Spelling suggestions: "subject:"inventarios."" "subject:"comentarios.""
21 |
Interação dos cimentos do ProRoot MTA, MTA branco, MTA Bio e Portland branco com a dentinaCarmona, Jessie Fabiola Reyes January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-23T08:46:23Z (GMT). No. of bitstreams: 1
247966.pdf: 14616516 bytes, checksum: 4d006e9da5f998712de0ac8cb9f9f868 (MD5) / Os objetivos deste estudo foram analisar a quantidade e a composição química do precipitado formado pelos cimentos ProRoot MTA, MTA Branco, MTA BIO e Portland branco, após imersão em tampão fosfato salino (PBS); avaliar a interface cimento-dentina e, paralelamente, analisar o pH e a liberação de íons cálcio a partir dos cimentos empregados. As coroas de 28 dentes humanos foram removidas e o terço médio das raízes cortados transversalmente para a obtenção de discos radiculares com 2 mm de espessura. Em cada secção, o espaço do canal foi ampliado a fim de obter uma cavidade padronizada com 2 mm de diâmetro. As secções foram divididas aleatoriamente em 5 grupos, sendo as cavidades preenchidas com: ProRoot MTA (Grupo 1), MTA Branco (Grupo 2), MTA BIO (Grupo 3), CP1: Cimento de Portland branco com 20% de óxido de bismuto (Grupo 4), e CP2: Cimento de Portland branco com 20% de óxido de bismuto e 10% cloreto de cálcio (Grupo 5). Em seguida, as amostras foram colocadas em recipientes plásticos contendo 15 mL de PBS e levadas à estufa (37ºC) por um período de 2 meses. A solução tampão foi substituída a cada 5 dias. A cada substituição, os precipitados foram colhidos, lavados, dessecados e pesados. Aos 5, 15, 25 e 35 dias, a solução foi coletada para medição do pH e da concentração de íons cálcio. Ao final dos 2 meses, as amostras foram processadas para avaliação, em MEV, da interface cimento-dentina. Os dados foram analisados estatisticamente em um nível de significância de 5%. Em todas as amostras foi observada a formação de precipitados de apatita carbonatada e a presença de uma intercamada na interface cimento-dentina. A partir da intercamada, foram observados prolongamentos penetrando nos túbulos dentinários. O ProRoot MTA e o MTA BIO formaram maior quantidade de precipitados, geraram os valores de pH mais altos e a maior concentração de íons cálcio em todos os períodos de avaliação. O ProRoot MTA, o MTA Branco, o MTA BIO e o cimento Portland branco têm a capacidade de dissolver alguns de seus componentes e propiciar a precipitação de apatita carbonatada, promovendo a formação de uma intercamada com prolongamentos que penetram nos túbulos dentinários.
The aim of this study was to analyze the amount and the chemical composition of the precipitate formed by ProRoot MTA, White MTA, MTA BIO and white Portland cements, after immersion in phosphate buffered saline (PBS), to evaluate the cement-dentine interface and to analyze the pH and the calcium ions release. The crowns of 28 human teeth were removed and the middle third of the roots was sectioned transversally in order to obtain 2mm-thickness sections. In each section, the space of the canal was enlarged to obtain 2mm-diameter standardized cavities. The samples were randomly divided in 5 groups, and the cavities filled with: ProRoot MTA (Group 1), White MTA (Group 2), MTA BIO (Group 3), white Portland cement with 20% of bismuth oxide (CP1) (Group 4), and white Portland cement with 20% of bismuth oxide and 10% calcium chloride (CP2) (Group 5). The samples were immediately placed in plastic vials containing 15 mL of PBS for 2 months at 37ºC. The PBS solution was collected and replaced every 5 days. After each replacement, the precipitates were collected, washed, desiccated and weighed. Calcium ions release and pH of the collected solution were monitored at 5, 15, 25 e 35 days. The samples were processed for SEM observation. Data obtained were statistically analyzed with 5% level of significance. Precipitates of carbonated apatite were observed in all the samples, along with the presence of an interfacial layer between the cement and the dentinal wall. Tags reproducing demineralized tubular dentin were observed from the interfacial layer. ProRoot MTA and MTA BIO cements produced the overall highest amount of precipitates, reached higher pH values, and released more calcium ions at all time intervals. ProRoot MTA, White MTA, MTA BIO and white Portland cements have dissolved, releasing some of their major components, promoting the precipitation of carbonated apatite and the formation of an interfacial layer with tags.
|
22 |
A influência de diferentes técnicas e sistemas de cimentação na resistência de união de uma cerâmica reforçada por leucita à dentinaRodrigues, Eduardo Roberty Coutinho January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-24T05:42:00Z (GMT). No. of bitstreams: 1
264430.pdf: 4411827 bytes, checksum: 5c903963b4c58e655ba474c113f6e1cf (MD5) / O objetivo deste estudo in vitro foi testar a hipótese de que diferentes técnicas e sistemas de cimentação influenciam na resistência de união de uma cerâmica reforçada por leucita à dentina, através do teste de microtração. Vinte e sete terceiros molares humanos tiveram a superfície dentinária média exposta de forma plana, através de uma secção transversal realizada com um disco diamantado. O substrato restaurador foi uma cerâmica reforçada por leucita (ProCad) com 3mm de espessura. Três técnicas de cimentação foram aplicadas: C, onde o sistema adesivo não foi fotoativado antes do assentamento da cerâmica; P, na qual o sistema adesivo foi fotoativado antes do assentamento da cerâmica; e S, onde foi realizado o chamado selamento dentinário imediato, no qual o adesivo é aplicado antes da temporização, e novamente na cimentação. Cada técnica foi realizada com 3 sistemas de cimentação: OP, utilizando o adesivo Optibond FL e o cimento resinoso dual Nexus 2; SB, em que foram utilizados o adesivo Adper Single Bond 2 e o cimento resinoso dual Rely X ARC; e CF, utilizando o adesivo Clearfil SE e o cimento resinoso dual Panavia F. Após uma semana de temporização, os procedimentos de cimentação foram realizados e os dentes cimentados foram armazenados em água destilada por 24h a 37ºC. Os elementos dentais foram preparados para serem submetidos ao teste de microtração, sendo realizados cortes nos eixos "X" e "Y" para a obtenção de filetes retangulares com área de secção transversal de 0,64mm2. Os filetes foram tracionados em uma máquina de ensaios universal (Instron). Os padrões de fratura de todos os filetes foram analisados no MEV. O teste estatístico Anova dois critérios seguido do teste de comparações múltiplas de Tukey indicou que a técnica (p < 0,01) e o sistema de cimentação (p < 0,01) influenciam na resistência de união da cerâmica à dentina. Quase que a totalidade das fraturas aconteceu dentro da interface adesiva. De acordo com os resultados pode-se concluir que a hipótese foi totalmente aceita, e que a técnica e o sistema de cimentação devem ser analisados em conjunto. A fotopolimerização do adesivo, em conjunto com o cimento resinoso, após o assentamento da cerâmica, é recomendada para a obtenção de uma resistência de união mais alta da cerâmica à dentina.
The aim of this in vitro study was to test the following hypothesis: different cementation techniques and systems affect microtensile bond strength between dentin and a leucite reinforced ceramic. Twenty-seven human third molars were prepared for bonding by removing the occlusal surface. A medium depth flat dentin were exposed after performing a transversal section. The restorative substrate was a 3mm thick leucite reinforced ceramic (Pro Cad). Three cementation techniques were applied: C - adhesive system was not photopolymerized before ceramic setting; P - adhesive system was photopolymerized before ceramic setting and S - immediate dentin sealing was performed, which the adhesive system is applied before temporization and at cementation. Each technique was performed using three cementation systems: OP - Optibond FL adhesive system and Nexus 2 dual resin cement; SB - Adper Single Bond 2 adhesive system and Rely X ARC dual resin cement and CF - Clearfill SE adhesive system and Panavia F dual resin cement. After one-week temporization, the cementation procedures were performed. The cemented teeth were stored in distilled water for 24 hours at 37 degrees C. For microtensile bond test, the dental elements were longitudinally sectioned in both "X" and "Y" directions in order to obtain rectangular sticks with an approximately 0.64mm2 cross-sectional área. The sticks were fractured on a universal tests machine (Instron). Fracture patterns of all sticks were analyzed by scanning electronic microscopy (SEM). Statistical test Anova two-way followed by Tukey multiple comparisons test revealed that the cementation technique and system affect microtensile bond strength between dentin and ceramic. Almost all fractures occurred at the adhesive interface. According to the results, it can be concluded that the hypothesis was totally accepted. Almost the entire fractures occured within the adhesive interface. It was concluded that the cementation technique and system must be analyzed together. Co-polimerization between the bonding resin and the luting cement, after the seatting of the restauration is advised in order to achieve higher bond strength between ceramic and dentin.
|
23 |
Avaliação da resistência flexural de um cimento resinoso dual submetido a diferentes simulações clínicasSilveira, Márcia Regina da January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-16T02:16:48Z (GMT). No. of bitstreams: 1
224733.pdf: 2686794 bytes, checksum: fcf185a4eb6457565a2c8ace1b8c9b8b (MD5) / O objetivo desta pesquisa foi avaliar a resistência flexural do cimento resinoso dual Rely-X CRA (3M ESPE), submetido a situações clínicas simuladas, após os tempos de armazenagem de 15 minutos e 24 horas (n=12). As amostras foram confeccionadas baseadas na ISO padrão 4049 nas seguintes simulações: fotoativação nas margens da restauração, fotoativação através de discos de porcelana (Empress 2, cor A2) de 2, 3 e 4 mm de espessura e cura somente química. Obstáculos cerâmicos de 3 e 4 mm e a ausência de luz reduziram significativamente a resistência flexural após 15 minutos de armazenagem. O obstáculo e o tipo de ativação não influenciaram a resistência flexural das amostras testadas após 24 horas. De maneira geral, o aumento do tempo de armazenagem contribuiu para o aumento dos valores de resistência flexural.
|
24 |
Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posterioresLima, Luana Machado de January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-06-25T20:55:23Z (GMT). No. of bitstreams: 1
308829.pdf: 770581 bytes, checksum: 8278409b6c8fa7aeb27cac498c1d4855 (MD5) / A presente tese teve como objetivo avaliar se o preaquecimento do sistema adesivo e da resina composta foi capaz de promover melhor performance clínica às restaurações em dentes posteriores. Após aprovação do comitê de ética, participaram desta pesquisa 70 pacientes com necessidades de restaurações: oclusal, ocluso-distal ou mesio-oclusal. Utilizou-se do preaquecimento de dois sistemas adesivos [Single Bond 2 (3M ESPE) e P90 Bond (3M ESPE)] e duas resinas compostas: nanoparticulada matriz orgânica metacrilato Filtek#Z350 (3M ESPE) e micro-híbrida matriz orgânica silorano Filtek#P90 (3M ESPE). Esses materiais foram avaliados por um período de 18 meses. Assim, as cavidades pareadas, no mesmo paciente (n=35), formaram os grupos: 1A-Single Bond 2 (3M ESPE), Filtek# Z350 (3M ESPE), sem preaquecimento, (temperatura ambiente, ±25 °C); 1B- mesmos materiais restauradores com preaquecimento (54 °C); 2A- P90 Primer, P90 Bond com Filtek P90 (3M ESPE) sem preaquecimento, (temperatura ambiente, ±25 °C); 2B - mesmos materiais restauradores com preaquecimento (54 °C). Um aparelho de preaquecimento do adesivo e da resina composta, o (Calset#, AdDent Inc., Danbury, CT, EUA), serviu para o propósito. A sensibilidade pós-operatória foi avaliada pela escala de VAS. Após 24 h, as restaurações foram acabadas e polidas. Dois examinadores independentes as avaliaram, conforme método modificado USPHS em intervalos de: 7 dias após o polimento final, 6 meses, 12 meses e 18 meses. Realizaram-se radiografias periapicais e interproximais durante as reavaliações. Foi utilizado o modelo estatístico de regressão logística simples "Razão de Verossimilhança" com nível de significância de 5 % (p<0,05). Em 7 dias, 6 meses, 12 meses e 18 meses após a confecção inicial das restaurações, todas as 140 restaurações (100%) foram avaliadas. Em nenhuma reavaliação houve diferenças significativas nos critérios examinados. Nem a resina composta nem o preaquecimento influenciaram significativamente o desempenho clínico. Em todos os períodos de avaliação, as restaurações se mostraram aceitáveis em todos os quatro grupos para todos os critérios (entre 91,4% e 100% de escores ALFA). Não houve relato de dor. Não houve recidiva de cárie e nem diferenças na adaptação marginal dos materiais ao exame radiográfico. O preaquecimento dos materiais restauradores (sistema adesivo e resina composta) não influenciou a performance clínica. Ao longo dos 18 meses, os materiais e técnicas empregados apresentaram promissores resultados. / This thesis aimed to evaluate whether the preheating of the adhesive systems and composite resin was able to promote best clinical performance of restorations in posterior teeth. After approval by the Ethics Committee, 70 patients who needed restorations in occlusal, occlusal-distal or mesio-occlusal participated in this research. The preheating of two adhesive systems [Single Bond 2 (3M ESPE) and P90 Bond (3M ESPE)] as well as two composite resins: metacrilato organic matrix nanoparticulate Filtek#Z350 (3M ESPE) and the silorano organic matrix microhybrid Filtek#P90 (3M ESPE). These materials were evaluated for a period of 18 months. Hereafter are the groups with paired cavities in the same patient (n=35): 1A- Single Bond 2 (3M ESPE), Filtek# Z350 (3M ESPE) without preheating (room temperature, ±25 °C); 1B- same restorative materials with preheating (54 °C); 2A- P90 Primer, P90 Bond (3M ESPE) with Filtek P90 (3M ESPE) without preheating (room temperature ±25 °C); 2B- the same restorative materials with preheating (54 °C). An apparatus for preheating of the adhesive and the composite resin, (Calset#, AdDent Inc., Danbury, CT, EUA) was used for the purpose of this thesis. The Post-operative sensitivity was evaluated using the VAS scale. After 24 h, the restorations were finished and polished. Two independent observers rated the restorations according to the USPHS modified method in intervals of: 7 days, 6 months, 12 months and 18 months after the final polishing. Periapical and bitewing radiographs were used during reassessments. The statistic model of simple logistic regression "Likelihood Ratio" with a significance level of 5 % (p<0,05) has been used in this thesis. All 140 restorations (100%) were evaluated in 7 days, 6 months, 12 months and 18 months after the initial production of the restorations. It has been found no significant difference in the examined criteria during the evaluations. Neither the restorative materials nor the preheating significantly influenced clinical performance. In all evaluation periods, the restorations proved to be acceptable in the four groups for all criteria (between the ALFA 91,4% to 100% of scores ALFA). There were no reports of pain. There was no recurrence of caries and no differences in marginal adaptation of materials to the radiographic examination. The preheating of restorative materials (adhesive system and composite resin) did not influence the clinical performance. Over the 18 months, the materials and techniques employed showed had promising results.
|
25 |
Avaliação in vitro da resistência de união de sistemas adesivos à dentina e ao esmalte de dentes decíduosMiranda, Carla January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-15T22:41:41Z (GMT). No. of bitstreams: 1
224768.pdf: 4074084 bytes, checksum: 3cf4ae3db421cf659ba7608e8614c12e (MD5) / Este estudo procurou avaliar a resistência de união ao cisalhamento (RUC) de quatro sistemas adesivos à dentina e ao esmalte decíduos, e verificar, após teste de RUC, o tipo de falha na interface adesiva. Sessenta molares decíduos hígidos extraídos tiveram as coroas cortadas no sentido mésio-distal. Os espécimes foram divididos em dois grupos, dentina e esmalte, e subdivididos em quatro subgrupos, de acordo com o sistema adesivo (n=15): Scotchbond Multi-Purpose (SMP), Single Bond (SB), Clearfil SE Bond (CSB) e Adper Prompt L-Pop (APL). Os valores obtidos foram submetidos à ANOVA e Teste de Tukey (p< 0,05). O tipo de fratura predominante foi do tipo coesiva no adesivo. Em esmalte os sistemas adesivos apresentaram RUC estatisticamente similares entre si. Em dentina a RUC do sistema adesivo Adper Prompt L-Pop foi inferior em relação aos demais sistemas adesivos, que foram similares entre si.
|
26 |
Análise da interface e resistência de união de cimentos endodônticos à dentina radicular após imersão em solução tampão fosfato salinoTedesco, Maybell January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-12-05T21:25:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2012
|
27 |
Avaliação laboratorial da resistência ao cisalhamento de discos de porcelana e de um polímero de vidro cimentados à dentina bovina com o emprego de cimentos adesivosHuhtala, Maria Filomena Rocha Lima [UNESP] 14 June 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0
Previous issue date: 1999-06-14Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1
000125687.pdf: 6035778 bytes, checksum: 4533912c616dc12e7fcecd4968df99bd (MD5) / O objetivo deste estudo foi comparar a efetividade de três cimentos: Cimento Resinoso (3M), Variolink (Vivadent) e Fuji Plus (GC Coorp.); na adesão de discos de porcelana (Fortune,Williams) e de um polímero de vidro (Artglass, Kulzer), à dentina bovina. A superfície vestibular de 120 incisivos bovinos, previamente incluídos em resina acrílica, foi planificada com lixa d'água (granulação 80), e a dentina exposta e regularizada, com lixas de papel de granulação decrescente (240,400 e 600), sob-constante refrigeração de água. Sobre estas superfícies foram cimentados discos, de 5mm de diâmetro x 3mm de altura, de porcelana ou do polímero de vidro, que tinham recebido em sua base um alívio de 40µm, para conter o cimento e padronizar sua espessura. A cimentação foi estática, realizada com o auxílio de um delineador adaptado, e os cimentos empregados de acordo com as indicações dos fabricantes. Os espécimens foram divididos aleatoriamente em grupos de dez. Cada dois grupos receberam o mesmo material e cimento; sendo que destes, um foi testado após 24 h e o outro após seis meses, quanto à resistência ao cisalhamento, em máquina de ensaios universal Instron. Os valores de resistência adesiva obtidos, receberam os testes estatístico ANOVA e de Tukey, 0,05%. As superfícies fraturadas foram observadas em estereomicroscópio (Karl Zeiss). Os resultados demonstraram que o Cimento Resinoso (3M) foi o que apresentou os maiores valores médios de resistência adesiva (14,16MPa); que a adesão da porcelana foi superior; e, que o tempo influenciou, apresentando a avaliação após seis meses, resultados maiores que após 24h. As fraturas foram predominantemente mistas, com algumas fraturas coesivas do cimento e dos materiais também. Pode ser concluído que o Cimento Resinoso e os procedimentos empregados ofereceram uma razoável resistência ao cisalhamento, tanto à porcelana , ... / The aim of this study was to investigate the effectiveness of three luting agents : Resin Cement (3M), Variolink (Vivadent) e Fuji Plus (GC Coorp.); in bonding porcelain (Fortune, Williams) and glass polymer (Artglass, Kulzer) discs. To bovine dentin. The facial surfaces of 120 bovine incisors, previously mounted in self-cured resin, were ground flat on wet 80-grit SiC paper. Dentin surfaces exposed had their final finish accomplished by grinding on wet 240, 400 and 600-grit SiC paper. The specimens were randomly assigned to test groups of ten samples. Onto the pretreated dentin surfaces, the discs (5mm diameter,3mm height) were cemented Jhey were seated to a standardized luting thickness of 40µ. Each two groups were cemented with the same luting agent, and one of them shear tested after 24 h and the other after 180 days in an Instron machine. The bond strength data obtained were analysed by ANO VA and the Tukey test, 5%. The mode of failure was classified. The shear test results indicated significant differences among the luting agents: Variolink II (6, 02MPa), Fuji Plus (1 1,20MPa) and with the highest shear bond stregth accomplished when the 3M Resin Cement was the luting agent (14,16MPa). Higher values were also obtained with the porcelain discs and after the 180 days storage period. Mode of failure varied among the groups, with predominance of mixed fractures at the tooth/cement interface, and with a few cohesive porcelain and glass polymer fractures. It can be concluded that the Resin Cement (3M) and the procedure used offer reasonable strength on the porcelain and dentin site
|
28 |
Continuação dos estudos sobre alterações dimensionais, de resistência à tração e de resistência ao dobramento, em corpos de gesso, consequente à sua fratura, seguida de colagem /Springmann, Werner January 1975 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-15T19:36:44Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T13:06:37Z : No. of bitstreams: 1
141692.pdf: 4792738 bytes, checksum: af8908cc1e529c5c629472ae7ab3d4b9 (MD5)
|
29 |
Efeito de agentes contaminantes durante os procedimentos adesivos na resistência de união à dentinaSousa, Cleo Nunes de 24 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2009 / Made available in DSpace on 2012-10-24T21:38:46Z (GMT). No. of bitstreams: 1
271865.pdf: 726369 bytes, checksum: f7b352453fa6e92e33fb1a26ad2560cb (MD5) / O objetivo desta tese foi avaliar a resistência de união de um sistema adesivo de frasco único ao substrato dentinário contaminado com saliva e óleo lubrificante após o condicionamento ácido. Para isso, 10 molares humanos foram cortados transversalmente expondo dentina superficial oclusal, polidos até lixa 600 e divididos em 5 grupos. No grupo 1 (G1), o sistema adesivo frasco único (Prime&Bond NT, Dentsply) foi aplicado conforme instruções do fabricante. No grupo 2 (G2), a superfície dentinária foi contaminada com saliva fresca após o condicionamento com ácido fosfórico e antes da aplicação do sistema adesivo. No grupo 3 (G3), procedeu-se de forma similar ao G2, entretanto a superfície contaminada foi seca com jatos de ar durante 5s para remoção da contaminação salivar. No grupo 4 (G4), a superfície dentinária foi contaminada com óleo lubrificante para peça-reta após o condicionamento com ácido fosfórico e antes da aplicação do sistema adesivo. No grupo 5 (G5), procedeu-se de forma similar ao G3, entretanto a superfície contaminada foi seca com jatos de ar durante 5s para remoção do óleo lubrificante. Em todos os grupos, a resina composta (TPH Spectrum, Dentsply) foi inserida em 4 incrementos de 1mm e fotopolimerizada. Depois de 24h em água, os espécimes foram cortados em duas direções perpendiculares com um disco diamantado em baixa velocidade, para obterem-se os filetes com uma secção de aproximadamente 0,07mm2. Estes foram colados em um dispositivo montado em uma máquina Instron, e a resistência de união por microtração (MTBS) foi medida. Os dados foram analisados com ANOVA e Scheffé (p < 0,0001). As médias (±DP) de MTBS foram: G1=56,2 (±13,6)A, G2=16,0 (±10,4)B, G3=33,2 (±18,7)C, G4=38,2 (±17,8) e G5=11,3 (±7,3). Conclui-se que tanto a contaminação pelo óleo lubrificante como a contaminação pela saliva exercem um efeito negativo na resistência de união mesmo quando forem removidos com jato de ar. Para o óleo lubrificante foi observada também a diminuição dos valores obtidos quando da tentativa de remoção do contaminante.
|
30 |
Influência da contaminação pela fumaça do cigarro na força de união entre dentina e compósitoSilva, Júnio S. Almeida e January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-24T01:59:35Z (GMT). No. of bitstreams: 1
200873.pdf: 16409018 bytes, checksum: 14c4832cec80b7845b877f234cde409d (MD5) / O objetivo deste estudo in vitro foi avaliar a força de união entre dentina contaminada pela fumaça do cigarro e resina composta. A metodologia utilizada foi o teste de microtração. Foram utilizados dez terceiros molares humanos, dos quais seis foram destinados ao teste de microtração, e os quatros dentes restantes tiveram suas superfícies dentinárias analisados com o MEV. Mediante a realização de cortes seqüenciais, cada dente teve sua porção radicular eliminada e a parte coronal dividida em duas, no sentido mésio-distal. Assim, foram obtidas vinte metades das dez partes coronais. O substrato para adesão foi dentina profunda através de acesso apical. Para a confecção dos corpos-de-prova, cada metade dental foi incluída em resina epóxi através de uma matriz metálica bipartida. Os vinte corpos-de-prova foram distribuídos em dois grupos experimentais (FC e SFC), de maneira que cada dente foi controle de si mesmo ao destinar uma metade a cada grupo. Os corpos-de-prova pertencentes ao grupo FC sofreram escovação simulada diária por meio de um dispositivo desenvolvido para esta pesquisa e exposição à fumaça do cigarro em uma câmara simuladora do ato de fumar por um regime de trinta cigarros por dia durante dezessete dias. Os corpos-de-prova pertencentes ao grupo SFC somente sofreram escovação simulada diária. A análise no microscópio eletrônico de varredura (MEV) revelou a presença de contaminantes nas superfícies dentinárias dos corpos-de-prova do grupo FC antes e após o condicionamento ácido. Para o teste de microtração, foi de forma incremental confeccionada uma base de resina composta Z250 (3M ESPE) de seis milímetros utilizando-se o sistema adesivo Scotchbond Multipurpose Plus (3M ESPE) na superfície dentinária de cada corpo-de-prova. Os corpos-de-prova foram mantidos em água destilada a 37 ºC por 24 horas e seccionados longitudinalmente nos eixos x e y para a obtenção de filetes retangulares com área de secção transversal de aproximadamente 0.45 mm2. O filetes foram tracionados à velocidade de cruzeta de 0,5 mm/min até o registro da carga necessária para ruptura. Os padrões de fratura foram analisados em um microscópio estereoscópio (25 x). A análise estatística (teste t) demonstrou a existência de diferença significante entre as médias dos grupos testados, com o valor de p = 0.001. O grupo FC (49.58 MPa) apresentou inferior resistência de união quando comparado ao grupo SFC (58.48 MPa). De acordo com os resultados, conclui-se que a contaminação pela fumaça do cigarro diminui a resistência de união entre dentina e resina composta.
|
Page generated in 0.0906 seconds