• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 5
  • 4
  • 1
  • Tagged with
  • 93
  • 35
  • 20
  • 17
  • 17
  • 17
  • 15
  • 13
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Medições destrutivas e não-destrutivas em campos eletromagnéticos e processos não-estacionários em eletrodinâmica quântica de circuitos

Dodonov, Alexandre 10 February 2009 (has links)
Made available in DSpace on 2016-06-02T20:15:19Z (GMT). No. of bitstreams: 1 2229.pdf: 2727088 bytes, checksum: 4c71ca2bc9e58b1b9250df612f0d73d1 (MD5) Previous issue date: 2009-02-10 / Universidade Federal de Sao Carlos / (caracteres incompatíveis, vide PDF)
62

Resistência à fratura de dentes com preparos cavitários MOD restaurados com resina composta e fibra de vidro

Rodrigues, Fausto Borges January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000392253-0.pdf: 813004 bytes, checksum: 92cc239906e68f814913bc5491cecb54 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate in vitro the effect of two types of glass fibers, unidirectional or woven, placed inside of MOD cavity preparations on fracture strength of endodontically treated molars, either restored with composite resin, or not. Ninety sound human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to six groups (n=15). Group 1 G1 (sound teeth), control. Groups G2, G3, G4, G5 e G6 were subjected to the following procedures: G2 – MOD cavity preparation; G3 – MOD and endodontic treatment (ET); G4 –MOD + ET + composite resin restoration (CR); G5 – MOD + ET + unidirectional fiber (UF) + CR; G6 - MOD + ET + woven fiber (WF) + CR. The specimens were stored in physiological serum at 37oC for 24 hours. Later, a compressive force was applied by means of a universal testing machine at 1 mm/min speed, parallel to the long axis of the teeth until the fracture occurred. After mechanical test three types of fractures were classified: 1) pulp chamber floor; 2) cusp; 3) pulp chamber floor and cusp. The means of results (N) followed by the same letter do not represent a statistical difference by ANOVA and Tukey (p<0,05): G1 (4960)a, G2 (1926. 20)b, G3 (612. 84)c, G4(1813. 9)b, G5 (2024)b, G6 (1879)b. In the analysis of qualitative variables of G5 and G6, there was a tendency to fracture in the pulp chamber floor and cusp not benefic to restore the tooth integrity. It is possible conclude that inserting the unidirectional or woven glass fibers into MOD cavity preparations and restored with composite resin the fracture strength is similar to that obtained in molars filled with composite resin only. / A proposta deste estudo foi avaliar o efeito de dois tipos de fibras, uma trançada e outra unidirecional, inseridas no interior de cavidades MOD padronizadas na resistência à fratura de dentes molares tratados endodonticamente. Noventa dentes terceiros molares hígidos foram selecionados e montados em blocos acrílicos, sendo estes divididos em seis grupos de quinze (n=15). No grupo G1, os dentes mantiveram-se hígidos (controle). Os grupos G2, G3, G4, G5 e G6 receberam preparos cavitários MOD padronizados, sendo que nos grupos G3, G4, G5 e G6 foram realizados tratamentos endodônticos. Após o preparo dos dentes, estes foram restaurados com resina composta, no grupo G4, e no grupo G5 e G6 foram inseridas dois tipos de fibras, uma trançada e outra unidirecional, respectivamente. Após, os corpos de prova foram submetidos ao ensaio de resistência à fratura. Avaliou-se, também, qualitativamente as falhas classificando-as em fratura de cúspide, assoalho e cúspide mais assoalho, após o ensaio mecânico. Os resultados (N) obtidos foram (médias seguidas de mesma letra não apresentam diferença estatística para Anova e Tukey (p<0,05): Grupo G1 (4960)a, Grupo G2 (1926,20)b, Grupo G3 (612,84)c, Grupo G4 (1813,9)b, Grupo G5 (2024)b, Grupo G6 (1879)b. Conclui-se que a utilização de fibras trançadas ou unidirecionais no interior de cavidades MOD de dentes com tratamento endodôntico não melhora a resistência a compressão apresentando um padrão de fratura de assoalho mais cúspide não favorável à recuperação da peça dentária.
63

Localização de estados quânticos vibracionais em armadilhas iônicas / Localization of vibrational quantum states in ionic trap

Hugo Sanchez de Araujo 22 February 2016 (has links)
Durante a década de 90 diversos trabalhos surgiram com o objetivo de investigar a localização de estados quânticos. No contexto da eletrodinâmica quântica de cavidades é possível localizar estados não clássicos de um dado campo externo aplicado ao sistema, uma cavidade preenchida com um material não linear inicialmente preparada no estado de vácuo. Baseado em tal cenário, propomos uma técnica de localização de estados vibracionais de um íon armadilhado. Para isso, considera-se um íon armadilhado em um potencial confinante cujos graus de liberdade vibracionais e os níveis eletrônicos do íon são acoplados por meio de um laser. Uma vez gerada a interação, faz-se uso da técnica de engenharia de reservatórios a fim de obtermos uma equação mestra na qual haja uma dinâmica emissiva e absortiva, ambas artificiais, promovidas por liouvillianos engenheirados, obtidos utilizando o sistema auxiliar (níveis internos do íon). Decorre-se disso uma dinâmica efetiva, já que a emissão espontânea é sempre presente. Sob um certo regime de parâmetros, a competição entre os liouvillianos leva o sistema de interesse para um estado vibracional estacionário caracterizando a localização. A técnica apresentada é mais geral pois mesmo partindo-se de um estado de máxima mistura, a localização é atingida com alta fidelidade em relação ao estado vibracional almejado. O papel exercido pela engenharia de interações para o sucesso da localização é o principal fator motivador deste trabalho. / In the 90s several works arose in order to investigate the localization of quantum states. In the context of quantum electrodynamics of cavities, it is possible to find non-classical states of a given external field applied to the system employing, for instance, a cavity (initially prepared in the vacuum states) filled with a non-linear material. In such scenario, we propose a trapped ion vibrational state localization technique. Consider a trapped ion confined in a potential whose vibrational and electronic degrees of freedom are coupled through two laser fields. Once such interaction is generated, we make use of the reservoir engineering technique in order to obtain a master equation in which there is an artificial dynamics of emission and absorption promoted by engineerined liouvillians obtained by using an auxiliary system (internal ion levels) within an effective dynamics, since the spontaneous emission is always present. Under a certain set of parameters, competition among liouvillians takes the system of interest to a vibrational steady-state featuring localization. The presented technique is interesting because the steady-state is achieved with high fidelity with respect to the desired vibrational state even when starting with highly mixed states. The role presented by the engineered interactions is fundamental for a successful localization and it is the primary motivation of this work.
64

"Estudo da morfologia da interface de união em diferentes regiões de uma cavidade MOD" / A morphological study of the bonding interface in different areas of MOD cavities.

Sandra Kiss Moura 12 June 2003 (has links)
RESUMO Esmalte e dentina são substratos dentários simultaneamente presentes na maioria das cavidades preparadas para restaurações adesivas, mas não há estudos sobre a morfologia regional das interfaces de união em uma mesma cavidade. Adesivos autocondicionantes incorporam a smear layer na camada híbrida e, conseqüentemente, as bactérias que porventura estejam presentes nela. Recentemente surgiu um adesivo autocondicionante com propriedades antibacterianas, conferidas pela adição de MDPB ao primer, mas ainda há poucas pesquisas sobre a morfologia da interface de união produzida por este material. Este estudo teve por objetivo analisar a morfologia de interfaces de união em diferentes regiões de cavidades MOD, através de microscopia eletrônica de varredura - MEV, em casos com adesivos autocondicionantes com ou sem MDPB. Como controle, foram usados dois adesivos de frasco único, cuja morfologia está amplamente descrita na literatura. Foram preparadas dezesseis cavidades Classe II em terceiros molares humanos hígidos, que foram restauradas com Z250 e um dos seguintes sistemas adesivos, aplicados segundo instruções dos fabricantes: ABF, Clearfil SE Bond, Single Bond e Prime & Bond NT. Após vinte e quatro horas de armazenamento em água destilada a 37ºC, os dentes restaurados foram seccionados em três planos de corte e preparados para análise em MEV, segundo o protocolo descrito por Montes et al. (2001). Também foram preparadas réplicas dos espécimes em resina epóxica. A morfologia das interfaces de união apresentou diferenças dependendo da região observada e também do tipo de sistema adesivo. A presença de MDPB não alterou a morfologia da interface de união dos adesivos autocondicionantes. A morfologia das interfaces de união em esmalte revelou perfeita adaptação ao substrato para todos os produtos estudados. / ABSTRACT Enamel and dentin are dental substrates simultaneously present in most cavity preparations for bonded restorations. Yet, no study can be found regarding the regional morphology of bonding interfaces present in a same cavity. Self-etching adhesive systems incorporate the smear layer into the formed hybrid layer, and consequently bacteria that might be present. Recently a self-etching system with antibacterial properties provided by the addition of MDPB was introduced in the market, but there is still little research on the interfacial morphology obtained with this material. This study aimed at analyzing the interfacial morphology in different areas of MOD cavities prepared using adhesive systems either with or without MDPB, by means of Scanning Electron Microscopy – SEM. Two single bottle adhesive systems whose morphology is widely described in the literature were used as control groups. Sixteen class II cavities were cut in sound human molars and restores using Z250 resin composite and one of the following adhesive systems, applied strictly according to the manufacturers’ instructions: ABF, Clearfil SE Bond, Single Bond and Prime & Bond NT. After 24-hour storage in distilled water at 37ºC, the teeth were sectioned in three directions and prepared for SEM analysis according to the protocol described by Montes et al. (2001). Replicas were also obtained from each specimen using epoxy resin. The interfacial morphology showed differences depending on the observed area, and also on the adhesive system. The presence of MDPB did not alter the interfacial morphology of the bonded interfaces obtained with self-etching adhesive systems. Bonded interfaces in enamel revealed perfect adaptation for all studied materials.
65

Síntesis de zeolitas mediante agentes directores de estructura usando procesamiento de datos masivos (Big Data)

León Rubio, Santiago 06 November 2023 (has links)
Tesis por compendio / [ES] Las zeolitas son un material de aluminiosilicatos cristalinos microporosos extensivamente utilizados como catalizadores y tamices moleculares involucrados en procesos de separación. La mayoría de estos materiales son sintéticos, obtenidos en laboratorio mediante un proceso hidrotermal y barajando gran cantidad de variables como: relación sílice/agua, temperatura, tiempo, agitación y composición química. Cuando en la síntesis se introducen ciertas moléculas orgánicas, llamadas agentes directores de estructura, es más fácil entender y seleccionar moléculas específicas para dirigir la síntesis hacia una zeolita en particular. La situación ideal sería que cada agente director de estructura condujese la síntesis a una única zeolita, lo cual es poco probable que suceda, ya que, otros términos energéticos también juegan un papel importante, en particular el flúor y el aluminio. En esta tesis doctoral será acometido el estudio de estos tres factores: agente director de estructura, flúor y aluminio, además de su papel en la síntesis de zeolitas desde un enfoque químico-computacional. Proponiendo agentes directores de estructura más precisos para la síntesis de zeolitas, siendo sintetizadas de manera alternativa y/o más sostenible. / [CA] Les zeolites són un material d'aluminosilicats cristal·lins microporosos extensivament utilitzats com a catalitzadors i tamisos moleculars involucrats en processos de separació. La majoria d'aquests materials són sintètics, obtinguts en laboratori mitjançant un procés hidrotermal el qual presenta una gran quantitat de variables com: relació silici/aigua, temperatura, temps; agitació i composició química. Quan a la síntesi s'introdueixen unes certes molècules orgàniques, anomenades agents directors d'estructura, és més fàcil entendre i seleccionar molècules específiques per dirigir la síntesi cap a una zeolita en particular. La situació ideal seria que cada agent director d'estructura conduïra la síntesi a una única zeolita, la qual cosa és poc probable que succeïsca, ja que, altres termes energètics també juguen un paper important, en particular el fluor i l'alumini. En aquesta tesi doctoral es portarà a terme l'estudi d'aquests tres factors: agent director d'estructura, fluor i alumini, a més del seu paper en la síntesi de zeolites des d'un enfocament químic-computacional. Proposant agents directors d'estructura més precisos per a la síntesi de zeolites, sent sintetitzades de manera alternativa i/o més sostenible. / [EN] Zeolites are a microporous crystalline aluminosilicate material extensively used as catalysts and molecular sieves involved in separation processes. Most of these materials are synthetic, obtained in the laboratory by means of a hydrothermal process, and by shuffling a large number of variables such as silica/water ratio, temperature, time, agitation, and chemical composition. When certain organic molecules, called structure-directing agents, are introduced in the synthesis, it is easier to understand and select specific molecules to direct the synthesis towards a particular zeolite. The ideal situation would be for each structure-directing agent to drive the synthesis to a single zeolite, which is unlikely to happen, since, other energetic terms also play an important role, in particular fluorine and aluminum. In this doctoral thesis, the study of these three factors: structure directing agent, fluorine, and aluminum, and their role in zeolite synthesis will be undertaken from a chemical-computational approach. Proposing more precise structure-directing agents for the synthesis of zeolites, being synthesized in an alternative and/or more sustainable way. / León Rubio, S. (2023). Síntesis de zeolitas mediante agentes directores de estructura usando procesamiento de datos masivos (Big Data) [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/199280 / Compendio
66

Tomografia de estados quânticos via Stern-Gerlach óptico de cavidades cruzadas / Quantum state tomography via optical Stern-Gerlach of crossed cavities

Maximo, Carlos Eduardo 22 July 2013 (has links)
No presente trabalho, buscou-se generalizar o Stern-Gerlach óptico para o caso de duas cavidades, as quais possuem eixos ópticos perpendiculares entre si. Nesse experimento, um pacote atomico de dois níveis incide em uma pequena fração do volume ocupado por dois modos, na região onde os nodos das ondas estacionárias de cada modo se superpõem. Diferentemente do Stern-Gerlach óptico de cavidade única, além do intercâmbio de fótons efetuado entre o átomo e cada modo separadamente, também ocorre interação modo-modo, mediada indiretamente pelo átomo. Esse fator contribui efetivamente na caracterização da distribuição de momento do átomo. Espera-se que os desvios de trajetória sofridos pelo átomo, decorrentes de sua interação simultânea com dois modos idênticos do campo de radiação, devam ser observados no plano definido pelas duas cavidades. O estudo é efetuado considerando-se o tratamento clássico da posição do centro de massa atômico, que está associado à sua direção de incidência. Além do que, considera-se a aproximação de Raman-Nath, na qual despreza-se a variação da energia cinética transversal ao movimento atômico, durante a interação átomo-modos. Verifica-se que a análise da distribuição de momento atômico transversal permite acessar a estatística de fótons dos modos das cavidades. Este resultado viabiliza a realização da tomografia dos estados de dois modos por meio da medida da distribuição de momento bidimensional dos átomos. Por fim, através da utilização de estados coerentes na configuração de cavidades cruzadas, investiga-se as possibilidades do controle da direção de deflexão do átomo para aplicações em litografia puramente quântica. / This work deals with the generalization of the optical Stern-Gerlach effect for two cavities whose optical axes are perpendicular to each other. An atomic wave of a two-level atom is focused on a small fraction of the volume occupied by the two modes, in the region where the standing waves nodes overlap. Unlike the optical Stern-Gerlach of single cavity, besides the separate photon exchange between an atom and each mode, there also occurs mode-mode interaction indirectly mediated by the atom. This fact contributes towards the characterization of the atomic momentum distribution. Trajectory deviations suffered by the atom due to its simultaneous interaction with the two identical modes of the radiation field are expected in the plane defined by the two cavities. The study is carried out considering the classical treatment of the atomic center of mass position, which is associated with its incidence direction. The Raman-Nath approximation, which neglects the variation in the kinetic energy transversal to the atomic motion during the interaction atom-modes is considered. The analysis of the transversal momentum distribution of the atom allows accessing the photon statistics of the cavities modes. This result enables the realization of the two-mode states tomography via measurement of the two-dimensional momentum distribution of the atom. Finally, by using coherent states of the crossed cavities configuration, the study investigates the possibilities of controlling the atomic deflection direction for applications to quantum lithography.
67

Estudo clínico randomizado de restaurações classe II de ART com e sem retenções proximais em dentes decíduos / Randomized clinical trial of multiple surface ART restorations with and without proximal retentions in primary teeth

Gonçalves, Priscilla Santana Pinto 14 June 2017 (has links)
O tratamento restaurador atraumático constitui-se numa abordagem de cuidados minimamente invasivos que objetivam a prevenção e interrupção da progressão da cárie dentária. Não existe na literatura estudo clínico randomizado em dentes decíduos comparando restaurações de classe II de ART, com e sem retenções adicionais. O objetivo deste trabalho foi avaliar o efeito de sulcos de retenção proximal sobre as taxas de sobrevida das restaurações classe II de ART em dentes decíduos, usando cimento de ionômero de vidro de alta viscosidade e alta resistência flexural. Foram incluídas 183 crianças com idade entre 4 a 7 anos, com boa saúde geral, 1 a 4 cavidades de classe II em molares decíduos sem envolvimento pulpar ou dor de dente. Dessas crianças, 300 dentes foram randomizados e distribuídos em dois grupos, conforme o índice de cárie da criança e o tamanho da cavidade a ser restaurada. Os grupos foram: controle restaurações de ART classe II convencionais (Grupo 1, n=150) e teste restaurações de ART classe II contendo sulcos de retenção proximais (Grupo 2, n=150). Cada um dos grupos seguiu procedimentos clínicos padronizados. No grupo teste as retenções foram realizadas com colher de dentina modificada no ângulo gengivovestibular/ lingual até 0,5 mm da junção amelo-dentinária da margem oclusal. Após 6 e 12 meses 130 restaurações do Grupo 1 e 110 restaurações do Grupo 2 foram examinadas de forma cega utilizando os critérios do ART Frencken adaptado e do USPHS modificado. Para a taxa de sobrevida das restaurações foi utilizado o teste de Kaplan-Meier (p<0,05). Não houve diferença significativa entre os grupos (p=0,70) utilizando os critérios do ART, sendo que as taxas de sobrevida encontradas para ambos os grupos foram superiores a 90%. O mesmo resultado foi observado em todos os critérios (cor, descoloração marginal, recidiva de cárie, forma anatômica, integridade marginal e textura superficial) USPHS (p>0,05). Os principais motivos de falhas das restaurações foram perda total ou parcial da restauração (84%), seguido de inflamação pulpar (16%). Conclui-se que as restaurações classe II de ART com sulcos de retenção proximal apresentaram taxa de sobrevida semelhantes às restaurações sem retenção após 6 e 12 meses. / The atraumatic restorative treatment is an approach of minimally invasive care that aims to prevent and interrupt the progression of dental caries. There is no randomized clinical trial in primary teeth with multiple surface ART restorations, with and without additional retentions. The aim of this study was to evaluate the effect of proximal retention grooves on the survival rates of occlusoproximal ART restorations in primary teeth using high viscosity glass ionomer cement with high flexural strength. A total of 183 children aged 4 to 7 years, with good general health, 1 to 4 occlusoproximal cavities in primary molars without pulp involvement or tooth pain were included. Of these children, three hundred teeth were randomized and alocated into two groups, according to the child\'s caries index and the size of the cavity to be restored. The groups were: control - conventional occlusoproximal ART restorations (Group 1, n=150) and test - occlusoproximal ART restorations containing proximal retention grooves (Group 2, n=150). The procedures of both groups followed standardized steps. In the test group the retentions were performed with a modified dentin spoon at the gingival-vestibular / lingual angle up to 0.5 mm from the amelodentin junction of the occlusal margin. After 6 and 12 months 130 restorations in Group 1 and 110 restorations in Group 2 were examined (blind) using the modified ART Frencken criteria and the modified USPHS criteria. The Kaplan-Meier test was performed for the survival rate of the restorations (p<0.05). There was no significant difference between groups (p=0.70) using the ART criteria, and the survival rates found for both groups were greater than 90%. The same results was observed for all USPHS criteria (color, marginal discoloration, secondary decay, anatomical form, marginal integrity and surface texture) (p>0.05). The main reasons for restorations failure were total or partial loss of restoration (84%), followed by pulpal inflammation (16%). It was concluded that multiple surface ART restorations with proximal retention grooves presented similar survival rates to non-grooves restorations after 6 and 12 months.
68

[en] CAVITY BACKED SLOT ANTENNAS: A FINITE ELEMENT-BOUNDARY INTEGRAL FORMULATION / [pt] ANTENAS TIPO FENDA EM CAVIDADES: ANÁLISE PELO MÉTODO DOS ELEMENTOS FINITOS - INTEGRAL DE FRONTEIRA

ANA CRISTINA DOS SANTOS DA SILVA PORTO 12 August 2004 (has links)
[pt] Devido às propriedades de banda larga e polarização circular, as antenas espirais tornaram-se bastante atrativas para diversos serviços de telecomunicações modernos e móveis. Neste trabalho uma antena espiral tipo fenda apoiada em uma cavidade cilíndrica metálica foi analisada. Por causa de sua geometria complexa, optou-se por um método numérico híbrido, realizado através de uma implementação de elementos mistos do método dos elementos finitos - integral de fronteira. Baseado nesta formulação, um programa computacional foi desenvolvido. Um grande esforço foi realizado a fim de escrever o programa de maneira que o armazenamento e as necessidades computacionais fossem mínimos, boa parte conseguida pela aplicação das condições de contorno na superfície metálica. Com o objetivo de melhor explorar a geometria do problema, definiu-se uma malha de elementos finitos onde a parte que cabia a abertura foi dividida em quadriláteros enquanto que no restante da superfície, elementos triangulares foram utilizados. Repetiu-se então esta malha ao longo da altura da cavidade, de maneira que hexaedros e prismas formaram a malha final. Para cada espécie de elemento, funções de base vetoriais específicas foram aplicadas. A fim de verificar a precisão do algoritmo, o mesmo programa computacional foi utilizado na análise de uma antena tipo fenda retangular, também apoiada em uma cavidade cilíndrica metálica. / [en] Known for the properties of broadband and circular polarization, spiral antennas have become sufficiently attractive for services of modern and mobile telecommunications. In this work a cavity-backed slot spiral antenna was analyzed. Because of its complex geometry, it was chosen a hybrid numerical method, carried through an implementation of mixing elements of the finite elements - boundary integral method. Based in this formulation, a computer program was developed. A great effort was carried out in order to write the program thus the computational storage and necessities were minimum, good part obtained by application of the boundary conditions on the metallic surface. With the goal of better exploring the geometry of the problem, a mesh of finite elements was defined where the part that fit the aperture was divided into quadrilaterals, while that in the rest of the surface, triangular elements were used. By repeating this mesh along the height of the cavity, hexahedrals and prisms formed the final mesh. For each kind of element, specific vector base functions were applied. In order to verify the accuracy of the algorithm, the same computational program was used in the analysis of a cavity-backed slot rectangular antenna.
69

Estudo do fenômeno de formação e colapso de macro cavidades em líquidos / Study of the phenomenon of formation and collapse of macro cavities in liquids

Pereira, Pedro Augusto Fernandes 02 April 2014 (has links)
A cavitação e a dinâmica de bolhas são tópicos bastante recorrentes na literatura, devido sobretudo a seus efeitos em diversos tipos de fenômenos, como transferência de calor e escoamento em tubos. Considerando fases líquidas, sabe-se que estas estruturas de cavidade estão normalmente associadas ao equilíbrio metaestável, alcançado devido a quedas locais de pressão ou ao superaquecimento de uma substância pura (ou quase). Nestes casos é necessária a inicialização da mudança de fase através de algum mecanismo adequado, o qual gera uma sequência rápida de fenômenos. Apesar de comumente associado a danos, recentemente vários estudos vêm mostrando aplicações práticas deste tema, além de um campo ainda pouco explorado, que é o das macro cavidades. Essas cavidades podem ser geradas através do aquecimento de água a baixa pressão, sob condições específicas, criando sequências explosivas e formando movimentos como pistão para a água no interior de um invólucro convenientemente dimensionado. Este fenômeno mostra-se semelhante em diversos aspectos às micro cavidades, mais especificamente às cavidades próximas a superfícies livres, embora, sem dúvida, em escala muito maior. Os aspectos mencionados foram filmados com câmeras de alta velocidade e as características observadas foram comparadas com aquelas observadas em micro escala. Vários testes foram desenvolvidos de forma a melhor entender a dinâmica da formação e colapso dessas estruturas, sobretudo levando em conta um comportamento mais unidimensional para a evolução da bolha. Através de várias aproximações e análise de diferentes hipóteses para a variação de pressão e para a força de resistência, soluções analíticas e numéricas foram obtidas para a força exercida no fundo do contêiner e para a expansão e colapso das bolhas ao longo do tempo. As soluções propostas, em comparação com os dados experimentais, mostraram boa concordância entre si, sugerindo que os aspectos fundamentais da dinâmica da cavidade foram devidamente considerados e quantificados. / Cavitation and bubble dynamics are fairly recurring topics in literature, mostly due to their effects in various types of phenomena such as heat transfer and flow in pipes. Considering liquid phases, it is known that these cavity structures are normally associated with the metastable equilibrium, reached due to local pressure drop or overheating of a pure substance (or nearly so). In these cases, the phase change require a startup via some appropriate mechanism, which generates a fast sequence of phenomena. Although commonly associated with damage, recently several studies shown practical applications of these topics, and a still little explored field emerged, which is the field of macro cavities. These cavities can be generated by heating water at a low pressure, under specific conditions, creating an explosive sequences and forming piston like movements for the water inside a properly scaled casing. This phenomenon appears to be similar in many aspects to micro cavities, more specifically for cavities near free surfaces, although, without doubt, on a much larger scale. The mentioned aspects were filmed with high-speed cameras and the main features were compared with those observed in micro scale. Several tests have been developed to better understand the dynamics of the formation and collapse of these structures, especially taking into account a more one-dimensional behavior to the evolution of the bubble. Through various approximations, and analysis of different assumptions for the variation of pressure and the resistance force, analytical and numerical solutions were obtained for the force exerted on the bottom of the container and the expansion and collapse of bubbles over time. The proposed solutions in comparison with experimental data showed good agreement between each other suggesting that the fundamental aspects of the dynamics of the cavity were properly considered and quantified.
70

Tomografia de estados quânticos via Stern-Gerlach óptico de cavidades cruzadas / Quantum state tomography via optical Stern-Gerlach of crossed cavities

Carlos Eduardo Maximo 22 July 2013 (has links)
No presente trabalho, buscou-se generalizar o Stern-Gerlach óptico para o caso de duas cavidades, as quais possuem eixos ópticos perpendiculares entre si. Nesse experimento, um pacote atomico de dois níveis incide em uma pequena fração do volume ocupado por dois modos, na região onde os nodos das ondas estacionárias de cada modo se superpõem. Diferentemente do Stern-Gerlach óptico de cavidade única, além do intercâmbio de fótons efetuado entre o átomo e cada modo separadamente, também ocorre interação modo-modo, mediada indiretamente pelo átomo. Esse fator contribui efetivamente na caracterização da distribuição de momento do átomo. Espera-se que os desvios de trajetória sofridos pelo átomo, decorrentes de sua interação simultânea com dois modos idênticos do campo de radiação, devam ser observados no plano definido pelas duas cavidades. O estudo é efetuado considerando-se o tratamento clássico da posição do centro de massa atômico, que está associado à sua direção de incidência. Além do que, considera-se a aproximação de Raman-Nath, na qual despreza-se a variação da energia cinética transversal ao movimento atômico, durante a interação átomo-modos. Verifica-se que a análise da distribuição de momento atômico transversal permite acessar a estatística de fótons dos modos das cavidades. Este resultado viabiliza a realização da tomografia dos estados de dois modos por meio da medida da distribuição de momento bidimensional dos átomos. Por fim, através da utilização de estados coerentes na configuração de cavidades cruzadas, investiga-se as possibilidades do controle da direção de deflexão do átomo para aplicações em litografia puramente quântica. / This work deals with the generalization of the optical Stern-Gerlach effect for two cavities whose optical axes are perpendicular to each other. An atomic wave of a two-level atom is focused on a small fraction of the volume occupied by the two modes, in the region where the standing waves nodes overlap. Unlike the optical Stern-Gerlach of single cavity, besides the separate photon exchange between an atom and each mode, there also occurs mode-mode interaction indirectly mediated by the atom. This fact contributes towards the characterization of the atomic momentum distribution. Trajectory deviations suffered by the atom due to its simultaneous interaction with the two identical modes of the radiation field are expected in the plane defined by the two cavities. The study is carried out considering the classical treatment of the atomic center of mass position, which is associated with its incidence direction. The Raman-Nath approximation, which neglects the variation in the kinetic energy transversal to the atomic motion during the interaction atom-modes is considered. The analysis of the transversal momentum distribution of the atom allows accessing the photon statistics of the cavities modes. This result enables the realization of the two-mode states tomography via measurement of the two-dimensional momentum distribution of the atom. Finally, by using coherent states of the crossed cavities configuration, the study investigates the possibilities of controlling the atomic deflection direction for applications to quantum lithography.

Page generated in 0.0775 seconds