• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 400
  • 400
  • 400
  • 200
  • 179
  • 91
  • 63
  • 61
  • 59
  • 54
  • 54
  • 49
  • 46
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Utilização da ultra-sonografia modo B e da tomografia computadorizada no estudo do encéfalo de cães adultos / B-mode ultrasonography and computed tomography in evaluation of mature dog\'s brain

Carla Aparecida Batista Lorigados 26 June 2008 (has links)
A ultra-sonografia foi o primeiro meio diagnóstico por imagem utilizado na investigação do encéfalo, mas foi substituído pela tomografia computadorizada na década de 70 e atualmente por outros métodos como a ressonância magnética. O exame ultra-sonográfico continua sendo empregado em pacientes pediátricos e em animais jovens, cujas fontanelas permanecem abertas, servindo como janela acústica. Contudo, sua utilização em animais adultos fica restrita, em parte pela barreira proporcionada pelos ossos do crânio. Este trabalho objetivou: avaliar a possibilidade da utilização da ultra-sonografia transcraniana em cães adultos; estabelecer um paralelo com as imagens tomográficas; correlacionar as imagens sonográficas e tomográficas com a anatomia e comparar as imagens ultrasonográficas do encéfalo obtidas com e sem a interposição dos ossos do crânio. Foram utilizados dez cadáveres de cães adultos. As imagens tomográficas foram adquiridas em cortes transversais e dorsais com espessura de 5 mm e igual incremento. As imagens ultra-sonográficas foram obtidas através dos ossos temporal e porção lateral do parietal, da região frontoparietal dorsal íntegra e após craniotomia e do forame magno, em cortes transversais, dorsais e sagitais. Nesse estudo foi possível obter imagens do encéfalo dos dez cães através dos ossos temporal e parietal, evidenciando-se o tecido cerebral, os ventrículos laterais, a fissura longitudinal, alguns sulcos cerebrais, o cerebelo, o tentório do cerebelo, a região do diencéfalo e do hipocampo. A ultra-sonografia realizada através da craniotomia mostrou um bom detalhamento das estruturas anatômicas, superior ao obtido com a interposição óssea e nas imagens tomográficas. Não houve formação de imagem pelo osso frontal íntegro. Foi possível a visibilização apenas do cerebelo pela janela proporcionada pelo forame magno. As imagens tomográficas permitiram a visibilização direta do tecido cerebral, dos ventrículos laterais, do tentório ósseo do cerebelo. Muitas outras estruturas foram identificadas a partir da topografia e da sua relação com estruturas adjacentes. Concluiu-se que é possível avaliar o encéfalo de animais adultos através da ultra-sonografia utilizando como janela acústica os ossos temporal e a porção lateral do parietal. Contudo, a resolução das imagens é inferior quando comparadas àquelas realizadas com a fontanela aberta ou em craniotomias. Embora a tomografia computadorizada seja um excelente método para obter imagens seccionais, sem sobreposição de estruturas e uma maior diferenciação entre os tecidos moles, várias estruturas não são visibilizadas diretamente. Conhecer previamente a anatomia da região estudada é um pré-requisito importante para a adequada interpretação dessas imagens. / Ultrasound was the first medical technology performed for diagnostic imaging of the brain, but in the 70\'s the computed tomography became accessible, and recently, magnetic resonance imaging. Ultrasound imaging of the brain can be performed through the fontanelles in young animals. However, its using in mature dogs is restrict by the barrier presented by the bones of the skull. The purposes of this study were: evaluate of using ultrasound imaging of the brain in mature dogs; compare ultrasound with computed tomography imaging; correlate ultrasound and computed tomography features with the anatomy; compare the brain ultrasound images performed through a transosseous window with ultrasound images performed through craniotomy. Ten postmortem mature dogs were examined. Computed tomography scaning was obtained in transversal and dorsal planes, section thickness of 5mm and 5 mm intervals. Ultrasound imaging was performed through the temporal and parietal bones, dorsal frontoparietal before and after craniotomy and the foramen magnum. The images were acquired in transversal, dorsal and sagittal planes. It was possible identified intracranial structures using ultrasound imaging through the temporal and parietal bones: brain, lateral ventricles, longitudinal fissure, some brain sulci, cerebellum, diencephalon and hippocampus. Ultrasound imaging of some structures through the craniotomy showed to be superior to ultrasound imaging through transosseous and computed tomography imaging. It was not possible to visualize the brain structures in ultrasound imaging through the frontal bone. Through the foramen magnum was observed only the cerebellum. Computed tomography imaging allow to visualize the brain tissue, lateral ventricles and osseous tentorium. Many other structures were identified based on the relationship to adjacent structures and their topography. It was concluded ultrasound imaging through temporal and lateral portion of parietal bones is avaluable radiologic technique. However, the images resoluation is inferior compared to the features obtained through the fontanelles or craniotomies. Computed tomography is an excellent radiologic technique. It produces sequential sections of the brain and it capable of discerning many different soft-tissues without superposition. However, some structures couldn\'t be directly visualize. The knowledge of anatomy of the brain is essential to avoid misinterpretation of the images.
202

Avaliação morfológica e angiográfica por tomografia computadorizada e ressonância magnética do círculo arterial do cérebro. / Morphologic and angiographic computer tomography and magnetic resonance imaging of arterial circle of the brain (Willis Polygon).

Neysa Aparecida Tinoco Regattieri 18 October 2012 (has links)
O círculo arterial do cérebro (CAC) é objeto de estudo desde os princípios da anatomia moderna e ao longo dos séculos documentado e classificado de várias maneiras. Recentemente o desenvolvimento dos métodos diagnósticos por imagem e de ultraestrutura abriram um novo leque nas possibilidades de investigação. Neste trabalho o CAC foi avaliado por meio de exames por angiotomografia computadorizada, por angiorressonância magnética, fotografias de peças anatômicas, histologia, microscopia eletrônica por varredura e por transmissão. Verificou-se na amostra que o CAC possui tendência a simetria. Os achados foram similares na comparação entre os métodos de diagnóstico por imagem, porém não demonstraram todos os achados dos espécimes anatômicos. A metodologia utilizada permitiu verificar que as camadas das paredes das diferentes artérias podem explicar parcialmente as diferenças nos achados entre os métodos de imagem e as peças anatômicas. Os dados aqui apresentados revestem-se de grande importância clínica e cirúrgica uma vez que o CAC é um elemento chave na circulação cerebral. / The Willis Polygon (WP) has been studied since the beginning of modern anatomy and documented and classified over the centuries in various ways. Recently the development of diagnostic imaging methods and ultra structure opened a new range of possibilities in the investigation. In this work the WP was assessed by computer tomography angiography examinations by magnetic resonance angiography, photographs of anatomical specimens, histology, scanning and transmission electron microscopy. It was found that the sample has a tendency to the WP symmetry. The findings were similar when comparing the methods of diagnostic imaging, but did not show all findings of anatomical specimens. The methodology has shown that the different layers of the walls of arteries may partly explain the differences in findings between imaging and anatomical parts. The data presented here are of great clinical and surgical importance, once the WP is a key element in the cerebral circulation.
203

Detecção de fraturas radiculares verticais em radiografias convencionais e digitais obtidas em três diferentes sistemas na presença e ausência de material intracanal / Detection of vertical root fractures in conventional and digital radiography obtained in three different systems in the presence and absence of intracanal materials

Nascimento, Helena Aguiar Ribeiro do, 1986- 24 August 2018 (has links)
Orientador: Deborah Queiroz de Freitas França / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:50:35Z (GMT). No. of bitstreams: 1 Nascimento_HelenaAguiarRibeirodo_M.pdf: 1294865 bytes, checksum: aad6a2937765cf9381c0d31a4575d026 (MD5) Previous issue date: 2014 / Resumo: O objetivo no presente estudo foi avaliar a detecção de fraturas radiculares verticais (FRVs) em radiografias convencionais (RCs) e obtidas em três sistemas digitais com diferentes condições intracanal. Foram utilizados 40 dentes humanos unirradiculares com as coroas seccionadas na junção cemento-esmalte. Em seguida, os dentes foram divididos em dois grupos com 20 dentes em cada: grupo controle sem fratura e grupo com FRV. As FRVs foram induzidas em uma máquina de ensaio universal. Após, todos os dentes foram posicionados individualmente no alvéolo de uma secção mandíbula humana seca. Foram obtidas imagens de todos os dentes de acordo com a condição intracanal: sem preenchimento, com guta-percha, com pino metálico e com pino de fibra de vidro. As imagens foram obtidas utilizando-se a técnica do paralelismo e três incidências (orto, mésio e distorradial), com filme convencional (Kodak), placas de armazenamento de fósforo (Digora Optime® e VistaScan®) e um sensor CMOS (SnapShot®). Todas as imagens foram avaliadas por cinco examinadores em uma escala de 5 pontos. Após trinta dias, 25% da amostra foi reavaliada. As reprodutibilidades intra e interexaminador foram avaliadas por meio do Teste Kappa ponderado. Foram calculados os valores de sensibilidade, especificidade, acurácia, valores preditivos positivo e negativo. A comparação das avaliações com o padrão-ouro foi obtida utilizando a área sob a curva ROC, comparadas por meio da análise de variância dois critérios com teste post-hoc de Tukey e nível de significância de 5%. As reprodutibilidades intra e interexaminador exibiram valores de moderado a substancial. Apenas a sensibilidade apresentou diferença significante entre as modalidades de imagem, com valores superiores para o SnapShot (53,3%) e VistaScan (46,0%), seguidos pela RC (41,0%) e Digora (37,5%). Ainda o sistema SnapShot (0,82) apresentou área sob a curva ROC maior que os demais (VistaScan: 0,70; Digora: 0,64; RC: 0,68) na presença do pino de fibra de vidro. Foi possível concluir que todas as modalidades de exame apresentaram um bom desempenho no diagnóstico de FRV na ausência de material intracanal e inferior na presença do pino metálico ou guta-percha. Na condição com pino de fibra de vidro, sistemas digitais com maiores resoluções devem ser preferidos / Abstract: This study aimed to evaluate the detection of vertical root fractures (VRFs) in conventional radiography (CR) and three digital systems in teeth with different intracanal condition. The sample consisted of forty single-rooted human teeth, in which the crowns were sliced at the cementoenamel junction. Then, the teeth were divided equally in two groups: control without fracture and root fracture. The VRFs were induced through a universal testing machine. After this process, all teeth were individually placed in a dry mandible. The images were obtained of all teeth according to the intracanal condition: no filling, gutta-percha, metal and fiberglass post. The images were obtained using the parallelism technique with three different horizontal angulations (ortho, mesial and distorradial) with conventional film (CF) (Kodak), two storage phosphor plates (Digora Optime® and VistaScan®) and one CMOS sensor system (SnapShot®). All images were evaluated by five examiners on a 5-point scale. After thirty days, 25% of the images were re-evaluated. The intra and interobserver reproducibility were calculated using the weighted-kappa test. Values of sensitivity, specificity, accuracy, positive and negative predictive values were calculated. The area under the ROC curve of all modalities in the presence of different intracanal materials was calculated and compared using the two-way analysis of variance (ANOVA) with post-hoc Tukey test and a significance level of 5%. The intra- and interobserver reproducibility values ranged from moderate to substantial. Only the sensitivity showed a significant difference between imaging modalities, with higher values for SnapShot (53,3%) and VistaScan (46,0%), followed by the CR (41,0%) and Digora (37,5%). Also SnapShot (0,82) had an area under the ROC curve greater than the others in the fiberglass post group (VistaScan: 0,70; Digora: 0,64; CR: 0,68). It was concluded that all imaging modalities had a good performance in the diagnosis of VRF in the absence of intracanal materials and lower in the presence of the metal post or gutta-percha. In the fiberglass post group, digital systems with higher resolution should be used / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
204

Análise de lesões na substância branca do cérebro a partir de imagens de ressonância magnética / Analysis of white matter lesions using magnetic resonance images

Bento, Mariana Pinheiro, 1988- 22 August 2018 (has links)
Orientadores: Roberto de Alencar Lotufo, Letícia Rittner / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-22T11:40:53Z (GMT). No. of bitstreams: 1 Bento_MarianaPinheiro_M.pdf: 1641774 bytes, checksum: d858472eabb82055f830588e8df12b77 (MD5) Previous issue date: 2013 / Resumo: Essa dissertação de mestrado propõe um método de análise de lesões na substância branca do cérebro afim de distinguir as regiões de interesse entre substância branca normal ou não-normal, tarefa denominada identificação de lesões, assim como distinguir diferentes tipos de lesões de acordo com sua etiologia: desmielinizante ou isquêmica, tarefa denominada classificação de lesões. O método combina a análise de textura com o uso de classificadores, como o Máquinas de vetores suporte (SVM), K-vizinhos mais próximos (kNN), Floresta de Caminhos Ótimos (OPF) e Análise Discriminante Linear (LDA). Experimentos realizados em dados reais de ressonância magnética do cérebro mostraram que o método proposto _e adequado para identificação e classificação de lesões no cérebro / Abstract: This dissertation proposes a method for brain white matter lesions analysis in order to distinguish regions of interest between normal and non-normal brain white matter, called lesion identification task, and also to distinguish different types of lesions based on their etiology: demyelinating or ischemic, called lesion classification task. The method combines texture analysis with the use of classifiers such as Support Vector Machine (SVM), k-Nearst Neighboor (kNN), Optimum Path Forest (OPF) and Linear Discriminant Analysis (LDA). Experiments using real brain MRI data have shown that the proposed method is suitable to identify and classify the brain lesions / Mestrado / Engenharia de Computação / Mestra em Engenharia Elétrica
205

Pneumoconioses : casuistica de 25 anos do atendimento ambulatorial do Hospital das Clinicas da Unicamp, de 1978 a 2003, em Campinas (SP)

Lido, Alessandro Vito 12 June 2004 (has links)
Orientador: Ericson Batagin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T10:27:03Z (GMT). No. of bitstreams: 1 Lido_AlessandroVito_M.pdf: 591520 bytes, checksum: 2689b2b924e9a05658e2ce48f82eb0f6 (MD5) Previous issue date: 2004 / Resumo: Os dados brasileiros sobre a epidemiologia das pneumoconioses são limitados; ainda não dispomos de informações suficientes para o dimensionamento desse problema em nosso país. A consolidação dos dados, que permitem avaliar os agravos à saúde e seus fatores intervenientes, é uma ferramenta fundamental para seu controle e a avaliação e para a elaboração de políticas de saúde, através da vigilância epidemiológica. Com o objetivo de estudarmos a demanda ambulatorial das pneumoconioses no Hospital das Clínicas da UNICAMP, realizamos um estudo descritivo baseado na análise de prontuários. Os critérios básicos de inclusão foram: diagnóstico de pneumoconiose; histórico ocupacional compatível; e um radiograma do tórax. Através do registro hospitalar, dos relatórios médicos emitidos pela Área de Saúde Ocupacional (do Departamento de Medicina Preventiva e Social da Faculdade de Ciências Médicas da UNICAMP) e da análise dos prontuários, foram obtidas as informações necessárias para a consolidação de um banco de dados. Detectamos um universo de 1.147 casos de pneumoconiose, diagnosticados no período de 1978 a 2003, sendo 1.075 (93,72 %) do sexo masculino e 72 (6,28 %) do sexo feminino, com média de idade de 47,9 ± 10,14 anos (mediana em 46,86) e tempo médio de exposição aos agentes causadores das pneumoconioses de 17,1 ± 8,4 anos. Quanto ao tabagismo, 634 (65,43 %) eram fumantes (21,93 ± 17,53 anos-maço), 335 (34,57 %) não fumavam e em 178 a informação não estava disponível. Quanto às queixas respiratórias, a dispnéia foi o sintoma mais freqüente (560 pacientes, ou 48,82 %), seguido por tosse (261, ou 22,76 %), catarro (182, ou 15,87 %) e chiado (168, ou 14,65 %). Foram identificados 1.061 (92,50 %) casos de silicose, 51 (4,45 %) de pneumoconiose por poeira mista, 15 (1,31 %) de asbestose, 13 (1,13 %) de pneumoconiose por rocha fosfática e 7 (0,61 %) de outras pneumoconioses (por carvão, grafite e metais duros). Os radiogramas foram classificados quanto à qualidade; em 1, foram 330 (28,77 %); 2, foram 293 (25,54 %); 3, foram 401 (34,96 %). Quanto à profusão, em profusão 1 foram 657 (57,28 %); 2, foram 339 (29,56 %); 3, foram 145 (12,64 %). Os radiogramas apresentavam diversas combinações de forma e tamanho; 192 deles foram classificados com grandes opacidades: A, 58; B, 72; C, 62. Foram realizadas análises comparativas entre o primeiro e o último radiograma do tórax dos pacientes que fizeram seguimento, para avaliação da progressão radiológica. Também foram comparados os radiogramas com tomografias computadorizadas de alta resolução do tórax (TCAR), para o estudo comparativo no diagnóstico das pneumoconioses. A demanda ambulatorial de pacientes com pneumoconiose no Hospital das Clínicas da UNICAMP, nos 25 anos de atendimento que cobrem o período de 1978 a 2003, é uma das mais expressivas do país. A silicose foi a pneumoconiose de maior ocorrência, entre esses pacientes, seguido da pneumoconiose por poeira mista, da asbestose e da pneumoconiose por rocha fosfática. Os pacientes com pneumoconiose são predominantemente ceramistas fundidores de louças sanitárias e estampadores de louça doméstica, procedentes dos municípios de Jundiaí e Pedreira, ambos no estado de São Paulo. Encontramos uma maior freqüência (780 pacientes, ou 68 %) com tempo de exposição a poeiras maior que 10 anos, caracterizando a predominância da forma crônica da doença. As pneumoconioses foram diagnosticadas predominantemente em pacientes com faixa etária entre 40 e 54 anos, caracterizando o acometimento de adultos em plena idade produtiva. A categoria 1 da profusão das opacidades foi a mais freqüente (ocorre em 657 radiogramas, ou 57,28 %), caracterizando predominância da forma simples da doença. Foram observadas progressões radiológicas, com aumento da categoria da profusão das opacidades em 18,55 %, e surgimento ou aumento do tamanho das grandes opacidades em 18,12 %. A relação entre os exames de imagem mostrou discordância entre o radiograma do tórax (padrão OIT) e a tomografia computadorizada de alta resolução (TCAR) para a definição do diagnóstico. A atualização e o aprimoramento do banco de dados foram consolidados através da inclusão de casos e do acréscimo de novas variáreis para o estudo das pneumoconioses / Abstract: The Brazilian data on pneumoconiosis epidemiology are limited, and we have not enough information for the measurement of such problem in our country yet. The data consolidation that allows the evaluation of the health hazard and its interposing factors is a fundamental tool to control, evaluate, and elaborate health politics, through epidemiological surveillance. In order to assess its occurrence, we carried out a descriptive study whose basic criteria of admission were the preceding data of occupational exposure to pneumoconiosis causing agents and the chest radiography. Through medical register, and reports from the Área de Saúde Ocupacional do Departamento de Medicina Preventiva e Social of the Faculdade de Ciências Médicas da UNICAMP, it was possible to accomplish the identification of all patients with pneumoconiosis diagnoses in the Hospital das Clínicas da UNICAMP. The necessary information for this survey was obtained from medical records and the interpretation of the radiological exams that were collected in standardized form, composing a database. It includes 1,147 cases of pneumoconiosis diagnosed from 1978 to 2003. There are in it 1,075 (93.72 %) male and 72 (6.28 %) female workers, and their average age and standard deviation are 47.9 ± 10.14 years (median in 46.86). The average period of exposure for pneumoconiosis was 17.1 ± 8.4 years. With regard to smoking, there were 634 smokers (65.43 %) with an average consumption of 21.93 ± 17.53 packs-year; 335 (34.57 %) did not smoke, and the information was not available in 178 records. Concerning the respiratory symptoms, dyspnea was the most frequent, occurring in 560 cases (48.82 %), and then cough (261 cases; 22.76 %), sputum (182 cases; 15.87 %), and sizzle (168 cases; 14.65 %). We found 1,061 (92.50 %) cases of silicosis, 51 (4.45 %) of mixed dust pneumoconiosis (on abrasive industry), 15 (1.31 %) of asbestosis, 13 (1.13 %) of phosphorite pneumoconiosis, and 7 (0.6 %) of mineral dust pneumoconiosis (coal, graphite, and hard metals). The chest radiographs with predominant profusion-1 were 657 (57.28 %), with 2-profusion were 339 (29.55 %), and with profusion-3 were 145 (12.64 %), in several combinations of shapes and sizes. We found 192 radiographs with large opacities; the A type were 58; B, 72; and C, 62. From those patients who have undergone a radiological attendance, we carried out a comparative analysis between the first and the last chest radiograph, for the progression assessment. We also compared the high-resolution computer-assisted tomography (HRCT), when available, with the chest radiograph to study the pneumoconiosis diagnosis. The ambulatory medical demand of pneumoconiosis patients at the Hospital das Clínicas da UNICAMP from 1978 to 2003 is one of the most relevant in the country. The silicosis was the pneumoconiosis with the greatest frequency, followed by mixed dust pneumoconiosis, asbestosis, and phosphorite pneumoconiosis. The patients with pneumoconiosis are predominantly workers of the ceramics industries located in the cities of Jundiaí and Pedreira, both at São Paulo state. We found 780 patients (68 %) who have undergone a period of exposure to dust longer than 10 years. The pneumoconioses were diagnosed in patients whose age was predominantly between 40 and 54; the disease attacks the workers when they are in their best productive condition. The category profusion-1 of opacity was the most frequent (57.28 % of the cases), predominating the simple form of the disease. Radiological progression was found in 18.55 % of the cases, which had an increase in profusion of small opacities, and 18.12 % developed large opacities. The relation among the radiological exams showed divergence between chest radiograph (ILO standard) and high-resolution computer-assisted tomography (HRCT) for the diagnosis definition. The updating and improvement of database were compiled through the inclusion of new variables / Mestrado / Saude Coletiva / Mestre em Saude Coletiva
206

Influência da variação da miliamperagem na qualidade da imagem por tomografia computadorizada de feixe cônico / Influence of milliamperage variation on cone-beam computerized tomography image quality

Vasconcelos, Taruska Ventorini, 1985- 22 August 2018 (has links)
Orientadores: Plauto Chrisptopher Aranha Watanabe, Deborah Queiroz de Freitas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T04:06:31Z (GMT). No. of bitstreams: 1 Vasconcelos_TaruskaVentorini_M.pdf: 4859018 bytes, checksum: c363a84d1cdfd032d7453c1b0626f663 (MD5) Previous issue date: 2013 / Resumo: Imagens por tomografia computadorizada de feixe cônico (TCFC) são frequentemente utilizadas; no entanto, seu uso envolve doses de radiação que não podem ser indiscriminadas. A redução da miliamperagem (mA) é um dos meios mais práticos para se reduzir a dose de radiação; porém, ainda não se sabe o efeito isolado de protocolos de baixa mA na qualidade das imagens, fundamental para uma correta análise dessas. Com isso, o objetivo desse estudo foi avaliar a influência da variação da miliamperagem na qualidade da imagem de TCFC de diferentes regiões ósseas de mandíbulas edêntulas. Os exames tomográficos foram realizados em oito mandíbulas secas, utilizando os diferentes valores de miliamperagem disponíveis (2, 4, 6,3, 8, 10, 12 e 15 mA), em um aparelho de tomografia computadorizada de feixe cônico (K9000, Kodak). Após a obtenção das imagens, os cortes parassagitais das regiões correspondentes às de incisivos, caninos, prémolars, 1º molares e 2º molares foram avaliados por três radiologistas, de duas maneiras. Inicialmente, foi realizada uma avaliação subjetiva da qualidade, na qual foi adotada uma escala de quatro pontos (0 a 3), de acordo com a visibilidade das estruturas; posteriormente, os avaliadores realizaram uma avaliação objetiva, através da obtenção de medidas nas imagens, as quais foram posteriormente comparadas com medidas obtidas diretamente nas mandíbulas. Vinte e cinco por cento das imagens foram reavaliadas pelos examinadores, após 30 dias, para avaliação da concordância intraexaminador. Os resultados intra e interexaminador variaram entre bom a muito bom para avaliação da qualidade da imagem e foram excelentes quando foram avaliadas as medidas. Após a aplicação do teste estatístico de Tukey, foi possível observar que existiu uma influência da corrente utilizada na qualidade da imagem; entretanto, essa influência foi limitada ao uso de mA baixas (2 e 4). Após a mA 6,3, as imagens apresentaram desempenho semelhante, demonstrando não haver associação linear entre aumento dessa e melhora da qualidade da imagem. As medidas da altura óssea não sofreram influência da mA utilizada; porém, as imagens obtidas com 6,3 mA apresentaram a menor diferença em relação às medidas reais. Assim, pôde-se concluir que a mA 6,3 apresenta um equilíbrio adequado entre dose de radiação e qualidade da imagem no aparelho avaliado, devendo assim ser utilizada, e que o uso de mA maiores deve ser evitado, uma vez que não resultaram em imagens de maior qualidade e, com isso, apresentariam maior dose de radiação sem benefícios para o paciente / Abstract: Despite cone beam computed tomography (CBCT) images are often used; this involves radiation doses that require attention. The milliamperage (mA) reduction is an easy way to reduce radiation dose; however, the isolated effect of low mA settings on image quality is not knowed. This study aimed to evaluate the milliamperage in the image quality of the CBCT in different edentulous bone regions. The examinations were done in eight dry mandibles with different milliamperage values (2, 4, 6.3, 8, 10, 12 and 15) using the KODAK 9000 CBCT unit. The cross-sectional slices of the incisive, canine, premolar, first and second molar were analyzed by three oral radiologists, in two ways. Initially, a subjective evaluation of the visibility of the anatomical structures was performed based on a four grade scale and, afterwards, an objective evaluation through bone height measurement, which was compared with the real measures obtained in the mandible. After 30 days, 25% of the sample was re-evaluated by the observers, in order to obtain the intraobserver reproducibility. The intra and interobserver values varied between good and very good for the image quality evaluation, and they were excellent when evaluating the measurements. The Tukey test showed the influence of the milliamperage in the image quality, but only in the lowest values (2 and 4). The other milliamperage values had a similar performance. The measurements of bone height were not influenced by milliamperage, but the images obtained with 6.3 mA showed the lowest difference compared to the real measurements. Thus, it was concluded that the 6.3 mA provides an appropriate balance between radiation dose and image quality, and therefore the use of higher milliamperage values should be avoided since it does not provide an improvement of the image quality and it uses higher radiation dose without any benefit for the patient / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
207

Reformatação curvilínea baseada em simplificação e costura de malhas / Curvilinear reformatting based on mesh simplification and zippering

Loos, Wallace Souza, 1989- 10 October 2014 (has links)
Orientador: Wu Shin-Ting / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T15:53:26Z (GMT). No. of bitstreams: 1 Loos_WallaceSouza_M.pdf: 21840648 bytes, checksum: 8bb81a3fcf4de4d44de658f543435dda (MD5) Previous issue date: 2014 / Resumo: A reformatação curvilínea é uma técnica computacional de exploração, portanto, não invasiva, que permite realizar cortes curvilíneos sobre as neuroimagens. Ela complementa as reformatações multiplanares na localização de displasia cortical focal, causa comumente associada a epilepsia refratária. Foi desenvolvido um algoritmo de reformatação curvilínea baseado em malhas de offset pelo nosso grupo de pesquisa. Dois problemas foram identificados no algoritmo: artefatos visuais e limitação da região a ser reformatada em áreas visíveis. Neste trabalho apresentamos soluções para contornar estes problemas. Mostramos que a causa dos artefatos são as auto-interseções locais e que um algoritmo de simplificação pode removê-las de forma eficiente sem comprometer a geometria de reformatação. Desenvolvemos um algoritmo de costura para juntar malhas obtidas em diferentes ângulos de vista numa única malha de corte. Desta forma, é possível realizar a reformatação simultânea nos dois hemisférios cerebrais propiciando um diagnóstico baseado em análise comparativa dos dois lados. Na implementação dos nossos algoritmos procuramos explorar as vantagens de uma estrutura de dados eficiente e do paralelismo das unidades de processamento gráfico (GPUs) para termos resultados em tempo interativo. Experimentos preliminares com as neuroimagens dos pacientes com crises epilépticas apontam que a ferramenta pode colaborar na identificação de lesões sutis / Abstract: Curvilinear Reformatting is a computational exploration technique, therefore noninvasive, that allows making curvilinear slices on 3D neuroimaging data. It complements multiplanar reformatting to find lesions of focal cortical dysplasia, a common cause of refractory epilepsy. Our research group has developed an algorithm for curvilinear reformatting based on offset meshes. Two problems were identified: visual artifacts and limitations of the visible area to be reformatted. In this work we presented two solutions to solve these problems. We show that the cause of the artifacts are the local self-intersections and that an simplification algorithm can remove them efficiently without compromising the geometry of reformatting. We developed an sewing algorithm to join meshes from different angles of view on a single mesh. In this way, it is possible to make the curvilinear reformatting in both hemispheres of the brain, providing a diagnosis based on comparative analysis of the two sides. In the implementation of our algorithms we tried to explore the advantages of efficient data structure and parallelism of graphic processor units (GPU) to achieve results at interactive rates. Preliminary results with neuroimages from patients with epileptic seizures indicate that the tool may collaborate in the finding of subtle lesions / Mestrado / Engenharia de Computação / Mestre em Engenharia Elétrica
208

Estudo dopplerfluxométrico renal de quatis (Nasua nasua, Linnaeus, 1766) de vida livre /

Inamassu, Letícia Rocha. January 2015 (has links)
Orientador: Maria Jaqueline Mamprim / Banca: Raquel Sartor Marcelino / Banca: Carlos Roberto Teixeira / Resumo: A população de quatis tem aumentado consideravelmente, principalmente em parques públicos, fato que aumenta a preocupação com relação a ocorrência das doenças de caráter zoonótico. Existem poucos relatos do emprego da ultrassonografia convencional e Doppler na avaliação renal desses animais, assim como auxilio no diagnóstico das doenças nessa espécie. Portanto, o trabalho teve por objetivo avaliar pela ultrassonografia convencional as características de ecogenicidade comparativa dos rins e detectar, ao exame Doppler, um perfil do índice de resistividade das artérias intrarrenais de quatis de vida livre, sob contenção química. Foram avaliados 17 quatis, 4 machos e 13 fêmeas. Uma correlação positiva foi observada entre o peso (2,5 até 9,3 Kg) e comprimento dos rins (2,73 a 4,07 cm). Todos os quatis apresentaram adequada definição e proporção córtico-medular, com córtex hiperecogênico em relação à medular, mantiveram a mesma relação de ecogenicidade entre parênquima esplênico, hepático e córtex renal que os observados em cães e gatos. Foi obtido o índice de resistividade (IR) das artérias intrarrenais, com média de 0,63 ± 0,06 (variando de 0,49 a 0,82) e com pressão arterial sistêmica (PAS) média de 94 mmHg, valores de IR superiores aos encontrados nos cães e gatos não sedados. Não foi observado correlação positiva entre a PAS e o IR intrarrenal nos animais submetidos a combinação de cetamina, xilazina e midazolam. O IR desses animais deverá ser mensurados com outras combinações químicas de anestésicos / Abstract: Coati's population has increased considerably, especially in public parks, which increases the concern about the occurrence of zoonotic diseases. There are few reports of the use of conventional and Doppler ultrasound in renal evaluation of these animals, as well as an aid in the disease diagnosis in this species. Therefore, the study aimed to assess by conventional ultrasound the characteristics of comparative echogenicity of the kidneys and to detect at Doppler examination, a profile of the resistivity index of intrarenal arteries of free ranging coatis under chemical restraint. Seventeen coatis, 4 males and 13 females, were evaluated. A positive correlation was observed between body weight (from 2.5 to 9.3 kg) and renal length (from 2.73 to 4.07cm). All coatis had adequate cortico-medullary definition and ratio, with a hyperechoic cortex relative to the medulla, maintaining the same echogenicity relationship between splenic and hepatic parenchyma and renal cortex than those observed in dogs and cats. The resistive index (RI) was obtained from the intrarenal arteries, averaging 0.62 ± 0.06 (range 0.49 to 0.71) and mean systemic arterial pressure (SAP) of 95.06 mmHg, a higher RI than those found in dogs and cats not sedated. There was no positive correlation between SAP and renal RI in the animals submitted to a combination of ketamine, xylazine and midazolam. The RI of these animals should be measured with other chemical combinations of anesthetics / Mestre
209

Angiografia coronária não-invasiva por meio de tomografia computadorizada: determinação da acurácia de sistema isotrópico com 32 colunas de detectores em pacientes com doença arterial coronariana avançada / Noninvasive coronary angiography by computed tomography: assessment of the accuracy of an isotropic system with 32 detector rows in patients with advanced coronary artery disease

Marco Aurelio Santos Cordeiro 11 July 2005 (has links)
A doença arterial coronária (DAC) avançada caracteriza-se pela presença de vasos calcificados e difusamente estenosados, o que reduz a acurácia da angiografia coronária não-invasiva por meio dos atuais aparelhos de tomografia computadorizada (CT) com 16 colunas de detectores (16-MDCTA). O principal objetivo deste estudo foi tentar demonstrar uma acurácia diagnóstica global de pelo menos 90% para a detecção de estenoses coronárias >= 50% em pacientes com DAC avançada e alta probabilidade de possuírem escores de cálcio coronário elevados, mediante a utilização de um sistema de CT com 32 colunas de detectores, todas capazes de adquirir simultaneamente cortes com 0,5 mm de espessura (32x0,5-MDCTA). Angiografias coronárias sincronizadas ao traçado de ECG foram obtidas por meio da 32x0,5-MDCTA (32 cortes de 0,5 mm, voxels isotrópicos de 0,35x0,35x0,35 mm³, rotação do gantry a 400 ms) em 30 pacientes consecutivos (25 do sexo masculino, com idade média igual a 59±13 anos e índice de massa corpórea médio de 26,2±4,9 Kg/m²) e portadores de DAC avançada. As principais artérias nativas, incluindo seus ramos de primeira ordem com diâmetro >= 1,5 mm bem como os enxertos coronários existentes, foram avaliados de forma independente quanto à presença de estenoses >= 50%. Os stents foram excluídos. As angiografias coronarianas convencionais (realizadas em média 18±12 dias antes das respectivas 32x0,5-MDCTAs) foram analisadas de maneira quantitativa (angiografia coronária quantitativa). A mediana do escore de cálcio de Agatston foi igual a 510 (variação entre 3 e 5066). A sensibilidade, a especificidade e os valores preditivos positivo e negativo para a detecção de estenoses >= 50% nas artérias coronárias nativas foram seguintes: 76% (29/38), 94% (190/202), 71% (29/41), e 96% (190/199), respectivamente. A acurácia diagnóstica global foi de 91% (219/240). Do total de vasos analisados, 20% (69/352) foram excluídos devido à existência de um dos seguintes artefatos: movimento, ruído e baixo realce do contraste radiológico isoladamente ou em conjunto (45/69 ou 65%), distorção da imagem secundária à presença de eletrodo de desfibrilador ou marcapasso (18/69 ou26%), e calcificação arterial excessiva (6/69 ou 9%). Conclui-se que a 32x0,5-MDCTA exclui com precisão as estenoses coronarianas >= 50% em pacientes com DAC avançada e escore de cálcio coronário elevado, com acurácia diagnóstica global de 91% / Advanced coronary artery disease (CAD) is characterized by calcified and diffusely stenotic vessels, hampering accuracy of noninvasive coronary angiography with current 16-detector computed tomography (CT) scanners. The main purpose of this study was to try to demonstrate an overall diagnostic accuracy of at least 90% for detection of coronary stenoses >= 50% by half-millimeter 32-detector CT angiography (32x0.5-MDCTA) in patients with advanced CAD and a high likelihood of having elevated coronary calcium scores. ECG-gated coronary 32x0.5-MDCTA (32x0.5 mm cross-sections, 0.35x0.35x0.35 mm³ isotropic voxels, 400 ms gantry rotation) was performed in 30 consecutive patients (25 male, 59±13 years-old, 26.2±4.9 Kg/m²) with advanced CAD. Major coronary arteries, including >=1.5-mm first order branches, and bypass grafts were independently evaluated for >= 50% stenoses. Stents were excluded. Conventional coronary angiography (performed on average 18±12 days before their corresponding 32x0.5-MDCTAs) was analyzed by quantitative coronary angiography. Median Agatston calcium score was 510 (3-5066 range). Sensitivity, specificity, positive and negative predictive values for detection of >= 50% stenoses in the native coronary arteries were: 76% (29/38), 94% (190/202), 71% (29/41), and 96% (190/199), respectively. Overall diagnostic accuracy was 91% (219/240). Twenty percent (69/352) of the vessels were excluded from the analysis due to one of the following artifacts: motion, noise, and low contrast enhancement isolated or in combination (45/69 or 65%), image distortion secondary to an ICD or pacemaker lead (18/69 or 26%), and severe arterial calcification (6/69 or 9%). We concluded that 32x0.5-MDCTA accurately excludes >= 50% coronary stenoses in patients with advanced CAD and high calcium scores, showing an overall diagnostic accuracy of 91%
210

Aspectos Doppler e elastográficos renal e esplênico na Leishmaniose visceral canina

Dadalto, Carmel Rezende January 2020 (has links)
Orientador: Maria Jaqueline Mamprim / Resumo: O diagnóstico da Leishmaniose visceral é complexo, devido à infinidade de sinais clínicos inespecíficos e por vezes os cães apresentam-se assintomáticos por longos períodos de incubação, contribuindo para a disseminação da doença. Com a finalidade de auxiliar o diagnóstico, o presente estudo tem por objetivo descrever alterações ultrassonográficas ao modo B, Doppler e elastográficos em rim e baço de cães soropositivos para LV. Foram avaliados ao exame ultrassonográfico rins de 33 animais naturalmente infectados por LV, sendo as alterações mais relevantes observadas: o aumento da ecogenicidade cortical (75,75%) e a perda da definição corticomedular (27,27%). O índice de resistividade apresentou-se elevado 0,70 e 0,71, para o rim esquerdo e direito, respectivamente. A dimetilarginina simétrica se mostrou elevada em apenas 12 animais. O escore elastográfico observado com maior frequência foi o dois, referente a tecidos de elasticidade intermediária, tendendo a macio. Também foram avaliados 36 baços de animais soropositivos, o sinal mais frequente foi a heterogeneidade do parênquima (77,77%) com áreas micronodulares hipoecogênicas (60,7%) e esplenomegalia (55,5%). O escore elastográfico esplênico mais observado foi o três, referente a tecidos de elasticidade intermediária tendendo a rígido. As alterações renais e esplênicas descritas no estudo devem ser inclusas como diagnóstico diferencial em cães provenientes de áreas endêmicas. / Abstract: The diagnosis of visceral Leishmaniasis is complex, due to the infinity of nonspecific clinical signs and dogs are often asymptomatic for long incubation periods, which may contribute to the spread of the disease. In order to help early diagnosis, the present study aims to describe sonographic mode B, Doppler and elastographic changes in kidney and spleen of VL seropositive dogs. Kidneys of 33 animals naturally infected with VL were evaluated by ultrasound examination. The most relevant changes were the increase in cortical echogenicity (75.75%) and the loss of corticomedullary definition (27.27%). The resistivity index remained high 0.70 and 0.71 for the left and right kidney respectively. Symmetric dimethylarginine was elevated in only 12 animals. The most frequently observed elastographic score was two, referring to tissues of intermediate elasticity. Thirty-six spleens from seropositive animals were also evaluated, the most frequent sign being parenchymal heterogeneity (77.77%) with hypoechogenic micronodular areas (60.7%), followed by splenomegaly (55.5%), and these changes could appear concomitant or not. The most observed splenic elastographic score was three (47.22%), referring to intermediate elasticity tissues tending to rigid. The renal and splenic changes described in the study should be included as differential diagnosis in dogs from endemic areas. / Doutor

Page generated in 0.1162 seconds