• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 2
  • Tagged with
  • 72
  • 33
  • 27
  • 27
  • 23
  • 23
  • 22
  • 21
  • 15
  • 15
  • 13
  • 12
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Transporte de cloretos em concretos com adições minerais e o desempenho em relação à corrosão das armaduras / Transport of chlorides in concretes with mineral additions and corrosion performance of reinforcement

Martins, Alex Mizael 16 December 2016 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-10-18T11:59:04Z No. of bitstreams: 2 Dissertação - Alex Mizael Martins - 2016.pdf: 6652239 bytes, checksum: 06fc65f07d3460875f7ecd163b128a49 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-10-18T12:00:09Z (GMT) No. of bitstreams: 2 Dissertação - Alex Mizael Martins - 2016.pdf: 6652239 bytes, checksum: 06fc65f07d3460875f7ecd163b128a49 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-10-18T12:00:09Z (GMT). No. of bitstreams: 2 Dissertação - Alex Mizael Martins - 2016.pdf: 6652239 bytes, checksum: 06fc65f07d3460875f7ecd163b128a49 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-12-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The introduction of wind energy into the brazilian energy matrix is of paramount importance for national energy policy. In this context, the viability of wind towers is a fundamental issue. In Brazil, these towers are built mainly in reinforced concrete, in regions of high aggressiveness (coastal regions, because of their greater wind potential) and, therefore, it is necessary to develop high performance concretes that are able to withstand environmental actions to which they are subjected, mainly the action of the chlorides, so that these structures reach the previously defined project life, thus guaranteeing the viability of the towers. In this sense, the present work evaluates the mechanical properties, the mechanisms of transport of chlorides and the performance in relation to the corrosion of the reinforcement, in concretes that contain high performance pozolanic mineral additions, in order to evaluate the influence of the presence of these additions in these properties. Three different study mixes were developed containing respectively, 9% of silica fume in composition with 1% of nanosilica, 5% of a high fineness metakaolin in composition with 5% of a slightly less fine metakaolin, both with high pozzolanic activity and a mix containing only 10% of the finest metakaolin, in addition to a reference mix. Analyzes related to the chloride transport are presented: penetrability and diffusion; analyzes related to the corrosion of reinforcement: induction of corrosion by aggressive solution wetting cycles and air drying, surface electrical resistivity of concrete and corrosion potential, besides the mechanical characterization. The concretes with incorporation of pozzolanic addition showed, in general, improvements in the mechanical properties. In the chloride transport properties and corrosion performance of the reinforcements, the improvements from the mineral additions were significant. Thus, it was concluded that the incorporation of the different mineral additions studied in the present work significantly altered the properties of the concrete, with a positive highlight for the properties associated with durability, in which the benefits of using mineral addition are more pronounced. / A introdução da energia eólica na matriz energética brasileira é de suma importância para a política energética nacional. Nesse contexto, a viabilidade das torres eólicas é questão fundamental. No Brasil essas torres são construídas, principalmente, em concreto armado em regiões de alta agressividade (regiões litorâneas, por terem maior potencial eólico) e, portanto, faz-se necessário o desenvolvimento de concretos de alto desempenho que sejam capazes de resistir às ações ambientais às quais são submetidos, principalmente à ação dos cloretos, de maneira que essasestruturas atinjam a vida útil de projeto previamente definida, garantindo assim a viabilidade das torres. Nesse sentido, o presente trabalho avalia as propriedades mecânicas, os mecanismos de transporte de cloretos e o desempenho em relação à corrosão das armaduras, de concretos que contêm adições minerais pozolânicas de alto desempenho, a fim de avaliar a influência dessas adições nessas propriedades. Foram elaborados três diferentes proporcionamentos de estudo contendo respectivamente, 9% de sílica ativa em composição com 1% de nanossílica, 5% de um metacaulim de elevada finura em composição com 5% de um metacaulim um pouco menos fino, ambos de elevada pozolanicidade e um proporcionamento contendo exclusivamente 10% do metacaulim de maior finura, além de um proporcionamento de referência. São apresentadas análises relacionadas ao transporte de cloretos: penetrabilidade e difusão; análises relacionadas à corrosão das armaduras: indução da corrosão por meio de ciclos de molhagem em solução agressiva contendo cloretos, medidas de resistividade elétrica superficial do concreto e potencial de corrosão, além da caracterização mecânica. Os concretos com incorporação de adição pozolânica apresentaram, em geral, melhorias em suas propriedades mecânicas. Já nas propriedades de transporte de cloretos, as melhorias advindas das adições minerais foram mais significativas, assim como no desempenho em relação à corrosão das armaduras. Desse modo, concluiu-se que a incorporação das diferentes adições minerais estudadas no presente trabalho alterou significativamente as propriedades do concreto, com destaque positivo para as propriedades associadas à durabilidade, nas quais os benefícios do uso da adição mineral são mais pronunciados.
52

A CORROSÃO DAS ARMADURAS NAS ESTRUTURAS DE CONCRETO ARMADO EM EDIFICAÇÕES DA PRIMEIRA METADE DO SÉCULO XX: UMA METOLOLOGIA PARA SUA DETECÇÃO / REBARS CORROSION IN STRUCTURAL CONCRETE BUILDINGS OF FIRST HALF OF THE 20TH CENTURY: A METODOLOGY FOR ITS DETECTION

Isaia, Gustavo de Aguiar 01 April 2010 (has links)
The corrosion study in actual concrete structures is a subject enough discussed as much in the academic ambience as in the professional one. The subject is relevant due the numberless pathology cases of corrosion in structural concrete that are reported, almost daily, in the technical sphere. Nevertheless, few are the studies on this phenomenon in structural concrete of the first half of the 20th century. Is common sense that these structures were executed in a different way from the actual, and its behavior in front of corrosion may be differentiated, however, little are the studies that analyze the behavior of these structures in front of this pathology. This dissertation, based on bibliographical study and author s experience, look for not only analyze the concrete structure characteristics of the first half of 20th century and its influence on the rebar corrosion, as also propose a methodology for its detection. The proposition of this theme is based in fact that many execution and calculus methods were enough different from the actual concerning the concrete structures. The sodium chloride and calcium chloride addition in concrete, with purpose to accelerate the set and curing of concrete, the use of wooden pins as spacers are some characteristics showed in this work. As conclusion, is proposed an evaluation methodology which permits analyze such structures under the optics of its peculiar characteristics, aiming at the rebar corrosion. / O estudo da corrosão em estruturas de concreto armado atuais é um assunto bastante discutido tanto no meio acadêmico, como no profissional. O tema reveste-se desta importância devido aos inúmeros casos de patologias de corrosão em estruturas de concreto armado que são reportados, quase diariamente, ao meio técnico. No entanto, pouco se tem estudado a respeito desse fenômeno em estruturas de concreto armado da primeira metade do século XX. É senso comum que essas estruturas foram executadas de forma diferente das atuais e que seu comportamento frente à corrosão pode ser diferenciado; no entanto, são poucos os estudos que analisam o comportamento desse tipo de estrutura frente a essa patologia. Este trabalho, tendo por base um estudo bibliográfico e a experiência do autor, busca não só analisar as características das estruturas de concreto armado da primeira metade do século XX e suas influências sobre a corrosão das armaduras, como também propor uma metodologia para sua detecção. A proposição desse tema baseia-se no fato de que muitos métodos de execução e cálculo eram bastante diferentes dos atuais no que concerne a estruturas de concreto armado. A adição de cloreto de sódio e cloreto de cálcio no concreto, com a finalidade de acelerar a pega e a cura do concreto, e o uso de tarugos de madeira como espaçadores são algumas das características mostradas neste trabalho. Como conclusão é proposta uma metodologia de avaliação que permita analisar tais estruturas sob a ótica de suas características particulares, com vistas à corrosão da armadura.
53

Sobre a modelagem numérica da difusão de cloretos no concreto: uma abordagem pelo método dos elementos de contorno com aplicação de modelos de confiabilidade e otimização / On the numerical modeling of diffusion of chlorides in concrete: an approach by the boundary element method with the application of reliability and optimization models

Pellizzer, Giovanni Pais 18 April 2019 (has links)
O principal mecanismo de transporte de íons cloreto pelos microporos do concreto é a difusão. Em um dado instante do processo difusivo, quando a concentração de cloretos na interface concreto/armadura atinge um valor limite, ocorre a despassivação das armaduras. É neste instante que se encerra a etapa de iniciação e onde se inicia a etapa de propagação da corrosão. Considerando-se que após o início da etapa de propagação a segurança estrutural decai rapidamente, devido aos diversos mecanismos deletérios ocasionados pela corrosão, é fundamental prever adequadamente quando se dará o seu início. Existem disponíveis na literatura diversos métodos para a análise da etapa de iniciação. Contudo, poucos utilizam o método dos elementos de contorno (MEC) para este fim. Além disso, devido à elevada aleatoriedade presente neste fenômeno, uma abordagem sob um ponto de vista probabilístico apresenta grande potencial para um tratamento adequado do problema. Por fim, objetivando encontrar configurações de projeto propícias a manutenção de um dado nível de segurança mínimo durante toda a vida útil estrutural, podem ser empregados modelos de otimização sob incertezas. Assim, o presente trabalho tem por objetivo apresentar uma formulação baseada no MEC que torne possível a análise determinística, probabilística e de otimização da etapa de iniciação para problemas de difusão no concreto em regime transiente. É descrita a formulação do problema e o esquema de resolução do mesmo, implementados computacionalmente. Exemplos de aplicação são apresentados validando e mostrando a eficiência das formulações adotadas. Destacam-se as limitações de soluções analíticas, as potencialidades da solução numérica e a grande influência que as condições de contorno exercem sobre o fenômeno. / Diffusion is the main transport mechanism of chloride ions through the micropores of concrete. At a given moment of the diffusive process, when the chloride concentration at the concrete/reinforcement interface reaches a threshold level, reinforcement depassivation occurs. At this point, the initiation stage ends and the corrosion propagation stage begins. Considering that after the start of the propagation stage the structural safety decays rapidly, due to the various deleterious mechanisms caused by corrosion, it is essential to adequately predict when it will start. Several methods for the analysis of the initiation stage are available in the literature. However, few of then use the boundary element method (BEM) for this purpose. Moreover, due to the high randomness present in this phenomenon, a probabilistic approach presents great potential for an adequate treatment of the problem. Finally, in order to find project configurations propitious to maintaining a given minimum level of safety during the entire useful structural life, optimization models under uncertainties can be used. Thus, the present work aims to present a formulation based on the BEM that makes possible the deterministic, probabilistic and optimization analysis of the initiation stage for unsteady state diffusion problems in concrete. The problem formulation and the implementation resolution scheme are described. Application examples are presented validating and showing the efficiency of the formulations adopted. The limitations of analytical solutions, the potentialities of the numerical solution and the great influence that the boundary conditions weigh on the phenomenon are highlighted.
54

Modelos numéricos aplicados à modelagem probabilística da degradação mecânica do concreto e corrosão de armaduras / Numerical models applied to the probabilistic modelling of the mechanical degradation of concrete and reinforcement corrosion

Coelho, Karolinne Oliveira 06 April 2017 (has links)
A corrosão de armaduras é uma das causas mais comuns de degradação mecânica em estruturas em concreto armado. Esse processo leva à redução da vida útil e, consequentemente, a prejuízos econômicos. Desse modo, o presente trabalho visa contribuir com a análise dos fenômenos associados à degradação mecânica do concreto armado sujeito a processos corrosivos devido à carbonatação e à ação de cloretos. Para tal finalidade, modelos analíticos baseados na segunda lei de Fick são usados para quantificar a difusão de CO2 e de íons cloreto no concreto, os quais permitem determinar o tempo de início da corrosão. A degradação mecânica de estruturas em concreto armado é considerada por meio de um modelo em dano concentrado que contempla perda da rigidez, redução da área de aço e da tensão de escoamento de armaduras devido ao processo corrosivo. A formulação de dano concentrado foi modificada de forma a incluir uma variável de estado de corrosão e uma lei de evolução da corrosão, baseada em equações semi-empíricas disponíveis na literatura. Essas equações determinam a redução no diâmetro das armaduras e a perda da capacidade resistente do aço. O problema da corrosão é formulado como um processo estocástico sendo resolvido por meio do método de simulação de Monte Carlo para dois exemplos: uma viga isostática e um pórtico plano com grau de hiperestaticidade igual a três. A formulação da equação de estado limite é baseada em um valor de dano aceitável. Curvas de probabilidade de início da corrosão e de probabilidade de falha da estrutura são obtidas ao longo de 50 anos. No caso da estrutura hiperestática, o caminho mais provável de falha, também chamado de caminho crítico, é determinado. Observa-se que o processo corrosivo provoca mudanças no caminho crítico, e portanto, deve ser considerado nas análises de reparo estrutural. Mapas de dano e de probabilidade de falha foram desenvolvidos para mostrar as mudanças no comportamento estrutural devido à corrosão. / The reinforcement\'s corrosion is one of the most common causes of mechanical degradation in reinforced concrete structures. This process leads to the reduction of the service life and, consequently, economic loss. Thereby, this study aims to contribute with the analysis of the phenomena associated to the mechanical degradation of reinforced concrete, due to the carbonation and the chloride ions. For this purpose, analytical models based on second Fick\'s law are used to quantify CO2 and chloride ions diffusion, which enables to determine the corrosion time initiation. The mechanical degradation of reinforced concrete structures is modeles by the lumped damage model which accounts for stiffness loss, reinforcement mass loss and yield stress reduction due to the corrosive process. The lumped damage formulation was modified to include the state corrosion variable and the corrosion evolution law based on semi-empirical equations available in the literature. These equations determine the reinforcement\'s diameter reduction and the loss of resistant capacity of the reinforcement\'s bar. The corrosion problem is formulated as a stochastic process and solved by the Monte Carlo simulation for two examples: an isostatic beam and a hyperstatic frame. The limit state functions are based on the acceptable damage value. Curves of probability of corrosion initiation and probability of failure are obtained over a range of 50 years. In the hyperstatic case, the most probable failure path, also named the critical path, is determined. It is observed that the corrosive process causes changes on the critical path and, therefore, it must be accounted on structural repair analysis. Damage and probability of failure maps were developed to show the changes on the structural behavior due to the corrosion.
55

Estudo dos parâmetros: teor de NaCl e acabamento superficial, na resistência à corrosão localizada e generalizada em tubos de cobre / Study of the parameters: NaCl concentration and surface finish on the pitting corrosion resistance of copper tubes

Jesus, Antonio Carlos Neto de 17 March 2008 (has links)
Tubos de cobre fabricados com o material ASTM C12200 (99,9%Cu-0,015-0,040%P) são utilizados mundialmente no transporte de água potável. A maior causa de vazamentos nestas tubulações é a corrosão por pite, que usualmente estão relacionadas com a qualidade da água. Estudos recentes mostraram que vazamentos em tubos de cobre usados para transporte de água de rede pública ocorreram em decorrência da corrosão por pite, o que se deu em virtude da presença do íon cloreto originado do tratamento para a desinfecção da água. Outro parâmetro que pode influenciar a corrosão por pite é a condição de acabamento interno dos tubos. Os óleos lubrificantes usados no processo de fabricação de tubos de cobre contêm carbono e este forma um filme deletério após o recozimento destes tubos. Este filme cria condições na superfície interna para a formação de pilhas de ação local. O objetivo deste trabalho é investigar se o teor de cloreto de sódio no meio aquoso, e o acabamento superficial da superfície interna de tubos de cobre utilizados comercialmente para transporte de água (ABNT/NBR-13206), têm influência na resistência à corrosão destes tubos. A resistência à corrosão foi investigada por meio de ensaios eletroquímicos em soluções naturalmente aeradas com várias concentrações de cloreto de sódio, a 25 oC. A superfície interna dos tubos foi observada, antes e após os ensaios eletroquímicos, por microscopia eletrônica de varredura (MEV). Os tipos de acabamentos superficiais estudados foram: desengraxamento, jateamento e acabamento do processo final de fabricação (sem tratamento). Foi também construído um circuito fechado para estudar o efeito do acabamento superficial na resistência à corrosão sob condições mais próximas das encontradas na prática. O efeito do tratamento de recozimento do tubo em atmosfera inerte, que causa a recristalização da microestrutura e eliminação dos resíduos de óleo lubrificante, também foi avaliado. Os resultados indicaram que o mecanismo de corrosão em soluções com teores de cloreto entre 0,06 mol L-1 e 0,12 mol L-1 correspondeu ao de ataque localizado, enquanto que para a concentração de 0,6 mol L-1 prevaleceu o ataque generalizado. Os resultados do estudo do efeito do acabamento superficial indicaram que os tratamentos que reduzem o teor de carbono na superfície são benéficos à resistência à corrosão, mas este não é o único fator que afeta a resistência à corrosão. Outras características superficiais resultantes do tratamento da superfície também devem ser consideradas. Por exemplo, embora o jateamento cause a diminuição do teor de carbono na superfície dos tubos, o aumento de rugosidade produzido por este acabamento pode resultar em uma menor resistência à corrosão. Os tratamentos superficiais que produziram superfície com maiores resistências à corrosão foram aqueles que também produziram superfícies com menores teores de carbono, a saber, desengraxe e recozimento. / Copper tubes manufactured with C12200 ASTM (99.9% Cu-0015-0040% P) are used worldwide for potable water transport. The largest number of leakages in these tubes is due to pitting, usually related to the water quality, associated to the presence of chloride ions originated from water disinfecting treatment. The literature on the effect of chloride on the corrosion of copper pipelines is controversial. The finishing of the copper tubes inner might also influence pitting corrosion. The lubricating oils used in the manufacture of copper tubes contain carbon and a deleterious film might form during annealing. The objective of this study is to investigate the effect of sodium chloride content and the inner surface finishing of copper tubes used for water transport (ABNT/NBR-13206) on their corrosion resistance. The study was carried out by electrochemical tests in naturally aerated sodium chloride solutions at various concentrations, at 25 °C. The tubes inner surface was observed previous to and after the electrochemical tests by scanning electron microscopy (SEM). The effects of the following surface finishing were investigated: degrease, sand blasting, annealing and the surface without treatment. A loop was built to simulate the operational conditions of the tubes. Results indicated that the corrosion mechanism in chloride solutions with concentrations between 0.06 mol L-1 and 0.12 mol L-1 was localized attack, whereas in the 0.6 mol L-1 solution, generalized attack was the predominant mechanism. The results the surface finishing investigation indicated that the treatments that leads to carbon content reduction are beneficial to corrosion resistance. However, other features must also be considered. For instance, although sand blasting reduces the carbon content on the tubes surface, the increase in roughness due to this treatment decreases the corrosion resistance. The surface treatments that resulted in increased corrosion resistance were those that also resulted in lower carbon levels at the surface, namely degreasing and annealing.
56

Corrosão sob tensão de um aço inoxidável austenítico em soluções aquosas contendo cloretos / Stress corrosion cracking of austenitic stainless steel in chlorides environments

Mariano, Neide Aparecida 20 February 1997 (has links)
No presente trabalho foi estudado o comportamento de um aço inoxidável austenítico do sistema Fe-Cr-Mn-N, nas condições como recebido, solubilizado e sensitizado, quando submetidos à meios contendo cloretos. Para analisar a suscetibilidade à corrosão sob tensão foram utilizados corpos de prova dos tipos DCB (\"Double Cantilever Beam\") e C(T) (\"Compact- Tension\"), pré-trincados em fadiga, com entalhes laterais e carregados com cunhas. Os meios empregados foram as soluções aquosas 45% em peso de MgCl2 na temperatura de ebulição de 154°C, água do mar sintética na temperatura ambiente e de ebulição de 100°C e 3,5% em peso de NaCI na temperatura ambiente. A suscetibilidade à corrosão sob tensão foi avaliada em termos do fator limite de intensidade de tensão, KISCC, e foram caracterizados os aspectos fractográficos dos corpos de prova em que ocorreram propagação de trinca por corrosão sob tensão. Foi verificado que apenas os corpos de prova do aço E3949 nas condições como recebido e sensitizado, foram suscetíveis à corrosão sob tensão em solução aquosa de 45% em peso de MgCl2 na temperatura de ebulição. Também foi determinado o comportamento eletroquímico do material nas condições citadas acima com relação aos meios empregados. Os resultados das curvas de polarização obtidas mostraram que o material apresenta baixa resistência à corrosão, principalmente em meios de MgCl2. / The present work studies the stress corrosion cracking behavior in austenitic Fe-Cr-Mn-N stainless steel, in as received, solubilized and sensitized conditions, when submited to several chlorides environments. To evalued the stress corrosion cracking susceptibility, DCB (\"Double Cantilcver Beam\") and C(T) (\"Compact- Tension\") specimens, fatigue precracked, side grooved and wedge loaded were used. The environments employed were boiling solution of 45 wt% of MgCl2 at 154ºC, synthetic sea water at room and 100°C temperatures, and a solution with 3,5 wt% of NaCI at room temperature. The susceptibility to stress corrosion cracking has been evaluated in terms of the threshold stress intensity factor, KISCC, and the fracture surface appearance of those specimens whose the crack propagation took place was characterized. The results showed that only the specimens in the as received and sensitized conditions, were suceptible to the stress corrosion cracking effect in the solution with 45 wt% of MgCl2 at the boilling temperature. Also, it has been verified the electrochemical behavior of this steel when submited in the above environments. The results of polarization curves showed that the material presents low corrosion strength, mainly in MgCl2 environments.
57

Estudo dos parâmetros: teor de NaCl e acabamento superficial, na resistência à corrosão localizada e generalizada em tubos de cobre / Study of the parameters: NaCl concentration and surface finish on the pitting corrosion resistance of copper tubes

Antonio Carlos Neto de Jesus 17 March 2008 (has links)
Tubos de cobre fabricados com o material ASTM C12200 (99,9%Cu-0,015-0,040%P) são utilizados mundialmente no transporte de água potável. A maior causa de vazamentos nestas tubulações é a corrosão por pite, que usualmente estão relacionadas com a qualidade da água. Estudos recentes mostraram que vazamentos em tubos de cobre usados para transporte de água de rede pública ocorreram em decorrência da corrosão por pite, o que se deu em virtude da presença do íon cloreto originado do tratamento para a desinfecção da água. Outro parâmetro que pode influenciar a corrosão por pite é a condição de acabamento interno dos tubos. Os óleos lubrificantes usados no processo de fabricação de tubos de cobre contêm carbono e este forma um filme deletério após o recozimento destes tubos. Este filme cria condições na superfície interna para a formação de pilhas de ação local. O objetivo deste trabalho é investigar se o teor de cloreto de sódio no meio aquoso, e o acabamento superficial da superfície interna de tubos de cobre utilizados comercialmente para transporte de água (ABNT/NBR-13206), têm influência na resistência à corrosão destes tubos. A resistência à corrosão foi investigada por meio de ensaios eletroquímicos em soluções naturalmente aeradas com várias concentrações de cloreto de sódio, a 25 oC. A superfície interna dos tubos foi observada, antes e após os ensaios eletroquímicos, por microscopia eletrônica de varredura (MEV). Os tipos de acabamentos superficiais estudados foram: desengraxamento, jateamento e acabamento do processo final de fabricação (sem tratamento). Foi também construído um circuito fechado para estudar o efeito do acabamento superficial na resistência à corrosão sob condições mais próximas das encontradas na prática. O efeito do tratamento de recozimento do tubo em atmosfera inerte, que causa a recristalização da microestrutura e eliminação dos resíduos de óleo lubrificante, também foi avaliado. Os resultados indicaram que o mecanismo de corrosão em soluções com teores de cloreto entre 0,06 mol L-1 e 0,12 mol L-1 correspondeu ao de ataque localizado, enquanto que para a concentração de 0,6 mol L-1 prevaleceu o ataque generalizado. Os resultados do estudo do efeito do acabamento superficial indicaram que os tratamentos que reduzem o teor de carbono na superfície são benéficos à resistência à corrosão, mas este não é o único fator que afeta a resistência à corrosão. Outras características superficiais resultantes do tratamento da superfície também devem ser consideradas. Por exemplo, embora o jateamento cause a diminuição do teor de carbono na superfície dos tubos, o aumento de rugosidade produzido por este acabamento pode resultar em uma menor resistência à corrosão. Os tratamentos superficiais que produziram superfície com maiores resistências à corrosão foram aqueles que também produziram superfícies com menores teores de carbono, a saber, desengraxe e recozimento. / Copper tubes manufactured with C12200 ASTM (99.9% Cu-0015-0040% P) are used worldwide for potable water transport. The largest number of leakages in these tubes is due to pitting, usually related to the water quality, associated to the presence of chloride ions originated from water disinfecting treatment. The literature on the effect of chloride on the corrosion of copper pipelines is controversial. The finishing of the copper tubes inner might also influence pitting corrosion. The lubricating oils used in the manufacture of copper tubes contain carbon and a deleterious film might form during annealing. The objective of this study is to investigate the effect of sodium chloride content and the inner surface finishing of copper tubes used for water transport (ABNT/NBR-13206) on their corrosion resistance. The study was carried out by electrochemical tests in naturally aerated sodium chloride solutions at various concentrations, at 25 °C. The tubes inner surface was observed previous to and after the electrochemical tests by scanning electron microscopy (SEM). The effects of the following surface finishing were investigated: degrease, sand blasting, annealing and the surface without treatment. A loop was built to simulate the operational conditions of the tubes. Results indicated that the corrosion mechanism in chloride solutions with concentrations between 0.06 mol L-1 and 0.12 mol L-1 was localized attack, whereas in the 0.6 mol L-1 solution, generalized attack was the predominant mechanism. The results the surface finishing investigation indicated that the treatments that leads to carbon content reduction are beneficial to corrosion resistance. However, other features must also be considered. For instance, although sand blasting reduces the carbon content on the tubes surface, the increase in roughness due to this treatment decreases the corrosion resistance. The surface treatments that resulted in increased corrosion resistance were those that also resulted in lower carbon levels at the surface, namely degreasing and annealing.
58

Avaliação do valor nutricional e ocorrência de óxidos de colesterol em peixe mandim (Arius spixii) comercializado em Maceió-AL.

Oliveira, Fabiana Rodrigues de 20 July 2007 (has links)
Fish has long been highly regarded for its significant nutritional value. However, the presence of highly unsaturated fatty acids and high levels of cholesterol in some species, associated to the technological procedures employed in the processing, favor the oxidation of cholesterol. Cholesterol oxides are linked to adverse biological effects such as cytotoxicity, atherogenicity, mutagenicity, and carcinogenicity. Important issues related to cholesterol oxides, their formation in food, and their biological effects were revised in this paper, mainly addressing their occurrence in fish. In view of the lack of information regarding the chemical composition of locally consumed fish, an assessment was made of the nutritional value and the occurrence of cholesterol oxides in the mandim fish (Arius spixii) marketed in Maceió-AL, Brazil. Centesimal composition, calorie count, chloride, fatty acid and cholesterol profile, and cholesterol oxide levels were determined for both fresh and processed (salted-dried) fish. Respective results for fresh and processed mandim fish were: moisture (70.13% and 40.31%), proteins (51.73% and 38.07%, dried), carbohyrdrates (4.67% and 2.24%, dried), calories (485.61 kcal/100g and 366.89 kcal/100g, dried), fatty acids (omega-3 8.51% and 6.51%), cholesterol (82.66 mg/100g and 61.30 mg/100g) and oxides (7-ketocholesterol 8.31 μg/g and 17.90 μg/g). These figures led to the conclusion that the mandim fish has significant nutritional value, although the lack of criteria and proper technique in its processing did promote the loss of nutrients and the formation of cholesterol oxides, thus highlighting the need for a thorough assessment of the procedures employed in handling the locally consumed fish in order to implement measures to safeguard its quality. / O pescado tem sido destacado como alimento de significativo valor nutricional. Mas a presença em sua fração lipídica de ácidos graxos com alto grau de insaturação e de níveis elevados de colesterol em algumas espécies, associada aos procedimentos tecnológicos a que são submetidos, favorece a oxidação do colesterol. Os óxidos de colesterol estão relacionados a efeitos biológicos adversos como citotoxidade, aterogenicidade, mutagenicidade e carcinogenicidade. Neste trabalho, foram revisadas questões importantes envolvendo os óxidos de colesterol, sua formação em alimentos e efeitos biológicos, enfocando aspectos da sua ocorrência em pescado. Foram avaliados ainda, considerando a escassez de informações a cerca da composição química do pescado de consumo regional, o valor nutricional e a ocorrência de óxidos de colesterol no peixe mandim (Arius spixii) comercializado em Maceió-AL, sendo determinados nas suas formas in natura e beneficiada (salgado-seco) a composição centesimal, valor calórico, cloretos, perfil de ácidos graxos, colesterol e óxidos de colesterol. Os resultados obtidos para o mandim in natura e beneficiado, respectivamente, de umidade (70,13% e 40,31%), proteínas (51,73% e 38,07%, base seca), carboidratos (4,67% e 2,24%, base seca), calorias (485,61 kcal/100g e 366,89 kcal/100g, base seca), ácidos graxos (ômega-3 8,51% e 6,51%), colesterol (82,66 mg/100g e 61,30 mg/100g) e óxidos (7-cetocolesterol 8,31 μg/g e 17,90 μg/g), permitiram concluir que o mandim é um peixe de significativo valor nutricional, mas que o beneficiamento, procedido sem técnica e critérios, favoreceu a perda de nutrientes e a formação de derivados oxidados do colesterol, indicando a necessidade de avaliação mais completa dos procedimentos de manipulação do pescado consumido e comercializado na região para implantação de medidas que assegurem o controle de sua qualidade. Palavras-chave: peixe, Arius spixii, composição centesimal, cloretos, ácidos graxos, colesterol, óxidos de colesterol.
59

ESTUDO DA UTILIZAÇÃO DE CINZA DA CASCA DO ARROZ RESIDUAL EM CONCRETOS ESTRUTURAIS: UMA ANÁLISE DA DURABILIDADE AOS CLORETOS / UTILIZATION STUDY OF RESIDUAL RICE RUSK ASH IN STRUCTURAL CONCRETE: AN ANALYSIS OF THE CHLORIDE DURABILITY

Pedrozo, Eder Claro 27 March 2008 (has links)
The use of residues, as the rice husk ash (RHA) in the concrete s production reduces the environmental impact caused in its productive chain. It means fewer energy s consumption, fewer natural resources waste, less environmental pollution and lower aggregated cost. In the present study, the viability of using residual RHA, in natura (non-ground) or ground, on structural concrete, in partial substitution to the Portland cement was investigated, starting from the durability chloride ions analysis. In such a way, five cementitious blends, two composed by natural RHA, two with crushed RHA and one as a reference sample were tested. The substitution s rates were 15% and 25%. The water/binder relations used were 0.45, 0.55 and 0.65. The samples were tested for chloride penetration according to ASTM C 1202 (Rapid Chloride Permeability Test) and for long-term test (colorimetric method). Additionally, the tests of axial compressive strength and water absorption by immersion, according to the ABNT prescriptions were conducted. The obtained results showed that is viable to use residual non-ground RHA as partial substitution to Portland cement in structural concretes. For the axial compressive strength at 91 days and to the same relation w/b, in general, the residual non-ground RHA blends showed higher performance than those presented by the reference mixture. In the RCPT the use of RHA resulted in decreases in the passing charges that, in general, promoted improvement in the mixtures ratings on the chloride penetrability, compared with the reference mixtures. In long-term test, the use of RHA burnt without temperature control, also promoted improvements in the mixture performances, compared to the reference mixtures, with reductions in the chloride penetration coefficients. But the mixtures were dissimilar when compared to those presented by the RCPT. In the case of water absorption by immersion, it was found that the use of RHA, in general, increased the concrete water absorption, however, the results presented by mixtures composed with RHA were close to those of reference ones. / A utilização de resíduos como a cinza da casca do arroz produzida sem controle da temperatura na fabricação de concretos reduz o impacto ambiental gerado na cadeia produtiva deste material, significando menor consumo de energia, menor desperdício de recursos naturais, menor poluição do meio ambiente e menor custo agregado. No presente trabalho investiga-se a viabilidade de se utilizar a CCA residual, ao natural ou moída, em concretos estruturais, em substituição parcial ao cimento Portland, a partir da análise da durabilidade aos ions cloretos. Para isso, foram testadas cinco misturas aglomerantes: duas compostas com CCA ao natural, duas com CCA moída e uma mistura de referência com 100% cimento Portland, a qual se confrontaram os resultados. Adotaram-se os teores de substituição de 15% e 25%, e as relações a/ag de 0,45; 0,55 e 0,65. Procederam-se os ensaios de resistência à penetração de cloretos segundo o método de penetração acelerada ASTM C 1202 (EAPC) e também, segundo o método de imersão em solução salina (EPCI). Adicionalmente, foram realizados os ensaios de resistência à compressão axial e de absorção de água por imersão, segundo prescrições da ABNT. Os resultados obtidos na investigação confirmam que é viável utilizar a CCA residual, ao natural ou moída, como substituição parcial ao cimento Portland, em concretos para uso estrutural. Quanto à resistência a compressão axial, aos 91 dias, as misturas compostas CCA, em geral, apresentaram desempenhos superiores aos das misturas de referência. No EAPC a utilização de CCA resultou em decréscimos nos valores das cargas passantes que, em geral, promoveram melhoria nas classificações das misturas quanto à penetrabilidade aos cloretos, em comparação as misturas de referência. No EPCI a utilização da CCA, queimada sem controle de temperatura, também promoveu melhorias no desempenho da maioria das misturas, em comparação às misturas de referência, com reduções nos coeficientes de penetração de cloretos. Porém as misturas apresentaram comportamentos diferenciados quando comparados ao apresentado no EAPC. No caso da absorção de água por imersão, constatou-se que a utilização de CCA, em geral, aumentou a absorção de água dos concretos, entretanto, os valores apresentados pelas misturas compostas com CCA foram próximos aos de referência.
60

Retração total e penetração de cloretos em concretos com cimento Portland branco e escória de alto forno / Total shrinkage and chloride penetration in concretes with white Portland cement and blast furnace slag

Dellinghausen, Luciano de Medeiros 25 June 2009 (has links)
Drying Shrinkage is a phenomenon that occurs in concrete, subjected or not to a load, due to water loss, once exposed to environment and allowed to dry. It is responsible for almost the entire total shrinkage strain in concrete. A concrete element with restrained shrinkage deformation may develop tensions that cause cracks, allowing the ingress of aggressive agents that may cause some damage to the reinforcement, reducing, consequently, its strength and durability. The most common aggressive agent into concrete is the chloride ion, which is considered the great responsible for the early reinforcement corrosion of concrete structures, affecting its stability and durability. Corrosion of reinforcement bars due to the ingress of salts from sea water into concrete is recognized to be the most influent factor in the destructive mechanisms for marine structures. The use of mineral admixtures such as blast furnace slag, the increase of curing duration and the water/binder ratio reduction are measures that may reduce the chloride ion penetration. The aim of this study was to investigate the influence of the cement replacement content by slag, as well as the duration of curing on drying shrinkage, chloride ion penetration and compressive strength of concretes made with high early age strength cement and white Portland cement. Water-binder ratios of 0.30, 0.42 and 0.55, curing duration of 3 and 7 days, besides the cement replacement contents of 0%, 50% and 70% were investigated. In order to analyze the influence of the alkali activation on the properties investigated, a concrete made with 50% white Portland cement replacement content by slag and activated by sodium sulfate (4% in mass of binder) was used. The compressive strength was evaluated in the ages of 3, 7, 28 and 91 days; the drying shrinkage in the ages of 7, 14, 21, 28, 35, 56, 91 and 182 days, and the chloride ion penetration (immersion test in chloride solution) in the ages of 7, 14, 28, 56 and 91 days. Before being immersed in the chloride solution, the specimens were subjected to a drying period of 91 days. The results obtained revealed that an increase in the slag content decreased the compressive strength and the drying shrinkage values, besides the smaller depths of chloride penetration with both cements used. Reducing the curing duration resulted greater drying shrinkage and depth of chloride penetration for both cements, independently the slag content. / A retração hidráulica é um fenômeno que ocorre no concreto, submetido ou não a carregamento, devido à perda de umidade, uma vez exposto ao meio ambiente e permitida sua secagem. Ela é responsável por praticamente toda a deformação total por retração no concreto. Um elemento de concreto com restrição de deformação por retração pode desenvolver tensões que levam à formação de fissuras, através das quais agentes agressivos podem penetrar e causar algum dano à armadura, reduzindo sua resistência e durabilidade. O agente agressivo mais comum é o íon cloreto, o qual é considerado como a maior causa de corrosão prematura das barras de armaduras das estruturas de concreto, afetando sua estabilidade e vida útil. A corrosão de armaduras devido ao ingresso de íons cloretos da água do mar no concreto é universalmente conhecida como o fator de maior influência nos mecanismos destrutivos de estruturas marinhas. A utilização de adições minerais como a escória de alto forno, o aumento no prazo de cura e a redução na relação água/aglomerante são medidas que podem diminuir a penetração desses íons no concreto. Este trabalho teve por objetivo investigar a influência do teor de escória e do período de cura na retração hidráulica, na penetração de íons cloretos e na resistência à compressão axial de concretos compostos de cimento Portland de alta resistência inicial e cimento Portland branco estrutural. Foram adotadas relações água/aglomerante de 0.30, 0.42 e 0.55, teores de escória, em substituição ao cimento Portland, de 0%, 50% e 70%, além de períodos de cura de 3 e 7 dias. Foi empregada uma mistura composta de 50% de escória em substituição ao cimento Portland branco, ativada quimicamente por sulfato de sódio (4% da massa de aglomerante) para analisar a influência do ativador nas propriedades investigadas. As idades avaliadas para o ensaio de resistência à compressão foram de 3, 7, 28 e 91 dias; para retração hidráulica idades de 7, 14, 21, 28, 35, 56, 91 e 182 dias e, para penetração de íons cloretos (imersão em solução salina) as idades de 7, 14, 28, 56 e 91 dias. Antes de serem imersos em solução salina os corpos-de-prova foram submetidos a um período de secagem de 91 dias. Dos resultados obtidos, constatou-se que o aumento do teor de escória resultou em decréscimo nos valores de resistência à compressão, de retração e de penetração de cloretos para os dois cimentos investigados. A diminuição no período de cura resultou em maiores valores de retração e de penetração de cloretos, tanto no concreto branco quanto no cinza, independentemente do teor de escória utilizado.

Page generated in 0.1511 seconds