• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 180
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 197
  • 197
  • 99
  • 98
  • 69
  • 55
  • 42
  • 38
  • 23
  • 23
  • 22
  • 22
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Influência do bisel na resistência à fratura de dentes restaurados com resina composta / The influence of bevel in the fracture resistance of teeth with composite resin restorations

Valera, Fabiano Bassalobre 16 October 2007 (has links)
Avaliou-se a resistência à fratura de dentes pré-molares, com e sem bisel no ângulo cavo-superficial, restaurados com resina composta. Noventa dentes prémolares superiores foram divididos em 9 grupos. O grupo 1, considerado controle positivo, constituiu-se de dentes hígidos. Os grupos de 2 a 9 receberam cavidades de Classe II MOD, com medidas padronizadas. Os grupos de 6 a 9, além das cavidades, tiveram os tetos das câmaras pulpares removidos. Para os grupos 2, 3, 6 e 7, o ângulo cavo-superficial apresentou-se nítido e sem bisel; grupos 4 e 8, bisel côncavo em toda cavidade; grupos 5 e 9, bisel apenas na porção oclusal da cavidade. Os dentes dos grupos 2 e 6 não foram restaurados, sendo considerados controle negativo. Para os demais grupos, procedeu-se a restauração das cavidades com sistema restaurador adesivo pela técnica direta. Todos os espécimes foram avaliados quanto a resistência à fratura, em uma maquina de teste universal (Emic - DL 2000), com célula de carga de 500Kgf, regulada a uma carga máxima de 450Kgf, com uma leitura mínima de 0,05Kgf de precisão. Os resultados foram submetidos à análise de variância a um critério e ao teste de Tukey para comparação entre os grupos. Constatou-se que houve diferença significante entre os grupos estudados, quando considerados os diferentes tratamentos do ângulo cavo-superficial (variável independente) e a resistência à fratura obtida (variável dependente) (p<0,05). A remoção de tecido dentário pela confecção de cavidades diminuiu a resistência à fratura do órgão dentário, sendo que em intervenções mais extensas, com a remoção de estrutura de reforço, como o teto da câmara pulpar, esta resistência se apresentou ainda menor. A confecção de bisel em todo o ângulo cavo-superficial, em cavidades de Classe II, proveu um aumento significante da resistência à fratura, quando comparado aos dentes que apresentaram o ângulo cavo-superficial nítido e sem bisel, tanto em dentes com ou sem remoção do teto da câmara pulpar. Além disso, dentes que apresentaram bisel em todo o ângulo cavo-superficial de cavidades de Classe II, tanto com ou sem intervenção endodôntica, mostraram os melhores padrões de fratura, preservando quase que em sua totalidade a integridade do remanescente dentário. / The fracture resistance of upper premolar teeth with and without cavosurface bevel, restored with composite resin material was evaluated. Ninety upper premolar teeth were divided into 9 groups. The group 1, considered as a positive control, was composed of sound teeth. Groups 2 to 9 receive Class II MOD preparation cavities with standardized measures. Groups from 6 to 9 had the roof of the pulp chamber removed. In groups 2, 3, 6, and 7, the cavosurface angle was evident and without bevel; groups 4 and 8, a concave bevel around the entire cavity; groups 5 and 9, the bevel was only placed in the oclusal portion of the cavity. Teeth in groups 2 and 6 were not restored, and considered as negative controls. In the other groups, cavities were directly restored with an adhesive resin system. All specimens were evaluated until load to fracture in a Universal Testing Machine (Emic DL 2000), with a load cell of 500Kgf, maximum load of 450Kgf, and 0,05kgf of standard error. Results were submitted to one-way analysis of variance and Tukey\'s test for group comparisons. There was a significant difference among the studied groups regarding the different treatments on the cavosurface angle (independent variable) and the fracture resistance (dependent variable) (p<0.05). Removal of tooth structure through cavity preparation diminished the fracture resistance values, being that in more extensive preparation (removal of the roof of pulp chamber), this value was lower. The bevel placed around the entire cavosurface angle in Class II cavities significantly increased the fracture resistance, when compared to teeth with a clear cavosurface angle but without bevel, either in teeth with or without removal of the roof of pulp chamber. Besides, teeth with bevel around the entire cavosurface angle with or without endodontic therapy showed the best fracture patterns, almost completely preserving tooth integrity.
162

Influência de propriedades físico químicas dos materiais resinosos e da técnica de inserção na adaptação marginal de restaurações classe II / Influence of physicochemical properties of resin materials and insertion technique on marginal adaptation of class II restorations

Silvia Maria Ribeiro de Alencar Gonçalves 25 February 2013 (has links)
A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFilSDR (Dentsply) (SDR), resina flow FiltekZ350Flow (3M/ESPE) (Z350F) e resina composta FiltekP90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas. / The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil SDR (Dentsply) low shrinkage resin (SDR), Filtek Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal adaptation; correlation exists between flexural strength, elastic modulus, shrinkage stress and material composition, since better results were obtained from composites with larger quantity of load; higher conversion degree did not represent better mechanical properties.
163

Influência da fonte de luz fotoativadora nas propriedades ópticas de resína composta, em função da cor, espessura e tempo de armazenamento

Queiroz, Renato Souza [UNESP] 10 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-10Bitstream added on 2014-06-13T19:40:56Z : No. of bitstreams: 1 queiroz_rs_dr_arafo.pdf: 679998 bytes, checksum: 47166f3c2a2f40adf0235d9237b0bd24 (MD5) / Esse estudo se propõe a avaliar as propriedades ópticas (Fluorescência e Absorbância) da resina composta fotoativada (4 SEASONS®) utilizando aparelho fotopolimerizador convencional (luz Halógena Ulttralux - DabiAtlant), e aparelho emissor de Diodo (Radii – SDI e Ultralume Led 5- Ultradent), em função da fonte de luz foto-ativadora, cor, espessura e tempo de armazenamento em saliva artificial. Foram confeccionadas 5 amostras (10,0x1,0 mm) para cada grupo experimental. Para a realização do teste de Absorbância foi utilizado aparelho espectrofotômetro de luz visível (Diode Array Spectrophotometer, HP – Serial Number: 8452-A). Para a obtenção dos valores de fluorescência emitida pelas amostras, foi utilizado espectrofotômetro (SPEX TRIAX FLUOROLOG 3, Jobin Yvon – Serial Number: 0135B-3-99). Os resultados foram julgados estatisticamente conforme a interação entre os fatores de avaliação nos distintos trabalhos. Pode-se concluir que a fonte de luz fotoativadora influenciou apenas a emissão fluorescente da resina de cor TC, não tendo efeito negativo na absorbância; o aumento na espessura da amostra acarretou uma diminuição na emissão fluorescente e na absorbância de todas as cores da resina, independente da fonte de luz; e as diferentes cores da resina exibiram diferentes emissões fluorescentes e absorbância... / The arm of this study is to evaluate optical properties (fluorescence and Absorbance) of a composite resin (4 SEASONS®) using light curing units (LCUs)-(QTH - Ulttralux – DabiAtlant and LEDs Radii – SDI and Ultralume Led 5- Ultradent) in function of LCUs, shade, thickness and storage times. 5 samples were prepared for each experimental group. To perform the Absorbance test, was used of UV-Vis spectrophotometer (Diode Array Spectrophotometer, HP – Serial Number: 8452-A). To obtain the fluorescence emission by samples, we used a spectrophotometer (SPEX TRIAX FLUOROLOG 3, Jobin Yvon – Serial Number: 0135B-3-99). The results were deemed statistically as the interaction between the evaluation factors in the different works. It can be concluded that the LCUs only influenced the fluorescent emission of resin color TC, having no negative effect on the absorbance; the increase in thickness of the sample decrease the fluorescent emission and absorbance for colors of the resin, independent of the LCUs; different colors of resin exhibited different fluorescent emission and absorbance.
164

Influência de diferentes resinas compostas e técnicas de polimento sobre os tecidos periodontais próximos a lesões cervicais não cariosas avaliação clínica randomizada

Teixeira, Nancielli 23 February 2015 (has links)
Made available in DSpace on 2017-07-10T14:57:28Z (GMT). No. of bitstreams: 1 Nancielli Teixeira - Influencia de diferentes_ resinas e tecn.pdf: 1668593 bytes, checksum: 73d67bc8169b66441386241284104ea5 (MD5) Previous issue date: 2015-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the influence of different composite resins and technical polishing and finishing over periodontals tissues and gingival crevicular fluid in cervical lesions restorations noncarious (LCNC). Initially were evaluated 272 teeths of patients with complaints related to LCNC and, acordding to the inclusion and exclusion criteria were selected 60 teeths for elegibility. Each tooth received a restoration with a kind of composite resin (Resin Tetric N-Ceram® or Resin Z350 XT®) in both quadrants, varying the polishing technique ( Astropol® Polishing rubber or Sof-lex® Disks). Periodontal tissues analysis, the longitudinal evaluation of restaurations and the gengival crevicular fluid collect were taken prior to scalling and root planning and also at 30, 60, 120 and 180 days of restaurations making. After the data collection and tabulation , these were submited to the Friedman test, with a significance level of 5%. The results revealed that resins and polishing techniques applied in this study showed no estatistical differences at the end of follow-up in any of the analyzes. However all groups evaluated showed differences between the initial and final times (p <0.05). From the results obtained it was concluded that regardless of the restorative material or polishing technique, the restoration of LCNC cavities improved the periodontal health of patients / O objetivo desse trabalho foi avaliar a influência de diferentes resinas compostas e técnicas de acabamento e polimento sobre os tecidos periodontais e o fluído crevicular gengival em restaurações de lesões cervicais não cariosas. Foram avaliados inicialmente 272 dentes de pacientes com queixas relacionadas à LCNC e, a partir dos critérios de inclusão e exclusão definidos, foram selecionados para elegibilidade 60 dentes, divididos em 4 grupos com N:15 dentes. Cada dente recebeu restauração com um tipo de resina composta nanoparticulada (Resina Tetric N-Ceram® ou Resina Z350 XT®) nos dois hemiarcos, variando a técnica de polimento (Borrachas de polimento Astropol® ou Discos Sof-lex®). A análise periodontal dos tecidos, a avaliação longitudinal das restaurações e a coleta do fluido crevicular gengival foram realizadas antes da raspagem e alisamento corono-radicular, e também aos 30, 60, 120 e 180 dias após a confecção das restaurações. Após a obtenção e tabulação dos dados, esses foram submetidos ao teste de Friedman, com nível de significância de 5%. Os resultados revelaram que as resinas e as técnicas de polimento utilizadas neste estudo não apresentaram diferenças estatísticas ao final do período de acompanhamento em nenhuma das análises. Porém, todos os grupos avaliados apresentaram diferenças entre os tempos iniciais e finais (p<0,05). A partir dos resultados obtidos foi possível concluir que, independente do material restaurador ou da técnica de polimentos utilizada, a restauração das cavidades de LCNC proporcionou melhora da saúde periodontal dos pacientes
165

"Diferentes métodos de otimização da polimerização de resinas compostas de uso direto" / Different methods in optimizing the polymerization of direct resin composites

Almeida, Ana Maria Lima 09 December 2005 (has links)
Este trabalho avaliou a influência da densidade de energia da pré-cura, e de diferentes tratamentos pós-cura na otimização das propriedades físicas (Resistência à Flexão e Dureza Knoop) de resinas compostas diretas, visando a possibilidade de indicação para restauraçoes indiretas. Foram usadas as resinas diretas Fillmagic, Concept, Glacier, Z100, Masterfill e W3D Master e as indiretas Solidex e Belleglass HP como controle. Para cada resina direta foram confeccionados 60 espécimes em barra (10x2x2mm), 30 irradiados em uma face e 30 nas duas faces (30 espécimes = 10 controle, 10 autoclave e 10 forno de luz). Para as resinas indiretas foram preparados 10 espécimes conforme processamento de seus fabricantes. 380 espécimes foram submetidos ao ensaio de resistência à flexão (Kratos). De cada condição experimental, 10 fragmentos foram usados para ensaio de microdureza Knoop (Shimadzu HMV-2). A análise de variância e o teste de Tukey demonstraram significância para resistência à flexão nos fatores Resina (p<0,001) e Tratamento (p=0,001) e na interação Resina x Tratamento (p=0,001). Para a microdureza Knoop os três fatores e as interações foram significantes: Resina (p=0,001); Face (p=0,001) Tratamento (p=0,017); Resina x Face (p=0,001); Resina x Tratamento (p=0,007); Face x Tratamento (p=0,001) e Resina x Face x Tratamento (p=0,024). A maior média de cada resina direta, independente da condição experimental, foi comparada às médias das resinas indiretas. Os resultados apontam que na resistência à flexão (Z100 = W3D = Fillmagic = Glacier) e (Z100 > Masterfill > Belleglass HP > Concept > Solidex). Na Dureza Knoop (Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill e Solidex). Conclusão: as propriedades físicas (resistência à flexão e dureza Knoop) não são obstáculos na indicação de resinas compostas de uso direto para restaurações indiretas / This study evaluated the influence of pre-cure energy density, and additional post-cure treatments in optimizing the physical properties (Flexural strength and Knoop microhardness) of direct resin composites with the aim at allowing their use for indirect restorations. Direct resin composites evaluated were Fillmagic, Concept, Glacier, Z100, Masterfill and W3D Master; indirect composites were Solidex and Belleglass HP. Sixty bar-shaped specimens (10x2x2mm) were prepared for each material, so that 30 of them were light-cured by one surface and 30 on both surfaces. From the 30 specimens of each group, 10 were control, 10 were submitted to additional autoclave and 10 to light oven treatment. Ten specimens were prepared with each indirect composite following the manufactures’ recommendations. The 380 specimens were submitted to flexural strength test (Kratos universal testing machine), and values obtained at fracture were reported. After that, 10 fragments were chosen for each experimental condition and assessed for Knoop microhardness (Shimadzu HMV-2). Data were submitted to analysis of variance and Tukey’s test at p<0.05. Statistically significant differences were found among flexural strength results regarding composite materials (p<0.001), treatments (p<0.001) and interactions (composite x treatment, p<0.001). Regarding Knoop microhardness, both three factors and their interactions were also significant: composite (p<0.001), surface (p<0.001) and treatment (p<0.017), composite x surface (p<0.001), composite treatment (p<0.001), surface x treatment (p<0.001) and composite x surface x treatment (p<0.024). The highest mean value for each direct composite, regardless of the experimental condition, was compared to the mean values obtained for the indirect materials. With regard to flexural strength, comparisons point out that Z100 = W3D = Fillmagic = Glacier and Z100 > Masterfill > Belleglass HP > Concept > Solidex, whereas for Knoop microhardness Z100 > Belleglass HP, Fillmagic, W3D, Concept, Glacier, Masterfill and Solidex. Conclusion: considering the physical properties evaluated in this study, they are not an obstacle to the indication of direct composites for indirect restorations
166

Eficácia da remoção parcial de tecido cariado em dentes decíduos : ensaio clínico controlado randomizado

Franzon, Renata January 2012 (has links)
A remoção parcial de tecido cariado (RPTC) em lesões profundas de cárie em dentes decíduos tem demonstrado excelentes resultados clínicos, radiográficos e microbiológicos. No entanto, o desempenho das restaurações com resina composta em dentes que tiveram esse tratamento ainda merece esclarecimentos. O objetivo desse trabalho foi investigar a taxa de manutenção de restaurações sobre tecido cariado através de uma revisão sistemática de literatura e de um ensaio clínico controlado randomizado. Métodos: Cinquenta e uma crianças de 3 a 8 anos de idade (28 meninos e 23 meninas) portadoras de ao menos um molar com lesão profunda de cárie foram incluídas no estudo. Os dentes foram aleatoriamente divididos de acordo com os seguintes tratamentos: Grupo controle: Remoção total de tecido cariado (RTTC) e teste: Remoção parcial de tecido cariado (RPTC). Nos casos em que ocorreu exposição pulpar foi realizada pulpotomia. Três Odontopediatras realizaram os procedimentos que foram acompanhados em 3, 6,12, 18 e 24 meses. Todos os procedimentos foram realizados sob anestesia local e isolamento absoluto. No início e no final do procedimento as crianças reportaram sua ansiedade através de duas escalas: Venham Picture Test (VPT) e Facial Image Scale (FIS). O comportamento da criança durante o atendimento foi avaliado através da escala de Sarnat. Em todos os momentos experimentais foram avaliados os aspectos clínicos e radiográficos dos tratamentos e as restaurações foram analisadas por um examinador cego e calibrado através do USPHS modificado.Para determinar as taxas de sucesso clínico e radiográfico e das restaurações de resina composta foram geradas curvas de sobrevida com o estimador Kaplan-Meyer. A distribuição dos indivíduos cooperativos e não cooperativos de acordo com diferentes variáveis independentes, assim como as comparações das escalas FIS e VENHAM entre os três tratamentos, foram avaliadas utilizando-se o teste de Qui-quadrado. Resultados: Quarenta e oito crianças e 120 dentes foram incluídos na análise. Dentre as variáveis analisadas, apenas o tempo de atendimento afetou significativamente o comportamento das crianças (p=0,018). No grupo RTTC ocorreram 15 casos de exposição pulpar (27,5%), enquanto que no grupo RPTC apenas 1 caso (2%). As taxas de sucesso clínicoradiográfico após RPTC e RTTC foram 92% e 98%, respectivamente (p=0,14). Foi observada uma tendência a menor taxa de sucesso clínicoradiográfico em cavidades oclusoproximais (92%) em comparação com cavidades oclusais (100%), porém não estatisticamente significante (p=0,08). Não houve diferença significativa entre os operadores. A taxa de sobrevida das restaurações foi de 66%, 85% e 92%, para os grupos RPTC, RTTC e pulpotomia, respectivamente, após 24 meses, (p=0,09). Quando a taxa de sobrevida das restaurações foi avaliada de acordo com o tratamento e o tipo de cavidade, foi observada taxa de sobrevida significativamente menor (p=0,007) para restaurações do tipo oclusoproximais após RPTC (52%).Por outro lado, os maiores percentuais 10 de sobrevida das restaurações foram observados em cavidades oclusais após RPTC (95%). A revisão de literatura demonstrou que o sucesso das restaurações aumenta quanto menor o número de superfícies envolvidas, assim, cavidades classe I apresentaram em torno de 90% de sucesso e diminui para 50% quando mais de uma superfície foi restaurada. Conclusões: As restaurações de resina composta sobre tecido cariado necessitam de proservação em curtos períodos de tempo para manutenção e reparo. / Partial caries removal in deep carious lesions of primary teeth has been demonstrated excellent clinical, radiographs and microbiological results. However, the clinical performance of composite resin restorations placed over the demineralized dentin need more information. The objective of this work was to investigate the restoration performance over carious tissue trough a literature systematic review and a randomized controlled clinical trial. Methods: Fifty-one children aged from 3 to 8 years old (28 boys and 23 girls) with, at least, one molar with deep carious lesion were included in this clinical trial. The teeth were randomly divided according to the following treatments: Control group - total caries removal (TCR); and Test - partial caries removal (PCR). In case of pulp exposure during dentinal excavation, pulpotomy was performed. Three Pediatric Dentist made the procedures that were followed-up by 3, 6, 12, 18 and 24 months. All procedures were performed under local anesthesia and rubber dam isolation. At the beginning and right after the procedure the children reported their anxiety through two scales: Venham Picture Test (VPT) and Facial Image Scale (FIS). The children behavior during the attendance was valued through Sarnat scale. During the time course follow-up clinical and radiographic aspects of the treatments were evaluated and the restorations analyzed by a calibrated and blinded examiner through modified USPHS. To determine the clinical and radiographic outcomes of composite restorations the groups were statistically analyzed using Kaplan-Meier survival followed by Log Rank. The distribution of cooperatives and non-cooperatives subjects in accordance with different independent variables as well as FIS and VENHAM comparisons between the tree treatments were availed using Qui-square test. Results: The final sample was comprised by forty-eight children and 120 teeth. Among all the analyzed variables, only the time spent for the procedure significantly affected the children behavior (p=0.018) The total caries removal procedure produced 15 pulp exposures (27.5%), while the same event occurred only in one case for the PCR group (2%). The clinical- radiographic success rate after PCR and TCR were 92% and 98%, respectively (p=0.14). It was observed a tendency to lower clinical-radiographic success rate in oclusoproximal cavities (92%) in comparison with oclusal (100%) but without statistic significance (p=0.08). The restorations survival rate was 66%, 85% and 92% to PCR, TCR and pulpotomy groups, respectively after 24 months follow-up (p=0.09). When the restorations survival rate was evaluated in accordance with type of treatment and the type of cavity was observed a significant lower survival rate (p=0.007) to oclusoproximal restoration after PCR (52%). On the other hand, the highest restorations survival was observed in oclusal cavities with partial caries removal (95%). The literature review shows that success rate increases with the decrease of involved surface at the restoration, thus class I restorations presented around 90% of success and it decreases below to 50% if more than one surface are restored. Conclusions: The composite resin restorations placed over caries tissue need shorter follow-up time to evaluate the necessity of being repaired or replaced.
167

Influência de diferentes métodos de condicionamento superficial em pinos pré-fabricados resinosos fibro-reforçados em vidro e quartzo na resistência adesiva a compósito de polimerização dual: teste de push-out / Influence of different pretreatments in glass and quartz fiber posts on the bond strength of a dual-cure resin core material: push-out test

Leandro Passos Soares 07 February 2012 (has links)
O objetivo deste estudo foi realizar uma avaliação tridimensional da rugosidade superficial em 3 tipos de pinos de fibra - DT LightPost, FRC Postec Plus e Transluma Post - submetidos a diferentes tratamentos de superfície e avaliar os efeitos dos pré-tratamentos na resistência adesiva a um compósito de presa dual Biscore. Os tratamentos de superfície foram: imersão em ácido hidrofluorídrico, jateamento com óxido de alumínio a 50m, imersão em peróxido de hidrogênio, jateamento com óxido de alumínio a 50m seguido de imersão em ácido hidrofluorídrico e jateamento com óxido de alumínio a 50m seguido de imersão em peróxido de hidrogênio. No experimento 1, 75 pinos foram divididos em 3 grupos (n = 25), de acordo com seu fabricante e subdivididos em cinco subgrupos. A rugosidade superficial foi medida usando um rugosímetro tridimensional e analisada com o software de análise 3D. Os valores de rugosidade foram obtidos antes e após diferentes tratamentos de superfície na área dos mesmos corpos-de-prova. Para o experimento 2, foram utilizados os mesmos corpos-de-prova, os mesmos grupos e subgrupos do experimento 1, tendo sido adicionado o subgrupo de controle (n=90) e a resistência adesiva a um compósito presa dual Biscore foi mensurada através de um teste push-out. A resistência adesiva foi medida em uma máquina universal de ensaios, com uma célula de carga tipo SLBL-5kN em uma velocidade de 0,5 mm / min. Os resultados do experimento 1 foram analisados através de um teste estatístico t-Student. Jateamento e jateamento seguido de imersão em ácido hidrofluorídrico produziram um aumento estatisticamente significante na rugosidade, contudo somente o tratamento por jateamento proporcionou um aumento significativo nos valores de rugosidade. Os resultados do experimento 2 foram obtidos através de um um teste t-unilateral de hipótese com variância desconhecida. Concluiu-se que o jateamento com óxido de alumínio a 50&#956;m em uma distância de 30 mm a 2,5 bar de pressão por 5 segundos foi suficiente para modificar a topografia dos pinos de fibra de vidro e quartzo e que o jateamento com partículas de 50 &#956; alumina a distância de 30 mm a 2,5 bar de pressão por 5 segundos foi o único tratamento de superfície que aumentou a resistência adesiva do compósito Biscore aos pinos DT Light Post e Transluma Post. Os pinos FRC Postec Plus não demostraram um aumento estatisticamente significante na resistência adesiva em nenhum grupo. / The aim of this study was to perform a tridimensional surface roughness test evaluation of different surface treatments to 3 types of fiber posts - DT LightPost, FRC Postec Plus e Transluma Post - and evaluate the effects of the different pretreatments on the bond strength of a dual-cure resin core material Biscore. The different surface treatments were: immersion in hydrofluoric acid, sandblasting abrasion with 50 alumina particles, immersion in hydrogen peroxide, sandblasting abrasion with 50 alumina particles followed by immersion in hydrofluoric acid and sandblasting abrasion with 50 alumina particles followed by immersion in hydrogen peroxide. In the first experiment seventy five fiber posts were divided into 3 groups (n = 25), according to their manufacturer and subdivided into 5 subgroups. Surface roughness was measured using a tridimensional surface roughness test and analyzed with 3D analysis software. Surface roughness was obtained before and after the different surface treatments at the same post area. In the second experiment the same samples divided in groups and subgroups were used, but a control group (no treatment) was added (n = 90) and the bond strength to a composite resin core material Biscore was measured using a push-out design. The interfacial push-out bond strength was measured in a universal testing machine, with a load cell type SLBL-5kN at a crosshead speed of 0.5 mm/min. Results in experiment 1 were statistically analyzed using Students t-Test. Sandblasting and sandblasting followed by immersion in hydrofluoric acid produced a significant increase in roughness, but the sandblasting treatment was able to provide a significant roughness increase. Results in experiment 2 were statistically analysed using one-sided t-Test of Hypothesis with unknown variance. It was concluded that sandblasting airborne-particle abrasion with alumina 50 at a distance of 30 mm at 2.5 bars pressure for 5 seconds was sufficient to modify the surface topography of glass and quartz fiber posts and the sandblasting abrasion with 50 alumina particles at a distance of 30 mm at 2.5 bars pressure for 5 seconds was the only surface treatment in DT Light Post and Transluma Post that increased the bond strength to dual cure resin composite cores. FRC Postec Plus post did not shown an increase in bond strength in any group.
168

Influência da fonte de luz fotoativadora nas propriedades ópticas de resína composta, em função da cor, espessura e tempo de armazenamento /

Queiroz, Renato Souza. January 2010 (has links)
Orientador: Sizenando de Toledo Porto Neto / Banca: Alberto Magno Gonçalvez / Banca: Sicknan Soares da Rocha / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: Esse estudo se propõe a avaliar as propriedades ópticas (Fluorescência e Absorbância) da resina composta fotoativada (4 SEASONS®) utilizando aparelho fotopolimerizador convencional (luz Halógena Ulttralux - DabiAtlant), e aparelho emissor de Diodo (Radii - SDI e Ultralume Led 5- Ultradent), em função da fonte de luz foto-ativadora, cor, espessura e tempo de armazenamento em saliva artificial. Foram confeccionadas 5 amostras (10,0x1,0 mm) para cada grupo experimental. Para a realização do teste de Absorbância foi utilizado aparelho espectrofotômetro de luz visível (Diode Array Spectrophotometer, HP - Serial Number: 8452-A). Para a obtenção dos valores de fluorescência emitida pelas amostras, foi utilizado espectrofotômetro (SPEX TRIAX FLUOROLOG 3, Jobin Yvon - Serial Number: 0135B-3-99). Os resultados foram julgados estatisticamente conforme a interação entre os fatores de avaliação nos distintos trabalhos. Pode-se concluir que a fonte de luz fotoativadora influenciou apenas a emissão fluorescente da resina de cor TC, não tendo efeito negativo na absorbância; o aumento na espessura da amostra acarretou uma diminuição na emissão fluorescente e na absorbância de todas as cores da resina, independente da fonte de luz; e as diferentes cores da resina exibiram diferentes emissões fluorescentes e absorbância... / Abstract: The arm of this study is to evaluate optical properties (fluorescence and Absorbance) of a composite resin (4 SEASONS®) using light curing units (LCUs)-(QTH - Ulttralux - DabiAtlant and LEDs Radii - SDI and Ultralume Led 5- Ultradent) in function of LCUs, shade, thickness and storage times. 5 samples were prepared for each experimental group. To perform the Absorbance test, was used of UV-Vis spectrophotometer (Diode Array Spectrophotometer, HP - Serial Number: 8452-A). To obtain the fluorescence emission by samples, we used a spectrophotometer (SPEX TRIAX FLUOROLOG 3, Jobin Yvon - Serial Number: 0135B-3-99). The results were deemed statistically as the interaction between the evaluation factors in the different works. It can be concluded that the LCUs only influenced the fluorescent emission of resin color TC, having no negative effect on the absorbance; the increase in thickness of the sample decrease the fluorescent emission and absorbance for colors of the resin, independent of the LCUs; different colors of resin exhibited different fluorescent emission and absorbance. / Doutor
169

Propriedades físicas e de adesão bacteriana de uma resina composta fotopolimerizável modificada com nanopartículas de prata

Neves, Patrícia Bolzan Agnelli das 24 November 2014 (has links)
Made available in DSpace on 2016-06-02T19:02:44Z (GMT). No. of bitstreams: 1 6426.pdf: 2868015 bytes, checksum: e3bf13cc85e7606dc2d0f7dbb387ebaa (MD5) Previous issue date: 2014-11-24 / Financiadora de Estudos e Projetos / The evaluation of new materials and biomaterials modified with silver nanoparticles is a line of research that has been gaining strength in various knowledge areas including dentistry. Even considering international scientific publications, however, there are still few studies evaluating dental restoration materials that are modified with silver nanoparticles. Proposal: this study aimed to compare a photopolymerizable composite resin modified with an antimicrobial silver nanoparticle additive (an experimental resin), with the photopolymerizable composite resin in its unmodified form (a commercially available dental restoration material), by evaluating the in vitro antibacterial properties and also some of the primary physical properties of the resin. Methodology: composite resin disks were made for three experimental groups: unmodified resin (control group) and modified resin with different silver nanoparticle concentrations: 0.3% and 0.6% wt (groups 1 and 2). The antibacterial activity on the surface of the samples was evaluated by in vitro growth of of Streptococcus mutans and Lactobacillus acidophilus biofilms in a 20% sucrose medium, which is followed by counting the viable cells from the biofilms through serial dilutions after three incubation periods - 1, 4 and 7 days (n = 9). Optical transmittance was tested to measure the percentage of transmittance in the samples (n = 9). The surface roughness was evaluated using Atomic Force Microscopy (n = 9). The colour of the samples and the colour difference between the groups was measured in a colorimetry test according to the CIELab system. The presence of silver in the nanoparticle additive was analysed using X-Ray Fluorescence Spectroscopy. The quality of the dispersion and distribution of silver on the samples was analysed using Transmission Microscopy. The liberation of silver in artificial saliva was also evaluated in vitro after three incubation periods (60, 120 and 210 days) with agitation of the samples, using the Inductively Coupled Plasma Optical Emission Spectroscopy technique. Results: for the three incubation times, the number of viable cells was statistically lower in groups 1 and 2 than in the control group (p < 0.05), and groups 1 and 2 were not statistically different (p > 0.05) for the two bacterial species (ANOVA Two way/Tukey). There was no significant difference in optical transmittance between group 1 and the control (p > 0.05), and group 2 had a lower transmittance value than the other groups (p < 0.05) (ANOVA/Tukey). The analysis of the values of the arithmetic roughness, which was obtained using the NanoScope software, showed that there was no significant difference in surface roughness between the three groups (p > 0.05) (ANOVA/Tukey). From the measurements of the colours, the total colour difference (&#916;E) between all of the groups was higher than 1 (the minimum value that represents a colour alteration perceptible to human vision) and lower than 3,3 (critical &#916;E). The presence of silver in the nanoparticle additive was confirmed in the X-Ray Fluorescence test. Microscopic analysis showed good distribution of silver for groups 1 and 2 (with silver in the four quadrants of the regions analysed). The dispersion was better for group 1 than for group 2 (which showed a higher number of particle clusters). After the three incubation times, silver was not detected in the artificial saliva for the three groups or; if it was present, the concentration was below the limit of detection for this technique (< 0.02 mg/L). Conclusions: the antibacterial property on the surfaces of the experimental resins was verified for the two cariogenic bacteria considered. Furthermore, the addition of silver did not cause negative alterations to the resin modified with the lower concentration of nanoparticles, which makes the continuation of this study possible and valuable. / A avaliação de novos materiais e biomateriais modificados com nanopartículas de prata é uma linha de pesquisa que vem ganhando força em várias áreas do conhecimento, inclusive na área odontológica. Porém, mesmo considerando a publicação científica internacional, ainda há poucas pesquisas que avaliam materiais restauradores dentários modificados desta forma. Proposição: o propósito deste estudo foi comparar a resina composta fotopolimerizável modificada com um aditivo antimicrobiano nanoparticulado de prata (uma resina experimental), com a resina composta fotopolimerizável em sua forma não modificada, um material restaurador dentário disponível comercialmente, avaliando a propriedade antibacteriana, in vitro, e também algumas de suas principais propriedades físicas. Metodologia: foram confeccionados discos de resina composta para 3 grupos experimentais: resina não modificada (grupo controle), e resina modificada com diferentes concentrações de nanopartículas de prata, 0,3 e 0,6% (grupos 1 e 2). A atividade antibacteriana na superfície das amostras foi avaliada pelo crescimento in vitro de biofilme de Streptococcus mutans e Lactobacillus acidophilus em meio de cultura contendo 20% de sacarose, seguido de contagem de células viáveis provenientes dos biofilmes após 3 períodos de incubação, 1, 4 e 7 dias, através de diluições seriadas (n=9). Um ensaio de transmitância óptica foi realizado para medir a porcentagem de transmitância das amostras (n=9). A rugosidade superficial foi avaliada por Microscopia de Força Atômica (n=9). A cor das amostras e a diferença de cor entre os grupos foi medida em um ensaio de colorimetria considerando o sistema CIELab. A presença de prata no aditivo nanoparticulado foi analisada por meio da Espectrometria de Fluorescência de Raios X. A qualidade da dispersão e distribuição da prata nas amostras foi analisada através da Microscopia de Transmissão. Foi também avaliada a liberação de prata em saliva artificial, in vitro, após 3 períodos de incubação das amostras, sob agitação, 60, 120 e 210 dias, através da técnica de Espectrometria de Emissão Óptica por Plasma Acoplado Indutivamente. Resultados: para os 3 tempos de incubação, o número de células viáveis foi estatisticamente mais baixo nos grupos 1 e 2 do que no grupo controle (p < 0,05), e os grupos 1 e 2 não mostraram entre si diferença estatisticamente significante (p > 0,05), para as 2 espécies bacterianas (ANOVA Two way/Tukey). Não houve diferença significante na transmitância óptica entre o grupo 1 e o controle (p > 0,05), já o grupo 2 apresentou um valor de transmitância menor que os demais grupos (p < 0,05) (ANOVA/Tukey). A análise dos valores de rugosidade aritmética, obtidos através do software NanoScope, mostrou que não houve diferença significante na rugosidade superficial entre os 3 grupos (p > 0,05) (ANOVA/Tukey). A partir das medições de cores, a diferença total de cor (&#916;E) entre todos os grupos foi superior a 1 (valor mínimo que representa uma alteração de cor perceptível à visão humana) e inferior a 3,3 (&#916;E crítico). A presença de prata no aditivo nanoparticulado foi confirmada no ensaio de Fluorescência de Raios X. A análise microscópica demonstrou boa distribuição de prata para o grupo 1 e 2 (com prata nos 4 quadrantes das regiões analisadas), e a dispersão foi melhor para o grupo 1 do que para o grupo 2 (que apresentou maior número de aglomerados de partículas). Após os 3 tempos de incubação, não foi detectada a presença de prata na saliva artificial, para os 3 grupos, sendo que, se presente, ela encontrava-se em uma concentração abaixo do limite de detecção da técnica (< 0,02 mg/L). Conclusões: a propriedade antibacteriana foi verificada nas superfícies das resinas experimentais para as duas espécies bacterianas cariogênicas consideradas, e a adição de prata não provocou alterações negativas na resina modificada com a menor concentração de nanopartículas, o que viabiliza a continuidade do estudo.
170

Influência de diferentes métodos de condicionamento superficial em pinos pré-fabricados resinosos fibro-reforçados em vidro e quartzo na resistência adesiva a compósito de polimerização dual: teste de push-out / Influence of different pretreatments in glass and quartz fiber posts on the bond strength of a dual-cure resin core material: push-out test

Leandro Passos Soares 07 February 2012 (has links)
O objetivo deste estudo foi realizar uma avaliação tridimensional da rugosidade superficial em 3 tipos de pinos de fibra - DT LightPost, FRC Postec Plus e Transluma Post - submetidos a diferentes tratamentos de superfície e avaliar os efeitos dos pré-tratamentos na resistência adesiva a um compósito de presa dual Biscore. Os tratamentos de superfície foram: imersão em ácido hidrofluorídrico, jateamento com óxido de alumínio a 50m, imersão em peróxido de hidrogênio, jateamento com óxido de alumínio a 50m seguido de imersão em ácido hidrofluorídrico e jateamento com óxido de alumínio a 50m seguido de imersão em peróxido de hidrogênio. No experimento 1, 75 pinos foram divididos em 3 grupos (n = 25), de acordo com seu fabricante e subdivididos em cinco subgrupos. A rugosidade superficial foi medida usando um rugosímetro tridimensional e analisada com o software de análise 3D. Os valores de rugosidade foram obtidos antes e após diferentes tratamentos de superfície na área dos mesmos corpos-de-prova. Para o experimento 2, foram utilizados os mesmos corpos-de-prova, os mesmos grupos e subgrupos do experimento 1, tendo sido adicionado o subgrupo de controle (n=90) e a resistência adesiva a um compósito presa dual Biscore foi mensurada através de um teste push-out. A resistência adesiva foi medida em uma máquina universal de ensaios, com uma célula de carga tipo SLBL-5kN em uma velocidade de 0,5 mm / min. Os resultados do experimento 1 foram analisados através de um teste estatístico t-Student. Jateamento e jateamento seguido de imersão em ácido hidrofluorídrico produziram um aumento estatisticamente significante na rugosidade, contudo somente o tratamento por jateamento proporcionou um aumento significativo nos valores de rugosidade. Os resultados do experimento 2 foram obtidos através de um um teste t-unilateral de hipótese com variância desconhecida. Concluiu-se que o jateamento com óxido de alumínio a 50&#956;m em uma distância de 30 mm a 2,5 bar de pressão por 5 segundos foi suficiente para modificar a topografia dos pinos de fibra de vidro e quartzo e que o jateamento com partículas de 50 &#956; alumina a distância de 30 mm a 2,5 bar de pressão por 5 segundos foi o único tratamento de superfície que aumentou a resistência adesiva do compósito Biscore aos pinos DT Light Post e Transluma Post. Os pinos FRC Postec Plus não demostraram um aumento estatisticamente significante na resistência adesiva em nenhum grupo. / The aim of this study was to perform a tridimensional surface roughness test evaluation of different surface treatments to 3 types of fiber posts - DT LightPost, FRC Postec Plus e Transluma Post - and evaluate the effects of the different pretreatments on the bond strength of a dual-cure resin core material Biscore. The different surface treatments were: immersion in hydrofluoric acid, sandblasting abrasion with 50 alumina particles, immersion in hydrogen peroxide, sandblasting abrasion with 50 alumina particles followed by immersion in hydrofluoric acid and sandblasting abrasion with 50 alumina particles followed by immersion in hydrogen peroxide. In the first experiment seventy five fiber posts were divided into 3 groups (n = 25), according to their manufacturer and subdivided into 5 subgroups. Surface roughness was measured using a tridimensional surface roughness test and analyzed with 3D analysis software. Surface roughness was obtained before and after the different surface treatments at the same post area. In the second experiment the same samples divided in groups and subgroups were used, but a control group (no treatment) was added (n = 90) and the bond strength to a composite resin core material Biscore was measured using a push-out design. The interfacial push-out bond strength was measured in a universal testing machine, with a load cell type SLBL-5kN at a crosshead speed of 0.5 mm/min. Results in experiment 1 were statistically analyzed using Students t-Test. Sandblasting and sandblasting followed by immersion in hydrofluoric acid produced a significant increase in roughness, but the sandblasting treatment was able to provide a significant roughness increase. Results in experiment 2 were statistically analysed using one-sided t-Test of Hypothesis with unknown variance. It was concluded that sandblasting airborne-particle abrasion with alumina 50 at a distance of 30 mm at 2.5 bars pressure for 5 seconds was sufficient to modify the surface topography of glass and quartz fiber posts and the sandblasting abrasion with 50 alumina particles at a distance of 30 mm at 2.5 bars pressure for 5 seconds was the only surface treatment in DT Light Post and Transluma Post that increased the bond strength to dual cure resin composite cores. FRC Postec Plus post did not shown an increase in bond strength in any group.

Page generated in 0.1074 seconds