• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 278
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 281
  • 115
  • 107
  • 104
  • 101
  • 80
  • 78
  • 70
  • 64
  • 41
  • 35
  • 35
  • 35
  • 30
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Influência da reconstrução do preparo na resistência à compressão de inlays cerâmicas obtidas pela tecnologia CAD/CAM

Sinhori, Bruna Salamoni January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-09-01T04:09:09Z (GMT). No. of bitstreams: 1 333944.pdf: 1637622 bytes, checksum: 10299d678913cccd2ec0ef69fb00afb5 (MD5) Previous issue date: 2015 / O objetivo do presente estudo foi avaliar se a resistência à compressão de inlays cerâmicas à base de dissilicato de lítio apresenta diferença quando suportadas por um preparo realizado exclusivamente no substrato dental e quando suportadas por um preparo reconstruído com resina composta, e comparar a resistência à compressão desses grupos testados com dentes hígidos. Foram selecionados 30 terceiros molares superiores hígidos, divididos aleatoriamente em três grupos (n=10). Os preparos classe II-MOD realizados foram padronizados com abertura vestibulolingual seguindo dois terços da distância intercuspídea para largura do istmo e dois terços da distância do equador protético, mensuradas no sentido vestibulolingual para caixas proximais, variando entre os grupos apenas a extensão do preparo. Para o G2 o preparo foi realizado somente em estrutura dental, e o G3 teve a porção pulpar do preparo reconstruída com resina composta (incrementos de 2 mm) IPS Empress Direct (Ivoclar Vivadent). Ambos G2 e G3 receberam inlays cerâmicas de dissilicato de lítio IPS e.max CAD (Ivoclar Vivadent), realizadas pelo sistema CAD/CAM, que foram cimentadas com Variolink II (Ivoclar Vivadent) e que, juntamente com o G1 (controle-dente hígido), foram submetidos ao teste de resistência à compressão a uma velocidade de 1 mm/min. A resistência à fratura do grupo controle G1 (3276,14 N) foi estatisticamente superior à dos grupos G2 (1971,71 N) e G3 (1707,82 N), ao passo que não houve diferenças estatísticas entre os dois últimos grupos. Os dois grupos testados, restaurados com dissilicato de lítio, não restabeleceram a resistência do dente hígido, contudo apresentaram valores de resistência à fratura equivalentes estatisticamente e suficientes para suportar as forças mastigatórias fisiológicas, portanto a reconstrução do preparo deve ser considerada.<br> / Abstract : The aim of this study was to evaluate the influence of the substrate type (dentin or composite resin) on the compressive strength of lithium dissilicate ceramic inlays. Thirty human extracted maxillary third molars were selected and randomly ascribed to three groups (n=10). Standardized Class II MOD preparations were made (bucco-palatal width = 2/3 of the intercuspal width and 2/3 of the width at the tooth equator for the proximal boxes, with varying extensions of the preparations (Group 2: preparation limited to tooth structure; Group 3: pulpal floor of the preparation rebuilt with composite resin, IPS® Empress Direct (Ivoclar Vivadent), restored with lithium dissilicate CAD/CAM ceramic inlays e.max CAD (Ivoclar Vivadent), and cemented with a resin cement Variolink II (Ivoclar Vivadent). All groups were subjected to compressive strength test (1mm/min crosshead speed). The results have shown that the fracture strength of control group G1 (3271,71 N) was statistically significantly higher than G2 (1971,71 N) and G3 (1707,82 N), while these groups were not statistically different. Both groups restored with lithium dissilicate restorations did not reach the fracture strength of the sound teeth, but were statistically equivalent and sufficient to withstand physiologic masticatory forces, so the reconstruction of the preparation should be considered.
32

Avaliação in vitro da influência de quatro tratamentos de superfície na resistência de união à tração de uma liga de Ni-Cr e de duas resinas compostas

Becker, Mirian Marly January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2013-07-15T22:44:51Z (GMT). No. of bitstreams: 0 / O presente trabalho avaliou, in vitro, a resistência adesiva por tração de um cimento resinoso à superfícies de uma liga de metal e de duas resinas compostas em função de diferentes tratamentos de superfície. Os resultados demonstraram comportamentos diferentes conforme o material avaliado; o jateamento com (CoJet® Sand) foi o tratamento mais efetivo para o metal; a asperização com ponta diamantada + ácido fosfórico, o jateamento com CoJet Sand e o jateamento com partículas de óxido de alumínio mostraram resultados eqüivalentes na resina composta de consultório; a asperização com ponta diamantada + ácido fosfórico foi o tratamento de superfície mais eficaz para a resina composta de laboratório, seguido pelo jateamento com (CoJet Sand); e, o tratamento de superfície com ácido fluorídrico resultou como o pior tratamento de superfície para todos os materiais testados.
33

Avaliação da resistência de união de sistemas adesivos auto-condicionantes à dentina

Arruda, Carlos Eduardo Pinarel January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T17:00:17Z (GMT). No. of bitstreams: 1 186156.pdf: 918336 bytes, checksum: d8ff1ad82bf2aa41e802c710a1f41b51 (MD5) / O objetivo deste trabalho foi avaliar a resistência de união de três sistemas adesivos em dentina. Os espécimes foram divididos aleatoriamente em três grupos segundo o sistema adesivo a ser utilizado, e submetidos ao ensaio de cisalhamento, a uma velocidade de cruzeiro de 1,0mm/min. Os valores médios de resistência obtidos foram de 23,07 MPa para o sistema adesivo Single Bond, 20,80 MPa para o sistema adesivo One Up Bond F e de 35,68 MPa para o sistema adesivo Clearfil SE Bond. Concluiu-se que o sistema adesivo Clearfil SE Bond apresentou média de resistência ao cisalhamento superior as médias obtidas pelos sistemas One Up Bond F e Single Bond, sendo que estes não tiveram diferença estatisticamente significante entre suas médias.
34

Influência do clareamento dental, com gel de peróxido de carbamida a 10%, na adesão ao esmalte humano, de um adesivo monocomponente com solvente a base de etanol

Schubert, Edward Werner January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Gradução em Odontologia. / Made available in DSpace on 2012-10-19T19:22:36Z (GMT). No. of bitstreams: 1 186444.pdf: 1463883 bytes, checksum: 98f3da0ede1b3184cc0a5025fdb86ac7 (MD5) / O objetivo foi observar as possíveis modificações provocadas pelo clareamento dental à base de peróxido de carbamida a 10%, sobre o esmalte dental humano, na força de adesão de um adesivo dentinário monocomponente.. O clareamento na boca durante todo o período experimental de 21 dias, sendo exposto ao agente clareador durante 3h diariamente. Após o período experimental, os corpos de prova, ficaram em repouso por 24h. O esmalte foi ácido condicionado, hibridizado e fotopolimarizado. Na seqüência os blocos foram transformados em palitos com superfície de 1mm2), e foram submetidos ao teste de tração,. Os resultados, após análise estatística demonstraram que não houve diferença estatisticamente significante entre os grupos testados.
35

Influência do tipo de restauração adesiva na resistência de pré-molares superiores

Cyrino, Lisiane Cribari Rangel January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T23:29:41Z (GMT). No. of bitstreams: 1 184448.pdf: 982300 bytes, checksum: 38c201c35133f6b9a91539c655d937b5 (MD5) / Reporta a resistência à fratura de pré-molares superiores com preparos cavitários MOD, com istmo de ¼, restaurados com amálgama utilizando a técnica adesiva (Scotchbond Multipurpose Plus -3M - Co) + Amálgama (Permite C - SDI). e resina composta direta (Z 250 -3M - Co) para dentes posteriores. Dentes hígidos e dentes com preparo porém não restaurados foram usados para comparação. Restaurações utilizando as técnicas adesivas resina composta e amálgama adesivo restabeleceram a resistência à fratura dos dentes pré-molares extraídos, que receberam preparos cavitários classe II, tipo MOD.
36

Prevalência de contatos abertos em restaurações proximais de resina composta e amálgama executadas por dentistas e estudantes de Odontologia

Neves, Danielle Machado January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T07:55:12Z (GMT). No. of bitstreams: 1 187112.pdf: 388096 bytes, checksum: a36d9533d23dfd65aff908752259e2a3 (MD5) / O objetivo deste estudo foi avaliar a prevalência de contatos abertos em restaurações proximais de resina composta e amálgama executados por dentistas e estudantes de odontologia. Foram examinados pacientes adultos (homens e mulheres) entre 20 e 80 anos de idade, totalizando uma amostra de 200 pacientes (sendo 100 em consultórios particulares e 100 em faculdades). Dentes permanentes posteriores, pré-molares e molares de todos os hemiarcos foram examinados. Para a avaliação dos contatos abertos, fez-se uso de fio dental sem cera, e o contato era considerado aberto quando não fosse encontrado resistência com o uso do mesmo. O total de contatos entre restaurações examinados foi de 792, sendo 339 em consultórios particulares e 453 em faculdades. O total de contatos abertos encontrados foi de 22, sendo 16 em consultórios particulares e 6 em faculdades. Os contatos abertos mais encontrados estavam localizados entre os segundos pré-molares e molares na maxila (36,36%) e entre o primeiro e o segundo molares na mandíbula (27,27%), estando estes contatos abertos localizados entre amálgama e dente hígido (p<0,05).
37

Reparo apical e periapical em dentes de cães pós tratamento endodôntico em função do curativo de demora e de um novo cimento obturador. Importância do curativo de demora e do cimento obturador na infiltração apical in vitro

Silveira, Frank Ferreira [UNESP] 10 October 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-10-10Bitstream added on 2014-06-13T20:41:58Z : No. of bitstreams: 1 silveira_ff_me_arafo.pdf: 343768 bytes, checksum: e3d592d429f09319f3775639ceb1eefb (MD5) / O objetivo do presente trabalho foi avaliar um novo cimento obturador de canal radicular denominado comercialmente de Sealer Plus, de acordo com as seguintes metodologias. 1. Avaliação histológica em dentes de cães, após período experimental de 90 dias. Foram utilizados 60 canais radiculares de pré-molares de cães com vitalidade, os quais, após preparo biomecânico, foram obturados pela técnica clássica complementada pela condensação lateral utilizando o cimento Sealer Plus, sendo que no Grupo I os canais radiculares receberam um curativo de demora à base de hidróxido de cálcio por 7 dias, no Grupo II um curativo à base da associação corticosteróide-antibiótico pelo mesmo período e no Grupo III não foi empregado o curativo de demora. Decorridos 90 dias da obturação, os animais foram sacrificados por sobredose anestésica, as maxilas e mandíbulas foram removidas e fixadas em formol a 10%, durante 48 horas. Após o processamento histológico de rotina, os cortes foram corados pela hematoxilina e eosina e pelo tricrômico de Mallory. A análise histopatológica evidenciou que o cimento Sealer Plus quanto à compatibilidade tecidual mostrou-se insatisfatório independente da utilização ou não do curativo de demora. 2. Avaliação da infiltração marginal apical in vitro. Foram utilizados 120 incisivos centrais superiores de humanos extraídos e divididos em quatro grupos de 20 dentes cada, e 3 grupos de 10 dentes usados como controle, os quais foram inicialmente instrumentados com limas tipo K até o no 30 no comprimento real do dente... / The scope of this work was to evaluate a new root canal filling Sealer Plus by using the following methods: 1. Histological evaluation of dog teeth. Experimental period of 90 days. In this experiment, 60 premolar with pulp vitality were used and after biomechanical preparation were filled by classic technique using Sealer Plus completed by lateral condensation; in Group I the root canals were filled with calcium hydroxide intracanal dressing during seven days, in Group II antibiotic/corticosteroid dressing during the same period and Group III without intracanal dressing, After a 90- day period, the animals were sacrificed by anesthethic overdose and had their maxillaries and mandibles removed. The removed parts were fixed in 10% formalin for 48 hours. Following a routine histological process, the cuts were stained by hematoxilin, eosin and Mallory Tricromic. The histopathological analysis showed that the Sealer Plus cement were unsatisfactory in relation to the tissue compatibility. 2. Evaluation of the marginal apical infiltration. In this experiment, 120 extracted top-central human incisors in 4 groups of 20 teeth were used and 3 group of 10 teeth used as control groups. The teeth were initially filed with K file up to the number 30 until apical patency and root canal prepared up to the number 50, using sodium hipochloride 0,5%, After that, the root canal were filled with Sealer Plus or Grossman cements, using or no calcium hydroxide intracanal dressing. After the fillings, the teeth were unpermeated in al their extension with nail polishing, except for 1 to 2 mm around the apical forame, submerged in 2% metilen blue colouring under vacuum conditions and fractured in such a way to obtain 2 sections. The colouring penetration was measured by a perilometer and the data, after statistical analysis, there was no difference between the groups.
38

Influência da diabetes mellitus na resposta tecidual e na capacidade de mineralização dos cimentos Sealapex, MTA Angelus e MTA Fillapex

Queiroz, Índia Olinta de Azevedo [UNESP] 20 February 2013 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-20. Added 1 bitstream(s) on 2015-06-18T12:47:30Z : No. of bitstreams: 1 000831085.pdf: 459011 bytes, checksum: 667fcb4731d7d180af7b8334427157eb (MD5) / O objetivo deste estudo foi avaliar a influência da diabetes mellitus na resposta tecidual e na capacidade de mineralização dos cimentos Sealapex®, MTA Angelus® e MTA Fillapex®. Vinte e quatro ratos Wistar foram divididos em dois grupos: diabéticos e não diabéticos. A indução de diabetes foi feita por meio da aplicação do Aloxano. Cada animal recebeu três implantes de tubos de polietileno contendo os materiais a serem testados e mais um tubo vazio como controle. Seis animais de cada grupo receberam injeções dos fluorocromos Calceína (7º dia), Alizarina (14o dias) e Oxitetraciclina (21o dias) durante a fase experimental. Os tempos operatórios foram 07 e 30 dias, quando os animais foram mortos e os espécimes processados para análise histológica de hematoxilina e eosina, Von Kossa, luz polarizada e fluorescência. Resultados: No 7o dia, observou-se uma resposta inflamatória moderada entre todos os grupos e no 30o dia, verificou-se uma resposta inflamatória leve. Ambos os grupos diabético e não diabético apresentaram, aos 07 e 30 dias, com todos os materiais testados áreas de mineralização e estruturas birrefringentes à luz polarizada. Sealapex® e MTA Fillapex® apresentaram uma maior intensidade de fluorescência do que MTA Angelus® (p <0,05) para todos os fluorocromos no grupo não diabético e somente para alizarina e oxitetraciclina no grupo diabético. Não houve diferença entre o Sealapex® e o MTA Fillapex® para nenhum fluorocromo independente da condição diabética. A intensidade de fluorescência não se alterou com nenhum material nos ratos diabéticos. Conclusão: A diabetes mellitus não interferiu na resposta tecidual e na capacidade de mineralização do Sealapex®, MTA Angelus® ou MTA Fillapex® / Objective: The aim of this study was to evaluate the influence of diabetes mellitus on tissue response and mineralization ability of Sealapex® MTA Angelus® and MTA Fillapex® sealers. Methods: Twenty-four Wistar rats were divided into two groups: diabetics induced by Alloxan and non-diabetics. The materials were placed in the polyethylene tubes and implanted into dorsal connective tissue of rats for 7 and 30 days. Six animals from each group received injection with calcein on day 7, alizarin on day 14 and oxytretacycline hydrochloride on day 21. The animals were killed after 7 and 30 days and the specimens were prepared for histologic analysis with hematoxylin and eosin, Von Kossa technique, and not stained for polarized light or fluorescence. Results: On 7 days, it was observed similar inflammatory reactions among all groups characterized by a moderate inflammatory response and on 30 days, it was found a mild inflammatory response. Both materials groups exhibited positive structures on Von Kossa and Polarized light analysis either on 7 and 30 days. Sealapex® and MTA Fillapex® showed more fluorescence intensity than MTA Angelus® (p<0.05) for all fluorochromes in non-diabetic group and for alizarin and oxytretacycline in diabetic group. It was not observed difference between Sealapex® and MTA Fillapex® for all fluorochromes independently on the diabetic condition. Fluorescence intensity was not changed with any material in diabetic rats. Conclusion: It was concluded that diabetes mellitus did not influence the tissue response or mineralization stimulated by Sealapex® or MTA Angelus® or MTA Fillapex®
39

Influência da superfície dentinária bovina na resistência de união de sistemas adesivos

Lara, Rafael Alves de [UNESP] 12 February 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:49Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-12. Added 1 bitstream(s) on 2015-06-18T12:47:02Z : No. of bitstreams: 1 000826646.pdf: 221252 bytes, checksum: 07c2518fc0e0672138be32887f943210 (MD5) / O objetivo deste estudo foi avaliar o efeito da superfície dentinária bovina na resistência de união (RU) de dois sistemas adesivos. Em dois grupos (n = 5) o esmalte vestibular de incisivos bovinos foi removido até a exposição da camada intermediária de dentina. Nos outros dois grupos os dentes bovinos foram desgastados a partir da face lingual ultrapassando os limites da câmara pulpar expondo dessa forma a parede vestibular da câmara pulpar. Os dentes foram planificados e polidos em lixadeira rotatória com lixas nas granulações sequenciais e crescente de 120 até 600 a fim de padronizar a formação da smear layer. Os adesivos utilizados foram o Single Bond 2 (3M - ESPE) (SB2) e o ClearFill (Kuraray) (CF). Os dentes dos grupos tratados com SB2 e os tratados com CF tiveram um bloco de resina composta (TPH 3, Dentsply) construído sobre cada superfície tratada. Após armazenagem por 24 h em estufa 37 ºC, cada conjunto dente/restauração foi seccionado nos eixos X e Y (ISOMET 1000, Buehler) para obter espécimes em forma de palito, contendo 1 mm² de área de secção transversal. A RU foi obtida em teste de microtração em máquina de ensaio universal (EMIC DL-1000) utilizando-se o dispositivo de Geraldeli, a uma velocidade de 0,5 mm/min. As fraturas foram analisadas em estereomicroscópio e classificadas em duas categorias: Tipo I - fratura adesiva, Tipo II - fratura mista.Os valores de resistência de união (MPa) foram submetidos a análise de variância de 2 fatores e ao teste de Tukey para comparação entre os grupos, ambos com α = 0,05. Foram obtidos os seguintes valores: G1 (normal/convencional) = 43,9 ± 4,8 MPa; G2 (invertido/convencional) = 29,2 ± 5,4 MPa; G3 (normal/autocondicionante) = 13,9 ± 2,1 MPa e G4 (invertido/autocondicionante) = 12,7 ± 3,4 MPa, com significância para direção da dentina ,para os sistemas adesivos bem como para a interação dos fatores. Limitado pela metodologia do estudo pode se ... / The aim of this study was to evaluate the influence of bovine dentin surface on the bond strength (BS) of two adhesive systems. In two groups (n = 5) buccal enamel of bovine incisors was removed by exposing the middle dentin. In the other two groups bovine teeth were ground from the lingual surface exposing the buccal wall of the pulp chamber. The teeth were ground flat and polished on sequentially with # 120 to 600 sandpapers in order to standardize the smear layer. The adhesives were Single Bond 2 (3M - ESPE) (SB2) and ClearFill (Kuraray) (CF). A block of composite resin (TPH 3, Dentsply) was constructed on the adhesive treated surface. After storage for 24 hours at 37 °C, each set was sectioned in X and Y (ISOMET 1000, Buehler) axes to obtain i-shaped specimens, with 1 mm² cross sectional area. The BS was obtained by mechanical microtensile testing in a universal testing (EMIC DL - 1000) using the Geraldeli's device at cross head speed of 0.5 mm/min. The fractures were examined under a stereomicroscope and classified into two categories: Type I - adhesive fracture, type II - mixed fracture. Data of bond strength (MPa) were submitted to 2-way ANOVA and Tukey's test for comparison between groups, both with α = 0.05. With the average values for the groups tested as follows: G1 (normal/Conventional) = 43,9 ± 4,8 MPa, G2 (invert/conventional) = 29,2 ± 5,4 MPa; G3 (normal/self-etching) = 13,9 ± 2,1 MPa and G4 (invert/self-etching) = 12,7 ± 3,4 MPa with significance for the direction of the dentin for adhesive systems as well as for the interaction of factors. Limited by the methodology of the study it can be concluded that the direction of bonding influences on the bond strength primarily in self-etching adhesives
40

Avaliação quantitativa da continuidade da interface cimento/dentina de cimentos resinosos com diferentes modos de polimerização empregados na cimentação de pinos de fibra de vidro

Bonfante, Estevam Augusto 24 May 2005 (has links)
Vários fatores podem influenciar a integridade da interface cimento resinoso/dentina, na cimentação de pinos intra-radiculares. A dificuldade da luz fotopolimerizadora atingir as regiões mais apicais do conduto, os estresses da contração de polimerização, a incompatibilidade entre sistemas adesivos ácidos e os cimentos autopolimerizáveis e dual, variações anatômicas da raiz, dificuldades de de controle da umidade e as características do substrato dentinário radicular são fatores limitantes. Assim, o objetivo deste estudo foi analisar quantitativamente a continuidade da interface cimento/dentina, por meio de MEV, nas seguintes condições: após a cimentação, após a imersão em solvente MEK e após 3 meses de armazenagem em água. Pinos de fibra de vidro foram cimentados em quarenta incisivos bovinos com os cimentos Multilink, Variolink II, Enforce Dual e Enforce PV. Após cimentação, os espécimes eram seccionados longitudinalmente e réplicas eram preparadas para análise em MEV. Os mesmos espécimes foram imersos em MEK e novas réplicas eram confeccionadas. Em seguida, os espécimes eram armazenados em água por 3 meses, imersos em MEK e novas réplicas eram analisadas. Quantificou-se a proporção entre a interface total cimento/dentina e a interface que apresentava continuidade com o cimento. Valores significativamente inferiores de continuidade foram observados para o Multilink (8,25%) e Variolink II (10,08%), em comparação ao Enforce Dual (25,11%) e Enforce PV (27,60%). A mesma tendência foi observada após imersão em solvente, porém sem mudanças significativas. Após 3 meses, uma significativa queda na continuidade foi observada para Multilink, Variolink II, Enforce Dual e Enforce PV (3,31%, 1,87%, 1,20%, 0,75%, respectivamente). As falhas se situaram principalmente nos terços apical e médio antes e após imersão em solvente. Após 3 meses foram detectadas falhas também no terço cervical. / Quantitative analysis of continuity between cement/dentin interface of different activation mode resin cements, when luted to fiber posts. Many factors can influence the bond integrity of posts luted into root canals. These include the difficulty of curing light to reach the most apical areas of root canals, polymerization contraction stresses, incompatibility between acidic adhesives and auto/dual-cured composites, anatomical variations of the root, problems regarding access, moisture level control and the peculiar characteristics of the root dentin substrate. Thus, it was the aim of the present investigation to perform a quantitative analysis of the continuity between resin cements and dentin interfaces, by means of scanning electron microscopic (SEM) analysis, in the following situations: after cementation, after MEK immersion, and after a 3-month water storage period. Forty bovine endodontically-treated incisors were randomly assigned to be luted with a fiber post and the following cements: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and replicas were prepared for SEM analysis. The same halves were immersed in MEK, replicated and evaluated. After 3 months water storage, a new set of replicas of the same halves were made and again analysed. The ratio between the total available bonding interface and the dentin interfaces that presented continuity with resin cement was then calculated. Significant lower values of continuity were found for Multilink (8,25%) and Variolink II (10,08%) when compared to Enforce Dual (25,11%) and Enforce PV (27,60%). The same trend was observed after immersion in MEK, with no significant changes. However, a significant decrease in continuity was observed after 3 month water storage for Multilink, Variolink II, Enforce Dual and Enforce PV (3,31%, 1,87%, 1,20%, 0,75%, respectively). An analysis of failure location depicted the majority of gaps at the apical and middle thirds before and after immersion in MEK. After 3 months gaps were also detected at the cervical third.

Page generated in 0.0769 seconds