• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 278
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 281
  • 115
  • 107
  • 104
  • 101
  • 80
  • 78
  • 70
  • 64
  • 41
  • 35
  • 35
  • 35
  • 30
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da resistência à fratura de pré-molares com preparos cavitários médios e extensos restaurados com sistemas restauradores diretos

Pottmaier, Larissa Fernanda January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T17:54:29Z (GMT). No. of bitstreams: 1 326591.pdf: 8403901 bytes, checksum: f597519976d32e4f5908ad1fef41acfe (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar a resistência à fratura de pré-molares superiores, com preparos médios e extensos, restaurados. Setenta dentes pré-molares superiores, hígidos, foram aleatoriamente divididos em 7 grupos: G1 (grupo controle) - Dente hígido; G2, G2 e G3 receberam preparo classe II MOD com largura da caixa oclusal de 1/3 da distância intercuspídea, e foram restaurados com a resina Filtek Z350 XT, IPS Empress Direct e Charisma Diamond respectivamente; G5, G6 e G7 receberam preparo classe II MOD com largura da caixa oclusal de 2/3 da distância intercuspídea, e foram restaurados com a resina Filtek Z350 XT, IPS Empress Direct e Charisma Diamond respectivamente. Após o armazenamento em água a 37º C, os corpos de prova foram submetidos ao teste de fratura sob compressão em uma máquina de ensaio universal, onde as cargas foram aplicadas verticalmente com uma velocidade de 0,5mm/min. A análise estatística demonstrou que o G1 (dente hígido) apresentou uma resistência à fratura significativamente maior (p=0,005) que qualquer outro grupo experimental. Dentre os grupos experimentais, apenas o G5 (2/3 da distância intercuspídea, resina Filtek Z350 XT) apresentou resistência à fratura significativamente menor (p=0,019) em relação aos demais. Para as outras resinas, IPS Empress Direct e Charisma Diamond, o aumento da distância intercuspídea de 1/3 para 2/3 não reduziu significativamente (p>0,05) a resistência à fratura do conjunto dente-restauração. O preparo cavitário enfraquece a estrutura dental remanescente, entretanto sua resistência pode ser restaurada parcialmente por restaurações adesivas diretas.
52

Influência da limpeza pós-condicionamento e do método de secagem do silano sobre a união resina-cerâmica

Siedschlag, Gustavo January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-03-04T18:55:09Z (GMT). No. of bitstreams: 1 304974.pdf: 373000829 bytes, checksum: a030a66c698daa104aecb8ec6bb46db5 (MD5) / Objetivos: avaliar a influência da limpeza pós-condicionamento e do método de secagem do silano sobre a resistência de união à microtração (µTBS) entre cimento resinoso e cerâmica reforçada por di-silicato de lítio. Métodos: Pastilhas cerâmicas (IPS e.max CAD) foram tratadas com ácido hidrofluorídrico (HF) por 20 s e em seguida distribuídas em 06 grupos, de acordo com os protocolos de limpeza póscondicionamento e de secagem do silano (n = 30): 1) sem limpeza (SL) (água corrente 20 s) + silano não aquecido/23ºC (SNA) (SL/SNA - controle 1); 2) SL + silano aquecido/ar quente 100±5ºC, 1 min (SA) (SL/SA - controle 2); 3) spray ar-água 30 s (SAA) + SNA (SAA/SNA); 4) SAA + SA (SAA/SA); 5) SAA + ácido fosfórico 37% por 1 min/lavagem em água corrente 30 s (AF) + SNA (SAA/AF/SNA); 6) SAA + AF + SA (SAA/AF/SA). Após a cimentação com cimento resinoso, os espécimes foram armazenados (24 h, 37ºC) e preparados para o teste de microtração. Foram realizadas análise em MEV e EDX para determinação do modo de falha e caracterização da superfície cerâmica. Os dados foram analisados pelos testes ANOVA e Tukey HSD (a = 1%). Resultados: Houve influência significativa dos protocolos de limpeza pós-condicionamento, aquecimento do silano bem como a interação entre os dois na µTBS (p < 0.001). Os valores em MPa foram SL/SNA (0.0, D), SL/SA (11.3, C), SAA/SNA (32.3, A), SAA/SA (28.6, AB), SAA/AF/SNA (25.2, B), SAA/AF/SA (30.1, AB). O modo de falha foi predominantemente do tipo adesivo para os grupos sem limpeza, e misto para os grupos limpos com spray ar-água somente ou associado ao ácido fosfórico. A utilização adicional do AF após o SAA não melhorou a µTBS, comparado ao grupo limpo apenas com SAA, independentemente do método de secagem do silano. A análise em MEV revelou uma redução nas microretenções e porosidades superficiais nos grupos limpos com AF bem como a presença de novos resíduos salinos, caracterizados pela análise EDX. Conclusões: Os diferentes resíduos formados pela aplicação de ambos os ácidos (HF e AF) reduziram a µTBS para a cerâmica de di-silicato de lítio (IPS e.max CAD). O spray ar-água foi o método de limpeza pós-condicionamento mais efetivo na remoção dos resíduos e gerou as maiores médias de resistência de união. O aquecimento do silano não demonstrou ser um passo relevante na cimentação adesiva quando a cerâmica foi devidamente limpa. / Objectives: To evaluate the influence of post-etching cleaning and silane air-drying on the microtensile bond strength (µTBS) between resin cement and lithium di-silicate ceramic. Methods: Ceramic pallets (IPS e.max CAD) were treated with hydrofluoric acid (HF, 20s) and divided into 06 groups, according to the post-etching cleaning and silane air drying protocols (n=30): 1) no cleaning/tap water, 20s (NC) + silane not heat dried/23ºC (SNH) (NC/SNH - control 1); 2) NC + silane heat dried/warm air 100±5°C, 1 min (SH) ( NC/SH - control 2), 3) air-water spray 30 s (AWS) + SNH (AWS/SNH), 4) AWS + SH (AWS/SH), 5) AWS + 37% phosphoric acid brushed for 1 min (PA) + SNH (AWS/PA/SNH), 6) AWS + PA + SH (AWS/PA/SH). After cementation with resin cement, the blocs were stored (24 h, 37 ° C) and prepared for the microtensile test. SEM and EDX analysis was additionally performed to determine the failure mode and characterize the ceramic surface. Data were analyzed by ANOVA and Tukey HSD (a = 1%). Results: There was significant influence of the post-etching cleaning and silane drying protocols and the interaction between this two factors on the µTBS (p <0.001). The values (MPa) were NC/SNH (0.0, D), NC/SH (11.3, C), AWS/SNH (32.3, A), AWS/SH (28.6, B), AWS/PA/SNH (25.2, B ), AWS/PA/SH (30.1, AB). The failure mode was predominantly adhesive for groups NC/SNH and NC/SH and mixed for the others. The additional use of PA after AWS did not improve the µTBS compared to the group cleaned only with AWS, regardless of the silane air-drying protocol. SEM analysis revealed a reduction in microretentions and porosities at the groups cleaned with PA and the presence of new salt residues, characterized by EDX analysis. Conclusions: The different residues formed by the application of both acids (HF and PA) reduced the µTBS for the lithium di-silicate ceramic. The air-water spray post-etching cleaning protocol was more effective in removing the residues and generated the best mean bond strength. Silane heat drying shown not to be an important step for the adhesive cementation when the ceramic surface was properly cleaned.
53

Avaliação da resistência de união entre dentes de resina e bases de próteses em função de diferentes tratamentos de superfície

Bragaglia, Lauro Egídio January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2013-07-15T22:48:38Z (GMT). No. of bitstreams: 1 224777.pdf: 6747022 bytes, checksum: 6a8d7dea84f7ac8b0a1b2d095ce4abfb (MD5) / A união entre os dentes artificiais utilizados nas próteses e a base das mesmas ocasionalmente falha. O objetivo deste estudo foi comparar a resistência de união entre bases de prótese e dentes de resina acrílica submetidos a seis tratamentos de superfície: CT - controle, superfície não alterada; MN - aplicação de monômero; OA - asperização com jato de óxido de alumínio; BR - remoção do brilho superficial com broca esférica; PE - asperização com pedra montada de óxido de alumínio e; CV - confecção de cavidade. As médias de resistência em kgf dos grupos foram: CT: 18,19(7,14), MN: 18,34(5,28), OA: 23,82(5,40), BR: 23,30(4,79), PE: 25,39(7,80) e CV:17,48(7,17). Houve diferença estatisticamente significativa apenas entre os grupos PE (melhor resultado) e CV (pior resultado) (p=0,037997).
54

Análise da frequência de ressonância de implantes zigomáticos submetidos a função imediata/precoce

Magalhães Junior, Edival Barreto de January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-15T22:54:23Z (GMT). No. of bitstreams: 1 228112.pdf: 1275787 bytes, checksum: 79e019045ca71eb1c0e747afd40fbfdb (MD5) / O objetivo do estudo foi analisar a evolução da freqüência de ressonância de implantes zigomáticos submetidos a função imediata/precoce (teste) num período de 06 meses, em pacientes com maxila severamente absorvida e, compará-los com a estabilidade dos implantes zigomáticos que tiveram função tardia (controle), e ainda, compará-los com implantes convencionais instalados na região anterior da maxila. Foram avaliados 09 pacientes e mensurados um total de 50 implantes, sendo 18 zigomáticos e 32 convencionais. Os registros foram realizados no momento da instalação do implante (0 dia), em 90 dias e 180 dias para o grupo teste, e, 0 e 180 dias para o controle. No grupo teste, os valores médios da análise da freqüência de ressonância dos implantes zigomáticos na instalação foi de 61,3 ± 18,91 ISQ (quoeficiente de estabilidade do implante), 90 dias após foi de 62,56 ± 9,38 ISQ e em 180 dias, a média foi de 69,44 ± 6,12 ISQ. Não houve diferença estatística comparando 0 e 90, e 0 e 180, porém houve diferença estatisticamente significante para 90 a 180 dias. Foram perdidos 01 implante zigomático e 3 convencionais. No grupo controle, a média ISQ foi de 59,88 no dia da instalação e 61,25 180 dias após. Os valores de freqüência de ressonância dos implantes zigomáticos submetidos a carga imediata/precoce apresentaram uma elevação contínua durante todo o período estudado, e registraram valores médios superiores aos tardios, tanto na instalação quanto 180 dias após. Na comparação entre os tipos de implantes localizados na região posterior (zigomático) e anterior (convencional) da maxila, não houve diferença estatisticamente significante. O estudo apresentou uma taxa de sobrevivência para os implantes zigomáticos teste e controle após 180 dias, de 90% e 100%, respectivamente. The purpose of this clinical study was to evaluate during 06 months, in patients with severe resorbed maxilla, the stability of immediate/early loading zygomatic implants (test) by means of resonance frequence analysis (RFA), compare the stability against delayed loaded zygomatic implants (control) and conventional implants in the anterior maxilla. RFA was used for direct measurement of implant stability of 18 zygomatic and 32 conventional implants in 09 patients. Each implant was tested for primary stability at the time of implant placement, after 90 days and 180 days following surgery. Control group was only assessed at placemet and 180 days. In the test group, the mean values of RFA was 61,3 ± 18,91, 62,56 ± 9,38 and 69,2 ± 6,12 implant stability quotient(ISQ), respectively at the placement, at 90 days, and 180 days. there was no statistically significant difference when was compared 0 to 90 , and 0 to 180, however, from 90 to 180 there was difference. One zygomatic implant and 03 conventional implants failed. In the control group, the mean ISQ values were 59,88 at placement and 61, 25 at 180 days. Resonance frequency analysis method showed a continuous increase of zygomatic immediate/early loading ISQ values during the study and the test group mean ISQ values were higher than the control group both at placement and 180 days after. When comparing implant position (length), i.e., zygomatic against conventional implants, there was no difference in the resonance frequency analysis. The clinical zygomatic implant survival rate during this study for the test and control group was 90% and 100%.
55

Avaliação da efetividade de diferentes técnicas de remoção do excesso de cimento resinoso e sua influência na microinfiltração marginal de restaurações indiretas

Ferreira, Isana Álvares January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T17:46:38Z (GMT). No. of bitstreams: 1 202859.pdf: 1428126 bytes, checksum: 3d3305744e59b748873306bacf4b4ec6 (MD5) / Este estudo, in vitro, teve como objetivo avaliar a efetividade de diferentes técnicas de remoção do excesso de cimento resinoso e sua relação na microinfiltração marginal de restaurações indiretas de resina composta. Em quarenta pré-molares hígidos foram confeccionadas duas cavidades ocluso-proximais e restauradas com inlays de resina composta. Durante a cimentação, as peças foram posicionadas no dente e pressionadas para que o cimento escoasse em toda margem para posterior remoçao com: fio dental (grupo 1); sonda exploradora (grupo 2), sistema EVA (grupo 3) e ultra-som (grupo 4). Concluiu-se que o fio dental é mais efetivo estatisticamente ao sistema EVA e ao ultra-som e que a efetividade da sonda exploradora na remoção do excesso de cimento resinoso é superior ao ultra-som, embora similar estatisticamente ao fio dental e ao sistema EVA.
56

Adesão à dentina

Lopes, Guilherme Carpena January 2003 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T20:55:16Z (GMT). No. of bitstreams: 0 / O objetivo foi verificar se há diferença na capacidade de união ao substrato dentinário envelhecido quando comparado com o jovem; e, se o aumento do tempo de condicionamento poderá resultar em uma maior resistência de adesão a este substrato envelhecido, sem prejudicar a união ao substrato jovem. Foram realizados testes de resistência de união, verificação da dureza dentinária e microscopia eletrônica de varredura da interface adesiva. A dentina envelhecida condicionada por 15s obteve resistência de união estatisticamente menor que todos os outros grupos. A dureza da dentina envelhecida foi maior do que a dentina jovem. O maior conteúdo mineral na dentina envelhecida dificulta a união, resultando em mais baixa m-TBS quando o condicionamento é feito por apenas 15s. Por outro lado, a duplicação do tempo de condicionamento resulta em mais adequada adesão à dentina envelhecida alcançando médias similares à dentina jovem.
57

Distribuição das tensões nos implantes osseointegrados em função da largura da mesa oclusal

Garanhani, Roberto Ramos January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T17:50:06Z (GMT). No. of bitstreams: 0 / A manutenção dos implantes osseointegrados e suas reabilitações protéticas é uma preocupação constante para a longevidade deste tipo de tratamento. Através deste estudo, revisou-se como as forças atuam sobre uma coroa protética unitária implanto-suportada, sua distribuição através do implante ao osso adjacente, diferenças em relação ao dente natural e os efeitos da diminuição da largura oclusal no controle das tensões na interface osso-implante. A literatura sugere que esta alteração no desenho oclusal diminui as tensões recebidas pelo implante e tecido ósseo adjacente.
58

Controle da alteração dimensional térmica em estruturas metálicas de próteses sobre implantes

Vasconcellos, Diego Klee de January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T17:55:52Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T18:53:57Z : No. of bitstreams: 1 188216.pdf: 1163111 bytes, checksum: bd764a2faf25b2edf3dd58d3ae4a14f2 (MD5) / Estudo in vitro que analisou a eficácia do condicionamento térmico de estruturas metálicas de próteses sobre implantes, previamente aos ciclos convencionais para cocção da cerâmica, no controle da alteração dimensional do metal.. Sete estruturas de Níquel-Cromo formaram o grupo controle, e foram tratados de maneira convencional. As outras estruturas, da mesma liga, constituíram o grupo teste, e foram submetidos a condicionamento térmico, logo após a fundição, ainda no interior do revestimento. Nos dois grupos, constatou-se a alteração dimensional estatisticamente semelhante após os ciclos térmicos para a cocção da cerâmica. Constatou-se a importância do aquecimento da liga previamente à prova em boca das estruturas metálicas, pois permite a avaliação de seu assentamento com a maior parte da alteração térmica dimensional já manifestada.
59

Determinação da resistência flexural de cimentos resinosos comerciais, com variação do sistema de ativação e tempo de armazenamento pós-ativação

Ferreira, Ana Paula Ribeiro Bonilauri 19 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-19T21:26:39Z (GMT). No. of bitstreams: 1 185447.pdf: 1185471 bytes, checksum: a9ac4351115382acbe72344a530a546a (MD5) / Este estudo investigou a resistência flexural de amostras confeccionadas com os cimentos resinosos duais Enforce, RelyX CRA e Variolink II submetidas à dupla ativação ou apenas à ativação química, aos trinta minutos e vinte e quatro horas após o início da polimerização. O cimento Enforce apresentou os valores mais altos de resistência flexural, independentemente do tipo de ativação e do tempo de armazenamento. No período de 30 minutos de armazenamento, não foram observadas significâncias estatísticas entre os materiais e a dupla ativação. Já, na polimerização química, o Enforce foi superior aos outros materiais testados neste mesmo tipo de polimerização. No período de 24 horas de armazenamento, não houve significâncias estatísticas na interação materiais x tipos de ativação.
60

Influência de diferentes tipos de pinos não metálicos na resistência à compressão de dentes anteriores restaurados com facetas de porcelana

Heck, Mary A. Pereira January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T02:34:46Z (GMT). No. of bitstreams: 1 186537.pdf: 1348916 bytes, checksum: a5bc7e70fbcb6c527be7c9c7cdbd2894 (MD5) / Foram utilizados 50 incisivos centrais superiores extraídos de humanos, escolhidos pela média do comprimento e pelo tamanho das cavidades de classe III para comparar a resistências à compressão de dentes hígidos com dentes tratados endodonticamente e restaurados conforme os grupos apresentados. Grupo I foram mantidos como controle (hígidos), os do grupo II, receberam terapia endodôntica e depois foram restaurados tanto no acesso endodôntico como nas cavidades de classe III com a resina Microhíbrida Filtek Z250, no grupo III os dentes sofreram todo o procedimento do grupo II e foram restaurados com facetas de IPS Empress 2, os dentes dos grupos IV e V, além de sofrerem estes procedimentos, foram restaurados respectivamente com o uso dos pinos pré-fabricados não metálicos intracanal dos sistemas Aestheti- Post (BISCO) e Fiberkor Post (JENERIC PENTRON). Depois destes procedimentos os dentes foram incluídos em resina acrílica autopolimerizável em tubos de PVC, mantendo-se uma distância de 2mm da junção amelo-cementária à resina com seus longos eixos paralelos em relação aos eixos dos tubos. Em seguida, forma levados a uma máquina universal de testes Instron 4444, onde, através de um dispositivo, forma montados numa angulação de 45° e receberam uma força de 0,5 mm/s que incidia na superfície palatina dos dentes a uma distância de 2mm da borda incisal. A média de resistência à fratura em Kgf dos grupos foi: grupo I - 115,75; grupo II - 85,31; grupo III - 88,06; grupo IV - 47,62 e grupo V - 98,34. Os resultados, que foram submetidos aos testes estatísticos Anova ( Análise de Variância) e comparações individuais pelo teste de Scheffeé, Mostraram diferença estatisticamente significante enter dos grupos _ - controle e grupo IV - dentes restaurados com pinos Aestheti-Post e facetas cerâmicas IPS Empress 2. Concluiu-se que as restaurações de dentes anteriores não vitais, com ou sem a associação de facetas cerâmicas em IPS Emperres 2 e com sistema de pinos não metálicas Fiberkor-Post apresentam resistência à fratura semelhante aos dentes hígidos.

Page generated in 0.0701 seconds