• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1009
  • 30
  • 15
  • 11
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 1068
  • 562
  • 344
  • 197
  • 135
  • 108
  • 100
  • 93
  • 81
  • 80
  • 79
  • 78
  • 76
  • 75
  • 71
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
741

Análise da confiabilidade de equipamentos e métodos para medir o movimento de flexão anterior da coluna lombar.

Vieira, Edgar Ramos 21 March 2002 (has links)
Made available in DSpace on 2016-06-02T20:19:04Z (GMT). No. of bitstreams: 1 DissERV.pdf: 2566067 bytes, checksum: a74722f0f373ee69d789dc4eb2dceb64 (MD5) Previous issue date: 2002-03-21 / Current high incidence of low back pain represents high costs to patients, industries, health insurance companies and government. Moreover, it causes loss in life quality of suffers. Lumbar flexion movement is critical to the development and aggravation of low back pain. Thus, quantification of this movement is important to the prevention and treatment of these disorders. Therefore, the purposes of this research were: design two new methods to quantify lumbar flexion movement, improve electrogoniometer interfaces, and assess the reliability of three devices and methods to measure the studied movement. In order to achieve these objectives, three studies were designed. Study 1 has compared the measurements from an electrogoniometer fixed by Attachment Ducts (ADs), with those from another electrogoniometer without ADs, and the measurements of both electrogoniometers with those from a high precision goniometer. Study 2 has compared both conditions studied previously, when the electrogoniometers were fixed in parallel on lumbar muscles of 14 subjects. Study 3 presented the Perpendicular Markers Photometric Technique (PMPT) and the Distanciometer, both designed for this study. Furthermore, this study analyzed the reliability of the PMPT, fleximeters (usually known as inclinometers), and Distanciometer, when compared to the measurements of lumbar flexion movement of 25 subjects performed by an electrogoniometer. Results indicated that electrogoniometers are precise equipment, ADs did not influence measurements and provided a more specific definition of the region to be assessed by electrogoniometers, and high reliability was found for both PMPT and Distanciometer, but not for the fleximeters used in this study. / As lombalgias são de grande incidência e acarretam altos custos para os acometidos, indústrias, convênios de saúde e para o governo. Além de apresentarem repercussões negativas para a qualidade de vida dos indivíduos portadores. O movimento de flexão anterior da coluna lombar tem sido reconhecido como crítico para o desencadeamento e agravamento das lombalgias, sendo que a quantificação deste movimento é importante para a prevenção e tratamento das lombalgias. Dessa forma, os objetivos do presente trabalho foram: criar e disponibilizar duas novas formas para medir o movimento de flexão anterior da coluna lombar, aprimorar as medidas realizadas pelo eletrogoniômetro e avaliar a confiabilidade de três equipamentos e métodos para medir o movimento em questão. Para tanto, três estudos foram conduzidos. O Estudo 1 comparou as medidas de um eletrogoniômetro utilizando Canaletas de Acoplamento (CAs) com as de outro sem canaletas, e as de ambos em relação as de um goniômetro de alta precisão. O Estudo 2 comparou os dados dos dois eletrogoniômetros, citados anteriormente, acoplados paralelamente sobre a musculatura paravertebral lombar de 14 sujeitos. O Estudo 3 apresentou a Técnica Fotométrica dos Marcadores Perpendiculares (TFMP) e o Distanciômetro, que são uma nova técnica e um novo equipamento, respectivamente, e comparou as medidas do movimento de flexão anterior da coluna lombar de 25 sujeitos, realizadas pela TFMP, por flexímetros e pelo Distanciômetro, com às de um eletrogoniômetro. Os resultados mostraram que o eletrogoniômetro é um equipamento preciso, que as CAs não interferem na medida e aprimoram a definição da região mensurada pelo eletrogoniômetro. Além disso, a TFMP e o Distanciômetro mostraram-se equipamentos confiáveis para medir o movimento de flexão anterior da coluna lombar, mas não os flexímetros utilizados, que necessitam de aprimoramentos.
742

Avaliação das variáveis cardiorrespiratórias e perceptivas durante o teste de caminhada com velocidade controlada: estudo de reprodutibilidade, confiabilidade e validade na população de mulheres obesas adultas

Jürgensen, Soraia Pilon 18 July 2012 (has links)
Made available in DSpace on 2016-06-02T20:19:19Z (GMT). No. of bitstreams: 1 4543.pdf: 1379957 bytes, checksum: 76a64c72298bfebb3102cd24d039fed8 (MD5) Previous issue date: 2012-07-18 / Universidade Federal de Minas Gerais / Apesar do uso generalizado do Incremental Shuttle Walk Test (ISWT), não há estudos anteriores que avaliaram este teste na população de mulheres obesas. Portanto, o objetivo principal foi testar a reprodutibilidade e confiabilidade deste teste e sua validade em comparação com um teste em esteira (TECP). Quarenta e seis mulheres realizaram três ISWT em um corredor de 10 m, dois no mesmo dia e o terceiro com intervalo de dois a sete dias e um TECP. A idade e o índice de massa corporal médios foram de 32 anos e 35 kg/m², respectivamente. Houve diferença significativa entre o primeiro e o segundo ISWT para as variáveis cardiovasculares e distância percorrida (ISWD) (frequência cardíaca=139±16 vs. 150±18 bpm, p=0,004; pressão arterial sistólica=157±9 vs. 159±19 mmHg, p<0,001; ISWD=413±88 vs. 463±92 m,p=0,009). Não houve diferença significante para nenhuma variável mensurada entre os valores obtidos no pico do segundo com o terceiro teste, além disso, o segundo ISWT apresentou concordância com o terceiro quando analisada a diferença entre as médias das diferenças. Houve boa e excelente confiabilidade entre o segundo e terceiro ISWT quando analisada a distância (ISWD) (ICC=0,93), ventilação (ICC=0,78), consumo de oxigênio (VO2) (ICC=0,90) e produção de dióxido de carbono (ICC=0,86). O VO2 pico obtido no TECP foi significativamente correlacionado com a ISWD (r=0,54, p<0,05) e com o VO2 pico no ISWT (r=0,64, p<0,05). Em conclusão, nossos achados sugerem que o ISWT pode ser uma ferramenta válida, confiável e reprodutível para avaliação da capacidade física de mulheres adultas com obesidade.
743

Aplicação da análise de sobrevivência na estimativa da vida útil de componentes construtivos

Célio Costa Souto Maior 30 December 2009 (has links)
Este trabalho foi elaborado, na tentativa de se aplicar as técnicas e os conceitos que são empregadas na Análise de Sobrevivência, na medicina e aplicá-los na Engenharia Civil, na área de construção. Essas técnicas recebe o nome de Confiabilidade, onde permite estimar a vida útil de componentes construtivos, através de modelos probabilísticos mais usados nessa área. Esses modelos foram desenvolvidos e aplicados nos dados colhidos, com uma confiabilidade de 95%. Esse assunto, nessa área, já vem sendo estudado na comunidade científica, mas especificamente na área da construção civil pouco se conhece, encontrando-se ainda a fase embrionária, merecendo um estudo mais aprofundado. Logo nossa proposição foi a de a partir de análise feita em uma amostra para estudo, tirar algum proveito ou alguma informação que possa ajudar para trabalhos futuros. Foram coletados 60 amostras para estudo, sendo que 10 delas foram censuradas, onde o estudo terminou com um numero pré-determinado de amostras estudadas. Os resultados foram obtidos através do software R, sendo comparados os modelos Exponencial, Weibull e Log-normal, com o estimador de Kaplan-Meier, mostrando tanto graficamente como através de testes, qual melhor modelo se ajusta aos dados coletados. O modelo que melhor se ajustou foi o Log-normal / This Work was developed as an effort to utilize the techniques and concepts that are employed in Survival Analysis in medicine, in order to apply them in Civil Engineering in the construction area. These techniques is called Reliability, which allows estimating the life time of building components through probabilistic models commonly used in that area. These models were developed and applied to the collected data, with a reliability of 95%. This subject, in this area have been studied in the scientific community, but specifically in the construction area is poorly known and is still in its beginning and, deserves further study. Thus, our proposition was to take some benefit or some information that might help for future work from analysis of a sample to study. 60 samples were collected for study, and 10 of them were censored, so that the study ended with a predetermined number of samples. The results were obtained using the software R and compared the models Exponential, Weibull and Log-normal, with the Kaplan-Meier estimator showing both graphically and through tests, which model best fits the data collected. The model that best fitted was the lognormal
744

Qualidade da alvenaria estrutural em habitações de baixa renda : uma análise de confiabilidade e da conformidade / Quality of structural masonry in low-income housing projects : an analysis of reliability and conformance

Richter, Cristiano January 2007 (has links)
A alvenaria estrutural tem sido amplamente empregada na construção civil brasileira, sendo o segmento de empreendimentos habitacionais de baixa renda uma de suas principais aplicações. Neste segmento de mercado, a qualidade das edificações tem sido estudada por diversos autores. Porém, poucos destes estudos reconheceram o caráter multidimensional da qualidade e tampouco explicitaram a perspectiva da qualidade que estava sendo utilizada. Nos empreendimentos habitacionais de baixa renda, as dimensões da qualidade de confiabilidade e conformidade são fundamentais. Neste sentido, o presente trabalho teve como objetivo principal analisar a relação das não-conformidades do processo construtivo de alvenaria estrutural em empreendimentos habitacionais de baixa renda com a confiabilidade do produto. Esta análise foi realizada em oito empreendimentos concluídos e em oito empreendimentos em construção no Estado do Rio Grande do Sul, relativos a dois programas promovidos pela CAIXA: o Programa de Arrendamento Residencial e do Programa Imóvel na Planta. Para mensurar a confiabilidade do produto foi proposto um método de análise sistemática por observação direta de manifestações patológicas. A aplicação deste método resultou num coeficiente de defeitos por unidades (CDU), o qual apresentou diferenças significativas entre os empreendimentos estudados. A partir da análise das não-conformidades foi possível identificar as principais oportunidades e barreiras à melhoria da alvenaria estrutural nestes empreendimentos. Estes fatores foram analisados tanto no processo de construção destes empreendimentos como no processo de avaliação da qualidade adotado pela CAIXA. / Structural masonry has been widely used in the Brazilian construction industry. One of the main applications in Brazil has been in the low-income housing project segment. Several authors have studied the quality of construction in this segment. However, most studies do not take into account the multidimensional character of quality, and only a few define the dimension of quality that has been considered. The dimensions of reliability and conformance are fundamental in low-income housing projects. The main objective of this dissertation is to analyze the relationship between nonconformances of structural masonry in low-income housing and product reliability. This analysis involved eight housing projects already delivered to the users as well as eight housing projects under construction, all of them located in the state of Rio Grande do Sul, Brazil. Those housing projects are part of two programs promoted by the Brazilian Public Savings Bank: The Residential Leasing Program and the Building Plan Program (Programa Imóvel na Planta). In order to measure the reliability of the product, a method of systematic analysis by direct observation of structural masonry failures was used. The application of this method resulted in a measure of defective elements (CDU), which indicated significant differences on the quality between the housing projects that were studied. It was possible to identify opportunities for improvement in structural masonry based on the analysis of non conformances. These factors were analyzed during the construction process as well as during the quality control process conducted by the Public Savings Bank.
745

AFIDS : arquitetura para injeção de falhas em sistemas distribuídos / AFIDS - architecture for fault injection in distributed systems

Sotoma, Irineu January 1997 (has links)
Sistemas distribuídos já são de amplo uso atualmente e seu crescimento tende a se acentuar devido a popularização da Internet. Cada vez mais computadores se interligam e trocam informações entre si. Nestes sistemas, requerimentos como confiabilidade, disponibilidade e desempenho são de fundamental importância para a satisfação do usuário. Estes requerimentos podem ser atendidos aproveitando-se da redundância já existente com as maquinas interligadas. Mas para atingir os requisitos de confiabilidade e disponibilidade, protocolos tolerantes a falhas devem ser construídos. Tolerância a falhas visa continuar a fornecer o serviço de algum protocolo, aplicação ou sistema a despeito da ocorrência de falhas durante a sua execução. Tolerância a falhas pode ser implementada por hardware ou por software através de mascaramento ou recuperação de falhas. Recentemente, a injeção de falhas implementada por software tem sido um dos principais métodos utilizados para validar protocolos tolerantes a falhas em sistemas distribuídos, e muitas ferramentas tem sido construídas. Contudo, não ha nenhuma biblioteca de classes orientada a objetos para auxiliar novos pesquisadores na construção da sua própria ferramenta de injeção de falhas. Este trabalho apresenta uma proposta de uma arquitetura orientada a objetos escrita em C++ para sistemas operacionais UNIX usando sockets, de modo a alcançar aquele objetivo. Esta arquitetura é chamada de AFIDS (Architecture for Fault Injection in Distributed Systems). AFIDS pretende fornecer uma estrutura básica que aborda as questões principais no processo de injeção de falhas implementada por software: a) a Geraldo de parâmetros de falhas para o experimento, b) o controle da localização, tipo e tempo da injeção de falhas, c) a coleta de dados do experimento, d) a injeção efetiva da falha e a análise dos dados coletados de modo a obter medidas de dependabilidade sobre o protocolo tolerante a falhas. Ou seja, AFIDS pretende ser um framework para a construed° de ferramentas de injeção de falhas. Segundo [BOO 961: "Através do uso de frameworks maduros, o esforço de desenvolvimento torna-se mais fácil, porque os principais elementos funcionais podem ser reutilizados". AFIDS leva em consideração várias questões de projeto que foram obtidas através da analise de oito ferramentas de injeção de falhas por software para sistemas distribuídos: FIAT [SEG 88], EFA [ECH 92. ECH 94], SFI [ROS 93], DOCTOR [HAN 93], PFI [DAW 94], CSFI [CAR 95a], SockPFI [DAW 95] e ORCHESTRA [DAW 96]. Para auxiliar a construção de AFIDS, é apresentada uma ferramenta de injeção de falhas que utiliza um objeto injetor de falhas por processo do protocolo sob teste. AFIDS e esta ferramenta são implementadas em C++ usando sockets em Linux. Para que AFIDS se tome estável e consistente e necessário que outras ferramentas sejam construídas baseadas nela. Isto é enfatizado porque, segundo [BOO 96]: "Um framework são começa a alcançar maturidade apos a sua aplicação em pelo menos três ou mais aplicações distintas". / Currently, distributed systems are already in wide use. Because of the Internet popularization their growth tend to arise. More and more computers interconnect and share information. In these systems, requirements such as reliability, availability and performance are fundamental in order to satisfy the users. These requirements can be reached taking advantage of the redundancy already associated with the computers interconnected. However, to reach the reliability and availability requirements, fault tolerant protocols must be built. Fault tolerance aims to provide continuous service of some protocol, application or system in despite of fault occurrence during its execution. Fault tolerance can be implemented in hardware or software using fault masking or recovery. Recently, the software-implemented fault injection has been one of the main methods used to validate fault tolerant protocols in distributed systems, and many tools has been built. However, there is no object-oriented class library to aid new researchers on the buildin g of own fault injection tool. This work presents a proposal of an objectoriented architecture written in C++ for UNIX operating systems using sockets, in order to reach that purpose. This architecture is called AFIDS (Architecture for Fault Injection in Distributed Systems). AFIDS intends to provide a basic structure that addresses the main issues of the process of software-implemented fault injection: a) the generation of fault parameters for the experiment, b) the control of the location, type and time of the fault injection, c) the data collection of the experiment, d) the effective injection of the faults, and e) the analysis of collected data in order to obtain dependability measures about the fault tolerant protocol sob test. According to [BOO 96]: "By using mature frameworks, the effort of the development team is made even easier, because now major functional elements can be reused.". AFIDS regards various design issues that were obtained from the analysis of eight tools of software-implemented fault injection for distributed systems: FIAT [SEG 88], EFA [ECH 92, ECH 94], SFI EROS 93], DOCTOR [HAN 93], PFI [DAW 94], CSFI [CAR 95a], SockPFI [DAW 95] e ORCHESTRA [DAW 96]. In order to aid the AFIDS building, a fault injection tool that uses one injector object in each process of protocol under test is shown. AFIDS and this tool are implemented in C++ using sockets on Linux operating system. AFIDS will become stable and consistent after the building of others tools based on it. This is emphasized because, according to [BOO 96]: "A framework does not even begin to reach maturity until it has been applied in at least three or more distinct applications".
746

Estudo do torque de acionamento e vida útil de um projeto de válvulas industriais

Costa, Mauro Luís de Oliveira January 2009 (has links)
O objetivo principal deste trabalho é a análise e possível otimização de um projeto de válvulas de esfera. É apresentado um estudo para determinação do torque de acionamento de válvulas de esfera industriais, bem como um estudo de vida útil das válvulas. Os estudos foram realizados utilizando projeto de experimentos e permitiram a construção de modelos de previsão de torque e de previsão de vida útil. A previsão de torque é fundamental para possibilitar a otimização do projeto das válvulas, na fase de desenvolvimento do produto. O uso dos modelos permitiu a determinação do ajuste ótimo, levando em conta pressão, temperatura, esmagamento das sedes, torque de aperto na porca da haste e torque de acionamento desejado. Já os estudos de vida útil são importantes para informar à empresa o número de ciclos até o vazamento. Os resultados do estudo, realizado através de ensaios acelerados, permitiram a construção de modelos de confiabilidade associada ao número de ciclos de operação, permitindo assim a avaliação e possível melhoria do projeto das válvulas. / The main objective of this dissertation is the analysis and optimization of a ball valve project. A study for determining the operational torque of industrial ball valves as well as a life study of valves are presented. The studies were performed using design of experiments and allowed the construction of torque and life prevision models. The prevision of torque is fundamental to enable project optimization on the phase of product development. Results allowed the definition of an optimal setting regarding pressure, temperature, seats tightening, stem nut tightening torque and the desired operational torque. Further, the life studies are helpful to inform the company the number of cycles until leakage. Results, obtained through accelerated tests, allowed the construction of reliability models associated to the number of operational cycles, conducting to valve design evaluation and optimization.
747

Reintegração de servidores em sistemas distribuídos / Reintegration of failed server in distributed systems

Pasin, Marcia January 1998 (has links)
Sistemas distribuídos representam uma plataforma ideal para implementação de sistemas computacionais com alta confiabilidade e disponibilidade devido a redundância fornecida por um grande número de estações interligadas. Falhas de um servidor podem ser contornadas pela reconfiguração do sistema. Entretanto falhas em seqüência que afetem múltiplas estações comprometem não apenas o desempenho do sistema, mas também a continuidade do serviço e sua confiabilidade. Assim, servidores falhos, que tenham sido isolados do sistema, devem ser reintegrados tão logo quanto possível para não comprometer a disponibilidade do sistema computacional. Este trabalho trata da atualização do estado de servidores e da troca de informação que o servidor recuperado realiza para integrar-se aos demais membros do sistema através de um procedimento chamado reintegração do servidor. E assumido um ambiente distribuído que garante alta confiabilidade em aplicações convencionais através da técnica de replicação de arquivos. O servidor a ser reintegrado faz parte de um grupo de replicação e volta a participar ativamente do grupo tão logo seja reintegrado. Para tanto, considera-se a estratégia de replicação por copia primaria e um sistema distribuído experimental, compatível com o NFS, desenvolvido na UFRGS para aplicar a reintegração de servidor. Os métodos de atualização de arquivos para a reintegração do servidor foram implementadas no ambiente UNIX. / Distributed systems are an ideal platform to develop high reliable computer applications due to the redundancy supplied by a great number of interconnected workstations. Failed stations can be masked reconfiguring the system. However, sequential faults, that affect multiple stations, not just decrease the performance of the system, but also affect the continuity of the service and its reliability. Thus, failed stations working as servers, that have been isolated from the system, should be reintegrated as soon as possible to not impair the system availability. This work is exactly about methods to update the state of failed servers. It deals also with the change of information that the recovered server accomplishes to be integrated to the other members of the service group through a process called reintegration of server. It is assumed a distributed environment that guarantees high reliability in conventional applications through replication of files. The server to be reintegrated is part of a replication group and it participates actively of the service group again as soon as it is reintegrated. Our approach is based on a primary copy. The file actualization methods to the reintegration of server were implemented in an UNIX environment. To illustrate our approach we will describe how the integration of repaired server can be made a fault-tolerant system. The experimental distributed system, compatible with NFS, was designed at the UFRGS.
748

Confiança em rede : a experiência da rede de estofadores do pólo moveleiro de Bento Gonçalves

Balestro, Moisés Vilamil January 2002 (has links)
Esta dissertação é um estudo exploratório a respeito do papel da confiança nas redes simétricas de empresas enquanto principal mecanismo de coordenação nas relações entre as empresas. O estudo analisa a experiência de uma rede de pequenas empresas estofadoras do Sistema Local de Produção Moveleiro de Bento Gonçalves, Rio Grande do Sul. A rede foi formada a partir de um programa governamental. Na parte teórica, é feita uma revisão sobre a cooperação interorganizacional e arranjos em rede. A revisão também incluiu os mecanismos de coordenação presentes nas redes, o conceito de confiança (sua relação com o imbricamento social) e o seu papel nas relações interorganizacionais. No final da parte teórica, é apresentado um modelo para analisar a confiança nas relações interorganizacionais dentro da rede. Na segunda parte, depois de dar algumas informações sobre a indústria moveleira do Rio Grande do Sul, é feita uma análise da rede tendo em vista as características e mecanismos de coordenação apresentados na revisão de literatura. Na seqüência, são feitas considerações sobre o caráter temporário ou estratégico desse tipo de arranjo interorganizacional. Também é feita a aplicação do modelo e analisado como a confiança é vista pelas empresas da rede. Conforme sugerido pela literatura, os resultados da análise indicam um papel muito importante da confiança e do imbricamento social no início e manutenção das relações interorganizacionais dentro da rede. Os resultados contribuem com o tema emergente do papel da confiança em redes de empresas. As contribuições são importantes tanto para pequenas empresas que queiram se organizar em rede quanto para instituições e formuladores de política pública.
749

Manutenção centrada em confiabilidade aplicada à gestão de linhas de transmissão localizadas em áreas de ocupação irregular de faixa de passagem.

SOUZA, Antonio Carlos Vieira de. 02 February 2018 (has links)
Submitted by Dilene Paulo (dilene.fatima@ufcg.edu.br) on 2018-02-02T12:32:22Z No. of bitstreams: 1 ANTONIO CARLOS VIEIRA DE SOUZA – DISSERTAÇÃO PPGEE 2014.pdf: 9911123 bytes, checksum: 979643fcec25e78fa35aa4397666c409 (MD5) / Made available in DSpace on 2018-02-02T12:32:22Z (GMT). No. of bitstreams: 1 ANTONIO CARLOS VIEIRA DE SOUZA – DISSERTAÇÃO PPGEE 2014.pdf: 9911123 bytes, checksum: 979643fcec25e78fa35aa4397666c409 (MD5) Previous issue date: 2014 / Este trabalho visa a aplicação da metodologia Manutenção Centrada na Confiabilidade – MCC, através de um projeto piloto em uma unidade de manutenção de linhas de transmissão da Companhia Hidro Elétrica do São Francisco – Chesf. Devido às dificuldades da eliminação dos problemas da ocupação de faixa de linhas de transmissão, o objetivo desta aplicação é reduzir os riscos de acidentes com pessoas que ocupam estas áreas através da mudança nos processo da manutenção de linhas transmissão. Inicialmente é feita a apresentação dos componentes mais críticos das linhas de transmissão, sobre a ótica da segurança, e a identificação dos seus principais modos de falha, assim como, sobre as metodologias de manutenção de linhas de transmissão usadas atualmente. O processo de implantação é feito de forma sistemática e seguindo a estratégia clássica e sequenciada que é a seleção do sistema e coleta de informações, a análise de modos de falhas e efeitos, a seleção das funções significantes, e das atividades aplicáveis, a avaliação das atividades, em seguida é realizada a seleção das atividades para finalmente ser definida a periodicidade das atividades. Verifica-se a eficácia da metodologia, pois após as realização das análises necessárias, conclui-se que é necessário uma metodologia diferenciada para a manutenção de linhas de transmissão, cujas faixas de passagem foram ocupadas irregularmente, certamente a aplicação da metodologia contribuirá para o objetivo maior que é a redução dos riscos existentes nestas linhas de transmissão. / This work aims at applying the methodology Reliability Centered Maintenance - RCM, through a pilot project in a maintenance unit transmission lines of the Companhia Hidro Elétrica do São Francisco – Chesf. Due to the difficulties of eliminating the problems of occupation range of transmission lines, the objective of this methodology is to reduce the risk of injury to persons occupying these areas through the change process in the maintenance of transmission lines. Initially the presentation of the most critical components of the transmission lines on the viewpoint of security, and identification of their major failure modes is taken as well as the methodologies for maintenance of transmission lines used today. The deployment process is done systematically and following the classic strategy and sequenced that is the selection of the system and information collection, analysis of failure modes and effects, the selection of the significant functions and activities applicable to assessment effectiveness of activities, then the selection of effective activities is made the frequency of activities to finally be set. Verifies the effectiveness of the methodology, since after the requisite tests, it is concluded that a different methodology for the maintenance of transmission lines present in areas of irregular occupation of track is required in addition to application of Reliability Centered Maintenance brings us to our goal is the reduction of existing risks in these transmission lines.
750

Instalação de medidores inteligentes: uma análise de confiabilidade na rede de distribuição de energia / Installation of smart meters: an analysis of reliability in distribution system

Hammarstron, Júlia Rambo 26 August 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Power outages can cause great harm to consumers, especially for commerce and industry. Therefore, it is important that the utilities attend the emergency occurences as fast as possible. In this context, it is done an avaliation of the reduction of the time of the emergency occurences after the exchange of conventional meters for smart meters. These meters provide instant information of the conditions of the distribution network, including the outages. The utility is immediately informed about the outage of energy, getting through this the exact location of the defect. Therefore, the exchange of the meters provides a reduction of the fault location time, with consequent reduction of the time of attendance of occurrences, whose values are monitored by the brazilian Electric Agency. As a consequence of this reduction, there is a reduction of individual continuity índex Customer Average Interruption Duration Index (CAIDI), equivalent índex "System Average Interruption Duration Index" (SAIDI) and Expected Energy Not Supplied (EENS). This paper analyze the reduction of SAIDI and EENS in a distributor of Brazil, using scenarios of exchange of meters defined by Monte Carlo Method (MCM). The results demonstrate a reduction in SAIDI and EENS, but possibly the location where the search was conducted contributed to this reduction was not as significant as expected. / Interrupções de energia podem ocasionar grandes prejuízos aos consumidores, especialmente para o comércio e indústria. Por isso, torna-se importante que as concessionárias realizem o atendimento as ocorrências emergenciais de forma mais rápida possível. Nesse contexto, é realizada a avaliação da redução do tempo de atendimento as ocorrências emergenciais através da troca de medidores convencionais por medidores inteligentes. Esses medidores proporcionam a informação instantânea das condições da rede de distribuição, inclusive no que se refere a interrupções de energia. Através dos novos medidores, a concessionária é informada imediatamente sobre a falta de energia, obtendo através disso a localização exata do defeito ocorrido na rede de baixa tensão (BT). Portanto, a troca de medidores proporciona a redução do tempo de localização do defeito, com consequente redução do tempo de atendimento às ocorrências, cujos valores são fiscalizados pela Agência Nacional de Energia Elétrica (ANEEL). Como consequência dessa redução, tem-se a redução do indicador de continuidade individual - Duração Individual por Unidade Consumidora (DIC) - e coletivo - Duração Equivalente por Unidade Consumidora (DEC) ambos limitados pela ANEEL. Além disso, ocorre redução da Energia Não Distribuída (END). Este trabalho realiza a análise de redução de DEC e END em uma Concessionária de Distribuição de Energia Elétrica do interior do Rio Grade do Sul, através de cenários de trocas de medidores definidos pelo Método de Monte Carlo (MMC). Os resultados demonstram que há redução de DEC e END, mas que possivelmente o local onde foi realizada a pesquisa colaborou para que essa redução não fosse tão significativa.

Page generated in 0.0532 seconds