• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

"Estudo da morfologia da interface de união em diferentes regiões de uma cavidade MOD" / A morphological study of the bonding interface in different areas of MOD cavities.

Sandra Kiss Moura 12 June 2003 (has links)
RESUMO Esmalte e dentina são substratos dentários simultaneamente presentes na maioria das cavidades preparadas para restaurações adesivas, mas não há estudos sobre a morfologia regional das interfaces de união em uma mesma cavidade. Adesivos autocondicionantes incorporam a smear layer na camada híbrida e, conseqüentemente, as bactérias que porventura estejam presentes nela. Recentemente surgiu um adesivo autocondicionante com propriedades antibacterianas, conferidas pela adição de MDPB ao primer, mas ainda há poucas pesquisas sobre a morfologia da interface de união produzida por este material. Este estudo teve por objetivo analisar a morfologia de interfaces de união em diferentes regiões de cavidades MOD, através de microscopia eletrônica de varredura - MEV, em casos com adesivos autocondicionantes com ou sem MDPB. Como controle, foram usados dois adesivos de frasco único, cuja morfologia está amplamente descrita na literatura. Foram preparadas dezesseis cavidades Classe II em terceiros molares humanos hígidos, que foram restauradas com Z250 e um dos seguintes sistemas adesivos, aplicados segundo instruções dos fabricantes: ABF, Clearfil SE Bond, Single Bond e Prime & Bond NT. Após vinte e quatro horas de armazenamento em água destilada a 37ºC, os dentes restaurados foram seccionados em três planos de corte e preparados para análise em MEV, segundo o protocolo descrito por Montes et al. (2001). Também foram preparadas réplicas dos espécimes em resina epóxica. A morfologia das interfaces de união apresentou diferenças dependendo da região observada e também do tipo de sistema adesivo. A presença de MDPB não alterou a morfologia da interface de união dos adesivos autocondicionantes. A morfologia das interfaces de união em esmalte revelou perfeita adaptação ao substrato para todos os produtos estudados. / ABSTRACT Enamel and dentin are dental substrates simultaneously present in most cavity preparations for bonded restorations. Yet, no study can be found regarding the regional morphology of bonding interfaces present in a same cavity. Self-etching adhesive systems incorporate the smear layer into the formed hybrid layer, and consequently bacteria that might be present. Recently a self-etching system with antibacterial properties provided by the addition of MDPB was introduced in the market, but there is still little research on the interfacial morphology obtained with this material. This study aimed at analyzing the interfacial morphology in different areas of MOD cavities prepared using adhesive systems either with or without MDPB, by means of Scanning Electron Microscopy – SEM. Two single bottle adhesive systems whose morphology is widely described in the literature were used as control groups. Sixteen class II cavities were cut in sound human molars and restores using Z250 resin composite and one of the following adhesive systems, applied strictly according to the manufacturers’ instructions: ABF, Clearfil SE Bond, Single Bond and Prime & Bond NT. After 24-hour storage in distilled water at 37ºC, the teeth were sectioned in three directions and prepared for SEM analysis according to the protocol described by Montes et al. (2001). Replicas were also obtained from each specimen using epoxy resin. The interfacial morphology showed differences depending on the observed area, and also on the adhesive system. The presence of MDPB did not alter the interfacial morphology of the bonded interfaces obtained with self-etching adhesive systems. Bonded interfaces in enamel revealed perfect adaptation for all studied materials.
272

"Aspectos de micromorfologia, resistência de união e adaptação à dentina em função do tipo de adesivo e das características da camada de esfregaço" / Micromorphological aspects, bond strength and adaptation to dentin as a function of the type of the adhesive and the smear layer characteristics

Silvia Kenshima 07 December 2005 (has links)
O objetivo do estudo foi avaliar o efeito de adesivos autocondicionantes com diferentes pHs aplicados em camadas de esfregaço (CE) fina e espessa na sua resistência de união (RU), adaptação marginal (AM) e micromorfologia. Foram utilizados 47 molares (n=5). A dentina oclusal foi exposta e cada dente foi seccionado em duas metades (unidade experimental) preparadas com lixa 600 (CE fina) e 60 (CE espessa). Os sistemas autocondicionantes foram selecionados conforme a acidez: Clearfil SE Bond (SE- fraco), Optibond Solo primer e adesivo (SO-intermediário), TYrian + One Step Plus (TY–forte). Um sistema convencional, ScotchBond Multi-Uso (MP) também foi estudado. A aplicação dos adesivos foi aleatória e uma reconstrução da porção coronária foi realizada com resina Z-250. Após 24h, os palitos para microtração (0,8mm 2 ) foram preparados. Parte deles foi submetida à microtração (Kratos–0,5mm/min). (Um índice de RU foi calculado levando-se em consideração a contribuição relativa dos tipos de fratura ocorridos). A outra parte foi avaliada em microscopia de luz (400x) quanto à AM tendo sido calculada a largura média de fendas (Lm) na interface de união. Para observação do padrão de condicionamento por MEV, os primers autocondicionantes e o H3PO4 foram aplicados à dentina tratada com lixa 60 e 600, removidos com banhos de álcool e acetona, fixados, desidratados com etanol, secos com HMDS e recobertos com ouro. Para observação dos prolongamentos resinosos, unidades experimentais “restauradas” com Z-250 tiveram a dentina removida com HCl e NaHOCl e as amostras recobertas com ouro. Os dados de RU e AM foram submetidos a ANOVA de 2 fatores (p=0,05). Testes de regressão (p=0,05) foram aplicados para RU e Lm e de cada um com o pH dos primers autocondicionantes. Apenas o fator Adesivo foi significante para RU e Lm e não houve relação entre ambos. Observou-se que TY apresentou RU significativamente inferior aos demais sistemas, semelhantes entre si. A Lm foi tanto maior quanto menor a acidez do sistema autocondicionante e MP apresentou a menor Lm. Em condições de CE espessa, as Lm foram significativamente maiores. Notou-se que o sistema de acidez fraca foi o mais afetado pela CE espessa tanto no padrão de condicionamento como na formação de prolongamentos resinosos. Houve maior remoção da CE com o sistema de acidez forte. Concluiu-se que, nas condições experimentais testadas, apenas o sistema convencional conseguiu aliar altos valores de resistência de união a uma boa adaptação marginal, e ainda reunir aspectos de micromorfologia compatíveis / The objective of this study was to evaluate the effect of different pH self-etch adhesives applied to thick and thin smear layer (SL) on bond strength (BS), marginal adaptation (MA) and micromorphology. 47 molars (n=5) were used. The occlusal dentin was exposed and each tooth was sectioned in two halves (experimental unit) prepared with 600-grit SiC paper (thin SL) and 60-grit (thick SL). The self-etch adhesives were selected according to the acidity: Clearfil SE Bond (SE-mild), Optibond Solo primer and adhesive (SO-intermediary), Tyrian + One Step Plus (TY– strong). An etch-&-rinse system, ScotchBond Multi-Purpose (MP) was also studied. The adhesives application was randomized and a resin composite build-up was made with Z-250. After 24h, the microtensile sticks (0.8 mm2) were prepared. Part of them was submitted to the microtensile bond strength test (Kratos-0.5 mm/min). (A BS index was calculated considering the relative contribution of the fracture types observed in the fractured sticks). The other part had the MA evaluated by light microscopy (400x) for the mean interfacial gap width (Gw) calculation. For the conditioning pattern SEM evaluation, the self-etch primers and the phosphoric acid was applied to dentin (60 and 600-grit), removed with baths of alcohol and acetone, fixed, dehydrated with ethanol, dried with HMDS and gold sputtered. For resin tags observation, restored experimental units were used. The dentin was removed with HCl and NaHOCl and gold sputtered. The BS and MA data was analyzed by 2-way ANOVA (p=0.05). The regression test (p=0.05) was performed for BS and Gw and for both with the self-etch primers pH. A regression test was applied for Gw and Li to evaluate their relationship (p=0.05). Only the Adhesive was significant for BS and Gw and no there was no relationship for them. TY presented significantly lower BS compared to the other adhesives that had similar BS. The higher the pH of the self-etch primers, the larger were the corresponding Gw (Gw x pH regression was significant). MP presented the lowest Gw. With thick SL, the Gw was significantly larger. The mild self-etch adhesive was affected by the thick SL in both the conditioning pattern and tags formation. The SL removal was more extensive with the strong self-etch. It was concluded that only the etch-&-rinse system achieved high BS and good MA with compatible micromorphological aspects
273

Avaliação da resistência da união de sistemas adesivos após a aplicação de agentes dessensibilizantes em dentina humana / Bond strength evaluation of the adhesive systems after desensitizer agents in human dentin

Teixeira, Vitória Celeste Fernandes 08 July 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T13:13:18Z No. of bitstreams: 1 vitoriacelestefernandesteixeira.pdf: 5962558 bytes, checksum: 288c2013154e288680445ffcde39df0c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:54:59Z (GMT) No. of bitstreams: 1 vitoriacelestefernandesteixeira.pdf: 5962558 bytes, checksum: 288c2013154e288680445ffcde39df0c (MD5) / Made available in DSpace on 2016-07-13T16:54:59Z (GMT). No. of bitstreams: 1 vitoriacelestefernandesteixeira.pdf: 5962558 bytes, checksum: 288c2013154e288680445ffcde39df0c (MD5) Previous issue date: 2011-07-08 / O objetivo do presente estudo foi avaliar a resistência da união à microtração dos sistemas adesivos convencional (Single Bond II, SB) e autocondicionante (Clearfil SE Bond, SE) em dentina humana condicionada após a aplicação de agentes dessensibilizantes. Foram utilizados discos obtidos de terceiros molares humanos hígidos, os quais tiveram o esmalte oclusal removido para exposição de superfícies planas de dentina média. Seis grupos foram formados, de acordo com os materiais utilizados: G1 (controle) – hibridização com SB; G2 - dessensibilizante à base de oxalato (BisBlock, BB) e SB; G3 - dessensibilizante à base de fluoreto (Aqua Prep F, AF) e SB; G4 (controle) – hibridização com SE; G5 – BB e SE; G6 – AF e SE. Sobre estas superfícies foram confeccionados blocos de resina composta Filtek Z350 de 5 mm de altura para obtenção de palitos de 1Ox1x1mm. Os corpos de prova foram armazenados em água deionizada a 37° por 24h e submetidos ao ensaio mecânico de microtração com velocidade de 1mm/min até a fratura. Os resultados foram analisados através de ANOVA two-way e Teste Tukey (p<0,05). Os valores médios dos grupos em MPa foram: G2 46,48 (8,04), G3 44,87 (11,26), G5 39,02 (13,45), G4 36,95 (7,14), G1 36,66 (10,84) e G6 32,71 (13,83) os quais não exibiram diferença estatisticamente significativa entre si (p=0,012). Conclui-se que o uso combinado de dessensibilizantes aos sistemas adesivos convencional e autocondicionante sobre a dentina humana condicionada não alterou a resistência da união. / The aim of study was evaluate the microtensile bond strength of the total etch (Single Bond II, SB) and self-etch adhesive systems (Clearfil SE Bond, SE) in human dentin after desensitizer agents. Disks were obtained from human third molars, which had their oclusal enamel removed to expose flat dentin surface. Six groups were formed according to the materials used: G1 (control)- hybridization with SB, G2- oxalate desensitizer (BisBlock, BB) and SB, G3- fluoride desensitizer (Aqua Prep F, AF) and SB, G4 (control)- hybridization with SE, G5- BB and SE, G6- AF and SE. On these surfaces were made blocks of composite Filtek Z350 of 5 mm to obtain “sticks” 10x1x1 mm. The specimens were stored in deionized water at 37°/ 24 h and subjected to microtensile testing 1 mm/min until fracture. The images were observed in MEV. The results were analyzed ANOVA two-way and Tukey test (p<0,05). The mean values of the groups in MPa were: G2- 46.48(8.04), G3- 44.87(11.26), G5- 39.02 (13.45), G4-36.95(7.14), G1- 36.66(10.84) and G6- 32.71(13.83) which showed no statistically significant difference between groups (p =0.012). It can be concluded that the combined use the desensitizers and adhesive systems in human dentin etched there is no influence on bond strength.
274

Efeito da contaminação por primer e pelo excesso de água, álcool ou clorexidina nas propriedades mecânicas e cinética de conversão de sistemas adesivos convencionais / Effect of contamination by primer and the water, ethanol or chlorexidine excess on mechanical properties and real time conversion of conventional adhesives systems

Humel, Maria Malerba Colombi, 1983- 21 August 2018 (has links)
Orientador: Luís Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:44:51Z (GMT). No. of bitstreams: 1 Humel_MariaMalerbaColombi_D.pdf: 11561780 bytes, checksum: 79e3ed8605dc03bf07a59b8bb75596c5 (MD5) Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência de diferentes concentrações destas soluções na resistência à flexão (FS), módulo de Elasticidade (E) e grau de conversão (DC) de sistemas adesivos convencionais, e ainda, sua influência na cinética (K) e taxa de conversão (RP). Para isso foram realizados dois trabalhos experimentais, sendo que no primeiro avaliaram-se as quantidades de primer nos adesivos, e no segundo trabalho avaliou-se a influência das soluções de enxague de cavidade, água, EtOH e CHX, quando em excesso, nos sistemas adesivos. Para se avaliar as diferentes concentrações do primer residual dois adesivos foram manipulados, M1 e M2 e testados com quatro concentrações de primer: 0, 5, 10 e 15%. Já para se avaliar o excesso de água, EtOH e CHX, dois adesivos foram testados: M1, adesivo manipulado, e o adesivo comercial SBMP; diluídos com 0, 2 e 9% para cada uma das soluções. Para se avaliar as propriedades mecânicas, nos dois estudos, foram preparadas amostras a partir de moldes de silicone em forma de barras (7 x 2 x 1mm) e após armazenamento por 24h, foram testadas em máquina de ensaio mecânico para o teste de FS a uma velocidade de 0,5 mm/min. DC foi mensurado utilizando Espectroscopia Transformada Infravermelha de Fourier (FTIR). Para cinética de conversão, a polimerização em cada diluição foi monitorada por FTIR pelo tempo de 60s, sendo que a conversão foi calculada a cada dois 2s de polimerização, avaliando-se também RP. No primeiro estudo, as diferentes concentrações da diluição com primer não mostrou diferença no teste de FS entre os adesivos testados, independente da concentração avaliada. Os dois adesivos testados apresentaram redução nos valores de DC com o aumento das quantidades de primer, sendo o adesivo M2 o mais susceptível às diluições. No segundo trabalho, para as diluições com água, EtOH, independente da quantidade testada, uma redução nas propriedades mecânicas e DC puderam ser observadas. As diluições em água e CHX alteraram mais as propriedades mecânicas quando comparadas as diluições com EtOH. Para K e RP com o aumento da concentração de primer residual todos adesivos apresentaram redução quando se avaliou os gráficos de conversão. Para as diluições em água, o aumento de sua concentração levou a queda progressiva na K e as diluições com CHX apresentaram menor influência na K, com redução apenas para 9% de diluição. Porém, para as diluições em EtOH houve aumento na K e RP especialmente para o adesivo SBMP. Assim, para o primeiro estudo, os resultados sugerem que as diferentes quantidades de primer usadas na diluição do adesivo não influenciam as propriedades mecânicas dos adesivos testados, porém, interferem na sua reação química de polimerização, uma vez que a velocidade reação foi reduzida (K e RP). Por outro lado, no segundo estudo, para as soluções residuais de água, EtOH e CHX, uma diminuição nas propriedades mecânicas dos adesivos ocorreu somente quando quantidades residuais de 9% foram simuladas. No entanto, pequenas quantidades de EtOH e CHX parecem não afetar as propriedades e velocidade de reação de polimerização dos adesivos / Abstract: The present study evaluates the influence of these solutions in different concentrations on flexural strength (FS), elastic modulus (E) and degree of conversion (DC) of conventional adhesives evaluating also the kinetic of conversion (K) and rate of polymerization (RP). Two distinct experiments were plotted, the first one evaluating the primer amount diluted in adhesives, and the second experiment evaluating rinse solutions amounts like water, ethanol and chlorexidine diluted in different adhesives. For different concentrations of primer solutions, two manipulated adhesives; M1 and M2 were tested at 0, 5, 10 and 15% of dilution. For different concentrations of water, ethanol (EtOH) and chlorexidine (CHX) dilutions, two adhesives were evaluated: M1, a manipulated adhesive, and the SBMP; diluted at 0, 2 and 9% of dilutions. Both studies, for mechanical properties, specimens were obtained by silicon mold bars (7 x 2 x 1mm), and after 24h, FS were performed at Mechanical Test Machine at cross speed of 0.5 mm/min. DC were measured with a Fourier Transformed Infrared Spectroscopy (FTIR). For K test, Infrared Spectroscopy monitored each 2 seconds of conversion for 60sec of polymerization, and the RP were evaluated. The first experiment, for different concentrations of primer dilutions, the FS for all adhesives tested was not affected by primer concentrations. All adhesives tested showed a decrease for DC as increased the primer dilution, with M2 presenting as the most sensitive for primer concentration. For second experiment, for all concentrations dilution of water, EtOH and CHX, a decrease on mechanical properties and DC was noted. Water and chlorexidine seems to affect more mechanical properties when compared to EtOH results. For K and RP results, increasing primer concentration, all adhesives presented a decrease of conversion and RP. For water dilutions, increasing water concentrations on tested adhesives, a progressive decrease could be noted on K graphics. CHX dilutions presented less influence on K, with decreasing RP and K only with 9% dilution. Although, EtOH dilutions presented an improve K as the RP, especially to SBMP adhesive. The results suggested that mechanical properties were not affected regardless of the primer amount diluted on adhesives, interfering only on chemistry of polymer reaction, once reaction speedy were affected (K and RP). However, for second experiment, a decrease on mechanical properties of adhesive solutions could be noted only when extreme amounts of residual solution where diluted. Notwithstanding, at lowest concentrations, EtOH and CHX seems not interfere on K and RP of adhesives / Doutorado / Dentística / Doutora em Clínica Odontológica
275

Efeito do condicionamento ácido adicional na resistência de união e Módulo de Weibull de sitemas adesivos aplicados em dentina sadia e afetada por cárie / Effect of additional acid etching on bond strength and Weibull modulus of adhesive systems applied on sound and affected dentin

Zanchi, Cesar Henrique 02 March 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1 Dissertacao_cesar_henrique_zanchi.pdf: 490684 bytes, checksum: 7c7bf328a3f694acdaf1aad686b90d1e (MD5) Previous issue date: 2007-03-02 / The aim of this study was to evaluate the effect of additional etching with phosphoric acid at 35% in the bond strength and Weibull modulus of two adhesive systems applied to sound and affected dentin. Ninety human molars with coronal carious lesion were sectioned to produce flat coronal superficies with effected dentin surrounded by sound dentin, and allocated in six experimental groups: SB-CT: Single Bond® applied to manufacture s instructions; SB+15: Single Bond® with additional etching for 15s; SB+30: Single Bond® with additional etching for 30s; CF-CT: Clearfil SE Bond® applied to manufacture s instructions; CF+15: Clearfil SE Bond® with additional etching for 15s; CF+30: Clearfil SE Bond® with additional etching for 30s. Afterwards, the crowns were built up with a composite resin and, after 24h, mesiondistal sectioned to produce 2 or 3 slices in each substratum. Thereafter (24h), the slices were trimmed in hourglass shape and submitted to micro-tensile test (n=30). The data were analyzed by three-way ANOVA, Tukey s test (p<0,05) and Weibull analysis. The bond strength to affected dentin was significantly lower than sound dentin for the adhesives systems employed, save SB+30. The additional etching increased the bond strength to affected dentin. To sound dentin, the additional etching increased the bond strength for Clearfil SE Bond®, but decreased for Single Bond®. The Weibull modulus to affected dentin was lower for both adhesives systems. On sound dentin, Single Bond® showed lower Weibull modulus than Clearfil SE Bond® and the additional etching decrease this value. Although the additional etching may increase the bond strength to affected dentin, the means were lower than sound dentin, the same for Weibull modulus. The additional etching may reduce the bond strength and Weibull modulus for Single Bond® to sound dentin and, in opposite, increase for Clearfil SE Bond® / O objetivo deste estudo foi avaliar o efeito do condicionamento adicional com ácido fosfórico à 35% na resistência de união e módulo de Weibull de dois sistemas adesivos aplicados em dentina sadia e afetada por cárie. Noventa molares humanos com lesão cariosa oclusal foram desgastados produzindo superfícies oclusais planas, com DAC circundada por DS, e divididos em seis grupos experimentais: SBCT: Single Bond® aplicado conforme o fabricante; SB+15: Single Bond® com condicionamento ácido adicional de 15s; SB+30: Single Bond® com condicionamento ácido adicional 30s; CF-CT: Clearfil SE Bond® aplicado conforme o fabricante; CF+15: Clearfil SE Bond® com condicionamento ácido adicional de 15s; CF+30: Clearfil SE Bond® com condicionamento ácido adicional de 30s. Após, as coroas dos dentes foram restauradas em formato de bloco e, posteriormente (24h), seccionadas no sentido mésio-distal originando 2-3 fatias em cada substrato. Após 24h as fatias foram recortadas em formato de ampulheta e submetidas ao ensaio de microtração (n=30). Os valores de resistência de união foram analisados com ANOVA (3- fatores), teste de Tukey (p<0,05) e análise de Weibull. Em geral, a resistência de união foi significantemente menor em dentina afetada por cárie que em dentina sadia para ambos os sistemas adesivos, exceto para SB+30. O condicionamento ácido adicional resultou no aumento da resistência de união em dentina afetada por cárie. Em dentina sadia o condicionamento ácido adicional aumentou a resistência de união para o sistema Clearfil SE Bond®, mas reduziu para o sistema Single Bond®. O módulo de Weibull foi menor em dentina afetada por cárie para os dois sistemas adesivos. Em dentina sadia, Single Bond® apresentou menor módulo de Weibull que Clearfil SE Bond® e o condicionamento ácido adicional resultou na redução desse valor. Embora o condicionamento ácido adicional possa aumentar a resistência de união em dentina afetada por cárie, as médias foram menores que em dentina sadia, bem como o módulo de Weibull. O condicionamento ácido adicional 11 pode reduzir a resistência de união e o módulo de Weibull para Single Bond® em dentina sadia e, contrariamente, aumentar para o sistema Clearfil SE Bond®
276

Avaliação da influência de métodos de descontaminação após contaminação com sangue em diferentes momentos do processo adesivo / Evaluation of the influence of decontamination methods after contamination with blood in different moments during the dentin adhesive process

Damé, Josiane Luzia Dias 23 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1 Dissertacao_joziane_luzia_dias_dame.pdf: 564053 bytes, checksum: dd7e96465f7bec29457bc90946463293 (MD5) Previous issue date: 2006-06-23 / Contamination while restoration procedures are carried out is mentioned in literature as a very frequent event, besides that, there are only a few papers which value this contamination influence in adhesion and possible decontamination methods to be carried out under such an occurrence. So, the aim of this study was to evaluate the influence of decontamination protocols upon dye leakage and push-out bond strength of a dentin adhesive system. It was used a hundred thirty five bovine incisors, which had their labial surface ground to obtain a flat dentine surface where standardized cylindrical cavities were made and they were divided in three groups: A) control without contamination (n = 15); B) contamination prior to the adhesive light activation (Adper Single Bond 2 3M ESPE) (n = 60) and C) contamination after the light activation (n = 60). After the contamination the cavities were divided (n = 15) according to the protocol used: 1) absorbent paper; 2) water; 3) conditioning with phosphoric acid or 4) sodium hypochlorite at 10%. The cavities were restored with the composite (Filtek Z250 3M ESPE), applied to only one increment. After 24 hours the restorations were polished and the specimens were subjected to thermal cycling (500 cycles/5o C a 55oC/30s). The exposure of the stained margins was done through the use of 2% methylene blue dye (pH = 7.0) and digital measurement of the restorations. The specimens cavity floor was ground, exposing the restoration, and they were submitted to the extrusion test (push out) in a universal testing machine. To statistics analysis it was used ANOVA according to two criteria (moment and protocol) and Tukey s test. In the marginal sealing evaluation there was significant statistics in the moment factor (p<0.001) and also in the interaction moment x protocol (p<0.008). The percentage average of stained margins found after light activation was statistically higher than the ones found prior to the light activation (p<0.001). In group B the conditioning protocol showed a percentage average of stained margins statistically higher than the water group (p<0.003), and the paper and hypochlorite groups demonstrated intermediate values. Comparing to group C protocols, it was not detected significant differences. Relating to the extrusion resistance, only the moment factor was statistically significant (p<0.001), while group B values were statistically higher (p<0.05) than the group C ones (5.32+3.03 and 3.4+1.92 MPa respectively). All protocols demonstrated resistance values similar to the control values. Higher resistance values were related to lower values of stained margins. It was concluded that blood contamination after light activation of the adhesive system had an adverse effect in the sealing ability of composite restorations and the different decontamination protocols generally produced similar results / A contaminação durante a realização de procedimentos restauradores é citada na literatura como um evento muito freqüente, apesar disso, poucos são os trabalhos que avaliam a influência desta contaminação na adesão e possíveis métodos de descontaminação a serem realizados frente a sua ocorrência. Assim, este trabalho teve como objetivo avaliar a influência dos métodos de descontaminação no selamento marginal e na resistência à extrusão de um sistema adesivo dentinário. Foram utilizados 135 incisivos bovinos, que tiveram a face vestibular desgastada expondo-se dentina, onde foram confeccionadas cavidades circulares padronizadas. Estas foram distribuídas em três grupos: A) controle, sem contaminação (n = 15); B) contaminação previamente à fotoativação do adesivo (Adper Single Bond 2 - 3M ESPE) (n = 60) e C) contaminação após a fotoativação (n = 60). Após a contaminação as cavidades foram divididas (n = 15) de acordo com o método utilizado: 1) papel absorvente; 2) água; 3) condicionamento com ácido fosfórico ou 4) hipoclorito de sódio a 10%. As cavidades foram restauradas com o compósito (Filtek Z250 - 3M ESPE), aplicando-se um único incremento. Após 24h as restaurações foram polidas e os espécimes submetidos à ciclagem térmica (500 ciclos/5°C a 55°C/30s). O selamento marginal foi avaliado utilizando-se o corante azul de metileno a 2% (pH = 7,0) seguido da digitalização das restaurações. Os espécimes foram desgastados pela face lingual expondo a restauração, e submetidos ao ensaio de extrusão (push out) em uma máquina de ensaios mecânicos. Para a análise estatística foram utilizados ANOVA segundo dois critérios (momento x método) e Teste de Tukey. Na avaliação do selamento marginal houve significância estatística para o fator momento (p<0,001) e também para interação momento X método (p=0,008). O nível médio de margens coradas encontradas após a fotoativação foi estatisticamente superior ao encontrado previamente a fotoativação (p<0,001). Dentro do Grupo B o método condicionamento demonstrou uma média de margens coradas estatisticamente superior ao grupo água (p<0,003), e os grupos papel e hipoclorito demonstraram valores intermediários. Para as comparações entre métodos dentro do Grupo C não foram detectadas diferenças significativas. Em relação à resistência à extrusão, apenas o fator momento demonstrou ser estatisticamente significante (p<0,001), sendo os valores do Grupo B estatisticamente superiores (p<0,05) aos do Grupo C (5,32±3,03 e 3,4±1,92 MPa respectivamente). Todos os métodos demonstraram valores de resistência similares ao controle. Maiores valores de resistência foram relacionados a menores valores de margens coradas. Concluiu-se que a contaminação com sangue após a fotoativação do sistema adesivo teve um efeito adverso na capacidade de selamento de restaurações de compósito e os diferentes métodos de descontaminação geralmente produziram resultados similares
277

CORRELAÇÃO ENTRE GRAU DE CONVERSÃO E RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES / CORRELATION BETWEEN DEGREE OF CONVERSION AND BOND STRENGTH OF THE SELF-ETCHING ADHESIVE SYSTEM

Borges, Marciano de Freitas 24 February 2010 (has links)
Objective: The aim of this study was to analyses the relationship between the degree of conversion of double bonds of self-etching adhesives and microshear bond strength on dentin. Materials and methods: For microshear testing twenty third molar caries free were selected. They had their crowns sectioned longitudinally so as to obtain slices that were randomly chosen and divided into four groups according to the adhesive system, Single Bond (SB), Clearfil SEBond (CL) , Adhese (AD) and Gbond (GB). The slices were included into epoxy resin, and then cylindrical restorations were built with an area of 1.0 mm in diameter and 2.0 mm in height, around ten restorations per group, using a starch matrix. After 24 hours the specimens were tested for bond strength. To analyze the degree of conversion of these systems, a drop of adhesive was dispensed on a glass plate and after 20 seconds polymerized, forming a film of adhesive. After 24 hours, these films were pulverized and mixed with potassium bromide, pressed in a hydraulic press to form an insert for analysis with the spectrophotometer - FT-IR. The data of shear bond strength and degree of conversion of each specimen were submitted to ANOVA and Tukey s test (p = 0.05). Results: The SB adhesive system had mean values of bond strength statistically higher than AD and GB, but no statistical difference was found with Cl. Among the self-etching systems, the highest average shear bond strength was achieved with the application of the union CL, followed by GB and AD systems, which were not statistically different. Regarding the degree of conversion, similar statistical results were found for the systems SB and CL, and despite the SB had a higher average it, did not differ from CL. The adhesive system SB and CL showed higher values in AD and GB. The AD, showed values higher than the GB. Conclusion: The degree of conversion is affected by several factors related to the complex mixture of adhesive systems, which somehow contribute to their bond strength. / Objetivo: O objetivo desse estudo foi avaliar o grau de conversão de sistemas adesivos autocondiconantes em dentina e correlacioná-los com a resistência ao teste de microcisalhamento. Materiais e Métodos: Para o ensaio de microcisalhamento foram selecionados vinte terceiros molares livres de cárie, os quais tiveram suas coroas seccionadas longitudinalmente de modo a se obter fatias, que, aleatoriamente, foram divididas em quatro grupos, de acordo com o sistema adesivo uilizado, Single Bond (SB), Clearfil SE Bond (CL), Adhese (AD) e Gbond (GB). As fatias foram incluídas em tubos de PVC com resina acrílica e, em seguida, foram construídas restaurações cilíndricas com uma área de 1,0 mm de diâmetro e 2,0 mm de altura, em torno de dez restaurações por grupo, por meio de uma matriz de amido. Após 24 horas, os corpos de prova foram submetidos ao ensaio de microcisalhamento. Para análise do grau de conversão desses sistemas, uma gota do adesivo foi dispensada sobre uma placa de vidro e, após 20 segundos, foram fotopolimerizadas, formando uma película de adesivo. Após 24h, essas películas foram pulverizadas e misturadas com brometo de potássio, prensadas em prensa hidráulica de modo a formar uma pastilha para análise no espectofotômetro - FT-IR. Os dados obtidos da resistência de união e do grau de conversão foram submetidos à análise de variância e teste de Tukey (p = 0.05). Resultados: O sistema de união SB apresentou valores médios de resistência de união ao microcisalhamento estatisticamente superior AD e GB, mas não apresentou diferença estatística em relação ao sistema Cl. Dentre os sistemas autocondicionantes, as maiores médias no ensaio mecânico foram obtidas com a aplicação do sistema de união CL, seguido pelos sistemas AD e GB, que não foram estatisticamente diferentes entre si. Em relação ao grau de conversão, resultados estatísticos semelhantes foram encontrados para os sistemas SB e CL, que, apesar do SB apresentar uma maior média, não diferiu do CL. O sistema adesivo SB e CL apresentaram valores médios superiores ao AD e GB. O AD, que por sua vez, apresentou valores médios maiores que o GB. Conclusão: O grau de conversão é afetado por diversos fatores relacionados à mistura complexa dos sistemas adesivos, que, de certo modo, repercutirá na sua resistência de união.
278

Influência da incorporação de antioxidantes em diferentes sistemas adesivos na resistência de união à dentina e nanoinfiltração / Influence of antioxidants incorporation into the different adhesive systems on dentin bond strength and nanoleakage

Gotti, Valéria Bisinoto, 1988- 22 August 2018 (has links)
Orientador: Américo Bortolazzo Correr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T02:50:31Z (GMT). No. of bitstreams: 1 Gotti_ValeriaBisinoto_M.pdf: 22569671 bytes, checksum: 63a18f68fe04710cbb552ebb07904779 (MD5) Previous issue date: 2013 / Resumo: O resumo poderá ser visualizado no texto completo da tese digital / Abstract: The abstract is available with the full electronic document / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
279

Efeito de diferentes modelos de envelhecimento na resistência de união em dentina decídua hígida e cariada / Different degradations models to evaluate bond strength in sound and caries primary dentin

Calvo, Ana Flávia Bissoto 04 March 2015 (has links)
A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00). O modelo in situ influenciou negativamente os valores de RU nos grupos RC e CIVMR (p<0,001) no substrato hígido e na RC (p<0,001), CIVMR (p=0,001) e CIVAV p=0,020) no substrato cariado. Concluí-se que no modelo in vitro, seis meses em água destilada não foram suficientes para degradar a interface de união dos materiais avaliados e o modelo in situ é uma metodologia rápida que pode ser utilizada para avaliar a degradação da interface de união de materiais restauradores em dentina cariada de dentes decíduo. / Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days. Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00). The in situ model, adversely, influenced the BS in RC and RMGIC groups (p <0.001) in sound substrate, and in RC (p <0.001), RMGIC (p = 0.001) and HVGIC (p = 0.020) in caries-affected dentin. We can concluded that in in vitro model, using six months distilled water, was not sufficient to degrade the bonded interface of the evaluated materials and in situ model is a faster method to evaluate degradation of the adhesion interface of restorative materials in cariesaffected dentin.
280

Efeito da irradiação com laser de diodo sobre adesivos dentinários / Effect of diode laser irradiation on dentin-bonding agents

Maenosono, Rafael Massunari 10 May 2017 (has links)
A irradiação de sistemas adesivos com laser tem obtido resultados promissores, no entanto, seu mecanismo de ação, bem como a longevidade da camada híbrida obtida após a irradiação com laser ainda não estão bem estabelecidos na literatura. A presente tese teve como objetivo: avaliar a absorvância do laser de Diodo por diferentes sistemas adesivos por meio de espectroscopia no infravermelho próximo; avaliar a evaporação de água e solventes proporcionada pelo laser por meio da variação da massa analisada em balança de precisão; avaliar a resistência de união por meio de teste de microtração após envelhecimento de 12 meses. Os dados obtidos foram analisados por modelos de ANOVA, seguidos de teste Tukey (p<0,05) e os resultados demonstraram que: a irradiação no infravermelho próximo, área do espectro eletromagnético que compreende o laser de Diodo, não apresenta interação com os sistemas adesivos testados; o laser de Diodo é capaz de proporcionar maior alteração de massa, mesmo após contínua evaporação dos solventes com jatos de ar por 60s; sistemas adesivos simplificados apresentaram valores de resistência de união imediato semelhantes aos valores obtidos após 12 meses de envelhecimento. Os dados obtidos neste estudo sugerem que a irradiação com laser de Diodo pode contribuir favoravelmente para a adesão em dentina com sistemas adesivos simplificados após 1 ano. / The laser irradiation of adhesive systems has obtained promising results, however, its mechanism of action, as well as the longevity of the hybrid layer obtained after laser irradiation are still not yet well established in the literature. This thesis aimed to: assess the diode laser interaction with different adhesive systems by means of near infrared spectroscopy; evaluate the evaporation of solvents and water provided by the laser through the mass variation analyzed at a precision balance; evaluate the bond strength through microtensile bond strength test after 12 months of aging. The data was analyzed through ANOVA models, followed by Tukey test (p<0.05), and the results demonstrated that: in the near-infrared irradiation area, the electromagnetic spectrum comprising the diode laser, shows no interaction with the adhesive systems tested; the diode laser was able to provide greater mass variation, even after continual evaporation of solvents with air jets for 60s; simplified adhesive systems presented immediate bond strength values similar to the ones verified after 12 months of aging. The data obtained in this study suggest that the Diode laser irradiation can contribute favorably for the adhesion between dentin and simplified adhesive systems after 1 year.

Page generated in 0.0783 seconds