• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Síntese do 2,3-epitiopropil metacrilato e seu uso no desenvolvimento de um adesivo odontológico / 2,3-epithiopropyl methacrylate synthesis and application in a dental adhesive

Ogliari, Fabrício Aulo 10 July 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:18Z (GMT). No. of bitstreams: 1 Dissertacao_ Fabricio_Aulo_Ogliari.pdf: 587095 bytes, checksum: 8bb56a09354ea01200df793cf0e60ef5 (MD5) Previous issue date: 2009-07-10 / The aim of this study was to synthesize and to investigate the influence of the 2,3-epithiopropyl methacrylate (ETMA) in a dental adhesive. Synthesis of the ETMA was performed using glycidyl methacrylate as starting reagent, catalyzed by cerium ammonium nitrate in presence of NH4SCN. After purification, ETMA was characterized by 1H NMR and FTIR spectroscopy. ETMA monomer was used as an additive agent in a commercial available dental adhesive (Scotchbond Multipurpose, 3M ESPE) at three different concentrations (0.1, 1 and 10 wt %). Adhesive without ETMA was used as control group. Degree of conversion of the polymerized adhesives was accomplished by FTIR analysis. Blend copolymerization was investigated by 1H NMR spectroscopy analysis. To investigate immediate and long-term properties of the adhesives, microtensile bond strength to human dentin and SEM fractographic analysis were performed. ETMA was synthesized through the conversion of GMA with NH4SCN and high yield was obtained (90%). One-step s synthetic route and a simple manner of purification were described. ETMA presence didn t affect the degree of conversion of the adhesive resins. The monomer that composed the adhesive resins presented copolymerization among them, not presenting ETMA release in 0.1 and 1% groups. Experimental adhesives had statistically higher microtensile bond strength values than the no ETMA adhesive (p<0.05), independently of the water storage. All groups were stable over time / O objetivo deste estudo foi sintetizar e avaliar a influência do 2,3-epitiopropil metacrilato (ETMA) utilizado como monômero funcionalizado sobre a resistência de união imediata e longitudinal de um adesivo comercial. O ETMA foi sintetizado através da transformação do glicidil metacrilato na presença de tiocianato de amônio catalisado por nitrato de cérico de amônio. O produto obtido, após destilação, foi confirmado e caracterizado por ressonância magnética nuclear de prótons e por espectroscopia no infravermelho. ETMA foi utilizado como aditivo na quantidade de 0,1, 1 e 10% em massa a um adesivo comercial (Scotchbond Multiuso - SBMU, 3MESPE). Como controle SBMU sem ETMA foi testado. Foi avaliada a capacidade de copolimerização do ETMA com os outros monômeros do adesivo comercial assim como a sua influência no grau de conversão e na resistência de união à microtração em dentina. A resistência de união a microtração em dentina foi avaliada após 24h, 6 meses e 12 meses de armazenagem em água destilada. As amostras fraturadas do ensaio de microtração foram avaliadas por microscopia eletrônica de varredura e microscopia ótica para a análise do modo de fratura. Foi possível a síntese do ETMA através da conversão de GMA utilizando NH4SCN como reagente. Um rendimento global de 90% foi atingido utilizando-se um método simples de purificação. A adição de ETMA não influenciou os valores de grau de conversão e estes sistemas monoméricos demonstraram capacidade de copolimerização ente si, não apresentando traços de liberação de ETMA nos grupos de 0,1 e 1%. Os adesivos contendo ETMA apresentaram valores de resistência de união significativamente maiores que o grupo controle sem ETMA (p<0.05). Os valores de resistência de união do grupo controle e dos grupos experimentais permaneceram estáveis mesmo após 12 meses de armazenagem, sendo que os grupos experimentais apresentaram valores mais elevados de resistência de união em comparação ao controle independentemente do período de avaliação
222

LONGEVIDADE DA UNIÃO DE SISTEMAS ADESIVOS UNIVERSAIS EM DENTINA HÍGIDA E AFETADA / BONDING LONGEVITY OF UNIVERSAL ADHESIVE SYSTEMS ON SOUND AND CARIES-AFFECTED DENTIN

Follak, Andressa Cargnelutti 29 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A new generation of adhesive systems are currently available on market. They were reported on the literature as universal adhesives or multimode adhesives . These adhesives are versatile, as they can be use in either etch-and-rinse or self-etch strategy. However, only a few data is available about long-term bonding behavior of universal adhesive systems. Then, the aim of this study is to evaluate immediate and six months bond strength of different universal adhesive systems on sound and caries-affected dentin, either on etch-and-rinse or self-etch strategies. The adhesive systems tested were: Scotchbond Universal (3M ESPE), All-Bond Universal (Bisco), Prime & Bond Elect (Denstply Caulk), Adper Single Bond 2 (3M ESPE) and Clearfil SE Bond (Kuraray Noritake Dental). All adhesive systems were applied under manufacturer s instructions and a composite block was build up on dentin surfaces. Caries-affected dentin was artificially induced by pH-cycling (8h immersed on demineralizing solution and 16h on remineralizing solution, for 14 days). Stick shaped specimens (0,8 mm²) were obtained to be submitted to microtensile test at immediate time or after 6 months of storage. Bond strength data (MPa) were analyzed by three-way repeated measures ANOVA and post-hoc Tukey test (α= 5%). Analysis were performed for each substrate separately. On sound dentin, the etching strategy did not influence bond strength of universal adhesives and no significant statistical differences were found for bond strength values after 6 months of water storage. On caries-affected dentin, adhesive systems also showed similar results regardless etching strategies. However, significant reduction in bond strength values was found after six months. The etching strategy did not influence bond strength performance of universal adhesives on dentin substrate, although the long-term bond strength is decreased on caries-affected dentin. / Recentemente foram introduzidos no mercado uma nova geração de adesivos, reportados pela literatura como adesivos universais ou multi-modo . Esses adesivos são materiais versáteis, podendo ser utilizados tanto na técnica autocondicionante como na técnica com condicionamento ácido prévio. No entanto, pouco sabe-se ainda sobre o comportamento desses adesivos universais em relação à longevidade da adesão. Então, o objetivo deste estudo foi avaliar a resistência de união imediata e após 6 meses de diferentes adesivos universais em dentina hígida e afetada, usando as estratégias de condicionamento ácido prévio e autocondicionante. Os sistemas adesivos testados foram: Scotchbond Universal (3M ESPE), All-Bond Universal (Bisco), Prime & Bond Elect (Denstply Caulk), Adper Single Bond 2 (3M ESPE) e Clearfil SE Bond (Kuraray Noritake Dental). Todos os adesivos foram aplicados seguindo as recomendações dos fabricantes e um bloco de resina composta foi construído sobre a dentina. A dentina afetada foi obtida artificialmente através de ciclagem de pH (8 horas em solução desmineralizante e 16 horas em solução remineralizante, por 14 dias). Espécimes em forma de palitos foram obtidos (0,8 mm²) para serem submetidos ao teste de microtração imediatamente ou após 6 meses de armazenamento. Os dados obtidos em MPa foram analisados por análise de variância de 3 fatores e teste de contraste de Tukey (α= 5%). A análise foi realizada separadamente para cada substrato. Em dentina hígida, a estratégia de condicionamento não teve influência na resistência de união dos adesivos universais e não houve diferença estatisticamente significante entre a resistência de união imediata e após 6 meses. Em dentina afetada, os sistemas adesivos apresentaram resultados similares, independente da estratégia de condicionamento. No entanto, houve uma significativa redução na resistência de união após 6 meses. Assim, a estratégia de condicionamento não influencia a resistência de união dos adesivos universais em dentina, porém a resistência de união a longo prazo é reduzida em dentina afetada.
223

Evaluation of bond strenght, polymerization stress, adaptation in cavity class II and other properties of restorative systems = Avaliação da resistência de união, contração de polimerização, adaptação em cavidade classe II e de outras propriedades de sistemas restauradores / Avaliação da resistência de união, contração de polimerização, adaptação em cavidade classe II e de outras propriedades de sistemas restauradores

Di Francescantonio, Marina, 1983- 02 January 2013 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T02:40:13Z (GMT). No. of bitstreams: 1 DiFrancescantonio_Marina_D.pdf: 9411648 bytes, checksum: 630d235ee327706c683e7ef6351e4328 (MD5) Previous issue date: 2013 / Resumo: Os objetivos deste estudo foram: 1) caracterizar os elementos químicos e morfologia das partículas de carga de compósitos convencionais e de baixa contração; 2) avaliar a rugosidade superficial (RS) e 3) a sorção de água (SA) e solubilidade (SO) após acabamento/polimento, 24h e após 1 ano de armazenamento de água; 4) tensão de polimerização (TP) dos compósitos; 5) avaliar a adaptação interna (AI) em cavidades Classe II utilizando técnica restauradora incremental e bloco único 24h e um ano de armazenamento em água e 6) a resistência de união (RU) de sistemas restauradores baseados em metacrilatos e silorano após 24 h e após um ano de armazenamento. Quatro resinas compostas foram avaliadas: duas de baixa contração (Filtek Silorane e Aelite LS) e duas convencionais (Heliomolar e Tetric N-Ceram) Para a RU e análise FF, adesivos do mesmo fabricante foram utilizados: Excite para Tetric NCeram e Heliomolar; One-Step Plus para Aelite LS e Silorane System Adhesive para Filtek Silorane. Para caracterizar as partículas de carga, uma porção de cada material (n=5) foi imersa em solventes orgânicos e observada por MEV e EDS. Para avaliar a RS, SR e SO (n=10), os sistemas de acabamento e polimento foram usados seguindo as instruções do fabricante. As superfícies polidas foram analisadas utilizando um perfilometro, determinando a RS. Para a SR e SO , as amostras foram armazenadas e a massa de cada amostra foi medida. Os espécimes foram dessecados novamente e a massa da amostra foi determinada. A SR e SO foram calculadas a partir dessas medições. Os dados foram analisados por ANOVA e teste de Tukey (p=0,05).TP (n=5) foi determinada através da inserção dos compósitos entre as hastes de polimetilmetacrilato. Os dados analisados por ANOVA e teste de Tukey (p=0,05).Paraa análise de AI (n=4), trinta e dois molares receberam cavidades Classe II e foram restaurados com a técnica incremental ou bloco único. Depois de seccionados perpendicularmente, impressões foram realizadas e réplicas em resina epóxi foram obtidas da superfície interna das restaurações para a análise da formação de fendas através de MEV e os dados foram analisados por ANOVA e teste de Tukey (p=0,05). Para RU (n=8),superfícies de dentina de terceiros molares foram restauradas, seccionadas e armazenadas em água destilada antes do teste de RU. Os dados foram analisados por ANOVA e teste de Tukey (p=0,05). Todas as resinas compostas continham silício, e outros componentes variados. As resinas apresentaram morfologia e tamanhos diferentes de partículas de carga. Filtek Silorane apresentou as menores médias de RS, SR e SO. O armazenamento em água por um ano aumentou a SR para todas as resinas compostas testadas. Filtek Silorane apresentou TP semelhantes aos materiais à base de metacrilato, a menor AI e as maiores médias de RU após um ano de armazenamento. A resina composta de baixa contração Filtek Silorane se mostrou como alternativa aos materiais de formulação convencional, para restauração de dentes posteriores, uma vez que em vários testes realizados ela obteve os melhores resultados / Abstract: The aim of this study were: 1) to characterize the chemical elements and the morphology of filler particles in conventional and low-shrinkage composite resins; 2) to evaluate the surface roughness (SR) and 3) the water sorption (WS) and solubility (SO) after finishing/polishing 24h and after 1 year of water storage; 4) polymerization stress (PS) of the composites; 5) To evaluate the internal adaptation (IA) on Class II cavity walls using incremental and bulk filling restorative technique 24h and one year of water storage and 6) the bond strength (BS) of silorane- and methacrylate-based restorative systems after 24h and one year of water storage to dentin. Four composites were evaluated: two low shrinkage (Filtek Silorane and Aelite LS) and two conventional composites (Heliomolar and Tetric NCeram). For the BS and IA analysis, the adhesives from the same manufacturer were used: Excite for Tetric N-Ceram and Heliomolar; One-Step Plus for Aelite LS and Silorane System Adhesive for Filtek Silorane. To identify the inorganic components and to evaluate the filler particles characteristics, the materials (n=5) were immersed in organic solvents to eliminate the organic phase and observed by SEM and EDX. For the SR evaluation, WS and SO (n=10) their respective finishing and polishing systems were used following the manufacturer instructions. Polished surfaces were analyzed using a profilometer. For the WS and SO, the discs were stored in desiccators until constant mass. Specimens were stored in water and the mass of each specimen was measured. The specimens were dried again and the mass was determined. The WS and SO were calculated from these measurements. Data analyzed by ANOVA and Tukey's test (p=0.05). PS (n=5) was determined by the insertion of the composite between rods of polymethyl methacrylate. Data analyzed by ANOVA and Tukey's test (p=0.05).For IA analysis (n=4), thirty-two molars received Class II cavities and were restoring according to incremental or bulk filling technique. After sectioned perpendicularly, impression were taken and epoxy resin replicas were obtained of the internal surface of restorations to analysis gap formation using scanning electron microscopy (SEM) and the data was analyze by ANOVA and Tukey's test (p=0.05). For BS test (n=8), dentin surfaces of third molars were bonded, sectioned and stored before BS test. Data was analyzed by ANOVA and Tukey's test (p=0.05). All composite resins contained silicon, but the other components varied. The resins showed different filler particle sizes and morphologies. Filtek Silorane showed the lowest SR, WS and SO means. Water storage for one year increased the WS means for all composite resins tested. Filtek Silorane showed the highest means of bond strength after one year of storage, the lowest formation of gaps and PS similarly methacrylates based materials. The composite resin of low shrinkage Filtek Silorane showed as an alternative to conventional composites for restoration of posterior teeth, since in many tests has obtained the best results / Doutorado / Dentística / Doutora em Clínica Odontológica
224

Evaluation of different adhesive systems on the bond strength of a silorane based resin after 24 hours or 6 months of storage = Avaliação de diferentes sistemas adesivos na resistência de união de um compósito a base de silorano, após 24 horas ou 6 meses de armazenamento / Avaliação de diferentes sistemas adesivos na resistência de união de um compósito a base de silorano, após 24 horas ou 6 meses de armazenamento

Soares, Giulliana Panfiglio, 1981- 22 August 2018 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T02:49:00Z (GMT). No. of bitstreams: 1 Soares_GiullianaPanfiglio_D.pdf: 64597032 bytes, checksum: e11e3cff0a47e90986ae7f73605e5aa2 (MD5) Previous issue date: 2013 / Resumo: A manutenção da integridade entre a interface dente e restauração é importante para o sucesso clínico de restaurações adesivas, influenciando significativamente na longevidade das mesmas. Assim, o objetivo deste trabalho in vitro, foi avaliar o efeito de diferentes sistemas adesivos na resistência de união à dentina e ao esmalte de uma resina composta a base de silorano, após 24 horas e 6 meses de armazenamento. Para este estudo, setenta terceiros molares humanos hígidos, recém-extraídos e não restaurados, foram usados em um dos dois testes de resistência de união. Para a resistência à microtração à dentina, vinte e oito terceiros molares humanos, sem raízes, tiveram a superfície oclusal planificada a fim de expor a dentina superficial. Os dentes foram aleatoriamente divididos em 8 grupos experimentais (n=7): Adper Single Bond 2 (3M ESPE); Adper Scotchbond Multiuso (3M ESPE); Adper SE Plus (3M ESPE) e sistema adesivo P90 (3M ESPE), sendo os palitos obtidos de cada grupo divididos entre os testes envelhecidos ou não. Após a aplicação do sistema adesivo relacionado com cada um dos grupos, foi aplicada uma camada do adesivo da resina à base de silorano e fotopolimerizado por 10 segundos. O passo seguinte foi à inserção da resina composta Filtek P90 (3M ESPE) e fotoativação por 40 segundos com aparelho LED de segunda geração, o mesmo utilizado para a fotoativação dos sistemas adesivos. Para a resistência de união ao microcisalhamento ao esmalte, oitenta e quatro fragmentos foram obtidos a partir de superfícies proximais de quarenta e dois terceiros molares humanos (n=7). Os grupos foram os mesmos que os utilizados no ensaio de microtração acrescido de quatro grupos experimentais com condicionamento ácido prévio com ácido fosfórico 35% (3M ESPE) para os grupos que utilizaram os adesivos auto condicionantes, resultando em 12 grupos experimentais. As amostras foram testadas em 24 horas ou após 6 meses de envelhecimento. Os dados foram analisados estatisticamente por meio xii da análise de variância (ANOVA) com medidas repetidas e Teste de Tukey (p = 0,05) Os resultados mostraram que, para o teste de resistência à microtração, não houve diferença estatística significativa entre os grupos, nem para a interação (p > 0,05). No teste de microcisalhamento, o grupo condicionado com ácido fosfórico 35% + Adper SE Plus apresentou a maior resistência de união, no entanto, nenhuma diferença estatística entre o grupo condicionado com ácido fosfórico 35% + Sistema adesivo Silorano (p = 0,051) foi observada. O sistema Adesivo Silorano apresentou a menor resistência de união, sem diferença estatística entre o Adper SE Plus (p = 0,972). Para ambos os testes não houve diferença entre 24 horas e 6 meses (p> 0,05) de armazenamento. Pode concluir-se que os sistemas adesivos apresentaram comportamentos semelhantes na resistência de união à dentina; para o esmalte, o condicionamento ácido prévio aumentou os valores de resistência de união dos adesivos auto-condicionantes, promovendo um padrão de condicionamento que favorece a adesão a este substrato. O armazenamento por 24 horas e 6 meses não foi significativo para a resistência de união ao esmalte ou dentina / Abstract: The maintenance of the bond integrity between tooth and dental restoration is important for the clinical success of adhesive restorations, influencing their durability. Thus, the aim of this in vitro study was to evaluate the effect of different adhesive systems on the microtensile bond strength to dentin and microshear bond strength to enamel of silorane based resin after 24 hours and 6 months of storage. For this study seventy freshly extracted non-carious, unrestored human third molars were assigned to one of two bond strength test. For the microtensile bond strength, twenty-eight third human molars, with no roots, had their oclusal surface flattened in order to expose superficial dentin. Teeth were randomly assigned to 8 experimental groups (n=7): Adper Single Bond 2 (3M ESPE); Adper Scotchbond Multi-Purpose (3M ESPE); Adper SE Plus (3M ESPE) and P90 adhesive system (3M ESPE), the sticks being obtained from each group divided between tests aged or not. After application of the adhesive system related to each group, was applying only the silorane adhesive bond and then light cured for 10 seconds. The next step was the insertion of silorane composite resin Filtek P90 (3M ESPE) and light cured for 40 seconds with second-generation light-emitting diode, the same used for the light cured of the adhesive systems. For the microshear bond strength, eighty four fragments were obtained from proximal surfaces of forty two third human molars. Groups were the same as those used in the microtensile test increasing two more experimental groups with etching previous with phosphoric acid 35% (3M ESPE) for the self etch adhesive systems, resulting in 12 experimental groups (n=7). The samples were tested after 24 hours or after 6 months of aging. The data were statistically analyzed by repeated measure analysis of Variance (ANOVA) and Tukey's test (p=0.05). Results showed that for the microtensile bond strength there was no statistical difference for all groups, neither for interaction (p>0.05). For microshear bond strength, Etching with xiv phosphoric acid 35% + Adper SE Plus presented the highest bond strength, however no statistical difference between Etching with phosphoric acid 35% + Silorane System Adhesive (p=0.051) was observed. Silorane System Adhesive presented the lowest bond strength, without statistical difference from Adper SE Plus (p=0.972). There was no statistical difference between 24 hours and 6 months (p > 0.05). It can be concluded that there was no difference for the dentin bond strength group; for microshear bond strength, acid etching increases the bond strength values of the self-etching adhesive to enamel, promoting a conditioning pattern that favors the adhesion to this substrate. There was no statistical difference between the periods of 24 hours and 6 months of storage for enamel or dentin / Doutorado / Dentística / Doutora em Clínica Odontológica
225

Evaluation of mechanical properties of dental tissue of patients who undergone radiotherapy = Análise das propriedades mecânicas dos tecidos dentários de pacientes submetidos à radioterapia / Análise das propriedades mecânicas dos tecidos dentários de pacientes submetidos à radioterapia

Galetti, Roberta, 1985- 27 February 2015 (has links)
Orientadores: Alan Roger dos Santos Silva, Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T11:09:29Z (GMT). No. of bitstreams: 1 Galetti_Roberta_D.pdf: 1569073 bytes, checksum: f84fb18eb55733435da2efbd0ee7ed07 (MD5) Previous issue date: 2015 / Resumo: Este estudo avaliou o comportamento mecânico de tecidos dentários de pacientes com câncer de cabeça e pescoço submetidos à radioterapia. No capítulo I, o ensaio mecânico da nanoindentação foi utilizado para determinar a dureza e módulo de elasticidade do esmalte, dentina e da região de união restauradora em dentina (adesivo, camada híbrida e dentina subjacente). Foram utilizados seis dentes incisivos inferiores irradiados in vivo e não irradiados (grupos controle). A dureza e o módulo de elasticidade e foram obtidos após a realização da nanoindentação com pico de força de 1000 µN em dentina intertubular e região de união restauradora e 1500 µN em esmalte (centro do prisma) usando o microscópio de força atômica equipado com nanoidentador com tempo 5-2-5 seg para carregamento, aplicação e descarregamento da carga. A análise de variância a um fator foi aplicada com nível de significância de 0.05%. O valor da nanodureza e módulo de elasticidade não foram estatisticamente diferentes entre os tecidos avaliados em ambos os grupos irradiados e controle. Desta foma, pode-se concluir que tanto a dureza como o módulo de elasticidade de dentes submetidos à radioterapia in vivo não apresentam alterações das propriedades mecânicas no esmalte, dentina e região de união adesivo/dentina devido á ação direta da radioterapia. No capítulo II, foram avaliadas as propriedades viscoelásticas (storage e loss modulus) de três regiões diferentes: esmalte, junção amelo-dentinária (JAD) e dentina de dentes irradiados in vivo. Cinco dentes não irradiados (grupo de controle, n = 5) e cinco dentes irradiados in vivo (grupo irradiado, n = 5) foram utilizados para produzir cinco fatias de cada para avaliar a três áreas distintas: o esmalte, o JAD , e a dentina. A análise por mapeamento (Modulus Mapping Analysis) foi escolhida para avaliar a perda e armazenamento de energia mediante uma carga aplicada. Três regiões de dados foram coletados de cada área de tecido de cada fatia, totalizando quinze mapeamentos por tecido por grupo. Os valores do módulo foram calculados pelo software Hysitron® e a análise da variância (ANOVA Plot Split) e teste de Tukey a 5% de significância foram utilizados para comparar os grupos e tecidos. As três áreas avaliadas de ambos os grupos controle e irradiado revelaram diferença estatística no módulo de perda e armazenamento. Ambos os valores de perda e de armazenamento apresentaram-se maiores no grupo irradiado para esmalte (164,44 ± 36,60 GPa; 177,59 ± 58,84 GPa), JAD (50,85 ± 35,78 GPa; 83,33 ± 38,59 GPa) e dentina (21,18 ± 18,61 GPa; 52,44 ± 26,56 GPa) do que no grupo controle para o esmalte (127,15 ± 74,45 GPa; 162,85 ± 74,63 GPa), JAD (25,72 ± 9,64 GPa; 21,93 ± 52,78 GPa) e dentina (10,39 ± 8,65 GPa; 32,10 ± 20,39 GPa), respectivamente. Foi possível concluir neste estudo, que as propriedades viscoelásticas dos dentes irradiados in vivo apresentam-se diferentes das do grupo controle. Estes resultados sugerem que, após a radioterapia, os tecidos dentais estariam mais suscetíveis a fraturas / Abstract: This study evaluated the mechanic properties of enamel, dentin, and dentin bond interface of patients who undergone head and neck cancer treatment. On I chapter, the nanoindentation technique was used to determine the hardness (H) and reduced modulus of elasticity (Er) of the control group on enamel, dentin, and dentin bond interface (adhesive layer, hybrid layer and underlyer dentin). The Er and H were obtained after completion of nanoindentation with peak force of 1000 µN on intertubular dentin and restorative dentin interfaces and 1500 µN on enamel (prism center) using the atomic force microscope with nanoindenter accopled with test time 5-2-5 seconds for loading, holding and unloading. The one-way analysis of variance (p'< ou ='0.05) was applied and the valus for H and Er for both groups and tissues were no statistical different. As conclusion, the nanohardeness and elastic modulus behavior of the enamel, dentin and dentin bond interface was not impacted by the radiotherapy treatment of head and neck cancer. On II chapter, the viscoelastic properties were assessed (storage and loss modulus) of three different regions: enamel, dentin-enamel junction (DEJ) and dentin irradiated teeth in vivo. Five non irradiated teeth (control group, n=5) and five in vivo irradiated teeth (irradiated group, n=5) were used to produce five beams that were used to evaluate three different areas: the enamel, the DEJ, and the dentin. Perpendicular sections to the long axis of the teeth were made at middle region of the crown to produce the beams. The Modulus Mapping Analysis was chosen to evaluate the loss and storage moduli of each area. Three data regions were collected of each tissue area of each beam, summing a total of fifteen data per tissue per group. The modulus values were calculated by the Hysitron® software and an Analysis of Variance (ANOVA Split Plot) and Tukey test at 5% of significance was used to compare groups and tissues. All the three areas evaluated of control and irradiated group revealed statistical difference on the Loss and Storage Moduli. Both the loss and storage values are higer on the irradiated group for enamel (164.44±36.60 GPa; 177.59±58.84 GPa), DEJ (50.85±35.78 GPa; 83,33±38,59 GPa) and dentin (21.18±18.61 GPa; 52.44±26.56 GPa) than control group values for enamel (127.15±74.45 GPa; 162.85±74.63 GPa), DEJ (25.72±9.64 GPa; 21.93±52.78 GPa) and dentin (10.39±8.65 GPa;32,10±20,39 GPa), respectivally. The viscoelastic properties of in vivo irradiated teeth are different from control group. The enamel, DEJ and dentin presented the higer values on the in vivo irradiated group. These finds suggest that after radiotherapy, the dental tissues are more susceptible to fractures / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários
226

Influência do pré-tratamento dentinário com dimetilsulfóxido na resistência de união, exposição de matriz colágena e grau de conversão de sistemas adesivos = Influence of dimethyl sulfoxide-wet bonding technique on dentin bond strength, collagen exposure and monomer conversion of adhesive systems / Influence of dimethyl sulfoxide-wet bonding technique on dentin bond strength, collagen exposure and monomer conversion of adhesive systems

Stape, Thiago Henrique Scarabello, 1984- 27 August 2018 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T11:02:43Z (GMT). No. of bitstreams: 1 Stape_ThiagoHenriqueScarabello_D.pdf: 2806642 bytes, checksum: ff8fdbed5d394599068a4bc1d64d36c2 (MD5) Previous issue date: 2015 / Resumo: Essa tese avaliou um novo protocolo adesivo, que consiste no pré-tratamento dentinário com dimetilsulfóxido (DMSO) 50%, com o intuito de otimizar a durabilidade de interfaces adesivas produzidas pelos mecanismos de união convencional e autocondicionante envolvendo o substrato dentinário. Para isso, foram realizados dois estudos independentes para avaliar: (i) o efeito do uso do dimetilsufóxido (DMSO) na resistência de união imediata e na exposição de matriz colágena decorrente da hibridização dentinária na interface adesiva; e (ii) para avaliar o efeito do protocolo proposto na conversão monomérica na camada híbrida e na resistência de união após envelhecimento. Terceiros molares hígidos foram coletados e limpos, a face oclusal foi seccionada, expondo uma superfície dentinária de profundidade média, que foi saturada com uma solução aquosa de DMSO 50% (pH 8.2) após o condicionamento ácido para o sistema convencional de três passos (Adper Scothbond Multi-Purpose: 3M ESPE: SBMP) e previamente a aplicação do sistema autocondicionante de dois passos (Clearfil SE Bond: Kuraray; CF) no substrato mineralizado. Nos grupos controles, as amostras não foram tratadas com DMSO. Os segmentos restaurados com resina composta foram seccionados e submetidos ao ensaio de microtração após 24 h à 0,5 mm/min até a fratura (n=12) e no segundo estudo (n=10), após 1 ano e 2 anos. Foi realizada Two-way ANOVA para análise dos dados imediatos e no segundo estudo foi utilizada ANOVA medidas repetidas (proc mixed), ambos seguidos pelo Teste de Tukey (?=0.05). Foi realizado a análise histomorfométrica (n=12) para avaliação da extensão de matriz colágena exposta na interface adesiva por meio de microscopia ótica e coloração de Tricrômica de Masson após 24 h. Esses dados foram submetidos a Two-way ANOVA, seguido do Teste de Tukey (?=0.05). O grau de conversão monomérica (DC) na camada híbrida foi avaliado por espectroscopia micro-raman após 24 h (n=10), sendo submetidos a One-way ANOVA e Teste de Tukey (?=0.05). A interação entre protocolo adesivo e sistema adesivo influenciou significativamente a extensão de matriz colágena exposta (p<0,0001) e resistência de união imediata (p=0,0091). O protocolo adesivo com DMSO reduziu significativamente o grau de exposição de matriz colágena exposta (SBMP: 85,3% e CF: 61,5%), melhorando a qualidade da hibridização dentinária para ambos sistemas adesivos. Não houve influência negativa do DMSO na conversão monomérica do SBMP (p=0.892); já para o CF, houve aumento na conversão monomérica (p=0.033). O pré-tratamento com DMSO aumentou a resistência de união imediata do SBMP (p<0.0001). Considerando as amostras não tratadas, houve uma redução significativa (SBMP: 45,6% e CF: 36,8%) na resistência de união do SBMP (p<0.0001) e CF (p<0.0001) após dois anos de envelhecimento. Independentemente do tipo de adesivo, não houve diferença estatística na resistência de união entre valores imediatos e após 2 dois anos quando o DMSO foi empregado (p>0,05). A análise dos padrões de falha evidenciou uma tendência na redução no número de falhas adesivas após dois anos para as amostras tratadas com DMSO. Portanto, o protocolo adesivo proposto utilizando o DMSO é uma abordagem promissora para reduzir degradação da interface adesiva para os adesivos convencional e autocondicionante testados / Abstract: This work highlights a new bonding concept using 50% dimethyl sulfoxide (DMSO) as a dentin pre-treatment to optimize resin-dentin bonding for both etch-and rinse and self-etch adhesive systems after long-term aging. Two independent studies were performed: (i) to evaluate the effect of dimethyl sulfoxide wet-bonding technique on resin infiltration depths at the bonded interface and dentin bond strength; and (ii) to examine the effect of dentin pre-treatment with DMSO on the degree of conversion and dentin bond strength after long-term aging. Flat dentin surfaces derived from extracted sound human third molars were saturated with 50% DMSO (pH 8.2) after acid etching for a water-based etch-and-rinse adhesive system (Adper Scothbond Multi-Purpose: 3M ESPE; SBMP), and before acid primer application for a 10-MDP self-etch adhesive (Clearfil SE Bond: Kuraray; CF). In control groups, specimens were not treated with DMSO. The restored tooth segments were sectioned and submitted to microtensile bond strength test at 24 h (n=12), 1 year (n=10) and 2 years (n=10) at 0.5 mm/min until specimen fracture. One slab per tooth (n=12) was stained by Masson Trichrome and the extent of exposed collagen matrix at the bonded interface was evaluated using optical microscopy and a histomorphometric software at 24 h. Statistical analysis of the extension of collagen exposure was performed by two-way ANOVA followed by Tukey Test (?=0.05). The degree of conversion (DC) was measured inside the hybrid layer by micro-raman spectroscopy (n=10) at 24 h. DC statistical analysis was performed by One-way ANOVA and Tukey Test (?=0.05). Immediate microtesnile data was statistically analyzed Two-way ANOVA and aged data was analyzed by repeated measurres ANOVA (proc mixed). Post hoc multiple comparisons were performed by Tukey Test (?=0.05). The interaction between "dentin pre-treatment" and "adhesive system" significantly influence the extent of exposed collagen matrix (p<0.0001) and dentin bond strength (p=0.0091). The adhesive protocol with DMSO significantly reduced the extent of exposed collagen matrix (SBMP: 85.3% and CF: 61.5%), improving the quality of dentin hybridization for both adhesive systems. There was no negative influence of DMSO in monomer conversion for SBMP (p=0.892); nevertheless, there was an increase in monomer conversion (p=0.033) for CF. Dentin pretreatment with DMSO increased the immediate bond strength of SBMP (p<0.0001). Considering the untreated samples, there was a significant reduction (SBMP: 45.6% and CF: 36.8%) on the bond strength of SBMP (p<0.0001) and CF (p<0.0001) after two years of aging. Regardless of adhesive type, no significant reduction in bond strength at two years for DMSO-treated samples was observed. Fracture pattern analysis showed a tendency toward reduction in the number of adhesive failures when the DMSO-wet bonding was performed. Therefore, DMSO-wet bonding is a promising approach to reduce resin-dentin bond degradation of etch-and-rinse and self-etch adhesives / Doutorado / Dentística / Doutor em Clínica Odontológica
227

Estudo da união dentina-sistemas adesivos que não contém HEMA = avaliação do selamento dentinário, micropermeabilidade e da resistência de união à dentina imediata e à longo prazo = Adhesion study of dentin-HEMA-free adhesive systems : evaluation of dentin sealing, micropermeability and immediately and long-term dentin bond strength / Adhesion study of dentin-HEMA-free adhesive systems : evaluation of dentin sealing, micropermeability and immediately and long-term dentin bond strength

Sá, Renata Bacelar Cantanhede de, 1981- 28 August 2018 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-28T03:49:14Z (GMT). No. of bitstreams: 1 Sa_RenataBacelarCantanhedede_D.pdf: 1663244 bytes, checksum: ddbd6a5d390052ef93aca63cbdf510ab (MD5) Previous issue date: 2015 / Resumo: Este estudo avaliou o efeito de agentes cross-linking e a utilização de sistemas adesivos (SA) que não contém o monômero HEMA. No capítulo 1 foram avaliadas a resistência de união (RU) e o selamento dentinário (SD) após 24 horas e 6 meses de armazenamento em água. Para RU, foram avaliados 4 SA: um autocondicionante e um convencional contendo o monômero HEMA (Scotchbond Universal/SU e Prime & Bond Elect/PB), um autocondicionante e um convencional sem HEMA (G-Aenial/GA e All-Bond 3/AB) respectivamente. Cada SA foi subdividido em grupos baseados na biomodificação da dentina: controle (sem aplicação de agentes cross-linking), glutaraldeído 5% e proantocianidina 6,5% (PA). Após a aplicação dos adesivos com ou sem o uso de agentes cross-linking e aplicação do compósito, os dentes foram seccionados para obtenção de espécimes, os quais foram avaliados com o teste de microtração. O agente cross-linking que produziu os melhores resultados (PA) foi selecionado para o estudo de SD. Os espécimes foram preparados da mesma forma como descrito anteriormente. As mensurações de permeabilidade dentinária (PD) foram realizadas com a simulação da pressão pulpar através de uma coluna de água de 140 cm em 5 tempos (PD mínima: P min, PD máxima: P máx, PD após o uso do PA: PPA, PD após aplicação dos SA: PSA e PD após 6 meses: Parmazenado). Para o grupo controle, a mensuração difere na remoção da etapa correspondente a PPA, continuando com PSA e Parmazenado, respectivamente. No capítulo 2 foram avaliadas a RU, SD e micropermeabilidade de 4 SA: um convencional contendo HEMA (Adper Single Bond 2/SB), um adesivo de 3 passos que não contem HEMA no solução adesiva hidrófoba (AB) e dois autocondicionantes sem HEMA (GA e BeautiBond/BB). Os dentes foram preparados da mesma forma descrita no primeiro capítulo. A micropermeabilidade foi avaliada através da infiltração do corante amarelo de lúcifer na camada híbrida. Todas as metodologias foram avaliadas após 24 horas e 1 ano de armazenamento em saliva artificial. As mensurações de SD foram expressas em %. Os dados foram analisados com metodologia de modelos mistos para medidas repetidas para o primeiro capítulo e ANOVA 2 fatores e teste de Tukey (?=0,05). A RU produzida por PB, SU e AB não apresentou diferença entre eles e GA apresentou os menores valores em 24 horas. Todos SA apresentaram maiores RU com a aplicação do agente cross-linking PA em 24 horas, independentemente de possuírem HEMA na composição. Após armazenamento por 6 meses, SU e AB apresentaram redução da RU. PA e SA reduziram a permeabilidade da dentina e da interface dentina-resina, respectivamente. No segundo capítulo, AB apresentou maior RU seguido de SB e dos autocondicionantes (BB e GA) em 24 horas. GA apresentou o menor valor de RU após um ano, pois teve redução com o armazenamento. No SD em 24 horas, SB e AB selaram a dentina como a Pmin, enquanto BB não apresentou a mesma capacidade, porém manteve-se estável por um ano. Na avaliação da micropermeabilidade, ausência do HEMA não influenciou os resultados. Os resultados sugerem que a aplicação apenas do agente cross-linking PA pode produzir o selamento da dentina e aumentar a RU. Na segunda parte do estudo, o adesivo AB mostrou os melhores resultados nas análises de RU, SD e micropermeabilidade / Abstract: This study evaluated the effects of cross-linking agents and adhesive systems (AS) that not contain the monomer HEMA. In the chapter 1 the microtensile bond strength (BS) and dentin sealing (DS) after 24 hours and 6 months of water storage were evaluated. For BS teste, 4 groups AS were evaluated: a self-etch and one total-etch HEMA-containing adhesives (Scotchbond Universal/SU and Prime & Bond Elect/PB), one self-etch and one total-etch HEMA-free adhesives (G-Aenial/GA and All-Bond 3/AB). Each AS was divided into sub-groups based on dentin biomodification: control (no cross-linking agent application), 5% glutaraldehyde and 6.5% proanthocyanidin (PA). After adhesives application with or not cross-linking agent use, teeth were sectioned to obtain specimens, which were evaluated in microtensile bond strength test. The most promising dentin biomodification strategy (PA) was selected for DS study. The specimens were prepared in the same way as previous described. Permeability (PD) measurements study was carried out using a simulated pulpal pressure of 140 cm water column at 5 times of evaluation (minimum PD: Pmin, maximum PD: Pmax, PD after PA: PPA, PD after AS application: PAS and PD after 6 months: Pstored). For the control group, the measurements differ from PPA removal, continuing with PAS and Pstored, respectively. In the chapter 2, BS, DS and micropermeability of 4 AS: one total-etch HEMA-containing (Adper Single Bond 2/SB), one three-step etch-and-rinse adhesive that does not contain HEMA in hydrophobic solution (AB) and two self-etch HEMA-free (GA and BeautiBond/BB). The teeth were prepared in the same way as described in the chapter one. For micropermeability analysis the yellow lucifer was used and detected its penetration into the hybrid layer. All methods were tested after 24 hours and after 1 year of artificial saliva storage. DS measurements were expressed as %. The data were submitted to multiple comparisons using PROC MIXED for chapter one and two-way ANOVA and by Tukey¿s test (?=0.05) for chapter two. The BS of PB, SU and AB did not differ among them and GA showed the lowest values at 24 hours. PA cross-linking agent increased the BS for all at 24 hours, regardless the presence of HEMA. Storage for 6 months significantly decreased the BS for SU and AB. PA and AS decrease the permeability of the dentin and dentin-resin interface, respectively. In the chapter two, AB showed the highest values BS followed by SB and self-etch adhesives (BB and GA) at 24 hours. GA showed the lowest BS after one year because it was reduced. For DS, SB and AB sealed the dentin as Pmin, while BB and did not present the same ability, however kept stable after one year. The micropermeability revealed that the absence of HEMA did not influence the outcomes. Results suggested that PA cross-linking application alone was able to seal the dentin and increase the BS. In the second chapter, AB adhesive showed the best results in BS, DS and micropermeability analyses / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários / 2011/11415-1, BEPE 2013/02386-3 / FAPESP
228

Efeitos das estratégias adesivas sobre a adaptação marginal de dois tipos de selamento da dentina do acesso da cavidade endodôntica /

Sanchez Puetate, Cristian Fernando January 2018 (has links)
Orientador: Milton Carlos Kuga / Resumo: O selamento dentinário na câmara pulpar é frequentemente executado após o tratamento endodôntico, o qual é chamado de selamento endodôntico tardio (SET). A irrigação com Hipoclorito de Sódio (NaOCl) tem mostrado uma redução na resistência de união entre o dente e a resina. Porém, uma nova técnica denominada Selamento Endodôntico Imediato (SEI) tem sido proposta. O objetivo deste estudo foi comparar a eficácia da técnica do SEI, avaliando a adaptação interna de vários sistemas adesivos na dentina. Para isso 48 molares humanos foram instrumentados e distribuídos em seis grupos (n = 8), de acordo com o tipo de sistema adesivo utilizado e o momento de execução do SEI sendo esse antes da execução do tratamento endodôntico e SET após o tratamento endodôntico. Nos grupos G1-SBM- SEI / G4-SBM-SET foi utilizado um sistema adesivo "condiciona-e-lava" de três passos (Adper Scotchbond Multi-Purpose-SBM; 3M ESPE, St. Paul, MN, EUA), nos grupos G2-CF-SEI / G5-CF-SET sistema adesivo autocondicionante de dois passos (Clearfil SE Bond-CF; Kuraray, Osaka, Japão) e nos grupos G3-SBU-SEI / G6-SBU- SET) sistema adesivo autocondicionante de passo único (Scotchbond Universal- SBU; 3M ESPE, St. Paul, MN, EUA). Os dados obtidos na mensuração da penetrabilidade dos sistemas adesivos na dentina, por meio de microscopia confocal a laser, foram inicialmente submetidos ao teste de Shapiro-Wilk e, na sequência, aos testes de ANOVA e Tukey (P = 0.05). Por outro lado, os d... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The dentin sealing in the pulp chamber is often performed after the endodontic treatment, which is called late endodontic sealing (SET). Irrigation with sodium hypochlorite (NaOCl) has shown a reduction in bond strength between tooth and resin. However, a new technique called Immediate Endodontic Sealing (SEI) has been proposed. The objective of this study was to compare the efficacy of the SEI technique by evaluating the internal adaptation of several dentin adhesive systems. For this purpose 48 human molars were instrumented and distributed in six groups (n = 8), according to the type of adhesive system used and the moment of execution of the SEI, before the endodontic treatment and SET after the endodontic treatment. In the G1-SBM-SEI / G4-SBM-SET groups a conventional three-step adhesive system (Adper Scotchbond Multi-Purpose-SBM; 3M ESPE, St. Paul, MN, USA) was used. In groups G2-CF-SEI / G5-CF-SET was used as a self-etch adhesive system (Clearfil SE Bond-CF; Kuraray, Osaka, Japan) and G3-SBU-SEI / G6-SBU-SET groups was used a single-step self-etch adhesive system (Scotchbond Universal-SBU; 3M ESPE, St Paul, MN, USA).The data obtained in the measurement of the penetrability of dentin adhesive systems by laser confocal microscopy were initially submitted to the Shapiro-Wilk test and then to the ANOVA and Tukey tests (P = 0.05). On the other hand, the data obtained in the analysis of the scores attributed to the continuity of the hybrid layer were submitted to the Kruskal ... (Complete abstract click electronic access below) / Mestre
229

Infecções endodônticas primária x secundária : perfil microbiano, níveis de endotoxinas e ácido lipoteicóico, sinais e sintomas /

Machado, Felipe Paiva. January 2018 (has links)
Orientador: Marcia Carneiro Valera / Banca: Cláudio Antonio Talge Carvalho / Banca: Flaviana Bombarda de Andrade / Resumo: Esta pesquisa clínica teve como objetivo comparar a carga e composição microbiana bem como as concentrações de LPS e LTA encontradas na infecção endodôntica primária (IEP) e na infecção endodôntica secundária (IES). Além disso, a correlação desses achados com características clínicas e tomográficas também foram investigadas. Sessenta dentes de pacientes com IEP (31) e IES (29) foram submetidos à avaliação clínica e tomográfica, seguido do tratamento endodôntico ou retratamento. Amostras foram coletadas de cada canal radicular utilizando cones de papel. Logo após a abertura coronária (IEP) ou após a desobturação dos canais (IES) o conteúdo coletado foi submetido à técnica de cultura microbiológica para determinar a carga microbiana de bactérias anaeróbias e ao método Checkerboard DNA-DNA hybridization para investigação de espécies bacterianas presentes. O teste de Lisado de Amebócito de Limulus e o Ensaio de Imunoabsorção Enzimática foram utilizados para quantificar os níveis de LPS e LTA. Os dados obtidos foram correlacionados com os achados clínicos e tomográficos. Maiores quantidades de bactérias cultiváveis e de LPS foram encontradas na IEP (p < 0,05). Não houve diferença nos níveis de LTA entre IEP e IES (p > 0,05). A mediana de espécies por canal radicular encontrada na IEP foi de 9 espécies e na IES foi de 22 (p < 0,05). As espécies bacterianas mais prevalentes detectadas na IEP foram P. gingivalis (14/31) e S. intermedius (14/31). Na IES, as espécies mais prevalentes f... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This clinical research aimed to compare the microbial load and composition as well as the LPS and LTA concentrations found in Primary Endodontic Infection (PEI) and Secondary Endodontic Infection (SEI). In addition, the correlation of these findings with clinical and tomographic features was also investigated. Sixty patients' teeth with PEI (31) and SEI (29) were submitted to clinical and tomographic assessment, followed by endodontic treatment or retreatment. Samples were taken from each root canal using paper points. After the coronary opening (PEI) or after the removal of root filling material (SEI), the collected samples were submitted to the microbiological culture technique to determine the microbial load of anaerobic bacteria and to the Checkerboard DNA-DNA hybridization method for investigation of present bacterial species. The Limulus amebocyte lysate assay and enzyme-linked immunosorbent assay were used to quantify LPS and LTA levels. The data obtained were correlated with clinical and tomographic findings. A higher number of cultivable bacteria and LPS was found in PEI (p < 0.05). There was no difference in LTA levels between PEI and SEI (p> 0.05).The median number of species per root canal found in PEI was 9 and 22 in SEI (p < 0.05). The most prevalent bacterial species detected in PEI were P. gingivalis (14/31) and S. intermedius (14/31). In SEI, the most prevalent species were P. gingivalis (21/29) and C. rectus (20/29). LPS was positively correlated with a larg... (Complete abstract click electronic access below) / Mestre
230

Avaliação das propriedades de um sistema adesivo modificado por partículas de vidro bioativas /

Matuda, Amanda Guedes Nogueira January 2020 (has links)
Orientador: Rebeca [Unesp] Di Nicoló / Resumo: O objetivo desse estudo foi avaliar as propriedades de um sistema adesivo modificado com a incorporação de partículas de vidro bioativas (SCHOTT Bioactive Glass) em duas diferentes concentrações (0,5 e 1%). Foram avaliados a resistência de união da interface adesiva, o grau de conversão e a atividade antibacteriana, além da análise por meio do Estereomicroscópio e Microscópio Eletrônico de Varredura (MEV). Os adesivos foram divididos em três grupos: ASB - Adesivo Single Bond 2 (3M-ESPE) sem a incorporação de partículas bioativas, ASB0,5 – Adesivo Single Bond 2 com a incorporação de partículas bioativas na concentração de 0,5% e ASB1 – Adesivo Single Bond 2 com a incorporação de partículas bioativas na concentração de 1%. Para o teste de resistência de união foram utilizados 30 molares humanos hígidos (n=10) que posteriormente foram observados em Estereomicroscópio para análise do padrão da fratura. O grau de conversão foi feito no FTIR, onde foram feitas três leituras das gotas do adesivo dos diferentes grupos. A atividade antibacteriana foi feita através dos testes de difusão em ágar e contagem da unidade formadora de colônia (UFC), onde foram utilizados discos de adesivos polimerizados dos diferentes grupos. Os testes antibacterianos foram repetidos por três vezes. Os dados foram analisados estatisticamente quanto à sua normalidade. Como estes apresentaram distribuição normal, realizou-se o teste de análise de variância (ANOVA) paramétrica um fator (sistema adesivo) e o tes... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre

Page generated in 0.1404 seconds