos a uma força de tração em uma máquina de ensaios universal EMIC à velocidade de 0.5mm/min. Para a análise em microscopia eletrônica de varredura, 20 terceiros molares receberam quatro preparos cavitários com 1mm de diâmetro e 3mm de altura que foram restaurados com o mesmo sistema restaurador utilizado para os testes de resistência adesiva e distribuídos nos mesmos grupos descritos acima. Após a obtenção dos espécimes de cada grupo, os dentes foram metalizados e analisados na interface dente/restauração em microscopia eletrônica de varredura por três examinadores. As médias de resistência adesiva (MPa) e respectivos desvios-padrão foram: G1 - 23,05 (8,62); G2 - 17,34 (6,11); G3 - 21,64 (7,63) e G4 - 18,12 (6,51). Os valores de resistência adesiva submetidos à Anova a um critério e teste de Fisher permitiram concluir que o procedimento de acabamento e polimento das restaurações de resina composta diminuiu significativamente a resistência adesiva à dentina. O teste de Kruskal-Wallis aplicado aos escores obtidos da análise das fendas no ângulo cavo-superficial permitiu determinar que o acabamento e polimento da resina composta não interfere na formação de fendas. / The objective of this study was to verify the influence of finishing and polishing procedures on dentin bond strength of resin composite, and at the interface tooth/restoration using MEV. Recently extracted human third molars were utilized in this study, after approved by ethics and search committee at FOB-USP. The teeth were restored with Solobond M (VOCO) adhesive system and resin composite Grandio (VOCO) and randomized in the follow groups: G1 (control) - no polishing and finishing, G2 - immediate polishing and finishing procedures, G3 - no polishing and finishing and stored for seven days e G4 - polishing and finishing procedures after seven days under water at 37oC. Sticks 1mm x 1mm were obtained and the bonds were then stressed to failure by microtensile forces in a EMIC universal testing machine at a crosshead speed of 0.5 mm/min. Twenty human third molars were prepared with four cavities with 1mm diameter and 3mm height and restored with the same restoration system used for the microtensile tests and were distributed at the same groups and the interface tooth/restoration was analyzed in MEV by three examinators. The means of bond strength (MPa) and respective standard deviation were: G1 - 23.05 (8.62); G2 - 17.34 (6.11); G3 - 21.64 (7.63) e G4 - 18.12 (6.51). The data were analyzed by One-Way Anova and e Fisher´s test. It was possible to conclude that the finishing and polishing procedures of resin composite decrease significantly the bond strength to dentin of the composite restorations. The Kruskal- Wallis test aplicated to gap scores at the tooth/restoration interface allows to determinate that the finishing and polishing procedures of resin composite do not interfere in gap formation.
72

Resistência adesiva ao cisalhamento de reparos em porcelana condicionada com laser / Shear bond strenght of porcelain repairs etched with laser

Hamilton Pedrazzi 26 November 2007 (has links)
O objetivo foi avaliar in vitro a resistência ao cisalhamento de reparos em porcelana condicionada com laser e compará-la aos tradicionais métodos de reparo condicionados com ácido hidrofluorídrico e ácido fosfórico. Neste estudo, foram utilizados dois condicionadores químicos de porcelana (ácido hidrofluorídrico a 10% - Dentsply; ácido fosfórico a 37% - 3M ESPE), um agente silano (Rely X Silano - 3M ESPE), um sistema adesivo (Scotchbond Multi-uso - 3M ESPE), um compósito restaurador (Filtek Z250 - 3M ESPE), uma porcelana odontológica (Ceramco 3 - Dentsply) e um laser de alta potência em regime de femtosegundo (Ti:Safira - Libra- S, Coherent). Sessenta pastilhas em porcelana foram confeccionadas e incluídas e anéis de PVC com resina acrílica quimicamente ativada. As pastilhas de porcelana foram polidas com lixas abrasivas em ordem decrescente de abrasividade para o aplainamento da superfície. Foram formados 6 Grupos (n=10) assim divididos: G1 - condicionamento com laser com potência 760mW; G2 - condicionamento com laser com potência de 760mW e aplicação de ácido fosfórico a 37% por 15s; G3: condicionamento com laser com potência de 900mW; G4 - condicionamento com laser com potência de 900mW e aplicação de ácido fosfórico a 37% por 15s; G5 - aplicação de ácido fosfórico 37% por 15s (grupo controle) e G6 - aplicação de ácido fluorídrico a 10% por dois minutos. Após o condicionamento da porcelana, foi aplicado agente silano para todos os corpos de prova, seguido da aplicação do sistema adesivo e polimerização por 20s. Foram confeccionados corpos de prova de resina composta na superfície da porcelana com a inserção de camadas através de matriz bipartida e de maneira incremental (2 incrementos), com fotopolimerização de 20 segundos por incremento, utilizando aparelho fotopolimerizador (XL 3000, 3M Dental Products). Em seguida a matriz foi removida e os anéis de resina com os corpos-de-prova confeccionados removidos do porta matriz e submetidos à nova fotopolimerização por mais 20 segundos. Depois de confeccionados os corpos-deprova foram levados á máquina de termociclagem por 1000 ciclos de 30 segundos em cada banho com temperatura entre 5ºC e 55ºC. Após a termociclagem os corpos-de-prova foram submetidos ao ensaio de cisalhamento. Os resultados foram avaliados estatisticamente por análise de variância (ANOVA 1 fator de variação) e teste de Tuckey (alfa=0,05). As médias e desvio padrão foram: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (letras iguais demonstram não haver diferença entre grupos). / The aim of this study was to evaluate in vitro the shear bond strength of repairs in porcelain conditioned with laser and to compare it to the traditional repair methods conditioned with hydrofluoric acid and phosphoric acid. In this study, were used two conditioning porcelain (10% hydrofluoric acid - Dentsply; 37% phosphoric acid - 3M ESPE), a silane agent (Rely X Silano - 3M ESPE), an adhesive system (Scotchbond Multi-uso - 3M ESPE), a composite resin (Filtek Z250 - 3M ESPE), a porcelain (Ceramco 3 - Dentsply) and a laser of high potency in femtosecond (Ti:Safira Libra-S, Coherent). Sixty porcelain discs were made and embedded in PVC rings using a polymethyl methacrylate resin. All specimen were smoothed with abrasive sandpapers in decreasing order of abrasiveness for the leveling of the surface. Six Groups were formed (n=10) being divided: G1 - conditioning with laser with potency 760mW; G2 - conditioning with laser with potency of 760mW and application of 37% phosphoric acid for 15s; G3: conditioning with laser with potency of 900mW; G4 - conditioning with laser with potency of 900mW and application of 37% phosphoric acid for 15s; G5 - application of 37% phosphoric acid for 15s (group control) and G6 - application of 10% hydrofluoric acid for two minutes. After the conditioning of the porcelain, silane agent was applied for all of the specimens, following by the application of the adhesive system and photoactivation for 20s. Specimens of composed resin were made in the surface of the porcelain aided with a metal matrix and insert of incremental layers (2 increments) with photoactivation of 20 seconds for increment. The photoactivation was performed with a visible light unit (XL 3000, 3M Dental Products). Afterwards the metal matrix was removed and the specimens were submitted to the new photoactivation for more 20 seconds. The specimens were submitted a thermal cycling by 1000 cycles of 30 seconds in each bath with temperature between 5ºC and 55ºC. After the thermal cycling , specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance - ANOVA One Way and Tuckey test (alfa=0,05). The averages and standard deviation: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (same letters demonstrate there not to be difference among groups).
73

Resistência e elasticidade da madeira e de juntas coladas de Eucalyptus grandis W. Hill ex-Maiden e seus impactos na mecânica de vigas laminadas coladas / Strength and elasticity of wood and glued joints of Eucalyptus grandis W. Hill ex Maiden and their impacts on the mechanic of glued laminated beams

Luisa Julieth Parra Serrano 21 June 2013 (has links)
A presente pesquisa teve como objetivo geral a otimização dos parâmetros de colagem para a fabricação de madeira laminada colada de Eucalyptus grandis, enfatizado na interação madeira-adesivo. Foi avaliada a influência da rugosidade, pressão de colagem, tipo de adesivo e tempo de armazenamento da madeira após a preparação das superfícies a serem coladas. Essas variáveis que afetam a qualidade da adesão foram analisadas a partir da resistência apresentada pelas uniões submetidas ao esforço de cisalhamento. Para complementar a compreensão da mecânica das juntas coladas, efetuou-se a caracterização qualitativa da linha de cola mediante análises microscópicas e imagens de raios-X. Estudaram-se as correlações existentes entre os pares possíveis das variáveis massa específica, resistência ao cisalhamento, rugosidade, profundidade de penetração e porcentagem de falha na madeira. A resistência do plano de cola em situação crítica de cisalhamento foi avaliada também em ensaios de flexão de vigas laminadas coladas. A eficiência adesiva, que é a relação entre a resistência da madeira maciça e a resistência da madeira laminada colada, não variou significativamente entre adesivo, pressão de colagem e acabamento de superfície. A eficiência adesiva das juntas coladas de madeira de Eucalyptus grandis com adesivos Cascophen e Jowapur foi satisfatória por ter estado sempre no intervalo de 90,9 a 127,8%. Observaram-se correlações muito fracas entre a espessura da linha de cola e as variáveis massa específica, resistência ao cisalhamento, eficiência adesiva e porcentagem de falha na madeira. As vigas solidarizadas com o adesivo Jowapur apresentaram um baixo módulo de elasticidade quando comparado ao da madeira maciça, sem apresentar diferenças significativa na resistência à flexão. Os processos de fabricação adotados garantiram uma qualidade ótima às juntas coladas, inferida pela observação das falhas que ocorreram tanto nos ensaios de cisalhamento quanto nos ensaios de flexão, nos quais as rupturas se deram ao longo da madeira maciça sem afetar o plano de cola. / The objective of the present study was to optimize the parameters of glue to manufacture laminated wood of E. grandis, emphasized the interaction wood-adhesive. The influence of the roughness, bonding pressure, adhesive type and time of storage of the timber after preparing the surfaces to be bonded were evaluated. These variables that affect the quality of adherence were analyzed from the resistance presented by the joints subjected to shear stress. To complement the understanding of the mechanics of bonded joints, we performed a qualitative characterization of the glue line by microscopy and X-ray imaging. Were studied correlations between possible pairs of variables: density, shear strength, roughness, depth of penetration, percentage of wood failure. The resistance of the bonding surface in critical shear was also measured using bending tests of glued laminated beams. The adhesive efficiency, which is the ratio between the resistance of the wood and the glued laminated wood resistance, did not vary significantly between adhesive, pressure bonding and surface finish. The adhesive efficiency of the bonded joints of Eucalyptus grandis with Cascophen and Jowapur was satisfactory falling always in the range from 90.9 to 127.8%. Very weak correlations were observed between the variables glue line thickness, density, shear strength, adhesive efficiency and percentage of wood failure. The beams glued with the adhesive Jowapur showed a low modulus of elasticity compared to solid wood, without showing significant differences in flexural strength. The manufacturing processes adopted ensured the optimal quality of bonded joints. This was inferred by observing the failures that occurred in both shear tests as in bending tests. Ruptures occurred within the wood without affecting the bonding surface.
74

Resistência de união entre cimentos resinosos e zircônia / Bond strenght between resin cements and zirconia

Valdivia, Juan Rommel Medina 18 August 2011 (has links)
Este estudo avaliou a resistência de união de cimentos resinosos à zircônia tetragonal parcialmente estabilizada com ítrio (NobelProceraTM Zircônia) submetida a tratamentos superficiais mecânicos e químicos. Os cimentos utilizados foram o cimento resinoso auto-condicionante de polimerização química Multilink (Ivoclar Vivadent) associado ao Metal/Zirconia Primer (Ivoclar Vivadent) e o cimento resinoso auto-adesivo de polimerização química e dual RelyX U100 (3M-ESPE) associado ao adesivo Adper Single Bond Plus 2 (3M-ESPE). Utilizando 40 cilindros de zircônia (diâmetro de 3,5 mm) foram realizados 120 ensaios (n=40 para cada cimento). Para cada cimento os cilindros foram divididos em 4 grupos (n=10) em função do tratamento superficial avaliado: 1- sem tratamento; 2- agente de união (primer ou adesivo); 3- jateamento com oxido de alumínio 50µm; 4- associação do jateamento e o agente de união. A aplicação do cimento resinoso foi realizada utilizando uma matriz de teflon com orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Após a aplicação de cada cimento nas 4 condições de superficie, os espécimes foram armazenados em água deionizada a 37ºC durante 24h e submetidos ao teste de resistência ao cisalhamento. Os resultados foram analisados com ANOVA a dois critérios e teste de Tukey (p<0,05). Sem tratamento superficial o RelyX U100 químico (5,52 Mpa) e dual (6,53 Mpa) tiveram melhor comportamento que o cimento Multilink (0,76). A associação do jateamento e o agente de união melhorou os valores de resistência de união para o cimento Multilink (7,68 Mpa) e para o cimento RelyX U100 dual (10,26 Mpa), sendo este último superior a todos os outros grupos. A associação do Adper Single Bond Plus 2 e o RelyX U100 sem jateamento, deve ser evitado. / The aim of this study was to evaluate the shear bond strength of resin cements to the yttria stabilized tetragonal zirconia (NobelProceraTM Zirconia) subjected to mechanical and chemical surface treatments. The cements used were: a self-etching resin cement with chemical polymerization Multilink (Ivoclar - Vivadent) associated to the Metal / Zirconia Primer (Ivoclar - Vivadent) and self-adhesive resin cement with chemical and dual polymerization RelyX U100 (3M-ESPE) associated to the adhesive Single Bond Plus Adper 2 (3M-ESPE). Using 40 cylinders of zirconia (3.5 mm diameter) were performed 120 trials (n = 40 for each cement). For each cement, cylinders were divided into four groups (n = 10) based on the surface treatment rated: 1 - untreated, 2 - bonding agent (primer or adhesive) 3 air abrasion with 50µm aluminum oxide, 4 - combination of air abrasion and bonding agent. The application of resin cement was performed using a teflon matrix with a central hole 3.5 mm in diameter and 3.0 mm deep. After application of each cement in the four surface conditions, the specimens were stored in deionized water at 37 ° C for 24 hours and tested for shear bond strength. Results were analyzed with an ANOVA Two Criteria and Tukey\'s test (p <0.05). Without surface treatment, chemical RelyX U100 (5.52 MPa) and dual (6.53 MPa) had better behavior than Multilink Cement (0.76). The combination of air abrasion and bonding agent improved the bond strength values for Multilink (7.68 MPa) and for RelyX U100 dual (10.26 MPa), this one superior to all other groups. The association of Adper Single Bond 2 and RelyX U100 Plus without air abrasion, should be contraindicated.
75

Avaliação da influência do choque térmico na aderência dos revestimentos de argamassa. / Evaluation of thermal shock\'s influence on bonding of external mortar renderings.

Temoche Esquivel, Juan Francisco 30 June 2009 (has links)
Neste trabalho enfoca-se o efeito da variação térmica na degradação da aderência de revestimentos de argamassa. Dentre os diversos fatores que condicionam a aderência dos revestimentos de argamassa, destaca-se aqui o cenário crítico definido pela presença de macrodefeitos na interface revestimento-base e também pela intensidade com que ocorre a variação de temperatura, encontrando-se uma situação extrema quando da ocorrência do choque térmico. Assim, o objetivo desta pesquisa é avaliar, de maneira experimental, o efeito de sucessivos ciclos de choque térmico na resistência de aderência de revestimentos de argamassa, em duas situações limites de taxa de macro-defeitos no contato entre o revestimento e a base e para duas distintas argamassas. Para dar suporte ao trabalho experimental foi elaborado um modelo computacional paramétrico, utilizando modelagem com elementos finitos. Com ele foi possível obter a distribuição de temperaturas, bem como as deformações e tensões geradas no revestimento, variando-se a intensidade do contato revestimento-base e alterandose as características da argamassa de revestimento. A partir de então, definiram-se as variáveis de maior influência e a geometria dos corpos prova, bem como as condições de contorno a serem utilizadas no programa experimental. O programa experimental foi desenvolvido em duas etapas: uma etapa piloto e outra definitiva. Para sua realização foram desenvolvidos e construídos os equipamentos para execução e controle dos ensaios cíclicos de choque térmico. Finalmente, foram realizados ensaios de resistência de aderência do revestimento e avaliados os efeitos de cada uma das variáveis estudadas, empregando-se suporte estatístico. Pelos resultados pode-se comprovar que os macro-defeitos na interface revestimento-base provocam diminuição na resistência de aderência a qual é agravada quando da ocorrência de cíclicos choques térmicos, ocorrendo a situação mais crítica para os revestimentos com maior módulo de elasticidade. / The present study focus on thermal variation effects on mortar rendering bonding degradation. Among the variety of factors that condition the bonding of mortar renderings, a critic scenario can be defined by the existence of interface macro-flaws between mortar rendering and substrate, and by the thermal variation intensity in the extreme situation of thermal shock. This research aims to experimentally evaluate the effects of continuous thermal shock cycles on the bonding strength of mortar renderings in two macro-flaw rate extreme situations in the contact surface between mortar rendering and substrate for two types of mortar. A parametric model based on finite element analysis has been developed to support the experimental work, which allowed ascertaining temperature profile as well as stress and strain distribution in the mortar rendering by changing the macro-flaws rate and mortar rendering properties. As a result, one could define the variables with higher influence and test panel geometry, as well as the boundary conditions to be used in the experimental program. The experimental program has been performed first in pilot scale and then in a definite stage, which required designing and building of equipment for the execution and control of cyclic thermal shock laboratory tests. Furthermore, bond strength tests have been performed on the mortar rendering samples, and effects of variables have been analyzed by using statistical help. Results have shown that the existence of interfacial macro-flaws decreases bond strength values between mortar rendering and substrate, and this scenario worsens under thermal shock. Mortar renderings with higher Youngs modulus (E) are more affected.
76

Influência do posicionamento do espécime na resistência adesiva à dentina e na espessura da camada de sistemas adesivos / Influence of dentin surface inclination on bond strength and adhesive layer thickness

Pazinatto, Flavia Bittencourt 06 April 2006 (has links)
Investigou-se a influência da inclinação das paredes de dentina (paralela ou perpendicular à ação da gravidade) e da variação regional dos espécimes (terços cervical ou oclusal) na resistência adesiva e na espessura da camada de adesivo. Vinte e cinco molares humanos foram seccionados no sentido mésio-distal e paralelamente ao seu longo eixo, obtendo-se secções vestibulares e linguais, as quais foram lixadas produzindo-se superfícies planas de dentina. Sistemas adesivos (Adper Single Bond-SB e Prime & Bond 2.1- PB2.1) foram aplicados na dentina, ora paralelamente ora perpendicularmente à ação da gravidade, padronizando-se o volume de adesivo (3,5 µl por gota) através do uso de uma micropipeta e seguindo-se as instruções dos fabricantes. Os grupos de estudo foram: 1A (SB, paralelo), 1B (SB, perpendicular), 2A (PB2.1, paralelo) e 2B (PB2.1, perpendicular). Após 24h de armazenamento em água deionizada a 37°C, espécimes foram preparados na forma de palitos de dentina com área adesiva de 0,8 mm2, aproximadamente. Na seqüência, foi determinada a espessura do adesivo de cada espécime, em micrômetros (µm), sob microscopia óptica (200X de aumento) e auxílio do programa Image Pro-Plus 4.5. Posteriormente, os espécimes foram submetidos à microtração sob velocidade de 0,5 mm/min. Todos os espécimes fraturados foram examinados sob microscopia óptica (40X de aumento) para a determinação dos planos de fratura. Os dados coletados foram submetidos aos testes ANOVA a 1 e 2 critérios e SNK (? = 0,05). Para determinação da correlação entre resistência adesiva e espessura do adesivo foi utilizado o teste de Correlação de Pearson. Os valores médios (MPa±d.p.) de resistência adesiva dos grupos 2A (52,93±15,19) e 2B (52,27±16,54) foram superiores àqueles dos grupos 1A (39,09±12,90) e 1B (32,94±12,42), independente da inclinação das paredes de dentina dos mesmos. Não houve diferença nos valores de resistência adesiva à dentina, independente da variação regional do espécime. Os valores médios (µm±d.p.) de espessura da camada de adesivo dos grupos 1A (11,24±2,92) e 1B (18,11±7,31) foram superiores àqueles dos grupos 2A (4,20±1,81) e 2B (3,87±1,29) (p > 0,05). O grupo 1B promoveu os maiores valores de espessura de adesivo, seguido do grupo 1A. As espessuras do adesivo nos grupos 2A e 2B apresentaram-se similares entre si. Houve influência da variação regional do espécime na espessura de adesivo somente para o grupo 1B. Não houve correlação entre resistência adesiva e espessura de adesivos para ambos SB e PB2.1 (r = -0,224, p = 0,112 e r = 0,099, p = 0,491, respectivamente). Conclui-se que a influência da inclinação das paredes de dentina e da variação regional dos espécimes na espessura da camada de adesivo é material-dependente, porém não influem na resistência adesiva dos sistemas adesivos à dentina. / To determine the effect of the inclination of dentin surfaces (parallel or perpendicular to the force of gravity) and the regional variation of specimens (cervical or occlusal thirds) on the dentin bond strength and adhesive layer thickness. Twenty-five extracted human molars were sectioned in a mesio-distal direction to expose flat dentin. Standardized drop volumes of adhesive systems (Single Bond-SB and Prime & Bond 2.1-PB2.1) were applied to dentin according to manufacturers instructions. Teeth were randomly divided into the following groups: 1A (SB, parallel), 1B (SB, perpendicular), 2A (PB2.1, parallel) and 2B (PB2.1, perpendicular). Teeth were stored in 37°C distilled water for 24h and then serially sectioned to obtain sticks with cross-sectional area of approximately 0.8 mm2 for microtensile bond strength test (MTBS). The thickness of adhesive layer of the MTBS specimen was determined in a light microscope at 200X magnification. Forty-eight hours after adhesion procedures the specimens were subjected to MTBS at a crosshead speed of 0.5 mm/min. After testing, the fracture modes of each specimen were determined by examination under a 40X magnification. One and two-way ANOVA and Student- Newman-Keuls-SNK tests were performed do determine differences in MTBS and in adhesive layer thickness among groups. The correlation between MTBS and adhesive layer thickness was compared with Pearson Product Moment Correlation ('alfa' = 0.05). Mean values (MPa±s.d.) for bond strength were higher for groups 2A (52.93±15.19) and 2B (52.27±16.54) than for groups 1A (39.09±12.90) and 1B (32.94±12.42), regardless of the position of dentin surfaces. There was no difference in MTBS, despite the regional variation of specimens. The thickness of adhesive systems (µm±s.d.) was higher for groups 1A (11.24±2.92) and 1B (18.11±7.31) than those for groups 2A (4.20±1.81) and 2B (3.87±1.29). Group 1B provided the greater mean values of adhesive thickness followed by the Group 1A. Similar adhesive thicknesses were found for Groups 2A and 2B, but significantly lower than the other groups. There was a significant influence of the regional variation of specimens on the adhesive thickness of group 1B. No correlation was found between bond strength and adhesive layer thickness for both SB and PB 2.1 (r = -0.224, p = 0.112 and r = 0.099, p = 0.491, respectively). The inclination of dentin surface and the regional variation of specimens on the adhesive layer thickness are materialdependent. These variables do not influence the adhesive systems bond strength to dentin.
77

Efeito do uso de primers bioativos na interface dentina-adesivo / Effect of bioactive primers on dentin--adhesive interface

Sousa, Ana Beatriz Silva 29 July 2015 (has links)
A longevidade das restaurações com compósitos está diretamente relacionada ao sucesso do tratamento estético. A vida útil das restaurações pode ser influenciada por vários fatores como o material empregado, tempo de uso clínico e a degradação da matriz dentinária por metaloproteinases da matriz (MMPs), que podem afetar a integridade da interface adesiva, fazendo com que a união dentina-­adesivo seja comprometida. Assim, buscando melhores resultados na durabilidade das restaurações adesivas, o objetivo deste estudo foi avaliar o efeito de substâncias inibidoras de MMPs (soluções de clorexidina -­ CHX a 0,2% e doxiciclina a 3%) e agente de ligação cruzada (extrato de semente de uva -­ grape seed extract - GSE a 15%) na Resistência de União (RU) de restaurações de resina composta submetidas à ciclagem mecânica. Cavidades de Classe I foram preparadas na área central da superfície exposta de 48 molares humanos hígidos, posteriormente separados em 4 grupos (n=12) de acordo com o tratamento de superfície recebido após o condicionamento de ácido: Grupo I -­ Controle (Sistema Adesivo -­ Adper Single Bond Plus -­ 3M ESPE); Grupo II -­ CHX 0,2% + Sistema Adesivo; Grupo III -­ GSE 15% + Sistema Adesivo e Grupo IV -­ Doxiciclina 3% + Sistema Adesivo. Após os procedimentos restauradores (Filtek Supreme Ultra -­ 3M ESPE), as amostras foram armazenadas em água destilada durante 24 horas a 37°C e subdividas em dois subgrupos: A -­ Controle (armazenado em saliva artificial) e B -­ Submetido à ciclagem mecânica (Coil Cycler, Proto-­tech, forca de 50 N, frequência de 1,5 Hz em 1 x 106 ciclos de aplicação). Após ciclagem mecânica, os corpos de prova foram cortados em palitos (0,8 x 0,8 mm; n = 5 por dente) e submetidos ao teste de microtração (Bisco) a velocidade de 1 mm/min. A atividade colagenolítica da MMP-­2 sob a ação dos primers bioativos foi analisada utilizando o kit EnzChek Gelatinase/Colagenase Assay (D-­12054, Molecular Probes, Eugene, OR, EUA). A atividade gelatinolítica das MMPs-­2 e -­9 após incubação com os primers bioativos foi avaliada através de zimografia convencional. Os resultados obtidos das duas análises foram apresentados na forma de porcentagem de inibição. Zimografia in situ foi realizada utilizando gelatina de fluorescência conjugada (Kit EnzChek Gelatinase/Collagenase Assay) como substrato de MMPs e avaliada com aumento de 40x através de microscopia de fluorescência. Posteriormente, os fótons fluorescentes foram analisados em software (ImageJ). Obtidos os resultados, os dados foram submetidos à análise estatística (2way ANOVA, Tukey, p>0,05) e demonstraram que os primers bioativos não exerceram influência significante sobre a RU dentina-­adesivo, independente da ação da ciclagem mecânica. A atividade colagenolítica, segundo zimografia convencional, demonstrou que os primers bioativos foram capazes de inibir as MMPs, sendo a CHX menos eficiente. Na análise de zimografia in situ, os primers bioativos diminuíram a atividade das MMPs localizadas na interface adesiva, com aumento da atividade gelatinolítica do grupo Controle sendo maior quando submetidos à ciclagem mecânica, efeito não encontrados no grupos tratados com primers bioativos. Concluiu-­se que, apesar de não apresentarem efeitos sobre a RU da interface adesiva, os primers bioativos apresentam ação sobre a degradação da camada híbrida. / The durability of composite resin restorations is one of the main points related to the success in aesthetic treatments. The longevity of adhesive restorations can be affected by various factors such as the materials, the clinical time of use and the dentin matrix degradation mediated by matrix metalloproteinases (MMPs). MMPs can affect the adhesive interface, compromising the bonding between dentin and adhesive. Thus, searching for better results on longevity of adhesive restorations, the aim of this study was to evaluate the effect of MMPs inhibitors (chlorhexidine -­ CHX 0.2% and doxycycline 3% ) and crosslinking agent (grape seed extract -­ GSE 15%) on resin composite bond strength (BS) of restorations submitted to load cycling. Class I cavities were performed in the central area of the exposed surface of 48 sound human molars. Then, it was divided into 4 groups (n=12) according to the surface treatment received after the acid etching: Group I -­ Control (Adhesive System -­ Adper Single Bond Plus -­ 3M ESPE); Group II -­ CHX 0.2% + Adhesive System; Group III -­ Doxycycline 3% + Adhesive System e Group IV -­ GSE 15% + Adhesive System. After restorative procedures (Filtek Supreme Ultra -­ 3M ESPE), the samples were stored in distilled water for 24 hours at 37°C and then subdivided into two subgroups (n=6): A -­ Control (stored in artificial saliva) and B -­ Submitted to load cycling (Coil Cycler, Proto-­tech, 50 N, 1.5 Hz, 1 x 106 cycles). After load cycling, the specimens were cut into sticks (0.8 x 0.8 mm; n = 5 per teeth) and submitted to the microtensile test (Bisco) at 1 mm/min. The collagenolytic activity of MMP-­2 under action of bioactive primers was analyzed using EnzChek Gelatinase/Colagenase Assay Kit (D-­12054, Molecular Probes, Eugene, OR, EUA). The gelatinolytic activity of MMPs-­2 and -­9 after incubation with the bioactive primers was evaluated by gelatin zymography. The results of these two analyzes were presented by percentage of inhibition. In situ zymography was performed using fluorescence conjugated gelatin (EnzChek Gelatinase/Collagenase Assay Kit) as MMP substrate and evaluated using 40x magnification under fluorescence microscopy. Then the fluorescent photons were analyzed with an appropriate software (ImageJ). The results were subjected to statistical analysis (2-­way ANOVA, Tukey, p<0.05) and the bioactive primers showed no significant influence on the dentin-­adhesive BS, regardless the load cycling action. According to gelatin zymography, the collagenolytic activity demonstrated that the bioactive primers were able to inhibit MMPs activity and CHX was less efficient. In situ zymography analysis, showed that the bioactive primers decreased the activity of MMPs located in adhesive interface. The data also demonstrated increased gelatinolytic activity on Control group, being higher when submitted to load cycling, and which effect was not found in the groups treated with bioactive primers. It could be concluded that although the bioactive primers did not influenced the BS of adhesive interface, they demonstrated positive results on hybrid layer degradation.
78

"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.

Ramires-Romito, Ana Cláudia Durante 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers’ specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).
79

Influência do protocolo de secagem dos canais radiculares na resistência de união e selamento apical de obturações com cimentos com silicato de cálcio e com hidróxido de cálcio / Influence of drying protocols in the bond strength and apical sealing of teeth filled with calcium silicate and calcium hydroxide sealers

Paula, Adrianne Calixto Freire de 01 October 2014 (has links)
O propósito deste estudo foi avaliar a influência de protocolos de secagem do canal na resistência de união (RU) e no selamento apical (SA) de obturações com AH Plus, Sealapex e MTA Fillapex. Cento e cinquenta e seis raízes de caninos superiores foram submetidas à biomecânica com sistema Reciproc (R50) e distribuídas de acordo com o protocolo de secagem (PS): GI- cones de papel; GII- álcool isopropílico 70% + aspiração com pontas NaviTips; GIII- etanol 95% + cones de papel; GIV- EndoVac + cone de papel. Cada grupo foi dividido em subgrupos conforme o cimento obturador: A- AH Plus; B- Sealapex; C- MTA Fillapex. Utilizou-se para todos os espécimes técnica de obturação do cone único. As raízes de cada subgrupo foram destinadas à avaliação do SA (n=8) e RU (n=5), por meio do método de filtração de fluidos (FF) e push-out (PO), respectivamente. Para o PO as raízes foram seccionadas e um slice de cada terço submetido ao teste e à análise do tipo de falha. Os dados foram submetidos aos testes Anova two-way e three-way e Tukey por meio dos software SPSS 15.0 e SigmaStat 3.5 (&alpha;=5%). Os resultados da FF mostraram diferença significante entre os cimentos MTA e Sealapex (p<0,05). O SA não sofreu influência dos protocolos. Na RU não houve diferença entre os terços do canal (p>0,05), mas houve entre os cimentos (p<0,05), protocolos (p<0,05) e na interação cimentos/protocolos (p<0,05). O AH Plus (1,39±0,60) apresentou os maiores valores de RU em relação ao Sealapex (0,83±0,33) e MTA (0,76±0,34). Espécimes secos com álcool isopropílico proporcionaram aos cimentos testados maior resistência de união que quando secos com etanol (p=0,005) e EndoVac (p=0,002). Canais secos com etanol não influenciaram os cimentos. O uso de cones de papel, EndoVac e álcool isopropílico e obturação com AH Plus apresentaram os maiores valores RU que os demais cimentos. Concluiu-se que a infiltração ocorrida com o AH Plus foi semelhante a dos demais cimentos. O AH Plus apresentou os maiores valores de RU. No terço cervical houve predominância de falhas coesivas e de mistas nos demais terços. / The purpose of this study was to evaluate the influence of drying protocols in the bond strength (BS) and in the apical sealing (AS) of teeth filled with AH Plus, Sealapex and MTA Fillapex. One hundred and fifty-six roots of maxillary canines were subjected to biomechanical preparation with Reciproc (R50) and hand out according to the drying protocol (DP): GI-paper points; GII-70% isopropyl alcohol + aspiration with NaviTip points; GIII-95% ethanol + paper points; GIV-EndoVac + paper points. Each group was divided into subgroups according the used sealer: A- AH Plus; B- Sealapex; C- Fillapex MTA. The single cone obturation technique was used for all the samples. The roots of each subgroup were intended for the evaluation of the AS (n = 8) and the BS (n = 5) by using the fluid filtration (FF) and the push-out (PO) methods, respectively. Regarding the PO, the roots were sectioned and a single slice from each third was subjected to testing and also analysed for the type of failure. Data was submitted to the Tukey, two-way and the three-way variance analysis (ANOVA) resorting the SPSS 15.0 and the SigmaStat 3.5 (&alpha;= 5%) software. The results of the FF revealed a statistical significant difference between the MTA and the Sealapex (p <0.05) sealers. The AS showed no influence of the protocols. When it comes to the BS there was no statistical significant difference between the canal thirds (p> 0.05), but there was between the sealers (p <0.05), the protocols (p <0.05) and in the interaction between the sealers and the protocols (p <0.05). AH Plus (1.39 ± 0.60) revealed the highest BS comparing with Sealapex (0.83 ± 0.33) and MTA (0.76 ± 0.34). The specimens in which the isopropyl alcohol was used, had the highest bond strength results for the sealers, comparing with ethanol (p = 0.005) and EndoVac (p = 0.002). In the canals that ethanol was used, no alteration of the sealer was noticed. The use of paper points, EndoVac and isopropyl alcohol and filling with AH Plus revealed the highest BS values comparing with the other sealers. It was concluded that the infiltration that occurred with AH Plus was similar with the other sealers. AH Plus showed the highest BS. In the cervical third there was preponderance of cohesive failures, and in the other thirds the mixed type of failure.
80

Avaliação da resistência adesiva à dentina tratada pela terapia fotodinâmica em dente bovino / Evaluation of the bond strength to dentin treated by photodynamic therapy in bovine tooth

Bernal Rodriguez, Christian Giancarlo 17 January 2017 (has links)
A Terapia fotodinâmica (TF) é uma técnica que combina a ativação de um fotossensibilizador por luz na presença de oxigênio, produzindo radicais que induzem a morte celular dos microrganismos. Esta terapia vem sendo usada para reduzir a quantidade de microrganismos sendo um potencial antimicrobiano nos tecidos cariados em um processo restaurador direto, evitando assim o processo de cárie recidivante que pode acontecer quando não se promove a eliminação dos restos de microrganismo remanescentes após a utilização dos instrumentos rotatórios. O objetivo deste estudo in vitro foi avaliar a resistência de união de dois sistemas adesivos (condicionamento total e autocondicionante), sobre a superfície de dentina bovina, após tratamento com terapia fotodinâmica. Foi feito ensaio de microcisalhamento com o objetivo de avaliar a resistência de união. Para a realização da terapia fotodinâmica foi usado azul de metileno a 0,01% e duas fontes de luz diferentes, laser vermelho (660 nm) e LED (645-630 nm), com parâmetros já testados em estudos anteriores e, atualmente, utilizados na clinica odontológica. Para avaliar a resistência de união foi utilizado ensaio mecânico de microcisalhamento e, para isso, se utilizou sessenta discos de dentina, obtidos a partir de sessenta incisivos centrais bovino íntegros. Após o desgaste da dentina, as amostras foram dividas aleatoriamente em 6 grupos, sendo n=10 para o ensaio de microcisalhamento (G1: adesivo autocondicionante Single Bond Universal (USB) sem PDT, G2: PDT com laser + USB, G3: PDT com LED + USB; G4: adesivo de condicionamento total com Adper Single Bond 2 (ASB) sem PDT; G5: PDT com laser + ASB¸ G6: PDT com LED + ASB). Em cada amostra foram confeccionados 03 cilindros de resina composta, os quais foram submetidos à avaliação de microcisalhamento (1 mm/min); após armazenamento em saliva artificial por 24 horas. Após este teste, as amostras foram levadas em lupa estereoscópica (40x) para análise do padrão de fratura. Os resultados do teste de resistência de união foram tabulados e submetidos ao teste ANOVA dois fatores (adesivo e tratamento) e Tukey adotando-se um nível de significância de 5%. Quanto à resistência de união, não houve diferença significativa entre os 6 grupos analisados. Houve predominância de padrão de fratura do tipo adesiva. Com base nos resultados e nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que não existe alteração na força de adesão da resina na dentina hígida após tratamento com PDT. / Photodynamic Therapy (PDT) is a technique that combines the activation of a photosensitizer by light in the presence of oxygen, producing radicals that induce cell death of the microorganisms. This therapy has been used to reduce the amount of microorganisms being an antimicrobial potential in the decayed tissues in a direct restorative process, thus avoiding the process of recurrent caries that can happen when the elimination of remaining remains of microorganism after the use of the instruments is not promoted. The objective of this in vitro study was to evaluate the bond strength and morphology of the hybrid layer of two adhesive systems (Self-etch and total etch) on the bovine dentin surface, after treatment with photodynamic therapy. A micro-shear test was performed in order to evaluate the bond strength. To perform the photodynamic therapy, 0.01% methylene blue and two different light sources, red laser (660 nm) and LED (645-630 nm) were used, with parameters already tested in previous studies and currently used in the dental clinic. In order to evaluate the bond strength, a microshear bond strenght test was used. For this purpose, sixty dentin disks were obtained from sixty complete central incisors. After dentin wear, the samples were randomly divided into 6 groups, with n = 10 for the micro bond strenght test (G1: Self-etch adhesive, single bond Universal (USB) without PDT, G2: PDT with laser + USB, G3: PDT with LED + USB; G4: total etch adhesive Single Bond 2 (ASB) without PDT; G5: PDT with laser + ASB¸ G6: PDT with LED + ASB). In each sample, 03 cylinders of composite resin were made, which were submitted to the evaluation of micro-shear strenght test (1 mm / min); after storage in artificial saliva for 24 hours. After this test, the samples were taken in a stereoscopic magnifying glass (40x) for analysis of the fracture pattern. The results of the Microshear bond strength test were tabulated and submitted to ANOVA two-factor test (adhesive and treatment) and Tukey adopting a significance level of 5%. Regarding the bond strength, there was no significant difference between the 6 groups analyzed. There was a predominance of an adhesive type fracture pattern. Based on the results and the irradiation parameters used in this study, it can be concluded that there is no alteration in the adhesion strenght of the resin in a healthy dentin after treatment with PDT.

Page generated in 0.0526 seconds