• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1009
  • 30
  • 15
  • 11
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 1068
  • 562
  • 344
  • 197
  • 135
  • 108
  • 100
  • 93
  • 81
  • 80
  • 79
  • 78
  • 76
  • 75
  • 71
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
781

MODELAGEM DE CARGA DE UMA INDÚSTRIA DE GRANDE PORTE PARA ANÁLISE DE PROBLEMAS DE TENSÃO NO REGIME DINÂMICO / MODELING OF A LOAD OF BIG INDUSTRY FOR ANALYSIS OF PROBLEMS TENSION IN THE SCHEME OF DYNAMIC

Silva, Fábio Mendes da 27 October 2006 (has links)
Made available in DSpace on 2016-08-17T14:53:13Z (GMT). No. of bitstreams: 1 Fabio Mendes.pdf: 1170710 bytes, checksum: 82680998b91c71d757e674e600fb9799 (MD5) Previous issue date: 2006-10-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The present work proposes an extended model representing part of a huge aluminum industry load for voltage stability investigations in time domain. The efforts were concentrated in the expansion of the industrial power distribution system model including explicit representation of the main transformers, capacitors, feeders and induction motors. The extended model is validated through a comparison between computer simulation results and the industry/power system utility recordings. A real sequence of events which took place in the Brazilian North Power System in the year of 2002 causing a complete industry breakdown (loss of bulk supply) was considered here for this purpose. / Este trabalho propõe um modelo estendido representando parte da carga de uma indústria de grande porte de alumínio para investigações do fenômeno da estabilidade de tensão no domínio do tempo. Os esforços se concentraram na expansão do modelo do sistema de distribuição industrial incluindo uma representação explícita dos principais transformadores, capacitores, alimentadores e motores de indução. O modelo expandindo é validado através de uma comparação entre os resultados das simulações computacionais e o de registradores alocados na indústria e no sistema elétrico. Uma seqüência real de eventos ocorrida no Sistema Elétrico do Norte do Brasil no ano de 2002 causando uma perda completa da indústria foi considerada para tal fim.
782

Reprodutibilidade da hipotensão pós-exercício e de seus mecanismos hemodinâmicos e autonômicos / Reproducibility of post-exercise hypotension and its hemodynamic and autonomic mechanisms

Rafael Yokoyama Fécchio 16 October 2017 (has links)
A hipotensão pós-exercício (HPE) se caracteriza pela redução da pressão arterial (PA) após uma sessão de exercício. Diversos estudos têm investigado a HPE e seus mecanismos utilizando as seguintes formas de cálculo: I = PA pós-exercício - PA pré-exercício; II = PA pós-exercício - PA pós-controle; e III = [(PA pós-exercício - PA pré-exercício) - (PA pós-controle - PA pré-controle)]. Embora esses estudos tenham demonstrado a ocorrência da HPE em diferentes populações e sua relevância clínica, pouco se sabe sobre sua reprodutibilidade. Dessa forma, este estudo objetivou verificar a reprodutibilidade (erro sistemático, confiabilidade e concordância) da HPE e de seus mecanismos hemodinâmicos e autonômicos avaliados pelas 3 formas de cálculo expostas. Para tanto, 30 indivíduos realizaram 4 sessões experimentais divididas em 2 blocos (teste e reteste). Cada bloco foi composto por uma sessão de exercício (cicloergômetro, 45min, 50% do VO2pico) e uma controle (repouso sentado), realizadas em ordem aleatória. Antes e após as intervenções, foram medidos: a PA (auscultatória e fotopletismográfica), o débito cardíaco (reinalação de CO2), a frequência cardíaca (FC - eletrocardiograma) e a modulação autonômica cardiovascular (análise espectral das variabilidades da FC e da PA, além da sensibilidade barorreflexa). A presença de erro sistemático foi avaliada pelo test-t pareado, a confiabilidade pelo coeficiente de correlação intraclasse (CCI) e a concordância pelo erro típico (ET). A HPE e seus mecanismos hemodinâmicos e autonômicos avaliados pelas 3 formas de cálculo não apresentaram erro sistemático. A HPE sistólica apresentou confiabilidade alta e a diastólica confiabilidade baixa a moderada, com melhor confiabilidade na forma de cálculo II. Em geral, os mecanismos hemodinâmicos e autonômicos apresentaram confiabilidade moderada a baixa, com maior confiabilidade com a forma de cálculo I. Para finalizar, os parâmetros de concordância variaram entre as 3 formas de cálculo, o que implica que o ET específico de cada variável para cada forma de cálculo deve ser considerado para a estimativa do tamanho amostral necessário em estudos e para o cálculo da mínima diferença detectável na prática clínica quando o objetivo for comparar as respostas pós-exercício obtidas em diferentes condições / Post-exercise hypotension is characterized by a reduction in blood pressure (BP) after a single session of exercise. Several studies have investigated PEH and its mechanisms and they have employed the following methods of calculation: I = post-exercise BP - pre-exercise BP; II = post-exercise BP - post-control BP; and III = [(post-exercise BP - pre-exercise BP) - (post-control BP - pre-control BP)]. Although these studies have demonstrated the occurrence of PEH in different populations and its clinical relevance, little is known about the reproducibility of PEH. Thus, the current study was designed to determine the reproducibility (systematic error, reliability and agreement) of PEH and its hemodynamic and autonomic mechanisms evaluated by the three methods of calculation exposed. For this purpose, 30 subjects performed 4 experimental sessions divided into two blocks (test and retest). Each block was composed by one exercise (cycle ergometer, 45 min, 50% of VO2peak) and one control (seated rest) session executed in a random order. Before and after the interventions, the following parameters were measured: BP (auscultatory and photoplethysmographic), cardiac output (CO2 rebreathing), heart rate (HR - electrocardiogram) and cardiovascular autonomic modulation (spectral analysis of HR and BP variabilities, as well as spontaneous baroreflex sensitivity). The presence of systematic bias was evaluated by paired t-test, reliability by intraclass correlation coefficient (ICC) and agreement by typical error (TE). PEH and its hemodynamic and autonomic mechanisms evaluated by the three methods of calculation did not present systematic bias. Systolic PEH presented high reliability and diastolic PEH showed low to moderate reliability, with better results for the method II. In general, the hemodynamic and autonomic mechanisms presented low to moderate reliabilities, with better results for the method I. Lastly, agreement parameters varied among the three methods of calculation, which implies that the specific value of TE for each variable and each method of calculation should be used for estimating the sample size required in studies and establishing the minimal detectable change in clinical settings when the goal is to compare post-exercise responses obtained in different conditions
783

Situacoes incomodas no trabalho: confiabilidade de uma escala de medida utilizando o coeficiente alfa ordinal

Corrêa, Clorivaldo Rocha 11 May 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-21T12:23:03Z No. of bitstreams: 1 clorivaldorochacorrea.pdf: 464732 bytes, checksum: 76ad16e35afb55225dff5ec667f75f16 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-30T14:57:22Z (GMT) No. of bitstreams: 1 clorivaldorochacorrea.pdf: 464732 bytes, checksum: 76ad16e35afb55225dff5ec667f75f16 (MD5) / Made available in DSpace on 2016-06-30T14:57:22Z (GMT). No. of bitstreams: 1 clorivaldorochacorrea.pdf: 464732 bytes, checksum: 76ad16e35afb55225dff5ec667f75f16 (MD5) Previous issue date: 2012-05-11 / O estudo e a preocupação com o ambiente de trabalho e a sua influência no processo saúde-doença dos trabalhadores não é recente. Ao longo do desenvolvimento da sociedade, os fatores de riscos relacionados à Saúde do Trabalhador, foram sofrendo modificações com novos determinantes sendo incorporados. Neste contexto é que desenvolvemos este trabalho que consiste em estudo de confiabilidade de uma escala sobre situações incômodas no trabalho, utilizando uma nova metodologia denominada de Coeficiente Alfa Ordinal. A escala citada foi extraída do instrumento “Inquérito Saúde e Trabalho” – INSAT, elaborado originalmente em Portugal e adaptado linguisticamente para o Brasil, passando a ser denominado INSATS-BR. Esta escala também está inserida no instrumento a ser empregado em um estudo prospectivo de coorte intitulado “I Inquérito Sobre Condições de Trabalho e de Vida dos Técnicos Administrativos em Educação da Universidade Federal de Juiz de Fora”. A referida é composta de dezoito questões, e foi testada e retestada em cento e três trabalhadores terceirizados, em uma universidade pública, situada no Estado de Minas Gerais. A confiabilidade foi estimada pela consistência interna através dos coeficientes Alfa Ordinal e Ômega de McDonald, com resultados de 0,94 e 0,96 respectivamente. E a reprodutibilidade através do método do Teste Reteste, através da analise do Coeficiente Kappa que evidenciou correlação entre os itens do teste e do reteste variando entre 0,36 a 0,63, com Kappa médio de 0,49. Evidenciando que a Escala de Incômodos do INSATS-BR possui confiabilidade podendo ser utilizada em outros estudos. / The study and care about the working environment and its influence on health-disease process of workers is not new. Throughout the development of society, the risk factors related to worker's health was suffering with changes being incorporated into new determinants. In this context we developed this work is to study the reliability of a range of uncomfortable situations at work, using a new methodology called Ordinal Coefficient Alpha. The scale of the instrument was extracted mentioned "Work and Health Survey" - INSAT, originally developed in Portugal and linguistically adapted to Brazil, becoming known as BR-INSATS. This scale is also inserted into the instrument to be used in a prospective cohort study entitled "I Survey on Conditions of Work and Life of Technical Administrators in Education, Federal University of Juiz de Fora." That consists of eighteen questions and was tested and retested in one hundred and three contract workers, in a public university located in the State of Minas Gerais. Reliability was estimated by using the coefficients of internal consistency Alpha and Omega Ordinal McDonald, with results of 0.94 and 0.96 respectively. And by the reproducibility of the method of Test Retest by Kappa coefficient analysis of which showed correlation between the items of the test and retest ranged from 0.36 to 0.63, with mean Kappa of 0.49. Evidence that the INSATS -BR Uncomfortable Scale is reliable and can be used in other studies.
784

Análise da capacidade de carga de fundação por sapatas executadas na cidade de São Caetano do Sul/SP / Bearing capacity analysis of shallow foundation in São Caetano do Sul city

Noguchi, Leandro Tomio 20 August 2018 (has links)
Orientador: Paulo José Rocha de Albuquerque / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-20T07:37:54Z (GMT). No. of bitstreams: 1 Noguchi_LeandroTomio_M.pdf: 6042585 bytes, checksum: 3b22b2450a9ddc40e2911dbb661a0359 (MD5) Previous issue date: 2012 / Resumo: Este trabalho teve o objetivo estudar às formulações e teorias de capacidade de carga e previsão de recalques para o caso de uma solução em fundação superficial adotado em uma obra de um edifício comercial de 10 pavimentos e 3 subsolos localizado na cidade de São Caetano do Sul/SP, por meio de análise de quatro provas de carga sobre placa. Para tal, o solo local foi submetido a ensaios de laboratório para caracterização e determinação de parâmetros geotécnicos que alimentaram os métodos propostos e apresentados na literatura. Um modelo do ensaio de carga foi simulado em programa de elementos finitos, com os parâmetros dos ensaios de laboratório e assim determinando a curva carga vs recalque. Foram realizadas análises probabilísticas que forneceram o índice de confiabilidade e a probabilidade de ruína, possibilitando a redução do fator de segurança da fundação e o aumento da tensão admissível / Abstract: This work aims to study the methods and theories of bearing capacity and settlement prediction for the solution of a shallow foundation adopted in a commercial building of 10 floors and 3 basements in the city of São Caetano do Sul/SP through analysis of 4 plate loading tests. An undisturbed soil sample was collected that was submitted to laboratory tests for characterization and determination of geotechnical parameters that will support the theoretical methods proposed in the literature. With this it is expected to check the existing calculation methods for bearing capacity and settlement prediction. A model of the load plate test was simulated using a finite element program, with the parameters of laboratory tests, thus determining the load-settlement curve. By the allowable stress obtained, probabilistic analysis were performed, what made possible the calculation of reliability and failure probability indexes, allowing the reduction of the safety factor of the foundation and increase in the allowable stress / Mestrado / Geotecnia / Mestre em Engenharia Civil
785

Confiabilidade dos dados declarados ao Sistema de Informações sobre Orçamentos Públicos em Saúde pelos municípios de Pernambuco

GONÇALVES, Rogério Fabiano 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:13:40Z (GMT). No. of bitstreams: 2 arquivo4153_1.pdf: 1129040 bytes, checksum: cb9f73f1fc8f1bcf58eff36e213b3118 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / No Brasil, após quase vinte anos de vigência da carta constitucional de 1988, a discussão acerca do financiamento da saúde pública permanece na ordem do dia e expõe a fragilidade do Estado na garantia dos preceitos constitucionais da atenção à saúde. O cumprimento da Emenda Constitucional n. 29/2000 (EC29) tem sido objeto de reflexão e as evidências do atendimento à Lei assumem a centralidade do debate em torno do desempenho das unidades da Federação no cumprimento das metas. No campo das políticas de informação em saúde, o aprimoramento do Sistema de Informações sobre Orçamentos Públicos em Saúde (Siops) tem conferido maior acessibilidade e visibilidade aos dados financeiros da União, estados e municípios, sendo o instrumento de acompanhamento da EC29. Contudo, diante do caráter declaratório dos dados que alimentam o Siops, aliado ao grande número de municípios do país, a verificação de consistência dos dados municipais não é realizada pela equipe técnica do Siops. Nesse sentido, o estudo em pauta investiga um atributo essencial a qualquer informação a confiabilidade, avaliando a efetivação do direito à saúde no cumprimento à EC29 em Pernambuco, no período de 2000 a 2005, tomando como parâmetro os demonstrativos contábeis auditados pelo Tribunal de Contas do Estado (TCE). O plano de análise, estruturado em três etapas, constou da utilização do Coeficiente de Correlação Intraclasses (ICC) como prova estatística na medição da concordância dos dados, além da realização de outros procedimentos. Os resultados demonstraram a dissonância existente entre as duas fontes de informações, sugerindo um nível de concordância discreto a moderado entre os dados do Siops e do TCE. O cumprimento da EC29 no Estado apresentou uma redução nos últimos anos, destacando-se o fato dos municípios menores terem melhor desempenho na obtenção das metas da EC29 em relação aos de grande porte. As diferenças encontradas pressupõem a falta de consenso pelos municípios acerca da composição das receitas e despesas vinculadas à saúde e a efetivação do direito à saúde não segue um padrão uniforme, não ocorrendo a contento, mesmo diante do empenho da maioria dos municípios no atendimento à Lei
786

[en] METROLOGICAL ASSESSMENT ON PLASMA SPECTROMETRY TECHNIQUE BY ELECTRIC SPARK IN ORDER TO CHARACTERIZE THE STEEL SAMPLES OF CST`S CONTROL PROCESS / [pt] AVALIAÇÃO METROLÓGICA DA TÉCNICA DE ESPECTROMETRIA DE PLASMA POR CENTELHAMENTO ELÉTRICO PARA CARACTERIZAÇÃO DE AMOSTRAS DE AÇO DO CONTROLE DO PROCESSO DA CST

MARCIA SPELTA DE OLIVEIRA 08 March 2006 (has links)
[pt] Esta dissertação de mestrado tem o seu foco no procedimento metodológico para análise de aço realizada no laboratório químico da aciaria da Companhia Siderúrgica de Tubarão para a certificação do produto e do processo. Neste procedimento, utiliza-se um equipamento de espectrometria baseado na emissão da radiação de átomos excitados presentes em um plasma gerado por uma centelha elétrica. O equipamento está configurado para analisar, simultaneamente teores de 18 elementos presentes em uma amostra de aço. O trabalho focou na estrutura de confiabilidade metrológica implantado no laboratório da CST, principalmente quanto ao procedimento de validação de métodos onde foram avaliadas as características de performance: Seletividade, Linearidade, Limite de detecção, sensibilidade, exatidão, precisão (repetitividade, reprodutibilidade) e robustez, conforme descrito no documento normativo do INMETRO (DOQCGCRE- 0008), mostrando assim que o método utilizado é adequado ao uso. Foi também dada uma especial atenção aos parâmetros de controle do equipamento analítico, a luz dos princípios básicos da técnica de espectroscopia de plasma, com o intuito de se avaliar o funcionamento dos sistemas de controle operacional do equipamento. / [en] This masters degree dissertation is focused on the methodological procedure for steel analysis in the chemical laboratory of CSTs steel making plant in order to certify the product and the process. In this procedure, spectrometry equipment is used based on the radiation emission of excited atoms present in plasma produced by electrical spark. The equipment is set to simultaneously analyze the contents of 18 elements present in a steel sample. The task is focused on the metrological reliability structure used by CSTs laboratory and mainly when it comes to the method validation procedure where the following performance characteristics were considered: Selectivity, Linearity, Detection Limit, Sensibility, Accuracy, Precision (repeatibility, reproducibility) and robustness, according to the INMETROs normative document (DOQ-CGCRE- 0008), thus showing that the method is adequate for its use. Special attention was given to the control parameters of the analytic equipment, based on basic principles of plasma spectrometry technique, in order to evaluate the functioning of the equipments operational control system.
787

[en] METROLOGICAL RELIABILITY OF HIGH FREQUENCY SURGICAL EQUIPMENT / [pt] CONFIABILIDADE METROLÓGICA DE UNIDADES ELETROCIRÚRGICAS DE ALTA FREQÜÊNCIA

ROSARIO DEL PILAR ALVA PALOMARES 28 March 2006 (has links)
[pt] A garantia da confiabilidade metrológica de equipamentos médicohospitalares, apesar de essencial para garantir a obtenção do efeito desejado e evitar efeitos adversos, em geral não é realizada durante o período de uso (pós-comercialização). Dentre as principais causas possíveis desta realidade se encontra a falta de informação por parte dos profissionais usuários quanto aos riscos, ou seja, a reduzida cultura metrológica no ambiente da saúde. A partir da identificação de alguns pontos vulneráveis e de graves repercussões na utilização inadequada de bisturis eletrônicos, esta dissertação avaliou parâmetros para a confiabilidade metrológica destes equipamentos, tanto em nível técnico e normativo, quanto em termos da utilização em ambientes hospitalar.Foi realizada uma busca e identificação da normalização nacional, e avaliada a abrangência das normas para garantir de forma completa a utilização dos equipamentos. Os trabalhos práticos para a avaliação metrológica das unidades eletrocirúrgicas foram realizados em três hospitais. Os resultados obtidos auxiliaram na avaliação da confiabilidade metrológica das unidades eletrocirúrgicas em uso, apontando para a necessidade não só de um controle metrológico periódico, como também da inserção de parâmetros de avaliação que não constam na norma aplicável ao equipamento em estudo. Parte desta dissertação foi financiada, através do Convênio referência FINEP n° 22.01.0692.00, pelo Programa Tecnologia Industrial Básica e Serviços Tecnológicos para a Inovação e Competitividade MCT/FINEP/FNDCT/Fundo Verde Amarelo, um programa cooperativo universidade-empresa. / [en] The metrological reliability of electromedical equipment, although essential in order to guarantee the desired effects and to avoid adverse effects, is often not verified after the equipment is sold and being used (post-sale period). This is partially due to the fact that, usually, health-care takers that use the equipment are unaware of the risks involved, in other words, there is a low metrological culture in the healthcare environment. In this dissertation, vulnerable aspects regarding the inadequate use of high frequency surgical equipment, also known as electrosurgical unit (ESU), were identified, and their consequences evaluated. Based on these results, technical and standard parameters important for the metrological reliability of ESUs, were evaluated. This dissertation also includes a detailed bibliographical research of basic principles, technical specifications, and international procedures that guarantee the metrological reliability of electrosurgical units. The scope of national standards was evaluated in order to guarantee the correct use of all of the ESU´s functions and modes. Experimental data for the metrological evaluation of the EUSs were collected in three (3) hospitals, one (1) private and two (2) public. The results are helpful for evaluating their metrological reliability, and indicate that not only that there is a need for a periodical metrological evaluation, but also that other parameters should be included in existing standards. Part of this dissertation was financed by the Convênio referência FINEP n° 22.01.0692.00 of the Programa Tecnologia Industrial Básica e Serviços Tecnológicos para a Inovação e Competitividade MCT/FINEP/FNDCT/Fundo Verde Amarelo, a universitycompany cooperative program.
788

Desenvolvimento de métodos e algoritmos para avaliação e otimização da confiabilidade em redes de distribuição / Development of methods and algorithms for evaluation and optimization of the reliability in networks distribution

Abaide, Alzenira da Rosa 17 June 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The distribution system is an extremely important part of the energy supply. At the same time, distribution networks, most of them with radial configuration, are much more vulnerable elements compared with transmission and sub transmission systems. The world experience shows that up to 80% of all interruptions in the energy supply are caused by failure in elements of the distribution systems. Naturally, a significant increase in reliability can be obtained through re-structuring of the distribution networks. This involves transformation of the traditional overhead networks into protected compact networks, duplication of energy supply alternatives for the consumers, duplication of the distribution transformers and wide use of network automation. All these alternatives demand massive investments. Another way of reliability improvement is related with the installation of commutation equipments. However, this solution should foresee a composition choice of types of equipment, the necessary amount and strategic location that all together can guarantee better results under the costbenefit point of view. The importance and efficiency of these solutions are confirmed through a large number of related researches accomplished in several countries. However, optimal installation of commutation equipments is an extremely complex problem. In the first place, it is necessary to define what means optimal degree of reliability, which is linked with the analysis of several possible formulations for the reliability optimization problem. In the second place, it is necessary to find out which characteristics can be used for reliability estimation and in what ways they should be implemented in the objective functions and restrictions along the process of reliability optimization. In the third place, through analysis of the available data existing in the electricity company, it is necessary to define if this information is sufficient for solution of the network optimal sectioning problem and what is the uncertainty level of this information. Finally, it should be chosen appropriate optimization methods, considering that researches show the impossibility of an efficient use of the linear and non linear programming methods taking into account characteristics of objective functions and restrictions. Furthermore, it is necessary not to forget that, most of the time, this problem should be solved in networks that already have commutation equipment installed. Therefore, usually, the optimization problem is addressed to redistribution of equipments already installed or the installation of additional equipments. This work is an attempt to find answers with respect to all these previously mentioned items, taking into account the operational conditions of the Brazilian electricity companies. / O sistema de distribuição é parte extremamente importante do fornecimento de energia. Ao mesmo tempo, as redes de distribuição, na maioria das vezes com configuração radial, são os elementos mais vulneráveis comparado com o sistema de transmissão e sub transmissão. A experiência mundial mostra que até 80% de todas as interrupções no fornecimento de energia são provocados por falhas nos elementos dos sistemas de distribuição. Naturalmente, que um aumento significativo na confiabilidade pode ser atingido através da reestruturação das redes de distribuição. Isto envolve as transformações das redes aéreas tradicionais para redes compactas protegidas, ou a duplicação das alternativas de suprimento de energia para os consumidores, através da instalação de dois transformadores de distribuição ou automatização completa das redes. Todas estas alternativas exigem investimento muito elevado. Outro meio de aumento da confiabilidade está relacionado com a instalação de equipamentos de comutação. Entretanto, esta solução deve prever a escolha da composição ótima de vários tipos de equipamentos, quantidade necessária e localização estratégica, que em conjunto podem garantir maior efeito sob o ponto de vista do custo-benefício. A importância e eficiência destas soluções estão confirmadas através do grande número de pesquisas realizadas em vários países. Entretanto este problema é extremamente complexo. Em primeiro lugar, é necessário definir o que significa nível ótimo de confiabilidade, o que está ligado com a análise das várias formulações possíveis do problema de otimização da confiabilidade. Em segundo lugar, é necessário encontrar quais características podem servir para a estimação da confiabilidade e de que forma elas devem ser implementadas na função objetivo e restrição no processo de otimização da confiabilidade. Em terceiro lugar, através da análise dos dados disponíveis na concessionária é preciso definir se a informação é suficiente para a solução do chaveamento ótimo e qual o nível de incerteza desta informação. E, por último, devem ser escolhidos os métodos adequados de otimização, considerando que as pesquisas mostram a impossibilidade do uso eficiente de métodos de programação linear e não linear, levando em conta as características da função objetivo e restrições do problema em análise. Além disso, é necessário não esquecer que na maioria das vezes este problema deve ser resolvido em redes que já possuem equipamentos de comutação instalados. Por isso, geralmente, o problema de otimização está direcionado para a redistribuição dos equipamentos já instalados ou a instalação de equipamentos adicionais. Neste trabalho é realizada a tentativa de encontrar as respostas em relação a todos os itens mencionados anteriormente, com base nas condições de operação das concessionárias brasileiras.
789

Otimização de políticas de manutenção em redes de distribuição de energia elétrica por estratégias híbridas baseadas em programação dinâmica / Maintenance policies optimization on electric power distribution networks by hybrid strategies based on dynamic programming

Bacalhau, Eduardo Tadeu, 1982- 27 August 2018 (has links)
Orientadores: Christiano Lyra Filho, Fábio Luiz Usberti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T03:25:56Z (GMT). No. of bitstreams: 1 Bacalhau_EduardoTadeu_D.pdf: 1630102 bytes, checksum: 258db7b09d8ce71b7d9a577e1993a3c2 (MD5) Previous issue date: 2015 / Resumo: Este trabalho explora alternativas para a determinação das melhores políticas de planejamento das ações de manutenção preventiva em redes de distribuição de energia elétrica. O problema é uma extensão de abordagens da área de manutenção centrada em confiabilidade (MCC), que vem sendo objeto de pesquisas ao longo das últimas décadas. Por se tratar de um problema de otimização combinatória de difícil solução, são poucos os artigos publicados que envolvem sistemas de escala real, e a maioria dentre esses utiliza meta-heurísticas como estratégia de solução. A abordagem desenvolvida neste trabalho é baseada na técnica de otimização denominada programação dinâmica. Duas estratégias para a redução do espaço de busca são adotadas: uma delas procura identificar e eliminar soluções dominadas; a segunda estratégia envolve a aplicação do processo de otimização da programação dinâmica em torno de uma vizinhança de uma solução promissora, movendo iterativamente em um espaço de soluções --- uma abordagem inspirada na programação dinâmica diferencial discreta. A combinação dessas duas estratégias é denominada Programação Dinâmica com Reduções de Espaço de Estados (PDREE). O trabalho investiga também a construção de estratégias híbridas. Uma das alternativas utiliza um algoritmo genético híbrido para a construção de planos de manutenção iniciais de boa qualidade, posteriormente otimizados pela PDREE. A segunda estratégia híbrida utiliza a PDREE para a construção de boas populações iniciais de soluções, posteriormente otimizada pelo algoritmo genético híbrido. As abordagens desenvolvidas são aplicadas a problemas de escala real e comparadas à abordagem por algoritmo genético híbrido. Os resultados mostram que as ideias desenvolvidas na tese estendem o estado-da-arte sobre a otimização de políticas de manutenção em redes de distribuição de grande porte / Abstract: This work explores alternatives to determine the best planning policies for preventive maintenance on electric power distribution systems. The problem is an extension of approaches of the reliability-centered maintenance area that has been studied allong the last decades. Since this problem is a hard combinatorial optimization problem, there are few works that address real-life systems, and most of these works use methods based on metaheuristic as solution strategy. The approaches proposed in this work are based on the optimization technique named dynamic programming. Two strategies are developed to reduce the search space of dynamic programming: the first strategy seeks to identify and eliminate dominated solutions; the second strategy confines the dynamic programming optimization procedures to the neighborhood of good solutions that move iteratively in the solution space---an approach inspired by the discrete differential dynamic programming method. The combination of both strategies is denominated Dynamic Programming with State Space Reductions (DPSSR). The work also investigates the development of hybrid strategies. One of the alternatives uses a hybrid genetic algorithm to obtain a promising initial maintenance strategy, further optimized by the DPSSR. The second hybrid strategy uses the DPSSR for constructing an initial good population, further optimized by a hybrid genetic algorithm. All the approaches are applied to real-life problems and compared to a pure hybrid genetic algorithm approach. The results show that the ideas developed in the thesis improve the state-of-the-art in obtaining the best maintenance policies for large distribution networks / Doutorado / Automação / Doutor em Engenharia Elétrica
790

Estudo dos principais parâmetros da confiabilidade de falha por fadiga de riser marítimo de perfuração / Study of the main parameters of the fatigue reliability failure in marine drilling riser

Chagas, Bruno Luiz Barbosa das, 1986- 30 August 2018 (has links)
Orientador: Celso Kazuyuki Morooka / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-30T02:08:44Z (GMT). No. of bitstreams: 1 Chagas_BrunoLuizBarbosadas_M.pdf: 3797109 bytes, checksum: 1ef50f3d002aa234dbe301fd26044c8f (MD5) Previous issue date: 2015 / Resumo: O presente trabalho tem como objetivo principal avaliar a probabilidade de falha por fadiga em um riser de perfuração. Os parâmetros mais importantes são identificados e sua influência na probabilidade de falha é analisada. De acordo com as premissas do comportamento dinâmico de um riser, a partir do qual se obtém o dano total à fadiga, juntamente com a teoria da confiabilidade e as variáveis de incerteza, aplicou-se o método FORM (First Order Reliability Method) determinando-se a probabilidade de falha por fadiga em um riser. O procedimento foi adotado para um campo marítimo em operação, a fim de se demonstrar a sensibilidade das variáveis envolvidas na função de estado limite. Neste estudo consideraram-se o expoente m da curva S-N e a constante K da curva S-N como sendo ora determinísticos ora probabilísticos. Assim sendo, a partir das premissas e procedimentos acima elencados, os resultados de probabilidade de falha para análise probabilística se mostraram mais sensíveis que a análise determinística nas quatro diferentes localizações críticas ao longo do comprimento do riser de perfuração / Abstract: The primary objective of this work is to evaluate the probability of fatigue failure in a drilling riser. Key parameters are identified and their influence on the probability of failure is analized. Based on riser dynamic behavior, which givestotal fatigue damage, along with the reliability theory and the variables of uncertainty, the method FORM (First Order Reliability Method) was applied to determine the probability of fatigue failure on a riser . The procedure was applied in a offshore field in operation in order to demonstrate the sensitivity of the variables involved in the limit state function.In this study the exponent m of the SN curve and the constant K of SN curve were considered to be either deterministic or probabilistic. Thus, according to adopted assumptions and procedures, the results of probability of failure for probabilistic analysis have shown to be more sensitive than deterministic analysis in the four different critical locations along the length of the drilling riser / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo

Page generated in 0.0478 seconds