451 |
Efficient Energy Harvesting Interface for Implantable BiosensorsKatic, Janko January 2015 (has links)
Energy harvesting is identified as a promising alternative solution for powering implantable biosensors. It can completely replace the batteries, which are introducing many limitations, and it enables the development of self-powered implantable biosensors. An interface circuit is necessary to correct for differences in the voltage and power levels provided by an energy harvesting device from one side, and required by biosensor circuits from another. This thesis investigates the available energy harvesting sources within the human body, selects the most suitable one and proposes the power management unit (PMU), which serves as an interface between a harvester and biosensor circuits. The PMU targets the efficient power transfer from the selected source to the implantable biosensor circuits. Based on the investigation of potential energy harvesting sources, a thermoelectric energy harvester is selected. It can provide relatively high power density of 100 μW/cm2 at very low temperature difference available in the human body. Additionally, a thermoelectric energy harvester is miniature, biocompatible, and it has an unlimited lifetime. A power management system architecture for thermoelectric energy harvesters is proposed. The input converter, which is the critical block of the PMU, is implemented as a boost converter with an external inductor. A detailed analysis of all potential losses within the boost converter is conducted to estimate their influence on the conversion efficiency. The analysis showed that the inevitable conduction and switching losses can be reduced by the proper sizing of the converter’s switches and that the synchronization losses can be almost completely eliminated by an efficient control circuit. Additionally, usually neglected dead time losses are proved to have a significant impact in implantable applications, in which they can reduce the efficiency with more than 2%. An ultra low power control circuit for the boost converter is proposed. The control is utilizing zero-current switching (ZCS) and zero-voltage switching (ZVS) techniques to eliminate the synchronization losses and enhance the efficiency of the boost converter. The control circuit consumes an average power of only 620 nW. The boost converter driven by the proposed control achieves the peak efficiency higher than 80% and can operate with harvested power below 5 μW. For high voltage conversion ratios, the proposed boost converter/control combination demonstrates significant efficiency improvement compared to state-of-the-art solutions. / <p>QC 20150413</p>
|
452 |
Energy Harvesting from Exercise Machines: Forward Converters with a Central InverterLovgren, Nicholas Keith 01 June 2011 (has links) (PDF)
This thesis presents an active clamp forward converter for use in the Energy Harvesting From Exercise Machines project. Ideally, this converter will find use as the centerpiece in a process that links elliptical trainers to the California grid. This active clamp forward converter boasts a 14V-60V input voltage range and 150W power rating, which closely match the output voltage and power levels from the elliptical trainer. The isolated topology outputs 51V, higher than previous, non-isolated attempts, which allows the elliptical trainers to interact with a central grid-tied inverter instead of many small ones. The final converter operated at greater than 86% efficiency over most of the elliptical trainer’s input range, and produced very little noise, making it a solid choice for this implementation.
|
453 |
Nonlinear Analysis and Control of Standalone, Parallel DC-DC, and Parallel Multi-Phase PWM ConvertersMazumder, Sudip K. 17 August 2001 (has links)
Applications of distributed-power systems are on the rise. They are already used in telecommunication power supplies, aircraft and shipboard power-distribution systems, motor drives, plasma applications, and they are being considered for numerous other applications. The successful operation of these multi-converter systems relies heavily on a stable design. Conventional analyses of power converters are based on averaged models, which ignore the fast-scale instability and analyze the stability on a reduced-order manifold. As such, validity of the averaged models varies with the switching frequency even for the same topological structure.
The prevalent procedure for analyzing the stability of switching converters is based on linearized smooth averaged (small-signal) models. Yet there are systems (in active use) that yield a non-smooth averaged model. Even for systems for which smooth averaged models are realizable, small-signal analyses of the nominal solution/orbit do not provide anything about three important characteristics: region of attraction of the nominal solution, dependence of the converter dynamics on the initial conditions of the states, and the post-instability dynamics. As such, converters designed based on small-signal analyses may be conservative. In addition, linear controllers based on such analysis may not be robust and optimal. Clearly, there is a need to analyze the stability of power converters from a different perspective and design nonlinear controllers for such hybrid systems.
In this Dissertation, using bifurcation analysis and Lyapunov's method, we analyze the stability and dynamics of some of the building blocks of distributed-power systems, namely standalone, integrated, and parallel converters. Using analytical and experimental results, we show some of the differences between the conventional and new approaches for stability analyses of switching converters and demonstrate the shortcomings of some of the existing results. Furthermore, using nonlinear analyses we attempt to answer three fundamental questions: when does an instability occur, what is the mechanism of the instability, and what happens after the instability?
Subsequently, we develop nonlinear controllers to stabilize parallel dc-dc and parallel multi-phase converters. The proposed controllers for parallel dc-dc converters combine the concepts of multiple-sliding-surface and integral-variable-structure control. They are easy to design, robust, and have good transient and steady-state performances. Furthermore, they achieve a constant switching frequency within the boundary layer and hence can be operated in interleaving or synchronicity modes. The controllers developed for parallel multi-phase converters retain many of the above features. In addition, they do not require any communication between the modules; as such, they have high redundancy. One of these control schemes combines space-vector modulation and variable-structure control. It achieves constant switching frequency within the boundary layer and a good compromise between the transient and steady-state performances. / Ph. D.
|
454 |
Phase Shift Modulation Techniques for Bidirectional Onboard Chargers in Electric VehiclesYuan, Jiaqi January 2023 (has links)
Bidirectional onboard chargers (OBCs) are becoming mainstream commercial charging equipment for electric vehicles (EVs) because of their compactness, flexibility, and demand-response capabilities for power backup. This thesis focuses on the novel phase shift (PS) modulation techniques for efficiency improvement for bidirectional OBCs, including two-stage onboard chargers (TSOBCs) and single-stage onboard chargers (SSOBCs).
A comprehensive overview and investigation of the state-of-the-art solutions of bidirectional OBCs are presented. It reviews the current industrial status, industrial applications, and future trends and challenges. A detailed overview of the promising topologies for bidirectional OBCs, including two-stage and single-stage structures, is also discussed in this thesis.
Traditional PS modulation has been widely used in the back-end DC/DC converters of the TSOBCs because of its simple implementation. However, it is challenging to keep high efficiency at boundary operating points within wide specifications. Therefore, to improve efficiency at the boundary point for TSOBCs, the hybrid multiple phase shift (HMPS) modulation technique with minimal peak current optimization is presented to maximize the zero-voltage switching (ZVS) range. Compared to traditional single phase shift (SPS) modulation, the experimental results verify that the presented HMPS modulation strategy provides 1%-2% higher efficiency at the boundary points.
On the other hand, an improved compact SSOBC topology and novel PS modulation techniques are proposed. Since the traditional PS modulation is challenging for AC/DC converters to keep a unity power factor (PF), novel PS modulation techniques are presented for the proposed SSOBC. Firstly, a sinusoidal single phase shift (SSPS) modulation introduces a sinusoidal phase shift to maintain a high PF and high efficiency within a wide operating point. However, due to the high current at the zero-crossing point of the grid voltage of the SSPS modulation, the novel adaptive sinusoidal single phase shift (ASSPS) modulation is presented to address this issue, which reduces conduction loss and increases efficiency. Secondly, based on the ASSPS modulation, the adaptive sinusoidal extended phase shift (ASEPS) modulation with minimal peak current optimization is presented to introduce one more degree of freedom to extend the ZVS flexibility, which reduces switching loss. Moreover, the minimal peak current optimization reduces transformer current, further decreasing conduction losses. Therefore, the power loss is minimized.
Finally, this thesis presents the general design guideline of a 6 kW Silicon Carbide (SiC)-based bidirectional SSOBC, contributing to the further development of bidirectional SSOBC application. Experimental results verify the operating principle and high PF of the proposed SSPS, ASSPS, and ASEPS modulation. 1 kW experimental testing has validated that the peak efficiency is 95.3% with ASSPS modulation and 95.9% with ASEPS modulation. Compared to the existing pulse width modulation (PWM), the ASSPS modulation increased efficiency by 1.1%, and ASEPS modulation further increased by 1.7%. / Thesis / Doctor of Philosophy (PhD)
|
455 |
Average Current-Mode ControlChadha, Ankit January 2015 (has links)
No description available.
|
456 |
Green Electronics: High Efficiency On-chip Power Management Solutions for Portable and Battery-Powered ApplicationsHu, Anqiao 17 December 2010 (has links)
No description available.
|
457 |
Evaluation of Silicon Carbide Power MOSFET Short-Circuit Ruggedness, and MMC-Based High Voltage-Step-Down Ratio Dc/Dc ConversionXing, Diang 02 September 2022 (has links)
No description available.
|
458 |
Novel DC/DC Converters For High-Power Distributed Power SystemsFrancisco Venustiano, Canales Abarca 27 August 2003 (has links)
One of the requirements for the next generation of power supplies for distributed power systems (DPSs) is to achieve high power density with high efficiency.
In the traditional front-end converter based on the two-stage approach for high-power three-phase DPSs, the DC-link voltage coming from the power factor correction (PFC) stage penalizes the second-stage DC/DC converter. This DC/DC converter not only has to meet the characteristics demanded by the load, but also must process energy with high efficiency, high reliability, high power density and low cost. To meet these requirements, approaches such as the series connection of converters and converters that reduce the voltage stress across the main devices have been proposed.
In order to improve the characteristics of these solutions, this dissertation proposes high-efficiency, high-density DC/DC converters for high-power high-voltage applications.
In the first part of the dissertation, a DC/DC converter based on a three-level structure and operated with pulse width modulation (PWM) phase-shift control is proposed. This new way to operate the three-level DC/DC converter allows soft-switching operation for the main devices. Zero-voltage switching (ZVS) and zero-voltage and zero-current switching (ZVZCS) soft-switching techniques are studied, analyzed and compared in order to improve the characteristics of the proposed converter. This results in a series of ZVS and ZVZCS three-level DC/DC converters for high-power high-voltage applications. In all cases, results from 6kW prototypes operating at 100 kHz are presented.
In addition, with the ultimate goal of improving the power density of the DC/DC converter, a study of several resonant DC/DC converters that can operate at higher switching frequencies is presented. From this study, a three-element ZVS three-level resonant converter for applications with wide input voltage and load variations is proposed. Experimental results at 745 kHz obtained without penalizing the efficiency of the PWM approaches are presented.
The second part of the dissertation proposes a quasi-integrated AC/DC three-phase converter that aims to reduce the complexity and cost of the traditional two-stage front-end converter. This converter improves the complexity/low-efficiency tradeoff characteristics evident in the two-stage approach and previous integrated converters. The principle of operation for the converter is analyzed and verified on a 3kW experimental prototype. / Ph. D.
|
459 |
Bidirectional DC-DC Power Converter Design Optimization, Modeling and ControlZhang, Junhong 26 February 2008 (has links)
In order to increase the power density, the discontinuous conducting mode (DCM) and small inductance is adopted for high power bidirectional dc-dc converter. The DCM related current ripple is minimized with multiphase interleaved operation. The turn-off loss caused by the DCM induced high peak current is reduced by snubber capacitor. The energy stored in the capacitor needs to be discharged before device is turned on. A complementary gating signal control scheme is employed to turn on the non-active switch helping discharge the capacitor and diverting the current into the anti-paralleled diode of the active switch. This realizes the zero voltage resonant transition (ZVRT) of main switches. This scheme also eliminates the parasitic ringing in inductor current.
This work proposes an inductance and snubber capacitor optimization methodology. The inductor volume index and the inductor valley current are suggested as the optimization method for small volume and the realization of ZVRT. The proposed capacitance optimization method is based on a series of experiments for minimum overall switching loss. According to the suggested design optimization, a high power density hardware prototype is constructed and tested. The experimental results are provided, and the proposed design approach is verified.
In this dissertation, a general-purposed power stage model is proposed based on complementary gating signal control scheme and derived with space-state averaging method. The model features a third-order system, from which a second-order model with resistive load on one side can be derived and a first-order model with a voltage source on both sides can be derived. This model sets up a basis for the unified controller design and optimization. The Δ-type model of coupled inductor is introduced and simplified to provide a more clearly physical meaning for design and dynamic analysis. These models have been validated by the Simplis ac analysis simulation.
For power flow control, a unified controller concept is proposed based on the derived general-purposed power stage model. The proposed unified controller enables smooth bidirectional current flow. Controller is implemented with digital signal processing (DSP) for experimental verification. The inductor current is selected as feedback signal in resistive load, and the output current is selected as feedback signal in battery load.
Load step and power flow step control tests are conducted for resistive load and battery load separately. The results indicate that the selected sensing signal can produce an accurate and fast enough feedback signal. Experimental results show that the transition between charging and discharging is very smooth, and there is no overshoot or undershoot transient. It presents a seamless transition for bidirectional current flow. The smooth transition should be attributed to the use of the complementary gating signal control scheme and the proposed unified controller. System simulations are made, and the results are provided. The test results have a good agreement with system simulation results, and the unified controller performs as expected. / Ph. D.
|
460 |
Investigation of High-density Integrated Solution for AC/DC Conversion of a Distributed Power SystemLu, Bing 28 August 2006 (has links)
With the development of information technology, power management for telecom and computer applications become a large market for power supply industries. To meet the performance and reliability requirement, distributed power system (DPS) is widely adopted for telecom and computer systems, because of its modularity, maintainability and high reliability.
Due to limited space and increasing power consumption, power supplies for telecom and server systems are required to deliver more power with smaller volume. As the key component of DPS system, front-end AC/DC converter is under the pressure of continuously increasing power density. For conventional industry practices, some limitations prevents front-end converter meeting the power density requirement. In this dissertation, different techniques have been investigated to improve power density of front-end AC/DC converters.
For PFC stage, at low switching frequency, PFC inductor size is large and limits the power density. Although increasing switching frequency can dramatically reduce PFC inductor size, EMI filter size might be larger at higher switching frequency because of the change of noise spectrum. Since the relationship between EMI filter size and PFC switching frequency is unclear for industry, PFC circuits always operate with switching frequency lower than 150 kHz. Based on the EMI filter design method, together with a simple EMI noise prediction model, relationship between EMI filter corner frequency and PFC switching frequency was revealed. The analysis shows that switching frequency of PFC circuit should be higher than 400 kHz, so that both PFC inductor and EMI filter size can be reduced.
Although theoretical analysis and experimental results verify the benefits of high switching frequency PFC, it is essential to find a suitable topology that allows high switching frequency operation while maintains high efficiency. Three PFC topologies, single switch PFC, three-level PFC with range switch and dual Boost PFC, were evaluated with analysis and experiments. By using advanced semiconductor devices, together with proposed control methods, these topologies could achieve high efficiency at high switching frequency. Thus, the benefits of high frequency PFC can be realized.
In front-end converter, large holdup time capacitor size is another barrier for power density improvement. To meet the holdup time requirement, bulky holdup time capacitor is normally used to provide energy during holdup time. Holdup time capacitor requirement can be reduced by using wider input voltage range DC/DC converte. Because LLC resonant converter can realized with input voltage range without sacrificing its normal operation efficiency, it becomes an attractive solution for DC/DC stage of front-end converters. Moreover, its small switching loss allows it operating at MHz switching frequency and achieves smaller passive component size. However, lack of design methodology makes the topology difficult to be implemented. An optimal design methodology for LLC resonant converter has been developed based on the analysis on the circuit during normal operation condition and holdup time. The design method is verified by a 1 MHz switching frequency LLC resonant converter with 76W/in3 power density.
When front-end converter operates at high switching frequency, negative effects of circuit parasitics become more pronounced. By integrating active devices together with their gate drivers, Active Integrated power electronics module (IPEM) can largely reduce circuit parasitics. Therefore, switching loss and voltage stress on switching devices can be reduced. Moreover, IPEM concept can be extended into passive integration and EMI filter integration By using this power integration technology, power density and circuit performance of front-end converter can be improved, which is verified by theoretical analysis and experimental results. / Ph. D.
|
Page generated in 0.034 seconds