• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Resistência de união de um cimento resinoso a diferentes superfícies de alumina densamente sinterizada / Shear bond strenght of a resin cement to different surfaces of densely sintered alumina

Valdivia, Juan Rommel Medina 20 June 2007 (has links)
O propósito deste estudo foi avaliar a resistência adesiva ao cisalhamento de um cimento resinoso à alumina densamente sinterizada testando o tratamento superficial feito pelo fabricante. O cimento utilizado foi o Multilink (Ivoclar Vivadent) e a alumina foi a Procera®Alumina (Nobel Biocare) constituída por 99,9 % de óxido de alumínio densamente sinterizado. Trinta e dois cilindros de alumina foram confeccionados pela Nobel Biocare, onde um dos extremos deste cilindro recebeu o tratamento superficial e o outro não. Para a aplicação do cimento resinoso sobre os cilindros de alumina, utilizou-se uma matriz de Teflon com um orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Foram determinados 4 grupos experimentais: Grupo 1 superfície sem tratamento; Grupo 2 superfície sem tratamento e com aplicação de adesivo; Grupo 3 - superfície com o tratamento realizado pelo fabricante; Grupo 4 superfície com tratamento realizado pelo fabricante e com adesivo. Após a aplicação do cimento nos 4 grupos, os espécimes foram armazenados em água deionizada a 37ºC durante 24h, sendo, em seguida, montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey para comparação entre os grupos. A superfície tratada (grupo 3) apresentou valores significativamente maiores que todos os outros grupos. A presença do adesivo diminuiu a resistência adesiva quando aplicado na superfície tratada, mas não deu diferença significante quando aplicado na superfície sem tratamento. / The aim of this study was to investigate the shear bond strength between a resin cement and densely sintered alumina treated by the fabricant. The resin cement used was the Multilink (Ivoclar Vivadent) and the alumina the Procera®Alumina (Nobel Biocare) made with 99,9% of densely sintered aluminum oxide. Thirty two alumina cylinders were made by Nobel Biocare, and in one of the extremes was applied a own`s fabricant surface treatment. For the application of the cement, a Teflon matrix with a central hole (diameter of 3,5 mm and a height of 3,0 mm) was used. Four groups were created: Group 1 surface without treatment; Group 2 - surface without treatment and with adhesive; Group 3 surface with the own`s fabricant treatment; Group 4 - surface with the own`s fabricant treatment with adhesive. After the cement application, the specimens were stored in water at 37º C for 24 hours. Then the samples were placed in a universal testing machine for making the shear strength test. Statistical analysis was performed with two-way analysis of variance (ANOVA), and paired comparisons between groups were done with Tukey`s multiple comparison. Higher significant values were detected for Group 3 when compared with all the other groups. The adhesive decreased the shear bond strength when laid on the treated surface, and there were no difference when laid on the untreated surface.
282

Avaliação dos efeitos do laser de Er,Cr:YSGG sobre superfícies radiculares expostas no tratamento da hipersensibilidade dentinária cervical. Estudo in vitro e in vivo / Desensitizing effects of Er:YAG and Er,Cr:YSGG lasers on dentin hypersensitivity. An in vitro and in vivo study

Aranha, Ana Cecilia Corrêa 03 August 2005 (has links)
O objetivo deste estudo foi o de avaliar os efeitos da irradiação laser de Er,Cr:YSGG em superfícies dentinárias no tratamento da hipersensibilidade dentinária cervical, em busca de um protocolo para ser aplicado clinicamente. Para o teste de permeabilidade, foram preparados 144 pré-molares, as coroas seccionadas e as raízes impermeabilizadas. Duas áreas de irradiação antagônicas foram delimitadas e livres da impermeabilização (controle e experimental). A seguir, os dentes foram subdivididos em dois sub-grupos, diferindo o condicionamento da superfície irradiada (EDTA 24% e ácido fosfórico 35%) e em grupos diferindo o protocolo:G1)Er:YAG, 60mJ/2Hz; G2)0,25W; G3)0,5W; G4)0,75W; G5)1W, G6)1,25W; G7)1,50W; G8)1,75W G9)2W. Após as irradiações, os espécimes foram imersos em azul de metileno 2% por 4 horas, e incluídos em resina epóxica para a realização dos cortes longitudinais. Estes tiveram suas imagens trabalhadas em computador para mensuração do nível de infiltração. Os dados foram submetidos à análise estatística. O Sub-grupo 1, condicionado com EDTA, apresentou diferenças entre os grupos sendo que as amostras irradiadas com Er:YAG demonstraram menor infiltração, diferindo estatisticamente dos grupos 3, 6 e 9. Os resultados do sub-grupo 2 mostraram que as médias das amostras irradiadas com Er:YAG tenderam a zero entretanto, não houve diferença entre os grupos. Na Fase B, fragmentos de dentina foram obtidos da região cervical de dentes humanos, preparados para análise em microscopia eletrônica de varredura. Morfologicamente, observou-se oclusão parcial dos túbulos dentinários após irradiação com Er:YAG e Er,Cr:YSGG nas condições de 0,25W e 0,50W. A partir de 0.75W, foi observado abertura dos túbulos e à medida que as energias aumentaram, foram observadas carbonização e fendas. De posse dos resultados dos trabalhos in vitro, foram selecionados os parâmetros para a aplicação e o acompanhamento clínico de 1 mês: G1)controle (placebo); G2)Er:YAG; G3)Er,Cr:YSGG 0,25W e G4)Er,Cr:YSGG 0,75W. Após a triagem, foram selecionados voluntários de acordo com critérios de exclusão e inclusão. O nível de sensibilidade de cada voluntário foi avaliado através da escala visual analógica de dor (VAS) com auxílio do ar da seringa tríplice 1 semana antes (Pré-1), 5 minutos anterior ao tratamento (Pré-2), após 5 minutos (Pós-1), 1 semana (Pós-2) e 1 mês após o tratamento (Pós-3). Os dados foram coletados e submetidos à análise estatística separadamente para os dois estímulos realizados: spray de ar e sonda exploradora. Tanto para o estímulo ar quanto para o estímulo sonda, não foram observadas diferenças estatisticamente significantes nas escalas Pré-1 e Pré-2, concluindo que os pacientes estavam padronizados e não houve efeito da profilaxia nos níveis de dor. Ao estímulo do spray de ar, nota-se uma redução nos níveis de dor na escala Pós-1, porém há uma estabilidade dos valores das escalas seguintes. O grupo 2 (Er:YAG) apresentou o menor nível de dor quando comparado aos outros grupos. Ao estímulo mecânico foi observado que o grupo 4 (Er,Cr:YSGG 0,50W) demonstrou o decréscimo de dor mais acentuado imediatamente após o tratamento, porém ao final do estudo, apresentou os maiores níveis de dor. Os grupos 1, 2 e 3 apresentam redução de dor, porém estatisticamente diferentes do grupo 4. Com base nos resultados apresentados e dentro dos limites e parâmetros estudados, pode-se concluir que nenhuma condição foi capaz de eliminar completamente a microinfiltração e diminuir a permeabilidade dentinária; porém o laser de Er:YAG e o laser de Er,Cr:YSGG 0,25W apresentaram resultados satisfatórios nos três estudos realizados. / The aim of the present study was to determine the correct parameters of the Er,Cr:YSGG laser in the treatment of cervical dentin hypersensitivity. This work was presented in 3 different stages. In the first one, it was evaluated the decrease in dentin permeability of dentinal tubules after Er,Cr:YSGG laser irradiation in radicular surfaces. Ninety premolars were prepared with its crows sectioned, and the roots completely impermeabilized. Two antagonist areas of irradiation were determined as control and experimental. Each surface was conditioned with EDTA 24% (sub-group1) and phosphoric acid 35% (sub-group2) and the selected parameters were: 1)Er:YAG, 60mJ, 2Hz, 4 irradiations of 20sec each, defocused mode; and groups 2 to 9 received irradiation with Er,Cr:YSGG laser, 20Hz, Z6 tip, 600µm diameter, defocus mode, 0% of air and water: 2)Er,Cr:YSGG 0,25W; 3) 0,5W; 4) 0,75W; 5) 1,0W; 6) 1,25W, 7) 1,50W, 8) 2W; 9) 2 W. After irradiation, samples were immersed in a solution of methylene blue for 4 hours, washed for 5 min and included in epoxy resin to allow longitudinal cuts. The images were digitalized and computed worked. Data was statistically analyzed. Although the samples irradiated with Er:YAG showed less microleakage, the sub-group 1 showed differences between the groups, statistically different from groups 3, 6 e 9. The results of the sub-group 2 showed that the mean values of the Er:YAG samples had a tendency to be negative, however, no differences were detected between the groups. In the second stage, cuts from the cervical area were obtained and prepared for scanning electron microscopy to evaluate the superficial morphology. It was observed the partial closure of dentinal tubules after the irradiation with Er:YAG and Er,Cr:YSGG laser in the 0.25 and 0.50W protocols. From the 0.75W until 2W, it was observed the dentinal tubules opened as the energy densities raised. With the results of the in vitro studies, the parameters were selected: G1)control; G2)Er:YAG; G3)Er,Cr:YSGG 0,25W e G4)Er,Cr:YSGG 0,75W. Thirty subjects, who met the entry criteria, were admitted into the study. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment as baseline (Pre-1), immediately before (Pre-2) and immediately after (Post-1) the topical treatment, after 1 week (Post-2) and after 1 month (Post-3). Teeth were assigned to the 4 groups. After the follow-up, data was collected and submitted to statistical analysis for both kinds of stimulus: evaporative (air) and mechanical (probe). For both air and probe it was not observed differences among the Pre-1 and Pre-2 moments, for what it can be concluded that patients were standardized. Analyzing the evaporative stimulus, it can be observed the reduction in the pain level immediately after the treatment; however there was stability in the next values. Group 2 (Er:YAG) showed the least level of pain. Throughout the mechanical stimulus, it was observed that group 4 (Er,Cr:YSGG 0,50W) showed the most pronounced decrease of pain immediately after treatment, however, at the end of the study, the levels of pain increased. Groups 1, 2 e 3 showed reduction of pain, statistically different from the group 4. Based on the results and within the limits of this study, it can be concluded that none of the parameters and lasers studied were capable of eliminate the microleakage and decrease the dentin permeability, however, the Er:YAG and Er,Cr:YSGG 0,25W lasers showed satisfactory results in the three studies performed.
283

Adaptação marginal de restaurações em resina composta expostas a diferentes agentes clareadores / Marginal adaptation of resin composite restorations exposed to bleaching agents

Abe, Andréa Tami 09 April 2018 (has links)
Este estudo teve como objetivo avaliar a adaptação marginal de restaurações em resina composta confeccionadas utilizando-se como agentes adesivos sistemas de diferentes estratégias de interação, expostas a agentes clareadores e submetidas a ciclagem mecânica, por meio de avaliação em tomografia por coerência óptica (OCT). Para este estudo foram utilizados 90 molares humanos hígidos recém-extraídos. Uma cavidade classe V foi confeccionada na face vestibular de cada dente com a margem oclusal localizada em esmalte e a margem cervical em cemento/ dentina. Os espécimes foram divididos em 3 grupos experimentais, de acordo com o sistema adesivo utilizado (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). As cavidades foram então preenchidas com a resina composta nanoparticulada Filtek Z350XT, e em seguida o acabamento e o polimento foram realizados. Os espécimes foram submetidos a duas ciclagens mecânicas, sendo a primeira antes e a segunda após o clareamento. Ao final da primeira ciclagem, os espécimes foram subdivididos em 3 grupos (n=10) de acordo com o tratamento realizado (controle - água destilada, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). As imagens em OCT das restaurações foram obtidas em 4 momentos diferentes (antes da primeira ciclagem, depois da primeira ciclagem, após o tratamento e depois da segunda ciclagem). A interface dente-restauração foi analisada de duas formas, por meio de classificação das fendas por escore e mensuração da profundidade da fenda em micrômetros (?m), para esmalte e dentina separadamente. Os valores de escore foram analisados com o teste estatístico não-paramétrico de Kruskal-Wallis (p<0.05), e para os dados de profundidade de fenda em ?m, a ANOVA dois fatores (p<0.05) e teste de Tukey foram empregados. A correlação de Spearman foi empregada para correlacionar esses dois dados e foi observada uma correlação forte entre os dados de escore e de profundidade em ?m (r=0.85 p<0.0001). A comparação entre os grupos, tanto por escores quanto por profundidade em ?m, demonstraram que as fendas observadas após a primeira ciclagem foram estatisticamente maiores (p<=0.05) do que as fendas observadas inicialmente, exceto para a análise por escores, onde essa diferença foi detectada apenas para o adesivo SB2. O adesivo SBU apresentou as menores fendas marginais tanto em esmalte quanto em dentina. Em esmalte o adesivo CSE mostrou-se mais estável à degradação e em dentina não foi observada diferença estatisticamente significante entre os adesivos CSE e SB2. Entre os diferentes tratamentos, nenhuma diferença foi observada, independente do tempo de análise e do adesivo utilizado. Pode-se concluir que os clareadores utilizados não promoveram alteração da integridade marginal das restaurações em resina composta, sendo que as fendas marginais observadas estão mais relacionadas ao efeito do envelhecimento por ciclagem mecânica e são dependentes do sistema adesivo utilizado. Foi observada correlação direta entre os dois métodos de análise para mensuração da fenda marginal, contudo a análise da profundidade em ?m, utilizando teste paramétrico, mostrou-se mais sensível para a detecção de diferenças. / The aim of this study was to evaluate the marginal adaptation of resin composite restorations using different dental adhesive systems, exposed to dental bleaching agents and mechanical load cycling, by evaluation using optical coherence tomography (OCT). For this study 90 sound recently extracted human molars were used. One class V cavity was prepared in the buccal surface of each tooth with occlusal margin in enamel and cervical margin in dentin. The specimens were divided into 3 experimental groups, according to the adhesive system used (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). The cavities were restored with the nanocomposite Filtek Z350XT, and then the finishing and polishing were done. The specimens were submitted to two mechanical load cycling, the first one before bleaching and the second one after it. By the end of the first load cycling, the specimens were subdivided into 3 groups (n=10) according to the treatment accomplished (control - distilled water, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). The OCT images of the restorations were obtained in 4 distinct moments (before the first load cycling, after the first load cycling, after the treatment, and after the second load cycling). The tooth-restoration interface was analyzed by two ways: analyzing the gap by score and measurement of the gap depth in micrometer (?m), for enamel and dentin separately. The scores were analyzed with the non-parametric statistic test Kruskal-Wallis (p<0.05), and for the gap depth data, the two-way ANOVA (p<0.05) and Tukey test were used. The Spearman correlation were done to correlate these two data and a strong correlation between the score analysis an depth in ?m was observed (r=0.85 p<0.0001). The comparison between the groups, as by score as by depth in ?m, demonstrated that the gaps observed after the first load cycling were statistically deeper (p<=0.05) than the gaps observed initially, except for score analysis, when this difference was detected only for the adhesive SB2. The adhesive SBU showed less deep marginal gaps both in enamel and dentin. In enamel, the adhesive CSE was more stable to degradation and in the dentin no statistically difference was observed between the adhesives CSE and SB2. Between the different treatments, no difference was observed, regardless the evaluation time and the dental adhesive used. In conclusion, the bleaching agents used in this study did not affect the marginal integrity of resin composite restorations, thus the marginal gaps observed were more related to the aging by mechanical load cycling and were dependent of the dental adhesive system used. There was a direct correlation between both methods for marginal gap analysis, however the depth in ?m analysis, using parametric statistical test, showed more sensitive to detect differences.
284

Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos / Effect of human saliva contamination on adhesive interface: bond strength, hybrid layer analysis and conversion of adhesive systems

Villavicencio Espinoza, Carlos Andres 03 July 2017 (has links)
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos. / The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
285

Perfilometria e microscopia eletrônica de varredura da superfície dentinária após escovação com cremes dentais dessensibilizantes e desafio erosivo com fruta amazônica / Profilometry and scanning electron microscopy of dentin surface after brushing with desensitizing toothpastes and challenge

Rocha, Max Pinto da Costa da 13 December 2012 (has links)
O objetivo deste estudo in vitro foi avaliar o potencial erosivo de suco de fruta amazônica ácida sobre a superfície dentinaria associado ao efeito abrasivo de diversos cremes dentais contendo agentes dessensibilizantes. O trabalho foi dividido em 3 fases distintas: Na fase 1, o valor do pH inicial de diversas frutas amazônicas foi medido utilizando 50 ml de cada suco, obtido de polpa industrializada. Foi utilizado um eletrodo de pH calibrado e a água destilada foi utilizada como controle. Na fase 2, 120 espécimes de dentina bovina foram submetidos a ciclos alternados de desafio abrasivo e erosivo, com a fruta escolhida na fase 1. Os espécimes foram divididos aleatoriamente em Grupo A (Desafio Abrasivo) e Grupo B (Desafio Erosivo e Abrasivo). Cada um destes grupos foram subdivididos em 5 subgrupos: 1: Água Destilada (Controle Negativo), 2: Colgate Tripla Ação (Controle Positivo), e os demais de acordo com o creme dental utilizado 3: Sensodyne Rápido Alívio, 4: Colgate Pró-Alivio e 5: Sensodyne Repair&Protect, (n=9). Na fase 3 foi realizado microscopia eletrônica de varredura para avaliar qualitativamente os espécimes (n=3). - O suco da fruta taperebá (Spondias mombin) apresentou os menores valores de pH, diante disso, foi escolhido como agente erosivo; Os testes de Kruskall Wallis e Teste de Dunn, mostraram que para os grupos nos quais somente a abrasão foi realizada, todos os cremes dentais mostraram comportamentos semelhantes em relação a perfilometria, não havendo diferença estatisticamente significante entre os grupos. Porém, para os grupos nos quais o processo erosivo foi adicionado, observou-se a potencialização do processo abrasivo, sendo que os cremes dentais Sensodyne Rápido Alivio e Colgate Sensitive Pro-Alivio foram os que mostraram menores alterações superficiais no padrão de perfilometria, comparados com o grupo controle negativo. Já os cremes dentais, Colgate Tripla Ação (controle positivo) e Sensodyne Repair&Protect apresentaram-se semelhantes entre si e com uma perda de estrutura dentinaria. mais significante. Conclui-se que o efeito erosivo da fruta amazônica taperebá é fator de grande importância na potencialização do efeito abrasivo, mesmo quando do uso de cremes dentais com agentes dessensibilizantes.. Na análise qualitativa da superfície dentinária em MEV, com exceção do Colgate tripla ação, os demais grupos não apresentaram oclusão tubular após o desafio ácido / The aim of this in vitro study was to evaluate the erosive potential of amazonian fruit juice with or without the abrasive challenge with various toothpastes containing desensitizing agents. The work was divided into three phases: in phase 1, the pH of various Amazonian fruits was evaluated. In step 2 it was performed surface perfilometry of the specimens, and in phase 3 it was evaluated qualitatively the dentin surface. In step 1, the initial pH value of several amazonian fruits was measured using 50 mL of each juice, from industrialized pulp. It was used a calibrated pH electrode, and distilled water was used as control. In step 2, 120 bovine dentin specimens were subjected to alternate cycles of abrasive and erosive challenge, with the fruit chosen in step 1. The specimens were randomly divided into Group A (without erosion) and Group B (with erosion). Each of these groups were divided into 5 groups: 1: Distilled Water, 2: Colgate Tripla Ação, 3: Sensodyne Rápido Alívio, 4: Pro-Alivio, 5: Sensodyne Repair & Protect, (n = 9). In Phase 3 it was conducted scanning electron microscopy to evaluate qualitatively the specimens (n=3). As a result it can be stated that: 1. The juice of the taperebá fruit had the lowest pH values, so it was chosen as the erosive agent; 2. For the groups in which only the abrasion was performed, all toothpastes showed similar behaviors, no statistically significant difference was observed between groups, but for the groups in which the erosion process was added, there was a potentiation of the abrasive process, and the toothpastes showed different profiles. The toothpaste Sensodyne Rapido Alívio Pró-Alívio was the ones that showed lower mineral loss, compared with the negative control group. Colgate Tripla Ação and Sensodyne Repair&Protect were similar among themselves and with a more significant mineral loss. It can be conclude that erosive effect of diet is a factor of great importance in the potentiation of abrasive effect. Clinical studies are essential to determine the dentin hypersensitivity levels after use of toothpaste used.
286

Avaliação da remoção de debris dentinários após diferentes métodos de irrigação final e sua influência na obturação do sistema de canais radiculares, utilizando a microtomografia computadorizada / Hard-tissue debris removal after different final irrigation methods and its influence on the filling of the root canal system, using micro-computed tomography

Freire, Laila Gonzales 03 June 2014 (has links)
A instrumentação do canal radicular possui como conseqüência a formação de debris dentinários, os quais acumulam-se especialmente nas áreas mais complexas do sistema de canais radiculares. Por este motivo, atenção especial tem sido concedida aos métodos de agitação da substâ ncia química auxiliar, com o intuito de melhorar a sua eficácia química e mecânica. No entanto, não está claro se debris dentinários removidos do interior do canal radicular possuem efeito na qualidade da obturação. Portanto, os objetivos deste estudo foram, com o auxílio da microtomografia computadorizada (micro-CT): avaliar e quantificar a presença de debris dentinários em canais curvos, após o preparo químico-cirúrgico; comparar a remoção desses debris, após uso de Irrigação Ultrassônica Passiva (IUP) ou do sistema EndoVac; e avaliar a qualidade da obturação dos mesmos canais, mensurando o volume de material obturador e de espaços vazios. Vinte e quatro raízes mesiais de molares inferiores humanos extraídos foram divididos aleatoriamente em 2 grupos (n=12), de acordo com o método de irrigação final a ser avaliado. Cada espécime foi submetido a quatro escaneamentos: exame préoperatório, exame pós-preparo, exame pós-irrigação final e exame pós-obturação, com um microtomógrafo de raios-X SkyScan 1176, a uma resolução de 17,42 m. Após preparo químico-cirúrgico os grupos receberam irrigação final com IUP ou com o sistema EndoVac e em seguida obturados com a técnica termoplástica de ondas contínuas de condensação. Após a reconstrução das imagens resultantes dos quatro escaneamentos, o corregistro das mesmas foi realizado com o programa DataViewer. Os programas CTAn e CTvol foram utilizados para binarização dos objetos de interesse, análise volumétrica e reconstrução de modelos 3D do canal radicular, dos debris dentinários e do material obturador. Os dados foram analisados estatisticamente com o programa GraphPad Prism por meio do teste t de Student (p < 0,05). As análises de micro-CT revelaram debris dentinários acumulados no interior dos canais radiculares, ocupando uma porcentagem média em relação ao volume do canal de 2,71% para o grupo IUP e 4,10% para o grupo EndoVac. Não houve diferença entre os grupos quanto à remoção de debris dentinários, nem em relação ao volume de material obturador e de espaços vazios (p > 0,05). Concluiu-se que a IUP e o sistema EndoVac foram igualmente eficientes na remoção de debris dentinários, reduzindo em média 50% do seu volume. Também, a ativação dos irrigantes pelos dois métodos não interferiu na qualidade da obturação do canal radicular. / Root canal preparation has as a consequence the formation of hard-tissue debris, which accumulates specially in the complex areas of the root canal system. For this reason, special attention has been given to methods of agitation of the irrigants, aiming to improve its chemical and mechanical efficiency. However, it is not clear if dentin debris removed from the root canal have impact on the quality of root canal filling. Therefore, the objectives of this study were, with the aid of microcomputed tomography (micro-CT): evaluate and quantify the presence of hard-tissue debris in curved root canals, after chemical-surgical preparation; compare the removal of such debris after final irrigation with Passive Ultrasonic Irrigation (PUI) or with the EndoVac system; and evaluate the quality of filling of the same root canals, measuring the volume of filling material and voids. Twenty-four mesial roots of extracted mandibular human molars were randomly divided into 2 groups (n = 12) according to the method of final irrigation being evaluated. Each specimen was subjected to four scans: preoperative, post-operative, post-final irrigation and post-filling, with a microcomputed tomography SkyScan 1176, at a resolution of 17,42 m. After chemosurgical preparation groups received final irrigation with Passive Ultrasonic Irrigation (PUI) or with EndoVac system and were then filled with the continuous wave condensation thermoplastic technique. After the reconstruction of the images resulted from the four scans, co-registration was performed with the DataViewer software. CTAn and CTvol softwares were used for binarization of the objects of interest, volumetric analysis and reconstruction of 3D models of the root canal, hardtissue debris and the filling material. Data were statistically analyzed with the GraphPad Prism program through t students test (p < 0,05). The analysis of micro- CT showed hard-tissue debris accumulated inside the root canal, occupying an average percentage of 2.71 % for the PUI group and 4.10 % for EndoVac group. There was no difference between the groups regarding the removal of hard-tissue debris, or in relation to the volume of filling material and voids (p > 0.05). It was concluded that the EndoVac and PUI were equally efficient in the removal of hardtissue debris, reducing an average of 50% of its volume. Also, irrigants activation with the two methods did not affect the quality of root canal filling.
287

Microtração de sistemas adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após preparo cavitário com laser de Er: YAG: avaliação in vitro / Microtensile bond strength of selfetch adhesive systems in demineralised dentin of primary teeth after Er: YAG laser irradiation: in vitro evaluation

Almeida, Cintia Guimaraes de 01 June 2011 (has links)
O objetivo deste estudo foi avaliar a resistência à microtração de adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após a irradiação com laser de Er: YAG. Oitenta e dois molares decíduos tiveram a porção oclusal seccionada transversalmente e os espécimes foram desgastados com lixas de carbeto de silício de granulações 360 e 600 até expor a dentina. Os 60 espécimes utilizados no teste de microtração foram preenchidos com resina composta fotopolimerizável na região correspondente à câmara pulpar, isolados com esmalte cosmético mantendo a superfície dentinária exposta e, em seguida imersos em solução desmineralizante por seis dias em estufa a 37&deg; C para indução de lesão de cárie artificial em dentina. Após a desmineralização, os espécimes foram preparados com laser de Er: YAG (n=30) com os parâmetros de 260 mJ, 3 Hz, 47 J/cm2, 0,81W e com broca de aço esférica em baixa rotação (n=30). Sobre as superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes Clearfil SE Bond (Kuraray); Adper&trade; Easy One (3M ESPE) e Adper&trade; SE Plus (3M ESPE) e, em seguida foram confeccionados platôs de resina composta Z 250. Após termociclagem (500 ciclos), os corpos de prova foram seccionados produzindo palitos de aproximadamente 1 mm2 de área transversal, que foram submetidos ao teste de microtração e os valores obtidos foram analisados estatisticamente através de ANOVA e teste de Duncan (5%). A análise qualitativa dos tipos de fraturas foi realizada por meio de lupa estereoscópica (aumento de 40X) e da interface adesiva por meio de MEV. Para a análise química da dentina através de espectroscopia no infravermelho por transformada de Fourier (FTIR), foram utilizados discos de dentina após o preparo superficial com a broca (n=5) e com o laser (n=5), e comparadas com as análises de tecido dentinário sadio e desmineralizado obtidas dos mesmos espécimes. Os resultados foram submetidos ao teste estatístico t&minus;Student (5%). O teste de microtração demonstrou que houve diferença significativa entre os adesivos, sendo que o grupo controle (Clearfil e broca) obteve o melhor desempenho comparativamente a todos os grupos avaliados. O preparo com laser de Er: YAG afetou adversamente a adesão para os sistemas adesivos Clearfil SE Bond e Adper&trade; Easy One em comparação com os grupos preparados com broca. Nos grupos irradiados com laser, o sistema adesivo Clearfil SE Bond foi o que proporcionou o maior valor médio de microtração. Os resultados da FTIR demonstraram que, com a irradiação da dentina desmineralizada, houve um decréscimo na quantidade de matéria orgânica e de carbonato em relação ao grupo da dentina sadia. No substrato preparado com broca, observouse aumento da matéria orgânica e redução de carbonato. Concluise que, em relação aos sistemas adesivos, o Clearfil SE Bond teve o melhor desempenho no teste de resistência à microtração em dentina de dentes decíduos. A irradiação com laser de Er: YAG afetou adversamente a adesão dos sistemas adesivos Clearfil SE Bond e Adper&trade; Easy One. A irradiação com laser de Er:YAG decresceu de maneira significativa a quantidade de matéria orgânica presente na dentina de dentes decíduos. / The purpose of this study was to evaluate the microtensile bond strength of three selfetch adhesives systems to demineralized dentin of primary teeth after irradiation with Er: YAG laser. Eighty two primary molars had the occlusal enamel sectioned and the specimens were grounded with silicon carbide sandpaper grits of 360 and 600 to expose the dentin. The 60 specimens used in the microtensile test were filled with composite resin in the region corresponding to the pulp chamber, insulated with nail varnish keeping the exposed dentin surface and then immersed in demineralizing solution for six days in a stove at 37 Celsius degrees in order to produce artificial carieslike lesions in dentin. After demineralization, the specimens were prepared with Er: YAG (n = 30) using as parameters 260 mJ, 3 Hz, 47 J/cm2, 0.81 W and a round steel drill at low speed (n = 30 ). On the prepared surfaces were applied three self&minus;etch adhesives systems Clearfil SE Bond (Kuraray); Adper&trade; Easy One (3M ESPE) and AdperTM SE Plus (3M ESPE) and then plateaus of composite resin Z 250 were built up. After thermocycling (500 cycles), specimens were sectioned to produce multiple sticks of approximately 1 mm2 crosssectional area, which were subjected to microtensile test and the data were analyzed with ANOVA and Duncan test at a significance level of 0.05. The qualitative analysis of the types of fractures was performed using a stereomicroscope (X40 magnification) and the morphological analyses of adhesive interfaces were performed by scanning electron microscopy (SEM). Chemical analysis of the dentin by Fourier transform infrared spectroscopy (FTIR) were performed in dentin discs after surface preparation with the steel drill (n = 5) and laser (n = 5) and compared with the values previously obtained from the analysis of sound and demineralized dentin tissue in the same specimens. The results were analyzed by Student\'s t&minus;test at a significance level of 0.05. Regarding the microtensile bond strength there was a significant difference between the adhesive systems, and the control group (Clearfil and steel drill) had the best performance compared to all groups. Er: YAG laser irradiation adversely affected bond strength to the Clearfil SE Bond and Adper&trade; Easy One compared with the groups prepared with steel drill. In the laser groups Clearfil SE Bond reached the highest average bond strength. Results of FTIR analysis showed that the hydration of dentin remained normal after both preparations. With laser irradiation of demineralized dentin there was a decrease in the amount of organic matter and carbonate in relation to the group of sound dentin. The analyses of substrate prepared with steel drill showed an increase in organic matter and reduction of carbonate. The conclusion in relation to adhesive systems was that Clearfil SE Bond had the best performance in microtensile bond strength in primary teeth dentin. Laser irradiation adversely affected the bond strength of Clearfil SE Bond and Adper&trade; Easy One selfetch adhesive systems. Laser irradiation had significantly reduced the organic matter content in dentin of deciduous teeth.
288

"Resposta de fibroblastos de polpa humanos submetidos a substâncias liberadas por capeadores pulpares diretos" / Human pulp fibroblasts response to substances leached from direct pulp capping materials

Cavalcanti, Bruno das Neves 04 February 2004 (has links)
Cavalcanti, BN. Resposta de fibroblastos de polpa humanos frente a substâncias liberadas por capeadores pulpares diretos [Tese de Doutorado]. São Paulo: Faculdade de Odontologia da USP; 2003. RESUMO O objetivo do presente estudo foi o de avaliar os efeitos citotóxicos de substâncias liberadas durante a aplicação de materiais utilizados em capeamento pulpar direto, sobre fibroblastos de polpa dentária humana. Utilizou-se para o experimento meios condicionados pelas substâncias a serem testadas, divididas nos grupos a seguir: grupo I: controle (meio de cultivo sem condicionamento); grupo II: cimento de hidróxido de cálcio; grupo III: adesivo dentinário; grupo IV: ácido ortofosfórico a 37%. O condicionamento foi realizado, colocando-se meio de cultivo fresco sobre os materiais de modo que a presa (grupo II), polimerização (grupo III) ou o contato direto (grupo IV) liberassem substâncias para esse meio de cultivo. Esse meio era colocado sobre as células durante todo o experimento, excetuando-se o grupo IV, onde o contato foi feito por um período de 15 segundos, conforme recomendações clínicas. Posteriormente foram realizadas contagens em hemocitômetro pelo método de exclusão por azul de Trypan, que cora somente as células mortas. As contagens foram realizadas em períodos de 0, 6, 12 e 24 horas para o experimento de viabilidade celular (curto prazo), onde se avaliou o percentual de células vivas sobre o total de células, e em períodos de 1, 3, 5 e 7 dias para o experimento de sobrevivência celular, no qual se avaliou o número absoluto de células vivas. Observou-se que as substâncias liberadas pelo adesivo dentinário são citotóxicas em qualquer período, diminuindo consideravelmente a viabilidade celular e afetando suas curvas de crescimento. Aquelas liberadas pelo ácido ortofosfórico a 37% provocam diminuição da viabilidade somente nos primeiros momentos do contato com as células, enquanto as substâncias liberadas durante a presa do hidróxido de cálcio não são citotóxicas em nenhum momento. / The purpose of the present study was to evaluate the cytotoxic effects of substances leached during the use of direct pulp capping materials, on human pulp fibroblasts. There were used cell culture mediums conditioned by the test materials, as follows: group I: control (fresh medium without conditioning); group II: calcium hydroxide cement; group III: bonding system; group IV: 37% orthophosphoric acid. The medium conditioning was made, pouring the fresh conditioning medium on the materials, in order that its setting (group II), polymerization (group III) or the direct contact (group IV) would be able to leach substances to this culture medium. These conditioned mediums were put on the cells for the entire experiment, excepting the group IV, in which the mediums were put in contact with the cells for 15 seconds, following clinical recommendations. Cell counting was performed in hemocytometer, using the Trypan blue exclusion method, which mark only the dead cells. These counting was made at experimental times of 0, 6, 12 and 24 hours for the cell viability assay (short term), where it is evaluated the percentage of live cells on the total number of cells, and at experimental times of 1, 3, 5 and 7 days for the survival assay, in which is evaluated the absolute number of live cells. It was observed that the substances leached by the bonding system are cytotoxic at all experimental times, decreasing significantly the cell viability and affecting its growing rate. Those leached by the 37% orthophosphoric acid decreased the cell viability only at the first contact with the cells, and the substances leached during the setting of the calcium hydroxide cement are not cytotoxic.
289

ALTERNATIVAS PARA MELHORAR AS PROPRIEDADES ADESIVAS DE SISTEMAS ADESIVOS UNIVERSAIS EM DENTINA EROSIONADA / Alternatives to improve the adhesive properties of universal adhesive systems in eroded dentin

Siqueira, Fabiana Suelen Figueredo de 07 April 2017 (has links)
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 FABIANA SIQUEIRA.pdf: 4384235 bytes, checksum: 655ceab1a73a43f410cdb4b5e3773475 (MD5) Previous issue date: 2017-04-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of the present study was evaluate the adhesive properties of eroded dentin with different pH cycling using universal adhesive systems and to evaluate the application of collagen cross-linking agent or MMP inhibitors on the resin-eroded dentin interface, through of three in vitro studies. For the experiment 1, the teeth were randomly assigned into the experimental groups according to the combination of variables: dentin surface (sound dentin and eroded dentin) vs adhesive systems (10 universal adhesives) vs Adhesive strategy [etch-and-rinse (ER) and self-etch (SE)]. The adhesive systems were applied according to the manufacturer's instructions and the teeth were restored. They were sectioned to analysis of microtensile bond strength (μTBS) and nanoleakage (NL). The surfaces of 2 tooth were examined under scanning electron microscopy (SEM) to evaluate the surface characterization after erosive-cycling. For experiment 2, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded dentin with citric acid pH 2.3) vs. adhesive systems [Prime & Bond Elect (PBE); Scotchbond Universal Adhesive (SBU); Tetric N-Bond Universal (TEU)] vs Treatment agents [6.5% primer containing proanthocyanidin (PA) and 0.1% riboflavin (RI)]. The surface was treated with primers and the adhesive systems were applied and restored. The samples were sectioned and tested for μTBS, NL and degree of conversion (DC). The surfaces of 2 tooth were examined under SEM to evaluate the surface characterization after erosive-cycling. For experiment 3, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded eroded with citric acid pH 2.3) vs. Adhesive Systems (PBE; SBU; TEU) vs Acid pretreatment [control with 37% phosphoric acid;Phosphoric acid containing 2% chlorhexidine (CHXacid) and phosphoric acid containing 3% PA (PAacid)]. The teeth were acid-etched according to each experimental conditions, the adhesive systems were applied and the teeth were restored. The teeth were sectioned and tested for μTBS, NL and DC. Data were submitted to appropriate statistical analysis (α = 0.05). The μTBS values in eroded dentin were statistically lower than sound dentin, independent of the adhesive strategy (p < 0.01) The inclusion of primers containing collagen cross-linking agents in the eroded dentin adhesive protocol improved μTBS values (p <0.001),significantly reduced NL (p <0.004) for all the adhesives tested, as well as improved DC (p <0.03). The use of phosphoric acids containing MMPs inhibitors or collagen cross-linking agent improved μTBS values (p> 0.33), produced a significant reduction of NL (p <0.004) and improved DC (p <0.03). The application of MMP inhibitors (primer or acid etching - containing) were effective to improve the properties of the resin-eroded dentin interface. / O objetivo desse estudo foi avaliar as propriedades adesivas à dentina erosionada utilizando sistemas adesivos universais e verificar o efeito da aplicação de agentes reticuladores de colágeno ou inibidores de Metaloproteinases (MMPs) na interface resina-dentina erosionada, através de três estudos laboratoriais. Para o experimento 1, os dentes foram distribuídos aleatoriamente entre os grupos experimentais de acordo com a combinação das variáveis: superfície dentinária (controle sem erosão e erosionada) vs. sistemas adesivos (10 sistemas adesivos universais) vs.estratégia adesiva [condicionamento convencional (ER) e autocondicionante (SE)].Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante e os dentes foram restaurados. Depois foram seccionados para análise da resistência de união à dentina (μTBS) e nanoinfiltração (NI). A superfície de 2 dentes foi examinada sob microscopia eletrônica de varredura (MEV) para avaliar as características da superfície após ciclagem erosiva. Para o experimento 2, os dentes foram aleatoriamente alocados em 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos [Prime & Bond Elect (PBE), Scotchbond Universal Adhesive (SBU) e Tetric N-Bond Universal (TEU)] vs. Agentes de tratamento [primer contendo 6,5% de roantocianidina (PA) e primer contendo 0,1% de riboflavina (RI)]. Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante após aplicação do primer e restaurados. A seguir, os dentes foram seccionados e testados para análise da μTBS, NI e grau de conversão (GC). A superfície de 2 dentes foi examinada sob MEV para avaliar as características da superfície após erosão. Para o experimento 3, os dentes foram alocados aleatoriamente dentro de 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos (PBE, SBU e TEU) vs. pré-tratamento ácido [controle com ácido fosfórico 37%; Ácido fosfórico contendo 2% de clorexidina (CHXacido) e ácido fosfórico contendo 3% de PA (PAacido)]. Os dentes foram condicionados de acordo com cada grupo experimental, os sistemas adesivos foram aplicados e restaurados com resina composta. Posteriormente, os dentes foram seccionados e testados para análise da μTBS, NI e GC. Todos os dados foram submetidos a ANOVA 3 fatores e teste de Tukey (α = 0,05). Os valores de μTBS em dentina erosionada foi estatisticamente inferior à dentina sadia,independente da estratégia adesiva (p > 0,61). A inclusão de primers contendo agentes reticuladores de colágeno no protocolo adesivo a dentina erosionada,melhorou os valores de μTBS (p < 0,001), diminuiu significativamente a NI (p <0,004) para os adesivos testados, além de melhorar o GC (p < 0,03). A utilização de ácidos fosfórico contendo inibidores de MMPs ou agentes reticuladores de colágeno melhorou os valores de μTBS (p > 0,33), produziu uma redução significativa da NI (p < 0,004) e melhorou o GC (p < 0,03). Os agentes reticuladores independente do veículo (primer ou condicionamento ácido) foram eficazes para melhorar as propriedades da interface resina-dentina erosionada.
290

INFLUÊNCIA DA APLICAÇÃO ULTRASSÔNICA EM DIFERENTES SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO AO CANAL RADICULAR / Effect of ultrasonic application of different adhesive systems on the adhesion of glass fiber posts to root canal

Escobar, Carolina Gealh Navarro 18 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:06Z (GMT). No. of bitstreams: 1 Carolina Navarro Escobar.pdf: 2962199 bytes, checksum: b363e18fe311073f074dad7842063d6b (MD5) Previous issue date: 2016-02-18 / The aim of this study was evaluate the influence of the aplication mode of adhesive systems on the push-out bond strenght (POBS), silver nitrate uptake (SNU) and in situ degree of conversion (ISDC) on the hibrid layer after cementation luted posts.The roots of 66 human premolars were prepared and divided in six groups (n=11), according to the following combination: application mode (manual passive, manual active and ultrassonic vibration) and etch and rinse and self-etch adhesive systems (Adper Single Bond 2 and Single Bond Universal). The posts were cemented in accordance with the manufacturer’s instructions of each cementation system. After one week of water storage, the roots were seccioned transversely into six slabs and were tasted in POBS (0.5mm/min). Two roots for group were data immersed in 50% silver nitrate, photo-developed and analyzed by SEM to measure the SNU. Two roots for group were evaluated by micro-Raman spectroscopy to measure ISDC. The data were analyzed by 3-way repeated measures ANOVA and Tukey´s tests (5%). With the results obtained, it was observed: bond strength increased with the use of active application (manual and ultrasonic) of the adhesive. Using adhesive system Adper Single Bond the nitrate leakage values increase but with ultrasound prototype the nitrate leakage values reduce in relation active application. In ISDC a significant increase in the cervical and middle thirds with active application was observed and all thirds using ultrasound prototype, the passive application using Single Bond Universal adhesive showed worse results. / O objetivo deste estudo foi avaliar o efeito do modo de aplicação de sistemas adesivos nos valores de resistência de união (RU), nanoinfiltração (NI) e grau de conversão (GC) da camada híbrida após a cimentação dos pinos no interior do conduto radicular. Canais de 66 pré-molares unirradiculares foram tratados endodônticamente, e foram aleatoriamente divididos em seis grupos (n=11) de acordo com a combinação da técnica de aplicação adesiva (manual passiva, manual ativa e aplicação vibratória com um dispositivo ultrassônico) e dos sistemas adesivos com seus respectivos cimentos resinosos (Sistema Adesivo Adper Single Bond 2 com RelyX ARC e Single Bond Universal e RelyX Ultimate [3M ESPE]). Após uma semana dos procedimentos de cimentação, cada raiz foi seccionada transversalmente em seis discos com 1 mm de espessura cada, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular identificados. Sete raízes por grupo (n=7) foram submetidas ao teste de push-out para avaliação da RU, a uma velocidade de 0,5 mm/min. Duas raízes por grupo (n=2) foram imersas em 50% de nitrato de prata, e após revelação, foram analisadas por MEV para avaliação da NI, e os corpos de prova das duas raízes restantes de cada grupo (n=2) foram avaliadas por espectroscopia de micro-Raman para medir GC. Os dados de RU, NI e GC foram analisados por análise de variância de 3 fatores de medidas repetidas (terço radicular) e teste de Tukey (5%). Com os resultados obtidos, foi observado: aumento de resistência de união com a utilização da aplicação ativa (manual e utrassônica) do adesivo. Maiores valores de infiltração de nitrato utilizando o sistema adesivo Adper Single Bond, uma redução dos valores de infiltração de nitrato utilizando o protótipo de ultrassom em relação aplicação ativa. No teste de grau de conversão foi observado um aumento significativo de GC nos terços cervical e médio com a utilização da aplicação ativa e em todos os terços utilizando o protótipo de ultrassom, na aplicação passiva utilizando o adesivo Single Bond Universal foram obtidos os piores resultados.

Page generated in 0.0488 seconds