• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1965
  • 16
  • 13
  • 12
  • 8
  • 7
  • 7
  • 7
  • 5
  • 3
  • 2
  • 1
  • Tagged with
  • 2044
  • 1009
  • 666
  • 590
  • 501
  • 427
  • 416
  • 283
  • 278
  • 276
  • 265
  • 255
  • 226
  • 223
  • 214
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1131

Purificação de anticorpo monoclonal anti-Trypanosoma cruzi do isotipo IgG2a em OPS-agarose / IgG2a isotype anti-Trypanosoma cruzi monoclonal antibody purification onto OPS-agarose

Oliveira, Carla Reis, 1985- 25 August 2018 (has links)
Orientador: Sônia Maria Alves Bueno / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-25T04:00:44Z (GMT). No. of bitstreams: 1 Oliveira_CarlaReis_M.pdf: 2012737 bytes, checksum: 29446d9a4e9ff14301c100dcd3fb82ab (MD5) Previous issue date: 2014 / Resumo: Anticorpos monoclonais (AcM) são imunoglobulinas secretadas por clones de linfócitos B imortalizados obtidos pela tecnologia de hibridomas. Esses clones são cultivados em meios de cultura complexos e, geralmente, liberam baixas concentrações de AcM, dificultando as etapas de purificação. Como a utilização destas proteínas nas áreas terapêutica e analítica requer um alto grau de pureza, diferentes estratégias de purificação vêm sendo desenvolvidas, mas usualmente os anticorpos são purificados por cromatografia de afinidade com proteína A ou G imobilizada, o que representa um elevado custo de produção para processos industriais. No intuito de contribuir para o desenvolvimento de processos de purificação dessas moléculas, estudou-se a purificação do AcM anti-Trypanosoma cruzi isotipo IgG2a em orto-fosfo-serina (OPS) imobilizado em gel de agarose. Contrário ao relatado em literatura, observou-se que o agente quelante apresentou baixa capacidade em imobilizar o íon metalico Ni2+. Além disso, o quelato formado adsorveu a molécula alvo juntamente com impurezas do sobrenadante do meio de cultura. Foi observado também que o OPS se comporta como ligante de troca iônica seletivo para IgG2a em solução tampão Tris-HCl 50 mmol/L pH 7,0, quando imobilizado em gel de agarose ativado com CNBr, porém os ensaios realizados com o ligante imobilizado em gel ativado com bisoxirano demonstraram que a inserção de uma molécula espaçadora reduz a seletividade do adsorvente. O AcM foi recuperado com elevado grau de pureza quando empregado em solução tampão Tris-HCl 50 mmol/L pH 7,0 e dessorção pelo acréscimo de NaCl 1,0 mol/L para promover aumento da força iônica. Os resultados de ensaios dinâmicos revelaram que a eficiência de recuperação do produto foi de 97,3% e a capacidade dinâmica de adsorção foi 0,39 mg de AcM/mL de gel devido. Este trabalho sugere a potencialidade de utilização do ligante OPS para a purificação dos anticorpos anti-Trypanosoma cruzi (IgG2a) / Abstract: Monoclonal antibodies (mAb) are immunoglobulins produced by lynphocyte B clones immortalized by the hibridoma technology. Those clones are cultivated in complex medium and generally produce low levels of mAb, interfering on purificaton steps. Since these antibodies are required for analytical and therapeutical purposes, the need of highly pure antibodies is imperative. Although they are usually purified by chromatografic techniques utilizing immobilized protein A ligands, different strategies for downstream processes have been studied to overcome the high costs of these conventional medias for industrial scale purposes. Aiming to contribute with the development of such processes, the anti-Trypanosoma cruzi mAb (IgG2a isotype) was investigated under chromatographic conditons twards the affinity ligand ortho-phospho-L-serine (OPS) immobilized onto agarose beads. It was observed that despite the fact this ligand has been reported as a chelating agent for the purification of immunoglobulins by IMAC technique, OPS presented low chelating capacity for Ni2+ and the metal complex formed adsorbed the desired protein within culture medium contaminants. It was also observed that under buffering conditions of Tris-HCl 50 mmol/L pH 7.0 OPS behaves as a selective ionic exchanger ligand for IgG2a when immobilized in CNBr activated agarose. On the other hand, when immobilized in bisoxirane activated agarose, OPS has shown that the presence of a spacer arm reduces the selectivity of the adsorbent. The mAb was recuperated in one single step with highly putity degree when operated with adsorption buffer Tris-HCl 50 mmol/L pH 7.0 and elution by increasing the ionic strength with the addition of NaCl 1.0 mol/L. The dynamic tests results showed that the efficiency for product recovery was 97.3% and the dynamic binding capacity was 0.39 mg of mAb/mL swollen agarose. This work suggests the potencial use os OPS ligand affinity for the purification of IgG2a antibodies anti-Trypanosoma cruzi in a single step / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestra em Engenharia Química
1132

Estudo termodinâmico da separação do ibuprofeno racêmico por cromatografia líquida quiral utilizando a fase estacionária tris (3,5-dimetilfenilcarbamato) de celulose / Thermodynamic study of the racemic ibuprofen separation in chiral liquid chromatography using the cellulose tris(3,5 dimethylphenylcarbamate) stationary phase

Ferrari, Wilson Murilo Correa da Silva, 1987- 26 August 2018 (has links)
Orientador: Marco Aurélio Cremasco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-26T01:42:10Z (GMT). No. of bitstreams: 1 Ferrari_WilsonMuriloCorreadaSilva_M.pdf: 1651565 bytes, checksum: 0f832d37a7639460ca0f629ffdc222f7 (MD5) Previous issue date: 2014 / Resumo: O ácido (RS)-2-(4-(2-metilpropil)fenil)propanoico, conhecido como ibuprofeno, é um importante fármaco anti-inflamatório não esteroidal, também notório por suas propriedades analgésicas e antipiréticas. A droga é comercializada em sua forma racêmica, no entanto em alguns países é empregado apenas o S-(+)-ibuprofeno que detém o princípio ativo. Além disso, o R-(-)-ibuprofeno provoca toxicidade devido à formação de triglicerídeos híbridos no organismo humano. Substâncias que desempenham funções biológicas no corpo necessitam de métodos eficazes de separação e purificação. Os métodos cromatográficos se apresentam como uma alternativa para obter as formas isoladas de enantiômeros com elevado grau de pureza. No presente trabalho, estudou-se estabelecer condições necessárias para a separação eficaz em escala analítica por meio da abordagem termodinâmica do fenômeno. A separação foi realizada com o método direto empregando uma coluna quiral recheada com sílica recoberta por tris (3,5-dimetilfenilcarbamato) de celulose. A fase móvel composta por n-hexano e isopropanol na proporção 99/1 foi definida com base nos parâmetros cromatográficos seletividade e resolução. O aditivo ácido trifluoracético também foi utilizado na fase móvel para melhorar a definição dos picos cromatográficos. Após a determinação das fases estacionária e móvel, iniciou-se a caracterização da adsorção envolvida na separação. A ordem de eluição dos enantiômero foi verificada por dicroísmo circular e polarimetria, desta forma constatou-se que o S-(+)-ibuprofeno é o composto mais retido. A porosidade total foi determinada com o método do primeiro momento utilizando o 1,3,5-tri-terc-butilbenzeno, um composto pequeno o suficiente para se difundir tanto entre as partículas do leito quanto em seus interstícios. O valor obtido foi de 0,647. A abordagem do primeiro momento do pulso cromatográfico também possibilitou a determinação da constante de equilíbrio de adsorção para cinco temperaturas entre 15 °C e 35 °C. Neste estudo utilizou-se a porosidade total e o comprimento do leito como parâmetros do método para realizar a linearização do tempo de retenção versus o inverso velocidade da fase móvel. Por fim, os parâmetros entálpicos e entrópicos de adsorção foram calculados por meio da abordagem cromatográfico da equação de van¿t Hoff. Este equacionamento possibilitou definir o fenômeno como endotérmico, no qual ocorreu adsorção física. O composto mais retido apresentou valor de 8,76 kJ mol-1 para a variação de entalpia, enquanto o R-(-)-ibuprofeno 7,21 kJ mol-1. A temperatura isoenantiosseletiva calculada foi 237,38 K / Abstract: The (RS)-2-(4-(2-methylpropyl)phenyl) propanoic acid, known as ibuprofen, is an important non-steroidal anti-inflammatory drug, notorious for its analgesic and antipyretic properties. The drug is commercialized in its racemic form. However in some countries only the S-(+)-ibuprofen is used, which it is the active isomer. Since the R-(-)-ibuprofen is toxic due to forms hybrid triglycerides in the human body. Substances with biological functions in the body must undergo effective methods of separation and purification. Chromatographic methods are an alternative for the separation of enantiomers with high purity. In the present study the necessary conditions for effective separation in analytical scale by means of thermodynamic approach of the phenomenon was studies. The separation was carried out employing a chiral column packed with silica coated with cellulose tris (3,5-dimethylphenylcarbamate). The mobile phase consisting of n-hexane and isopropanol in ratio 99/1 was defined on the basis in chromatographic parameters as selectivity and resolution. The trifluoroacetic acid additive also was used on the mobile phase to improve the resolution of the chromatographic peaks. After the determination of stationary and mobile phases, the characterization the adsorption involved in the separation was studies. The order of elution of the enantiomers was checked by circular dichroism and polarimetry. It was observed that the S-(+)-ibuprofen is the most retained compound. The total porosity was determined by first moment using 1,3,5-tri-tert-butylbenzene. This molecule is small enough to diffuse through the bed particles, but also the between the particles interstices. The value obtained was 0,647. The approach of first moment of the chromatographic pulse also allowed the determination of the adsorption equilibrium constant for five temperatures between 15 °C and 35 °C. In this study, the bed void and bed length were used as input parameters in the perform linearization of retention time versus the mobile phase inverse velocity. Finally, the enthalpy and entropy of adsorption were calculated by means of chromatographic approach usual the van't Hoff equation. The adsorptions of enantiomers were endothermic. Both molecules adsorbed physically. The enthalpy of the most retained compound was 8,76 kJ mol-1 and 7,21 kJ mol-1 for R-(-)-ibuprofeno. The enantioselective temperature was 237,38 K / Mestrado / Engenharia de Processos / Mestre em Engenharia Química
1133

Desenvolvimento e validação de metodologia analitica, utilizando a CLAE, para determinação de vitamina C em frutas e seus principais produtos / Development and validation of analytical methodology, using the HPLC for determination of vitamin C in fruits and its main products

Aldrigue, Mauro Luiz 26 August 2018 (has links)
Orientador: Helena Teixeira Godoy / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-26T04:11:35Z (GMT). No. of bitstreams: 1 Aldrigue_MauroLuiz_D.pdf: 4824419 bytes, checksum: ad7cda2a5f6c5f9480fcf5bcc909dd80 (MD5) Previous issue date: 1998 / Resumo: Atualmente, a vitamina C é a mais importante dentre as vitaminas comercializadas. Destaca-se por sua eficiente ação antioxidante, empregada em alimentos e seu largo uso como fármaco. Entre os compostos que apresentam esta atividade vitamínica, o ácido L-ascórbico (AA) é a forma mais difundida e comercializada, embora o produto de sua oxidação, o ácido desidroascórbico (DHAA) possua a mesma atividade vitamínica. Já, com cerca de 5% desta atividade, o ácido isoascórbico (IAA) é adicionado a vários alimentos, o, que leva a necessidade de métodos eficientes também para o seu controle. Para melhor avaliar o potencial vitamínico de fontes naturais de vitamina C, que são as frutas, os legumes e seus produtos, busca-se desenvolver métodos que determinem simultaneamente estas formas ativas, o que constitue em um dos grandes desafios metodológicos na atualidade. Assim, a metodologia para análise das formas ativas de vitamina C (AA, DHAA e lAA) foi estabelecida com a técnica de Cromatografia Líquida de Alta Eficiência (CLAE), utilizando coluna Spherisorb ODS-2, 5Jµm,150x4,6mm, fase móvel aquosa com 2,5mmol/L de cetrimida e 25mmol/L de acetato de amônia, pH 5,60 ajustado com ácido acético e vazão de 0,80mL/min, utilizando detector de arranjo de diodos, operando a 263nm. A quantificação foi feita por padronização externa, através das curvas analíticas. Os limites de detecção e quantificação estabelecidos foram de 0,5Jµg/mL e 1,0µg/mL, respectivamente, tanto para o AA DHAA e lAA. As taxas de recuperação foram de 97,8; 98,8 e 117,1% para o AA DHAA e lAA, respectivamente. Os testes de repetibilidade apresentaram coeficientes médios de variação abaixo de 6,0%. Concomitantemente, uma outra condição cromatográfica de análise foi desenvolvida, com os mesmos objetivos, empregando uma coluna PLRP-S, 5µm,100A, 250x4,6mm, fase móvel aquosa com 250mmol/L de NaH2P04,pH 3,30, ajustado com HCl, vazão de 0,50mL/min, utilizando o mesmo sistema de detecção. Os limites de detecção e quantificação, para esta nova condição, foram 0,35µg/mL e 1,0µg/mL, respectivamente para todas as formas de vitamina C estudadas e os coeficientes de variação abaixo de 10,0%. Para a detecção de DHAA, em ambas as condições, foi utilizada a reação com DL-homocisteína e a quantificação por diferença entre duas injeções. Estudou-se também a reação do DHAA com o-fenilenodiamina (o-PDA), para detecção em uma única injeção, porém obteve-se menor sensibilidade e maior tempo de reação. Na aplicação em amostras optou-se pela metodologia desenvolvida com coluna C18, principalmente por apresentar uma melhor resolução e um menor custo. O método foi aplicado na determinação de vitamina C total (AA e DHAA) em caju, cujo teor variou de 207,0 a 300,8mg/l00g em frutos maduros. Nos produtos de caju a concentração variou entre 148,5 a 243,0mg/100g em sucos comerciais; 118,0mg/100g em polpa congelada comercial; 229,0 a 318,5mg/100g em polpa congelada artesanal; e 170,7mg/100g em néctar. Os frutos de acerola apresentaram teores médios de 1229,2mg/100g em frutos maduros a 3498,lmg/100g em frutos verdes. Nos sucos comerciais os valores obtidos variaram de 710,0 a 881,2mg/100g; 1141,1 a 1375,2mg/100g na polpa congelada comercial e 282,3mg/100g no néctar. Outras matérias-primas também tiveram seu teor de vitamina C determinado, como uva e suco de uva comercial, goiaba vermelha, ameixa, figo-da-índia e beterraba. O DHAA foi detectado exclusivamente em ameixa e uva niágara e com teor elevado em frutos de caju (45,7%) e frutos maduros de acerola (20,7%). Os resultados foram comparados com o método oficial de titulação com 2,6-dicloroindofenol. O estudo de validação do método desenvolvido com a coluna C18, apresentou resultados bastante satisfatórios para recomendá-Io na aplicação da determinação de vitamina C em trutas e seus produtos, além de oferecer duas vantagens em relação ao método oficial: não apresenta interferência em matrizes coloridas e possibilita a determinação do DHAA, que é imprescindível em alguns casos / Abstract: Currently, amongst commercially available vitamins, vitamin C is the most important. Due to its efficient antioxidant action, it is used in foods and widely in farmaceuticals. Of the substances which present this vitaminic activity, L-ascorbic acid (AA) is a well known and commercialized form, though its oxidation product, dehydroascorbic acid (DHAA) possesses the same amount of antiascorbutic action. Isoascorbic acid (IAA) which possesses about 5% of this activity is added to various foods, thus requiring efficient methods for its control. To better evaluate the vitaminic potential of the natural sources of vitamin C, i.e. fruits, legumes and their products, the need to develop methods which could simultaneously determine these active forms imposes a great methodological challenge. Thus, a methodology for the analysis of the various active forms of vitamin C (AA, DHAA, IAA) was developed, using a High Performance Liquid Chromatography (HPLC) technique, and using a Spherisorb ODS-2 column, 1,5µm particle size, 15cmx4.6mm i.d. The aquous mobile phase was 2.5mmol/L of cetrimide and 25mmol/L of ammonium acetate, pH 5.60 adjusted with acetic acid and a flow rate of 0.8mL/min, using a diode array detector (DAD) operating at 263nm. Quantitative data were obtained using calibration curves constructed by plotting peak area versus concentration. Detection and quantification limits were 0.5 and 1.0µg/mL for AA, DHAA and IAA, respectively. The recovery was 97.8% for AA, 98.8% for DHAA and 117.1% for IAA. Reapeated injections showed a relative standard deviation lower than 6.0%. Concomitantly, another method was also developed, with the same objectives, with a PLRP-S column, 5µm particle size, 100A pore size, 25cmx4.6mm i.d., mobile phase of 250mmol/L NaH2P04, pH 3.30 adjusted with HCI, flow rate of 0.50mL/min and DAD (?=263nm). Detection and quantification limits were 0.35µg/mL and 1.0µg/mL respectively. The relative standard deviation was lower than 10.0%. For the detection of DHAA, in both methods, the reaction with DL-homocistein was used and quantification by difference, using two injections. A reaction of DHAA with o-phenylenediamine (o-PDA) was also studied, for detection with single injection, but with lower sensitivity in the UV detection and a reaction which consumed much time. For application in the samples we opted for the methodology developed using the CI8 column, mainly for presenting a better resolution and being less expensive. The determination of total vitamin C (AA and DHAA) was carried out in cashew fruit, which varried from 207.0 to 300.8mg/100g in mature fruits and 148.5 to 243.0mg/100g in commercial juices. Commercial frozen cashew pulp presented 118.0mg/100g and artesanal pulp 229.0 to 318.5mg/100g, while a nectar presented 170.7mg/100g. The West Indian cherry fi-uitspresented a variation trom 1229.2mg/100g in mature fruits to 3498.1mg/100g in green fruits. Commercial juices varried trom 710.0 to 881.2mg/100g; frozen commercial pulp from 1141.1 to 1375.2mg/100g and nectar 282.3mg/100g. Vitamin C was determined in other samples: grape, grape juice, prune, red guava, figo-da-Índia and beeroot. DHAA was only detected in prune and niagara grapes and at higher concentrations in cashew fruits (45.7%) and mature West Indian cherry fruits (20.7%). The results were compared with the official method of titration with 2,6- dichloroindophenol. The study of the validation of the method developed with the C18 column, presented satisfactory results thus being recommended for the determination of vitamin C in fruits and their products, besides offering the advantages in relation to the method of AOAC in matrixes which present interference with the color during titration, and it also offers the possibility of determining of DHAA, which is necessary in some cases / Doutorado / Doutor em Ciência de Alimentos
1134

Resíduos de antibióticos tetraciclínicos em músculo de peixe : comparação de diversos métodos de extração e avaliação por HPLC / Tetraciclinics antibiotics residues in fish muscle : comparison of various methods of extraction and evaluation by HPLC

Orlando, Eduardo Adilson, 1984- 22 August 2018 (has links)
Orientador: Ana Valéria Colnaghi Simionato Cantú / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T23:35:40Z (GMT). No. of bitstreams: 1 Orlando_EduardoAdilson_M.pdf: 785459 bytes, checksum: 50e5f02a98813d34ba94c694183e9030 (MD5) Previous issue date: 2013 / Resumo: A classe de antibióticos tetraciclinas é amplamente empregada na aquicultura e possui especial dificuldade analítica devido a uma estrutura complexa e grande interação com os componentes da matriz cárnea. Neste trabalho foram avaliadas diferentes técnicas de extração de resíduos de tetraciclinas em filés de tilápias. Analisou-se oxitetraciclina, doxiciclina, tetraciclina e clortetraciclina por HPLC-fluorescência nas condições: gradiente de fase móvel, com fase orgânica composta por MeOH:ACN (1:1, v/v) e fase aquosa pH 7,00 contendo Na2COOH (37,5 mmol L), CaCl2 (17,5 mmol L) e EDTA (12,5 mmol L) e detecção em 385/528 nm (lexc/lem). Foram avaliados os métodos de extração: partição líquido-líquido; extração em fase sólida utilizando as fases estacionárias fenil, C18 e polimérica Oasis-HLB; concentração em resina XAD 16; e QuEChERS; que foram otimizados utilizando planejamento experimental fatorial fracionário e comparados quanto à eficiência de extração. A partição líquido-líquido e o protocolo QuEChERS apresentaram baixas eficiências de extração dos analitos (14-30%). O emprego da resina polimérica Amberlite XAD 16 apresentou boa eficiência (40-60%), mas com baixa precisão e grande consumo de tempo. O emprego de SPE apresentou os melhores resultados, com destaque para a fase fenil (58-76%), sendo então este método validado com relação as figuras de mérito seletividade, linearidade, exatidão, precisão, limite de detecção e quantificação, mostrando-se adequado para a investigação dos analitos em níveis de resíduos em filés de tilápia. Um total de 26 amostras comerciais foram analisadas, sendo que apenas uma delas apresentou resíduo de 42,0 ± 8,4 ng g de Oxitetraciclina, estando abaixo do limite máximo de resíduo no estabelecido no Brasil de 200 ng g / Abstract: The indiscriminate use of antibiotics in aquaculture can generate residues in meat intended for human consumption and cause the arising of bacterial resistance. The tetracycline antibiotics class is widely used and has ultimate analytical difficulties due to a complex structure and large interaction with components of meat matrix. In this work different techniques were evaluated for extraction of tetracycline residues in tilapia fillets. Oxytetracycline, doxycycline, tetracycline and chlortetracycline were analyzed by HPLCfluorescence under the following conditions: mobile phase gradient; organic phase composed by MeOH:ACN (1:1, v/v) and aqueous phase containing Na2COOH (37,5 mmol L), CaCl2 (17,5 mmol L) e EDTA (12,5 mmol L) at pH 7.00 and detection at 385/528 nm (lexc/lem). The evaluated extraction methods were: liquid-liquid partition; solid phase extraction (SPE) using stationary phases phenyl, C18 and Oasis HLB; concentration on adsorbent resin XAD 16; and QuEChERS. The methods were optimized using fractional factorial experimental design and compared in terms of extraction efficiency. The liquidliquid partition and QuEChERS protocol showed low extraction efficiencies (14-30%). The use of polymeric resin Amberlite XAD 16 showed a good efficiency (40-60%) but with low precision and large time consumption. The use of SPE showed the best results and was validated according to the merit figures selectivity, linearity, accuracy, precision, limit of detection and quantification, making it adequate for the investigation of analytes at levels of residues in tilapia fillets. A total of 26 real samples were analyzed and only one sample exhibited Oxytetracycline residue of 42,0 ± 8,4 ng g, being below the maximum residue limit established in Brazil of 200 ng g / Mestrado / Quimica Analitica / Mestre em Química
1135

Separação cromatográfica dos enantiômeros do fármaco verapamil em processo contínuo multicolunas / Chromatographic separation of verapamil enantiomers in multicolumn continuous process

Perna, Rafael Firmani, 1985- 23 August 2018 (has links)
Orientadores: Cesar Costapinto Santana, Marco Aurélio Cremasco / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-23T03:10:20Z (GMT). No. of bitstreams: 1 Perna_RafaelFirmani_D.pdf: 3196327 bytes, checksum: 4240581b6c5c11e40e59fac8ddddd657 (MD5) Previous issue date: 2013 / Resumo: O fármaco racêmico verapamil tem sido utilizado no tratamento de doenças cardiovasculares relacionadas à hipertensão arterial, arritmias supraventriculares e angina pectoris. Seus enantiômeros apresentam biodisponibilidades distintas e exibem diferentes propriedades farmacológicas. O enantiômero S-(-)-verapamil apresenta maior potencial cardiovascular quando comparado ao seu antípoda óptico R-(+)-verapamil; este, por sua vez, exibe ação antitumoral, atuando como inibidor hepatocarcinogênico. Diante deste contexto, o presente trabalho teve como objetivo a determinação de parâmetros envolvidos na separação dos enantiômeros do fármaco em escala semi-preparativa visando obtê-los, opticamente puros, em unidade cromatográfica contínua do tipo leito móvel simulado. O desenvolvimento da separação ocorreu em colunas quirais recheadas com fase estacionária tris (3,5-dimetilfenilcarbamato) de amilose utilizando a mistura de n-hexano, isopropanol, etanol e dietilamina (90: 5: 5: 0,1 %, em volume) como fase móvel. Experimentos de pulsos com soluções diluídas dos enantiômeros do verapamil foram realizados para diferentes temperaturas (15 a 35 ºC) e vazões (1,0 a 2,5 mL min-1) visando determinar as constantes de equilíbrio de adsorção (constantes de Henry) e os parâmetros cromatográficos, termodinâmicos e de transferência de massa; ao passo que, experimentos com soluções diluídas dos traçadores (compostos inertes) foram realizados para se obter as porosidades do sistema. Os fatores de retenção apresentaram valores considerados ideais para separações enantioméricas (2,0 < k < 6,0) para vazões e temperaturas avaliadas. Com relação à seletividade e resolução cromatográficas, foram obtidos valores de 1,34 e 1,70, respectivamente, para temperatura de 25 ºC e vazão de 1,0 mL min-1, o que comprova a completa separação dos enantiômeros na coluna semi-preparativa. As constantes de Henry apresentaram-se relativamente elevadas, sendo que o enantiômero R-(+)-verapamil apresentou maior afinidade pela fase estacionária com maiores valores para a constante de equilíbrio de adsorção. O coeficiente de dispersão axial sofreu pouca variação entre os enantiômeros; entretanto, o coeficiente de transferência de massa global foi considerado relativamente rápido com valores superiores a 65,70 e 45,32 min-1 para os enantiômeros S-(-) e R-(+), respectivamente. Os parâmetros termodinâmicos confirmaram a maior afinidade do R-(+)-verapamil pela coluna quiral com maiores valores negativos de entalpia de adsorção. Constatou-se também que os fenômenos entálpicos regem a separação enantiomérica na fase estacionária avaliada. Experimentos com soluções concentradas da mistura racêmica foram realizados com a finalidade de se determinar as isotermas de adsorção competitivas e os perfis de eluição sob condições de sobrecarga da coluna cromatográfica. As isotermas de adsorção apresentaram comportamento não-linear para a faixa de concentração utilizada e foram satisfatoriamente ajustadas ao modelo de Langmuir Competitivo Modificado. O estudo de sobrecarga mostrou a possibilidade da separação do verapamil racêmico nas escalas semi-preparativa e preparativa. Finalmente, foram determinados os parâmetros operacionais do processo contínuo multicolunas para os modos VARICOL® e LMS e, obtidos os valores das variáveis de desempenho (pureza, produtividade, recuperação e consumo de solvente) das respectivas unidades. Os resultados obtidos mostraram-se promissores à separação dos enantiômeros do verapamil e, de fato, representaram o primeiro conjunto de dados experimentais em escala mundial decorrentes do uso da cromatografia contínua operada em leito móvel simulado / Abstract: The racemic drug verapamil has been used in the treatment of cardiovascular diseases related to hypertension, supraventricular arrhythmias, and angina pectoris. Its enantiomers have different bioavailability and pharmacological properties. The S-(-)-verapamil presents more cardiovascular potential when compared to its optical antipode R-(+)-verapamil. This, in turn, exhibits antitumor activity, acting as a hepatocarcinogenic inhibitor. Given this context, the present study aimed to determine the parameters involved in the separation of the enantiomers of the drug in semi-preparative scale in order to obtain them, optically pure, in continuous chromatographic unit type simulated moving bed. The development occurred in separation columns packed with chiral stationary phase amylose tris (3,5-dimethylphenylcarbamate) using a mixture of n-hexane, isopropanol, ethanol, and diethylamine (90: 5: 5: 0.1 %, by volume) as mobile phase. Pulse experiments with dilute solutions of the verapamil enantiomers were performed at different temperatures (15 to 35 ºC) and flow rates (1.0 to 2.5 mL min-1) to determine the equilibrium constants adsorption (Henry's constants) and chromatographic, thermodynamic, and mass transfer parameters; whereas experiments with dilute solutions of the tracers (inert compound) were performed to obtain the porosity of the system. The capacity factors had values considered ideal for enantiomeric separations (2.0 < k < 6.0) for the flow rate and temperature evaluated. Regarding the chromatographic selectivity and resolution values of 1.34 and 1.70 were obtained, respectively, for temperature of 25 ºC and flow rate of 1.0 mL min-1, which proves the complete separation of the enantiomers in the semi-preparative column. Henry's constants were relatively high, and the R-(+)-verapamil had a higher affinity for the stationary phase with the highest values for the adsorption equilibrium constant. Axial dispersion coefficient showed little variation between the enantiomers; however, the overall mass transfer coefficient was considered relatively fast to values of 65.70 and 45.32 min-1 to S-(-) and R-(+) enantiomers, respectively. Thermodynamics parameters confirm the major affinity of R-(+)-verapamil with high negative values of adsorption enthalpy. It was also found that the enthalpic phenomena govern the enantiomeric separation. Experiments with concentration solutions of the racemic mixture were conducted in order to determine the competitive adsorption isotherm, and the elution profiles under overload conditions of the chromatographic column. The competitive isotherms showed a nonlinear behavior to the range of concentration investigated and the Langmuir Competitive Modified model represents satisfactorily the adsorption data. The study of overload of the column carried through in high concentration showed the possibility of the separation of racemic verapamil using semi-preparative and preparative scale. Finally, the operating parameters of the multicolumn continuous process (VARICOL® and LMS units), and the values of the performance variables (purity, productivity, recovery, and solvent consumption) were determined. The results obtained were promising to the separation of the verapamil enantiomers and, in fact, represented the first set of experimental data worldwide from the use of the continuous chromatography operated in simulated moving bed / Doutorado / Desenvolvimento de Processos Biotecnologicos / Doutor em Engenharia Química
1136

Determinação de folatos em feijão / Determination of folate in beans

Cunha, Elenice Carla Emídio, 1986- 09 June 2013 (has links)
Orientador: Helena Teixeira Godoy / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-23T11:39:02Z (GMT). No. of bitstreams: 1 Cunha_EleniceCarlaEmidio_M.pdf: 877481 bytes, checksum: 0115f62caab877a3e3e74dfe26ca0466 (MD5) Previous issue date: 2013 / Resumo: No Brasil, o feijão obteve ampla difusão cultural e atualmente o país é considerado o maior produtor e consumidor do grão. Essa leguminosa é citada internacionalmente como uma fonte de folatos, um grupo de vitaminas pertencentes ao complexo B. Entretanto, é quase inexistente o levantamento de dados sobre o teor de folatos em feijões brasileiros. Os folatos participam de dois processos biológicos importantes: o ciclo de metilação, que consiste na transferência de carbonos e a biossíntese do DNA, fundamental para a manutenção das células. Sua deficiência está relacionada a problemas na formação do tubo neural em fetos, doenças cardiovasculares e alguns tipos de câncer. Deste modo, torna-se necessário um método eficiente para detectar e quantificar os folatos presentes nas diferentes variedades de feijão consumidas no país. O objetivo do trabalho foi determinar o teor de folatos por cromatografia líquida de alta eficiência (CLAE), utilizando diferentes métodos de hidrólise enzimática, além de aplicar o método em quatro variedades de feijão comum (carioca, preto, vermelho e branco) e uma variedade de feijão de corda, avaliando o efeito do cozimento sobre os folatos presentes. Em comparação como os outros tratamentos, apenas o tratamento tri-enzimático foi mais eficiente na identificação e quantificação dos folatos. Nos feijões, foram detectatos somente o tetraidrofolato (THF) e o 5-metiltetraidrofolato (5-MTHF). Os folatos foram separados utilizando uma coluna C18 como fase estacionária, solução acidificada com ácido acético/acetonitrila como fase móvel, e detectados por fluorescência (?exc. 290 nm e ?emis 360 nm). Os limites de detecção e quantificação foram, respectivamente, 0,9 ng/mL e 5,4 ng/mL para o THF, e 0,7 ng/mL e 4,2 ng/mL para o 5-MTHF. O método apresentou linearidade na faixa de trabalho, além de repetitividade e reprodutibilidade. Nos feijões crus o teor de THF variou de 20,3 a 1484 µg/100g e o teor de 5-MTHF variou de não determinado a 60 µg/100g. Já nos feijões cozidos, que foram processados de acordo com a recomendação dos fabricantes, o teor de THF variou de 15,3 a 1207 µg/100g, e de 5-MTHF variou de não determinado a 31,3 µg/100g. Observou-se que as perdas por processamento foram significativas e diferentes entre as variedades de feijões, sendo o 5-MTHF o composto mais suceptível. Além disso, as perdas foram ainda maiores quando o feijão foi submetido ao remolho antes do cozimento, como no feijão branco. No feijão de corda foram encontrados os maiores teores de folatos, embora tenha sido encontrado apenas o THF. Houve diferenças significativas entre os três lotes de cada variedade, que pode ser devido à diversidade das condições de cultivo e variação de genótipos do feijão. Os dados mostram que o feijão brasileiro é uma boa fonte de folatos presentes na dieta / Abstract: The beans have been widespread used as a traditional food in Brazil and nowadays the country is the largest producer and consumer of this grain. This legume is referred internationally as a source of folates, which belong to the group of vitamins B complex. However, the data about folates from Brazilian beans are almost nonexistent. Folates take part in two important biological processes: the methylation cycle, that is the transfer of carbon, and the biosynthesis of the DNA, essential for cell maintenance. The folates deficiency is related to problems in neural tube formation in fetuses, cardiovascular disease and some cancers. Thus, it becomes necessary to develop an efficient method for detecting and quantifying folate present in different varieties of beans consumed in Brazil. The aim of this study was to determine the content of folates by high performance liquid chromatography (HPLC), using different enzymatic hydrolysis methods, and apply the method on four common bean (carioca, black, white and red) and a cowpea, as well as evaluating the effect of cooking process on the content of folates. The tri-enzyme treatment compared to other treatments was the most efficient for identification and quantification of the folates. Only the tetrahydrofolate (THF) and 5-methyltetrahydrofolate (5-MTHF) were detected in the beans. Folates were separated using a C18 column as the stationary phase, acidified solution with acetic acid/acetonitrile as the mobile phase, and were detected by fluorescence (290 nm and ?exc. ?emis 360 nm). The limits of detection and quantification were, respectively, 0.9 ng/mL and 5.4 ng/mL for THF, and 0.7 ng/mL and 4.2 ng/mL for 5-MTHF. The method was linear in the working range including repeatability and reproducibility. In raw beans the THF content ranged from 20.3 to 1484 µg/100g and the amount of 5-MTHF ranged from 60 µg/100g to not determined. Whereas for the cooked beans, which were cooked according to the manufacturer's recommendations, the content of THF ranged from 15.3 to 1207 µg/100g and the amount of 5-MTHF ranged from 31.3 µg/100g to not determined. It was observed that the losses due the process were significant between the different varieties of beans, were the 5-MTHF compound was more susceptible to degradation. Furthermore, the losses were even greater when the beans were subjected to soaking before cooking, as in white beans. In cowpea were found the highest levels of folates, although it has been found only THF. There were significant differences among the three batches of each variety, which may be due to the different growing conditions and variation in the bean genotypes. The data show that the Brazilian beans are a good source of folate present in the diet / Mestrado / Ciência de Alimentos / Mestra em Ciência de Alimentos
1137

Estudo termodinâmico da região linear das isotermas de adsorção em sílica 'C IND. 18' para os componentes da síntese do piperonal a partir do óleo essencial da Piper hispidinervum C. DC / Thermodynamic study of the linear region of adsorption isotherms in 'C IND. 18' for compunds of piperonal synthesis from Piper hispidinervum C. DC essential oil

Moreira, Jean Vinícius, 1986- 23 August 2018 (has links)
Orientador: Marco Aurélio Cremasco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-23T11:02:30Z (GMT). No. of bitstreams: 1 Moreira_JeanVinicius_M.pdf: 3509735 bytes, checksum: 14df3cf30ed160fd0f79db993d4a1a65 (MD5) Previous issue date: 2013 / Resumo: O piperonal (ou heliotropina) apresenta aplicações industriais no ramo de cosméticos como fixador de fragrâncias, além de ser matéria prima para componentes de maior valor agregado, como a piperina que é empregada como antiiflamatorio; a vanila que tem aplicações antioxidantes; o pirebidil e a L-dopa que são agentes anti Parkinson. A síntese do piperonal, a partir do óleo essencial da pimenta longa (Piper hispidinervum C. DC), não gera um produto 100 % puro, dessa forma vê-se a importância de estudar uma maneira de separar o piperonal dos demais compostos, safrol, isosafrol e terpinoleno, também presentes no produto final da síntese. Dentre os métodos de purificação há a cromatografia líquida de alta eficiência, que ao longo do tempo mostrou-se eficaz na purificação e separação de diversos compostos. O método de separação baseada em cromatografia líquida de alta eficiência depende de diversos fatores, tais como a escolha da fase estacionária e da fase móvel, bem como estudos preliminares para a posterior implementação das variáveis definidas em uma escala semi preparativa ou preparativa. Na presente Dissertação a fase estacionária utilizada foi à sílica C18 e a fase móvel uma mistura binária 70/30 (v/v) de etanol e água. A escolha da fase móvel binária deveu-se aos bons resultados de resolução obtidos entre o componente de interesse, o piperonal, e o safrol, isosafrol e terpinoleno. A resolução alcançada para o piperonal com relação aos demais componentes, safrol e isosafrol foi de 2,986 e para o terpinoleno 6,900, a literatura relata que valores acima de 1,5 representam uma completa separação. A estimativa de parâmetros chave para a coluna, como a porosidade da partícula e a fração de vazios do leito, foram obtidas por meio do método dos momentos e as isotermas de adsorção por análise frontal. As isotermas foram determinadas entre 20 e 35 ºC, com passo de 5 ºC, apresentaram uma configuração linear. De posse das isotermas, foi possível estimar os valores das constantes modificadas de Henry e as grandezas termodinâmicas ?G, ?H e ?S para o sistema, por meio do gráfico de van't Hoff. Os valores de entalpia apontam que o piperonal é o composto menos retido, pois apresenta uma entalpia igual a -1,134 KJ mol-1, o maior valor se comparado com os obtidos para o safrol, isosafrol e terpinoleno, o que demonstra a baixa interação com a fase estacionária, e consequentemente um baixo tempo de retenção do composto na coluna. Esse efeito foi comprovado com os resultados obtidos para a entropia, o piperonal foi o composto que apresentou o maior valor (6,812 J mol K-1). Ao passo que o terpinoleno apresentou um valor igual a -6,485 J mol K-1. Estes valores descrevem que a retenção do piperonal é menor se comparada com a retenção do terpinoleno. Essas distinções proporcionaram a separação entre os compostos / Abstract: Piperonal (or heliotropine) presents industrial applications in the field of cosmetics as fragrance fixative, besides being the raw material for value-added components such as piperine which is employed as anti-inflammatory, vanilla which has antioxidants applications, pirebidil and L -dopa which are anti Parkinson's disease. The synthesis of piperonal, from the Piper hispidinervum C. DC, does not generate 100% pure product, that way we can see the importance of studying a way to purify piperonal from the others compounds, safrole, isosafrole and terpinoleno, also presente in the final product of the synthesis. A method to be studied is high performance liquid chromatography, which has been proved as an effective in the purification and separation of various compounds. The separation method based on high performance liquid chromatography depends on several factors, such as the choice of stationary phase and mobile phase, as well as preliminary studies for further implementation of the defined variables in a semi-preparative or preparative scale. In the present study silica gel C18 was used as stationary phase and mobile phase was a binary mixture 70/30 (v / v) ethanol and water, respectively. The choice of the binary mobile phase was due to the good results of resolution between the component of interest, piperonal, and others; safrole, isosafrole and terpinolene. The resolution achieved for piperonal in relation to other components, safrole and isosafrole was 2.986 and 6.900 for terpinoleno. The literature reports that values above 1.5 represent a complete separation. The estimation of key parameters for the column, such as the porosity of the particle and the bed porosity were obtained by the moment method and adsorption isotherms by frontal analysis. The isotherms determined between 20 and 35 º C, with steps of 5 º C showed a linear configuration. With the isotherms in hands, it was possible to estimate the values of the Henry constants and the thermodynamics parameters for the system through the van't Hoff graphical. The enthalpy values point out that piperonal is the less retained compound, because it shows an enthalpy value equal to -1.134 KJ mol-1, the greater value if we compare to the safrol, isosafrol and terpinoleno values, this value demonstrate low interaction with the stationary phase and, consequently, a low retention time of the compound in the column. This effect was proved by the entropy values, piperonal showed the greater entropy (6.812 J mol K-1). The terpinoleno showed a value equal to -6.485 J mol K-1. These values describe that piperonal retention is smaller if we compare to terpinoleno retention. This difference makes possible the separation between the compounds / Mestrado / Engenharia de Processos / Mestre em Engenharia Química
1138

Desenvolvimento e validação de métodos para a determinação de aminoglicosídeos em medicamentos veterinários / Development and validation of methods for the determination of aminoglycoside veterinary drug

Martínez Mejia, Mônica Johanna, 1987- 24 August 2018 (has links)
Orientador: Susanne Rath / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-24T01:27:44Z (GMT). No. of bitstreams: 1 MartinezMejia_MonicaJohanna_M.pdf: 2464111 bytes, checksum: 3b5ed561f639527706f188b968b06c29 (MD5) Previous issue date: 2013 / Resumo: Medicamentos veterinários têm sido amplamente empregados na cadeia de produção animal a fim de assegurar a saúde do animal e aumentar a produtividade. O Ministério da Agricultura, Pecuária e Abastecimento do Brasil (MAPA) tem como uma de suas prioridades atuais a fiscalização de medicamentos veterinários comercializados a nível nacional e este trabalho teve como objetivo fortalecer esta ação junto ao Lanagro de Campinas, SP. O principal foco foi o desenvolvimento e validação de método para a determinação dos antimicrobianos aminoglicosídeos estreptomicina e diidroestreptomicina por cromatografia líquida de alta eficiência acoplada à detecção por amperometria pulsada (HPLC-PAD). O comportamento eletroquímico dos compostos foi previamente estudado por voltametria cíclica, usando o eletrodo de ouro como eletrodo de trabalho. As condições ótimas do detector amperométrico foram definidas mediante planejamento experimental. A separação dos antimicrobianos foi realizada em uma coluna de troca aniônica (Carbopac PA1) e uma fase móvel composta de 0.070 mol L de NaOH. Como padrão interno foi usado a glicose. Os potenciais ótimos do pulso amperométrico foram: Edet= 0,1 V (tdet= 400 ms), Eoxid= 0,85 V (toxi= 400 ms) e Eativ= -0,65 V (tativ= 400 ms). O método foi validado conforme Guia de Validação publicado pelo MAPA em 2011 e aplicado na análise de amostras contendo estreptomicina e diidroestreptomicina associados a outros compostos, em formulações de pó solúvel, suspensão injetável e unguento intramamário. / Abstract: Veterinary drugs have been widely used in animal production in order to ensure both animal health and increase productivity. One of the current priorities of the Ministry of Agriculture, Livestock and Food Supply of Brazil (MAPA) is the inspection of veterinary drugs on the national market with the focus to enhance the practices of the National Laboratory Lanagro Campinas, SP. The main objective was the development and validation of a method for the determination of the aminoglycoside antimicrobials streptomycin and dihydrostreptomycin using high performance liquid chromatography coupled with pulsed amperometric detection (HPLC-PAD). The electrochemical behavior of the compounds was previously studied by cyclic voltammetry, using a gold electrode as working electrode. The optima conditions of the amperometric detector were defined by an experimental design. The separation of the antimicrobials was performed on an anion exchange column (Carbopac PA1) and a mobile phase of 0.070 mol L NaOH. Glucose was used as internal standard. The optimal potential of the triple pulse waveform of the amperometric detector were: Edet = 0.1 V (tdet = 400 ms and tint = 200 ms), Eoxid = 0.85 V (toxid = 400 ms) and Eativ = -0.65 V (tativ = 400 ms). The method was validated according to the Guide of Validation published by MAPA in 2011 and applied to the analyses of samples containing streptomycin and dihydrostreptomycin associated with other compounds in soluble powder formulations, injectable suspensions and intramammary ointments. / Mestrado / Quimica Analitica / Mestra em Química
1139

Síntese e caracterização de padrão de poliestireno para cromatografia de permeação em gel através da polimerização via radical livre controlada mediada por radicais nitróxidos / Synthesis and characterization of polystyrene standard for gel permeation chromatography using nitroxide mediated radical polymerization (NMRP)

Malere, Caroline Paganucci dos Reis 08 August 2011 (has links)
Orientador: Liliane Maria Ferrareso Lona / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-19T01:46:35Z (GMT). No. of bitstreams: 1 Malere_CarolinePaganuccidosReis_M.pdf: 1568071 bytes, checksum: 720e59aec25863d529bde7e649b7ece7 (MD5) Previous issue date: 2011 / Resumo: A Cromatografia de Permeação em Gel ou "Gel Permeation Chromatography (GPC), também conhecida como Cromatografia de Exclusão por Tamanho ou "Size Exclusion Chromatography" (SEC) é uma das técnicas analíticas mais utilizadas para separação e caracterização de polímeros naturais e sintéticos, copolímeros e proteínas, fornecendo informações distribuição de massa molar (MWD), viscosidade intrínseca (IV) e polidispersividade (PDI). A importância de sua resposta na análise de determinado polímero se reflete em termos de sua processabilidade, uma vez que as propriedades mecânicas e químicas são drasticamente afetadas por sua massa molar média, tamanho da cadeia e distribuição. Na técnica de GPC os padrões utilizados são de primordial importância para obtenção de resultados confiáveis, pois são utilizados nas construções de curvas de calibrações necessárias para aquisição dos resultados quanti e qualitativos na técnica. Apesar da vasta utilização da técnica de GPC no Brasil, tanto em centros de pesquisa como em indústrias químicas e petroquímicas, os padrões disponíveis para comercialização são todos adquiridos no exterior, por meio de importação a altos custos. Visto a necessidade de mudança desse paradigma, este trabalho tem como objetivo desenvolver um produto nacional utilizando a polimerização via radical livre mediada por radicais nitróxidos (NMRP), também chamada "living free radical polymerization (LFRP)". O padrão escolhido para o estudo foi o poliestireno (PS), por ser ele um dos padrões mais utilizados na calibração de análise de GPC orgânico. Um dos desafios enfrentados neste trabalho foi a obtenção de polímeros com índices de polidispersividade (PDI) variando de 1 a 1,10, distribuição de massa molar (MWD) estreita e alto grau de pureza, utilizando pela primeira vez uma mistura de iniciadores no processo NMRP. A NMRP é uma técnica robusta e inovadora comparada com a polimerização iônica que é atualmente o processo empregado para obtenção de polímeros com valores de PDI muito baixos. O processo NMRP possui vantagens frente à polimerização iônica para produção de polímeros com estrutura controlada, pois nele não são necessários etapas de purificações complexas, sendo que as reações requerem menos condições estritas em relação a impurezas e temperaturas de trabalho. Este é um processo simples e barato, na qual as reações podem ser realizadas em ampolas de vidros / Abstract: Gel Permeation Chromatography, also known as Size Exclusion Chromatography, is the most employed technique to characterize macromolecules such as proteins, copolymers, natural and synthetic polymers. It provides information such as molecular weight distribution (MWD), intrinsic viscosity (IV) and polydispersity (PDI). The importance of its response reflects in terms of polymer processability once the mechanic and chemicals properties are drastically affected by the polymer average molecular weight, chain size and distribution. The standards in the GPC technique have a great importance to obtain reliable results because they are employed in calibration curves needed to acquire the quantitative and qualitative data. Despite the wide use of GPC in Brazil at research centers, chemical and petrochemical industries, all the standards available are obtained outside the country through high importation costs. To change this paradigm, this work aims to develop a national product using the pseudo-living radical polymerization or living free radical polymerization (LFRP), which is a robust and innovative technique in the polymerization science area. The standard chosen was the polystyrene, which is the most used polymer in calibration curves of organic GPC analysis. Our challenge in this work was to obtain a controlled structure polymer with polydispersity index (PDI) between 1 and 1.10, narrow molecular weight distribution (MWD) and high purity degree, using to the best of our knowledge for the first time a mixture of initiators in a NMRP process. The NMRP is a robust and innovative technique compared with the ionic polymerization that is the currently employed process to obtain polymers with very low PDI. The advantages of NMRP process over ionic polymerization to produce controlled structure polymers are that no complicated purification steps are needed, controlled radical reactions require less stringent conditions for impurities and working temperatures, it is a simple and cheaper process, where the reactions can be carried out into glass ampoules / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
1140

Desenvolvimento de métodos alternativos para a determinação dos íons metálicos sódio, potássio, cálcio e magnésio em amostras de biodiesel / Development of alternative methods for the determination of sodium, potassium, calcium and magnesium ions in samples of biodiesel

Caland, Lilia Basilio de, 1982- 19 August 2018 (has links)
Orientador: Matthieu Tubino / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-19T12:43:39Z (GMT). No. of bitstreams: 1 Caland_LiliaBasiliode_D.pdf: 2271472 bytes, checksum: b5d42f422be0f6983fc7ae4d28db0182 (MD5) Previous issue date: 2011 / Resumo: O trabalho reportou dois métodos alternativos para determinação de íons metálicos (Na, K, Ca e Mg) em amostras de biodiesel. Tais métodos foram aplicados em amostras de biodiesel sintetisados a partir de diferentes óleos vegetais e, também, de gordura animal. Os métodos propostos utilizam, no tratamento da amostra, extração líquido-líquido em meio aquoso ácido, com aquecimento e extração assistida por ultrassom. A quantificação dos íons metálicos é feita por cromatografia de íons (Na, K, Ca e Mg) e por fotometria de chama (Na, K). Uma melhor separação cromatográfica dos íons Na, K, Ca e Mg foi obtida quando se empregou como eluente uma solução mista de ácido dipicolínico 1,7 mmol L com HNO3 2,5 mmol L. Para o método empregando cromatografia de íons, os limites de detecção (LD) e os limites de quantificação (LQ) foram respectivamente: 0,28 e 0,83 mg kg (Na); 0,38 e 1,13 mg kg (K); 0,41 e 1,22 mg kg (Ca); 0,29 e 0,86 mg kg (Mg). Os desvios padrão relativos dos valores encontrados foram menores do que 18,6 %. A exatidão do método foi avaliada através de teste de recuperação, com resultados entre 88,45 e 109,8 %, e por comparação dos dados obtidos por ICP OES. O teste t-Student e o teste¿F mostraram que ambos os métodos apresentaram resultados equivalentes em termos de exatidão e precisão. Na fotometria de chama, os valores de LD e LQ, foram respectivamente: 0,6 e 1,8 mg kg (Na); 0,4 e 1,4 mg kg (K). A recuperação obtida foi de 92,1 % para Na e de 103,6 % para K. Na comparação dos teores dos íons Na e K fornecidos pelo procedimento que usa fotometria de chama com aqueles provindos da cromatografia de íons, não foi observada diferença significativa entre os resultados, ao nível de confiança de 95%, tanto no que se refere à exatidão como à precisão. A simplicidade, exatidão, precisão e custo relativamente baixo dos métodos propostos sugerem que podem ser boas alternativas para a determinação dos íons metálicos (Na, K, Mg e Ca) em amostras de biodiesel / Abstract: In this work reports two alternative methods for the quantitation of metallic ions (Na, K, Mg e Ca) in biodiesel samples. The proposed methods were applied to biodiesel that were synthesized from different vegetable oils and also animal fat. The proposed method uses water extraction, heating and ultrasound. The quantitation of the ions was performed using ion chromatography (Na, K, Mg e Ca) and flame photometry (Na, K).The best chromatographic separation of the cations (Na, K, Ca e Mg) was observed when a solution containing dipicolinic acid (1.7 mmol L) plus nitric acid was used (2.5 mmol L). For the method with ion chromatography, the limits of detection (LOD) and of quantitation (LOQ) were respectively: 0.28 and 0.83 mg kg (Na); 0.38 and 1.13 mg kg (K); 0.41 and 1.22 mg kg (Ca); 0.29 and 0.86 mg kg (Mg). The relative standard deviations of the obtained values were smaller than 18.6 %. The accuracy was determined through recovery procedures, with presented results between 88.45 and 109.8 %, and also by comparison with the data obtained from ICP-OES. The Student.s t-test and the F-test showed that both methods presented equivalent results in with respect to accuracy and precision. In the case of flame photometry the LD and LQ values were respectively: 0.6 and 1.8 mg kg (Na); 0.4 and 1.4 mg kg (K). The observed recoveries were 92.1 % for Na and 103.6 % for K. In the comparison between the set containing the results obtained for Na and K with flame photometry with that came from ion chromatography, it was not observed significant difference at the 95% confidence level, both with respect to accuracy as well to precision. The simplicity, accuracy, precision and relative low cost of the proposed methods suggest that they are interesting alternatives for the quantitation of metallic ions (Na, K, Mg and Ca) in biodiesel samples / Doutorado / Quimica Analitica / Doutor em Ciências

Page generated in 0.0708 seconds