• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 238
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 4
  • 4
  • 1
  • 1
  • Tagged with
  • 239
  • 123
  • 114
  • 74
  • 58
  • 51
  • 45
  • 41
  • 41
  • 40
  • 38
  • 36
  • 36
  • 35
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Influência do núcleo de preenchimento na resistência à fratura de coroas de IPS-Empress 2 em pré-molares humanos

Fortkamp, Saulo January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T01:28:03Z (GMT). No. of bitstreams: 1 205752.pdf: 3690913 bytes, checksum: ed36ad33426221f38c4386e4b3f8b4a5 (MD5) / O objetivo deste estudo foi avaliar a influência de diferentes formas de núcleo de preenchimento na resistência à fratura de coroas de IPS-Empress 2 (EMP2). Quarenta pré-molares foram divididos aleatoriamente em 4 grupos. Os grupos foram restaurados da seguinte forma: Grupo 1, dentes com remoção total da coroa, restaurados com pinos fibro-resinosos (PFR) e núcleos de resina composta (NRC), apresentando preparos para coroas totais (PCT) de EMP2; Grupo 2, dentes com remoção parcial da coroa, restaurados com PFR e NRC, apresentando PCT de EMP2; Grupo 3; dentes com remoção parcial, restaurados com PFR e NRC, apresentando PCT de EMP2; e Grupo 4, dentes apenas com PCT de EMP2. Os espécimes foram submetidos à carga compressiva e não foi constatada nenhuma diferença estatisticamente significativa entre os grupos.
202

Efeitos da estimulação ultra-sônica sobre o processo de reparo em ferida de extração dental: estudo histológico em ratos

Santos Júnior, Paulo Villela [UNESP] 29 November 1984 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 1984-11-29Bitstream added on 2015-01-26T13:30:20Z : No. of bitstreams: 1 000024836.pdf: 1049991 bytes, checksum: 37bb33ffdfc89f960a1d9d69f8d97230 (MD5)
203

Procedimentos de seleção de cor, percepção visual de diferença de cor e fluorescência em odontologia estética

Rodrigues, Tatiana Pereira [UNESP] 02 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-02Bitstream added on 2014-06-13T18:20:15Z : No. of bitstreams: 1 rodrigues_tp_me_arafo.pdf: 1069391 bytes, checksum: 7966c77359cded07d74e880c53342fc2 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo deste estudo foi verificar os procedimentos realizados pelos cirurgiões-dentistas durante a seleção de cor dental, analisar a prática de utilização do método visual para a seleção da cor, avaliar a diferença de cor entre a escala Vitapan Classical e diversas resinas compostas e a fluorescência de diferentes cores de uma resina composta e da estrutura dental. Sessenta cirurgiões-dentistas foram selecionados para responder um questionário referente à seleção de cor dental. Observou-se que todos os profissionais utilizavam o método visual, apenas 2 utilizavam o método digital e 52% desconheciam o método digital. Para a análise da prática de utilização do método visual de seleção da cor com o auxílio da escala Vitapan Classical foi verificada a concordância nas classificações de cor entre o consenso de dois observadores e a dada pelo fabricante da resina composta Helio Fill (Vigodent), obtendo um nível de concordância sofrível (k = 0,3774). Por meio do sistema CIE L*a*b* foram calculadas as diferenças de cor entre a escala Vitapan Classical e cada uma das diversas resinas compostas avaliadas. Observou-se que oito resinas compostas não diferem visualmente da escala Vitapan Classical e duas apresentaram esta diferença. Para a análise da fluorescência foram coletadas 16 imagens para cada uma das 11 cores da resina composta Helio Fill (Vigodent) e estrutura dental sob iluminação UV. Estas processadas matematicamente, quantificando a intensidade de fluorescência. Verificou-se que a cor A1 apresentou maior média de intensidade de fluorescência e a tonalidade C3 apresentou a menor. Porém, a estrutura dental apresentou valor médio inferior a todas as cores avaliadas. / The purpose of this study was to evaluate the procedures carried out by dentists during dental shade selection, assess the practice of the visual method to select dental shade, to evaluate the shade difference between Vitapan Classical shade guide and several composite resins, to evaluate the fluorescence in different shades of a composite resin and dental structure. Sixty professionals were selected, who answered to questions of the form about to select dental shade. The totality of the professionals selected dental shade by visual method; only 2 used digital methods; 52% did not know about the digital method. To assess the practice of the use of visual method to select dental shade, it was observed the agreement in shade classification between two examiners and the classification established by the composite resin manufacturer Helio Fill (Vigodent) which resulted in a suffering level of agreement (k = 0.3774). Through CIE L*a*b* system the difference of the total shade between Vitapan Classical shade guide and the composite resin was calculated and it was observed that eight of the composite resins assessed do not differ visually from Vitapan Classical shade guide, and two showed a perceptive difference to human eye. For the fluorescence analysis sixteen images were captured by the camera for the different shades of Helio Fill (Vigodent) composite resin and dental structure under UV LED illumination, and they were processed mathematically, quantifying the fluorescence intensity. It was observed that A1 shade showed the higher mean of fluorescence intensity, whereas C3 shade showed the lower mean among the composite resin shades. However, the mean intensity of dental structure was lower than those related to all the shades evaluated. (Complete abstract, click electronic access below)
204

Pinos anatômicos cimentados com agentes resinosos em diferentes comprimentos radiculares: estudo da interface e da resistência de união / Anatomic Posts Luted With Resin Gents In Different Lengths Roots: Study Of Interface And Bond Strength

Souza, Niélli Caetano de January 2015 (has links)
Made available in DSpace on 2015-04-30T14:06:25Z (GMT). No. of bitstreams: 1 000467675-Texto+Completo-0.pdf: 1437644 bytes, checksum: dbcd8d581c9d8dc4da7301e5b4e3ac75 (MD5) Previous issue date: 2015 / The objectives of the study were to evaluate the influence of the depth of cement, the cement type and mechanical cycling through the pullout bond strength of direct anatomical post in fragile bovine roots and assess the thickness of resin cements in different root thirds of direct anatomical post and fiber post in human single-rooted. Eighty bovine roots were obtained for the bond strength by pullout. The canals were endodontically treated and extended with diamond burs. The roots were divided in two groups: G1 - direct anatomical posts cemented with RelyX ARC; G2 - direct anatomical posts cemented with RelyX U200. Both groups were divided in two subgroups, each subgroup (n = 10) cemented with a depth of 5 mm or 10 mm. Half of the specimens of each depth was submitted to mechanical cycling. The specimens were submitted to pullout test in a universal testing machine. The results were analyzed by ANOVA three factors (α=0. 05). To study the thickness of the resin cement, 40 single-rooted human upper anterior teeth were obtained. The teeth were endodontically treated and weakened with drill Largo and diamond burs in a depth of 10 mm. The teeth were randomly divided in four groups (n = 10): Group 1 - fiber post + RelyX ARC; Group 2 - fiber post + RelyX U200 +; Group 3 - anatomical post + RelyX ARC; Group 4 - anatomical post + RelyX U200. The dyes 0. 1% Fluorescein and 0. 1% Rhodamine B isothiocyanate were added to adhesive system and resin cement, respectively. After cementation, the roots were sectioned in slices and observed by confocal laser scanning microscopy. Datas were analyzed by ANOVA followed by Tukey test (α=0. 05). For the pullout test, the resin cement factor (p = 0. 0001) and mechanical loading factor (p = 0. 0001) were significant. The bond strength of RelyX U200 (6. 47 MPa) was statistically superior to RelyX ARC (5. 51 MPa). The depth of cementation factor was not significant (p=0. 328). However, the interaction between depth and mechanical cycling was significant (p=0. 0001). For a depth of 5 mm of cementation, the average bond strength of samples without mechanical cycling (6. 98 MPa) was statistically higher to samples with mechanical cycling (4. 78 MPa). For the depth of cementation of 10 mm, there was no statistical difference between the samples with and without mechanical cycling. For analysis of the resin cement thickness, post, cement and root thirds influenced the thickness of the resin cement (p <0. 001). The thickness of resin cement was significantly lower in anatomical post groups than in fiber post groups, except in the apical third of the canal. There was no significant statistical difference between the cements for the direct anatomical post; for the fiber posts, only the cervical third showed a statistically significant difference between the cements. It was concluded that the direct anatomical posts cemented in the 10 mm depth obtained the best results with RelyX U200, regardless of mechanical cycling. In addition, in weakened roots, the preparation of direct anatomical post allows the better adaptation of post to the channel walls, favoring the formation of a thin and uniform cement film. / Os objetivos do estudo foram avaliar a influência da profundidade de cimentação, do cimento resinoso e da ciclagem mecânica na resistência à tração por pull out de pinos anatômicos diretos em raízes bovinas fragilizadas, assim como avaliar a espessura de cimentos resinosos nos terços radiculares de pinos anatômicos diretos e pinos de fibra de vidro em raízes unirradiculares humanas. Para o ensaio de pull out, 80 remanescentes radiculares bovinos foram tratados endodonticamente e alargados com pontas diamantadas, sendo divididos em dois grupos: G1 - pinos anatômicos diretos cimentados com RelyX ARC; G2 - pinos anatômicos diretos cimentados com RelyX U200. Ambos os grupos foram divididos em dois subgrupos, sendo cada subgrupo (n=10) cimentado com profundidade de 5 mm e 10 mm. Metade dos corpos de prova de cada profundidade recebeu ciclagem mecânica. Os corpos de prova foram submetidos ao ensaio de pull out em máquina de ensaio universal. Os resultados foram analisados pela ANOVA de três fatores (α=0,05). Para o estudo da espessura do cimento resinoso, 40 raízes unirradiculares humanas da região ântero-superior foram tratadas endodonticamente e fragilizadas com broca Largo e pontas diamantadas na profundidade de 10 mm. Os dentes foram divididos aleatoriamente em quatro grupos (n=10): Grupo 1 - pino de fibra de vidro + RelyX ARC; Grupo 2 - pino de fibra de vidro + RelyX U200; Grupo 3 - pino anatômico + RelyX ARC; Grupo 4 - pino anatômico + RelyX U200. Os corantes Fluorosceína 0,1% e Isotiocianato de Rodamina B 0,1% foram adicionados ao sistema adesivo e ao cimento resinoso, respectivamente. Após cimentação, as raízes foram seccionadas em fatias e observadas em microscopia confocal de varredura à laser. Os dados foram analisados pela ANOVA, seguido do teste Tukey (α=0,05). Para o ensaio de pull out, os fatores cimento resinoso (p=0,0001) e ciclagem mecânica (p=0,0001) foram significativos. A resistência de união do RelyX U200 (6,47 MPa) foi estatisticamente superior ao RelyX ARC (5,51 MPa). O fator profundidade de cimentação não foi significativo (p=0,328). No entanto, a interação entre ciclagem mecânica e profundidade foi significativa (p=0,0001). Para a profundidade de 5 mm, a média de resistência de união sem ciclagem mecânica (6,98 MPa) foi estatisticamente superior a com ciclagem mecânica (4,78 MPa). Para a profundidade de 10 mm, não houve diferença estatística entre as amostras sem e com ciclagem mecânica. Para a análise da espessura de cimento resinoso, o pino, o cimento e os terços radiculares influenciaram na espessura do cimento (p<0,001). A espessura de cimento foi significativamente menor nos pinos anatômicos do que nos pinos de fibra de vidro, exceto no terço apical do canal. Não houve diferença estatística significativa entre os cimentos para pinos anatômicos; para os grupos com pinos de fibra de vidro, apenas o terço cervical apresentou diferença estatística significativa entre os cimentos. Concluiu-se que os pinos anatômicos diretos cimentados em profundidade de 10 mm obtiveram os melhores resultados quando utilizado o RelyX U200, independente da ciclagem mecânica, e que, em raízes fragilizadas, a confecção de pinos anatômicos diretos permite uma melhor adaptação dos pinos às paredes do canal, favorecendo a formação de uma película de cimento fina e uniforme.
205

Efeitos da estimulação ultra-sônica sobre o processo de reparo em ferida de extração dental : estudo histológico em ratos /

Santos Júnior, Paulo Villela. January 1984 (has links)
Orientador: Ronaldo Maia Melhado / Resumo : Não disponível / Abstract : Not available / Doutor
206

Avaliação das alterações orais em candidatos ao transplante de células-tronco hematopoéticas : identificação de fatores de risco para complicações clínicas /

Barrach, Regina Haddad. January 2010 (has links)
Orientador: Jair Cortez Montovani / Banca: Mariza Akemi Matsumoto / Banca: José Vicente Tagliarini / Resumo: A cavidade oral é um local potencial de complicações em pacientes imunossuprimidos podendo ser um importante local de agentes causadores de infecções sistêmicas, o que pode contribuir para a perda do transplante de célulastronco hematopoéticas, ou mesmo para o óbito do paciente. OBJETIVOS: Apresentar um modelo de avaliação para identificação de potenciais riscos das doenças orais em pacientes imunossuprimidos antes e após transplante de célulastronco hematopoéticas. O presente estudo é clínico, prospectivo, com modelo de coorte temporal longitudinal, realizado no período de julho de 2007 a dezembro de 2008 no Hospital Amaral Carvalho em Jaú/SP. Foram incluídos 65 pacientes divididos em 2 grupos de acordo com o tipo de transplante (alogênico e autológo), maiores de 18 anos, de ambos os sexos, portadores de doenças hematológicas malignas ou não, e que se submeteram ao transplante de células-tronco hematopoéticas no período acima citado. Foram feitas 3 avaliações odontológicas: no período pré-transplante (momento 1), uma semana após a infusão das célulastronco (momento 2) e cem dias pós-transplante (momento 3). Os dados de cada momento foram correlacionados de acordo com a pontuação obtida e os indivíduos foram classificados como grau de risco leve, moderado, grave e gravíssimo no momento 1 e graus de toxicidade leve, moderado, grave e gravíssimo nos momentos 2 e 3 para as complicações clínicas da cavidade oral. As alterações patológicas da boca mais frequentes foram as gengivites, pericoronarite de 3º molar e próteses nos três momentos. Porém, nos momentos 2 e 3 a principal causa do aumento da toxicidade associada a imunossupressão foi a mucosite. Mesmo em indivíduos classificados com grau leve, quando tinham mucosite em graus variados o período de internação hospitalar era maior o mesmo ocorrendo para as recidivas e óbitos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Oral cavity is a potential site for complications in immunosuppressed patients and it can be an important center of causative agents of systemic infections, which can contribute to the loss of hematopoietic stem cell transplantation, or even to patient's death. To present an assessment model for identifying the potential risks of oral diseases in immunosuppressed patients, before and after the hematopoietic stem cell transplantation. This is a clinical, prospective study with model of longitudinal temporal cohort performed from July/2007 to December/2008, at the Amaral Carvalho Hospital, Jau, São Paulo. The sample comprised 65 patients who were divided into 2 groups according to transplant type (allogenous and autologous), older than 18 years old, both sexes, with or without malignant hematopoietic diseases, and who undergone hematopoietic stem cell transplantation during the aforementioned period. Three dental assessments were executed: at pretransplantation (Time 1), at one week after stem cell infusion (Time 2), and at 100-day post-transplantation (Time 3). Data of each time were correlated according to the score obtained, and the individuals were classified in: mild, moderate, severe, and very severe risk groups at Time 1; and, in mild, moderate, severe and very severe toxicity levels at Time 2 and 3, regarding to clinical complications of oral cavity. The most frequent pathological conditions were: gingivitis, pericoronaritis due to third molar, and presence of prosthesis, at three times. However, at Time 2 and 3, the main cause of the increase of toxicity associated to immunosuppression was mucositis. Even when mild-risk individuals exhibited mucositis at several levels, the hospital stay length was higher, as well as the relapses and deaths. In the identification of oral diseases in patients who will undergo hematopoietic stem cell transplantation, mucositis accounted... (Complete abstract click electronic access below) / Mestre
207

Resistência de união à dentina de um sistema adesivo de frasco único: avaliação em 24 horas e seis meses de armazenamento

Manfroi, Fernanda Borguetti January 2014 (has links)
Made available in DSpace on 2014-07-04T02:02:33Z (GMT). No. of bitstreams: 1 000459061-Texto+Completo-0.pdf: 2282963 bytes, checksum: c9b1fec421065d44d34540a0b1217b0a (MD5) Previous issue date: 2014 / The aim of this study was to evaluate the bond strength of Scotchbond Universal to dentin in both total-etch and self-etch applications after storage in water for 24 h and 6 months. The occlusal surface of 24 third molars was removed to obtain flat dentin surfaces, and the teeth were divided into four groups (n=6/grupo): G1 – total-etch application of Scotchbond Universal; G2 – self-etch application of Scotchbond Universal; G3 – Scotchbond Multi Purpose (total-etch application control); G4 – Clearfil SE Bond (self-etch application control). Following the adhesive application, a 6 mm height block of composite resin Z250 was built on the adhesive area. After storage in distilled water at 37ºC for 24 hours, the tooth/resin sets were cut parallel to the long axis of the tooth, in the x and y directions, with a section of about 0. 8 mm2. Forty specimens were obtained for each group; 20 specimens were immediately submitted to microtensile bond strength test, and the others after storage in distilled water at 37o C for 6 months. The microtensile bond strength test was performed in an universal testing machine (EMIC-DL 2000) at 0. 5 mm/min crosshead speed. The failures were observed in scanning electron microscopy (SEM). Additionally, two sets of each group were sectioned mesio-distal in the center of their crown with a diamond blade. The surfaces were polished by wet sanding with 400, 600 and 1200-grit silicon carbide abrasive paper, followed by polishing with 6, 3, 1 and ¼ m diamond paste.The samples were demineralized, deproteinized, dried, metalized and observed on a scanning electron microscope at 1. 500x. The bond strength means (MPa) obtained were the following: 24 h – G1 (39. 37); G2 (31. 02); G3 (35. 09); G4 (35. 84); 6 months – G1 (36. 99); G2 (40. 58); G3 (32. 44); G4 (41. 75). According to two-way ANOVA, there was no significance for adhesive system (p=0,110) and storage time (0,108), but the interaction of adhesive system and storage time was significant (p=0. 015). At 24 h, there was no statistical difference in bond strength between the adhesive systems (p>0,05). At 6 months, there was statistical difference between the adhesive systems (p<0. 05). Clearfil SE Bond obtained the higher bond strength mean, not differing statistically from self-etch application of Scotchbond Universal. Total-etch application of Scotchbond Universal did not differ statistically from Scotchbond Multi Purpose. Most of failures were mixed in both periods of evaluation.The SEM images of the adhesive interface of Scotchbond Universal total-etch application and Scotchbond Multi Purpose showed thicker hybrid layers and more resin tags in comparison with Scotchbond Universal self-etch application and Clearfil SE Bond. It was concluded that the simplification of Scotchbond Universal in one bottle did not decrease the bond strength of this adhesive to dentin during 6 months of storage. / O objetivo do estudo foi avaliar a resistência de união à dentina do sistema adesivo Scotchbond Universal na versão total-etch e self-etch em 24 horas e 6 meses de armazenamento. A superfície oclusal de 24 dentes terceiros molares hígidos foi removida para obter superfície plana em dentina, sendo divididos aleatoriamente em quatro grupos (n=6/grupo): G1 - Scotchbond Universal na versão total-etch; G2 – Scotchbond Universal na versão self-etch; G3 – Scotchbond Multi Purpose (controle da versão total-etch); G4 – Clearfil SE Bond (controle da versão self-etch). Sobre o sistema adesivo foi confeccionado um bloco de 6 mm de altura em resina composta Z250. Após 24 horas de armazenagem em água destilada a 37º C, os conjuntos dente/resina foram cortados paralelamente no longo eixo do dente, nos sentidos x e y, com secção de aproximadamente 0,8 mm2. Quarenta corpos de prova foram obtidos para cada grupo, sendo 20 submetidos imediatamente ao teste de resistência à microtração e, os outros 20, após 6 meses de armazenamento em água destilada a 37º C. O ensaio de microtração foi realizado em uma máquina de ensaio universal EMIC DL-2000, com uma velocidade de 0,5 mm/min. Os tipos de falha foram observados em microscopia eletrônica de varredura (MEV).Adicionalmente, dois conjuntos dente/resina foram preparados e seccionados no sentido mésio-distal, no centro de suas coroas, com um disco diamantado de dupla face. As superfícies foram polidas com lixas de carbeto de silício 400, 600 e 1200, seguido de polimento com pastas diamantadas de granulação 6, 3, 1 e ¼ m. As amostras foram desmineralizadas, desproteinizadas, secadas, metalizadas e observadas em MEV em aumento de 1. 500 vezes. No teste de microtração as médias obtidas (MPa) foram as seguintes: 24 h – G1 (39,37); G2 (31,02); G3 (35,09); G4 (35,84); 6 meses – G1 (36,99); G2 (40,58); G3 (32,44); G4 (41,75). De acordo com o teste ANOVA de duas vias não houve significância para o sistema adesivo (p=0,110) e para o tempo (0,108), mas apenas para a interação entre sistema adesivo e tempo (p=0,015). No período de 24 horas, não houve diferença estatística significativa na resistência à microtração entre os sistemas adesivos (p>0,05). Na avaliação de seis meses de armazenamento, houve diferença estatística entre os sistemas adesivos (p<0,05). O Clearfil SE Bond apresentou o maior valor médio de resistência à microtração, não diferindo estatisticamente do Scotchbond Universal self-etch e total-etch. O Scotchbond Universal total-etch não diferiu estatisticamente do Scotchbond Multi Purpose.Os tipos de falha foram predominantemente mistas para os dois períodos de avaliação. A interface adesiva do Scotchbond Universal na versão total-etch e o Scotchbond Multi Purpose apresentaram camada híbrida mais espessa e mais tags de resina em comparação ao Scotchbond Universal na versão self-etch e Clearfil SE Bond. Concluiu-se que a simplificação em frasco único do Scotchbond Universal não causou diminuição nos valores de resistência de união deste material à dentina em até 6 meses de avaliação.
208

Influência do preparo cavitário e do material restaurador na carga e no tipo de fratura de premolares tratados endodonticamente

Silva, Ana Amélia Bianchi e January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2 000406883-0.pdf: 1791767 bytes, checksum: 2bb90cc0781205c8981e1781f9ba9327 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study evaluated the influence of different restoration techniques on the load and type of fracture in endodontically treated pre-molars. Sixty maxillary premolars were divided into the following groups: G1 – healthy; G2 – MOD cavity and direct restoration with Four Season inlay; G3 –MOD cavity and indirect restoration with Adoro inlay; G5 – MOD cavity and restoration with Empress inlay; G4 and G6 – similar to groups 3 and 5, respectively, but with covering the cuspids (onlay). Endodontic treatment was performed in Groups 2 to 6. The specimens were submitted to the compression test in a universal testing machine at a crosshead speed of 0. 5 mm/minute. The type of fracture was classified as follows: Fracture Type I – restricted to the restoration; Fracture Type II – restoration and dental cuspid above the amelocemental junction; Fracture Type III – restoration and dental cuspid below the amelocemental junction; Fracture Type IV – restoration and cuspid below the amelocemental junction with exposure of the pulp chamber; Fracture Type V – along the root. The means of the fracture load values were submitted to Analysis of Variance and the Tukey test, and the results of the fracture type were submitted to the Kruskal-Wallis test at a level of significance of 5%. There was statistically significant difference in the fracture load among the groups (p=0,01). The highest fracture load value was obtained in the group of healthy teeth (1370. 61 N), not differing statistically from the onlay group in Empress (1304. 21 N), both values being statistically higher than those of the other groups. Intermediate values were obtained for the groups inlay in Empress (918. 76 N), onlay in Adoro (861. 15 N) and inlay in Adoro (792. 71 N), which did not differ statistically among them.The lowest fracture load value was obtained for the group with direct restoration with Four Season (666. 08 N) group, which did not differ statistically from the inlay group in Adoro. As regards the type of fracture, there was statistically significant difference among the groups (p=0. 001). The groups onlay in Adoro and healthy teeth did not differ statistically between them, presenting the highest percentage of fractures with the best prognosis (without pulp chamber exposure), and no tooth fractured along the root. Whereas the other experimental groups also did not differ statistically among them, but all presented fractures extending along the root (the worst prognosis). / Este trabalho avaliou a influência de diferentes técnicas restauradoras na carga e no tipo de fratura em premolares tratados endodonticamente. Sessenta premolares superiores foram divididos nos seguintes grupos: G1 – hígidos; G2 – cavidade MOD e restauração direta com Four Season tipo inlay; G3 – cavidade MOD e restauração indireta com Adoro tipo inlay; G5 – cavidade MOD e restauração com Empress tipo inlay; G4 e G6 – semelhantes aos grupos 3 e 5, respectivamente, mas com cobertura de cúspides (tipo onlay). Foi realizada endodontia nos grupos 2 a 6. Os corpos-de-prova foram submetidos ao ensaio de compressão em máquina de ensaio universal com velocidade de 0,5 mm/minuto. O tipo de fratura foi classificado da seguinte forma: fratura tipo I – restrita à restauração; fratura tipo II – restauração e cúspide dentária acima da junção amelocementária; fratura tipo III – restauração e cúspide dentária abaixo da junção amelocementária; fratura tipo IV – restauração e cúspide abaixo da junção amelocementária com exposição da câmara pulpar; fratura tipo V – ao longo da raiz. As médias dos valores de carga de fratura foram submetidos à Análise de Variância e Teste de Tukey, e os resultados do tipo de fratura foram submetidos ao teste Kruskal-Wallis ao nível de significância foi de 5%.Houve diferença estatisticamente significante na carga de fratura entre os grupos (p=0,01). O maior valor de carga de fratura foi obtido no grupo dos dentes hígidos (1370,61 N), não diferindo estatisticamente do grupo onlay em Empress (1304,21 N), sendo ambos os valores estatisticamente superiores aos demais grupos. Valores intermediários foram obtidos para os grupos inlay em Empress (918,76 N), onlay em Adoro (861,15 N) e inlay em Adoro (792,71 N), os quais não diferiram estatisticamente entre si. O menor valor de carga de fratura foi obtido para o grupo da restauração direta com Four Season (666,08 N), não diferindo estatisticamente do grupo inlay em Adoro. Também houve diferença estatística significativa para o tipo de fratura entre os grupos (p=0,001). Os grupos onlay em Adoro e hígidos não diferiram estatisticamente entre si, apresentando maior porcentagem de fraturas com melhor prognóstico (sem exposição da câmara pulpar), e nenhum dente com fratura ao longo da raiz. Já os demais grupos experimentais também não diferiram estatisticamente entre si, mas todos apresentaram fraturas se estendendo ao longo da raiz (pior prognóstico).
209

Influência de cimentos resinosos autoadesivos na deflexão de cúspides e carga de fratura de pré-molares restaurados com inlays em resina composta

Salaverry, Aurélio January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2 000431091-0.pdf: 6484611 bytes, checksum: ee0b40e71498d6a5f8496211522ca10f (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the influence of four resin cements (one conventional and three self-adhesive) on cuspal deflection, fracture load and failure mode of endodontically treated teeth restored with composite resin inlays. Seventy-two maxillary premolars were randomly divided into four groups: G1 - sound teeth (control); G2 - cavities without restoration; G3 - RelyX ARC; G4 - RelyX U100; G5 - Maxcem Elite; G6 - SeT. The teeth from groups 2, 3, 4, 5 and 6 received mesio-occlusal-distal preparations and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4, 5 and 6. Inlays with Z350 XT composite resin were built over each cast and luted with the resin cements. After storage in water at 37o C for 72 hours, a 200-N load was applied on the occlusal face using an 8 mm diameter metal sphere, and the cuspal deflection was measured using a micrometer. Following, the specimens were submitted to 500,000 cycles of mechanical fatigue, and the cuspal deflection was measured again. The specimens were then submitted to an axial load until failure. According to Kruskal-Wallis, group 2 (69 μm) had the highest cuspal deflection before mechanical fatigue, and did not differ statistically from group 6 (51 μm). Group 1 (4 μm), group 3 (4 μm) and group 4 (5 μm) obtained the lowest cuspal deflections, and did not differ between them. Intermediate value was obtained for group 5 (21 μm), and this group did not differ statistically from groups 3, 4 and 6. According to Wilcoxon test, there was no statistically difference between the cuspal deflection before and after mechanical fatigue only for group 3 (p=0,015). According to Kruskal- Wallis, group 1 (1902 N) had the highest fracture load, and differed statistically from the other groups. The second highest value was obtained for group 3 (980,8 N), and differed statistically from the other groups. Group 4 (670,6 N), group 5 (533,5 N), group 6 (601,3 N) and group 2 (526,6 N) did not differ between them. There was a predominance of recovery fractures for the restored groups. Composite resin inlays luted with RelyX ARC kept the cuspal deflection stability, obtained higher strength of the teeth, as well as fractures with good prognosis for rehabilitation. / O objetivo desse estudo foi avaliar a influência de quatro cimentos resinosos (um convencional e três autoadesivos) na deflexão de cúspides, carga de fratura e tipos de fratura de pré-molares com acesso endodôntico e restaurados com inlays em resina composta. Setenta e dois primeiros pré-molares foram divididos aleatoriamente em seis grupos (n=12): G1 (controle) - hígidos; G2 – cavidades sem restauração; G3 –RelyX ARC; G4 –RelyX U100; G5- Maxcem Elite; G6 –SeT. Os Grupos 2-6 receberam preparos cavitários MOD e acesso endodôntico. Os grupos 3-6 foram moldados com silicona por adição e vazados com gesso especial para confecção de inlays em resina composta Z350 XT. As restaurações indiretas foram cimentadas nas respectivas cavidades com carga de 1 Kg e fotoativadas. Após armazenagem em água destilada a 37º C por 72 horas, carga de 200 N foi aplicada na região oclusal com uma esfera de 8 mm de diâmetro acoplada na máquina de ensaio universal EMIC DL 2000, sendo medida a deflexão de cúspides com um micrômetro digital. Os corpos de prova foram então submetidos a 500. 000 ciclos de fadiga mecânica, e novo teste de deflexão de cúspides foi realizado. Em seguida, os corpos de prova foram submetidos ao ensaio de compressão até a fratura na máquina de ensaio universal. De acordo com o teste de Kruskal-Wallis, a maior deflexão de cúspides pré-fadiga foi obtida para o grupo 2 (69 μm), não diferindo estatisticamente do grupo 6 (51 μm). As menores deflexões de cúspides foram obtidas para o grupo 1 (4 μm), o grupo 3 (4 μm) e o grupo 4 (5 μm), os quais não diferiram estatisticamente entre si. Valor intermediário foi obtido para o grupo 5 (21 μm), não diferindo estatisticamente dos grupos 3, 4 e 6. De acordo com o teste de Wilcoxon, não houve diferença estatística entre a deflexão de cúspides pré e pós-fadiga apenas para o grupo 3 (p=0,015). De acordo com Kruskal-Wallis, a maior carga de fratura foi obtida para o grupo 1 (1902 N), diferindo estatisticamente dos outros grupos. Segundo maior valor foi obtido para o grupo 3 (980,8 N), diferindo estatisticamente dos outros grupos. Grupo 4 (670,6 N), grupo 5 (533,5 N), grupo 6 (601,3 N) e grupo 2 (526,6 N) não diferiram estatisticamente entre si. Para os grupos restaurados, houve predominância de fraturas recuperáveis. Inlays em resina composta cimentadas com RelyX ARC mantiveram a estabilidade da deflexão de cúspides, proporcionaram maior recuperação da resistência da estrutura dentária, assim como fraturas mais favoráveis para a reabilitação.
210

Avaliação clínica retrospectiva de restaurações estéticas : classe III, IV e V / Retrospective clinical evaluation of esthetic restorations : class III, IV and V

Vieira, Rodrigo Monteiro January 2015 (has links)
O objetivo do presente estudo foi realizar uma avaliação clínica retrospectiva de restaurações diretas de resina composta de classe III, IV e V em dentes anteriores e pré-molares utilizando os métodos USPHS e FDI. Oitenta e sete pacientes foram selecionados através de uma pesquisa dos prontuários presentes no Setor de Acolhimento da Faculdade com restaurações realizadas entre 2000 a 2013 que possuíam um período mínimo em boca de 6 meses. Foram incluídos pacientes adultos de ambos os sexos que receberam tratamento com restaurações de classe III, IV ou V realizadas com as resinas compostas: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic e Opallis; realizadas com sistema adesivo convencional; em dentes vitais ou não vitais. Aqueles pacientes que possuíam higiene oral precária ou com necessidades especiais não foram incluídos no estudo. A avaliação clínica foi feita através dos métodos USPHS e FDI modificados por um examinador calibrado. A análise de sobrevivência das restaurações foi realizada através do método Kaplan-Meier e teste Log-Rank para comparação entre os grupos. A regressão de Cox multivariada e Hazard Ratio foram empregadas para verificar os fatores associados à falha das restaurações. O nível de significância foi de 5%. Foram avaliadas 272 restaurações, com um intervalo de tempo em boca de 8 meses até 13 anos (média - 4,8 anos). Foram avaliadas 120 restaurações classe III, entre elas, 15 apresentaram falhas (12,5%), com uma taxa de falha anual de 2,74%. Já para as restaurações de classe IV, realizou-se a avaliação de 80 restaurações, 38 demonstraram falhas (47,5%), como uma taxa de falha anual de 12,6%. E para as de classe V, foram analisadas 72 restaurações, sendo observada a presença de falhas em 27 delas (37,5%), com uma taxa de falha anual de 9,3%. O motivo mais comum de falha foi por fratura e/ou retenção para as três classes, ocorrendo em 73 casos. Dentes não vitais demonstraram 50% de falha em um tempo médio de 4,8 anos com uma taxa de falha anual de 13,4%; enquanto os dentes vitais apresentaram 28,1% de falha com uma taxa de falha anual de 6,6%. A regressão de Cox revelou associação entre marca comercial do compósito, classe da restauração e vitalidade pulpar com falha das restaurações. Conclui-se que restaurações de resina composta demonstraram um desempenho clínico satisfatório ao longo do tempo, apresentando sucesso em 70,6% dos casos em uma média de 4,8 anos, sendo que as de classe III apresentaram melhor desempenho clínico que classe V e classe IV e as restaurações em dentes desvitalizados apresentaram 2,37 vezes mais risco de falhas que restaurações em dentes vitais. Os principais motivos de falha para todos os tipos de restauração foi por fratura e/ou perda de retenção. Os dois métodos (USPHS e FDI) se demonstraram eficazes no processo de avaliação clínica em restaurações em dentes anteriores. / The aim of this study was to evaluate direct composite restorations Class III, IV, V in anterior teeth and premolars through the USPHS and FDI methods. Eighty-seven patients were selected through a search of the patients’ records present in the School of Dentistry. Restorations performed between 2000 to 2013 which a minimum of six months in mouth were selected. Adult patients of both sexes were included, who received treatment with restorations class III, IV or V with the follow composites: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic and Opallis; all restorations with total etch adhesive system; on vital and non-vital teeth. Patients with poor oral hygiene or special needs were not included in the study. Clinical evaluation was performed by USPHS and FDI modified methods, by one calibrated examiner. The survival of the restorations was analyzed using the Kaplan-Meier method and log-rank test to compare the groups, and multivariate Cox regression and hazard ratio were employed to identify factors associated with the failure of the restorations. The significance level was 5%. 272 restorations were evaluated with a time interval in service from 8 months to 13 years (mean 4.8 years). 120 class III restorations were evaluated, among them, 15 had failures (12.5%), with an annual failure rate of 2.74%. For the class IV type, 80 restorations were evaluated, 38 demonstrated failures (47.5%), with an annual failure rate of 12.6%. And for the class V, 72 restorations were analyzed, being observed the presence of failures in 27 of them (37.5%), with annual failure rate of 9.3% .The most common reason for failure was fracture or retention loss, for the three types of classes, occurring in 73 cases. Non-vital teeth showed 50% of failure in an average of 4.8 years, with an annual failure rate of 13.4%; while the vital teeth showed 28.1% of failure, with an annual failure rate of 6.6%. Cox regression revealed an association between brands, class type and tooth vitality with failures of the restorations. It was concluded that composite restorations showed a satisfactory clinical performance over time, with success in 70.6% of cases in a mean time of 4.8 years. Class III showed better clinical performance than class IV and V. Non-vital teeth restorations had 2.37 times the risk of failures than vital teeth. The main reasons for failure for all types of restoration was fracture and / or retention loss. Both methods (USPHS and FDI) demonstrated efficient in the process of clinical evaluation for anterior teeth.

Page generated in 0.3611 seconds