• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Estudo dos fotoiniciadores utilizados em resinas compostas /

Alvim, Hugo Henriques. January 2008 (has links)
Orientador: José Roberto Cury Saad / Banca: Rodrigo de Castro Albuquerque / Banca: Walison Arthuso Vasconcellos / Banca: Maria Salete Machado Cândido / Banca: Osmir Batista de Oliveira Júnior / Resumo: O objetivo deste estudo foi avaliar as características de diferentes fotoinciadores com potencial para serem utilizados em resinas compostas. Foram utilizadas as resinas compostas: Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). Foram pesados 500mg de cada resina e dissolvidos em 1,0 ml de metanol. As amostras foram centrifugadas para acelerar a sedimentação das partículas inorgânicas. Foram pipetados 0,8 ml da solução sobrenadante e analisados por cromatografia gasosa acoplado ao espectrômetro de massa (GC-MS). Os resultados foram comparados a soluções de canforoquinona pura, utilizadas como padrão. O teste de T Student, (p=0,05), comparou os resultados entre as cores de cada marca comercial. Observou-se menor quantidade de canforoquinona na cor incisal da resina Filtek Z-250 (FZI) quando comparada à cor A3 (FZA3). Por outro lado, a resina Filtek Supreme apresentou quantidade de canforoquinona estatisticamente superior na cor Incisal. Na resina Pyramid Enamel foi encontrada canforoquinona apenas na cor A1, sendo que o fotoiniciador utilizado na cor Translucent não foi identificado. Baseado nos dados obtidos pode-se concluir que uma mesma marca comercial de resina composta pode apresentar diferenças na quantidade e no tipo de fotoiniciador utilizado. Em seguida investigamos a reação de polimerização de quatro compósitos experimentais por fotocalorimetria, utilizando diferentes fotoiniciadores. Esta técnica permite estimar o grau de conversão (GC) e parâmetros da cinética da reação como a aceleração da reação em tempo real. Foi elaborada uma resina composta experimental, a base de Bis-GMA (14,5% m/m), UDMA (6,5% m/m) e partículas de carga silanizadas (79% m/m). Este compósito foi dividido em quatro grupos, que receberam os seguintes fotoiniciadores:...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To identify and quantify the camphorquinone (CQ) used in different brands of composite resins as a function of the shade analyzed. Filtek Z250 A3 (FZA3), Filtek Z- 250 Incisal (FZI), Pyramid Enamel A1(PEA1), Pyramid Enamel Translucent (PET), Filtek Supreme A3E (FSA3) and Filtek Supreme GT (FSGT) were used. Five hundred milligrams of each resin were weighed and then dissolved in 1.0 ml of methanol. The samples were centrifuged to accelerate the sedimentation of the inorganic particles. 0.8 ml of the supernatant solution was collected with a pipette and assessed under gas chromatography coupled to the mass spectrometer (GC-MS). The results were compared to pure CQsolutions, used as a standard. Student's t-test, (p = 0.05) significant at the level of 5%, compared the results of each brand shade. A smaller amount of camphorquinone was found in Filtek Z-250 (FZI) resin incisal shade when compared to (FZA3) A3 shade. On the other hand, Filtek Supreme resin featured a statistically larger camphorquinone amount in the incisal shade. In Pyramid Enamel resin camphorquinone was found only in shade A1, while the photoinitiator used in the Translucent shade was not identified. Then we investigate the reaction of polymerization of four experimental composites by fotocalorimetria, using different photoinitiators. This technique allows estimating the degree of conversion (GC) and kinetic parameters of the reaction as the acceleration of the reaction in real time. It was drawn up a composite resin experimental, the basis of Bis-GMA (14.5% m / m), UDMA (6.5% m / m) and particulate load silanizadas (79% m / m). This composite was divided into four groups, which received the following fotoiniciadores: camphorquinone (CQ), 1-phenyl-1 ,2-propanodione (PPD), MAPO (Lucirin TPO) and BAPO (Irgacure 819). The reaction of polymerization of these four experimental composite was analyzed...(Complete abstract, click electronic access below) / Doutor
332

Avaliação da microdureza superficial da resina composta fotopolimerizada por aparelho de luz halógena e de diodo(LED) em função de opacidade e ação do flúor fosfato acidulado /

Firoozmand, Leily Macedo. January 2005 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Maria Amélia Máximo de Araújo / Banca: Maria Antonia Pereira / Banca: João Carlos da Rocha / Resumo: O objetivo deste trabalho foi verificar a influência da opacidade de cor, tipos de aparelhos fotopolimerizadores (luz halogena X led azul) e aplicação tópica do FFA 1,23% na microdureza da resina composta. A resina composta Esthet-X (Dentisply), nas cores A2 e A2-O foram inseridas em uma matriz de aço-inoxidável em cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halogena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 4 grupos com trinta amostras, sendo analisadas a superfície e a base das amostras. Estas foram armazenadas em água destilada, por 24h e posteriormente embutidas em RAAQ. Realizou-se a leitura da microdureza inicial em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. A seguir, foi aplicado o FFA 1,23% por 48 min e uma segunda leitura da microdureza foi realizada. O teste estatístico de ANOVA e Tukey (5%) demonstrou que a microdureza da superfície foi sempre maior que a da base. O aparelho de luz halógena apresentou maiores valores médios de microdureza da resina (57,61 HV) que o aparelho de LED (42,53 HV). Foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade, a resina A2-O apresentou os menores valores. A aplicação do FFA 1,23% promoveu menores valores de microdureza na resina. A opacidade da resina composta, o tipo e fonte polimerizadora, bem como a utilização tópica do FFA 1,23% influenciam no grau de microdureza resina. / Abstract: The aim of this study was to verify the influence of resin opacity, light curing units (halogen light X blue LED) and topic application of 1.23% acidulated phosphate fluoride (APF) on the resin hardness. The composite resin Esthet-X (Dentsply), shade A2 and A2-O was put in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a halogen light curing unit, XL 3000 (3M) or a blue LED unit, Optilight LD II (Gnatus), for 40s. Four groups with thirty samples were separated and the top and bottom of samples were analyzed. They were stored for 24h and afterwords, built-in acrylic resin. Vickers hardness measurements were made in Vickers Digital Microhardmeter, using 50g load and 30s time. The APF 1.23% was applied for 48 min and a second hardness measurement was done. Statistic test ANOVA and Tukey (5%) demonstrated that top hardness were always higher than bottom. The halogen unit presented higher hardness values (57.61 HV) than LED unit (42.53 HV). Significant differences were found between the hardness values when the opacity was varied, and depth wise the A2-O resin presented the lowest values. The use of 1.23% APF on the resin resulted in the lowest values of hardness. The resin opacity, the light curing unit and the use of 1.23% APF have all influence on the resin hardness. / Mestre
333

Avaliação clínica e radiográfica de restaurações com resina bulk fill e cimento de ionômero de vidro modificado por resina: estudo comparativo em cavidades classe II de molares decíduos

Silva, Renata Maria de Oliveira 24 February 2017 (has links)
Objetivo: avaliar o desempenho clínico e radiográfico da resina bulk fill em cavidades classe II em molares decíduos em comparação ao cimento de lonômero de vidro modificado por resina Metodologia: Estudo clínico em que participaram 16 crianças entre 4 a 7 anos de idade, apresentando, lesões de cárie nas superfícies oclusal e/ proximal sem sinal ou sintomatologia de pulpite irreversível. Foram restaurados 39 dentes sendo 21 com cimento de ionômero de vidro modificado por resina (CIVMR) e 18 com resina bulk fill (RBF).Os materiais foram alocados a cada dente por sorteio e as restaurações executadas pelo mesmo operador. A avaliação clínica foi realizada, imediatamente, e após um e seis meses de acordo com os critérios United States Public Health Service - USPHS (retenção, coloração, adaptação marginal, coloração marginal, cárie secundária, textura superficial e forma anatômica). Radiográfica foram obtidas imediatamente e após seis meses. Para a análise estatística o teste U de Mann Whitney foi aplicado. Resultados: Ambos materiais apresentaram baixo índice pelos critérios de falhas clínicas ou radiográficas, porém diferença significante foi encontrada para a forma anatômica (0,0146), sendo a RBF o material de melhor desempenho neste critério. Conclusão: Os dois materiais apresentaram desempenho satisfatório, para restaurações classe II em molares decíduos no período de seis meses, porém, para o critério forma anatômica a RBF apresentou desempenho superior. / Objective: The aim of the study was to assess the clinical and radiographic performance of bulk fill resin when used as Class II restorations in primary molars compared to resin-modified glass ionomer cement Methodology: A total of 16 children, aged 4-7 years old, having caries on the occlusal and/proximal surfaces without signs and/or symptoms of irreversible pulpits were selected. It was placed 39 restorations in primary molars, 21 were of (RMGIC). randomly allocated for a each tooth am the restoration performed by one trained operator and 18 of bulk fill resin (BFR). The materials and the teeth were selected by lottery and done by the same operator. The restorations were evaluated clinically at baseline and after 1 and 6 months following the criteria of United States Public Health Service - USPHS (retention, color, marginal adaptation, marginal discoloration, tooth secondary, surface texture and anatomical form) X-ray images were taken at baseline and after 6 months. For the statistical analysis was perfomed using the Mann-Whitney U test (X = 0,05). Results: Both materials showed few failures of clinical and radiographic evaluations, however significant difference was found for the anatomical form (0.0146), being the BFR the material of better performance for this criterion. Conclusion: Both materials presented satisfactory performance, at 6 months for Class II restoring in primary molars, however for anatomical form the BFR showed better performance. / Dissertação (Mestrado)
334

Comparação in vitro de parâmetros para fotoativação de restaurações em resina composta por meio de microdureza e microscopia eletrônica de varredura / In vitro comparison of parameters for photoactivation of composite resin restorations using hardness and scanning electron microscopy

Carlos Alberto Kenji Shimokawa 13 September 2013 (has links)
Este estudo in vitro teve como objetivo a comparação de diferentes protocolos para fotoativação de restaurações em resina composta por meio de teste de microdureza e análise da adaptação marginal com microscopia eletrônica de varredura. Foram confeccionadas restaurações de 2mmx4mmx2mm com a resina composta Premisa (Kerr) em 30 dentes bovinos. Durante o procedimento restaurador, o método de fotoativação teve variação, sendo um grupo ativado com o método contínuo (grupo controle) durante 20 segundos, utilizando o fotoativador Elipar Freelight 2; outro grupo utilizou o mesmo equipamento fotoativador, com variação da distância da ponta ativadora, a fim da promoção de um método soft-start (grupo soft-start), tendo distância inicial de 6mm por 20 segundos, seguido de distância mínima por mais 10 segundos; e um terceiro grupo utilizou a tecnologia PLS (grupo DEMI), fornecida pelo equipamento DEMI, que fornece uma luz pulsada e permite a polimerização adequada de uma resina composta em 5 segundos (segundo o fabricante). Após 24 horas de restaurados, mantidos em estufa a 37ºC, os dentes foram seccionados no sentido inciso cervical resultando em 60 corpos de prova, sendo metade deles utilizados em cada teste (N=10). As metades tiveram as superfícies correspondentes ao corte transversal lixadas até a obtenção de superfícies planas e polidas, sendo que 30 delas foram selecionadas aleatoriamente para o teste de microdureza Knoop em 3 diferentes profundidades e as outras 30 metades foram replicadas em resina epóxica para leitura em microscopia eletrônica de varredura. Com as imagens obtidas foram feitas medidas de porcentagem de perímetro de restauração com desadaptação marginal e largura da maior fenda encontrada. Foram aplicados testes estatísticos de análise de variância split plot para os resultados de dureza e one way para a adaptação marginal. Em relação à dureza, os testes mostraram não haver diferença estatisticamente significante entre os grupos avaliados, enquanto houve diferença nas diferentes profundidades (p<0,0001), sendo a dureza na região profunda maior do que na média, que foi maior do que na superficial. Para a adaptação marginal, os testes não mostraram diferença estatisticamente significante para a largura de maior fenda encontrada entre os grupos controle e DEMI, somente o grupo soft-start foi diferente dos outros grupos (p=0,0064), tendo ele os menores valores. Apesar de a porcentagem de perímetro com desadaptação marginal ter apresentado valores com grandes valores de desvio padrão, foi encontrada diferença estatisticamente significante entre os grupos controle e DEMI, mas não entre os grupos DEMI e soft-start. O teste de correlação de Pearson demonstrou correlação linear positiva entre largura da maior fenda encontrada e porcentagem de perímetro com desadaptação marginal. Foi possível a conclusão de que o protocolo de fotoativação soft-start melhorou a adaptação marginal das restaurações em resina composta, sem alterar a dureza do material; o equipamento fotoativador DEMI, com a utilização da tecnologia PLS, teve resultados sem diferença estatisticamente significante na avaliação da adaptação marginal, quando comparados ao grupo controle; nenhum dos protocolos de fotoativação testados causou alteração na dureza da resina composta fotoativada, quando comparadas entre si, havendo aumento dessa propriedade conforme houve aumento da profundidade. / This in vitro study aimed to compare different protocols for the photoactivation of composite resin restorations using microhardness test and analysis of marginal adaptation with scanning electron microscopy. Restorations with 2mmx4mmx2mm were made in 30 bovine teeth using the composite resin Premisa (Kerr). During the restorative procedure, the polymerization method had change, being one group activated with the continuous method (control group) for 20 seconds using the curing unit Elipar Freelight 2, another group used the same curing unit equipment, varying the distance from the activator tip in order to promote a soft-start method (soft-start group), with initial distance of 6mm for 20 seconds, followed by minimum distance for 10 seconds, and a third group used technology PLS (DEMI group) supplied from the DEMI, which provides a pulsed light and allows an adequate polymerization of a resin composite in 5 seconds (according to manufacturer). 24 hours after restoration, maintained at 37 ° C, the teeth were sectioned incisocervical towards resulting in 60 specimens, half of them being used in each test (N = 10). The halves were sanded on the transversal section surfaces to obtain flat and polished surfaces, of which 30 were randomly selected for Knoop microhardness testing in 3 different depths and the other 30 halves were replicated in epoxy resin for microscopy scanning electron reading. Measures of percentage of perimeter with marginal desadaptation and width of the largest slot found were made with the obtained images. Split plot analysis of variance tests were applied to hardness results and one way to the marginal adaptation. Regarding the hardness, tests showed no statistically significant difference among the groups, while there were differences at different depths (p<0,0001), being the hardness of the deep region highest than the medium, which was higher than the superficial. For marginal adaptation, tests showed no statistically significant difference for the width of the largest slot found between the control group and DEMI, only the soft-start group was different from the other groups (p=0,0064), having the lowest values. Despite the large standard deviations shown by the percentage of perimeter with marginal desadaptation, statistically significant difference was found between the control and DEMI, but not between groups DEMI and soft-start. The Pearson correlation test showed positive linear correlation between the width of the largest slot found and the percentage of perimeter with marginal desadaptation. It was possible to conclude that the soft-start photoactivation protocol improved the marginal adaptation of composite resin restorations, without changing the hardness of the material; DEMI curing unit equipment, using PLS technology, showed no statistically significant difference in the evaluation of marginal adaptation, comparing with the control group; none of the protocols tested photoactivation caused change in hardness of composite resin when compared to each other, with an increase of this property as the depth increased.
335

"Efeitos de bebidas com baixo pH e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas" / Effect of acidic beverages and toothbrushing upon restorative materials used in noncarious cervical lesion

Sheila Regina Maia Braga 07 June 2005 (has links)
O presente estudo analisou in vitro o efeito de bebidas com baixo pH (suco de laranja, Coca-Cola e uísque) e da escovação dental simulada sobre os materiais restauradores utilizados em lesões cervicais não cariosas: resina composta microhíbrida Filtek Z250/3M, resina composta de micropartículas Durafill VS/Heraeus Kulzer, resina composta flow Natural Flow/DFL, compômero Dyract AP/Dentsply, cimento de ionômero de vidro resino-modificado Vitremer/3M. Os materiais foram avaliados quanto à alteração de peso e rugosidade superficial, em balança analítica e em rugosímetro, respectivamente. Foram confeccionados vinte corpos-de-prova de 10 mm de diâmetro e 4 mm de espessura, de cada material. Cinco corpos-de-prova de cada material foram imersos nas bebidas testadas, por 10 dias a 37 °C, com trocas diárias das bebidas. A água destilada foi utilizada como controle. Após a imersão, os corpos-de-prova foram submetidos a 20.000 ciclos de escovação, utilizando escovas de cerdas macias e solução creme dental/água destilada na proporção 1:2. A alteração de peso foi determinada pela porcentagem correspondente à diferença de peso inicial e total (após erosão + escovação). A alteração da rugosidade superficial foi determinada pela diferença entre a rugosidade inicial e total (após erosão + escovação). Os resultados obtidos foram submetidos à análise de ANOVA e Tukey com p<0,05. A imersão em suco de laranja e Coca-Cola, seguida pela escovação, causou maior alteração de peso, estatisticamente significante para o Dyract (-2,55%/-1,72%) e para o Vitremer (-5,03%/-2,42%) comparados às RC Z250 (0,33%/0,20%), Durafill (0,17%/-0,18%) e Natural Flow (-0,14%/-0,17%).O CIVRM Vitremer apresentou as maiores alterações de rugosidade superficial (2,96 mm/1,59 mm) após imersão em suco de laranja e Coca-Cola, seguida de escovação. Houve correlação entre alteração de peso e rugosidade superficial / This study evaluated in vitro the effect of acidic beverages (orange juice, Coca-Cola soft drink, whisky) and toothbrushing upon restorative materials used in noncarious cervical lesions: one hybrid composite (Filtek Z250/3M), one microfill composite (Durafill VS/Heraeus Kulzer), one flow composite (Natural Flow/DFL), one compomer (Dyract/Dentsply) and one resin-modified glass ionomer (Vitremer/3M). Twenty standardized cylindrical specimens (10 mm in diameter and 4 mm thickness) of each material was made. In this research, measures of the changes in weight and roughness surface were carried out using a analytical scale and a rugosimeter, respectively. Five specimens of each material were immersed in test solutions for a 10-day period at a temperature of 37 °C. Distilled water was used like a control. After erosion, the specimens were submitted to 20,000 strokes of toothbrus hing using soft bristles tips and a slurry contained a 1:2 mixture of toothpaste and distilled water. The changes of weight was calculated by percentage corresponded of difference between initial and total weights (before and after erosion + toothbrusing). The changes of roughness was determined by difference between initial and total roughness (before and after erosion + toothbrushing). The data were analyzed using analysis of variance (ANOVA) and Tukey Test at level of p<0.05. The immersion in orange juice and Coca-Cola followed by toothbrushing caused higher changes of weight, statistically significant, for Dyract (-2.55%/-1.72%) and Vitremer (-5.03%/-2.42%) compared to Z250 (0.33%/0.20%), Durafill (0.17%/-0.18%) and Natural Flow (-0.14%/-0.17%). Vitremer presented the highest changes of surface roughness (2.96 mm/1.59 mm) after immersion in orange juice and Coca-Cola followed by toothbrushing. There was correlation between changes of weight and roughness.
336

Formação de fendas em restaurações de composito : tecnicas de avaliação, efeito de metodos de fotoavaliação e relação com a resistencia da união / Gap formation in composite restorations : evaluation techniques, effect of photoactivation methods and relantionship with bond strength

Alonso, Roberta Caroline Bruschi 22 February 2007 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T10:42:08Z (GMT). No. of bitstreams: 1 Alonso_RobertaCarolineBruschi_D.pdf: 2828251 bytes, checksum: 644a34bfa8b27efb0da35a9b5d7f13de (MD5) Previous issue date: 2007 / Resumo: A formação de fendas em restaurações de compósito foi caracterizada neste estudo, abrangendo-se técnicas de avaliação, fatores modificadores e a relação com a resistência de união das restaurações à estrutura dental. No capítulo 1, objetivou-se validar a técnica do corante para avaliação das fendas através da comparação com a observação em Microscopia Eletrõnica de Varredura (MEV). Vinte incisivos bovinos foram selecionados e desgastados até expor uma área plana em dentina, onde duas cavidades foram preparadas e restauradas com o compósito Filtek 2250 ou Filtek Flow. As amostras foram polidas e réplicas foram obtidas em resina epóxica. As réplicas foram observadas em MEV para determinar a porcentagem de fenda ao longo da margem cavitária. Na técnica do corante, Caries Detector (Kuraray) foi aplicado sobre as restaurações durante 5s. A imagem digital das restaurações coradas foi analisada com o software Image Tool para determinar a porcentagem de fendas. Os dados foram submetidos a ANOVA e teste de correlação de Pearson. Filtek Flow apresentou 35,54% e 33,52%, e Filtek 2250 26,68% e 29,11% de fendas, quando avaliadas em MEV e pela técnica do corante, respectivamente. Não houve diferença significativa entre os compósitos independente do método de avaliação, havendo forte correlação positiva (r=0,83) entre eles. Concluiu-se que a técnica do corante pode ser utilizada para avaliação das fendas com confiabilidade dos resultados. No capítulo 2, o efeito de métodos de fotoativação modulados na' adaptação marginal e intema de restaurações confeccionadas com diferentes compósitos foi determinado. Sessenta terceiros molares foram selecionados, seccionados (2 fragmentos) e tiveram a superfície vestibular ou palatina ou lingual desgastada para expor uma área plana em esmalte, onde uma cavidade foi confeccionada. Os dentes foram distribuídos em 12 grupos (n=lO), segundo o compósito restaurador (Filtek 2250, Herculite XRV e Heliomolar) e o método de foto ativação (Luz continua; Soft-Start; Pulse delay; Luz intermitente). O teste de adaptação marginal (técnica do corante) foi conduzido da mesma maneira descrita anterionnente. Após, os espécimes foram seccionados dividindo a restauração em 4 fatias, que foram coradas e o mesmo procedimento de avaliação da adaptação marginal foi realizado para determinar a adaptação intema. Assim, põde-se observar que todas as restaurações apresentaram perfeito selamento das margens extemas. Considerando as fendas intemas, os métodos modulados geraram redução significativa nas fendas quando comparados à luz contínua, independe do compósito empregado. Filtek 2250 apresentou a melhor adaptação interna, independente do método de fotoativação. A interação tipo de compósito e método de fotoativação não foi significativa. Conclui-se que os métodos de fotoativação modulados são eficientes na redução da formação de fendas internas e que podem ser indicados para a prática clínica, independente do compósito empregado. No capítulo 3, o objetivo foi relacionar a resistência da união à adaptação marginal e interna de restaurações fotoativadas por diferentes métodos. A resistência da união foi mensurada em cavidades tronco-conicas confeccionadas em dentes bovinos através do teste push-out (Instron). A adaptação marginal e interna das restaurações foi verificada da mesma maneira descrita anteriormente. Em ambos os testes, as cavidades foram restauradas com o compósito Esthet-X, sendo as amostras distribuídas em 5 grupos (n=10), de acordo com o método de fotoativação: G 1 - Luz contínua; G2 - Luz contínua baixa intensipade; G3 - Soft-start; G4 - Luz Intermitente; G5 - Pulse Delay. A dose de energia foi padronizada em 14J. Os dados foram submetidos a ANOVA e teste de Tukey. Considerando resistência da únião, G5 (7,2 MPa) apresentou resultados significativamente melhores que G 1 (4,6 MPa). G2, G3 e G4 tiveram médias intermediárias, não havendo diferenças significativas entre esses grupos e entre eles e G 1 ou G5. Considerando adaptação marginal, não houve diferença significativa entre os grupos. Na adaptação interna (que incluía o substrato dentinário), o resultado foi inverso ao do teste de resistência de união, ou seja, G5 (2,8%) teve menor média de fendas que G 1 (10,1%). Concluiu-se que a modulação da energia luminosa pode acarretar em aumento da resistência da união e redução na formação de fendas internas, havendo relação inversa entre resistência da união e formação de fendas internas / Abstract: Gap formation in composite restorations has been characterized in this dissertation by way of evaluation techniques, modifying factors and the relationship between bond strength of the restorations and the dental structure. In Chapter 1 the objective was to compare the dye staining technique to Scanning Electron Microscopy (SEM) evaluation of gap formation in order to validate the dye technique. Twenty bovine incisors were selected and ground so as to expose a flat dentin area in which two circular cavities were prepared and restored using Filtek 2250 or Filtek Flow. The specimens were polished and replicas were obtained in epoxy resin. Replicas were observed in SEM to determine the percentage of gap fonnation in the margins of the restorations. In dye staining technique, the Caries Detector was applied on each restoration for 5 seconds. Digital images of the stained restorations were analyzed using Image Tool to determine gap percentage. Data were submitted to ANOVA and Pearson's correlation. Filtek Flow showed 35.54% and 33.52% of gap and Filtek 2250 showed 26.68% and 29.11%, when evaluated using SEM and Dye staining technique, respectively. There was no difference between the composites, regardless of the evaluation technique. There was a strong positive correlation (r=0.83) between the results obtained through the tested methods to assess marginal gap. This led to the conclusion that dye staining technique can be reliably employed to evaluate the gap fonnation in composite restorations. Chapter 2 aims at determining the effect of modulated photoactivation methods on gap fonnation of restorations using different composites. Sixty third molars were selected, sectioned (2 fragments) and ground so as to expose a flat enamel area in which a cavity was prepared. The specimens were distributed into twelve groups (n=10), according to the restorative composite (Filtek 2250, Herculite XRV, and Heliomolar) and the photoactivation method (Continuous Light, Soft-Start, Pulse Delay, and Intermittent Light) applied. Marginal adaptation test was conducted in the same way described before (dye staining technique). The specimens were then sectioned in 4 slices, all of which were stained, and the same evaluation procedure used to determine marginal adaptation was employed to evaluate internal gap fonnation. All restorations showed perfect sealing of the enamel outer margins. With regards to internal adaptation, modulated photoactivation methods showed a significant reduction on gap fonnation when compared under continuous light, regardless of the composite. Filtek 2250 showed the best internal adaptation, regardless of the photoactivation method. The interaction between restorative composite and photoactivation method was not significant. The conclusion was that modulated photoactivation methods decrease the internal gap formation of composite restorations and should thus be encouraged on clínical practice, regardless of the type of composite. In Chapter 3, the aim was to evaluate the relationship between bond strength and marginal and internal adaptation of composite restorations photocured by different methods. Bond strength was measured in conical cavities prepared in bovine incisors using push-out test (Instron). Marginal and internal adaptation testswere conducted in the same way as before (dye staining technique). For both tests, cavities were filled with Esthet X resin composite. The specimens were distributed into 5 groups (n= 1 O) according to photoactivation method: G 1 - continuous light; G2 low intensity continuous light; G3 - soft start; G4 - intermittent light; G5 - pulse delay. 14J was the standard energy dose. Data were submitted to ANOVA and Tukey's test. Regarding bond strength, G5 (7.2 MPa) was statistically superior to Gl (4.6 MPa). G2, G3 and G4 showed intermediate mean values, which were not different from each other or from G 1 or G5. Regarding marginal adaptation, there was no statistical difference among the groups. Internal adaptation results (that included dentin substrate) were the opposite of bond strength results. G5 (2.8%) showed a reduction on gap formation when compared to Gl (10.1%). In conclusion, it may be said that the modulated photocuring methods can increase bond strength while decreasing internal gap formation. An opposite relationship was observed regarding push-out bond strength and internal adaptation of composite restorations / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
337

Desgaste abrasivo de uma resina composta, através de três diferentes métodos (disco retificado, escovação e nanodurômetro) / Abrasive wear of a composite resin, using three different methods (ground disc, toothbrushing and nanodurometer)

Márcia Furtado Antunes de Freitas 16 September 2011 (has links)
Neste estudo, foi avaliada a resistência ao desgaste abrasivo de uma resina composta, através de três diferentes métodos: do disco retificado, por escovação e do nanodurômetro. Nos dois primeiros métodos, foram utilizados 20 espécimes da resina Filtek Z250 (10 da cor Incisal e 10 da cor C4, ambos fotopolimerizados por 30 segundos cada) e 10 de polimetilmetacrilato (PMMA), atuando estes últimos como padrão de referência. Para os ensaios com o nanodurômetro, foi utilizado apenas um espécime de cada cor, assim como um único de PMMA, em cujas superfícies planas foram efetuadas sete medições, o que foi considerado equivalente a sete espécimes. No método do disco retificado, cada espécime de resina composta era confeccionado diretamente numa cavidade semicircular, localizada na periferia de um disco-suporte; os espécimes de PMMA consistiam em discos constituídos exclusivamente por este material; o desgaste de cada espécime era promovido por um disco de porcelana e seu conseqüente deslocamento era detectado por um palpador; assim, a taxa de desgaste era estabelecida, expressa em milímetros cúbicos por newton por segundo (mm3/N.s). No método de escovação, cada espécime cilíndrico ficava preso numa placa metálica, a qual era fixada no interior da máquina de escovação; sua perda de massa (em miligramas) era verificada através de uma balança analítica. No método do nanodurômetro, existiu apenas um espécime ci líndrico para cada condição, em cuja face plana superior eram feitos sete sulcos (equivalentes a sete espécimes); o coeficiente de atrito permitia estabelecer a respectiva resistência ao desgaste. Para cada método utilizado, os dados foram tratados estatisticamente, através de análise de variância (ANOVA) e de teste de Tukey. Pôde-se concluir que, através do disco retificado, a taxa de desgaste (em mm3/N.s) dos materiais foi: Incisal (0,6807) > C4 (0,5012) > PMMA (0,1439); que, através da escovação, a taxa de desgaste (em mg) foi de 5,40 para Incisal, de 9,35 para C4 e de 5,88 para PMMA, sem diferença significante apenas entre Incisal e PMMA, os mais resistentes; e que, através do nanodurômtero, a resistência ao desgaste abrasivo (expressa pelo coeficiente de atrito) foi de 0,207 para Incisal, de 0,214 para C4 e de 0,281 para PMMA, sem diferença significante agora apenas entre Incisal e C4, os menos resistentes. / Abrasive wear of a composite resin, using three different methods (ground disc, toothbrushing and nanodurometer). The aim at this study was to evaluate the resistance to abrasive wear of a composite resin, using three different methods: ground disc, toothbrushing and nanodurometer. At the first two methods were employed 20 specimens of Filtek Z250 composite resin (10 of Incisal and 10 of C4, both the colors cured for 30 seconds each one) and 10 of polymethylmethacrylate (PMMA), the latter acting as a reference standard. For the tests with the nanodurometer it was used only one specimen of each color, as well as just one of PMMA, in whose flat surfaces seven measurements were made, what was considered equivalent to seven specimens. At the ground disc method, each composite resin specimen was directly made on a semicircular cavity located on the periphery of a supporting disc; PMMA specimens consisted of discs made up exclusively with this material; the wear of each specimen was promoted by a ceramic disc and its consequent displacement was detected by a sensor; thus, the wear rate was established, expressed in cubic millimeters per newton per second (mm3/N.s). At the toothbrushing method, each cylindrical specimen was trapped in a metal plate, which was fixed inside the machine brushing; its weight loss (in milligrams) was verified by an analytical balance. At the nanodurometer method, there was only one cylindrical specimen for each condition, in whose flat upper face seven grooves were made (what was equivalent to seven specimens); the coefficient of friction was used to establish its wear resistance. For each method, data were statistically analyzed by ANOVA and Tukey\'s test. It could be concluded that, by ground disc method, materials wear rate (in mm3/N.s) was Incisal (0.6807) > C4 (0.5012) > PMMA (0.1439); by brushing method, materials wear rate (in mg) was 5.40 for Incisal, 9.35 for C4 and 5.88 for PMMA, without significant difference only between Incisal and PMMA (the toughest); by nanodurometer method, abrasive wear resistance (expressed by the coefficient of friction) was 0.207 for Incisal, 0.214 for C4 and 0.281 for PMMA, now without significant difference just between Incisal and C4, the least resistant.
338

Avaliação in vitro do efeito da aplicação de carregamento oclusal na qualidade marginal de restaurações cervicais em cavidades em forma de cunha / In viitro evaluation of the effects of occlusal loading on the marginal quality of cervical tooth restoration for wedge-shaped cavities

Luciana Fávaro Francisconi 27 November 2008 (has links)
A abfração, uma das causas das lesões cervicais não cariosas, caracteriza-se pela perda de tecido mineralizado, em forma de cunha, próxima à junção cementoesmalte. Hipoteticamente, é o resultado de forças oclusais excêntricas aplicadas sobre os dentes. Essas lesões são freqüentemente restauradas para impedir sua progressão, para proteger e aumentar a resistência do remanescente dental, reduzir a hiperestesia dentinária e manter a saúde periodontal. Entretanto, pouco se sabe quanto ao efeito dos fatores causadores da abfração na qualidade marginal de restaurações cervicais, quando da reabilitação dessas lesões. Este estudo in vitro propõe-se, portanto, a analisar o efeito da aplicação de carga oclusal na qualidade marginal de restaurações de cavidades cervicais em forma de cunha, utilizando microscopia confocal de varredura a laser. Para tal, foram utilizados 40 dentes prémolares superiores humanos hígidos, extraídos, nos quais foram preparadas cavidades padronizadas em forma de cunha, em sua região cervical vestibular, por meio da utilização de pontas diamantadas cilíndricas de topo plano nº 3100 (1,6 mm de diâmetro e 21 mm de comprimento), posicionadas em 45º com a superfície mais plana e próxima à junção amelo-cementária. As cavidades (1,3 mm de profundidade, 2,3 mm de abertura ocluso-cervical, 4,0 mm de abertura mésio-distal, 1,6 mm de extensão na parede oclusal e 1,9 mm de extensão na parede cervical) foram restauradas com resina composta (Z250®) em associação ao uso de um sistema adesivo (Single Bond®). Para possibilitar a análise ao microscópio confocal, o sistema adesivo foi marcado previamente com adição de rodamina B. Após imersão em água deionizada, por 7 dias e polimento das restaurações, os espécimes foram incluídos em uma matriz de resina acrílica. A porção radicular de cada dente foi revestida com uma camada de poliéter (Impregum®), de aproximadamente 1 mm, a fim de simular o ligamento periodontal. A porção coronária foi mantida totalmente exposta ao meio externo. Os dentes foram, então, submetidos à ciclagem mecânica, pela ação de uma ponta metálica em forma de torpedo, exercendo carga de 150 N, num total de 106 ciclos. Para tanto, a ponta foi posicionada de acordo com as seguintes condições experimentais: sobre a vertente triturante interna da cúspide vestibular (GI; n=10); sobre o sulco central (GII; n=10); e sobre a vertente triturante interna da cúspide lingual (GIII; n=10). O grupo controle (GIV; n=10) não foi submetido à ciclagem mecânica, permanecendo apenas armazenado em água deionizada, a 37ºC, durante todo o período experimental. Finalizada a ciclagem mecânica, as superfícies vestibulares dentárias foram, então, recobertas com duas camadas do sistema adesivo (Single Bond®), agora marcado com fluoresceína, para delimitação dos possíveis defeitos formados. Os dentes foram seccionados longitudinalmente em duas metades (mesial e distal) e submetidos à avaliação em microscopia confocal, para análise da qualidade da margem das restaurações. Foi aplicado o teste do qui-quadrado (p<0,05) para as variáveis qualitativas presença ou ausência de fendas marginais e localização das fendas em relação às paredes cavitárias (oclusal, cervical ou ambas). Para as variáveis quantitativas (amplitude e extensão das fendas) aplicou-se o teste de Kruskal-Wallis (p<0,05). Os espécimes submetidos ao carregamento oclusal, independentemente do local de aplicação da força, apresentaram maior porcentagem de fendas marginais (53,33%) quando comparados aos espécimes do grupo controle (10%; p=0,016). Não houve diferença estatisticamente significante entre o local de aplicação de força oclusal tanto para a presença ou ausência de fendas marginais (p=0,875); como para a localização das fendas em relação às paredes cavitárias (p=0,270) ou mesmo para a extensão (p=0,190) e amplitude das mesmas (p=0,070). Conclui-se, portanto, que a aplicação de carga oclusal prejudicou o comportamento marginal de restaurações cervicais, mas a variação do local de incidência de carga não interferiu no comportamento marginal das mesmas. / Tooth abfraction, one of the causes of non carious cervical lesions, is a wedgeshaped tissue loss, situated next to the cement-enamel junction, being, hypothetically, the result of eccentric occlusal loads applied to the teeth. These lesions are often restored to avoid their progression, to protect and increase remnant tooth resistance, to reduce dental hypersensitivity and to maintain periodontal health. However, there is little knowledge about the effect of abfraction etiology factors on the restoration marginal quality in the rehabilitation of these lesions. This in vitro study intends, therefore, to analyze the effect of the application of occlusal load on the marginal quality of cervical restorations in wedge-shaped cavities, by employing laser scanning confocal microscopy. Standardized wedge-shaped cavities were prepared in the cervical buccal region of 40 sound extracted upper human premolars, by the use of a cylindrical diamond bur #3100 (1.6 mm in diameter and 21 mm in length), positioned in 45º with the surface that is plainer and closer to the cementenamel junction. The cavities (1.3 mm in depth, 2.3 mm in occluso-cervical opening, 4.0 mm in mesio-distal opening, 1.6 mm in occlusal wall length and 1.9 mm in cervical wall length) were filled with a composite resin (Z250®) associated with the use of an adhesive system (Single Bond®). For the analysis at the confocal microscope to be possible, the adhesive system was previously modified by the addition of rodhamine B. After storage in deionized water for 7 days, and after the finishing and polishing of the restorations, specimens were included in acrylic resin matrixes. The radicular portion of each tooth was covered by an approximately 1 mm layer of a polyether (Impregum®), for the creation of an artificial periodontal ligament. The crown portion was kept totally exposed to the external environment. Teeth were, then, submitted to the mechanical cycling, by the action of a torpedo-shaped tip that exerted a 150 N load for a total of 106 cycles. The tip was positioned according to the following experimental conditions: over the internal triturant vertent of the buccal cusp GI; n=10); over the centre of the fissure (GII; n=10); and over the internal triturant vertent of the lingual cusp (GIII; n=10). The control group (GIV; n=10) was not submitted to the mechanical cycling, staying only stored in deionized water, at 37oC, during the whole experimental period. When the mechanical cycling was over, buccal dental surfaces were, then, covered with two layers of the adhesive system (Single Bond®), now modified by the addition of fluorescein, for delimitation of the possible formed defects. Teeth were longitudinally sectioned into two halves (mesial and distal ones), and submitted to evaluation through confocal microscopy, for analysis of the restorations marginal quality. Chi-square test (p<0.05) was applied for evaluation of qualitative variables (presence or absence of marginal defects and their location according to the cavity walls occlusal, cervical or both); and Kruskal-Wallis test (p<0.05) was applied for evaluation of quantitative variables (length and width of the defects). Specimens submitted to occlusal loading, independently of the location of the tip, presented a higher percentage of marginal defects (53.33%), when compared to the control group (10%; p=0.016). There was no significant statistical difference among the local of load placement for the presence or absence of marginal defects (p=0.875); for their localization according to the cavity walls (p=0.270); or even for their length (p=0.190) and width (p=0.070). It can be concluded, therefore, that occlusal loading was harmful for the margins of cervical restorations; but the different local of its incidence did not interfere with their marginal quality.
339

Efeito da base de cimento de ionômero de vidro modificado por resina e técnicas de inserção de resina composta na interface dentina/restauração adesiva / Effect of resin-modified-glass-ionomer linning and composite placement on adhesive interface

Larissa Marinho Azevedo 06 May 2011 (has links)
Este estudo teve como objetivo avaliar o efeito da base de cimento de ionômero de vidro modificado por resina (CIVMR) e das técnicas de inserção incremental de resina composta na interface de parede circundante de restauração adesiva à dentina. Foram confeccionadas cavidades com 4,5mm X 3mm X 5mm em 52 molares humanos extraídos divididos em 4 grupos: Grupo 1 (controle): Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) com inserção em 2 incrementos horizontais (Fator C = 5); Grupo 2: Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) em 4 incrementos oblíquos (Fator C=2); Grupo 3: Base de CIVMR (Vitrebond) + Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) em 2 incrementos horizontais (Fator C = 5) e Grupo 4: Base de CIVMR (Vitrebond) + Sistema Adesivo (Adper Single Bond) + Resina Composta (Filtek Z250) em 4 incrementos oblíquos (Fator C = 2). Após a restauração, os dentes permaneceram em água deionizada em estufa a 37ºC por 24 horas. Depois foram seccionados em uma máquina de cortes com disco de diamante em espessura de 0,8mm no sentido vestíbulolingual. Uma fatia de cada dente foi separada aleatoriamente para análise em Microscópio Confocal para verificação e mensuração de fendas internas na interface dentina/resina composta. As demais fatias foram seccionadas para a confecção de palitos (0,8mm X 0,8mm) que foram submetidos a testes de microtração em uma máquina de ensaios universal EMIC. Os resultados de resistência de união foram submetidos à análise de variância a dois critério ANOVA a 5% e ao teste de Fisher para as variáveis de presença de fendas internas. Não houve diferença estatisticamente significante entre os quatro grupos (p>0,05) com relação à resistência adesiva. Quanto à presença de fendas internas, foi evidenciada sua presença nos grupos 1, 3 e 4, sem diferença estatisticamente significante entre os grupos testados (p>0,05). Conclui-se, portanto, que o uso da base de cimento de ionômero de vidro modificado por resina e das técnicas de inserção incremental de resina composta não influenciam a resistência adesiva e presença de fendas da resina composta à dentina. / The aim of this study was to evaluate the effect of resin-modified-glassionomer linning and incremental technique on the bond strength of the composite restoration interface. Methods: Cavities were made (4.5mm X 3mm X 5mm) in 52 extracted human molars, divided into 4 groups: Group 1 (control) no linning + two horizontal increments (C Factor = 5); Group 2: no linning + four oblique increments (C Factor = 2); Group 3: RMGIC linning (Vitrebond) + two horizontal increments; and Group 4: RMGIC linning (Vitrebond) + four oblique increments. All teeth were restored with Adper Single Bond and Filtek Z250 and stored in deionized water at 37ºC for 24 hours before sectioned into 0.8 mm sticks (bucco-lingually). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distally) for microtensile test in a Universal Testing Machine (EMIC) at 0.5mm/min. The data were analyzed by Two-way ANOVA (5%) and Fishers test for variables of presence of gap. No statistical difference on adhesive strength among groups (G1 14.55 ± 4.228 MPa, G2 17.25 ± 7.31 MPa, G3 12.81 ± 4.97 MPa and G4 13.39 ± 4.115 MPa). No significant statistical difference was observed regarding the presence of gap at the interface dentin/resin among groups (p>0.05). It can be concluded, that resin-modified glass-ionomer cement linning and resin composite techniques showed no effect on the adhesive interface to dentin.
340

Avaliação in vitro do efeito do hidrogel de ascorbato de sódio e ácido ascórbico na resistência adesiva da resina composta ao esmalte dental bovino clareado com peróxido de hidrogênio 35% / In vitro evaluation of the effect of sodium ascorbate and ascorbic acid hydrogel in microshear bond strength of composite resin to bovine enamel bleached with 35% hydrogen peroxide

Ana Miriam Garrido De La Rosa 27 June 2011 (has links)
Acredita-se que o uso de agentes antioxidantes poderia auxiliar na restituição da resistência adesiva diminuída após o clareamento dental. O objetivo deste estudo in vitro foi avaliar o efeito do hidrogel de ascorbato de sódio a 10% e 20% e hidrogel de ácido ascórbico a 10%, aplicados por 15 minutos imediatamente após o clareamento com peróxido de hidrogênio a 35% (Lase Peroxide Sensy-DMC) (PH) na resistência adesiva imediata (24 horas) e tardia (7 dias) de uma resina composta (RC) ao esmalte bovino. Foram utilizadas 45 superfícies de esmalte de incisivos bovinos e distribuídas em 9 grupos com 5 em cada uma, sobre as quais foram confeccionados 4 corpos de prova (n= 20), de acordo com o tratamento: G1: sem clareamento (controle) + RC; G2: PH + 24h + RC; G3: PH + 7 d + RC; G4: PH + hidrogel de ascorbato de sódio 10% + 24h + RC; G5: PH + hidrogel de ascorbato de sódio a 10% + 7 d + RC; G6: PH + hidrogel de ascorbato de sódio a 20% + 24h + RC; G7: PH + hidrogel de ascorbato de sódio a 20% + 7 d + RC; G8: PH + hidrogel de ácido ascórbico a 10% + 24h + RC; G9: PH + hidrogel de ácido ascórbico a 10% + 7 d + RC. Foram confeccionados cilindros de (0.8x1mm), utilizando o sistema adesivo Single Bond 2 e a resina composta Z100 (3M ESPE) e submetidos ao teste de resistência adesiva ao microcisalhamento na máquina de ensaios universal (EMIC) com célula de carga de 50N a uma velocidade de (0,5mm/min). Posteriormente foram observados os tipos de fraturas em um estereomicroscópio com aumento de 40x. A seguir, os valores de resistência adesiva ao microcisalhamento foram avaliados estatisticamente através da Análise de Variância a um critério (ANOVA) e do teste de Tukey para comparações múltiplas, com nível de significância de 5%. Os resultados foram: G1: 24,34ab ± 5,182; G2: 15,27c ± 7,170; G3: 16,65c ± 7,614; G4: 20,30bc ± 7,071; G5: 17,77bc ± 8,135; G6: 18,03bc ± 4,016; G7: 19,60bc ± 6,396; G8: 20,03bc ± 3,941; G9: 17,63bc ± 3,390. De acordo com os resultados obtidos na presente pesquisa pode-se concluir que: a técnica de clareamento dental com peróxido de hidrogênio a 35% promoveu uma diminuição estatisticamente significante na resistência adesiva da resina composta ao esmalte bovino nos procedimentos realizados 24 horas e 7 dias após o clareamento dental. Tanto o tratamento com hidrogel de ascorbato de sódio como com o hidrogel de ácido ascórbico, independente da concentração e tempo de espera, foram capazes de melhorar a resistência adesiva da resina composta ao esmalte bovino clareado. Entretanto, ambos os tratamentos com agentes antioxidantes não foram capazes de recuperá-la. / It is referred that the use of antioxidants may improve the decreased bond strength after bleaching treatment. The aim of this in vitro study was to evaluate the effect of 10% and 20% sodium ascorbate hydrogel and 10% ascorbic acid hydrogel applied for 15 minutes immediately after 35% hydrogen peroxide bleaching (HP) (Lase Peroxide Sensy-DMC). 45 bovine incisors enamel surfaces divided into 9 groups were used. Four specimens were made on each surface (n = 20) according to the different treatments: G1: without bleaching (control group) + RC; G2 : HP + 24 h + RC; G3: HP + 7 d+ RC; G4: HP + 10% sodium ascorbate hydrogel + 24 h + RC; G5: HP + 10% sodium ascorbate hydrogel + 7 d + RC; G6: HP + 20% sodium ascorbate hydrogel + 24h + RC; G7: HP + 20% sodium ascorbate hydrogel + 7 d + RC; G8: HP + 10% ascorbic acid hydrogel + 24 h + RC; G9: HP + 10% ascorbic acid hydrogel + 7 d + RC. Cylinder restorations (0.8x1mm) were made using Single Bond 2 and Z100 (3M ESPE). Microshear bond strength test was performed using a universal testing machine (EMIC) with a 50N load at a crosshead speed of 0.5mm/min. Failure modes were assesed using a stereomicroscope (40x) showing mainly adhesive failures. Data were analyzed by ANOVA and Tukey analysis for multiple comparisons at the significance level of 5%. The results were: G1: 24.34 ± 5.182 ab G2: 15.27 ± 7.170 c; G3: 16.65 ± 7.614 c, G4: 20.30 ± 7.071 bc; G5: 17.77 ± 8.135 bc G6: ± 18.03 bc 4.016; G7: 19.60 bc ± 6.396; G8: 20.03 bc ± 3.941; G9: 17.63 ± 3.390 bc. According to the results obtained it can be concluded that: the 35% hydrogen peroxide tooth whitening technique promoted a statistically significant decrease in bond strength of resin composite to enamel performed 24 hours and 7 days after bleaching. Both treatment with sodium ascorbate hydrogel and ascorbic acid hydrogel, independent of concentration and time, were able to improve the bond strength of composite resin to bleached bovine enamel, however, both antioxidants were not able to retrieve it.

Page generated in 0.0716 seconds