Spelling suggestions: "subject:"diagn?stica por imagem"" "subject:"diagn?ético por imagem""
1 |
Avalia??o da qualidade de imagens adquiridas em c?mara dedicada a estudos card?acos com detectores de estado s?lidoFavero, Mariana Saibt 30 August 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-11-25T11:27:41Z
No. of bitstreams: 1
DIS_MARIANA_SAIBT_FAVERO_COMPLETO.pdf: 3636118 bytes, checksum: 2c3042f7c1e83bede7896f413417764c (MD5) / Made available in DSpace on 2016-11-25T11:27:41Z (GMT). No. of bitstreams: 1
DIS_MARIANA_SAIBT_FAVERO_COMPLETO.pdf: 3636118 bytes, checksum: 2c3042f7c1e83bede7896f413417764c (MD5)
Previous issue date: 2016-08-30 / Myocardial Perfusion Imaging (MPI) used in nuclear cardiology have been widely applied in clinical practice, because its value is documented in the diagnosis and prognosis of coronary artery disease. Due to the increasing use, the industry has developed projects for dedicated cardiac chambers that restrict the detection area just to the heart. Two detection systems for tomographic acquisitions in nuclear cardiology, using solid-state detectors, specifically cadmium zinc telluride crystals (CZT) are currently marketed. Although resulting in a short acquisition time and reduced radiation dose to the patient, there are doubts about the assessment procedures of equipment performance and the influence of the acquisition parameters and processing quality of the images. The aim of this study is to assess the impacts of changes in acquisition parameters and processing as cardiac SPECT equipment with solid and stationary gantry detectors. For this evaluation have been acquired images of an anthropomorphic experimental simulator with heart insert into a SPECT camera with solid state CZT detector type, to evaluate the quality and visibility of injuries. The images obtained were evaluated by quantitative quality indicators, such as the standard deviation normalization, contrast between the wall of the ventricle and the cavity, contrast-to-noise ratio and effective contrast of the lesion. As a result of the survey, variations in the time of acquisition does not affect the quality indicators values, unlike the reconstruction parameters and administered activity. The reconstruction parameter is what most affects the indicators, it is necessary to define a protocol of acquisition value for each activity to be administered in accordance with the characteristics of the patient. / Imagens de Perfus?o Mioc?rdica (MPI) usadas em cardiologia nuclear t?m sido amplamente aplicadas na pr?tica cl?nica, pois seu valor est? documentado no diagn?stico e progn?stico de doen?a arterial coronariana. Devido ao crescente uso, a ind?stria tem desenvolvido projetos para c?maras card?acas dedicadas que restringem a ?rea de detec??o apenas para o cora??o. Dois sistemas de detec??o para aquisi??es tomogr?ficas em cardiologia nuclear, utilizando detectores do estado s?lido, mais especificamente cristais de telureto de c?dmio e zinco (CZT) s?o comercializados atualmente. Apesar de resultarem em um curto tempo de aquisi??o e redu??o da dose de radia??o no paciente, existem d?vidas sobre os procedimentos de avalia??o do desempenho do equipamento e a influ?ncia dos par?metros de aquisi??o e processamento na qualidade das imagens. O objetivo desse trabalho ? avaliar os impactos de mudan?as de par?metros de aquisi??o e processamento na qualidade de imagens card?acas em equipamentos SPECT com detectores de estado s?lido e gantry estacion?rio. Para esta avalia??o foram adquiridas imagens de um simulador experimental antropom?rfico com inser??o card?aca em uma c?mara SPECT com detector de estado s?lido do tipo CZT, visando avaliar a qualidade e visibilidade de les?es. As imagens adquiridas foram avaliadas por meio de indicadores quantitativos de qualidade, como a normaliza??o do desvio padr?o, contraste entre a parede do ventr?culo e a cavidade, raz?o contraste-ru?do e contraste efetivo da les?o. Como resultado da pesquisa foi poss?vel observar que varia??es no tempo de aquisi??o n?o afetam os valores de indicadores de qualidade, diferentemente dos par?metros de reconstru??o e atividade administrada. O par?metro de reconstru??o ? o que mais afeta os indicadores, sendo necess?rio definir um protocolo de aquisi??o para cada valor de atividade a ser administrada de acordo com as caracter?sticas do paciente.
|
2 |
Gera??o de imagens para a quantifica??o das les?es de esclerose m?ltipla com exames de resson?ncia magn?tica do c?rebro humano utilizado no protocolo de rotina da pr?tica cl?nicaFarias, Fabiano Ricardo 23 April 2014 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-04-17T14:25:56Z
No. of bitstreams: 1
466589 - Texto Completo.pdf: 6603586 bytes, checksum: feeeb8bf10a13d97208972c59696bbb3 (MD5) / Made available in DSpace on 2015-04-17T14:25:56Z (GMT). No. of bitstreams: 1
466589 - Texto Completo.pdf: 6603586 bytes, checksum: feeeb8bf10a13d97208972c59696bbb3 (MD5)
Previous issue date: 2014-04-23 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The images, which correspond to slices in MRIs are part of the protocols used to aid in the diagnosis of multiple sclerosis and have lesions that characterize the disease. Among existing protocols, are the routine protocol and protocol specific for the disease being evaluated. The MRI scan of the specific protocol is an expensive and time-consuming test, but presents a more accurate quantification of volumetric lesion in the brain. The MRI scan of the routine protocol is an inexpensive routine examination; however, its accuracy is lower for quantifying the volume of multiple sclerosis lesions, due to the fact that it has a lower amount of data. Within this context, this dissertation presents the application of interpolation methods to generate artificial images through the images on the MRI scan of the routine protocol in order to simulate the images of the specific protocol for multiple sclerosis. At the end, an approach is presented that aims to improve the precision obtained with the interpolation techniques used to increase the reliability of volumetric lesion generated by interpolations. / As imagens, que correspondem ? cortes em exames de resson?ncia magn?tica, fazem parte dos protocolos utilizados para o aux?lio no diagn?stico da esclerose m?ltipla e apresentam as les?es que caracterizam a doen?a. Dentre os protocolos existentes, est?o o protocolo de rotina e o protocolo espec?fico para a doen?a que est? sendo avaliada. O exame de resson?ncia magn?tica do protocolo espec?fico ? um exame caro e demorado, por?m apresenta uma quantifica??o mais precisa da volumetria das les?es no c?rebro. O exame de resson?ncia magn?tica do protocolo de rotina ? um exame barato, entretanto, sua precis?o ? menor para a quantifica??o do volume de les?es de esclerose m?ltipla, devido ao fato de possuir uma quantidade inferior de dados. Dentro desse contexto, o presente trabalho apresenta a aplica??o de m?todos de interpola??o para gerar imagens artificiais, atrav?s das imagens presentes no exame de resson?ncia magn?tica do protocolo de rotina com o objetivo de simular as imagens contidas no exame do protocolo espec?fico para a esclerose m?ltipla. Ao final, ? apresentada uma abordagem que visa melhorar a precis?o obtida com as t?cnicas de interpola??o utilizadas, visando aumentar a confiabilidade da volumetria de les?es geradas pelas interpola??es.
|
3 |
Contribui??o da ultrassonografia como exame complementar no estabelecimento do diagn?stico de les?es nodulares submucosas e subcut?neas da regi?o bucomaxilofacialMartins, Felipe Leal 28 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:32Z (GMT). No. of bitstreams: 1
458174.pdf: 2019891 bytes, checksum: 013a15691fc2a263cbf3a31bd88ed1a8 (MD5)
Previous issue date: 2014-03-28 / Ultrasonography is an innocuous noninvasive diagnostic tool, which is easy to perform and low-cost, and it is widely used in the medical field, indicated especially in the exam of soft tissues. Despite this, it is not usually requested by dental surgeons in the diagnostic investigation of intraoral lesions. The aim of this study was to determine how much this resource contributes to establishing the final diagnosis of nodules located in the oral and maxillofacial region. Accordingly, we evaluated the indication of use and reliability of the procedure in Dentistry, considering the usefulness to reach the definitive diagnosis of these alterations. Sixty-five patients with submucosal or subcutaneous nodules were recruited for the study. They had been indicated for and subjected to regional ultrasonography, since it was not possible to establish a conclusive diagnosis of the lesions only by clinical examination. Ultrasonography was carried out in an imaging diagnostic center utilizing the same apparatus Toshiba Aplio 80 Japan. The imaging reports were prepared by a single examiner, with wide experience in the interpretation of images of the oral and maxillofacial region. Of the total patients, 43 had a biopsy for histopathologic confirmation of the final diagnosis. In 22 individuals, it was not necessary to perform surgery, since imaging allowed the establishment of the diagnosis and management of the patient. Two investigators evaluated the results obtained with ultrasonography and estimated the scores, which were zero (ultrasonographic diagnosis differed from the final), 1 (contributed to the management of the patient) and 2 (defined the definitive diagnosis). The zero score accounted for 12.3% of the examinations performed, while 41.5 and 46,1% of patients had scores of 1 and 2, respectively, totaling 87.6% of cases where imaging was helpful. The procedure facilitated the diagnosis of vascular lesions in 93.3%, helped with the management of 87.5% of patients with both malignant and benign neoplasms, and had a role in establishing the final diagnosis in 76.5% of cases of mucus retention phenomena. The results obtained were in accordance to findings in the literature, which demonstrated that ultrasonography is an effective resource in determining the final diagnosis or in the management of patients with nonspecific nodular lesions in the soft tissues of the oral and maxillofacial region / A ultrassonografia ? uma ferramenta de diagn?stico in?cua, n?o invasiva, de f?cil acesso e baixo custo utilizada amplamente na ?rea m?dica, indicada, em especial, no exame dos tecidos moles. Apesar disto, n?o costuma ser solicitada pelos cirurgi?es dentistas, durante a investiga??o diagn?stica de les?es intraorais. O objetivo desta pesquisa foi verificar o grau de contribui??o que o recurso fornece no estabelecimento do diagn?stico final de n?dulos localizados na regi?o bucomaxilofacial. Buscou-se estabelecer a indica??o de uso e confiabilidade do m?todo na ?rea da Odontologia, considerando a possibilidade do mesmo favorecer ou n?o o diagn?stico conclusivo destas altera??es. Foram selecionados 65 pacientes portadores de n?dulos submucosos ou subcut?neos, que tiveram a indica??o e foram submetidos ? ultrassonografia regional, uma vez que n?o foi poss?vel estabelecer o diagn?stico conclusivo das les?es exclusivamente atrav?s do exame cl?nico. A ultrassonografia foi realizada em um centro de diagn?stico por imagem utilizando o aparelho Toshiba Japan modelo Aplio 80. Os laudos foram emitidos por um ?nico examinador, com ampla experi?ncia na interpreta??o de imagens da regi?o bucomaxilofacial. Do total de pacientes, 43 foram submetidos ? bi?psia tendo o exame histopatol?gico para confirma??o do diagn?stico final. Em 22 indiv?duos n?o foi necess?ria a execu??o do procedimento cir?rgico, uma vez que o exame de imagem permitiu o estabelecimento do diagn?stico e manejo do paciente. Dois pesquisadores avaliaram os resultados obtidos na ultrassonografia e estabeleceram escores, que variaram entre zero (onde significou que o diagn?stico ultrassonogr?fico diferiu do final), 1 (contribuiu no manejo do paciente) e 2 (definiu o diagn?stico conclusivo). O escore zero, representou 12,3% dos exames realizados, entretanto os escores 1 e 2 computaram respectivamente 41,5% e 46,1%, totalizando um percentual de contribui??o equivalente ? 87,6%. O m?todo favoreceu o diagn?stico das les?es vasculares em 93,3% e no manejo das neoplasias, tanto malignas quanto benignas, em 87,5%. Nos fen?menos de reten??o de muco participou no estabelecimento do diagn?stico final em 76,5%. Os resultados obtidos foram ao encontro dos achados na literatura, os quais demonstraram que a ultrassonografia ? um recurso eficaz na determina??o do diagn?stico final ou no manejo dos pacientes, portadores de les?es nodulares inespec?ficas dos tecidos moles da regi?o bucomaxilofacial.
|
4 |
Altera??es hepatobiliares em gatos dom?sticos (Felis catus domesticus) parasitados por Platynosomum illiciens (Braun, 1901) Kossack, 1910 observadas atrav?s do exame radiogr?fico, ultra-sonogr?fico e de tomografia computadorizada. / Hepatobiliary changes in domestic cats (Felis catus domesticus) infected by Platynosomum illiciens (Braun, 1901) Kossack, 1910 observed through radiography, ultrasound and computed tomography.Azevedo, Felipe Delorme 26 February 2008 (has links)
Made available in DSpace on 2016-04-28T20:18:29Z (GMT). No. of bitstreams: 1
2008- Felipe Delorme Azevedo.pdf: 2096564 bytes, checksum: df01d12b66d119d793607a54f49e8ea9 (MD5)
Previous issue date: 2008-02-26 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Platynosomum illiciens (Braun 1901) Kossack, 1910, considered by some authors as
synonymy of Platynosomum fastosum and Platynosomum concinnum, is the most important
trematode found in cats of tropical and subtropical areas, and its prevalence can reach up to
85%. In Brazil it was already found at different localities, but State of Rio de Janeiro is where
it presents a higher prevalence and could be found in 56% of the cats. Due to the P. illiciens
diagnosis is being done exclusively through the discovery of eggs of this parasite by fecal
examination, and this is considered being little sensible, it is necessary the study of
complementary tools of diagnosis for the parasite and the hepatic alterations possibly
determined by this parasite. Therefore, radiology, ultrasound and computed tomography were
used for the evaluation of alterations caused by P. illiciens in order to evidence alterations that
aid in the diagnosis of this parasitosis or even to evidenced major alterations caused by the
platynosomiasis. A triage was accomplished with 13 animals searching for the presence of P.
illiciens eggs in feces. Eight positive cats (61.54%) were found, and submitted to the proposed
image diagnosis technics, except for tomography which only seven animals were submitted.
The radiologic examination evidenced five animals with enlargement of the liver; one animal
was with a normal liver and in two animals the hepatic limits were not observed through the
x-ray. In ultrasound scanning, six animals was identified hepatomegaly and in regard of the
hepatic parenchyma only one animal presented this parameter altered. All the animals
presented normal hepatic vessels and in regard to the biliary ducts, only two animals
presented this parameter increased. Besides, the presence of the parasite can be evidenced in
one animal during the accomplishment of the ultrasound scanning. In tomography, six cats
were observed with enlargement of the liver and in regard to the other findings the results
were descriptive. Among the obtained results, it can be concluded that the radiologic study
just evaluate the liver size in a restricted way. The ultrasound scanning and computed
tomography were considered good diagnostic tools, evaluating with clarity the hepatic size,
the hepatic parenchyma, the configuration and width of biliary ducts, the gall bladder and the
hepatic vessels. / Platynosomum illiciens (Braun, 1901) Kossack, 1910, considerado por alguns autores como
sinon?mia de Platynosomum fastosum e Platynosomum concinnum, ? o mais importante
tremat?deo encontrado em gatos de ?reas tropicais e subtropicais, com preval?ncia que pode
chegar a 85%. No Brasil j? foi encontrado em diferentes localidades, mas o Estado do Rio de
Janeiro ? onde apresenta maior preval?ncia podendo ser encontrado em 56% dos gatos.
Devido ao diagn?stico de P. illiciens estar sendo feito exclusivamente atrav?s do achado de
ovos deste parasito no exame de fezes, e este ser considerado pouco sens?vel, se faz
necess?rio o estudo de meios complementares de diagn?stico do parasito e das poss?veis
altera??es hep?ticas determinadas por este. Portanto, o exame radiol?gico, ultra-sonogr?fico e
tomogr?fico foram utilizados na avalia??o das altera??es acarretadas pelo parasitismo por P.
illiciens a fim de evidenciar altera??es que auxiliassem no diagn?stico desta parasitose ou
mesmo evidenciar importantes altera??es causadas pela platinosom?ase. Foi realizada uma
triagem em 13 animais em busca de gatos positivos para a presen?a de ovos de P. illiciens nas
fezes. Foram encontrados oito gatos positivos (61,54%) os quais foram submetidos aos tr?s
exames de diagn?stico por imagem propostos, com exce??o do exame de tomografia no qual
apenas sete animais foram submetidos. O exame radiogr?fico evidenciou cinco animais com
aumento hep?tico, um animal normal e em dois animais n?o se conseguiu identificar os
limites hep?ticos atrav?s da radiografia. Na ultra-sonografia foi poss?vel identificar seis
animais com hepatomegalia e em rela??o ao par?nquima apenas um animal apresentou este
alterado. Todos os animais apresentaram os vasos hep?ticos normais e em rela??o ?s vias
biliares, apenas dois animais apresentaram este par?metro aumentado. Al?m disso, pode-se
evidenciar a presen?a do parasito em um animal durante a realiza??o da ultra-sonografia. Na
tomografia foram observados seis gatos com o f?gado aumentado e em rela??o aos outros
achados os resultados foram descritivos. Dentre os resultados obtidos, pode-se concluir que o
exame radiogr?fico serviu apenas para avaliar de forma restrita o tamanho hep?tico. A ultrasonografia
e a tomografia computadorizada se mostram como boas ferramentas de
diagn?stico, avaliando-se com clareza o tamanho hep?tico, o par?nquima hep?tico, a
conforma??o e a espessura das vias biliares, a ves?cula biliar al?m dos vasos hep?ticos.
|
5 |
Investiga??o dos par?metros dependentes do paciente para a otimiza??o da atividade administrada em exames de PET/CT com 18F-FDGMartini, J?lio C?sar 29 August 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-12-06T16:05:53Z
No. of bitstreams: 1
DIS_JULIO_CESAR_MARTINI_COMPLETO.pdf: 2066306 bytes, checksum: ac62f8de7f443732c71f76471192afd6 (MD5) / Made available in DSpace on 2016-12-06T16:05:53Z (GMT). No. of bitstreams: 1
DIS_JULIO_CESAR_MARTINI_COMPLETO.pdf: 2066306 bytes, checksum: ac62f8de7f443732c71f76471192afd6 (MD5)
Previous issue date: 2016-08-29 / Despite the activities administered to patients during Positron Emission Tomography (PET) scans are guided by methods and reference levels, in clinical practice there is a great discrepancy between these values. Current indications use dependent patient parameters (DPP), such as age and weight, without considering an assessment of the resulting image quality. The purpose of this study is to investigate how the anthropometric and physiological characteristics of patients influence the determination of 18F-FDG activity to be administered in PET/CT scans and image quality. Therefore, we conducted a preliminary study with three simulators of different diameters, representing patients with different sizes, with different values of activity concentration. Subsequently, we performed a retrospective study on a PET/CT image database acquired with 18F-FDG. Image quality indicators (NECR, and NECRN and SNRnorm) of the images of patients were determined for many PDP, namely: body weight, BMI, BSA, fat mass, mass-height ratio and equivalent diameter. The relationship between the administered activity, counts rates and the PDP, with image quality indicators were statistically evaluated. We concluded that the NECRN is the quality indicator which has the best correlation between the PDP, particularly with body mass and BMI. The image quality in can be estimated from the true coincidence events rate (TRUES) during PET/CT acquisition with 18F-FDG, due to the highly linear relationship with NECR for different body mass or BMI ranges, allowing the optimization of the administered activity based on the physical characteristics of the patient. / Apesar das atividades administradas a pacientes durante exames de Tomografia por Emiss?o de P?sitrons (PET) serem norteados por m?todos e n?veis de refer?ncia, na pr?tica cl?nica h? uma grande discrep?ncia entre esses valores. As indica??es atuais utilizam par?metros dependentes do paciente (PDP), como idade e peso, sem considerar uma avalia??o da qualidade da imagem obtida. A proposta deste trabalho ? investigar como as caracter?sticas antropom?tricas e fisiol?gicas dos pacientes influenciam na determina??o da atividade de 18F-FDG a ser administrada em exames de PET/CT e na qualidade das imagens. Para tanto, foi realizado um estudo preliminar com tr?s simuladores de diferentes di?metros, representando pacientes com tamanhos distintos, com valores distintos de concentra??o de atividade. Posteriormente, foi realizado um estudo retrospectivo em um banco de imagens de exames de PET/CT com 18F-FDG. Foram determinados indicadores de qualidade (NECR, NECRN e SNR) das imagens dos pacientes para diversos PDP, a saber: massa corporal, BMI, BSA, massa gorda, rela??o massa-altura e di?metro equivalente. Foram avaliadas estatisticamente as rela??es entre as atividades administradas, as taxas de contagens e os PDP, com os indicadores de qualidade da imagem. Conclui-se que a NECRN ? o indicador de qualidade que possui a melhor correla??o entre os PDP, particularmente com a massa corporal e o BMI. A qualidade da imagem pode ser estimada atrav?s da taxa de eventos de coincid?ncia verdadeira (TRUES) durante a aquisi??o das imagens de PET/CT com 18F-FDG, em virtude da rela??o altamente linear com o NECR para faixas distintas de massa corporal ou BMI, possibilitando a otimiza??o da atividade administrada em fun??o das caracter?sticas f?sicas do paciente.
|
6 |
Protocolo assistencial para pacientes submetidos a tomografia computadorizada / Assistance protocol for patients submitted to computed tomographyDiniz, Kessya Dantas 01 December 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-03-28T20:24:16Z
No. of bitstreams: 1
KessyaDantasDiniz_TESE.pdf: 11488560 bytes, checksum: c749f2ac40a688c78b0e6cbe40b8be53 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-03-29T23:20:22Z (GMT) No. of bitstreams: 1
KessyaDantasDiniz_TESE.pdf: 11488560 bytes, checksum: c749f2ac40a688c78b0e6cbe40b8be53 (MD5) / Made available in DSpace on 2017-03-29T23:20:22Z (GMT). No. of bitstreams: 1
KessyaDantasDiniz_TESE.pdf: 11488560 bytes, checksum: c749f2ac40a688c78b0e6cbe40b8be53 (MD5)
Previous issue date: 2016-12-01 / O protocolo assistencial caracteriza-se por ser um conjunto de informa??es apresentado de forma dinamizada, que proporciona o cuidado sistematizado, e tem como intuito avaliar de maneira uniformizada os fatores relacionados aos aspectos cl?nicos, epidemiol?gicos e assistenciais, corroborando para a qualidade de vida e seguran?a do paciente. Diante disso, a elabora??o de um protocolo assistencial multiprofissional no ?mbito do servi?o de tomografia computadorizada poder? contribuir para uma avalia??o cl?nica precisa. Este estudo teve como objetivo elaborar e validar um protocolo assistencial no setor de tomografia computadorizada. Trata-se de uma pesquisa metodol?gica com abordagem quantitativa, realizada em duas etapas: a primeira constou de uma revis?o integrativa de literatura que subsidiou a constru??o do protocolo; a segunda caracterizou-se pela valida??o de conte?do por meio de especialistas de diversas profiss?es utilizando a t?cnica Delphi. A pesquisa foi iniciada ap?s a aprova??o do CEP da Universidade Federal do Rio Grande do Norte com o Certificado de Apresenta??o para Aprecia??o ?tica (CAAE) n?. 41872215.7.0000.5537. A primeira etapa foi operacionalizada entre outubro e novembro de 2015, por meio da revis?o da literatura nas bases de dados MEDLINE, SCOPUS, WEB OF SCIENCE e CINAHL, com o cruzamento dos descritores controlados: Diagn?stico por Imagem; Seguran?a do paciente e Tomografia. A amostra foi constitu?da por 23 artigos. Os resultados foram organizados em tr?s categorias: otimiza??o, monitoramento, qualidade e prote??o em rela??o ?s doses de exposi??o ? radia??o; rea??es adversas e nefropatias relacionadas ao uso do contraste; cuidados de enfermagem, gest?o e casos espec?ficos. Para a segunda etapa, os especialistas foram selecionados por meio da Plataforma Lattes do Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPQ), para identificar profissionais de sa?de do Brasil que atuassem como especialistas do instrumento. A amostra foi de 54 especialistas tanto no Delphi 1 como para o Delphi 2. A an?lise estat?stica foi realizada utilizando-se ?ndices de alfa Cronbach, ?ndice de Validade de Conte?do (IVC) e o ?ndice Relativo (IRA). Na primeira etapa, Delphi 1 a m?dia do alfa de Cronbach e IRA foram superiores a 0,80, o IVC foi de 0,924. Na fase Delphi 2, o alfa de Cronbach chegou a 0,868, com IVC de 0,934. Realizou-se uma compara??o entre as fases Delphi 1 e 2, e em ambas a confiabilidade foi bastante satisfat?ria. Atrav?s do teste de Mann-Whitney, observaram-se evid?ncias de diferen?a estat?stica da fase Delphi 1 com a fase Delphi 2 nas dimens?es de utilidade/pertin?ncia, consist?ncia, clareza, atualiza??o, precis?o, sequ?ncia instrucional dos t?picos e na avalia??o geral, onde obteve-se melhor avalia??o na fase Delphi 2 nas vari?veis descritas acima. Assim, alcan?ou-se a validade do protocolo em seu conte?do. / The clinical protocol is characterized by being a set of information presented in a streamlined manner, which provides systematic care, and has as aim to evaluate in a standardized manner the factors related to clinical, epidemiological and supportive aspects, corroborating for the patient's quality of life and safety. At that, the preparation of a multi professional assistance protocol under the computed tomography service can contribute to an accurate clinical evaluation. This study aimed to prepare and validate a supportive protocol in the field of computed tomography. This is a methodological research with a quantitative approach, carried out in two stages: the first consisted of an integrative review of literature that subsidized the construction of the protocol; the second was characterized by the content validation through experts of various professions using the Delphi technique. The research was initiated after approval by the Ethics Committee in Research from the Federal University of Rio Grande do Norte, with the Presentation Certificate for Ethics Assessment CAAE N?. 41872215.7.0000.5537. The first phase was implemented between October and November of 2015, through literature review in the MEDLINE, Scopus, Web of Science and CINAHL databases, with a cross-check of the controlled descriptors: Diagnostic Imaging; Patient safety and Tomography. The sample consisted of 23 articles. The results were organized in three categories: optimization, monitoring, quality and protection in relation to radiation exposure doses; adverse reactions and kidney diseases related to the use of contrast; nursing care, management and specific cases. For the second phase, experts were selected through the Lattes platform of the National Scientific and Technological Development Council (CNPQ) to identify health professionals from Brazil who decided to act as experts. The sample was of 54 experts both in Delphi 1 as for Delphi 2. Statistical analysis was performed using Cronbach's alpha index, Content Validity index (CVI) and the Relative Index (ARI). In the first stage, Delphi 1 the average of Cronbach's alpha and IRA were over 0.80, the CVI was 0.924. In Delphi 2 phase, the Cronbach's alpha reached 0.868, with CVI of 0.934. A comparison was made between Delphi phases 1 and 2, and in both cases the reliability was satisfactory. Through the Mann-Whitney test, we observed evidence of statistical differences between Delphi phase 1 and phase 2 in the dimensions of utility/relevance, consistency, clarity, update, precision, instructional sequence of topics and general evaluation, where we obtained a better evaluation in the Delphi phase 2 variables described above. Thus, it was reached the validity of the protocol in this content.
|
7 |
Desenvolvimento de um m?todo de obten??o do radiof?rmaco macro-agregado de albumina para marca??o com 99mTC e aplica??o em medicina nuclearVidal , Salus Cardoso 18 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-26T13:22:56Z
No. of bitstreams: 1
467668 Texto Parcial.pdf: 567013 bytes, checksum: 1bc3ad00024849f7dae91336da6c5f16 (MD5) / Made available in DSpace on 2015-05-26T13:22:56Z (GMT). No. of bitstreams: 1
467668 Texto Parcial.pdf: 567013 bytes, checksum: 1bc3ad00024849f7dae91336da6c5f16 (MD5)
Previous issue date: 2015-03-18 / This work proposes a methodology to obtain the radiopharmaceutical Human Macro-Aggregate Albumin (MAA) for further labeling with the radioisotope technetium-99-metastable (99mTc) and use in diagnostic imaging. The method proposes a process improvement during the manufacturing process for the production of this radiopharmaceutical regarding the established procedures described in international bibliography. 99mTc-MAA is a indispensable radiopharmaceutical, especially for the diagnosis of lung diseases, allowing the evaluation of patient perfusion capacity. This work presents the studies designed to obtain a lyophilized, non-toxic, sterile and pyrogen-free pharmaceutical preparation for intravenous administration. The injectable product reconstituted was characterized by the uniformity of the particles in suspension in relation to the number and size of protein aggregates. The analysis of optical microscopy and scanning electron microscopy (SEM) to check the number and size of particles have showed that none of the aggregates had size larger than 150 microns, therefore, within the clinical application limit. The radiochemical assays demonstrated the production of a product with high radiochemical purity (RQP). The radiochemical characteristics presented by the marked product according to the international pharmacopoeial requirements (QRP > 90%) allowing its use for diagnostic imaging through the technique that uses scintigraphic evaluation of pulmonary perfusion in nuclear medicine by single-photon emission computed tomography (SPECT). / O presente trabalho prop?e uma metodologia para obten??o do radiof?rmaco Macro-Agregado de Soro Albumina Humano (MAA), para posterior marca??o deste com o radiois?topo tecn?cio-99-metaest?vel (99mTc) e, assim, seu uso em diagn?stico por imagem. O m?todo prop?e uma melhoria de processo, em processo, para a manufatura deste radiof?rmaco em rela??o aos processos j? descritos nos comp?ndios internacionais. O 99mTc-MAA ? um radiof?rmaco imprescind?vel, principalmente, para o diagn?stico de patologias pulmonares permitindo a avalia??o da capacidade de perfus?o do paciente. Neste trabalho s?o apresentados os estudos desenvolvidos para a obten??o de uma prepara??o farmac?utica liofilizada de natureza at?xica, est?ril e apirog?nica para administra??o endovenosa. O produto injet?vel reconstitu?do foi caracterizado pela uniformidade do particulado em suspens?o em rela??o ao n?mero e ao tamanho dos agregados proteicos. As an?lises de microscopia ?ptica e de microscopia eletr?nica de varredura (MEV) para verifica??o do tamanho e do n?mero de particulados demonstraram que nenhum dos agregados apresentou tamanho superior a 150 ?m, estando, portanto, dentro do limite m?ximo para aplica??o cl?nica. Os ensaios radioqu?micos demonstraram a produ??o de um produto com elevado grau de pureza radioqu?mica (PRQ). As caracter?sticas radioqu?micas apresentadas pelo produto marcado atendem aos requisitos descritos nas farmacopeias internacionais (PRQ > 90%) permitindo o seu emprego para o diagn?stico por imagem utilizando t?cnica de avalia??o cintilogr?fica pulmonar de perfus?o em medicina nuclear por meio da SPECT (tomografia computadorizada por emiss?o de f?ton ?nico).
|
8 |
Feature selection for neuroimaging applied to word-category identification in dyslexic childrenFroehlich, Caroline Seligman 26 February 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-08-10T20:11:34Z
No. of bitstreams: 1
473233 - Texto Completo.pdf: 3157211 bytes, checksum: 46d1f58d384ad33725fbb29ba8257582 (MD5) / Made available in DSpace on 2015-08-10T20:11:34Z (GMT). No. of bitstreams: 1
473233 - Texto Completo.pdf: 3157211 bytes, checksum: 46d1f58d384ad33725fbb29ba8257582 (MD5)
Previous issue date: 2015-02-26 / Dyslexia is a developmental reading disorder characterized by persistent difficulty to learn
how to read fluently despite normal cognitive abilities. It is a complex learning difficulty that is often hard to quantify. Traditional methods based on questionnaires are not only imprecise in quantifying dyslexia, they are also not very accurate in diagnosing it. Consequently, we aim to investigate the neural underpinnings of this reading disorder in children and teenagers, as part of a project that aims to unravel some of the neurological causes of dyslexia among children at preliteracy age. In this dissertation, we develop a study of brain activation within functional MRI scans taken when children carried out pseudo-word tasks. Our study expands recently developed machine learning-based techniques that identify which type of word the study participants were reading based solely on participant?s brain activation. Because such functional MRI data contains
about 30,000 voxels, we try several feature selection techniques for removing voxels that are not very helpful for the machine learning algorithm.This procedure is widely used for maximizing the machine learning algorithm accuracy, and some of these feature selection approaches allowed us to achieve very accurate results. / Dislexia ? um transtorno de aprendizagem de leitura caracterizado pela dificuldade persistente
de uma crian?a a aprender a ler fluentemente, mesmo apresentando outras habilidades
cognitivas normais. A dislexia ? uma dificuldade de aprendizado complexo e dif?cil de diagnosticar.
M?todos de diagnostico tradicionais, como question?rios, n?o s?o somente imprecisos em quantificar
a dislexia, como tamb?m tamb?m n?o s?o precisos no diagn?stico. Consequentemente, n?s
visamos investigar a base neural deste transtorno de leitura em crian?as e adolescentes, como parte
de um projeto que tem como objetivo desvendar algumas das causas neurol?gicas da dislexia entre
crian?as em alfabetiza??o. Nesta disserta??o, desenvolvemos um estudo da ativa??o do c?rebro
com o uso de exames de imagem de resson?ncia magn?tica (IRM) funcional coletados enquanto
as crian?as realizavam uma tarefa de pseudo-palavras. Este estudo amplia t?cnicas de aprendizado
de m?quina recentemente desenvolvidas que identificam que tipo de palavra os participantes de um
estudo estavam lendo, baseado somente em sua atividade neural. Como dados de IRM funcional
contem aproximadamente 30.000 voxels, neste trabalho experimentamos com algumas t?cnicas de
sele??o de features para remover voxels que n?o s?o relevantes para o algoritmo de aprendizado
de m?quina. Esse procedimento ? amplamente utilizado para maximizar a acur?cia do algoritmo, e
algumas abordagens de feature selection permitem atingir resultados muito precisos.
|
9 |
Influ?ncia da informa??o cl?nica na reprodutibilidade da interpreta??o de imagens por resson?ncia magn?tica da articula??o temporomandibularBisi, Maur?cio Andr? 17 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:53Z (GMT). No. of bitstreams: 1
430603.pdf: 8044498 bytes, checksum: 9bbde27c42dcd9235f5e7c110e567949 (MD5)
Previous issue date: 2011-03-17 / A obten??o do diagn?stico das disfun??es temporomandibulares (DTMs) se faz atrav?s de uma anamnese acurada e do uso de exames de imagem complementares. O objetivo deste estudo foi avaliar a influ?ncia da informa??o cl?nica na reprodutibilidade intra e interexaminadores na interpreta??o de imagens por resson?ncia magn?tica (IRM) da articula??o temporomandibular (ATM). Quarenta exames de resson?ncia magn?tica foram avaliados por sete especialistas em disfun??o temporomandibular e dor orofacial em tr?s momentos distintos. Na ?ltima avalia??o foi informado aos avaliadores os dados cl?nicos dos pacientes. A reprodutibilidade intra-examinador foi avaliada mediante utiliza??o da medida de concord?ncia Cohen s Kappa e, a concord?ncia interexaminadores, pelo teste de Friedman. A hipermobilidade articular foi a patologia que obteve maior concord?ncia (kappa 0,770) e a altera??o degenerativa no osso temporal foi a de menor concord?ncia (kappa 0,447) entre os examinadores. A informa??o cl?nica n?o teve influ?ncia na interpreta??o de imagens por IRM da ATM e n?o houve diferen?a estatisticamente significativa entre os avaliadores quanto a sua reprodutibilidade neste modelo de estudo.
|
10 |
Avalia??o das propriedades diagn?sticas de dispositivo de baixo custo de digitaliza??o de radiografias anal?gicasGodoy, Giltom Fontoura de 30 August 2011 (has links)
Made available in DSpace on 2015-04-14T13:32:52Z (GMT). No. of bitstreams: 1
434560.pdf: 312802 bytes, checksum: cc55cda57da799d28b7e5ed47e64e6c6 (MD5)
Previous issue date: 2011-08-30 / OBJETIVO : Avaliar as propriedades diagn?sticas da caixa digitalizadora de baixo custo de imagens radiol?gicas ( c?mara auxiliar ), mediante a compara??o dos resultados das an?lises das imagens digitais com os das imagens anal?gicas originais (padr?o de refer?ncia).MATERIAIS E M?TODO : Noventa radiografias de t?rax, obtidas mediante proje??o ?ntero-posterior (AP) de pacientes pedi?tricos, coletadas dentre os exames solicitados mensalmente nos hospitais S?o Lucas, Grupo Hospitalar Concei??o, Porto Alegre e Hospital Universit?rio de Santa Maria, RS, Brasil, foram digitalizadas com o aux?lio da caixa digitalizadora ( c?mara auxiliar ), usando-se c?mera fotogr?fica digital de baixo custo, de uso amador. Dois radiologistas pedi?tricos, independentes, avaliaram as radiografias anal?gicas originais (padr?o de refer?ncia) e as imagens digitais obtidas por meio da caixa digitalizadora, concentrando-se nos tr?s par?metros mais frequentemente encontrados em patologias respirat?rias agudas, a saber: consolida??o pneum?nica, infiltrado intersticial e transpar?ncia pulmonar normal. Das noventa radiografias selecionadas, trinta n?o possu?am altera??es, trinta apresentavam condensa??es pneum?nicas e trinta apresentavam infiltrados intersticiais.RESULTADOS : As imagens produzidas pela caixa digitalizadora permitem a realiza??o de diagn?sticos compar?veis aos obtidos mediante a an?lise das radiografias anal?gicas originais, observando-se boa concord?ncia nas an?lises feitas intra-observador (K > 0, 80) e, igualmente, boa entre - observadores (K = 0,60-0,80).CONCLUS?O : A caixa digitalizadora, ao auxiliar a produzir imagens digitais que apresentam boa concord?ncia diagn?stica com o filme radiol?gico, representa uma alternativa acess?vel e de baixo custo para uso em transmiss?o de imagens radiol?gicas, permitindo obter-se laudo remoto, ou segunda opini?o de radiologistas especializados, integrando o conceito de um sistema de telerradiologia.
|
Page generated in 0.348 seconds