• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Atividade antibacteriana de sistemas adesivos dentinários autocondicionantes sobre bactérias cariogênicas /

Gondim, Juliana Oliveira. January 2006 (has links)
Orientador: Elisa Maria Aparecida Giro / Banca: Josemeri Hebling / Banca: Regina Maria Puppin Rontani / Resumo: A incorporação de agentes antibacterianos aos sistemas adesivos dentinários autocondicionantes tem sido proposta com o intuito de eliminar bactérias residuais presentes na dentina, prevenindo, assim, a recorrência de cárie. O presente trabalho teve como objetivo avaliar a atividade antibacteriana dos sistemas adesivos dentinários autocondicionantes: Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) e Clearfil Tri-S Bond (C3SB), com e sem fotoativação, sobre bactérias cariogênicas, bem como a influência da dentina humana na atividade antibacteriana destes sistemas adesivos, utilizando o método de difusão em ágar. A solução de digluconato de clorexidina a 0,2% foi utilizada como controle positivo. O componente adesivo do CPB e do CSEB, o líquido A do XIII e o C3SB não apresentaram atividade antibacteriana quando aplicados sobre discos de papel. O conjunto primer e adesivo do CPB não fotoativado promoveu a maior inibição contra S. mutans (p<0,05), enquanto que com a fotoativação, não houve diferença entre esses componentes juntos e o primer isoladamente. Para o L. acidophillus, o primer do CPB apresentou a maior atividade antibacteriana nas duas condições de fotoativação (p<0,05). Quando os materiais foram aplicados sobre discos de dentina, somente a CHX promoveu efeito inibitório, o qual foi de menor intensidade do que quando aplicada sobre discos de papel (p<0,05). A CHX apresentou maior atividade antibacteriana sobre S. mutans quando comparado com L. acidophillus (p<0,05). Pode-se observar que a fotoativação reduziu significantemente a 18 atividade antibacteriana dos sistemas adesivos autocondicionantes, que a presença do MDPB no sistema adesivo dentinário é importante para a atividade antibacteriana sobre bactérias cariogênicas, e que a dentina atua como barreira de proteção eliminando ou reduzindo a ação antibacteriana de materiais odontológicos. / Abstract: The incorporation of antibacterial agents in self-etching dentin bonding systems has been introduced in attempts to eliminate dentin residual bacteria, preventing secondary caries. Therefore, the aim of this study was to evaluate the antibacterial activity of cured and uncured self-etching dentin bonding systems Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) and Clearfil Tri-S Bond (C3SB), against S. mutans and L. acidophillus, by the agar disc-diffusion test, as well as to evaluate the influence of human dentin on their antibacterial activity. A 0.2% aqueous solution of chlorhexidine (CHX) was used as a positive control. CPB and CSEB bond component, liquid A of Xeno III and C3SB did not show any antibacterial activity when applied onto paper discs. The primer and bond set of uncured CPB presented the strongest inhibitory activity against S. mutans (p<0.05), however after light-activation, no difference was observed between these components together and when primer was applied individually. Independently of light-activation conditions, CPB primer showed the strongest antibacterial activity against L. acidophillus (p>0.05). When the materials were applied onto dentin discs, only CHX presented inhibitory activity, which was less intense than when it was applied onto paper discs (p<0.05). CHX showed stronger antibacterial activity against S. mutans than against L. acidophillus (p<0.05). In conclusion, light-activation significantly reduced the antibacterial activity, the presence of MDPB in adhesive systems is important to the inhibitory effect against cariogênico 20 bacteria, and the dentin acted as a protection barrier reducing or inhibiting the antibacterial activity of dental materials. / Mestre
252

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Maria Angelica Silverio Agulhari 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).
253

"Influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos" / Thermal, mechanical load and pH cycling influence on adhesive systems bond strength to primary dentin.

Rachel de Oliveira Rocha 16 December 2004 (has links)
Nesta pesquisa foi realizada a avaliação da influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos. Para tal, cavidades oclusais foram preparadas em 80 molares decíduos e restauradas com os sistemas adesivos Single Bond e Clearfil SE Bond e resina composta Z100. Os dentes restaurados com cada um dos sistemas adesivos foram divididos em oito grupos (n= 5), de acordo com as condições de tratamento: ciclagem térmica (2000 ciclos, 5°C e 55°C), ciclagem de pH (10 ciclos, 8 horas de imersão em solução desmineralizadora e 16 em solução remineralizadora), ciclagem mecânica (100.000 ciclos, 8 kg), térmica/pH, térmica/mecânica, pH/mecânica e térmica/pH/mecânica, além do grupo controle. Os dentes foram seccionados perpendicularmente à interface de união e foram obtidos espécimes com área de superfície aderida com cerca de 0,8 mm 2 . Os espécimes foram submetidos ao teste de microtração e à análise do padrão de fratura em microscopia eletrônica de varredura. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p < 0,05). Não foram encontradas diferenças estatísticas significantes na comparação entre os sistemas adesivos avaliados nem para os grupos submetidos à aplicação dos estresses térmico, mecânico e térmico/pH. Os demais grupos apresentaram valores de resistência de união inferiores àqueles obtidos pelo grupo controle (p < 0,05) Fraturas do tipo adesiva/mista foram as mais prevalentes (95,9%). A resistência de união dos sistemas adesivos avaliados é negativamente influenciada pela aplicação combinada das tensões com naturezas distintas. / The influence of thermal, mechanical load and pH cycling on adhesive systems bond strength to primary dentin was evaluated. Occlusal cavities in 80 primary molars were prepared with diamond bur and restored with Single Bond and Clearfil SE Bond adhesive systems and Z100 composite. Teeth restored with each adhesive system were shared into eight groups according treatment condition: thermal cycling (2000 cycle, 5°C and 55°C), pH cycling (10 cycles, demineralization solution immersion to 8 hours and 16 hours in remineralization solution), mechanical load cycling (100.000 cycles, 8kg), thermal/pH, thermal/mechanical load, pH/mechanical load and thermal/pH/mechanical load, besides control groups. The teeth were transversally sectioned in two axis rendering 0,8mm 2 stick shaped specimen. Sticks were then submitted to microtensile bond testing with a crosshead speed of 1mm/min. Fracture analysis was performed by scanning electron microscopy. Bond strength means expressed in MPa were submitted to two-wav ANOVA (p<0.05). No statistically significant differences were found between the adhesive systems nor to thermal, mechanical load and thermal/pH stresses groups. Lower bond strength values were found to other groups compared to control (p<0.05). Adhesive/mixed failures were prevalent (95.9%). Bond strengths of evaluated adhesive systems were negatively influenced by distinct tension application.
254

Influência da umidade e temperatura intrabucais na resistência de união de sistemas adesivos convencionais de dois passos à dentina : estudo in situ.

Saraiva, Letícia Oliveira January 2008 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:30:00Z No. of bitstreams: 2 Dissertacao Leticia Saraiva2.pdf: 1296302 bytes, checksum: 1e07502c1e338a38db482de4808d32f7 (MD5) Dissertacao Leticia Saraiva1.pdf: 179952 bytes, checksum: cf1d7c8753ea10452ef96eb6607fddad (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:04:08Z (GMT) No. of bitstreams: 2 Dissertacao Leticia Saraiva2.pdf: 1296302 bytes, checksum: 1e07502c1e338a38db482de4808d32f7 (MD5) Dissertacao Leticia Saraiva1.pdf: 179952 bytes, checksum: cf1d7c8753ea10452ef96eb6607fddad (MD5) / Made available in DSpace on 2013-05-16T18:04:08Z (GMT). No. of bitstreams: 2 Dissertacao Leticia Saraiva2.pdf: 1296302 bytes, checksum: 1e07502c1e338a38db482de4808d32f7 (MD5) Dissertacao Leticia Saraiva1.pdf: 179952 bytes, checksum: cf1d7c8753ea10452ef96eb6607fddad (MD5) Previous issue date: 2008 / O presente estudo teve como objetivos avaliar o efeito das condições de temperatura e umidade relativa intrabucais na resistência de união à dentina de dois sistemas adesivos convencionais de dois passos (Single Bond 2/SB2 e One Step Plus/OSP), e avaliar a umidade e a temperatura presentes nas regiões de incisivos e molares superiores. Sessenta fragmentos dentários foram esterilizados, fixados em moldeiras de acetato individualizadas, e posicionados in situ em um voluntário para serem restaurados com resina composta, sendo aleatoriamente divididos em seis grupos, de acordo com o sistema adesivo e com a condição de temperatura e umidade: G1 – SB2 na condição ambiental de um consultório odontológico; G2 – SB2 na condição da região de incisivos; G3 – SB2 na condição da região de molares; G4 – OSP na condição ambiental de um consultório odontológico; G5 – OSP na condição da região de incisivos e G6 – OSP na condição da região de molares. Em todas as condições, foram obtidas e registradas a temperatura e a umidade relativa do ar no momento e no local em que as restaurações foram produzidas, usando um termo-higrômetro digital. Após ensaio de microtração, os dados do teste de resistência de união foram submetidos à análise estatística (ANOVA - 2 fatores/ Teste de Tukey, α=5%) e os valores médios em MPa foram: G1 = 20,2 (7,6); G2 = 23,0 (6,5); G3 = 22,7 (6,0); G4 = 29,0 (5,8); G5 = 29,7 (4,9) e G6 = 27,7 (4,8). Os resultados demonstraram que os grupos que utilizaram o OSP (G4, G5 e G6) apresentaram médias semelhantes entre si (p=0,67) e maiores do que os grupos que utilizaram o SB2 (G1, G2 e G3) (p=0,001), também semelhantes entre si (p=0,67). Foi observado que as condições de temperatura presentes nas regiões intrabucais (incisivos e molares) foram semelhantes entre si, e maiores que a condição ambiental do consultório odontológico. A condição de umidade na região de molares foi superior à condição na região de incisivos, e esta foi maior do que a condição presente no ambiente do consultório odontológico. As condições de temperatura e umidade intrabucais não influenciaram a resistência de união dos sistemas adesivos simplificados à dentina. O sistema adesivo One Step Plus apresentou melhores resultados que o sistema Single Bond 2, independentemente das condições de umidade e temperatura. / Salvador
255

Sistemas adesivos convencional e autocondicionante : análise micromecânica tridimensional da interface dentina-adesivo /

Martin Júnior, Manoel. January 2008 (has links)
Orientador: Eduardo Passos Rocha / Banca: Marco Antonio Luersen / Banca: Renato Herman Sundfeld / Banca: Marcelo Giannini / Banca: Washington Rodrigues Camargo / Resumo: OBJETIVO: Avaliar a distribuição das tensões na interface dentina-adesivo variando o sistema adesivo, convencional e autocondicionante, através do método dos elementos finitos tridimensional. MATERIAL E MÉTODO: Foram elaborados 4 modelos no programa Solidworks 2007, sendo: Mc - representação de um espécime em dentina (41x41x82 μm) restaurado com resina composta (RC), apresentando camada de adesivo, camada híbrida (CH), TAGs, dentina peri-tubular, dentina intertubular parcialmente desmineralizada, dentina intertubular e prolongamento odontoblástico, simulando a formação da CH segundo o sistema adesivo convencional; Mr - idêntico ao Mc, com ramificações laterais do infiltrado do adesivo; Ma - idêntico ao Mc, sem TAGs, e com "smear plug", simulando o sistema adesivo autocondicionante; Mat - idêntico ao Ma, com TAGs. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos e a análise numérica foi realizada no ANSYS Workbench 10.0 para obtenção da máxima tensão principal (MAX) após aplicação de força de tração de 0,03 N perpendicular à superfície da RC. A base de todos os modelos foi fixada nos eixos x, y e z. RESULTADOS: A MAX foi maior para o sistema convencional. A presença da ramificação lateral aumentou a MAX na CH para o sistema convencional. Os TAGs modificaram a distribuição da MAX na camada de adesivo para o sistema autocondicionante. CONCLUSÃO: A CH para o sistema convencional apresentou maior MAX em comparação ao sistema autocondicionante. A presença das ramificações laterais do adesivo aumentaram a tensão na CH para o sistema convencional. / Abstract: OBJECTIVE: The aim of this study was to evaluate the stress distribution in the hybrid layer varying the adhesive system (total each and self-etching systems) using three-dimensional finite element analysis (FE). METHODS: 4 FE models (M) were developed in Solidworks 2007: Mc - representation of a specimen of dentin (41x41x82 μm) restored with composite resin (RC), showing the adhesive layer, hybrid layer (HL), TAGs, peri-tubular dentin, intertubular dentin in order to simulate simulating the HL according to the total-etch adhesive system; Mr - similar to Mc, with lateral branches of the adhesive; Ma - similar to Mc, without TAGs and showing the "smear plug" in order to simulate the environment for the self-ethcing adhesive system; Mat - similar to Ma, with TAGs. The models were considered isotropic, homogeneous and linearly elastic and numerical analysis was performed in ANSYS Workbench 10.0 to obtain the maximum principal stress (MAX) after application of a tension force of 0.03N perpendicular to the surface of the RC. The botton of all models was fixed in x, y and z axis. RESULTS: The highest MAX in HL was observed in the total etching system. The lateral branches increased the MAX in HL. The TAGs had a little influence on the stress distribution in self-ethching system. CONCLUSION: The HL for the total-etch system showed MAX higher in comparison with the self-etch system. The presence of TAGs increased the MAX in the HL for the total-etch system. / Doutor
256

Efeito do tempo de condicionamento na degradação da união resina-dentina decídua

Sanabe, Mariane Emi [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T20:17:11Z : No. of bitstreams: 1 sanabe_me_me_arafo.pdf: 801888 bytes, checksum: c29d9fba1c2e1a1219458d7df6abd318 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O presente estudo teve como objetivo investigar o efeito da redução do tempo de condicionamento da dentina decídua na resistência de união imediata de um sistema convencional e um autocondicionante, e na degradação da união resina-dentina após 6 meses de armazenagem em água. Foram utilizados quarenta e oito molares decíduos hígidos foram aleatoriamente divididos em 4 grupos (n=12) de acordo com o sistema adesivo (Adper Single Bond e Clearfil SE Bond) e o tempo de condicionamento da dentina (como recomendado pelo fabricante e metade desse tempo). Desta forma, o sistema Single Bond foi aplicado sobre a dentina condicionada com ácido fosfórico a 35% por 15 ou 7 segundos, enquanto que o sistema Clearfil SE Bond foi aplicado à dentina condicionada com SE Primer por 20 ou 10 segundos. Em seguida, coroas em resina composta foram reconstruídas incrementalmente e os dentes foram mantidos hidratados em estufa à 37o C por 24 horas. Dez dentes de cada grupo foram utilizados para o ensaio mecânico de microtração. Os demais foram preparados para análise da interface adesiva em MEV. Espécimes em forma de pilar de secção transversal quadrangular (0,49 mm2) foram obtidos e divididos de acordo com a condição de armazenagem, 24 horas em água (controle), 6 meses em água e 6 meses em óleo. Os espécimes foram tracionados a velocidade de 0,5 mm/min em máquina de ensaios mecânicos e as fraturas classificadas em adesiva, coesiva em dentina, coesiva em resina ou mista. Os dados foram analisados estatisticamente pela análise de variância e testes complementares de comparação múltipla, considerando-se o nível de significância de 5%. Após 24 horas de armazenagem, os sistemas adesivos apresentaram valores de resistência de união comparáveis estatisticamente, não influenciados pela redução do tempo de condicionamento ácido... . / To evaluate the effect of reducing the acid etching of primary dentin on the immediate bond strength of a conventional and a self-etching primer system, and on the degradation of the resin-dentin bonds after 6 months aging. Forty-eight sound primary molars were randomly divided into 4 groups of investigation (n=12) according to the adhesive system (Adper Single Bond and Clearfil SE Bond) and the period of acid etching (as recommended by the manufacturers and half of this time). Single Bond was applied to dentin after 35% phosphoric acid etching for 15 seconds or 7 seconds, whereas Clearfil SE Bond was applied to dentin after the application of SE Primer for 20 seconds or 10 seconds. Following the adhesive systems, composite resin crowns were incrementally built-up and the teeth were stored in water at 37o C for 24 hours. Specimens with a cross-sectional area of 0,49 mm2 were produced from each one of the teeth (10 teeth per group) and further divided according to the storage condition, 24 hours in water, 6 months in water and 6 months in mineral oil, when they were tested under tension until failure in a machine operating at a cross-head speed of 0.5 mm/min. After the microtensile test, the failures were classified as adhesive, cohesive in dentin, cohesive in resin or mixed. The two remaining teeth per group were prepared to SEM evaluation of the interfaces. Two-way analysis of variance and multiple comparison testes were applied at a significance level of 5%. When bond strength was evaluated after 24 hours storage in water there was no significant difference between the adhesive systems, irrespective of the periods of acid etching. For Single Bond, water storage for 6 months in water significantly reduced bond strength, especially when the dentin was phosphoric acid conditioned for 15 seconds (36.7% reduction). For Clearfil SE Bond... (Complete abstract, click electronic address below).
257

Influência do substrato, dentes decíduos e permanentes, e da aplicação de clorexidina na resistência de união de sistemas adesivos à dentina

Ricci, Hérica Adad [UNESP] 31 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-31Bitstream added on 2014-06-13T20:56:55Z : No. of bitstreams: 1 ricci_ha_me_arafo.pdf: 5754371 bytes, checksum: 74988ba41e6d82c0fe9ae7a66dd7310d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Proposição: O objetivo deste trabalho, dividido em três estudos, foi (1) investigar o efeito do substrato, dentina de dentes decíduos e permanentes, assim como (2) o efeito imediato e (3) em longo prazo, da aplicação de clorexidina pós-condicionamento ácido da dentina na resistência de união (RU) de sistemas adesivos. Materiais e Métodos: Nos estudos 1 e 2, realizados in vitro, foram utilizados molares decíduos e pré-molares, divididos em três grupos segundo a aplicação dos sistemas adesivos Prime & Bond NT, Adper Single Bond e Excite DSC. Sobre superfícies planas em dentina, foi realizado o condicionamento com ácido fosfórico a 35% por 15 s, o qual foi removido com lavagem abundante. Após remoção do excesso de umidade, os sistemas adesivos foram aplicados segundo a recomendação dos fabricantes. Apenas para o estudo 2, em 50% dos dentes para cada sistema adesivo foram aplicados 20 μL de clorexidina a 2% por 60 s sobre a dentina condicionada. Seguida à aplicação dos sistemas adesivos, as coroas foram reconstruídas em resina composta. Para o estudo 3, foram selecionados 13 voluntários que apresentavam no mínimo 2 molares decíduos contralaterais com lesão de cárie oclusal, sendo os dentes aleatoriamente designados aos grupos controle ou experimental. Após o preparo cavitário, no grupo controle, 5 μL de água destilada foram aplicados sobre a dentina condicionada com ácido fosfórico, enquanto no grupo experimental foi aplicado o mesmo volume de solução de clorexidina 2%. Os dentes foram restaurados com Prime&Bond NT e resina Z250 e recuperados quando da esfoliação, definindo os períodos de função na cavidade bucal como até 30 dias, de 1 a 5, de 10 a 12 e de 18 a 20 meses. Para todos os experimentos, os dentes foram cortados em espécimes com área transversal aproximada de 0,81mm² para realização do ensaio mecânico de microtração... / Purpose: The aim of this work, divided in three studies, was to investigate (1) the effect of the substrate, dentin of primary and permanent teeth, as well as, (2) the effect of chlorhexidine application after acid etching on the immediate and (3) long-term bond strength of adhesive systems to dentin. Materials and Methods: In studies 1 and 2, performed in vitro, primary molars and pre-molars were assigned to three groups according to the adhesive systems Prime & Bond NT, Adper Single Bond and Excite DSC. Flat dentin surfaces were etched with 35% phosphoric acid for 15 s, followed by abundant water rinse. After the removal of the excess of water, the adhesive systems were applied following the manufacturer´s instructions. Only in study 2, fifty percent of the teeth for each adhesive system received the application of 2% chlorhexidine for 60 s after acid etching. Following the application of the adhesive systems, the crowns were rebuilt in composite resin. In study 3, thirteen volunteers were included which had at least one pair of primary contralateral molars with occlusal caries lesions. The teeth were randomly assigned into the control or experimental group. After the class I cavity preparation, for the control group, five microliters of distilled water were applied on the phosphoric acid etched dentin, while for the experimental group the same volume of 2% chlorhexidine was used. The cavities were restored with Prime&Bond NT and Z250 resin and the teeth were retrieved after exfoliation defining the periods of function in the oral cavity as up to 30 days, 1-5, 10-12 and 18-20 months. In all studies, the teeth were cut to produce beams with 0.81 mm² cross-sectional area, which were subjected to the microtensile test. Bond strength (μTBS) data were submitted to ANOVA and Tukey statistical tests (α=0.05). Results: There was no statistically significant difference for μTBS values...(Complete abstract click electronic access below)
258

AVALIAÇÃO IN VIVO E IN VITRO DE TERAPIAS DE USO EM CONSULTÓRIO PARA O TRATAMENTO DA HIPERSENSIBILIDADE DENTINÁRIA / IN VIVO AND IN VITRO ASSESSMENT OF IN-OFFICE THERAPIES USED FOR TREATING DENTINAL HYPERSENSITIVITY

Osmari, Deise 06 December 2011 (has links)
Dentinal hypersensitivity (DH) is a frequent clinical situation that is characterized by discomfort with pain ranging from slight to unbearable and it requires the professional to choose the appropriate therapy. Therefore, the aim of this study was to perform a clinical and morphological assessment of four in office therapies used for treating DH. The desensitizing therapies assessed were as follows: G1: fluoridated varnish (Control Group); G2: potassium oxalate; G3: hybridization with an adhesive system; G4: high-power diode laser. Twenty patients participated in the randomized, double-blind, controlled and split-mouth clinical study, each patient with 1 eligible tooth in each quadrant. Pain was measured using the Visual Analog Scale (VAS) after evaporative stimulus before the beginning of treatment, soon after the procedure and 15, 30 and 60 days after each application. The values of VAS immediately after the therapies, as well as after 15, 30 and 60 days, were compared to baseline values by the Wilcoxon test (non-parametric paired data) (α=0.05). The variation (Δ) in the VAS after each experimental group (VAS x days VAS baseline) was compared among the four experimental groups by ANOVA, following the Tukey s post hoc test (α =0.05). Fifteen dentin blocks (n=3) were obtained from the cervical third of vestibular faces of human pre-molar teeth for morphological analysis. Enamel was removed to expose dentin surface, polished with silicon carbide abrasive papers, and etched with 6% citric acid for 2 minutes. After therapies, the specimens were fractured in the buccolingual direction and prepared for analysis under Scanning Electron Microscope. The specimens were analyzed qualitatively both from the view of the buccal surface view and fractured surface. The variation of VAS immediately after therapies, subtracting the baseline value of VAS, differed among the groups. The highest value was found in G1 (fluoridated varnish) and the lowest value in G3 (adhesive system). With regard to VAS, no statistically significant differences among the therapies were found after the time intervals that corresponded to the assessments after 15, 30 and 60 days. In the group without treatment, etching removed the smear layer and exposed the dentinal tubules. A film on the surface with infiltration of varnish plugs into the tubules was found in the fluoridated varnish group. The oxalate group presented partial occlusion of the tubules with formation of crystals inside them. The tubules in the adhesive system group were obliterated by the formation of hybrid layer and a mechanical barrier on the surface. The high-power diode laser altered dentin superficially during melting and re-solidification, which partially occluded the tubules. All treatments were effective in reducing DH within the 60-day period and all desensitizing agents have shown the ability to modify the dentin surface by partially or completely occluding the dentinal tubules. / Caracterizada pelo desconforto causado por dores leves até insuportáveis, a hipersensibilidade dentinária (HD) é uma situação clínica frequente, exigindo do profissional o desafio da escolha de uma terapia adequada. Assim, este trabalho teve por objetivo realizar uma avaliação clínica e morfológica da ação de quatro terapias de uso em consultório no tratamento da HD. As terapias dessensibilizantes avaliadas foram: G1: verniz fluoretado (grupo controle); G2: oxalato de potássio; G3: hibridização com sistema adesivo; G4: laser de diodo em alta potência. O estudo clínico, randomizado, controlado, duplo cego, com desenho de boca-dividida contou com a participação de 20 pacientes, com um dente elegível em cada quadrante, sendo a dor quantificada através da Escala Visual Analógica (EVA) após estímulo evaporativo, antes do início do tratamento, logo em seguida à aplicação e após 15, 30 e 60 dias. Os valores da EVA após a aplicação das terapias, bem como após 15, 30 e 60 dias, foram comparados aos valores do baseline por meio de teste de Wilcoxon (dados pareados não paramétricos) (α=0,05). A variação (Δ) na EVA após cada período experimental (EVA xdias - EVA baseline) foi comparada entre os quatro grupos experimentais por meio de ANOVA, seguido de teste post hoc de Tukey (α =0,05). Para a análise morfológica foram obtidos 15 blocos de dentina (n=3) do terço cervical da face vestibular de pré-molares humanos extraídos. O esmalte foi removido para expor a superfície dentinária, sendo realizado o polimento com lixas de carbeto de silício e o condicionamento com ácido cítrico 6% por 2 min. Após a aplicação das terapias, os espécimes foram fraturados no sentido linguo-vestibular, e preparados para análise no microscópio eletrônico de varredura, sendo analisados tanto na vista da superfície vestibular quanto da superfície clivada, de forma qualitativa. Quando verificada as médias da EVA, encontrou-se efetiva ação dessensibilizante imediata no grupo do verniz fluoretado e do oxalato de potássio, sendo que aos 60 dias, todos os grupos estudados apresentaram efeito dessensibilizante significativo. A variação da EVA (EVA xdias - EVA baseline) após a aplicação imediata das terapias, subtraída do valor da EVA no baseline, diferiu entre os grupos, sendo maior no G1 (verniz fluoretado) e menor no G3 (Sistema adesivo). Nos períodos que corresponderam às avaliações de 15, 30 e 60 dias, não houve diferença estatística entre as quatro terapias quanto à variação na EVA. Na análise morfológica do grupo sem tratamento, o condicionamento promoveu remoção de smear layer e exposição de túbulos dentinários. No grupo do verniz fluoretado observou-se uma película sobre a superfície, com plugs de verniz infiltrados nos túbulos. No grupo do oxalato ocorreu oclusão parcial da embocadura do túbulo, com formação de cristais em seu interior. O grupo do sistema adesivo obliterou os túbulos pela formação da camada híbrida e de uma cobertura superficial. O laser de diodo em alta potência causou leve derretimento e ressolidificação, ocluindo parcialmente os túbulos. Todos os tratamentos foram efetivos na redução da HD no período de 60 dias, sendo que todos os agentes dessensibilizantes mostraram capacidade de modificar a superfície da dentina, ocluindo de forma parcial ou total os túbulos dentinários.
259

Resistência de união da resina composta à dentina irradiada com laser de Nd:YAG, utilizando o teste de microtração /

Castro, Fabrício Luscino Alves de. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Maria Salete Machado Cândido / Banca: Luís Geraldo Vaz / Banca: Paulo Sérgio Quagliatto / Banca: Marcela Rocha de Oliveira Carrilho / Resumo: Este estudo avaliou, por meio do teste de microtração, a resistência de união da resina composta à dentina, verificando a influência da irradiação do tecido com laser de Nd:YAG, realizada após a aplicação do adesivo, e associada ou não ao pré-tratamento ácido do mesmo. Superfícies dentinárias planas foram criadas em 37 terceiros molares humanos extraídos, dos quais, 36 foram selecionados para teste. Os adesivos Single Bond (SB) e Clearfil SE Bond (CSEB) foram aplicados, com ou sem o condicionamento da dentina (ácido fosfórico para o SB e "primer" auto-condicionante para o CSEB). Após aplicação dos adesivos e antes de sua fotopolimerização, as superfícies foram irradiadas com laser, exceto para os controles, testando-se duas potências, 0,75 e 1W. No total, 12 grupos foram criados, 6 para cada sistema. Coroas de resina composta foram construídas e os dentes armazenados a 37ºC por 24h. Depois, os mesmos foram cortados serialmente, resultando em espécimes com secção transversal de união aproximada de 0,49mm2, que foram, em seguida, testados sob tração. Espécimes fraturados, representativos dos diferentes grupos, tiveram suas superfícies dentinárias observadas ao microscópio eletrônico de varredura (MEV). As interfaces adesivas de 2 espécimes não testados em cada grupo também foram observadas ao MEV. O sistema SB foi aplicado na superfície do dente remanescente (sem ácido e sem laser), a coroa de resina construída e o conjunto seccionado em duas metades, para observação da interface ao MEV. Os resultados mostraram que a aplicação do laser aumentou a resistência à microtração apenas quando o SB foi aplicado sem o condicionamento ácido prévio e em relação ao grupo em que só o adesivo foi aplicado (SB / sem ácido/ sem laser). Entretanto, estes valores foram inferiores aos obtidos quando o SB foi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated if the irradiation of dentin trough the adhesive applied on it affected micro-tensile bond strength of composite to this tissue. Flat dentin surfaces were created in 37 extracted human third molars. Thirty-six teeth were selected and received surface treatments. Single Bond (SB) and Clearfil SE Bond (CSEB) systems were individually applied after dentin had been acid-etched or not, with phosphoric acid for SB or self-etching primer for CSEB. Immediately after adhesives application and before light curing, surfaces were lased, except for controls, using two power settings, 0.75 and 1W. So, 12 groups were designed, 6 for each bonding system. After that, composite crowns were built-up over the treated surfaces and the teeth were stored in distillated water, at 37ºC, for 24h. The teeth were serially sectioned in beams with cross-sectional area of approximately 0,49mm2, and the specimens were stressed to failure under tension using a testing machine. Representative fractured specimens were selected and had their dentin surfaces observed under scanning electron microscopy (SEM). Interfaces of two untested beams were also observed under SEM. Moreover, the dentin surface of one additional tooth received SB application (with neither acid etching nor laser irradiation), a composite crown was built-up on it and the tooth was cut longitudinally in two halves, which had their dentin/resin interfaces observed under SEM. This study showed that laser irradiation increased micro-tensile bond strength only in Groups 5 and 6, where SB was applied without previous dentin acid etching, in comparison to the group where this adhesive was used alone (Group 4 - no etching / no laser). However, these values were lower than those found when dentin was etched. There was not an improvement in bond... (Complete abstract, click electronic address below) / Doutor
260

"Desinfecção da Dentina Radicular pela Irradiação dos Lasers de Nd: YAG e Er: YAG: um Modelo "in vitro"" / Disinfection of intracanal dentin by ND:YAG, HO:YAG and ER:YAG laser irradiation: an in vitro model

Silvia Cristina Mafra Cecchini 05 July 2001 (has links)
RESUMO Desinfecção da dentina radicular pela irradiação dos lasers de ND:YAG, HO:YAG e ER:YAG: um modelo in vitro A provável causa do insucesso da terapia endodôntica é a persistência de microrganismos colonizando os túbulos dentinários. Para reduzir o risco de insucesso e, se possível, o tempo despendido no tratamento endodôntico, novos equipamentos e materiais são constantemente desenvolvidos. O objetivo desta investigação foi estudar o efeito da irradiação laser intracanal na desinfecção dos túbulos dentinários de dentes bovinos recém-extraídos, utilizando-se um modelo in vitro. Os grupos irradiados pelos vários lasers foram comparados ao tratamento com hidróxido de cálcio, freqüentemente utilizado como medicação intracanal. O cemento radicular foi removido, o canal preparado e os dentes, cortados, resultando em 180 corpos de prova padronizados. Para promover a colonização bacteriana, os corpos de prova foram incubados, a 37 o C, em frascos contendo caldo de tripticase de soja e Enterococcus faecalis, o qual continha um plasmídeo que permitiu o seu crescimento em um meio seletivo com cloranfenicol. Os corpos de prova foram divididos em cinco grupos experimentais e três grupos-controle. Para irradiação foram utilizados os lasers pulsados de: Ho:YAG a 2,1 µm; Nd:YAG (1,06 µm); e Er:YAG (2,94 µm) com e sem refrigeração ar/água. Os grupos tratados receberam três parâmetros diferentes de irradiação com cada tipo de laser: energia abaixo do limiar de modificação física (physical modification threshold - ½ do PMT) por 60s; no limiar (PMT) por 60s; e, acima do limiar (120s). O Grupo 5 recebeu sete dias de tratamento com hidróxido de cálcio. Como controles, três espécimes para cada grupo receberam água estéril (controle negativo), três receberam KI3, após exposição à bactéria (controle negativo) e três não receberam tratamento após exposição à bactéria (controle positivo). A quantidade de bactérias foi estimada mediante a contagem de unidades formadoras de colônias (u.f.c.). De modo a avaliar, paralelamente, se os comprimentos de onda laser utilizados no experimento poderiam ser absorvidos pelo E. faecalis, foram obtidos espectros de absorção no UV, VIS e IR, por meio de espectroscopia. A análise estatística mostrou uma redução bacteriana como segue: Ho:YAG > hidróxido de cálcio > Nd:YAG > Er:YAG com refrigeração ar/água > Er:YAG sem refrigeração ar/água. Houve uma significativa redução bacteriana no grupo irradiado pelo Ho:YAG no limiar de modificação – PMT (50 mJ, 10 Hz, 66 J/cm 2 , por 120s), seguida pelo Ho:YAG a 50 mJ, 10 Hz, 33J/cm 2 , por 60s e pelo grupo que recebeu hidróxido de cálcio. Os dois últimos grupos não apresentaram diferenças estatísticas significativas. O espectro de absorção pelas bactérias (E. faecalis) nas faixas dos comprimentos de onda do UV e VIS apresentou picos de absorção em 361 nm e em 377 nm (UV). Já o infravermelho próximo revelou uma baixa absorção pelo microrganismo testado. / SUMMARY Disinfection of intracanal dentin by Nd:YAG, Ho:YAG and Er:YAG laser irradiation: an in vitro model A possible cause for root canal failure is the persistence of bacteria that have colonized dentinal tubules. To reduce this risk and, if possible, to also shorten the time-consuming endodontic therapy, new equipment and materials are constantly being introduced. The aim of the present investigation was to study the effect of disinfection of dentinal tubules by intracanal laser irradiation using an in vitro model. The groups irradiated by various lasers were compared with calcium hydroxide, a material frequently used as intracanal medication between appointments. Freshly extracted, intact bovine incisors were used. The root cementum was removed and the teeth cut to produce 180 standardized specimens. For bacterial colonization, specimens were incubated at 37 o C in test tubes with Tryptic Soy Broth and Enterococcus faecalis, which carried a plasmid that allowed the growth in a selective medium containing chloramphenicol. The specimens were divided in five treatment groups and three control groups. For irradiation, pulsed delivered Ho:YAG laser at 2.1 µm, Nd:YAG laser (1.06 µm), and Er:YAG and Er:YAG laser (2.94µm) with and without air/water coolant, were used. Lasers groups received three different laser settings for treatment: output energy below the physical modification threshold (½ of PMT) for 60 sec, at the PMT for 60 sec and above the PMT (120 sec). Group 5 received a seven-day treatment with calcium hydroxide. As controls, three specimens for each treatment group received sterile water instead of bacteria (negative control), three received iodine potassium-iodide after bacterial exposure (negative control), and three did not receive treatment after bacterial exposure (positive control). The number of bacteria was estimated by counting CFU. In order to evaluate whether the lasers used in the experiment could be absorbed by the bacteria E. faecalis, an UV, VIS and NIR spectra were obtained using a spectrophotometer. Statistical analysis showed the bacterial reduction as follow: Ho:YAG laser > hidróxido de cálcio> Nd:YAG laser > Er:YAG laser with air/water coolant > Er:YAG laser without air/water coolant. There was a significantly higher bacterial reduction in the group irradiated by the Ho:YAG at the PMT (50mJ, 10 Hz, 66 J/cm 2 for 120 sec), followed by Ho:YAG irradiated at 50mJ, 10 Hz, 33 J/cm 2 for 60 sec, and the group that received calcium hydroxide. The latter two groups were not significantly different. The UV and VIS absorbance spectrum presented two absorbance peaks at 361nm and 337nm (UV). The NIR spectrum revealed a very low absorbance by the E. faecalis.

Page generated in 0.0627 seconds