• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Dureza da camada de adesivo e da camada híbrida e a sua relação com a resistência de união à dentina / Hardness of the adhesive layer and the hybrid layer and its relationship to bond strength to dentin

Nunes, Paula Mendes Acatauassú 02 September 2013 (has links)
Este estudo avaliou in vitro a dureza da camada de adesivo e da camada híbrida de uma interface entre resina composta e dentina humana por meio de ensaios de nanodureza (DUH). Foi avaliada a resistência de união por meio de testes de microcisalhamento (MC) com o objetivo de observar a relação desta resistência com a propriedade da dureza. Os fatores de variação compreendem quatro sistemas adesivos (Adper Scotchbond Multiuso, Adper Single Bond 2, Clearfil SE Bond e Single Bond Universal) e duas profundidades dentinárias (dentina rasa e dentina profunda). As unidades experimentais foram compostas por 144 fragmentos dentais obtidos da face vestibular de molares humanos, os quais foram distribuídos em 16 grupos, 8 grupos com n=6 para os ensaios de DUH e 8 grupos com n=12 para os ensaios de MC de forma que os quatro sistemas adesivos foram aplicados sobre fragmentos de dentina rasa e de dentina profunda. Após a confecção das restaurações em resina composta e 24h de armazenamento em estufa a 37°C, os ensaios de DUH foram realizados no ultramicrodurômetro DUH-211S (Shimadzu) com carga de 1mN/mseg. Os testes de MC foram realizados na máquina de ensaios universais Instron 5942(Instron Co) com velocidade de 1mm/min seguido da análise do padrão de fratura em microscópio digital. A análise estatística foi realizada por ANOVA (p<0,01%), Tukey e correlação de Pearson (p<0,05%). O sistema SB Universal (M=31,82±4,72) evidenciou os maiores valores de resistência de união e o Clearfil SE (M=26,75±3,73) os menores. O Single Bond 2 (M=28,83±4,07) e Scotchbond MP (M=28,53±4,61) não apresentaram diferenças entre si e obtiveram valores intermediários, não se diferenciando do maior e nem do menor valor. A resistência de união na dentina rasa (M=30,45±4,40) foi maior que em dentina profunda (M=27,52±4,01). Os sistemas SB Universal (M=22,57±2,42) e Scotchbond MP (M=22,13±2,89) não apresentaram diferença entre si e evidenciaram valores de dureza na camada de adesivo maiores que o Clearfil SE (M= 19,11±1,23). O sistema Single Bond 2 (M=20,11±1,49) apresentou valores intermediários de dureza e não foi diferente do maior e do menor valor. A camada híbrida em dentina rasa (M=38,23±3,08) apresentou maior dureza que a camada híbrida em dentina profunda (M=33,09±1,85). Pode-se concluir que tanto o sistema adesivo utilizado quanto a profundidade dentinária influenciaram nos resultados de resistência adesiva. A dureza da camada de adesivo varia conforme o sistema utilizado sendo que os adesivos SB Universal e o Scotchbond MP apresentaram os maiores valores de dureza. A dureza da camada híbrida foi influenciada pela profundidade dentinária do substrato. Foi observada uma correlação direta entre a dureza da camada de adesivo e a resistência adesiva. / This study evaluated in vitro the hardness of the adhesive layer and the hybrid layer interface between composite and human dentin using nanohardness test (DUH). Was evaluated the bond strength by microshear test (MC) in order to observe the relationship of this resistance with the hardness property. The variation factors consist of four adhesive systems (Adper Scotchbond Multi-Purpose, Adper Single Bond 2, Clearfil SE Bond and Single Bond Universal) and two dentin depths (superficial and deep dentin). The experimental units consisted of 144 dental fragments obtained from molars vestibular area, which were divided into 16 groups, 8 groups with n = 6 for DUH test and 8 groups with n = 12 for the MC test, so the four adhesive systems were applied on dentin fragments of superficial and deep dentin. After the construction of the composite resin restorations and 24h storage at 37 °C, DUH analysis were performed using a nanoindentation device DUH-211S (Shimadzu) with load of 1mN/mseg. The MC tests were performed in a universal testing machine Instron 5942 (Instron Co) with speed 1mm/min followed by analysis of the failure site in digital microscope. Statistical analysis was performed by ANOVA (p <0.01%), Tukey, and Pearson correlation (p <0.05%). The system SB Universal (M = 31.82 ± 4.72) showed higher values of bond strength and Clearfil SE (M = 26.75 ± 3.73) lower. The Single Bond 2 (M = 28.83 ± 4.07) and Scotchbond MP (M = 28.53 ± 4.61) did not differ among themselves and had intermediate values, not differentiating the largest and the smallest value. The bond strength of superficial dentin (M = 30.45 ± 4.40) was higher than in deep dentin (M = 27.52 ± 4.01.) Universal Systems SB (M = 22.57 ± 2.42) and Scotchbond MP (M = 22.13 ± 2.89) did not differ among themselves and showed hardness values in the adhesive layer higher than Clearfil SE (M = 19.11 ± 1.23.) The system Single Bond 2 (M = 20.11 ± 1.49) showed intermediate values of hardness and was not different from the largest and smallest value. The hybrid layer in superficial dentin (M = 38.23 ± 3.08) was harder than the hybrid layer in depth dentin (M = 33.09 ± 1.85.) It can be concluded that both the adhesive system used as the dentin depth influenced the bond strength. The hardness of the adhesive layer varies depending on the system used and the SB Universal adhesive and Scotchbond MP showed higher hardness values. The hardness of the hybrid layer was influenced by the depth of the dentin substrate. We observed a direct correlation between the hardness of the adhesive layer and the bond strength.
232

Resistência da união da cimentação adesiva de pinos de fibra de vidro frente ao teste de remoção por extrusão / Push-out bond strength of adhesive luted glass fiber posts

Silva, Luciana Mendonça da 24 March 2009 (has links)
Este trabalho avaliou a resistência de união de pinos de fibra de vidro cimentados à dentina com o uso de um cimento resinoso convencional e um auto-adesivo. Trinta dentes bovinos unirradiculares tiveram as raízes 17mm a partir dos ápices. As raizes foram tratadas endodonticamente e divididas aleatoriamente em 3 grupos (n=10): G1- cimento resinoso convencional RelyX ARC + ScotchBond Multi Uso Plus (SBMP) fotoativado + pino de fibra de vidro; G2 RelyX ARC + SBMP quimicamente ativado + pino de fibra de vidro; G3 cimento resinoso auto-adesivo RelyX U100 + pino de fibra de vidro. Após a cimentação dos pinos, os espécimes foram armazenados por 24 horas em água destilada, à 37oC. As raízes foram cortadas sob irrigação constante para obter de 6 a 9 fatias de 1mm de espessura. O teste de resistência à extrusão foi realizado para medir a resistência adesiva nas fatias da região cervical, média e apical, a uma velocidade de 0,5mm/min. Todos os espécimes foram observados em microscópio ótico de luz para avaliar os tipos de falhas. Os valores foram submetidos à análise de variância a dois critérios (ANOVA) e teste de Tukey (p0,05). As médias gerais dos grupos 1, 2 e 3, respectivamente, (MPa) foram de 4,87 (±3,65); 5,89(±3,72); e 8,50(±4,52). Os valores de resistência adesiva regional nos terços cervical, médio e radicular, respectivamente, foram: G1- 5,26(±3,44); 5,11(±3,33); 5,01(±3,17); G2- 7,45(±3,82); 5,88(±2,50); 4,91(±2,74); G3- 10,11(±3,11); 9,12(±3,70); 4,99(±3,28). Os maiores valores de resistência adesiva foram encontrados com o cimento auto-adesivo. Ao avaliar os terços separadamente, os grupos 2 e 3 obtiveram comportamento semelhante nos terços cervical e médio. No terço apical, todos os grupos tiveram o mesmo comportamento. A resistência de união foi influenciada pelo tipo de cimento utilizado e região radicular, mas não foi alterada pela variação do modo de polimerização do sistema adesivo. / This work evaluated the bond strength of glass fiber posts to dentin using a conventional and a self-adhesive resin cement. Thirty bovine incisors had their roots sectioned 17mm from their apices, endodontically treated and assigned into 3 groups (n=10): group 1, conventional resin cement RelyX ARC + ScotchBond Multi Purpose Plus (SBMP) light activated + glass fiber post; Group 2, RelyX ARC+ SBMP chemically activated + glass fiber post; Group 3, self-adhesive resin cement RelyX U100 + glass fiber post. After luting, specimens were stored for 24 hours in distilled water at 37oC. Roots were sliced under water irrigation to obtain 1mm thick slices. Push-out test was performed on each slice with a universal testing machine with a crosshead speed of 0,5mm/min. All fractured specimens were observed using a light microscope to identify modes of failure. Values were submitted to two-way ANOVA and Tukeys test (p0,05). Mean values (MPa) and standard deviation for groups 1, 2 and 3 were, respectively: 4.87 (±3.65); 5.89(±3.72); e 8.50(±4.52). Regional bond strength values for the cervical, medium and apical were: G1- 5.26(±3.44); 5.11(±3.33); 5.01(±3.17); G2- 7.45(±3.82); 5.88(±2.50); 4.91(±2.74); G3- 10.11(±3.11); 9.12(±3.70); 4.99(±3.28). The highest bond strength values were obtained using the self-adhesive cement. Regional bond strengths were similar in the cervical and medium region in groups 2 and 3. All cements had the same performance on the apical region. Bond strength was influenced by the type of cement used and radicular region, but was not altered by the activation mode of the bonding system.
233

"Desinfecção da Dentina Radicular pela Irradiação dos Lasers de Nd: YAG e Er: YAG: um Modelo "in vitro"" / Disinfection of intracanal dentin by ND:YAG, HO:YAG and ER:YAG laser irradiation: an in vitro model

Cecchini, Silvia Cristina Mafra 05 July 2001 (has links)
RESUMO Desinfecção da dentina radicular pela irradiação dos lasers de ND:YAG, HO:YAG e ER:YAG: um modelo in vitro A provável causa do insucesso da terapia endodôntica é a persistência de microrganismos colonizando os túbulos dentinários. Para reduzir o risco de insucesso e, se possível, o tempo despendido no tratamento endodôntico, novos equipamentos e materiais são constantemente desenvolvidos. O objetivo desta investigação foi estudar o efeito da irradiação laser intracanal na desinfecção dos túbulos dentinários de dentes bovinos recém-extraídos, utilizando-se um modelo in vitro. Os grupos irradiados pelos vários lasers foram comparados ao tratamento com hidróxido de cálcio, freqüentemente utilizado como medicação intracanal. O cemento radicular foi removido, o canal preparado e os dentes, cortados, resultando em 180 corpos de prova padronizados. Para promover a colonização bacteriana, os corpos de prova foram incubados, a 37 o C, em frascos contendo caldo de tripticase de soja e Enterococcus faecalis, o qual continha um plasmídeo que permitiu o seu crescimento em um meio seletivo com cloranfenicol. Os corpos de prova foram divididos em cinco grupos experimentais e três grupos-controle. Para irradiação foram utilizados os lasers pulsados de: Ho:YAG a 2,1 µm; Nd:YAG (1,06 µm); e Er:YAG (2,94 µm) com e sem refrigeração ar/água. Os grupos tratados receberam três parâmetros diferentes de irradiação com cada tipo de laser: energia abaixo do limiar de modificação física (physical modification threshold - ½ do PMT) por 60s; no limiar (PMT) por 60s; e, acima do limiar (120s). O Grupo 5 recebeu sete dias de tratamento com hidróxido de cálcio. Como controles, três espécimes para cada grupo receberam água estéril (controle negativo), três receberam KI3, após exposição à bactéria (controle negativo) e três não receberam tratamento após exposição à bactéria (controle positivo). A quantidade de bactérias foi estimada mediante a contagem de unidades formadoras de colônias (u.f.c.). De modo a avaliar, paralelamente, se os comprimentos de onda laser utilizados no experimento poderiam ser absorvidos pelo E. faecalis, foram obtidos espectros de absorção no UV, VIS e IR, por meio de espectroscopia. A análise estatística mostrou uma redução bacteriana como segue: Ho:YAG > hidróxido de cálcio > Nd:YAG > Er:YAG com refrigeração ar/água > Er:YAG sem refrigeração ar/água. Houve uma significativa redução bacteriana no grupo irradiado pelo Ho:YAG no limiar de modificação – PMT (50 mJ, 10 Hz, 66 J/cm 2 , por 120s), seguida pelo Ho:YAG a 50 mJ, 10 Hz, 33J/cm 2 , por 60s e pelo grupo que recebeu hidróxido de cálcio. Os dois últimos grupos não apresentaram diferenças estatísticas significativas. O espectro de absorção pelas bactérias (E. faecalis) nas faixas dos comprimentos de onda do UV e VIS apresentou picos de absorção em 361 nm e em 377 nm (UV). Já o infravermelho próximo revelou uma baixa absorção pelo microrganismo testado. / SUMMARY Disinfection of intracanal dentin by Nd:YAG, Ho:YAG and Er:YAG laser irradiation: an in vitro model A possible cause for root canal failure is the persistence of bacteria that have colonized dentinal tubules. To reduce this risk and, if possible, to also shorten the time-consuming endodontic therapy, new equipment and materials are constantly being introduced. The aim of the present investigation was to study the effect of disinfection of dentinal tubules by intracanal laser irradiation using an in vitro model. The groups irradiated by various lasers were compared with calcium hydroxide, a material frequently used as intracanal medication between appointments. Freshly extracted, intact bovine incisors were used. The root cementum was removed and the teeth cut to produce 180 standardized specimens. For bacterial colonization, specimens were incubated at 37 o C in test tubes with Tryptic Soy Broth and Enterococcus faecalis, which carried a plasmid that allowed the growth in a selective medium containing chloramphenicol. The specimens were divided in five treatment groups and three control groups. For irradiation, pulsed delivered Ho:YAG laser at 2.1 µm, Nd:YAG laser (1.06 µm), and Er:YAG and Er:YAG laser (2.94µm) with and without air/water coolant, were used. Lasers groups received three different laser settings for treatment: output energy below the physical modification threshold (½ of PMT) for 60 sec, at the PMT for 60 sec and above the PMT (120 sec). Group 5 received a seven-day treatment with calcium hydroxide. As controls, three specimens for each treatment group received sterile water instead of bacteria (negative control), three received iodine potassium-iodide after bacterial exposure (negative control), and three did not receive treatment after bacterial exposure (positive control). The number of bacteria was estimated by counting CFU. In order to evaluate whether the lasers used in the experiment could be absorbed by the bacteria E. faecalis, an UV, VIS and NIR spectra were obtained using a spectrophotometer. Statistical analysis showed the bacterial reduction as follow: Ho:YAG laser > hidróxido de cálcio> Nd:YAG laser > Er:YAG laser with air/water coolant > Er:YAG laser without air/water coolant. There was a significantly higher bacterial reduction in the group irradiated by the Ho:YAG at the PMT (50mJ, 10 Hz, 66 J/cm 2 for 120 sec), followed by Ho:YAG irradiated at 50mJ, 10 Hz, 33 J/cm 2 for 60 sec, and the group that received calcium hydroxide. The latter two groups were not significantly different. The UV and VIS absorbance spectrum presented two absorbance peaks at 361nm and 337nm (UV). The NIR spectrum revealed a very low absorbance by the E. faecalis.
234

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Agulhari, Maria Angelica Silverio 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).
235

Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-out

Tawil, Rosalyn Chidiak 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
236

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Morais, Renata Costa de 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
237

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Renata Costa de Morais 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
238

"Estudo da morfologia da interface de união em diferentes regiões de uma cavidade MOD" / A morphological study of the bonding interface in different areas of MOD cavities.

Moura, Sandra Kiss 12 June 2003 (has links)
RESUMO Esmalte e dentina são substratos dentários simultaneamente presentes na maioria das cavidades preparadas para restaurações adesivas, mas não há estudos sobre a morfologia regional das interfaces de união em uma mesma cavidade. Adesivos autocondicionantes incorporam a smear layer na camada híbrida e, conseqüentemente, as bactérias que porventura estejam presentes nela. Recentemente surgiu um adesivo autocondicionante com propriedades antibacterianas, conferidas pela adição de MDPB ao primer, mas ainda há poucas pesquisas sobre a morfologia da interface de união produzida por este material. Este estudo teve por objetivo analisar a morfologia de interfaces de união em diferentes regiões de cavidades MOD, através de microscopia eletrônica de varredura - MEV, em casos com adesivos autocondicionantes com ou sem MDPB. Como controle, foram usados dois adesivos de frasco único, cuja morfologia está amplamente descrita na literatura. Foram preparadas dezesseis cavidades Classe II em terceiros molares humanos hígidos, que foram restauradas com Z250 e um dos seguintes sistemas adesivos, aplicados segundo instruções dos fabricantes: ABF, Clearfil SE Bond, Single Bond e Prime & Bond NT. Após vinte e quatro horas de armazenamento em água destilada a 37ºC, os dentes restaurados foram seccionados em três planos de corte e preparados para análise em MEV, segundo o protocolo descrito por Montes et al. (2001). Também foram preparadas réplicas dos espécimes em resina epóxica. A morfologia das interfaces de união apresentou diferenças dependendo da região observada e também do tipo de sistema adesivo. A presença de MDPB não alterou a morfologia da interface de união dos adesivos autocondicionantes. A morfologia das interfaces de união em esmalte revelou perfeita adaptação ao substrato para todos os produtos estudados. / ABSTRACT Enamel and dentin are dental substrates simultaneously present in most cavity preparations for bonded restorations. Yet, no study can be found regarding the regional morphology of bonding interfaces present in a same cavity. Self-etching adhesive systems incorporate the smear layer into the formed hybrid layer, and consequently bacteria that might be present. Recently a self-etching system with antibacterial properties provided by the addition of MDPB was introduced in the market, but there is still little research on the interfacial morphology obtained with this material. This study aimed at analyzing the interfacial morphology in different areas of MOD cavities prepared using adhesive systems either with or without MDPB, by means of Scanning Electron Microscopy – SEM. Two single bottle adhesive systems whose morphology is widely described in the literature were used as control groups. Sixteen class II cavities were cut in sound human molars and restores using Z250 resin composite and one of the following adhesive systems, applied strictly according to the manufacturers’ instructions: ABF, Clearfil SE Bond, Single Bond and Prime & Bond NT. After 24-hour storage in distilled water at 37ºC, the teeth were sectioned in three directions and prepared for SEM analysis according to the protocol described by Montes et al. (2001). Replicas were also obtained from each specimen using epoxy resin. The interfacial morphology showed differences depending on the observed area, and also on the adhesive system. The presence of MDPB did not alter the interfacial morphology of the bonded interfaces obtained with self-etching adhesive systems. Bonded interfaces in enamel revealed perfect adaptation for all studied materials.
239

"Aspectos de micromorfologia, resistência de união e adaptação à dentina em função do tipo de adesivo e das características da camada de esfregaço" / Micromorphological aspects, bond strength and adaptation to dentin as a function of the type of the adhesive and the smear layer characteristics

Kenshima, Silvia 07 December 2005 (has links)
O objetivo do estudo foi avaliar o efeito de adesivos autocondicionantes com diferentes pHs aplicados em camadas de esfregaço (CE) fina e espessa na sua resistência de união (RU), adaptação marginal (AM) e micromorfologia. Foram utilizados 47 molares (n=5). A dentina oclusal foi exposta e cada dente foi seccionado em duas metades (unidade experimental) preparadas com lixa 600 (CE fina) e 60 (CE espessa). Os sistemas autocondicionantes foram selecionados conforme a acidez: Clearfil SE Bond (SE- fraco), Optibond Solo primer e adesivo (SO-intermediário), TYrian + One Step Plus (TY–forte). Um sistema convencional, ScotchBond Multi-Uso (MP) também foi estudado. A aplicação dos adesivos foi aleatória e uma reconstrução da porção coronária foi realizada com resina Z-250. Após 24h, os palitos para microtração (0,8mm 2 ) foram preparados. Parte deles foi submetida à microtração (Kratos–0,5mm/min). (Um índice de RU foi calculado levando-se em consideração a contribuição relativa dos tipos de fratura ocorridos). A outra parte foi avaliada em microscopia de luz (400x) quanto à AM tendo sido calculada a largura média de fendas (Lm) na interface de união. Para observação do padrão de condicionamento por MEV, os primers autocondicionantes e o H3PO4 foram aplicados à dentina tratada com lixa 60 e 600, removidos com banhos de álcool e acetona, fixados, desidratados com etanol, secos com HMDS e recobertos com ouro. Para observação dos prolongamentos resinosos, unidades experimentais “restauradas" com Z-250 tiveram a dentina removida com HCl e NaHOCl e as amostras recobertas com ouro. Os dados de RU e AM foram submetidos a ANOVA de 2 fatores (p=0,05). Testes de regressão (p=0,05) foram aplicados para RU e Lm e de cada um com o pH dos primers autocondicionantes. Apenas o fator Adesivo foi significante para RU e Lm e não houve relação entre ambos. Observou-se que TY apresentou RU significativamente inferior aos demais sistemas, semelhantes entre si. A Lm foi tanto maior quanto menor a acidez do sistema autocondicionante e MP apresentou a menor Lm. Em condições de CE espessa, as Lm foram significativamente maiores. Notou-se que o sistema de acidez fraca foi o mais afetado pela CE espessa tanto no padrão de condicionamento como na formação de prolongamentos resinosos. Houve maior remoção da CE com o sistema de acidez forte. Concluiu-se que, nas condições experimentais testadas, apenas o sistema convencional conseguiu aliar altos valores de resistência de união a uma boa adaptação marginal, e ainda reunir aspectos de micromorfologia compatíveis / The objective of this study was to evaluate the effect of different pH self-etch adhesives applied to thick and thin smear layer (SL) on bond strength (BS), marginal adaptation (MA) and micromorphology. 47 molars (n=5) were used. The occlusal dentin was exposed and each tooth was sectioned in two halves (experimental unit) prepared with 600-grit SiC paper (thin SL) and 60-grit (thick SL). The self-etch adhesives were selected according to the acidity: Clearfil SE Bond (SE-mild), Optibond Solo primer and adhesive (SO-intermediary), Tyrian + One Step Plus (TY– strong). An etch-&-rinse system, ScotchBond Multi-Purpose (MP) was also studied. The adhesives application was randomized and a resin composite build-up was made with Z-250. After 24h, the microtensile sticks (0.8 mm2) were prepared. Part of them was submitted to the microtensile bond strength test (Kratos-0.5 mm/min). (A BS index was calculated considering the relative contribution of the fracture types observed in the fractured sticks). The other part had the MA evaluated by light microscopy (400x) for the mean interfacial gap width (Gw) calculation. For the conditioning pattern SEM evaluation, the self-etch primers and the phosphoric acid was applied to dentin (60 and 600-grit), removed with baths of alcohol and acetone, fixed, dehydrated with ethanol, dried with HMDS and gold sputtered. For resin tags observation, restored experimental units were used. The dentin was removed with HCl and NaHOCl and gold sputtered. The BS and MA data was analyzed by 2-way ANOVA (p=0.05). The regression test (p=0.05) was performed for BS and Gw and for both with the self-etch primers pH. A regression test was applied for Gw and Li to evaluate their relationship (p=0.05). Only the Adhesive was significant for BS and Gw and no there was no relationship for them. TY presented significantly lower BS compared to the other adhesives that had similar BS. The higher the pH of the self-etch primers, the larger were the corresponding Gw (Gw x pH regression was significant). MP presented the lowest Gw. With thick SL, the Gw was significantly larger. The mild self-etch adhesive was affected by the thick SL in both the conditioning pattern and tags formation. The SL removal was more extensive with the strong self-etch. It was concluded that only the etch-&-rinse system achieved high BS and good MA with compatible micromorphological aspects
240

AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA

Sánchez-ayala, Alfonso 31 January 2008 (has links)
Made available in DSpace on 2017-07-24T19:21:56Z (GMT). No. of bitstreams: 1 Alfonso Sanchez-Ayala.pdf: 4109673 bytes, checksum: f08284c2e1c48354c9d9e417e1b9484e (MD5) Previous issue date: 2008-01-31 / The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive effectiveness when were submitted to thermal and mechanical stress. / A proposição deste estudo foi avaliar in vitro a efetividade adesiva em cavidades de classe V utilizando quatro diferentes sistemas adesivos, sendo submetidas a termociclagem e carga cíclica oclusal. As cavidades tiveram uma dimensão de 3x2x1.8 mm3 e foram realizadas na união amelo-cementária em vestibular e lingual de 80 pré-molares humanos (n=160). Os sistemas adesivos empregados foram Adper Single Bond 2, AdheSE, Adper Prompt L-Pop e One Coat 7.0. A resina composta utilizada foi Synergy D6. Os procedimentos de adesão e fotopolomerização (600 mW/cm2) foram realizados convencionalmente e seguindo as recomendações do fabricante. Os espécimes foram divididos em 4 grupos (n=40) segundo o tipo sistema adesivo utilizado. Cada grupo foi dividido em 4 subgrupos (n=10) segundo o tipo de estresse aplicado (termociclagem, carga cíclica oclusal e termociclagem+carga cíclica oclusal). Cada subgrupo incluiu 1 grupo controle sem estresse. A termociclagem foi realizada utilizando 500 ciclos a 5-55 C, 15 seg de tempo de permanência em cada temperatura e 5 seg de tempo de transferência. A carga cíclica oclusal foi realizada aplicando uma força de 40-70 N durante 50000 ciclos com freqüência de 2 Hz. Posteriormente, os espécimes foram impermeabilizados e imersos em agente traçador de solução a 50 de nitrato de prata por 2 horas. Finalmente, os espécimes foram preparados para a avaliação da efetividade adesiva por meio de microscopia óptica 40X (ocorrência de microinfiltração marginal) e microscopia eletrônica de varredura 1000x (formação de fendas). A microinfiltração do agente traçador foi mensurada qualitativa (escore) e quantitativamente . A largura das fendas foi medida (μm) em 3 pontos do centro da parede axial. Os testes de Kruskal-Wallis e post-hoc de Dunn, e ANOVA two-way e post-hoc Bonferroni foram utilizados na análise estatística. Apesar das poucas diferenças significativas encontradas no desempenho dos sistemas adesivos utilizados, pôde-se observar a tendência ao aumento da microinfiltração marginal nos grupos submetidos especificamente a termociclagem. Por outro lado, a formação de fendas axiais apresentaram progressivamente maior largura nos grupos submetidos a termociclagem, carga cíclica e termociclagem+carga cíclica. Concluise que os sistemas adesivos avaliados apresentaram efetividade adesiva similar quando foram submetidos a estresse térmico e mecânico.

Page generated in 0.103 seconds