Spelling suggestions: "subject:"dentaria"" "subject:"complementarias""
31 |
Influencia das espátulas metálicas e de plástico sobre a cor de resinas compostas adicionadas ou não de substâncias radiopacificadorasSena, Suene Caldeira de January 1976 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-15T19:50:21Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T13:13:24Z : No. of bitstreams: 1
310127.pdf: 1368796 bytes, checksum: 46c2faeab35a260114d7540fec88428d (MD5)
|
32 |
Estudo comparativo in vitro de colagens de fragmento em incisivos superiores permanentes atraves de quatro tecnicas distintasOliveira, Marta Dutra Machado January 1994 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-16T06:35:52Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T18:35:56Z : No. of bitstreams: 1
94771.pdf: 1900164 bytes, checksum: 6eaf7b4b0a69efe8a63aa60cdc0dff8b (MD5) / Em quarenta dentes incisivos superiores permanentes, divididos em quatro grupos, foram executadas fraturas iniciais, as colagens de seus fragmentos e fraturas finais, de forma padronizada. Cada grupo foi restaurado, respectivamente, com resina composta quimicamente polimerizável (Grupo 1), resina composta fotopolimerizável (Grupo 2), resina composta quimicamente polimerizável conjugada à resina composta fotopolimerizável sobre bisel (Grupo 3) e cimento ionomérico fotopolimerizável conjugada à resina composta fotopolimerizável sobre bisel (Grupo 4). Após a análise dos resultados das forças necessárias à obtenção das fraturas iniciais e após as colagens, foi encontrado, para o Grupo 1, o valor médio de 19,94%, correspondendo ao restante de resistência do seu total. Para o Grupo 2, o valor médio de resistência final foi de 28,61%, bem como os valores de 60,53% e 34,43%, para os Grupos 3 e 4. Tais resultados demonstraram não serem as colagens de fragmento técnicas reprodutoras fiéis da resistência inicial de um dente, bem como a forma usada para a restauração dos dentes do Grupo 3, constatada como a mais eficiente.
|
33 |
Avaliação da infiltração marginal em preparos classe II MOD para inlays de resina composta : um estudo in vitroZanini, Sergio Eduardo Mesquita January 1997 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-17T03:11:20Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T22:06:34Z : No. of bitstreams: 1
148734.pdf: 2134426 bytes, checksum: 63c69243a6d072810a5154e187f782be (MD5) / Este trabalho teve como objetivo avaliar comparativamente o selamento marginal em esmalte e dentina e cavidades Classe II MOD, preparadas em dentes permanentes extraídos e restaurados com inlays de resi. composta. Os espécimes foram divididos em 4 grupos de 20, os quais receberam término de prepa diferenciado. Os resultados mostraram que houve uma maior infiltração marginal na dentina que esmalte em todos os grupos. Em esmalte e dentina, não houve diferença estatisticamente significante nível de infiltração marginal entre os diferentes tipos de preparo.
|
34 |
Influencia da tecnica de inserção no grau de adaptação cervical de restaurações de resina composta (classe II) em molares deciduos : um estudo clinicoRastelli, Flavia Pilatti January 1998 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-17T07:38:26Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T00:31:27Z : No. of bitstreams: 1
148116.pdf: 7287611 bytes, checksum: 334ffb3e1ab5640580286b6d62788f88 (MD5) / Este trabalho teve como objetivo avaliar o comportamento clínico, radiográfico e o grau de infiltração marginal nas paredes cervicais de restaurações de classe II em molares decíduos, utilizando-se 3 diferentes técnicas de inserção de resina composta. Depois de 12 meses na cavidade bucal, os resultados clínicos e radiográficos foram satisfatórios. A avaliação quantitativa da penetração de corante nas margens cervicais evidenciou a presença de algum grau de infiltração em todos os grupos, sem diferença estatisticamente significantes entre os mesmos.
|
35 |
Avaliação da influência da estratégia adesiva sobre a estabilidade de união resina-cerâmicaSilva, Daniel Baptista da 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-24T23:20:40Z (GMT). No. of bitstreams: 1
284172.pdf: 1008551 bytes, checksum: d5ec5dea42c1646fcf57d2d42c89e951 (MD5) / O objetivo do estudo foi avaliar a estabilidade da união entre resina e cerâmica. Foram utilizados dois ácidos, fosfórico (H3PO4) e fluorídrico (HF), e três silanos, dois contendo monômeros funcionais acídicos, Clearfil Ceramic Primer (CCP) e Porcelain Liner M (PLM), e um convencional, Rely X Ceramic Primer (RLX). Cinco blocos cerâmicos IPS e.max Press medindo 11 mm de comprimento, 9 mm de largura e 4 mm de altura foram confeccionados e polidos com lixas d'água em ordem decrescente de granulação - 220, 360, 600 - sob irrigação, jateados (10 s) com óxido de alumínio (50 ?m) sob 42 psi de pressão e limpos em ultrassom com água (10 min.). Na sequência, os blocos foram aleatoriamente divididos em grupos (n=30) e designados para os seguintes tratamentos de superfície: Controle (C) HF+RLX; (G1) HF+PLM; (G2) HF+CCP; (G3) H3PO4+CCP; e (G4) H3PO4+PLM. Sobre a superfície tratada, aplicou-se o adesivo Single Bond 2 (3M ESPE), no grupo C, e Clearfil SE Bond (Kuraray), nos demais. Após, cada bloco recebeu quatro incrementos de 1 mm de resina composta Filtek Z350 (3M ESPE). Os blocos de resina-cerâmica foram seccionados, obtendo-se corpos de prova de aproximadamente 0,8 mm x 0,8 mm de área. Cada grupo foi subdividido de acordo com o armazenamento: subgrupo i - imediato (24 h de armazenamento em saliva artificial); e subgrupo a - envelhecido (3 meses em saliva artificial + 5.000 ciclos de termociclagem - 5 ºC/55 ºC). Realizaram-se os testes de microtração com velocidade de 0,5 mm/min na máquina de teste universal Instron Machine (3M). Os padrões de fratura foram analisados em Microscópio Eletrônico de Varredura. Os resultados foram analisados pelos testes ANOVA Three-way e Tukey (? ? 0,05). As médias ± desvio padrão foram: Ci=30,11±14,57a; Ca=21,71±7,08a; G1i=28,85±11,47aA; G1a=25,64±6,69aA; G2i=36,12±16,99aA; G2a=22,92±8,00bA; G3i= 27,28±9,76aA; G3a=9,83±3,44bB; G4i=29,72±14,09aA; e G4a=16,76±5,52bB. Concluiu-se que o uso da estratégia adesiva com monômeros funcionais acídicos não influenciou a união entre resina e cerâmica, após armazenagem em saliva seguida de termociclagem.
|
36 |
Influência de diferentes estratégias adesivas e do tipo do isolamento do campo operatório (absoluto versus relativo) no desempenho clínico de restaurações com resina composta em lesões cervicais não cariosasCunha, Eduardo Marinho Daudt da 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T07:40:23Z (GMT). No. of bitstreams: 1
284314.pdf: 7573505 bytes, checksum: da95b211835f64a112ad52deec6a3efd (MD5) / Este estudo teve como objetivo avaliar o desempenho clínico de lesões cervicais não cariosas (LCNC) restauradas com diferentes estratégias adesivas: condicionamento ácido e autocondicionante, e comparar se o tipo do isolamento do campo operatório: absoluto ou relativo pode influenciar na durabilidade das restaurações por um período de 180 dias. Cento e quarenta lesões foram selecionadas em 38 pacientes de acordo com os critérios de inclusão/exclusão previamente estabelecidos, e distribuídas em quatro grupos (n=35) : G1 e G2: condicionamento ácido total e Adper Single Bond 2. G3 e G4: autocondicionante Adper SE Plus. O isolamento absoluto foi utilizado alternadamente em todo os grupos. Todos os procedimento restauradores foram realizados com a resina composta Z 350 por meio da técnica incremental, por um único operador. As 140 restaurações foram avaliadas pelo método direto USPHS modificado, por dois examinadores previamente calibrados, em 4 períodos distintos: imediato (até 24hs após a conclusão do procedimento restaurador) 7, 30, 180 dias. Os dados foram submetidos ao teste estatístico de McNemar para verificar possíveis alterações no índice Alfa dentro dos grupos em cada momento de avaliação. Para analisar a associação entre os grupos, foi utilizado o teste do Qui-quadrado, com nível de significância de 5%. Os resultados revelam que as duas estratégias adesivas promoveram uma queda efetiva na sensibilidade durante todo o período avaliador. Não houve diferença estatística para as estratégias adesivas ou as técnicas de isolamento, salvo o critério de descoloração marginal, onde 4 restaurações do G4 apresentaram escores bravo.
|
37 |
Microinfiltração marginal em restaurações adesivasHeiderscheidt, Elizabeth da Cunha January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-25T21:48:12Z (GMT). No. of bitstreams: 1
301892.pdf: 9913931 bytes, checksum: 6d5afa7aa0392841874f0fbfacfc66e7 (MD5) / Apesar da evolução nas características físico-mecânicas das resinas compostas, a contração gerada pela reação de polimerização continua sendo uma desvantagem, podendo levar a infiltração marginal e respostas pulpares adversas. Nesta pesquisa foi avaliado o efeito do uso de resinas compostas com baixa contração no índice de microinfiltração marginal em esmalte e dentina de restaurações Classe II. Para isso, em 60 pré-molares hígidos extraídos foram preparadas cavidades Classe II MOD padronizadas, com limites gengivais em dentina e esmalte. Os dentes preparados foram divididos em 6 grupos e restaurados com uma resina controle (G1- Filtek® Z350) ou uma de cinco resinas de baixa contração (G2- Filtek® Z350 XT; G3- Charisma® Opal; G4- IPS Empress® Direct; G5 - Tetric® N-Ceram e G6- Filtek® P90 à base de silorano). Todas foram utilizadas seguindo as recomendações de cada fabricante. Após 7 dias de armazenamento em água destilada, os espécimes foram submetidos a 500 ciclos térmicos (5°C a 55°C). Todas as superfícies foram impermeabilizadas com esmalte cosmético, deixando 1mm livre nas margens da restauração, e os protocolos para imersão em solução de nitrato de prata amoniacal foram seguidos. As amostras foram então seccionadas em sentido mésio-distal, fotografadas, e a porcentagem de microinfiltração marginal foi definida por meio de software específico. Os valores foram analisados estatisticamente pelos testes ANOVA e KrusKal-Wallis (p<0,05). Os resultados mostraram que em todos os grupos houve microinfiltração em esmalte e/ou dentina, com maiores índices em dentina. Em esmalte não houve diferença estatisticamente significativa entre os grupos, já em dentina os menores índices de microinfiltração foram obtidos por Filtek® P90. / Despite the progress in physical and mechanical properties of composites, the contraction generated by the polymerization reaction remains a disadvantage and can lead to leakage and adverse pulpal reactions. This study assessed the effect of the use of low shrinkage composite resins in the rate of marginal microleakage in enamel and dentin of Class II restorations. Thus, in 60 caries-free extracted premolars standardized Class II MOD cavities were prepared, with gingival floors on dentin and enamel. The prepared teeth were divided into 6 groups and restored with a control microhybrid resin (G1- Filtek® Z350) or one of five low shrinkage resins (G2- Filtek® Z350 XT; G3- Charisma® Opal; G4-IPS Empress® Direct; G5 - Tetric® N-Ceram and G6- Filtek® P90 silorane based). All were used following each manufacturer recommendations. After 7 days of storage in distilled water, the specimens were subjected to 500 thermal cycles (5°C to 55°C). All tooth surfaces were sealed with nail varnish to within 1mm from the restoration margins and protocols for immersion in ammoniacal silver nitrate were followed. The samples were then sectioned mesiodistally, photographed, and the percentage of microleakage was defined by means of specific software. Data were statistically analyzed with ANOVA and Kruskal-Wallis tests (p <0.05). Results revealed that all groups showed microleakage in enamel and/or dentin, with the highest rates in dentin. Evaluating the enamel margins there was no statistically significant difference between the groups, however the lowest microleakage rates in dentin were obtained by G6.
|
38 |
Ação de placas resilientes na atividade eletromiográfica dos músculos masseter e temporal anterior em pacientes com bruxismoTavares, Rui January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T22:35:18Z (GMT). No. of bitstreams: 1
299850.pdf: 1857303 bytes, checksum: ad4782dca30abdd09a43de5af3fa63fa (MD5) / A utilização de placas interoclusais rígidas consagra-se na prática odontológica diária e nos resultados da pesquisa científica como o método mais eficaz no controle do bruxismo. Entretanto, circunstâncias como o risco de prejudicar o desenvolvimento das estruturas mastigatórias ou crânio-faciais em crianças contra-indicam ou limitam o seu uso. Esta limitação das placas interoclusais rígidas e o fato de existirem dúvidas quanto às conseqüências musculares provocadas pelo uso de placas resilientes levaram à avaliação através de eletromiografia (EMG), da atividade muscular do masseter e do temporal anterior em posição postural de repouso e apertamento máximo da mandíbula, antes e após o uso de placas interoclusais totais resilientes ajustadas ou não em RC e com guias de desoclusão anterior e canina. Foram realizadas EMGs bilaterais dos músculos masseter e temporal anterior nas posições de repouso postural e de apertamento máximo da mandíbula antes da instalação da placa, após 28 dias de uso da placa não ajustada e após 28 dias de uso da placa ajustada, em 20 pacientes com bruxismo sem sinais ou sintomas de DTM, de ambos os sexos e com idade entre 09 e 29 anos. Os resultados demonstram que em relação aos músculos temporais anteriores, as placas interoclusais resilientes ajustadas provocaram significante (p=0,015) diminuição da atividade eletromiográfica apenas para o lado direito quando comparadas às placas não ajustadas, e anularam a diferença significante que havia entre a atividade eletromiográfica do músculo temporal anterior direito e esquerdo observada no exame inicial e naquele realizado após o uso da placa não ajustada. Quando a atividade dos músculos foi analisada em conjunto, as placas interoclusais resilientes ajustadas provocaram a diminuição significante (p=0,035) da atividade eletromiográfica quando comparada ao uso da placa resiliente sem ajuste. Para os músculos masseter, as placas interoclusais resilientes independentemente de estarem ajustadas ou não, provocaram diminuição da atividade eletromiográfica quando comparada ao exame inicial com significância (p=0,019) apenas para o lado esquerdo. Esta última análise mostrou ainda que o uso de placas interoclusais resilientes ajustadas resultou em diminuição significante (p=0,043) da atividade eletromiográfica quando comparada ao exame inicial. Havendo indicação do uso de placas interoclusais resilientes, as mesmas devem ser ajustadas em relação cêntrica e com guias de desoclusão anterior e canina.
|
39 |
Resistência de união de cimentos resinosos à cerâmicaBasso, Gabriela Romanini January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T03:16:21Z (GMT). No. of bitstreams: 1
301201.pdf: 5259834 bytes, checksum: 64859a4ef066bb128d6a85ee91f03780 (MD5) / Avaliar através do teste de microcisalhamento, a resistência de união entre discos de cerâmica usináveis reforçados com leucita, cimento resinoso de condicionamento ácido total e dois tipos de cimentos auto-adesivos. Quanto ao material e método, foi utilizada a cerâmica IPS Empress CAD (Ivoclar Vivadent AG) e os cimentos autoadesivos RelyX U100 (3M ESPE), Maxcem Elite (Kerr Corp) e como controle o cimento resinoso de condicionamento ácido total RelyX ARC (3M ESPE). Foram formados 6 grupos de acordo com o sistema de cimentação e o processo de envelhecimento: G1- RA, G2- RA+T, G3- RU, G4- RU+T, G5- ME, G6- ME+T. Metade das amostras foram submetidas ao teste imediatamente após o procedimento de cimentação e a outra metade foi armazenada em ambiente úmido por 24h a 37°C e submetida a 500 ciclos de termociclagem (5-55ºC). Após esta etapa, as amostras foram submetidas ao teste de microcisalhamento em uma máquina de ensaio universal Instron, Modelo 4444 (Instron, Canton, MA, USA) com velocidade de cruzeta de 0,5mm/min até a falha. O tipo de fratura foi determinado por meio da utilização de um microscópio óptico. Os resultados mostraram que o tipo de cimento, quando analisados separadamente, apresentam diferenças estatísticas. O que obteve os maiores resultados foi o RelyX ARC, seguido do RelyX U100 e, depois, o cimento Maxcem Elite. A maioria das falhas foram adesivas, para ambos os grupos. A termociclagem não interferiu negativamente a resistência de união dos cimentos RelyX U100 e RelyX ARC. Nas condições testadas, os cimentos autoadesivos não são tão eficientes quanto a resistência de união quanto os cimentos de condicionamento ácido total. / The aim of the study was to evaluate the microshear bond strength between leucite ceramic discs, cemented with: a total etching resin cement and two self-adhesive cements. Materials and methods: IPS Empress CAD (Ivoclar Vivadent AG) ceramic was applied, and self-adhesive cements: RelyX U100 (3M ESPE), Maxco (Kerr Corp) and as the control group, the cement RelyX ARC (3M ESPE). Six groups were formed according to their luting agent and
aging process. Half of the samples were subjected to the test immediately after the cementing procedure and the other half were stored in a humid environment for 24 hours at 37 ° C, subjected to 500 cycles of thermocycling (5-55 ° C). Afterwards, the samples were submitted to microshear testing in a universal testing machine Instron Model 4444 (Instron, Canton, MA, USA) with a crosshead speed of 0.5 mm / min until failure. The failure mode was determined using an optical microscope. Results showed that the microshear bond strength was influenced by the type of cement, and when analyzed separately, has statistical differences between groups. RelyX ARC showed the best results, followed by RelyX U-100, and Maxco afterwards. Most failures were adhesive for both groups. The thermocycling did not affect the bond strength between the cements RelyX U100 e RelyX ARC.
|
40 |
Avaliação da resistência ao desgaste abrasivo de resinas compostas universaisFerreira, Kazuza Bueno January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-23T04:36:43Z (GMT). No. of bitstreams: 1
240718.pdf: 16827340 bytes, checksum: e14907b15a3d3f3305fd3177beba3780 (MD5) / O objetivo desse estudo, in vitro, foi avaliar a resistência ao desgaste abrasivo das resinas compostas universais Charisma/CH (Heraeus Kulzer), Esthet-X/EX (Dentsply Caulk), Fill Magic/FM (Vigodent), Filtek Supreme/SU (3M ESPE), Filtek Z100/ Z1 (3M ESPE), Filtek Z250/Z2 (3M ESPE), Herculite XRV/HE (Kerr Dental), Opallis/OP (FGM), Te-econom/TN (Ivoclar Vivadent) e Tetric Ceram/TC (Ivoclar Vivadent). Foram confeccionados 8 corpos-de-prova, na cor A2, com formatos cilíndricos (8,0 mm de diâmetro X 2,0 mm de espessura) de cada material. A resistência ao desgaste abrasivo foi avaliada através de análises das alterações na massa e na rugosidade superficial das amostras submetidas à escovação simulada. As mensurações iniciais (pré-escovação simulada) e finais (pós-escovação simulada) de massa foram obtidas através de balança eletrônica com precisão de 0,0001g. As aferições iniciais e finais da rugosidade superficial foram feitas com uma sonda mecânica de 5µm acoplada ao rugosímetro Perthometer S8P (Mahr), com velocidade constante de 0,15mm/s e força de 0,8mN, utilizando o parâmetro de medição Ra expresso em µm, com cut-off de 0,25mm e comprimento de avaliação de 1,25mm. O teste abrasivo foi realizado em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e pontas arredondadas, sob 200g de carga, com velocidade de 374 ciclos/min e solução de dentifrício e água deionizada na proporção de 1:2. As amostras foram submetidas a 50.000 ciclos de escovação. As escovas foram substituídas a cada 25.000 ciclos e a solução foi constantemente reposta durante o teste. Para a avaliação das alterações decorrentes do teste abrasivo foram calculadas as diferenças entre as médias finais e iniciais de massa e de rugosidade superficial e os valores obtidos foram convertidos em porcentagem. Os dados foram analisados estatisticamente através dos testes t pareado, ANOVA, Scheffé e correlação de Pearson (p<0,05). Os resultados demonstraram que todos os materiais apresentaram redução estatisticamente significante da massa e aumento estatisticamente significante da rugosidade superficial após a escovação simulada (p < 0,0001). Considerando as alterações na massa, a ordem crescente de resistência à abrasão dos materiais avaliados foi (OP=Z2) > Z1 > TC > (HE=CH) > FM > TN > SU > EX. Com relação às alterações na rugosidade superficial, a ordem crescente de resistência à abrasão dos materiais avaliados foi EX > (HE = SU = TC = CH = FM) > (TC = CH = FM = OP) > (OP = Z2 = TN = Z1). Os métodos de avaliação de resistência ao desgaste não possuem correlação. Com base nos resultados concluiu-se que dentre as resinas compostas universais avaliadas existem diferenças na resistência à abrasão, entretanto, todas desgastam e ficam mais rugosas em conseqüência de forças abrasivas por escovação simulada. As alterações de massa e de rugosidade superficial das resinas compostas não estão correlacionadas.
|
Page generated in 0.1791 seconds